Theory Composite Beam Design

Similar documents
Manual Composite Beam Design

Manual Composite Beam Design

COMPOSITE STRUCTURES PREPARED BY : SHAMILAH

Design of Composite Bridges Use of BS 5400: Part 5: 1979

Universal Beam and Universal Column sections subject to pure bending are all Class 3 semi-compact or better.

Advanced Eurocode Training. EN : Composite Structures

Eurocode Training EN : Composite Structures

Structural Performance of Long-Span Composite Truss and Beam Systems in Fire

Chapter 21 Composite beams

Analysis and Design of Steel

Austral Deck Design for Construction Loading. Permanent formwork and Span capability

BS EN :2004 EN :2004 (E)

Contents. Tables. Notation xii Latin upper case letters Latin lower case letters Greek upper case letters Greek lower case letters. Foreword.

COMPOSITE BRIDGES WITH PRECAST CONCRETE SLABS

Tekla Structural Designer 2016

1. BS 5950: Structural use of steelwork in building Part 1: Code of practice for design of simple and continuous construction, BSI, 1990

Fire Safety Day Fire Behaviour of Steel and Composite Floor Systems Simple design method

Design Guidance for TAB-Deck Composite Slabs using SMD Metal Decking reinforced with ArcelorMittal Steel Fibres

Design of Steel-Concrete Composite Bridges

MasterSeries Composite SlimFloor Beam Design Sample Output

7. SPECIFIC RULES FOR STEEL CONCRETE COMPOSITE BUILDINGS

Contents. Foreword 1 Introduction 1

Table of contents. EC3 Steel Design - Class 4 calculation of effective characteristics... 5

DIN EN : (E)

CHAPTER 2. Design Formulae for Bending

Portal frame PLASTIC DESIGN OF PORTAL FRAMES

Multideck 146. Contents

3.4.2 DESIGN CONSIDERATIONS

Comparative Study of R.C.C and Steel Concrete Composite Structures

Steel-concrete Composite Bridges Designing with Eurocodes

PERFORMANCE OF AN INNOVATIVE PRE-CAST COLD-FORMED STEEL AS COMPOSITE BEAM WITH SINGLE AND DOUBLE C- CHANNELS

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL COLLEGE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2018/2019

Design of Short Span Steel Bridges

CIVL473 Fundamentals of Steel Design

Manual Composite column design

ST7008 PRESTRESSED CONCRETE

OXFORD ENGINEERING COLLEGE (NAAC Accredited with B Grade) Department of Civil Engineering LIST OF QUESTIONS

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

DURABILITY AND SERVICEABILITY

CLT Structural Design Sylvain Gagnon, Eng. February 8, 2011 Vancouver

Flexure and Serviceability Limit State

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

STEEL DESIGNERS MANUAL

Technical Manual. The difference is.

CADS A3D MAX. How to model shear walls

Encased Beam with Variable Upper Steel Flange Position

Deflection of a Composite Beam

ANALYTICAL STUDY OF PUNCHING SHEAR ON WAFFLE SLAB WITH DIFFERENT RIB SIZES

CD 360 Use of Compressive Membrane Action in Bridge Decks

Release Note DESIGN OF CIVIL STRUCTURES. Release Date : SEP. 1, 2015 Product Ver. : Civil 2016 (v1.1)

Steel Design Guide Series. Steel and Composite Beams with. Web Openings

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

Transactions on the Built Environment vol 13, 1995 WIT Press, ISSN

Strength of Non-Prismatic Composite Self-Compacting Concrete Steel Girders

Structural Steel Products UK & Ireland. Multideck Technical Handbook

`Limit State of Collapse in Compression Design of an Axially Loaded Short Column

Practical Methods for the Analysis of Differential Strain Effects

THE STRUCTURAL BEHAVIOUR OF COMPOSITE CONNECTIONS WITH STEEL BEAMS AND PRECAST HOLLOW CORE SLABS

SHEAR DEFORMATION IMPACT ON DEFLECTION OF COMPOSITE BRIDGE GIRDERS 1 INTRODUCTION

British Steel Fire Test3: Reference ABAQUS model using grillage representation for slab. Research Report

