This document is downloaded from the Digital Open Access Repository of VTT. VTT P.O. box 1000 FI VTT Finland

Similar documents
SOFI FILTER Self-cleaning microfilter from 1 µm

FOR MINERAL AND MINING SLURRIES WITH HIGH SOLIDS CONCENTRATION

BOKELA HiBar Filtration

CAVITATION EROSION STUDY IN DEIONIZED WATER CONTAINING ABRASIVE PARTICLES

This document is downloaded from the Digital Open Access Repository of VTT

Properties of sonochemically treated Libyan kaolin pozzolan clay

MITIGATION OF FOULING ON HOLLOW FIBER MEMBRANE USING ULTRASONIC TRANSDUCER. A Thesis. Submitted to the Faculty. Purdue University.

GENERATION OF POWER MEGASONIC ACOUSTIC WAVES IN SUPERCRITICAL CO 2

5.3: FILTRATION NOOR MUHAMMAD SYAHRIN BIN YAHYA

Lab. Analytical Services

DESIGN AND OPERATION OF POROUS METAL CROSSFLOW MICROFILTERS

Starch Dewatering by Hi-Bar Filtration

Crossflow Filtration for Ink Jet Fluids

BOKELA DYNO Filter. Dynamic Crossflow Filtration. 02/ 2018 en

Welding characteristics and structures of same and different metal specimens using ultrasonic complex vibration welding equipments

HUBER Vacuum Rotation Membrane VRM Bioreactor

Sahar Mhiyo Faculty of Chemical and Petroleum Engineering, Al Baath University, Homs PO Box 77, Syria

Separation / Classification / Concentration Murata Kogyo Co., Ltd. Hydrocyclone Separation System. FT Associates

Analytical Services REV D

Reinhard Bott; Thomas Langeloh; Jurgen Hahn BOKELA GmbH, Karlsruhe, Germany. 1. Introduction

Foam-aided sludge treatment

Surface conditioning by ultrasonic wet peening

Advanced Manufacturing Choices

Ultrasonically enabled Low Temperature Electroless and Immersion Metallisation. AmirahKassim

Abstract. 1. Introduction. 2. Testing methodology. Early stage cavitation erosion within ceramics An experimental investigation

Economical dewatering of tailings for mine backfill with high performance disc filters

ANTI FOULING INVESTIGATIONS WITH ULTRASOUND IN A MICROSTRUCTURED HEAT EXCHANGER

Clean Manufacturing Tutorial: Abrasion Basics for Contamination Control. To minimize particles, understand abrasion

Proven solutions in ore processing

Technical White Paper

Ceramic Ultra Filtration with Zero Liquid Discharge Better Water, Safer Water, Lower Cost. Purification Capability. Applications

Reduced sludge Increased gas yield Improved dewatering Improved CO2 footprint

Study on Separation of Water and Alumina Fine Particles by Cross-Flow Microfiltration

Aspects of modelling in compressible filter cake formation

PES INSTITUTE OF TECHNOLOGY - BANGALORE SOUTH CAMPUS (Hosur Road, 1KM before Electronic City, Bangalore ) Department of Mechanical Engg.

Pretreated biomass improves digestion

BOKELA GmbH. Ingenieurgesellschaft für Mechanische Verfahrenstechnik. Centre of Excellence for Solid/Liquid Separation.

Selecting the right Equipment for your Sludge. Testing in the Lab. Charles Laughton - Euroby Limited

Worldwide Pollution Control Association

WAT-E Physical and Chemical Treatment of Water and Waste Filtration. Adjunct Prof. Riina Liikanen

The DYNO Filter. 12 / 2012 e

THEORY AND PRACTICE OF FILTRATION IN THE ALUMINA INDUSTRY

Synthesis and Characterization of α-alumina Membrane Support and Effects of Binders

SINTERED WIRE MESH.

Direct Metal Printers. Metal Additive Manufacturing with the ProX DMP Series

Destruction Mechanism of ZnAl4 as Cast Alloy Subjected to Cavitational Erosion Using Different Laboratory Stands

THE TRUE PORE SIZE OF TEXTILE FILTER MEDIA AND ITS RELEVANCE FOR THE FILTRATION PROCESS WITH RESPECT TO THE INTERACTION WITH APPARATUS AND SUSPENSION

Cavitation mechanism of ultrasonic melt

SINGLE-STAGE FILTRATION WITH SINTERED METAL TUBULAR BACKWASH FILTERS

A Publication of the Lubrication Engineers Technical Department LEADERS IN LUBRICANTS NUMBER 62

