CITY OF DANA POINT WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS

Similar documents
WINDOW AND DOOR REPLACEMENT SAMPLE PLAN

Building Department Informational Handout. Residential Window Replacement Requirements

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,

One and Two Family Additions

HOW TO USE THIS GUIDE:

General Residential Code Requirements

General Residential Code Requirements

General Residential Code Requirements

FRAMING INSPECTION GENERAL

Minimum Requirements for Residential Occupancy Codes and FAQs

BUILDING PERMIT APPLICATION

RESIDENTIAL BUILDING REQUIREMENTS

Data Accuracy. Below Ground Finished* Square Footage: Measured below ground level as it appears from the front view of the building.

Excerpts from: International Residential Code 2009

2018 IRC Sections R303 through R310 Building Planning II

Adult Family Home Inspections

Village of Glen Ellyn Basement Remodeling Project Guidelines

City of Santa Monica Building and Safety Division

2003 International Residential Building Code

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

Comparison of the IRC and IEBC in Relation to One- and Two- Family Dwellings and Townhouses

Inspection Checklist Residential Building Final July 2016

EGRESS WINDOWS st Ave. NE East Bethel, MN Phone: (763) Fax: (763)

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES

CTC MEETING #25 CHILD WINDOW SAFETY REPORT

2012 IRC Sections R303 R310 Building Planning II

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

By James Tente, MCP, CBO,CFM

2012 Code Update Training

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

RESIDENTIAL STAIRWAYS, HANDRAILS,

Milgard Windows & Doors. Training Module Building Codes and Ratings

* RESIDENTIAL PLAN REVIEW *

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS

Single Family Dwelling Documents Preparation and Plan Review Guidelines California Residential Code (CRC).

2015 BUILDING CODES APPENDIX Q TINY HOUSES. Routt County Regional Building Department

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

APPLICATION FOR FINISHED BASEMENT PERMIT

Administrative Changes

RESIDENTIAL REMODELING AND BASEMENT FINISH

General Building Information

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

Pulaski County, Virginia

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

Residential Accessory Structures & Room Additions

Inspecting the Means of Egress Course

Typical Finished Basement Details

RESIDENTIAL BATHROOM REMODEL

SUMMARY OF RESIDENTIAL CODE GENERAL PROVISIONS 2004 Florida Building Code

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

2003 INTERNATIONAL BUILDING CODE 521

Basement Renovation Guide For Residential Dwellings

R vertical and horizontal.

SITE PLAN SCALE: 1/8"=1'-0" NORTH

Continuing Certificate of Occupancy Pre-Inspection Checklist

IRC 2015 Significant Changes

INTERNATIONAL CODE INTERPRETATIONS

CHAPTER 24 GLASS AND GLAZING

Company Overview. Significant Code Changes Massachusetts State Building Code 9 th Edition (2015 International Code)

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Residential Bathroom Remodels

PRIOR TO ISSUE OF THIS PERMIT APPLICATION, REVIEW AND WRITTEN APPROVAL BY THE FOLLOWING TOWN DIVISIONS AND LISTED ALTERNATE AGENCIES ARE REQUIRED.

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth.

Residential Plan Review for New One and Two Family Dwellings

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

PLASTIC CHAPTER 26. SECTION 2602 DEFINITIONS Definitions. The following terms are defined in Chapter

PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT. Construction requirements for LOWER LEVEL DEVELOPMENT. in residential dwellings

CARBON MONOXIDE ALARMS

RESIDENTIAL ATTACHED CARPORTS BUILDING PERMIT REQUIREMENTS

Building Codes and Ordinances ARC 227

Advanced FBC: Significant Changes to the 5 th Edition (2014) Florida Building Code, Building and Residential. presented by

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

International Code INTERPRETATIONS

INTERIOR ENVIRONMENT

Development Services Department. Building Division Handout San Pablo, CA Ph: (510)

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

RENTAL HOUSING SAFETY PROGRAM INSPECTION CHECKLIST

FBC 5 th Edition. General. Update to the Florida Building and Residential Codes Updates to the Florida Building and Residential Codes

Plan Review Checklist-2015 International Residential Code

BATH REMODELS For One and Two Family Residences and Townhomes Not Exceeding 3 Stories

Town of Chili. building department 3333 chili avenue, Rochester, ny (585) fax: (585)

Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting and

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Chapter 11. Dwelling Units and Sleeping Units

Building Permit For new construction projects

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board.

International Code Council

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

The permit holder is ultimately responsible for compliance with all aspects of the building code.

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code.

