Sensors & Transducers Published by IFSA Publishing, S. L., 2017

Similar documents
Through-Plane & In-Plane Conductivity of Polymer Electrolyte Membranes

GA A23414 GENERAL ATOMICS/SAN DIEGO STATE UNIVERSITY TEAM INVESTIGATES IFE TARGET HEATING DURING INJECTION

Data Report on Corrosion Testing of Stainless Steel SNF Storage Canisters

Oxidation behavior of Fe- and Ni-base alloys in supercritical CO2 and related environments

Advances in Low Temperature Coatings for Solid Oxide Fuel Cell Components

Comparison of Grade 91 and 347H Corrosion Resistance of Low- Temperature Components in Direct Supercritical CO₂ Power Cycles

Task 6.3/ Silicon Carbide Joining

A0606. Functional SOFC Interfaces Created by Aerosol-Spray Deposition

Inventors: Paul L. Micheli Mark C. Williams Edward L. Parsons

DIRECT ENERGY CONVERSION FISSION REACTOR

Steven Melzer, Melzer Consulting. Presented at the 19 th Annual CO 2 Flooding Conference. December 11-13, 2013, Midland, Texas

Operation of DIII-D National Fusion Facility and Related Research Cooperative Agreement DE-FC02-04ER54698 (GA Project 30200)

SiC/SiC Composite Properties and Flow Channel Insert Design

CO 2 SELECTIVE CERAMIC MEMBRANE FOR WATER-GAS-SHIFT REACTION WITH CONCOMITANT RECOVERY OF CO 2

RATE OF NO X EVOLUTION FROM SODIUM NITRITE/BORIC ACID SOLUTIONS (U)

NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report November 15,1996 to January 14,1997

IGR NOx/SOx Control Technology

GASOLINE FROM NATURAL GAS BY SULFUR PROCESSING

ENHANCED COAL BED METHANE PRODUCTION AND SEQUESTRATION OF CO 2 IN UNMINEABLE COAL SEAMS

Y-I 2 MASTER DEC OAK RIDGE %I 2 PLANT YIAMT-269 WECEIV&===J. CRADA Final for CRADA Number Y

DISSOLVED OXYGEN REDUCTION IN THE DIII D NEUTRAL BEAM ION SOURCE COOLING SYSTEM

Robust flue gas probes for industrial emissions measurements.

VALUE-ADDED PRODUCTS FROM REMOTE NATURAL GAS

Task Enhanced Mobility of Dense Nonaqueous-Phase Liquids (DNAPLs) Using Dissolved Humic Acids

Stability of Optical Elements in the NIF Target Area Building

Report On Adsorption/Desorption Studies of CO on PEM Electrodes Using Cyclic Voltammetry. Sethuraman, Vijay Anand

CORROSION IN ACID GAS INJECTION SYSTEMS - PROJECT 101

Diffusion Coatings for Corrosion Resistant Components in Coal Gasification Systems

Air Cooled Condenser Users Group: Corrosion Product Transport Monitoring

Advanced Ultra Supercritical (A-USC) Technology Developments and Update on the US DOE-funded A-USC ComTest Project

OPTIMIZATION OF MICROWAVE HEATING IN AN EXISTING CUBICLE CAVITY BY INCORPORATING ADDITIONAL WAVE GUIDE AND CONTROL COMPONENTS

Optimization of porous current collectors for PEM water electrolysers

SYNGAS-FIRED ALLAM CYCLE PROJECT UPDATE

R. B. Dinwiddie, G. E. Nelson, and C. E. Weaver

Alkaline Detergent Recycling Via Ultrafiltration

Material Tested To-Date

STP-PT-050 AN INVESTIGATION OF THREE RADIOGRAPHIC ACCESS PORT PLUG GEOMETRIES AND THE SURROUNDING PIPE WALL UNDERGOING CREEP

Selection and Installation of a Full- Flow Condensate Filtration System

HFIR COLD NEUTRON SOURCE MODERATOR VESSEL DESIGN ANALYSIS. S. J. Chang. Research Reactors Division Oak Ridge National Laboratory Oak Ridge, Tennessee

FABRICATION OF A NEW TYPE OF DOUBLE- SHELL TARGET HAVING A PVA INNER LAYER

Lessons Learned from Continuous Commissioning of a LEED Gold Building in Texas

Ceramic Membranes for Oxygen Production in Vision 21 Gasification Systems

Effect of Reactor Design on the Plasma Treatment of NOx

Evaluation of the Impact of Off-Design Operation on an Air-Cooled Binary Power Plant. G. L. Mines. September 22, 2002 September 25, 2002