Outotec Non-ferrous Solutions

Experimental Investigation of Adsorption-Flocculation-Microfiltration Hybrid System in Wastewater Reuse

DIRECT METAL PRINTERS. Metal Additive Manufacturing with the ProX DMP Series

Filtration and separation technology. Product range. Automatic backwash filter. Selfcleaning scraper filter. Cake filtration

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

COMBINATION FILTRATION OF PRESSURE, VACUUM AND CLARIFICATION TECHNOLOGIES FOR OPTIMUM PROCESS SOLUTIONS (INCLUDING DATA IN APPENDIX A)

CYCLOSIZER. For Sub-Sieve Sizing SEPOR INC 718 N. FRIES AVE P.O.BOX 578 WILMINGTON, CA PHONE: FAX :

Heat Flow Meter HFM 436 Lambda. Analyzing & Testing

EFFECT OF COMPACTING PRESSURE ON INTERCONNECTED POROSITY IN IRON PM COMPACTS

FULLY AUTOMATIC TRIAXIAL TESTER (T-5001/A) ASTM D2850 D4767 D7181

WALCOOM. Walcoom Corporation SINTERED MESH.

REDUCTION OF CHROMITE FINES IN SOLID STATE USING A MIXTURE OF GASES CONTAINING NATURAL GAS, HYDROGEN AND NITROGEN

Development of a Prefiltration Membrane Technology: Integral Multiple-Zone LifeASSURE PLA Series Filter Cartridges

Laser and hybrid laser welding of thick stainless steels

POREX Tubular Membrane Filter (TMF ) Applied in Copper/Nickel Wastewater Treatment System for an Electroplating Industry Park

New process for improved dry scrubbing efficiencies in aluminium smelters

ABEL HM. Hydraulic Piston Diaphragm Pumps Reliable under high pressure and increased flow rates

Particle characterization of Metal Powders with Dynamic Image Analysis

This document is downloaded from the Digital Open Access Repository of VTT. P.O. box 1000 FI VTT Finland VTT

Mott All-Metal Catalyst Recovery Systems High-strength, high-efficiency filtration of particulate

Advance View Proofs. The Effect of Ultrasonic Treatment on Microstructural and Mechanical Properties of Cast Magnesium Alloys

Rethinking dispersion

CATALYST FILTRATION for the Chemical Processing Industry using Mott LSI Backwash Filter Media

DELKOR FP FILTER PRESS. It pays to talk to a specialist. for the mining and metals industries.

CeraMem. Ceramic Membrane Technology. Advanced Heavy Metals Removal System WATER TECHNOLOGIES

OUTOTEC INDUSTRIAL WATER TREATMENT

Abstract. Introduction CMP FILTER CHARACTERIZATION WITH LEADING SLURRY PARTICLES. Authors: Yi-Wei Lu, Bob Shie, Steven Hsiao, H.J.

WASTE MINIMIZATION WITH POROUS METAL BACKWASH FILTERS

Submerged Membrane Technology for MBR

Unique porous media. Process filtration expertise. Limitless possibilities.

Mitton Industrial Cavitation Reactor Systems. Using Cavitation to Reclaim our World s Water

Metal Powder - the Raw Material of Future Production

Vibratory shear enhanced membrane process and its application in starch wastewater recycle

CV GEDE DARMA PUTRA. Head Office Jln. Cihanjuang km 2,5 No.124 Cihanjuang, Parongpong Bandung, West Java, Indonesia. Phone

INTENSIFICATION THE PROCESS OF WATER PURIFICATION BY HYDRODYNAMIC CAVITATION

BHS-FILTRATION INC. BHS VACUUM BELT FILTER, CANDLE & PRESSURE PLATE FILTER TECHNOLOGIES FOR BIO-ENERGY APPLICATIONS

LAB FILTRATION SYSTEMS & EQUIPMENTS

Preparation of Ceramic Composite Membranes for Protein Separation

SIZE REDUCTION TECHNOLOGY

Maintain optimal flux chemistry to minimize excess zinc usage

Fabric Filtration. Typical Dimensions Dirty gas flows into page 11/6/2015. EVE 402 Air Pollution Generation and Control. Chapter #5 Lectures (Part 6)

Research Article Experimental Study of the Ultrasonic Vibration-Assisted Abrasive Waterjet Micromachining the Quartz Glass

Heating Iron Ore Slurry to Improve Filtering Efficiency Prior to Pelletizing

THE USE OF ULTRASOUND TO ACCELERATE THE ANAEROBIC DIGESTION OF WASTE ACTIVATED SLUDGE. Ewa Neczaj, Joanna Lach

Have you been plagued by Scale? WE have a new SOLUTION for YOU!