RESIDENTIAL PLAN CHECK LIST

General Requirements for Mobile Homes

Requirements for Additions/Enclosed Deck/Finished Bonus Room/Dormer

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

Transcription:

CITY OF DANA POINT COMMUNITY DEVELOPMENT BUILDING AND SAFETY 33282 Golden Lantern, Suite 209 Dana Point, CA 92629 949 248-3594 www.danapoint.org WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS 2016 CALIFORNIA CODES CODE CYCLE 01/01/2017 EFFECTIVE DATE INTRODUCTION The following information is provided as a guide for detached One-and-Two family dwelling window replacements and new installations using the 2016 California Residential Code. Within the City of Dana Point, all window and exterior door replacements require a building permit regardless of how they are classified. This includes both Retrofit Windows and New construction flanged windows. All window permits will require a floor and/or plot plan and a window schedule to accompany the application. Planning review and approval is required prior to permit issuance. In areas with a Home Owner s Association (HOA), approval from the HOA is also required. The plan must show the locations of the existing windows and the replacement windows size and type. The plan must identify the rooms associated with the window replacements and all sleeping room rescue egress must be clearly identified. Any changes to an existing non-compliant egress window will trigger compliance with the current applicable code dimensional requirements. ENERGY REQUIREMENTS Replacement window installations, without a Performance Energy Analysis, shall comply with the Mandatory Measures Prescriptive requirements. High Performance Windows are required, reducing the U Factor down to 0.32 and the SHGC down to 0.25 per the 2016 California Energy Code Section 150.1(c)3A. WINDOW SCHEDULE A window schedule shall be provided on the plan listing the window sizes, egress components, U Factor, SHGC and any tempered glass requirements. VERY HIGH FIRE HAZARD SEVERITY ZONE For properties located within the Very High Fire Hazard Zone, the new and/or replacement windows shall be of tempered glass. For vinyl frame windows, the corners shall be of a welded construction with a metal reinforcement. When installed, skylights and sloped glazing must be of tempered glass or other approved and tested materials and meeting the requirements of the Class A Assembly. Please note, most plastic skylights and plastic sloped glazing do not meet the fire resistive requirements of the code. To install plastic skylights, the product must be listed, fire rated and tested by a nationally recognized testing laboratory. B030-WINDOWS Page 1

WINDOW INSTALLATION Approved corrosion-resistive flashings shall be installed shingle fashion in a manor to prevent entry of water into the wall cavity or structural framing components. All flashings shall be installed following the Window Manufacturer s Instructions and ASTM 2112 and AAMA installation guidelines. For retrofit windows, the existing moisture barrier is not disturbed allowing the use of sealants and caulking. DOOR CONVERSIONS When changing an existing window to a sliding or French door or when adding a new door, the following additional elements and/or requirements shall apply: Landings are required at exterior doors. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed 1/4 unit vertical in 12 units horizontal (2-percent). Landing elevations at the required egress doors shall not be more than 1/2 inches lower than the top of the threshold. Exception: The exterior landing or floor shall not be more than 7-3/4 inches below the top of the threshold provided the door does not swing over the landing or floor. When exterior landings or floors serving the required egress door are not at grade, they shall be provided with access to grade by means of a ramp in accordance with Section R311.8 or a stairway in accordance with Section R311.7. Exterior lighting required. A switch and light is required outside each outdoor entrance or exit. Installation of a new door will change the electrical receptacle layout within the room serviced by the door. Compliance of the minimum distances between outlets will apply. When moving the electrical wiring to allow a new door and adding the required lighting requires an electrical permit and inspection. SMOKE ALARMS AND CARBON MONOXIDE Interior and exterior alterations, repairs or additions having a valuation in excess of $ 1,000 or when one or more sleeping rooms are added or created, the entire dwelling shall be provided with Smoke and Carbon Monoxide alarms per CRC Section R314 and R315. Smoke Detectors shall be installed in the following locations: In each sleeping room. Outside each separate sleeping area in the immediate vicinity of the bedrooms. On each additional story of the dwelling, including basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. When more than one smoke alarm is required to be installed within an individual dwelling unit the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the individual unit. Exception: Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic, basement or crawl space, and no previous method for interconnection existed. B030-WINDOWS Page 2

Carbon Monoxide Alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. An approved Carbon Monoxide Alarm shall be installed in dwelling units and in sleeping units within which fuel-burning appliances are installed and in dwelling units that have attached garages. Smoke Detectors shall be installed in the following locations: Inside sleeping units within which fuel burning appliances are installed. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). On every level of a dwelling unit including basements. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit. Exception: Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic, basement or crawl space, and no previous method for interconnection existed. EMERGENCY ESCAPE AND RESCUE OPENINGS - R310 Basements, habitable attics and every sleeping room shall have at least one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency escape and rescue shall be required in each sleeping room. The following outlines the minimum dimensions for egress compliance: The bottom of the clear opening is not greater than 44 inches measured from the finished floor to the clear opening, and The minimum net clear opening area of 5.7 square feet is provided, and Exception: Net clear opening space of 5 square feet is allowed for windows at grade level. (R310.2.1) The net clear opening height of 24 inches is provided, and Net clear opening width of 20 inches is provided. Please note that all four of the above elements are required for egress compliance. While some windows may appear to be compliant when considering the overall opening size, window style and fixed window dimensions may render the open element to not comply. Casement windows without egress hinging may decrease the opening size as the window opens. All considerations must be given to egress window sizing. GLAZING R308 Glazing installed in windows and doors shall meet the hazardous locations requirements as specified in CRC R308.6.2. Laminated, Tempered or other approved safety glazing is required in the following locations: Glazing adjacent to doors R308.4.2: Glazing in individual fixed or operable panels adjacent to a door where the bottom exposed edge of the glazing is less than 60 inches above the floor or walking surface and it meets either of the following conditions: Where the glazing is within 24 inches of either side of the door in the plane of the door in a closed position. Where the glazing is on a wall perpendicular to the plane of the door in a closed position and within 24 inches of the hinge side of an in-swinging door. Glazing in windows R308.4.3: Glazing in an individual fixed or operable panel when all of the following conditions apply: The exposed area of an individual pane is larger than 9 square feet, and The bottom edge is less than 18 above the floor, and The top edge is more than 36 inches above the floor, and B030-WINDOWS Page 3