REINFORCED CONCRETE DESIGN

BEHAVIOUR OF REINFORCED CONCRETE STRUCTURES IN FIRE

APPENDIX B ABC STRUCTURES DESIGN GUIDE

Diploma in Civil Engineering. Term-End Examination June, BCE-041 : THEORY OF STRUCTURES II

CHAPTER FIVE 5.1 MODELING OF A TEN-STOREY BUILDING

Serviceability considerations

EUROCODE 6 Design of masonry structures

midas Gen MIDAS On-Demand Service midas Gen Advanced Webinar Steel Structure Design

7 LOCAL BUCKLING OF STEEL CLASS 4 SECTION BEAMS

(a) Pin-Pin P cr = (b) Fixed-Fixed P cr = (d) Fixed-Pin P cr =

ComFlor manual Composite floor decking design and technical information

Recommendations for additional fire protection of structural elements

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Design of Beam-Columns

Development of a Modular Press-Brake-Formed Steel Tub Girder for Short-Span Bridge Applications

This is a repository copy of Recent research and development in semi-rigid composite joints with precast hollowcore slabs.

FIRE RESISTANCE OF CONCRETE SLABS ACTING IN COMPRESSIVE MEMBRANE ACTION

Lysaght Bondek. Structural steel decking system Design and Construction Manual

DESIGN OF RC ELEMENTS UNIT 1 PART-A

Metal Decking Specialists

Copyrighted material. Licensed to on 22/05/2014

US Composites User Guide and Theoretical Background

Long-term Stress of Simply Supported Steel-concrete Composite Beams

ANNEX 10. Special requirements recommended for structures subject to seismic actions. 1 Scope. 2 Basis of design. 2.1 Fundamental requirements

STT+ Single-span Steel Beam. FRILO Software GmbH As of 04/07/2016

ME 207 Material Science I

HOW TO DESIGN CONCRETE STRUCTURES Columns

Unit 48: Structural Behaviour and Detailing for Construction. Limit State Design

Strength Design of Reinforced Concrete Structures

DESIGN OF HIGH-RISE MODULAR OPEN BUILDINGS

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

SOUTH AFRICAN NATIONAL STANDARD

Evaluation of Ultimate Strength of Steel- Concrete Hybrid Girder Using 80-MPa High- Strength Concrete

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 9: Introduction to Computer Software

This final draft of the fib MC2010 has not been published; it is intended only for the purpose of voting by the General Assembly.

TECHNICAL MANUAL. PETRA Slab Hanger. Hollow-Core Support for Slab Openings

Level 6 Graduate Diploma in Engineering Structural analysis

MAHALAKSHMI ENGINEERING COLLEGE

Module Title: Advanced Structural Design

Transcription:

Theory Composite Beam Design

Composite Beam Design Theoretical Background

Introduction... 1 Composite beam design... 2 Design check to BS 5950-3.1...2 References...5 Fire resistance check to BS 5950-8...5 References...7 Design check as per EN 1994-1-1: 2004...7 References...10 Fire resistance check to EC4...10 References...14

Introduction This document briefly explains the theoretical background for the design check of composite beams. Design checks to BS 5950-3.1 and EN 1994-1-1: 2004 are outlined and fire resistance checks 5950:8 and EN 1994-12 are also presented. 1

Composite beam design Design check to BS 5950-3.1 Composite beam members may be checked for their strength, stability and stiffness in accordance with BS5950-3.1 Checks are done at final (composite) stages and also at the construction (non-composite) stages. Design code: BS 5950: Part 3: Section 3.1: 1990 Partial safety factors: In accordance with the code the following default values of PSF are used for the design checks, but are user editable. Partial safety factors on loads: Dead load : 1.40 Live load : 1.60 Partial safety factors for material strength: Structural steelwork : 1.0 Profiled steel sheet : 1.0 Reinforcement steel : 1.15 Shear connectors : 1.25 Concrete in shear : 1.25 Concrete in compression : 1.50 Limiting values: The user is responsible for defining limiting values for span/deflection ratio at serviceability limit state. The default values are, For permanent loads : 240 Variable (imposed) loads : 360 Total load : 200 Pre- camber: The program can allow for pre-camber. The user can set the pre-camber value as an absolute value (in mm) or as a proportion of span (eg L/200). Very small cambers are impractical and designers should consult fabricators or published guidance in case of doubt. Calculation parameters: The following parameters are input by the user: Type of concrete Proportion of long term loading Percentage of variable load included in the calculation of natural frequency based on static deflection. Percentage of increase in moment of inertia to allow for dynamic stiffness Natural frequency limit (minimum value) Load cases included in construction stage checks 2