ISO INTERNATIONAL STANDARD

Available online at Universal Research Publications. All rights reserved ISSN

Transcription:

This document is downloaded from the Digital Open Access Repository of VTT Title Ultrasound assisted cleaning of ceramic capillary filter Author(s) Pirkonen, Pentti; Grönroos, Antti; Heikkinen, Juha; Ekberg, B. Citation Ultrasonics Sonochemistry - in press Date 2009 URL http://dx.doi.org/10.1016/j.ultsonch.2009.10.016 Rights Copyright 2009 Elsevier B.V. This article may be downloaded for personal use only VTT http://www.vtt.fi P.O. box 1000 FI-02044 VTT Finland By using VTT Digital Open Access Repository you are bound by the following Terms & Conditions. I have read and I understand the following statement: This document is protected by copyright and other intellectual property rights, and duplication or sale of all or part of any of this document is not permitted, except duplication for research use or educational purposes in electronic or print form. You must obtain permission for any other use. Electronic or print copies may not be offered for sale.

Article to special issue of Ultrasonic Sonochemistry ULTRASOUND ASSISTED CLEANING OF CERAMIC CAPILLARY FILTER Pirkonen, P*., Grönroos, A*., Heikkinen, J*. and Ekberg, B**, * Technical Research Centre of Finland (VTT) ** Larox Oyj, Finland Key words: ultrasound, cake filtration, cleaning, ceramic filter Abstract Research in the fields of filtration and dewatering connected with the use of ultrasound (US) has been carried out mainly with small laboratory-scale batch or continuously operating devices. So far the only large scale industrial cake filtration applications have been developed and manufactured by Larox Oyj for mining industry. These applications apply ultrasound for cleaning of ceramic capillary action elements having at maximum total filtration area of approximately 150 m 2. Several hundreds of filter units have been delivered worldwide during the past two decades. 1. Introduction A wide range of studies has been carried out to enhance membrane and particle filtration by utilising ultrasound technology. Studies have been performed mainly in lab or pilot scale, but only very few applications have been proceed to large commercial use. The efforts have been focused on changing suspensions properties to more favourable for filtration and or preventing fouling substance to stick the filter surface or cleaning the filter element itself. Combinations of ultrasound, electric field and washing chemicals have been used [1]. Only four applications which are worth mentioning are electro-acoustic dewatering press (EAD), CERTUS- polishing filter, Scamsonic screening filter and CERAMEC-ceramic capillary MF-filter [1,2,3]. The two cases mentioned the latest have found industrial use. In this paper the development of ultrasound cleaning of CERAMEC-filter will be presented as a case story. General issues dealing with the applying of ultrasound will also be viewed. 2. Ceramic capillary filtration Ceramec filter discs (Fig. 1a) are patented sintered alumina membranes with micropores that create strong capillary action in contact with water. This microporous filter medium allows only liquid to flow through (Fig. 1b). Filtrate is drawn through the ceramic discs as they are immersed into the slurry bath, and a cake forms on the surface of the discs. Despite an almost absolute vacuum, no air penetrates the filter media (Eq. 1). Consequently, Ceramec filters require only a small (2.2 kw-cc 45 and 7.5 kw-cc144) vacuum pump to transfer filtrate from the discs to the filtrate receiver. This is in strong contrast to conventional vacuum filters that have high air flow through the filter cake,

