TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 652. UNDERGROUND INJECTION CONTROL

Similar documents
Tennessee Underground Injection Control Program Overview

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 205. HAZARDOUS WASTE MANAGEMENT

RULE 68. DISPOSAL OF NATURALLY OCCURRING RADIOACTIVE MATERIALS (NORM) ASSOCIATED WITH THE EXPLORATION AND PRODUCTION OF OIL AND GAS

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 616. INDUSTRIAL WASTEWATER SYSTEMS SUBCHAPTER 1. INTRODUCTION [AMENDED]

15A NCAC 02C.0225 GROUNDWATER REMEDIATION WELLS (a) Groundwater Remediation Wells are used to inject additives, treated groundwater, or ambient air

APPLICATION REVIEW CHECKLIST LAND PROTECTION DIVISION HAZARDOUS WASTE PROGRAM OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY TECHNICALLY ADMIN.

Proposed New 18 CFR Part Hydraulic Fracturing in Shale and Other Formations:

CHAPTER 39 REQUIREMENTS FOR PROPERLY PLUGGING ABANDONED WELLS

15A NCAC 02C.0219 AQUIFER STORAGE AND RECOVERY WELLS (a) Aquifer Storage and Recovery Wells are used to inject potable water for the purposes of

(B) "Facility," for the purposes of this rule, means:

Permit Number: 1900B Expiration Date: July 15, 2021

DEPARTMENT OF ENVIRONMENTAL QUALITY OIL, GAS, AND MINERALS DIVISION OIL AND GAS OPERATIONS. Filed with the Secretary of State on

SUBCHAPTER 1. INTRODUCTION

STATE OF ARKANSAS ARKANSAS POLLUTION CONTROL AND ECOLOGY. REGULATION NO. 17 Effective May 4, 1989 Arkansas Underground Injection Control Code

SUBCHAPTER 8. ADDITIONAL REQUIREMENTS FOR UNDERGROUND INJECTION CONTROL (UIC) PROGRAM

No An act relating to hydraulic fracturing wells for natural gas and oil production. (H.464)

CHAPTER 32 - WELL ABANDONMENT ORDINANCE OF DUBUQUE COUNTY, IOWA. Adopted September 5, Part 1 Introduction...2

SUBCHAPTER 8. This is a courtesy copy of this rule. All of the Department s rules are compiled in Title 7 of the New Jersey Administrative Code.

15A NCAC 13A.0109 STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES - PART 264 (a) Any person who

This document also includes proposed permit requirements, including response actions, when excursions occur.

Soil Improvement by Compaction Grouting

PUBLIC WATER SUPPLY WELLHEAD PROTECTION REGULATIONS

SUBSIDIARY LEGISLATION BOREHOLE DRILLING AND EXCAVATION WORKS WITHIN THE SATURATED ZONE REGULATIONS

DEPARTMENT OF ENVIRONMENTAL QUALITY WATER QUALITY DIVISION PERMIT APPLICATION FORM UNDERGROUND INJECTION CONTROL (UIC) CLASS V WELL

SUBCHAPTER 1. GENERAL PROVISIONS

Colorado Regulations Currently Impacting Impoundments

NAVAJO NATION UNDERGROUND INJECTION CONTROL REGULATIONS

Oil and Gas Fast Facts and Frequently Asked Questions February 19, 2013

NGWA s Water Well Construction Standard: ANSI/NGWA 01-14

HOLLEY NAVARRE WATER SYSTEM, INC. BACKFLOW PREVENTION & CROSS CONNECTION CONTROL POLICIES & REGULATIONS

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 624. MINOR PUBLIC WATER SUPPLY SYSTEMS

Injection Wells. An injection well is a vertical pipe in the ground into which water, other liquids, or gases are

TITLE 17. (b) Auxiliary Water Supply is any water supply other than that received from a public water system.

