Performance Considerations of the Thermal Envelope Moderator: Mike Adkins, United States Cold Storage

Similar documents
Gregory W. Stevens and Ronald K. Ishii, Alternative Energy Systems Consulting, Inc.

The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario

Application Specification:

6. Moisture Design. Objectives: 3. Prevent vapor condensation (surface, concealed) 4. Prevent rain penetration

PLYCEM SX20/20 MODULAR BUILDING INDUSTRY FLOOR SYSTEM PLYCEM SX20/20 MODULAR BUILDING INDUSTRY FLOOR SYSTEM

TECH SOLUTIONS THERMAX Insulation in Low Humidity Metal Buildings

1. Frozen food warehouses used solely for storage of Class I and II commodities where protected by an approved automatic sprinkler system.

NIBS AIR BARRIERS. Washington, DC October 26, 2010 Update on Standards Wagdy Anis, FAIA, LEED AP Wiss, Janney, Elstner, Assoc., Inc.

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

INSULATED METAL PANELS INSMP2A 1LU/HSW HOUR Prepared and presented by MBCI

JRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE

Thermal Bridging in Residential Construction

Chilled Beams. The new system of choice?

Building Envelopes 101

Moisture risks of passive retrofitting one town house for the adjacent conventional neighboring structures

ENERGY ANALYSIS AND ENERGY CONSERVATION OPTION FOR THE WAREHOUSE FACILITY AT THE HUMAN SERVICES CENTER COMPLEX DRAFT REPORT.

NRCC Guarded Hot Box Testing (ASTM C ) for Energy Efficiency of a Total Roof Assembly

New Approaches to Energy Efficiency & Green Building. Who is Icynene Inc.? World-Wide Distribution. The Icynene Insulation System

Thermal Bridging and Whole Building Energy Performance

Emperor Penguins and Efficient Buildings. Resisting frigid temps with thermal breaks.

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

BUILDING ENCLOSURE AIR TIGHTNESS TESTING Course Number: BCLUNA018-01P

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

ROOT VEGETABLE STORAGE WAREHOUSES

International Code Council. ICC XX Public Input Agenda based on input received on Initial Draft

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

CAE 331/513 Building Science Fall 2017

Analysis of the air conditioning systems in a blown films manufacturing plant in the southeastern United States

Foil Back Gypsum Board

Corium Brick Rainscreen System Specifications

Why Insulate? - Thermal Control Certified Faced Insulation acts as a barrier to slow down the movement of heat, keeping it inside the building in wint

SECTION STAINLESS STEEL WALL PANELS

1 Exam Prep Florida Building Code-Energy Conservation Edition Tabs and Highlights

STAYCELL APPLICATION GUIDE

TECH NOTES INSULATING SOLUTIONS: THERMAX TILT WALL FIT OUT. THOMCO, Inc

Insulation in Low Profile Cross Ventilated Freestall Facilities TAKE HOME MESSAGES

Code Compliance Research Report CCRR-0228

CEN/TC 89 - Thermal performance of buildings and building components

GA GYPSUM BOARD TYPICAL MECHANICAL AND PHYSICAL PROPERTIES

Spray Foam Requirements for thermal barriers and ignition barriers in the IRC. Presenter

Condensation - Prevention and Control

INSULATION VALUES TECHNICAL BULLETIN Vol. 3, No. 1 JANUARY 2017

1 of 17. PO Box Bellevue Rd, Newark, DE V F

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

INSULATED METAL PANELS COLD STORAGE

Residential Energy Code Combustion Air and Make-Up Air

Roof & Deck Insulation / PLA BuyLine Insulation Systems for. Roofing Applications

MONITORING AND DATA COLLECTION FOR DISTRIBUTED GENERATION/ COMBINED HEAT AND POWER (DG/CHP) SYSTEMS AT ALLIED FROZEN FOODS BROCKPORT, NEW YORK.