COMPARISON OF OXIDATION POWER SENSOR WITH COUPLED MULTIELECTRODE ARRAY SENSOR FOR MONITORING GENERAL CORROSION

Improvement of Fracturing for Gas Shales

Questions to be Addressed in the Next Yucca Mountain Performance Assessment Analy sisa. R. W. Barnard and G. E. Barr Sandia National Laboratories

ITM Oxygen Development for Advanced Oxygen Supply

Mock- Up Scrubber System

Chapter 7a- Interpreting Polarization Curves

4lliedSig nal - AEROSPACE. An Integrated, Subsurface Characterization System for Real-Time, In-Situ Field Analysis

Carbon Steel and Magnesium Oxide Dissolution for H-Canyon Process Applications

Inventor: Christopher P. Boring CERMET CRUCIBLE FOR METALLURGICAL PROCESSING. DOE Docket S-7 9,301 DISCLAIMER

SUPERCRITCAL-FLUID CARBON DIOXIDE (SCCOz) CLEANING OF NUCLEAR WEAPON COMPONENTS

PROPERTIES FOR COMPOSITE MATERIALS IN HYDROGEN SERVICE

NEUTRON. Prepared. Neil W. Dotzenrod John A. Hamling. Edward N. Steadman John A. Harju. University. Grand Forks,

Compact flue gas analyser: testo 300 M-I

MOISTURE AND AGING EFFECTS ON SOLDER WETTABILITY OF COPPER SURFACES

DOE Project Officer: DOE GRANT NO.: ParaMagnetic Logging, Inc. SUMMARY ANNUAL REPORT. Principal Investigator:

Metal-Matrix Composites and Thermal Spray Coatings for Earth Moving Machines Quarter 5 Report

Bragg diffraction using a 100ps 17.5 kev x-ray backlighter and the Bragg Diffraction Imager

OXYGEN ENHANCED COMBUSTION FOR NOx CONTROL

3ii. io.e/pc/ COMMERCIAL DEMONSTRATION OF THE NOXSO SOJNO, REMOVAL FLUE GAS CLEANUP SYSTEM 7 U Quarterly Technical Progress Report No.

ICC-ES Evaluation Report Reissued December 1, 2011 This report is subject to renewal in two years.

STRUCTURAL RESPONSE OF THE DIII D TOROIDAL FIELD COIL TO INCREASED LATERAL LOADS

Supporting information

max g/l (approx. 1.9 lb/gal) (aluminum) 31.2 m²/l for 25 µm (1251 ft²/us gal for 1.0 mils)

Argonne National Laboratory, Argonne, IL

Reference Electrode for Monitoring Cathodic Protection Potential

Latest Developments to Examine the Use of CO 2 and Ethane for EOR in the Bakken and Williston Basin Conventional Reservoirs

Data File. May Contacts Details:

Data File. May Contacts Details:

BELL CREEK TEST SITE BASELINE MVA INITIATED

Electrostatic Precipitation System for

Experimental Studies to Determine Effects of Vapor Corrosion Inhibitors for Mitigating Corrosion in Casing. T5J 3N7 Canada ABSTRACT

Ion Transport Membrane (ITM) Technology for Lower-Cost Oxygen Production

GRAPHITE TILE THERMAL PERFORMANCE ON NEW DIII-D LOWER DIVERTOR

Integration of Ion Transport Membrane Technology with Oxy-Combustion Power Generation Systems

Strain Limit Criteria to Predict Failure C0A^-^7l i $- ~. t%

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: ISOLATEK INTERNATIONAL

DEVELOPMENT OF ELECTROLESS PROCESS FOR DEPOSITION OF ZN SILICATE COATINGS

GA A25655 DETERMINISTIC FABRICATION AND CHARACTERIZATION OF FILL TUBE SURROGATE TARGETS FOR OMEGA EXPERIMENTS USING A POLYMER STALK

Comparison of Grade 91 and 347H Corrosion Resistance in the Low-Temperature Components of Direct Supercritical CO2 Power Cycles

CO 2 Capture from Steam Methane Reformers: Commercial Scale Demonstration Project

Femtosecond Laser Materials Processing. B. C. Stuart P. S. Banks M. D. Perry

THERMAL RESPONSE OF SUBSTRATE STRUC_RAL MATERIALS DURING A PLASMA DISRUPTION w. Ahmed Hassanein and Dale L. Smith

J. F. Koenig THERMAL STABILITY OF GADOLINIUM NITRATE SOLUTION AT HIGH TEMPERATURE

TECHNICAL REPORT September 1 through November 30,1994. DOE Cooperative Agreement Number: DE-FC22-92PC92521(Year 3) ICCI Project Number:

Improvement of corrosion resistance of HVOF thermal sprayed coatings by gas shroud

Fjfi:wmq371 FD:3-3Ew p)fmn-s- us=-&4905d371

DAMPNESS MEASUREMENT IN CONCRETE FLOORS.