STATE OF COLORADO DIVISION OF WATER RESOURCES OFFICE OF THE STATE ENGINEER

Implementation of Underground Injection Control Program Regulations for Class V Shallow Disposal Systems

Part 4 CONSTRUCTION OF WELLS AND THE WITHDRAWAL OF GROUNDWATER Purpose. [Ord , -/-/2002, 1]

Environmental Management Chapter

Wastewater Capital Projects Management Standard Construction Specification

Understanding The Class II Underground Injection Control Application Process In Colorado To Comply Cost-Effectively

BROWARD COUNTY ENVIRONMENTAL PROTECTION DEPARTMENT (EPD) MINIMUM CRITERIA FOR MONITORING WELL INSTALLATION AND SAMPLING

HIGHLANDS WATER COMPANY Lakeshore Drive Clearlake, California {707}

Michigan Department of Environmental Quality Resource Management Division Office of Oil, Gas, and Minerals

TABLE OF CONTENTS PART III. REVISION 0 6-ii

Montana Department of Public Health and Human Services Food and Consumer Safety Section CIRCULAR FCS

NATIONAL ENERGY BOARD ONSHORE PIPELINE REGULATIONS

252: Definitions The following words and terms, when used in this Chapter, shall have the following meaning, unless the context clearly

SECTION RISK-BASED ASSESSMENT AND CORRECTIVE ACTION FOR NON-UST PETROLEUM RELEASES

Summary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources

SPECIAL SPECIFICATION 5989 Settlement Gauge

Mercer County Household Sewage Treatment System Regulations

California Groundwater Association An NGWA Affiliate State 700 R Street Suite 200 Sacramento, CA

SUBSURFACE ROTARY DRILLING INVESTIGATION SPECIFICATIONS

15A NCAC 02T.1501 is proposed for readoption without substantive changes as follows:

Appendix C. Table of Rainfall and Evaporation Data [REVOKED]

The Mineral Industry Environmental Protection Regulations

CONCENTRATE AND BRINE MANAGEMENT THROUGH DEEP WELL INJECTION. Abstract

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 631. PUBLIC WATER SUPPLY OPERATION SUBCHAPTER 1. INTRODUCTION

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 690. WATER QUALITY STANDARDS IMPLEMENTATION SUBCHAPTER 1. INTRODUCTION

GUIDELINES to the MINING ACT

Livingston County Department of Public Health Environmental Health Division. Hydrogeologic Investigation Requirements for Land Division Developments

Wayne Farms Ozark Feedmill

Environmental Management Chapter ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT WATER DIVISION - WATER QUALITY PROGRAM ADMINISTRATIVE CODE

ADMINISTRATION AND ENFORCEMENT OF THE COLORADO CHEMIGATION ACT

Wellhead Protection General Guidelines for New Private Domestic Wells

Rick Henderson, Field Operations Supervisor DEQ Office of Oil, Gas, and Minerals

Injection Wells for Liquid-Waste Disposal. Long-term reliability and environmental protection

#47 CASE STUDY INSTALLATION OF A SOIL-BENTONITE CUTOFF WALL THROUGH AN ABANDONED COAL MINE (GROVE CITY, PA)

UNOFFICIAL 785:35 Page 1 of 26 UNOFFICIAL TITLE 785. OKLAHOMA WATER RESOURCES BOARD CHAPTER 35. WELL DRILLER AND PUMP INSTALLER LICENSING

ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT WATER DIVISION- INDUSTRIAL SECTION

Dear Director Zehringer and Chief Simmers,

Craig Dufficy U.S. EPA Office of Resource Conservation and Recovery

Reclaimed Water Treatment, Distribution, Pumping and Storage Engineering Report Form

Environmental Protection and Marcellus Shale Well Development. Scott Perry Director Bureau of Oil and Gas Management

D.G.S.W. Pitakumbura Manager (Groundwater Studies) Groundwater Section NWS&DB. Groundwater recharge or deep drainage or

Annex A ENVIRONMENTAL PROTECTION PART I. DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTECTION OF NATURAL RESOURCES ARTICLE II.

Harris County Board of Health Rule For Governing Individual and Non-Public Water Wells

CONSTRUCTION RULES TABLE OF CONTENTS

OHIO ENVIRONMENTAL PROTECTION AGENCY L PE RMIT-TO4 N STALL t

General Groundwater Concepts

Detail on Concentrate Handling and Disposal Options

Appendix VIII. Guidelines for groundwater bores and wells

Geologic Sequestration Rules: A Multi-Stakeholder Perspective

EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE

7. Completing the Well s Structure

Fracturing Overview: Fact vs. Fiction Andy Bond, Subsurface Manager December 8,

Texas Commission on Environmental Quality Page 1 Chapter Industrial Solid Waste and Municipal Hazardous Waste

Background. AEM Tier 2 Worksheet Farmstead Water Supply Evaluation. AEM Principle: Glossary

Additional criteria for approval of sanitary landfill facility permit to install applications.