III. Economics. A. General Page III-2 B. Initial Capital Costs Page III-3 C. Life Cycle Costs Page III-4

NC 2009 Residential Code changes (Highlights on changes between the 2006 and 2009 NC Residential Code)

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

AIA PRESENTATION. Insulated Metal Panels

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Technical Reference. Portfolio Manager ENERGY STAR. Parking and the ENERGY STAR Score in the United States and Canada OVERVIEW

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

Farm Energy IQ. Farm Energy Efficiency Principles 2/16/2015. Farm Energy Efficiency. Basic Energy Principles

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

Introducing TJ Insulated Structural Framing Components

INSULATED METAL PANELS COLD STORAGE

ROOFING INSTALLATION GUIDELINES

IECC Commercial Significant Changes Summary Tier I

Hardin County Planning and Development Commission

Michigan Energy Code Training and Implementation Program

Thermal Performance of Nvelope NV1 Clip System

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

Activity 2.2.3A Heat Loss and Gain (Revised)

White Paper WP007. Cover 10/13. Energy Codes and Precast Concrete in Colorado. Energy Codes and Precast Concrete in Colorado WP007 WP007

Chapter 4. Analysis of Building Energy Performance

Gerald R. Ford Museum

Energy Auditing for Schools. Maryland Energy Administration Eric Oliver, EMO Energy Solutions, LLC May 10, 2007

(Project Location) (your firm's name)

KNIGHT WALL SYSTEMS GUIDE DETAILS:

Farm Energy IQ. Farms Today Securing Our Energy Future. Farm Energy Efficiency Principles Tom Manning, New Jersey Agricultural Experiment Station

Assessment of Building Energy Performance for EEMs A Case Study in Mumbai

Technical Report 2. Bellevue Ambulatory Care Pavilion New York, NY. Building and Plant Energy Analysis

Air Sealing for 5 ACH 50

This article will address the test methods used to determine R-values and their relative degree of accuracy.

O82018 Hunter Panels XCI Foil

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

Caribbean Hotel Energy Efficiency Action (CHENACT)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

4. Insulation of external walls

INNOVATION. TECHNOLOGY. SOLUTIONS. INSULATED PANELS SEE THE DIFFERENCE in appearance, value, performance and installation.

currently referenced throughout the

Bridging on Building Envelope Performance. A Whole Building Energy Perspective

Chapter 6. Space heating load

ICC xx Standard for Spray-applied Polyurethane Foam Plastic Insulation

Metal Buildings and Condensation. Welcome to Metalcon Condensation Description. Program Objectives. Dew Point Temperatures

KS SERIES - VERTICAL INSTALLATION

Transcription:

Performance Considerations of the Thermal Envelope Moderator: Mike Adkins, United States Cold Storage Panelists: Andy Bowser, Team Group Larry Gilliland, SubZero Constructors Jay Smith, Metl-Span

Recommended Design Values Area Description Wall Panel Thickness Wall R-Value Roof Insul. Thickness Roof R-Value Dry Warehouse 3" 24 3" 18 +50 F Coolers 3" 24 4" 25 +45 F Cooler/Dock 4" 32 6" 38 +32 F to +40 F Cooler 4" 32 6" 38 +28 F Cooler/Freezer 4" 32 7" 44 0 F Freezer 5" 40 8" 50-10 F Freezer 5" to 6" 40 to 48 8" 50-20 F Freezer 6" 48 9" 56 Note: R-Values shown are "conditioned" aged values.

Freezer Building Example We will look only at the Transmission loads for the maximum design conditions of the building (variable). Product loads (constant). Refrigeration fan motors (constant). Lighting heat (constant). Infiltration (constant). Material handling equipment (constant). Other loads (constant). 3

Freezer Building - Transmission Loads Only Components of the Transmission or Envelope Heat Loads: Heat flow through wall panels. Heat flow through the roof or ceiling may be up to 50% of total envelope loads. Heat flow through the floor insulation. 4

Freezer Facility Assumptions -20 F ice cream storage freezer. 24,000 sq. ft. facility (150 x 160 ). Approximately 21,700 sq. ft. of wall panels. 35 high. +34 F dock adjacent to freezer. Two doors between freezer and dock. Exterior design temperature of 90 F. Temperature difference is 110 F. Based on the maximum design load condition. 5