Effective span: The effective span of a beam is defined by clause 5.1.1 of BS 5950-3 but in the absence of relevant data, the program will adopt the member length defined in the analysis model. Construction type: The beam may be propped or un-propped during construction. If the beam is propped during construction, construction stage analysis and design is not necessary. All beams may be designed assuming that at the ultimate limit state the whole of the loading acts on the composite member. If the beam is un-propped, construction stage checks are necessary. Using the properties of the steel beam alone without composite action. Slab type: The software supports the following types of slabs:1. Solid slabs cast in-situ 2. Haunched solid slabs cast-in-situ 3. Precast hollow core slabs 4. Composite in-situ concrete and profiled steel deck Effective breadth of concrete flange: The total effective breadth of concrete flange acting compositely with the steel beam is taken as the sum of the effective breadths of the portions of flange on each side of the centre line of the steel beam. The information available in clause 4.6 of BS 5950-3, can be used for effective breadth calculation and input by the user. For design checking, the effective flange widths for sagging and hogging regions are taken as user input separately, but for the purpose of analysis the effective flange width of the mid zone (sagging zone) is used throughout the span. Shear connection: The shear connection is assumed capable of transmitting the longitudinal shear between the concrete slab and the steel beam due to the factored loads, without causing crushing or other damage to concrete and without allowing excessive slip or separation between the concrete and steel. For the related calculations, section 5.4 described in BS 5950-3 is used. The program supports various types of shear connectors like stud, channel, bar hoop, and Hilti, which are available in the system data base, and the user can add available system data to the project data. In accordance with clause 5.5 of BS 5950-3.1, partial shear connection is allowed in the sagging region but in hogging zones, partial shear connection is discounted and the section is either fully composite or non composite. Spacing of shear connectors: The spacing of shear connectors should comply with clause 5.4.8 of BS 5950-3.1 and will be checked and reported as a warning if not satisfied. Transverse reinforcement: Transverse reinforcement refers to the reinforcement in the concrete flange running transverse to the span of the beam. Where profiled sheets are used they may also act as transverse reinforcement. Longitudinal reinforcement: 3

Longitudinal reinforcement refers to the reinforcement in the concrete flange running along the span of the beam and used to provide resistance to hogging moments if present. Resistance of concrete flange: The longitudinal shear resistance of the concrete flange is calculated in accordance with clause 5.6.3 of BS 5950-3.1 Contribution of profiled sheeting: Profiled steel sheeting is assumed to contribute to the transverse reinforcement provided it is continuous or stud welded to the beam flange. Clause 5.6.4 of BS 5950-3 is used for the necessary calculation. Section classification: Section classification is determined in accordance with clause 4.5 and Appendix C of BS 5950-3.1 Plastic moment capacity: The plastic moment capacity of a composite cross section is calculated as per the following: i. Concrete is assumed to be stressed to a uniform compression of 0.45fcu over the full depth of concrete on the compression side of the plastic neutral axis. ii. The structural steel member is assumed to be stressed to its design strength py either in tension or in compression. For a section with semi compact or slender web the effective section described in clause 4.5.3 is used. iii. Longitudinal reinforcement is assumed to be stressed to its design strength fy/γs where it is in tension. (i.e. under hogging moments with full shear connection). The plastic moment capacity of the composite beam depends on the degree of shear connection. The plastic moment capacity of the composite section for sagging and hogging zones are calculated in accordance with Appendix B of BS 5950-3.1. The plastic moment capacity in hogging zones is calculated assuming the concrete is cracked. The plastic moment capacity is reduced as per clause 5.3.4 of BS 5950-3.1 in presence of high shear force. Elastic moment capacity: The elastic moment capacity of a composite cross section is calculated based on the following: i. The strain distribution in the effective cross section is assumed linear ii. The stress distribution in the concrete is assumed to be linear, based on the appropriate value of the modular ratio from clause 4.1 and limited to a value of 0.50fcu. iii. The stress in the steel beam is limited to design strength py reduced as recommended in BS 5950: part 1 where the section is class 4 slender. Stability of compression flange: To prevent lateral buckling, the compression flange should be laterally restrained as recommended in BS 5950 part1. Stability checks are carried out as per the guidelines given in clause 5.3.5 of BS 5950 part 3. Lateral buckling checks are carried out for the construction stages using steel only section properties. Lateral torsional buckling checks are carried out for the hogging region both in the composite stage and in construction stage. Longitudinal shear resistance: 4