and need a large vacuum pump. Filter cake is removed from the ceramic discs by scrapers, eliminating the need for compressed air snap blow off [2]. The pore diameter for the air flow through the plate can be calculated by the Young-Laplace Law: D = 4 cos ( )/ P (1) surface tension for water (N/m) P bubble point pressure (N/m 2 ) wetting angle D pore diameter (m) The pressure difference needed to draw water out of capillary is presented in table 1. As an example 1.4 bar (= 140 kpa) pressure difference is needed to get water through a capillary having 2 µm pore diameter [2]. 3. Ultrasound assisted cleaning of ceramic filter element The physical effects of acoustic cavitation derive from the formation, growth and implosive collapse of bubbles in liquids irradiated with high-intensity ultrasound that produce intense local heating and high pressures with very short lifetimes. Cavity collapse near a solid surface becomes non-spherical, drives high-speed jets of liquid into the surface, and creates shockwave damage to the surface. Cavitation and shockwaves produced during ultrasonic irradiation of liquid-powder slurries can accelerate solid particles to high velocities [4]. Microscopic contaminants are best removed by lower frequency ultrasound, while submicroscopic contaminants are often best removed by ultrasound at higher frequencies [5]. Ultrasound has been used for cleaning a variety of materials from dental instruments to steel strip. Ultrasonic cleaning generally uses a frequency in the range of 16 70 khz (Fig. 2) [6]. Higher frequencies, on the order of 400 1000 khz, have been used very successfully in the silicon wafer industry to clean microscopic particles from wafer surfaces. With higher frequency cleaning, acoustic streaming (a large scale movement of fluid), plays a significant role in particle removal. For frequencies in the ultrasonic range, cavitation events and associated shock waves, microstreamers, microstreaming and micro-jets are important in the cleaning of particle-fouled surfaces (Fig. 3) [7, 8]. The predominant fouling mechanisms observed with ultrafiltration and microfiltration membranes are classified into three categories: the build-up of a cake layer on the membrane surface, blocking of membrane pores, and adsorption of fouling material on the membrane surface or in the pore walls. Acoustic streaming mechanism causes bulk water movement toward and away from the membrane cake layer, with velocity gradients near the cake layer that may scour particles from the surface. When a cavitation bubble is near a cake layer surface, microstreaming will result in a dynamic velocity profile that will exert drag forces on particles leading to removal. Micro-jets are formed when a cavitation bubble collapses in the presence of an asymmetry (i.e., a surface or another bubble). During collapse, the bubble wall accelerates more on the side opposite to a solid surface, resulting in the formation of a strong jet of water with an estimated velocity of 100 200 m s 1. The effective range of micro-jets is on the order of the bubble diameter. The high velocity of micro-jets could effectively scour particles from a membrane surface [7].

Ultrasound assisted cleaning of ceramic filter elements is performed together with back flushing with filtrate or with washing chemical solution (Fig. 4a). Back flushing removes residual cake and cleans the microporous structure. Backflow washing is automatic and adjustable for each application. Examples of possible Langevin type ultrasound transducers which could be installed inside the transducer box are presented in Fig. 4b. US transducer boxes are located between all the ceramic filter discs (Figs 4c and d). Cleaning phase is started when the capacity of filter has dropped below the set value. During the cleaning phase slurry basin is filled with water. Alternatively pulsed ultrasonic cleaning is carried out using the slurry in the filter basin as cleaning medium. In Fig. 5 an example of the effect of ultrasound in a pilot filter filtering iron ore is shown [2, 9]. 4. Development of ultrasonic transducer elements The success in ultrasound assisted cleaning requires excellent transform of electric energy to mechanical vibrations in such a way that erosion of transducers is minimal and electric efficiency is maximal. Planning, design and high quality manufacturing is needed. Long list of issues to be taken care of is needed in the development work: properties of basic ceramic vibrating discs, assembling of individual transducer units, transducer box material, way of connecting ceramic elements to the transducer box, properties of suspension to be filtered, ultrasound frequency, etc Impedance analyzer is a good tool to check the electrical properties of the individual transducer elements and transducer boxes (Fig. 6). Scanning laser vibrometer creates proper animation and gives also other info about the quality of vibration of the designed and manufactured transducer surface (Fig 7). Manufactured transducer boxes should also be tested with long term runs in the suspension to be filtered (Fig. 8a). Testing will straight reveal the errors in design of transducer box and severe erosion may appear (Fig. 8b) [9]. The durability of the ultrasonic transducers is important. Good service life can be achieved by using more cavitation resistant materials or by improving the manufacturing methods to minimize variations in the products. It is also important to achieve an even cleaning of the whole surface of the filter elements and therefore the ultrasound emission intensity from the ultrasonic transducer surface has to be well controlled. 5. Application of ceramic filters The capillary action dewatering system is exceptionally efficient for applications in the mining industry. The filter disc material is resistant to most chemicals, and it has a long operational life. Ceramec filters are best suited for dewatering of slurries with high and consistent concentration of solids having the major part of the particles in the size range 30-150 microns, The Ceramec filter technology is used widely for dewatering base metal concentrates, ferro chrome and iron ore products. Areas of application concentrates: Copper, Nickel, Zinc, Lead and Pyrite. The biggest machine is CC-144 which has filtration area of 144 m 2 (Tab. 2). Industrial installation can also include several Ceramec units (Fig. 9). Several hundreds of filter units have been delivered worldwide during the past two decades. The benefits of Ceramec filters are: very low energy consumption, dry filter cake, particle free filtrate, high filtration rates simple installation, operation and maintenance, integrated filter and ancillaries system, continuous operation, and high availability [10].