Impact of Panel Thickness 4 thick urethane core insulated panel K-factor, Btu in/ft² hr F @ 40 F mean core temperature = 0.126 1/K x t = R (8 per inch of panel thickness) R = 32 for 4 panel T / R = Q At 110 F T and Q = Btu/ hr. ft² Q = 3.44 Btu/hr. ft² 6

Impact of Panel Thickness 5 thick urethane core insulated panel K-factor, Btu in/ft² hr F @ 40 F mean core temperature = 0.126 1/K x t = R (1/K=8 per inch thickness) R = 40 for 5 panel T / R = Q At 110 F T and Q = Btu/ hr. ft² Q = 2.75 Btu/hr. ft² 7

Impact of Panel Thickness 6 thick urethane core insulated panel K-factor, Btu in/ft² hr F @ 40 F mean core temperature = 0.126 1/K x t = R R = 48 for 6 panel T / R = Q Q = Btu/ hr. ft² Q = 2.30 Btu/hr. ft² 8

Wall Panel Heat Flow Summary Panel Thickness in Heat Flow Btu/Hr. Ft² Wall Panel Area Sq. Ft. Total Heat Btu/Hr. 4 3.44 21,700 74,648 6.22 Tons per Hour of Refrigeration 5 2.75 21,700 59,675 4.97 6 2.30 21,700 49,910 4.16 Difference between 4 panel and 6 panel is approx. 2.06 tons per hour Note: 1 TR 12,000 Btu/Hr. 9

Refrigeration Loads Loads Tons per Hour Transmission Loads Walls 6 R48 4.16 Roof 8 R50 5.95 Floor 6 R30 4.67 Lights 4.40 People 0.36 MH Equipment 6.19 Product Load 18.75 Infiltration 27.43 Refrigeration Fans 3.80 TOTAL LOAD 75.71 10

Load Profile Required Capacity (Tons of Refrigeration) 0% 1% 3% 4% 30% 7% 21% 14% 9% 11% MOTORS PEOPLE OTHER FANS TRUCKS EXPERIENCE (10%) LIGHTS TRANSMISSION PRODUCT LOAD INFILTRATION 11

Transmission Load Load (Tons of Refrigeration) 4% 7% 46% 8% 8% WEST NORTH SOUTH EAST 27% FLOOR ROOF 12

Load Contributions Contributor Infiltration generally the largest contributor to the load in a busy warehouse Product value depends on product type, storage temperature and incoming temperature Envelope (Floor / Ceiling) values depends on climate, storage temperature Envelope (Walls) value depends on climate and storage temperature Other made up of motors, people, trucks, fan motors, lighting Impact 20-30% 0-30% 10-20% 5-10% 15-20% 13

Peak Energy Cost for Walls Tons of Refrigeration = 75.71 5 Hp/Ton of Refrigeration @ -20 F 378.6 Horsepower 282 Kwh (Hp x 0.7457 = Kw) 282Kwh x 24 Hours/Day x 30 Days 203,040 Kw/month @ $0.10/Kw = $20,304/month Note: This is based on 6 panel, 8 roof and 6 floor insulation.

Energy Cost Difference for 4 vs. 6 Tons of Refrigeration = 2.06 5 Hp/Ton of Refrigeration @ -20 F 10.3 Horsepower 7.68 Kwh (Hp x 0.7457 = Kw) 7.68 Kwh x 24 Hours/Day x 30 Days 5,530 Kw/month @ $0.10/Kw = $553

Energy Cost Comparison Electrical Rate per Kwh Cost for Total TR Cost for 4 vs. 6 $0.07 $14,213 $ 387 $0.10 $20,304 $ 553 $0.13 $26,395 $ 719 $0.15 $30,456 $ 830 $0.20 $40,608 $1,106 $0.25 $50,760 $1,383 Note: Values assume continuous maximum design conditions for month.