1. Introduction Site Information Site Characteristics Hydrogeologic Setting... 2

11.04 WELLHEAD PROTECTION ORDINANCE

(NOTE: Unless specifically identified, the changes outlined below apply to BOTH Chapter 78 and Chapter 78a.)

Current Regulatory Issues Impacting the Appalachian Basin. Gary E. Slagel Steptoe & Johnson PLLC October, 2014

TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 606. OKLAHOMA POLLUTANT DISCHARGE ELIMINATION SYSTEM (OPDES) STANDARDS

Chaparral Natural Resources, Inc.

Class III In Situ Uranium Injection Wells and Aquifer Exemptions in Texas: Multiple Levels of Permitting Protection for USDW Protection

CHEMUNG COUNTY SANITARY CODE ARTICLE V ONSITE WASTEWATER TREATMENT SYSTEMS (OWTS)

Westbay System. Multilevel Technology for Subsurface Characterization and Monitoring

Wellhead Protection General Guidelines for Existing Private Domestic Wells. Wellhead Protection Recommendations for Well Owners:

GAS WELL/WATER WELL SUBSURFACE CONTAMINATION

CITY OF HAMILTON Codified Ordinance CHAPTER 941

Transcription:

Codification through the 2016 legislative session. Subchapters 1, 3 and 11 Board adoption - June 16, 2015 Gubernatorial approval - June 9, 2016 Effective date - September 15, 2016 TITLE 252. DEPARTMENT OF ENVIRONMENTAL QUALITY CHAPTER 652. UNDERGROUND INJECTION CONTROL Subchapter 1. General Provisions... 252:652-1 3. Exclusionary Siting Criteria for Class I Wells... 252:652-3 5. Application Content Requirements... 252:652-5 7. Construction Requirements... 252:652-7 9. Additional Operating Requirements... 252:652-9 11. Class V Drinking Water Treatment Residual Wells... 252:652-11 1

252:652-1-1. Purpose 252:652-1-2. Applicability 252:652-1-3. Incorporation by reference 252:652-1-4. Zoning 252:652-1-5. Hazardous waste 252:652-1-6. Fees SUBCHAPTER 1. GENERAL PROVISIONS 252:652-1-1. Purpose The rules in this Chapter implement 27A O.S. 2-6-701. 252:652-1-2. Applicability Any person who owns or operates or proposes to own or operate any underground injection well facility, except those wells subject to the jurisdiction of the Oklahoma Corporation Commission, shall be subject to the rules in this Chapter. The terms "operating or proposing to operate" shall include proposed drilling and construction of new injection wells and conversions of existing injection wells. 252:652-1-3. Incorporation by reference (a) Code of Federal Regulations. When reference is made to Title 40 of the Code of Federal Regulations, it shall mean Procedures for Decision-Making and (unless otherwise specified) the Underground Injection Control Regulations, April 1, 1983, as amended through July 1, 2014. (b) 40 CFR incorporation. Title 40 CFR Parts 124 (Subpart A), 144, 145, 146, 147, 148 are incorporated in their entirety as they apply to the Underground Injection Control Program, excluding any regulations pertaining to Class VI wells. (c) Synonymous terms. For purposes of interfacing with 40 CFR Parts 124 (Subpart A) or 144-148, the following terms apply: (1) Administrator, Regional Administrator, and Director are synonymous with Executive Director. (2) State is synonymous with the Department of Environmental Quality (DEQ). (3) Public hearing is synonymous with public meeting. (d) Citations incorporated by reference. When a provision of the Code of Federal Regulations is incorporated by reference, all citations contained therein are also incorporated by reference. (e) Inconsistencies or duplications. If there are inconsistencies or duplications in the requirements of those provisions incorporated by reference and the rules in this Chapter, the federal provisions shall prevail, except where the rules in this Chapter are more stringent. However, the rules in this Chapter shall not relieve any person from complying with the minimum requirements found in this Chapter and Title 40 of the Code of Federal Regulations. 252:652-1-4. Zoning This Chapter shall not abrogate in any way the zoning authority of any duly constituted zoning agency with respect to the siting of any facility. 252:652-1-5. Hazardous waste The surface facilities of any Class I hazardous waste injection well shall be subject to the permitting, operating and fee regulations of OAC 252:205, Hazardous Waste Management. 2