The longitudinal force and resistance are calculated in accordance with section 5.6 of BS 5950-3.1 Design checks: The composite beam should be checked at the construction and final stages and for the ultimate and serviceability limit states. Construction stage: In the construction stage composite action is not considered and the program will perform the following checks using only the steel beam properties. SLS Checks: At the serviceability limit state the maximum deflections are calculated and compared with the limiting values as input and the utilization ratios are reported. ULS checks: The ultimate section capacities are computed for moment, shear, buckling etc and are compared with the ultimate applied effects and the utilization ratios are reported. Final Stage: For the final stage design checks the composite section properties are computed in accordance with Appendix B of the code. For hogging moment regions cracked section properties are used. For the sagging zone, the contribution of concrete in compression within the effective flange width is considered to arrive at the resistance moment SLS Checks: At the serviceability limit state the maximum stresses and deflections are calculated and compared with the limiting values as input and the utilization ratios are reported. The natural frequency of vibration is computed by making use of deflection ratios. The deflection computed is modified as per section 6.1.4 in the case of beams with partial shear connection. ULS checks: The ultimate section capacities are computed for moment, shear, buckling etc and are compared with the applied effects and the utilization ratios reported. References 1. BS 5950: Structural use of steelwork in buildings: Part3:Section3.1:1990 Code of practice for design of simple and continuous composite beams 2. BS 5950: Structural use of steelwork in buildings: Part1:1:2000 Code of practice for design - rolled and welded sections Fire resistance check to BS 5950-8 The fire resistance check is performed in accordance with BS 5950-8:2003 Fire Limit state: The structural effects of fire in a building or part of a building are considered as a fire limit state. The fire limit state should be treated as an accidental limit state. In checking the strength and stability of the structure at fire limit state, the loads should be multiplied by partial safety factors γf as given in Table-5 of BS 5950-8. It is the responsibility of the user to create a ULS load combination for the fire limit state. Partial safety factors: The default PSF values for the material properties are taken as follows, 5

Steel : 1.00 Concrete : 1.10 Section factor: The rate of temperature increase of a steel member in a fire may be assumed to be proportional to its section factor, which may be defined as the ratio of, Am Sf V Where:Am : is the exposed surface area per unit length of the member V : is the volume of the member per unit length The section factor is calculated for 3-sides for profile/box protection in accordance with Table 6. Calculation model: The fire behaviour of hot finished steel members may be determined using either, 1. Limiting temperature method 2. Moment capacity method In this software the limiting temperature method is adopted, whereby if the limiting temperature, as per Table8 for the applicable load ratio, is not less than the design temperature given in 8.4.3 for the required period of fire resistance, the member is considered to have adequate fire resistance without protection. When the limiting temperature is less than the design temperature given in 8.4.3 the protection thickness necessary to provide adequate fire resistance may be derived from standard fire test data. The software has a good data base of fire protection materials commonly available in the UK market, obtained from Fire Protection for structural buildings published by Association for Specialist Fire Protection (ASFP) in conjunction with Fire Test Study Group (FTSG) & Steel Construction Institute (SCI). Load ratio: For beams designed in accordance with BS 5950-1 with three or four sides fully exposed, the load ratio R is taken as the greater of, R Mf Mc Or R m Mf Mb Where: Mf : is the applied moment at fire limit state Mb : is the buckling resistance moment Mc : is the moment capacity of the section M : is the equivalent uniform moment factor 6