Return on Investment Electrical Rate per Kwh Increased Capital Cost for 2 Panel Monthly Electrical Savings for 6 vs. 4 Years for Payback $0.07 $36,890 $ 387 8.0 $0.10 $36,890 $ 553 5.5 $0.13 $36,890 $ 719 4.25 $0.15 $36,890 $ 830 3.75 $0.20 $36,890 $1,106 2.75 $0.25 $36,890 $1,383 2.25 Note: Values assume continuous maximum design conditions for month and a differential panel cost of $1.70/sq. ft. 17

Financial Comparison Electrical Rate per Kwh Increased Capital Cost for 2 Panel Monthly Electrical Cost for 4 vs. 6 Monthly Loan Amount for Capital $0.07 $36,890 $ 387 $282 $0.10 $36,890 $ 553 $282 $0.13 $36,890 $ 719 $282 $0.15 $36,890 $ 830 $282 $0.20 $36,890 $1,106 $282 $0.25 $36,890 $1,383 $282 Note: Values assume same as pervious slide and an interest rate of 4.5% over a 15 year amortization. 18

Panel Attachment Considerations Set the wall girt attachment elevations based on the span capability of the panel. Set the fastener pattern based on the wind load transfer at the girt line. Keep the panel s metal skins set at 26 gauge unless a change is required for other reasons. Watch corner conditions closely. 19

20

21

22

Considerations for Cavity Space Ventilation Above Ceiling Panels Dead air space promotes condensation. Still air begins to participate with the insulation and a dew point can develop. Moving air serves to keep air space temperature elevated for the same moisture levels in air. Recommend at least six volumetric air changes per hour in the cavity space. Relative humidity is relative it s the actual moisture in the air that matters. 23

Considerations for Temperature Pull-down Keep refrigeration set above freezing until moisture formation and condensation has stopped occurring. Keep refrigeration on for at least a week before going below freezing. Step the room down about 10 at a time and hold for two days at each step. Make provisions for pressure equalization. 24

California Title 24 Title 24 is California s Building Energy Efficiency Standards became effective for Refrigerated Warehouses on January 1, 2010. Section 126 addresses the energy efficiency of refrigerated spaces within buildings. A refrigerated warehouse with total cold storage and frozen storage area of 3,000 square feet or larger are subject to the Code. EXCEPTION 1: A refrigerated space less than 3,000 square feet must meet the Appliance Efficiency Regulations. EXCEPTION 2: Areas designed solely for the purpose of quick chilling or freezing of products with design cooling capacities of greater than 240 Btu/hr-ft2 (2 tons per 100 ft2). 25

Envelope Insulation Values MINIMUM TITLE 24 VS ASHRAE RECOMMENDATIONS SPACE SURFACE MIN R-VALUE TITLE 24 ( F hr ft²/btu) ASHRAE* ( F hr ft²/btu) Frozen Storage Roof/Ceiling R-36 R-35 to R-50 (below 32 F) Wall R-36 R-35 to R-40 Floor R-36 R-27 to R-32 Cold Storage Roof/Ceiling R-28 R-24 to R-40 (32-55 F) Wall R-28 R-24 to R-32 * ASHRAE Recommended R-Values (2010) Other restrictions are placed on mechanical equipment, lighting, and sub-floor heating (frost heave protection). 26

Owners Considerations for Performance Evaluation Thermal Performance Based on ASTM C-1363 Thermal Testing. System test based on actual application including full panels, clips and sealants. Structural Performance Based on ASTM E-72 Structural Testing. 27

FM4880 Combustible components such as foam when used in non-combustible construction has to meet the requirements of IBC chapter 26. To waive the thermal barrier requirement (i.e. gypsum) the product must meet testing standards of FM4880, UL1040 or NFPA286. 28

FM4880 Up to 2005 the FM4880 approval for exterior walls did not have structural testing requirements. FM4880 was a testing classification for fire protection only. 29

FM4881 FM4881 Standard was introduced in 2005 and sets structural performance requirements for all exterior wall systems including, but not limited to metal, concrete, composite and glass. This standard is required on all projects that are FM Global insured. 30

FM4881 Requires the use of Data Sheet FM 1-28 for calculating wind ratings. The design pressures are calculated based on FM Global Property Loss Prevention Data Sheet 1-28. A safety factor of 2 is applied to the design pressure to determine wind ratings which are published in increments of 5 PSF. 31

FM4881 Products that receive approval recognition have been evaluated to provide assurance that they will perform their intended functions and maintain the integrity of the building envelope for that stated design conditions. 32