252:652-1-6. Fees (a) Class I injection well facilities. (1) Permit application - $2,000. (2) Permit renewal - $500. (b) Class III injection well facilities. (1) Permit application - $2,000 (2) Permit renewal - $500 (c) Class V injection well facilities. [See 40 CFR 146.5(e)] (1) Permit application (A) Wells used for the injection of wastes into a subsurface formation - $2,000 (B) Others listed herein - $600 (i) Cooling water return flow wells used to inject water previously used for cooling, excluding air conditioning return flow wells used to return to the supply aquifer the water used for heating or cooling in a heat pump; (ii) Sand backfill and other backfill wells used to inject a mixture of water and sand, mill tailings or other solids into mined out portions of subsurface mines; (iii)wells used for solution mining of conventional mines such as stopes leaching; (iv) Injection wells used in experimental technologies; and (v) Injection wells used for in situ recovery of lignite, coal, tar sands and oil shale. (2) Permit renewal for facilities listed in (1)(A) and (1)(B) of this subsection - $100 SUBCHAPTER 3. EXCLUSIONARY SITING CRITERIA FOR CLASS I WELLS 252:652-3-1. Siting criteria 252:652-3-1. Siting criteria The following rules shall apply to owners and operators of all Class I wells: (1) Groundwater resources and recharge areas. Except as otherwise provided by Title 27A O.S. 2-7-111, no permit for a proposed new site shall be granted for a Class I injection well facility to be located over or through an unconsolidated alluvial aquifer or terrace deposit aquifer, or over or through a bedrock aquifer. Site-specific hydrological and geological information which demonstrates that the proposed location does not lie in a prohibited area may be provided by an applicant. The DEQ may require site-specific hydrological and geological information for a facility proposed to be located outside a designated principal groundwater aquifer or recharge area where there is reason to believe the proposed location may be unsuitable due to localized groundwater conditions. Sources used to determine if a site is unpermittable are the "Map of Aquifers and Recharge Areas in Oklahoma", compiled by Kenneth S. Johnson, Oklahoma Geological Survey (1991), and the Oklahoma Water Resources Board rules codified at OAC 785:45 Appendices A through D, inclusively, or any successor map(s) to these sources. (2) Water wells. No permit shall be granted for a new Class I injection well facility proposed to be located within 1320 feet (one-quarter statute mile) of any public or private water supply well. Provided, however, that existing or proposed private water supply wells located on the applicant's property may be exempt from this paragraph at the applicant's discretion. Where proximity of a Class I facility to water supply well(s) is in doubt, a survey shall be conducted by an Oklahoma licensed land surveyor to determine actual distances. (3) Flood plain. No new Class I injection well facility shall be permitted in the 100 year flood plain unless the 100 year flood plain is subsequently redefined to not include the land area proposed for the new disposal area. 3