One of more walking surfaces located within 36 inches measured horizontally and in a straight line of the glazing. Glazing adjacent to stairs and ramps where the bottom edge of the glazing is less than36 inches above the plane of the adjacent walking surface of stairs, landings and ramps. (R308.4.6) Glazing adjacent to the landing at the bottom of a stairway where the glazing is less than 36 inches above the landing and within 60 inches horizontally of the bottom tread. Glazing in walls, enclosures or fences facing hot tubs, spas, whirlpools, saunas steam rooms, bathtubs, showers and indoor/outdoor swimming pools where the bottom edge of the glazing is less than 60 inches measures vertically above the standing or walking surface. OPERATIONAL CONSTRAINTS Emergency escape and rescue openings shall be maintained free of any obstructions other than those allowed by this section and shall be operational from the inside of the room without the use of keys, tools or special knowledge. ADDITIONAL REQUIREMENTS The following details the additional requirements that apply to windows: Window wells. The minimum horizontal area of the window well shall be 9 square feet, with a minimum horizontal projection and width of 36 inches. The area of the window well shall allow the emergency escape and rescue opening to be fully opened. Exception: The ladder or steps required by Section R310.2.3.1 shall be permitted to encroach a maximum of 6 inches into the required dimensions of the window well. Ladder and steps. Window wells with a vertical depth greater than 44 inches shall be equipped with a permanently affixed ladder or steps usable with the window in the fully open position. Ladders or steps required by this section shall not be required to comply with Sections R311. 7 and R311.8. Ladders or rungs shall have an inside width of at least 12 inches, shall project at least 3 inches from the wall and shall be spaced not more than 18 inches on center vertically for the full height of the window well. Bulkhead enclosures. Bulkhead enclosures shall provide direct access to the basement. The bulkhead enclosure with the door panels in the fully open position shall provide the minimum net clear opening required by Section R310.3.2 Bulkhead enclosures shall also comply with Section R311.7.10.2. Bars, grilles, covers and screens. Bars, grilles, covers, screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings, provided the minimum net clear opening size complies with Sections R310.1.1 to R310.1.3, and such devices shall be releasable or removable from the inside without the use of a key, tool, special knowledge or force greater than that which is required for normal operation of the escape and rescue opening. The release mechanism shall be maintained operable at all times. Where the opening of the operable window is located more than 72 above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 (36 for other R- occupancies per CBC1015.8) above the finished floor surface of the room in which the window is located. Operable sections of windows shall not allow passage of a 4 inch diameter sphere where such openings are located within 24 inches of the finish floor.r312.2 All habitable rooms shall have windows with their total areas equaling at least 8% of the room s floor area and with their total opening area equaling at least 4% of the room s floor area. All windows require a permanent California Energy Commission Certification label. Bay windows and similar assemblies require the manufacturer s listed installation instructions for permit issuance. (UL, ICC, or equivalence) B030-WINDOWS Page 4

TYPICAL OPENABLE WINDOW DIAGRAM MINIMUM WINDOW SIZE FOR 20" CLEAR WIDTH 41" CLEAR 20" CLEAR OPENABLE AREA = 5.7 SQ. FT. 34 1/8" CLEAR OPENABLE AREA = 5.7 SQ. FT. MINIMUM WINDOW SIZE FOR 24" CLEAR HEIGHT 24" CLEAR 44" MAXIMUM BOTTOM OF SILL THE HEIGHT NET CLEAR OPENING FROM FINISH FLOOR EMERGENCY ESCAPE AND RESCUE WINDOW (EGREE) EGRESS SAMPLE WIDTH / HEIGHT REQUIREMENTS FOR EMERGENCY ESCAPE AND RESCUE (Dimensions are inches) WIDTH 20 20.5 21 21.5 22 22.5 23 23.5 24 24.5 25 25.5 26 26.5 27 HEIGHT 41 40 39.1 38.2 37.3 36.5 35.7 34.9 34.2 33.5 32.8 32.2 31.6 31 30.4 WIDTH 27.5 28 28.5 29 29.5 30 30.5 31 31.5 32 32.5 33 33.5 34 34.5 HEIGHT 29.8 29.3 28.8 28.3 27.8 27.4 26.9 26.5 26.1 25.7 25.3 24.9 24.5 24.1 24 Note: Using both the minimum sizes for width and height will not obtain the required minimum area (5.7 sq. ft.) The above chart shows the minimum area for a given width or height. This area is larger than the minimum required for ventilation. B030-WINDOWS Page 5