Code Compliance Research Report CCRR 0270

Similar documents
Code Compliance Research Report CCRR 0241

Code Compliance Research Report CCRR-0266

Code Compliance Research Report CCRR-0234

Code Compliance Research Report CCRR-0164

Code Compliance Research Report CCRR-0208

Code Compliance Research Report CCRR-0153

Code Compliance Research Report CCRR-0137

Code Compliance Research Report CCRR-0187

Code Compliance Research Report CCRR-0194

Code Compliance Research Report CCRR-0228

Code Compliance Research Report CCRR 0277

Code Compliance Research Report CCRR-0118

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0163

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0131

Code Compliance Research Report CCRR-0257

Code Compliance Research Report CCRR-0238

Code Compliance Research Report CCRR-0262

Code Compliance Research Report CCRR-0101

Code Compliance Research Report CCRR-0106

Code Compliance Research Report CCRR-0238

Code Compliance Research Report CCRR-0171

Code Compliance Research Report CCRR-0163

Code Compliance Research Report CCRR-0225

Code Compliance Research Report CCRR-0185

Code Compliance Research Report CCRR 0232

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Code Compliance Research Report CCRR-0225

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

Code Compliance Research Report CCRR-0114

Code Compliance Research Report CCRR-0186

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

Code Compliance Research Report CCRR-0231

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: INTEPLAST GROUP CORPORATION EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

ATI Evaluation Service A Division of Architectural Testing Certification Services

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

ESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

ATI Evaluation Service A Division of Architectural Testing Certification Services

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

Advantage ICF System Product Information Bulletin

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Code Compliance Research Report CCRR-0176

(800) (562) A Subsidiary of the International Code Council

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

Code Compliance Research Report CCRR-0205

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

Code Compliance Research Report CCRR-0223

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING REPORT HOLDER: SILCA SYSTEM

ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

ICC-ES Evaluation Report Reissued October 1, 2010 This report is subject to re-examination in two years.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Joint Evaluation Report ICC-ES (800) (562)

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

ICC-ES Evaluation Report Reissued November 2014 This report is subject to renewal November 2016

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

Exterior Portfolio & Haven Insulated Vinyl Siding TER No

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

Contents. ZIP System R-Sheathing

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

EVALUATION REPORT Firestone Building Products 525 Congressional Blvd. Carmel, IN 46032

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

Transcription:

Code Compliance Research Report CCRR 0270 Issued: 12 22 2017 Revised: 01 17 2018 Renewal Due: 12 22 2018 DIVISION: 06 WOOD, PLASTICS, AND COMPOSITES Section: 06 65 00 Plastic Trim DIVISION: 07 THERMAL AND MOISTURE PROTECTION Section: 07 65 00 Flexible Flashing REPORT HOLDER: Deco Flash, LLC. 4717 Oak Fair Blvd. Tampa, FL 33605 (813) 397 2827 www.deco FLASH.com info@deco flash.com REPORT SUBJECT: DECO FLASH Flashing Systems 1.0 SCOPE OF EVALUATION 1.1 This Research Report addresses compliance with the following Codes: 2015 International Building Code (IBC) 2015 International Residential Code (IRC) 2017 Florida Building Code (see Section 9.0) 1.2 DECO FLASH has been evaluated for the following properties: Wind Driven Rain Surface Burning Physical Properties 1.3 DECO FLASH Flashing Systems are utilized in rough openings prior to the installation of windows and doors. DECO FLASH is to be installed on buildings of combustible, nonfire resistance rated construction: Type VB of IBC and FBC, and construction types permitted under the IRC and FBC R. 2.0 STATEMENT OF COMPLIANCE DECO FLASH Flashing Systems comply with the Codes listed in Section 1.1, for the properties stated in Section 1.2 and uses stated in Section 1.3, when installed as described in this report, including the Conditions of Use stated in Section 6.0. 3.0 DESCRIPTION 3.1 DECO FLASH Flashing Systems are a decorative, trim, flashing system installed in rough openings for windows and doors. Deco Flash is made of mono extruded polyvinyl chloride (PVC) profile, plastic welded on all four corners to form a DECO FLASH box unit. The Deco Flash unit has nailing fins and varying jamb returns. 3.2 The DECO FLASH units are provided in several section profiles, and identified in the following series: Builders Series, FC Series, J Series, and MF Series. See Figures 1 through 4 for dimensions. 4.0 PERFORMANCE CHARACTERISTICS 4.1 When installed in accordance with this report, DECO FLASH Flashing Systems meet the requirements of Section 1403.2 of the IBC and FBC for resistance to winddriven rain when tested in accordance with ASTM E 331 at a minimum differential pressure of 6.24 psf for a duration of 2 hours. 4.2 DECO FLASH PVC material complies with Section 2605.2 of the IBC and FBC for use as an exterior plastic veneer. Materials used in the DECO FLASH Flashing Systems have been shown to have a self ignition temperature greater than 650 F when tested in accordance with ASTM D 1929, a smoke development index less than 75 when tested in accordance with ASTM D 2843, and a combustibility classification of CC1 when tested in accordance with ASTM D 635, demonstrating compliance with Section 2605.2 and 2606.4 of the IBC and FBC.