(4) Surface water. No permit shall be granted for a new Class I injection well facility proposed to be located within the established conservation pool elevation of any reservoir which supplies water for a public water supply. SUBCHAPTER 5. APPLICATION CONTENT REQUIREMENTS 252:652-5-1. Class I injection well facilities 252:652-5-2. Class III injection well facilities 252:652-5-3. Class V injection well facilities 252:652-5-1. Class I injection well facilities The following shall be included in an application for a permit for any Class I injection well facility: (1) Map. Public records which verify the information regarding all producing wells, water wells and dry holes submitted on the map required by 40 CFR 146.14(a)(2) or 146.70(a)(2). See also 40 CFR 144.55 and 40 CFR 146.7; (2) Tabulation of wells in the area of review. Tabulation of wells as described by 40 CFR 146.70(a)(3). See also 40 CFR 144.55 and 146.7; (3) Injection and confining zone description. A narrative geologic, hydrologic, and engineering report on the proposed injection and confining zone, including: (A) Isopach and structural maps of the injection and confining zone as described by 40 CFR 146.14(a)(5) & (6) and 146.70(a)(6) & (7); (B) A discussion of known or potential fluid flow directions and fluid distributions within the injection zone(s) as described by 40 CFR 146.14(a)(8) and 146.70(a)(9); and (C) Information on the confining zone as described by 40 CFR 146.70(a)(9) to include chemical properties (organic carbon content), physical properties (specifically, horizontal & vertical permeability, porosity, saturated pore volume), radiological properties (radiological logs) and any additional parameters as determined necessary by the applicant; (4) Drawings. Scale drawings of all proposed pre-treating and/or auxiliary surface equipment, including any backup, fail safe, or standby systems to be utilized in case of well failure, as described by 40 CFR 146.14(a)(11) & (12) and 146.70(a)(12) & (13); (5) Plugging and abandonment plan. Any well to be permanently abandoned shall be immediately plugged in a manner to permanently prevent the migration of any disposed substances out of the disposal zone, as well as the migration of oil, gas, or salt water into or out of any productive formations by means of the well bore. (A) Plugging shall be by a series of continuous cement plugs from the total depth of the well to ground level. (B) The top of any plugged well shall clearly show the well permit number and date of plugging by permanent marking on a steel plate welded to the surface casing. (C) The operator shall submit for DEQ approval updated plans for the proper disassembly, decontamination and restoration of the site at least one hundred-eighty (180) days prior to cessation of operations. The plans shall include the following: (i) Methods for reconditioning, recycling, or disposal of all contaminated materials, residual liquids, sludges, soils, and ancillary equipment such as pumps, piping, tubing, and tanks; (ii) Plans for restoration of the site, including provisions for proper cover to prevent excessive runoff and erosion; and (iii) Narrative description of methods for proper closure of all permitted nonhazardous impoundments. (D) The approved plugging and abandonment plan shall be implemented and completed 4

within six (6) months, unless otherwise specified by the DEQ. (E) The operator shall notify the DEQ of the exact time when plugging operations will take place. (F) Within thirty (30) days after a well has been plugged, the owner or operator shall file a plugging record with the DEQ. (6) Cost estimate. A cost estimate for plugging and abandonment, as described by 40 CFR 144.62; and (7) Financial assurance. Financial assurance for all Class I waste injection wells as required by 40 CFR 144 Subpart F. 252:652-5-2. Class III injection well facilities The plugging and abandonment plan to be included in an application for a permit for any Class III injection well facility shall be the same as required above in OAC 252:652-5-1(a)(5)(B) through (F) inclusive. 252:652-5-3. Class V injection well facilities The applicant shall perform groundwater monitoring, provide an analysis of injected fluids and a description of the geologic strata through and into which injection is taking place, and provide any additional information which the applicant determines is necessary to comply with 40 CFR 144.12. SUBCHAPTER 7. CONSTRUCTION REQUIREMENTS 252:652-7-1. Class I injection well facilities 252:652-7-2. Class III injection well facilities 252:652-7-3. Class V injection well facilities [RESERVED] 252:652-7-1. Class I injection well facilities The following shall apply to owners and operators of all Class I injection well facilities: (1) Annulus pressure and fluid. To maintain annulus pressure, a pressure tank shall be installed and equipped with the following: (A) Sensors or measuring devices to enable monitoring of the fluid level in the tank; (B) Clearly displayed design pressure and test pressure ratings; and (C) Bursting discs and/or relief valves vented to the atmosphere, as appropriate. (2) Monitoring taps. Injection and annulus pressure monitoring taps shall be provided for the use of the DEQ. The taps shall be connected near the locations on the well of the facility pressure monitor recorders. The taps shall be a one fourth (1/4) inch diameter National Pipe Thread female pipe fitting, valved and capped to prevent fluid loss when not in use. The taps shall be located to allow simultaneous pressure monitoring by facility pressure recorders and DEQ pressure gauges. (3) Surface casing. The surface casing shall extend from the surface down to fifty feet or more below the lowest underground source of drinking water. (4) Ambient monitoring. At least one monitoring well shall be installed and maintained by the owner. The DEQ may require additional wells to adequately monitor groundwater quality and level around the site. Specifications for the location, construction and maintenance of monitoring and/or observation wells must be approved by the DEQ prior to installation. (A) Well(s) shall monitor the lowest underground source of drinking water beneath the site. (B) Well(s) shall be located so that one or more wells are placed hydraulically down gradient from the site. 5