VISUALIZATION STUDY OF CATHODE FLOODING WITH DIFFERENT OPERATING CONDITIONS IN A PEM UNIT FUEL CELL

CORROSION ENVIRONMENT PROBE INTERNAL CHECK F E B B C = MEASURE C D = REFERENCE D E = CHECK AC DRIVE CARBON STEEL DUCTILE IRON

Proton-Conducting Dense Ceramic Membranes for Hydrogen Separation. Technical Progress Report. (Annual) 09/01/01 08/30/02

GA A27249 EXPERIMENTAL TESTS OF STIFFNESS IN THE ELECTRON AND ION ENERGY TRANSPORT IN THE DIII-D TOKAMAK

ONLINE MONITORING OF CORROSION UNDER CATHODIC PROTECTION CONDITIONS UTILIZING COUPLED MULTIELECTRODE SENSORS

WM2013 Conference, February 24-28, 2013, Phoenix, Arizona, USA

Temperature profiles of an air-cooled PEM fuel cell stack under active and passive cooling operation

Compact Gasification Integration Studies

National Accelerator Laboratory

Transcription:

Sensors & Transducers Published by IFSA Publishing, S. L., 2017 http://www.sensorsportal.com Membrane-Coated Electrochemical Sensor for Corrosion Monitoring in Natural Gas Pipelines 1 J. Beck, 1 D. M. Hall, 2 M. Ziomek-Moroz and 1, 3, 4 S. N. Lvov 1 Earth Mineral Sciences Energy Institute, The Pennsylvania State University, University Park, PA 16802, USA 2 National Energy Technology Laboratory, U.S. Department of Energy, Albany, OR 97321, USA 3 Department of Energy and Mineral Engineering, Pennsylvania State University, University Park, PA 16802, USA 4 Department of Materials Science and Engineering, Pennsylvania State University, University Park, PA 16802, USA E-mail: Margaret.Ziomek-Moroz@netl.doe.gov, lvov@psu.edu Received: 1 June 2017 /Accepted: 12 July 2017 /Published: 31 July 2017 Abstract: Electrochemical sensors can be used for a wide range of online in-situ process monitoring applications. However, the lack of a consistent electrolyte layer has previously limited electrochemical monitoring in gas and supercritical fluid streams. A solid state sensor is being designed that uses an ion conducting membrane to perform conductivity and corrosion measurements in natural gas pipelines up to 1000 psi. Initial results show that membrane conductivity measurements can be correlated directly to water content down to dew points of 1 C with good linearity. Corrosion monitoring can also be performed using methods such as linear polarization resistance and electrochemical impedance spectroscopy (EIS), though care must be taken in the electrode design to minimize deviation between sensors. Keywords: Sensor, Corrosion, Conductivity, Electrochemical impedance spectroscopy, Natural gas, Highpressure, Moisture, Carbon dioxide. 1. Introduction Electrochemical sensors are regularly used for the detection of chemical species in many industrial operations. The most common example is potentiometric measurement of ph. In addition to ph, dissolved oxygen sensors (e.g. the Clark electrode) and corrosion sensors are good examples of electrochemical sensors used in industrial operations. Systems using bulk aqueous streams provide a suitable electrolyte for most electrochemical measurements. However, operation is currently limited in environments where water is distributed within a compressed gas or supercritical fluid. In such environments, the dispersed water does not provide adequate ion conductivity for conventional electrochemical sensors. Furthermore, many sensor designs are not suitable for high-pressure operation. The development of solid state electrochemical sensors for non-aqueous environments will allow for improved monitoring of such streams for impurities and corrosion. In our earlier studies the National Energy Technology Laboratory and the Pennsylvania State University prepared an initial design as part of their collaborative project for performing corrosion 28 http://www.sensorsportal.com/html/digest/p_2936.htm