Code Compliance Research Report CCRR 0270 Page 2 of 9 5.0 INSTALLATION 5.1 The DECO FLASH Flashing Systems shall be installed in accordance with the manufacturer s published installation instructions, the applicable Code, and this Research Report. A copy of the manufacturer s instructions shall be available on the jobsite during installation. 5.2 The Deco Flash units may be installed in exterior wall openings of wood frame, or concrete masonry. See Section 6.0 for Conditions of Use. 5.2.1 Wood Framed Construction: 5.2.1.1 DECO FLASH units may be installed on woodframed exterior walls sheathed with wood structural panels complying with Section 2303.1.5 of the IBC and FBC or Huber s Zip System Wall Sheathing (ICC ES ESR 1474). 5.2.1.1.1 Where sheathed with wood structural panels, a water resistive barrier complying with ICC ES AC38 shall then be installed over the exterior wall, and overlap the nailing fin of the Deco Flash unit. All seams shall be taped with self adhering flashing tape complying with AAMA 711. Prior to installing the water resistive barrier, head flashing complying with AAMA 711 shall be applied over the Deco Flash nail fin at the head, extending a minimum of 4 inches beyond the DECO FLASH unit to the left and the right. 5.2.1.2 Apply two continuous beads, minimum 3/8 inch, of ASTM C920 compliant sealant behind the nailing flange of the Deco Flash profile. One bead shall be applied along the back of the nailing flange in line with the fasteners. A second continuous bead of sealant shall be applied directly to the exterior face, 1 inch from the edge of the rough opening. 5.2.1.3 The DECO FLASH unit shall be fastened directly to exterior sheathing using minimum 1 inch nails, corrosion resistant as specified in the IBC and FBC. Fasteners are to be spaced approximately 2 inches from each corner and at 8 inches on center around the perimeter of the unit. 5.2.2 Concrete Masonry: exterior face, 1 inch from the edge of the rough opening. After the Deco Flash unit is installed, apply a continuous bead of sealant along the perimeter edge of the unit. 5.2.2.2 The DECO FLASH unit shall be fastened directly to exterior concrete masonry using minimum 1 1/4 inch corrosion resistant masonry fasteners. Fasteners are to be spaced approximately 2 inches from each corner and at 8 inches on center around the perimeter of the unit. 5.2.2.3 Masonry wall shall be waterproofed and damp proofed in accordance with the building code up to and including the interface with the DECO FLASH flange. 5.3 Conventional shims shall be used for the shim space between outside jamb of the Deco Flash and the inside edge of the rough opening. The shim space shall not exceed ¼ inches. 6.0 CONDITIONS OF USE 6.1 Installation must comply with this Research Report, the manufacturer s published installation instructions, and the applicable Code. In the event of a conflict, this report governs. 6.2 The anchorage of windows and doors is outside the scope of this report, and must be designed and specified by the window or door manufacturer. Windows and doors shall anchor to the supporting structure and be designed in accordance with the required design pressures specified in Chapter 16 of the IBC and FBC. 6.3 Fire resistance rated construction is outside the scope of this report. 6.4 The concrete masonry walls shall be designed in accordance with Chapter 21 of the IBC and FBC. 6.5 The DECO FLASH units are manufactured under a quality control program with inspections by Intertek Testing Services NA, Inc. 5.2.2.1 Apply two continuous beads, minimum 3/8 inch, of ASTM C920 compliant sealant behind the nailing flange of the Deco Flash profile. One bead must be applied along the back of the nailing flange in line with the fasteners. A second continuous bead of sealant must be applied directly to the

Code Compliance Research Report CCRR 0270 Page 3 of 9 7.0 SUPPORTING EVIDENCE 7.1 Reports of testing in accordance with ASTM E 331 00(2009), Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference, demonstrating compliance with Section 1403.2 of the IBC and FBC, and Section R703.1 of the IRC. 7.2 Reports of testing demonstrating compliance with ICC ES AC227, Acceptance Criteria for Rigid Cellular PVC Nonload Bearing Exterior Trim (revised June 2012), for weathering, mechanical fastener, and flame spread properties. 8.0 IDENTIFICATION The DECO FLASH is identified with the manufacturer s name (Deco Flash), and the Intertek Mark as shown below, and the Code Compliance Research Report number (CCRR 0270). 9.0 FLORIDA BUILDING CODE 9.1 Scope of Evaluation: DECO FLASH Flashing Systems have been evaluated for compliance with the Florida Building Code Building and Florida Building Code Residential. 9.2 DECO FLASH Flashing Systems have been additionally evaluated for weathering resistance of plastics with outdoor exposure when tested to ASTM G 155 and ASTM D 2565 for a period of 4500 hours and subsequent testing demonstrating compliance with FBC Section 2614.2. 9.3 Conclusion: The DECO FLASH, described in Sections 2.0 through 7.0 of this Research Report, comply with the Florida Building Code Building and Florida Building Code Residential, including the High Velocity Hurricane Zone provisions of the Florida Building Code Building and the Florida Building Code Residential. 10.0 CODE COMPLIANCE RESEARCH REPORT USE 10.1 Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 10.2 Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product by Intertek. 10.3 Reference to the https://bpdirectory.intertek.com is recommended to ascertain the current version and status of this report. This Code Compliance Research Report ( Report ) is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.

Code Compliance Research Report CCRR 0270 Page 4 of 9 FC418 J418 Retro Figure 1 Builders Series

Code Compliance Research Report CCRR 0270 Page 5 of 9 FC45 FC65 FC75 Figure 2 FC Series

Code Compliance Research Report CCRR 0270 Page 6 of 9 J45 J65 J75 Figure 3 J Series

Code Compliance Research Report CCRR 0270 Page 7 of 9 MF65 Figure 4 MF Series

Code Compliance Research Report CCRR 0270 Page 8 of 9 Figure 5 Wood Frame Installation MAXIMUM 0.25" GAP

Code Compliance Research Report CCRR 0270 Page 9 of 9 Figure 6 Concrete Masonry Installation MAXIMUM 0.25" GAP