252:652-7-2. Class III injection well facilities The surface casing of all Class III injection well facilities shall extend from the surface down to fifty feet or more below the lowest underground source of drinking water. 252:652-7-3. Class V injection well facilities [RESERVED] SUBCHAPTER 9. ADDITIONAL OPERATING REQUIREMENTS 252:652-9-1. Class I injection well facilities 252:652-9-2. Class III injection well facilities [REVOKED] 252:652-9-3. Class V injection well facilities [REVOKED] 252:652-9-1. Class I injection well facilities The following shall apply to owners and operators of all Class I injection well facilities: (1) Maximum injection pressure. The permitted maximum injection pressure that can be applied at the well head may be adjusted to account for pressure loss due to friction in piping or tubing. (A) Overburden pressure gradient established. The maximum total pressure gradient (applied injection pressure plus fluid pressure) shall not exceed sixty-five percent (65%) of the established overburden pressure gradient, expressed in pounds per square inch per foot (psi/ft) of depth from ground surface to the top of the disposal zone. (B) Overburden pressure gradient not established. If the effective overburden pressure gradient is not established, the maximum total pressure gradient shall not exceed 0.65 psi/ft of depth from ground surface to the top of the disposal zone. (2) Annulus pressure. (A) For nonhazardous facilities, the annulus fluid shall be maintained at a minimum positive pressure of 10 pounds per square inch gauge at the well head. (B) For hazardous facilities, the annulus fluid shall be maintained at a pressure in accordance with 40 CFR 146.67(c). (3) Groundwater tests. Groundwater from monitoring wells shall be analyzed for parameters specified in the permit at least once each month. The analyses and water levels shall be submitted as part of the quarterly report. (4) Semi-annual pressure test. To satisfy 40 CFR 146.8(b)(2), the operator shall shut the well in semi-annually and pressurize the annulus for two (2) hours. Test pressure shall be at a minimum of 300 pounds per square inch or 125 % of the highest operating annulus pressure, whichever is greater, unless otherwise specified by the DEQ. Pressure loss or gain exceeding - 5 % or + 10 % respectively, from initial test pressure, will require additional tests and/or immediate repairs to ensure the mechanical integrity of the well. (5) Solids or sludges tests. Any solid materials or sludges produced by or resulting from pre-treatment, filtering, or storage of fluids to be injected shall be tested to determine if they are hazardous wastes. Records of the disposition of the solids/sludges shall be kept on-site. 252:652-9-2. Class III injection well facilities [REVOKED] 252:652-9-3. Class V injection well facilities [REVOKED] SUBCHAPTER 11. CLASS V DRINKING WATER TREATMENT RESIDUAL WELLS 6

252:652-11-1. Definitions 252:652-11-2. Dual Permit 252:652-11-3. Class V DWTR Permit 252:652-11-1. Definitions The following words and terms, when used in this Subchapter, shall have the following meaning, unless the context clearly indicates otherwise. "Drinking Water Treatment Residual" (DWTR) shall mean wastewater (e.g. membrane filter reject water) from drinking water treatment processes. "Dual Permit" shall mean a Class V permit for the injection of DWTR into a Commercial Class II-D well permitted by the Oklahoma Corporation Commission (OCC). 252:652-11-2. Dual Permit (a) Applicability. An existing Commercial Class II-D injection well, authorized under the rules of OCC can be additionally permitted as a Class V injection well through DEQ for the injection of DWTR. (b) Application. An application for a dual permit under this shall be submitted to DEQ for approval. (c) Permit term. The permit term for an injection well permitted under this shall not exceed a period of ten (10) years. 252:652-11-3. Class V DWTR Permit (a) Applicability. Class V permits for the injection of DWTR, which are not regulated under 2 of this Subchapter, shall be regulated in accordance with this. (b) Application. An application for a permit, under this, shall be submitted to DEQ for approval. (c) Construction and Operation. The construction and operation requirements of a Class V DWTR injection well shall be in accordance with the Commercial Class II-D injection well requirements in OAC Title 165. (d) Permit term. The permit term for a well permitted under this shall not exceed a period of ten (10) years. (e) Financial assurance. Financial assurance is required for all Class V DWTR injection wells, permitted under this, in accordance with 40 CFR 144 Subpart F. 7