Design temperature: The design temperature depends on the section configuration and dimensions. For beams Table-10 is used for obtaining the design temperature. Limiting temperature: The limiting temperature obtained from Tabe-8 corresponds to the load ratio. References 1. BS 5950-8:2003 Structural use of steel work in building Part-8: Code of practice for fire resistant design 2. Fire Protection for structural steel in building Published by, Association for Specialist Fire Protection (ASFP) in conjunction with Fire Test Study Group (FTSG) & Steel Construction Institute (SCI). Design check as per EN 1994-1-1: 2004 This module checks composite beam members by preparing calculations for their strength, stability and stiffness in accordance with EN 1994-1-1: 2004. Design code: BS EN 1994-1-1: 2004 Partial safety factors: In accordance with the code the following default values of PSF are used for the design checks, but are user editable Partial safety factors on loads: Dead load : 1.35 Live load : 1.50 Partial safety factors for material strength: Structural steel resistance : 1.0 Structural steel buckling : 1.0 Profiled steel sheet : 1.0 Reinforcement steel : 1.15 Shear connectors : 1.25 Concrete : 1.50 Limiting values: The user is responsible for defining limiting values for span/deflection ratio at serviceability limit state. The default values are, For permanent loads : 240 Variable (imposed) loads : 360 Total load : 200 Pre-camber: The program can allow for pre-camber. The user can set the pre-camber value as an absolute value (in mm) or as a proportion of span (eg L/200). Very small cambers are impractical and designers should consult fabricators or published guidance in case of doubt. 7

Calculation parameters: The following parameters are input by the user: Type of concrete Proportion of long term loading Percentage of variable load included in the calculation of natural frequency based on static deflection. Percentage of increase in moment of inertia to allow for dynamic stiffness Natural frequency limit (minimum value) Load cases included in construction stage checks Effective span: The effective span of a beam is defined by clause 5.4.1.2 of EN 1994-1-1: 2004 but in the absence of relevant data, the program will adopt the member length defined in the analysis model.. Construction type: The beam may be propped or un-propped during construction. If the beam is propped during construction, construction stage analysis and design is not necessary. All beams may be designed assuming that at the ultimate limit state the whole of the loading acts on the composite member. If the beam is un-propped, construction stage checks are performed using the properties of the steel beam alone without composite action. Slab type: The software supports the following types of slabs:1: Solid slabs cast in-situ 2: Haunched solid slabs cast-in-situ 3: Precast hollow core slabs 4: Composite in-situ concrete and profiled steel deck Effective breadth of concrete flange: The total effective breadth of concrete flange acting compositely with steel beam is taken as the sum of the effective breadths of the portion of flange on each side of the centre line of the steel beam. The information available in clause 5.4.1.2 of EN 1994-1-1: 2004, can be used for effective breadth calculation and input by the user. Shear connection: The shear connection is assumed capable of transmitting the longitudinal shear between the concrete slab and the steel beam due to the factored loads, without causing crushing or other damage to concrete and without allowing excessive slip or separation between the concrete and steel. For the related calculations section 6.6 described in EN 1994-1-1: 2004 is used. The program various types of shear connectors like stud, channel, bar hoop, and Hilti, which are available in the system data base, and the user can add the available system data to the project data. In accordance with section 6.6 of EN 1994-1-1: 2004, partial shear connection is allowed in the sagging region, but in the hogging regions partial shear connection is discounted and the section is either fully composite or non composite Spacing of shear connectors: 8