measurements in water-contaminated supercritical CO 2 pipelines [1-2]. These probes utilized a thin film of ion conducting polymer deposited across three electrodes, where moisture from the bulk CO 2 phase allowed the polymer film to serve as the electrolyte. The study found that electrochemical corrosion measurements could be accomplished, although the quality of the deposited polymer film and its contact with the electrodes affected the measurements. The current project has improved upon this design and focused on its application to natural gas transmission pipelines. Commercial Nafion membranes are used as the electrolyte to reduce the variability and contact issues with the polymer film. Electrode geometries have been adapted from test cells used for determining conductivity of polymer electrolyte membrane (PEM) fuel cells to provide reliable and repeatable contact. An example is shown in Fig. 1. In this way, a five-electrode cell can be used to provide both corrosion measurements and accurate conductivity measurements of the membrane. As the conductivity of the membrane depends on the concentration of water in the gas stream, the results can be used to determine the water content of the stream. This is the determining factor for the corrosion risk of a natural gas pipeline, as corrosion generally does not occur without condensed water. While the conductivity of commercial membranes has been studied extensively for PEM fuel cells, almost all data are at ambient pressure. High-pressure conductivity measurements may be required to calibrate the sensor for more aggressive environments. temperature, which is the temperature at which water will condense in a gas of known pressure. The dew point is directly related to the saturation pressure, which is the pressure at which water will condense in a gas of known temperature. Finally, relative humidity is the ratio of the current water content to the saturated content at the gas temperature and pressure. This is often calculated using the partial pressure and saturation pressure of water. As an example, Fig. 2 shows the water content, in lb/mmscf, at 1000 psi as a function of dew point temperature calculated from ASTM D1142. It can be seen that the maximum water content, and thus the saturation pressure, increases considerably with the gas temperature. Fig. 2. Water content in 1000 psi (6.9 MPa) natural gas as a function of dew point temperature [3]. In Fig. 3 we see that while water saturation increases with temperature, relative humidity decreases with temperature when the dew point is held constant. Fig. 1. Four-electrode conductivity probe for high-pressure gas systems [3-4]. 2. Water in Natural Gas Pipelines Corrosion risk in natural gas pipelines is tied to the risk of condensation in the line. Saturation of water is a function of both the temperature and pressure of the gas, the latter of which can be as high as 1000 psi (6.9 MPa) in tranmission lines. Water solubility in natural gas can be calculated according to ASTM D1142 [5]. There are many ways the water content can be reported. In the natural gas industry it is often reported in terms of pounds-water per million standard cubic feet of gas (lb/mmscf), where the gas is assumed to be 60 F (15.6 C) and 14.7 psi (0.1 MPa). Absolute water content can also be reported in mole/mass/volume fraction and partial pressure of water in the gas stream. Another common measure is the dew point Fig. 3. Relative humidity in 1000 psi (6.9 MPa) natural gas as a function of gas and dew point (DP) temperature [5]. Calculations have found that, for constant gas and dew point temperature, relative humidity is largely independent of the total gas pressure. However, the total water content at saturation decreases almost linearly with total pressure. For example, at a constant dew point and gas temperature, increasing the gas pressure from 100 to 1000 psi would decrease the saturated water content by a factor of 10. 29