6. Future prospects Ultrasonic cleaning of filter elements is an important issue in capillary action filtration in order to keep the filtration rate on a high level. Further development aims at finding ways to obtain maximum cleaning efficiency especially in processes with changing conditions. To achieve this development of methods for on-line measurement and adjustment of the ultrasound efficiency during filtration must be developed. Literature [1] P. Pirkonen. Ultrasound in filtration and sludge dewatering, Advances in Sonochemistry vol. 6, Ultrasound in environmental protection (eds. Mason, T. and Tiehm, A.), Jai Press Amsterdam (2001) 221-246. [2] Larox Ceramec Filters, Larox Corporation 2007. [3] Scamsonic filter 2009, www.priorindustries.com/brochures/brochure_1.pdf. [4] K. S. Suslick et al., Acoustic cavitation and its chemical consequences. Phil. Trans. R. Lond. A 357 (1999) 335-353. [5] D. H. McQueen, Frequency dependency of ultrasonic cleaning, Ultrasonics, Volume 24 Issue 5 (1986) 273-280. [6] E. Harman and J. Lamm, The Impact of Ultrasonic Frequency on Particle Removal, Branson Ultrasonics Corp.). [7] M. O. Lamminen et al., Mechanisms and factors influencing the ultrasonic cleaning of particlefouled ceramic membranes, Journal of Membrane Science 237 (2004) 213-223. [8] M. O. Lamminen et al., Cleaning of particle fouled membranes during cross-flow filtration using an embedded ultrasonic transducer system, Journal of Membrane Science 283 (2006) 225-232. [9] A. Grönroos, P. Pirkonen, H. Kyllönen, SOME APPROACHES TO THE SCALE UP OF ULTRASONIC PROCESSING BY VTT IN FINLAND Special Session of ICA in Madrid 2-7 th September 2007 on High power ultrasound in large-scale sonochemical reactors". [10] Filtration Solutions for Mining and Metallurgy, Ceramec Capillary Action Disc Filters 2006, www.larox.com

Table 1. The pressure difference needed to empty pores of different diameters. Surface tension of 0.070 N/m and cos ( ) = 1 have been used [2]. D, µm 8 4 2.5 2.3 2 1.5 1 0.5 0.3 P, kpa 35 70 112 122 140 187 280 56 933

Table 2. Properties of different Ceramec capillary filters [2]. Model CC-6 CC-15 CC-30 CC-45 CC-60 CC-144 Av. power usage (kw) 4 9 14 17 27 70 Installed power (kw) 6.4 14.5 28 30 44 110 Basin volume (m 3 ) 1.7 3.1 5.2 7.4 9 35 Weight (ton) 4 7.1 9.8 13.8 15.1 34 Height (mm) 2600 2700 2700 2750 3000 4780 Width (mm) 3050 3300 3300 3300 3420 5900 Length (mm) 2700 4050 5600 7040 8750 8570 Filtration area (m 2 ) 6 15 30 45 60 144

Ceramic filter Substrate Filter cake (a) (b) Figure 1. a) Examples of Ceramec filter plates, (b) basic idea of Ceramec filtration [2].

Figure 2. Cavitation strength vs. ultrasound frequency [6]. Figure 3. Possible mechanisms for particle removal/detachment observed with ultrasonic cleaning [7].

(a) (b) US transducer boxes between the discs US transducer boxes Filter disc Generator (c) (d) Figure 4. a) Principle of ultrasonic cleaning, (b) examples of possible Langevin type ultrasound transducers which could be installed inside the transducer box, c) and d) placing of transducer boxes in the filtration machine [2, 9].

Filtration capacity with and without US Capacity, kg/m 2 h 4000 3500 3000 2500 2000 1500 Without US With US (2 min every 2 hours) 1000 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Time, h Figure 5. Filtration capacity as a function of time with and without pulsed ultrasonic cleaning in a pilot scale capillary action filter. The length of the ultrasonic pulse is 2 minutes and the interval is one hour.

Impedance, 1000000 100000 10000 1000 100 10 Impedance Phase shift 90 70 50 30 10-10 -30-50 -70 Phase shift, Deg. (a) 1 25 26 27 28 29 30 31 32 33 34 35 Frequency, khz (b) -90 Figure 6. a) Impedance analyzer, b) impedance and phase shift figures as a function of US frequency [9].

(a) (b) Figure 7. a )Scanning laser vibrometer, b) height of surface vibrations in a transducer box [9].

(a) (b) Figure 8. a) Long term testing of ultrasound transducer boxes, b) erosion of ultrasound transducer box [9].

Figure 9. Industrial installation of Ceramec capillary filters which have ultrasonic cleaning system [10].