The spacing of shear connectors should comply with clause 6.6 of EN 1994-1-1: 2004 and this will be checked and reported as a warning if not satisfied. Transverse reinforcement: Transverse reinforcement refers to the reinforcement in the concrete flange running transverse to the span of the beam. Where profiled sheets are used they may also act as transverse reinforcement. Longitudinal reinforcement: Longitudinal reinforcement refers to the reinforcement in the concrete flange running along the span of the beam and used to provide resistance to hogging moments if present. Resistance of concrete flange: The longitudinal shear resistance of the concrete flange is calculated in accordance with clause 6.2.1.2 of EN 1994-1-1: 2004 Contribution of profiled sheeting: Profiled steel sheeting is assumed to contribute to the transverse reinforcement provided it is continuous or stud welded to the beam flange. Clause 6.6.6.4 of EN 1994-1-1: 2004 is used for the necessary calculation. Section classification: Section classification is determined in accordance with section 5.5.2 of EN 1994-1-1: 2004 and table 5.2 of EN 1993-1-1. Plastic moment capacity: The plastic moment capacity of a composite cross section is calculated as per the following: i. Concrete is assumed to be stressed to a uniform compression of fck/γc over the full depth of concrete on the compression side of the plastic neutral axis. ii. The structural steel member is assumed to be stressed to its design strength py either in tension or in compression. For a section with semi compact or slender web the effective section described in clause 6.2.2.4, fig 6.3 of EN 1994-1-1: 2004 is used. iii. Longitudinal reinforcement is assumed to be stressed to its design strength fy/γs where it is in tension (ie under hogging moments with full shear connection). The plastic moment capacity of the composite beam depends on the degree of the shear connections. In the absence of specific guidance in EC4, the plastic moment capacity of the composite section for the sagging zone and hogging zone are calculated in accordance with Appendix B of BS 5950-3. The plastic moment capacity in hogging regions is calculated assuming the concrete is cracked. The plastic moment capacity is reduced as per clause 6.2.2.4 of EN 1994-1-1: 2004 in presence of high shear force. Elastic moment capacity: The elastic moment capacity of composite cross section is calculated on the basis of the following: i. The strain distribution in the effective cross section is assumed linear 9

ii. The stress distribution in the concrete may be assumed to be linear, based on the appropriate value of the modular ratio from clause 4.1 and limited to a value of 0.50fck. iii. The stress in the steel beam is limited to design strength py reduced as recommended in clause 7.1 of EN 1994-1-1: 2004 where the section is class 4 slender. Stability of compression flange: To prevent lateral-torsional buckling under hogging moment in the final condition, the compression flange may require additional lateral restraint. Stability check is carried out as per the guidelines given in clause 6.4.2 of EN 1994-1-1: 2004. Lateral torsional buckling checks are carried out in the hogging regions for the final stage using composite properties as per clause 6.4.2. Longitudinal shear resistance: The longitudinal force and resistance are calculated in accordance with section 6.6.6 of EN 1994-1-1: 2004. Design checks: Composite beam should be checked at the construction and final stages and for the ultimate and serviceability limit states. Construction stage: In the construction stage the following checks has to be performed by using steel section properties. SLS Checks: At the serviceability limit state the maximum deflections are calculated and compared with the limiting values as input and the utilization ratios are reported. ULS checks: The ultimate section capacities are computed for moment, shear, buckling etc and are compared with the ultimate applied effects and the utilization ratios are reported At present the program can not perform construction stage checks for the composite beams but the user can still make use of the existing Esa steel check functionality to perform checks at construction stage. Final Stage: For final stages design checks the composite section properties are computed in accordance with Appendix B of BS 5950-3.1. For the hogging moment region the cracked section properties are used for the sagging zone the contribution of the concrete in compression within the effective flange width is considered to arrive at the resistance moment SLS Checks: At the serviceability limit state the maximum stresses and deflections are calculated and compared with the limiting values as input and the utilization ratios are reported. The natural frequency of vibration is computed by making use of deflection ratios. In the absence of EC guidance the deflection computed is modified as per section 6.1.4 of BS-5950-3 in the case of beams with partial shear connection. ULS checks: The ultimate section capacities are computed for moment, shear, buckling etc and are compared with the applied effects and the utilization ratios reported. References Eurocode 4 (BS EN 1994-1-1:2004) Design of composite steel and concrete structures Part-1-1 General rules and rules for building. Fire resistance check to EC4 The fire resistance check is performed in accordance with BS EN 1994-1-2 10