3. New Sensor Design Nafion 117 was selected as the membrane material due to its commercial availability and the considerable body of literature available on its properties. The sensor design is taking place in two stages. The first is the assembly of the high-pressure four-electrode conductivity probe. In a four-electrode cell, the outer two electrodes, shown as platinum wires in Fig. 1, pass a current between them. The inner two electrodes measure the electric potential change across the membrane caused by the ohmic drop. While a twoelectrode cell allows a more simple design, the use of four electrodes increases measurement accuracy as errors due to electrochemical reactions on the electrodes are mitigated. The second stage is the addition of a fifth carbon steel electrode between the inner two platinum electrodes. Combining the steel electrode with two of the conductivity electrodes allows a three-electrode cell for making corrosion measurements. The Nafion membrane will provide a consistent electrolyte for electrochemical measurements, such as linear polarization resistance and EIS, to monitor corrosion behavior over time. The assembly could eventually allow the inclusion of further electrodes for additional real-time electrochemical measurements of gas-phase and corrosion properties. The electrodes are set into a polytetrafluoroethylene (PTFE) base, which is chemically stable over a wide range of temperature and chemical environments. A PTFE or perforated stainless steel disk is screwed against the base to ensure adequate contact between the electrodes and the membrane, with a porous insulator used to prevent electrical contact between the electrodes and the steel disk. The sensor is then housed in a stainless steel assembly, as shown in Fig. 4, that is made up of commercial off-the-shelf parts to reduce costs and simplify installation. 4. Conductivity Results Initial conductivity measurements were performed using a commercial membrane conductivity system designed for PEM fuel cell development. Fig. 5 presents the low pressure commercial system used. Fig. 5. Low pressure conductivity test cell. The system was chosen to provide a comparison point for later tests using the high-pressure probe. Measurements were made using EIS in 100 psi nitrogen for gas temperatures between 86 and 167 F (30 and 75 C) and dew points between 34 and 64 F (1 and 18 C). The results are given in Fig. 6, where the dew point was translated into water content at 100 psi (0.69 MPa). Fig. 6. Conductivity of Nafion 117 with water content in 100 psi (0.69 MPa) nitrogen using the commercial conductivity system [4]. Fig. 4. Assembled high-pressure conductivity sensor. The design and materials of construction are compatible in a wide range of environments with temperatures and pressures above 300 F (149 C) and 1000 psi (6.9 MPa), meaning that it should be applicable to many processes beyond natural gas transmission. Conductivity of the membrane increased linearly with water content. The decrease in conductivity with gas temperature follows the trend of decreasing relative humidity shown previously in Fig. 3. Measurements were repeated in 100 psi (0.69 MPa) methane and a 90/10 % mixture of methane/carbon dioxide. The conductivity of the membrane was found to be largely independent of the gas composition, even 30

with the presence of an acid gas such as carbon dioxide. Two high-pressure conductivity probes were assembled and tested simultaneously in 100 psi (0.69 MPa) nitrogen at 140 F (60 C) for comparison with the commercial cell. The results are shown in Fig. 7. There was generally good agreement between the measuremets using the homemade and commercial cells. The decrease in linearity was attributed to instability in the dew point control, as the trend was observed in both probes. time water was found to collect in the dead legs which affected humidity control of the system. The new test cell was pressure tested up to 1000 psi and 75 C. The high-pressure conductivity sensors attached to the system using 1 in. compression tubing fittings. A thermocouple and pressure transducer were connected opposite one of the sensors to monitor the temperature and pressure of the test cell. The conductivity results are shown in Fig. 9. The membrane conductivity was largely unchanged with the increase in total pressure, following the correlation with relative humidity discussed in Section 2. The offset between the probes is attributed to small variations in the electrode spacing between the two assemblies. These results show that calibration and confirmation of conductivity probe data can be completed below the operating pressure to decrease both cost and calibration time without major effects on the accuracy. One issue of note is that the response time decreased considerably in the high-pressure environment. Use of a thinner membrane is being investigated to improve the response. Fig. 7. Conductivity of Nafion 117 with water content in 100 psi (0.69 MPa) nitrogen using the homemade (Probs 1 and 2) and commercial probes. The high-pressure probes were then tested in 1000 psi (6.9 MPa) nitrogen at 140 F (60 C). The flow-through system used with the commercial cell was modified to allow high-pressure operation. A gas booster was added that compressed the test gas from 100 psi to the test pressure of 1000 psi. The use of the booster allowed more efficient use of the test gas cylinders. The commercial conductivity cell was replaced with a custom high-pressure test cell, which consisted of a 1 in. diameter stainless steel cross and tee. A picture of the cell is shown in Fig. 8. Fig. 8. High-pressure flow-through test cell with attached conductivity/corrosion sensors (right side of cell) and thermocouple/pressure transducer (left side of cell). Flow was from top to bottom through the cell to allow any trapped water to be flushed through the system. Early tests had the flow horizontal, and over Fig. 9. Conductivity of Nafion 117 with water content in 1000 psi (6.9 MPa) nitrogen using the high-pressure conductivity probes [4]. 5. Corrosion Results Proof-of-concept corrosion measurements were performed using a carbon steel electrode in the commercial conductivity cell at 100 psi (0.69 MPa) nitrogen for 140 F (60 C) with a dew point of 52 F (11 C). The measured corrosion rate ranged between 4 10-4 and 8 10-3 mpy (10-5 and 2 10-4 mm y -1 ). Linear polarization resistance (LPR) measurements were used to evaluate the corrosion rate of carbon steel. The system was held at a steady state for three days. Fig. 10 presents the corrsion rate over a 5 hour period for day 3 of the exposure test. It was found that small variations in the contact surface between assemblies caused significant variation in the measured corrosion rate. This issue was addressed by using amn X-65 carbon steel plate in place of a wire when constructing the high-pressure corrosion probes. Furthermore, the low response time was reduced by replacing the 0.0178 cm thick Nafion membrane with the 0.0022 cm thick Nafion HP membrane. 31

Fig. 10. Corrosion rate of a carbon steel wire overtime via LPR on day 3 at 60 C using the modified commercial cell. Using the Nafion HP probe, the corrosion rate was quantified for a number of different water contents governed by dew point at 100 and 1000 psi. All tests were perfromed at 60 C with N 2 as the background gas. Fig. 11 presents the LPR corrosion rate values obtained. carbon steel in 100 psi (0.69 MPa) (nitrogen using a modified commercial conductivity system found corrosion rates on the order of 10-4 to 10-3 mpy (10-5 to 10-3 mm y -1 ). The high-pressure sensor solved the contact issue by using a rigid plate for the corrosion electrode and a perforated steel face plate to ensure good contact with the membrane. Corrosion rates for X-65 carbon steel measured with the high-pressure sensor increased from 0.01 to 0.1 μm y -1 in N 2 at 60 C as the dew point increased from 1 to 18 C (7 to 21 lb/mmscf at 1000 psi). The corrosion rate was largely independent of system pressure. Initial results show promise that the current design can allow for low-cost solid state electrochemical sensors that can provide in-situ and real-time measurements of the water content and corrosivity in a natural gas pipeline. A second generation of the sensor could further improve reliability and decrease costs by depositing the electrodes and membrane onto a ceramic wafer. Once the platform for electrochemical measurements is established, it may be possible to incorporate additional electrodes, such as reference electrodes and ion selective electrodes, to increase the capabilities of the sensor. Such a sensor could be employed in a variety of gas and supercritical environments where the moisture content allows adequate conductivity of the membrane. Disclaimer Fig. 11. Corrosion rate data for acell temperautre of 60 C as a function of the dew point for the inlet humidifier. As can be seen from Fig. 11, The corrosion rate did not depend strongly on the cell pressure. Little difference was found between results obtained for 100 and 1000 psi. Additionally, the humidifier dew point weakly influenced the corrosion rate at low dew points. However at higher dew points, the corrosion rate appeared to increase significantly with increases in dew point. 6. Summary and Ongoing Work A solid state high-pressure conductivity sensor utilizing an ion conducting membrane has been designed and tested for use in natural gas transmission pipelines. Testing has found good agreement with results from a commercial membrane conductivity system in 100 psi (0.69 MPa) nitrogen from 86 to 167 F (23 to 75 C) and a linear relation between water contents and conductivity. Membrane conductivity was largely independent of gas composition and system pressure up to 1000 psi (6.9 MPa). Preliminary corrosion measurements of This article was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. References [1]. J. Beck, M. Fedkin, S. Lvov, M. Ziomek-Moroz, G. Holcomb, J. Tylczak, D. Alman, In situ electrochemical corrosion measurements of carbon steel in supercritical CO2 using a membrane-coated electrochemical probe, ECS Transactions (ECST), Vol. 45, Issue 19, 2013, pp. 39-50. [2]. M. Ziomek-Moroz, J. Beck, M. Fedkin, S. Lvov, Membrane-coated electrochemical probe for corrosion measurements of high strength carbon steel in 32

supercritical CO2, in Proceedings of the NACE International's 68 th Annual Conference CORROSION 13, 2013. [3]. J. Beck, M. Ziomek-Moroz, S. Lvov, Electrochemical Sensors for Gas Pipelines Using Ion Conducting Membranes, in Proceedings of the TechConnect World Innov. Conf. Expo on Materials for Energy, Efficiency and Sustainability, 2017. [4]. J. Beck, D. M. Hall, M. Ziomek-Moroz, S. N. Lvov, Membrane-Based Electrochemical Sensor for Corrosion Monitoring in Natural Gas Pipelines, ECS Transactions (ECST), Vol. 77, 2017. [5]. ASTM International, Standard Test Method for Water Vapor Content of Gaseous Fuels by Measurement of Dew-Point Temperature, ASTM D1142-95, 2012. [6]. BekkTech LLC, In Plane Conductivity Testing, in Proceedings of the High Temperature Membrane Working Group ACS Meeting, San Francisco, 2006. Published by International Frequency Sensor Association (IFSA) Publishing, S. L., 2017 (http://www.sensorsportal.com). 33