Fire actions / Effects: The effects at fire limit state should be computed as per section 2.4.2 of EC4. The reduction factor ήfi is calculated for the load combinations using combination factors Ψfi in accordance with EN 1991-1-2. The user can make use of the ULS accidental combination option available in ESA PT for creating the load combination for the fire check. Users can also create their own ULS combinations for the fire check. Partial safety factors: The default PSF values for the material properties are taken as 1.0 in accordance with EC4. Temperature-time curves: The program supports three different types of fire curves as listed below, 1. Standard temperature-time (ISO 834) curve 2. External fire curve 3. Hydro carbon curve Standard temperature-time curve The standard temperature-time curve can be defined by the following equation, g 20 345 log 8 t 1 with, coefficient of heat transfer by convection( άc) c 25 W/m 2 K External fire curve The external fire curve can be defined by the following equation, g 20 660 1 0.687 e 0.32 t 0.313 e 3.8 t with, coefficient of heat transfer by convection( άc) c 25 W/m 2 K Hydro carbon curve The hydrocarbon curve can be defined by the following equation, g 20 1080 1 0.325 e 0.167t 0.675 e 2.5 t with, coefficient of heat transfer by convection( άc) c 50 W/m 2 K Temperature of steel beam: 11

The temperature increase in the steel profile depends on whether the section is protected or not. For an unprotected section the increase in temperature ( Δθat ) during the time interval (Δt) may be determined from:- at Kshadow 1 Ca a ( Sf ) hnet t where, Kshadow : is a correction factor for shadow effect calculated as following b1 2 0.9 e1 e2 Kshadow hw b1 hw b2 2 1 ( b1 b2 )2 4 2 e1 e2 Ca : is the specific heat of steel [J/kgK] ρa : is the density of steel [kg/m3 ] Sf : is the section factor of the steel beam/ part of the beam [m-1] hnet Δt ew : is the design value of the net heat flux per unit area [W/ m2] : is the time interval, taken as 5 sec. For a protected section the increase in temperature (Δθat ) during the time interval (Δt) may be determined from, p at w dp Api Vi ( Ca a ) 1 1 w ( t at ) t e 10 1 at 3 Where:- w Cp p Api dp Vi Ca a λp : is the thermal conductivity of the fire protection material [W/mK] ρa : is the density of steel[kg/m3 ] ρp : is the density of the fire protection material [kg/m3 ] dp : is the thickness of fire protection material [m] Api Vi hnet Δt Δθat : is the section factor of the steel beam/ part of the beam [m-1] : is the design value of the net heat flux per unit area [W/ m2] : is the time interval, taken as 30 sec. o : is the increase of the ambient temp. during the time interval Δt [ C] 12

θt o : is the ambient gas temperature at time t [ C] o θat : is the steel temperature [ C] Net heat flux: The net heat flux can be defined as the design value of the net heat flux per unit area in accordance with 3.1 of EN 1991-1-2 hnet hnetc hnetr hnetc hnetr c ( t Em Ef at ) 5.67 10 8 t 273 4 at 273 4 Where:hentc : is the convective heat flux hentr : is the radiative heat flux Em : is the surface emissivity of the member Ef : is the emissivity of the fire άc : coefficient of heat transfer by convection Calculation model: For the fire check calculation, the model used is the strength domain. In this model the temperature of the cross section after a given time is calculated based on the user inputs. Depending on the design temperature the reduced capacities of the cross sections are calculated and compared with the applied effects at the fire limit state in accordance with section 4 of EN 1994-1-2. Strength reduction factors: The strength reduction factors for concrete and steel are calculated in accordance with Table 3.3, and Table 3.2 of EC4 based on the design temperature. Plastic neutral axis & Moment of resistance: The plastic neutral axis and moment of resistances of the composite beam at the fire limit state is calculated in accordance with clause 4.3.1 along with Annex E of EC4. Vertical shear resistance: For the calculation of vertical shear resistance of the structural steel section the method given in E4 of Annex E is used. Longitudinal shear resistance: The longitudinal force and resistance are obtained by a similar procedure described in clause 6.6.6 of EN 1994-1-1, with reduced strength parameters. 13

References 1. Eurocode 4 (BS EN 1994-1-2) Design of composite steel and concrete structures Part-1-2. General rules- Structural fire design 2. Eurocode 4 (BS EN 1994-1-1) Design of composite steel and concrete structures Part-1-1. General rules and rules for building 3. Eurocode 3 (BS EN 1993-1-2) Design of steel structures Part-1-2. General rules- Structural fire design. 4. Eurocode 1 (BS EN 1991-1-2) Actions on structures Part-1-2. General actions - Actions on structures exposed to fire. 14