Energy Efficiency Requirements 9.36

Similar documents
2014 British Columbia Building Code Changes

Public Notice New BC Building Code Requirements

Building Envelope

ILLUSTRATED GUIDE. Energy Efficiency Requirements for Houses in British Columbia. Climate Zone 4 Lower Mainland and Southern Vancouver Island

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

9.36 Energy Efficiency

SectIon Energy Effldency

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

Feature Zone IECC 2009 IECC

PART 9 ENERGY EFFICIENCY AND VENTILATION REQUIREMENTS (For Single and Two Family Dwellings)

2010 National Building Code Adoption and Associated Process Changes

Energy Compliance Information

Energy Compliance Information

Supplementary Standard SB-12. Energy Efficiency For Housing

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Secondary Suite This form is used for both existing and new construction of a secondary suite in an existing structure

Boulder City NV Prepared by (Print Name) Signature Date

OR LEGAL DESCRIPTION PLAN: BLOCK: LOT: APPLICANT / CONTACT:_ INSPECTION RESULTS TO BE MAILED TO THIS ? YES NO

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

FIELD COPY ATTACHMENT

Residential Buildings Energy Code Summary

Prescriptive Checklist for the 2015 Washington State Energy Code

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

9.36. Energy Efficiency

IRC 2012 Key Changes

Table Air Barrier and Insulation Inspection Component Criteria

Measure 1 Seal Ducts Components Inspected

Charter Township of Washington

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

Plan /Submission Requirements

A.ENVELOPE AIR SEALING

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

MID-CONSTRUCTION BLOWER DOOR TESTING February 15, 2017

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Presented by: Stephen Carr Regional Building Science Manager (386)

2015 IECC Air Sealing Multifamily For Code Compliance Funding for Energy Code Training

Rebates for Improvements Home Efficiency Program Fort Collins Utilities

SUSTAINABLE ENERGY ANALYTICS

WeatherSmart Air Barrier Installation Guide

Project Type: New Home Addition Alteration (Describe)

Michigan Energy Code Training and Implementation Program

IECC Residential Significant Changes Summary. Tier I

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

Hardin County Planning and Development Commission

2015 Michigan Residential Code Energy Worksheet for Single-family Additions, Alterations, Renovations and Repairs

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Air Sealing for 5 ACH 50

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

Please Submit Plans and Forms Electronically.

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Plan Check & Field Inspection Guide

2012 IECC Residential with State Adopted Changes

Supplementary Standard SB-12. Energy Efficiency For Housing

Presented by: Stephen Carr Regional Building Science Manager (386)

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

Initial House Assessments & Sealing Options:

Compliance Certificate

Work Order (Bid Form) Upper East Tennessee Human Development Agency, Inc.

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

Guidelines for Using HOT2000 with the Performance Path of the 2010 National Building Code of Canada Subsection

PICK YOUR POISON AND HOW TO GET THERE. Presented By Robby Schwarz

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

COMcheck Software Version Envelope Compliance Certificate

Success with 2009 IECC: Tech Tips for Builders. Insulation. Copyright 2014 Advanced Energy. All Rights Reserved

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

Changes. With respect to Energy efficiency 2006 Code is 22% better than 1997 Code Code 37% better than 1997 Code

New Hampshire Residential Energy Code

1) For the purpose of this Section, the term common space shall mean all spaces required to

Performance Requirements and Options in the International Energy Conservation Code. Mike Turns, Senior Program Manager

- Inbound/Outbound window placement - Window buck & air sealing - Weep holes IN THE WOODS DETAILS - WINDOW SILL

Compliance Certificate

Residential Requirements of the Texas Energy Code 2009 IRC Chap 11

SUBMISSION GUIDE FOR ARCHITECTS

INSULATION BATT (1) (2) Code Reference: 2016 Title 24, Reference Appendices RA3.5. Pressure or Friction Fit

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Air Sealing, Infiltration & Ventilation

New Construction Procurement Guidelines for the Pacific Northwest

BUILDING PERMIT APPLICATION NBC SECTION C1 - ENERGY EFFICIENCY COMPLIANCE FORM FOR ZONE 7A

SOUTHWEST ENERGY CODES CONFERENCE. This is how we do it! Getting to 3ACH50 and

Energy Code Basics for Residential Buildings. Presented by Newport Ventures NEWPORT VENTURES

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Energy Star Qualified - New Homes

ENERGY STAR Homes version 3 Designing and Building to Meet the 2011 Changes. Thursday, February 24, 2011

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

INSULATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

Required effective insulation values are available on information sheets for each climactic zone.

2009 IECC Chapter 1 Additions, alterations, renovations or repairs.

REScheck Software Version Compliance Certificate

Energy Efficiency For Housing

NAHB s Recommendations on Critical 2015 ICC Code Change Proposals

Work Order (Bid Form) Upper East Tennessee Human Development Agency

Standards for Jackson EMC s Right Choice Program Revised: June 2011

Transcription:

The following information has been obtained from the HPO Illustrated Guide, Energy Efficiency Requirements for Houses in British Columbia, BCBC 9.36 & 9.32, Building Officials Association of British Columbia and The Canadian Wood Council. 1

Skylight curbs are not required to be insulated. Before December 19, 2014 The above cross section indicates the typical framing with insulation being constructed prior to December 19, 2014 where the nominal insulation thickens determined the required R-value. 2

After December 19, 2014 9.36.2.4 now takes into account all of the assembly components including cladding, sheathing, framing, insulation and interior finish materials. This is known as Effective Insulation Effective Thermal Resistance taking the whole wall assembly into consideration. 3

A wall effective thermal resistance design calculator is available at http://cwc/wtd; a list of assembly s and their effective insulation values is available from the Canadian Wood Council site at the address listed. 4

Abbotsford is located in Zone 4 Prescriptive reductions for insulation values will apply for the walls, ceilings below attics and skylight shafts when an HRV is introduced into the home. 5

The RSI (R-value System International) can be multiplied by 5.678 to obtain the R-Value. Abbotsford is located in Zone 4, less than 3,000 Heating Degree Days; the above table indicates the required RSI values of the solid building assembly. 6

New code requirement zone 4: <3,000 DDC Eff. RSI 6.91 (R-39.23) with or without HRV Example The illustration incorporates R-40 Blown Cellulose insulation in Zone 4, with or without an installed HRV is compliant. Attached garages are treated as unconditioned space with no allowances for heat. The assembly (walls & ceilings) separating the garage from the conditioned space must be insulated and air tight. 7

Mechanical, electrical and plumbing components placed within an exterior wall must be insulated behind to the effective thermal resistance required for the above or below grade wall assembly. R-12 Roxall batts covering foam are acceptable. Thermal bridging of repetitive structural members (i.e. joist box ends, header spaces) must be included when calculating the thermal resistance of the exterior above grade wall assembly. 8

In the attic at the perimeter wall, the insulation value must maintain a minimum RSI value as the wall assembly for a maximum of 4. (In some designs the introduction of a high heeled truss may be warranted). Backer rod not to be used on exterior side. The space between the framing member and window / door frame may have the same effective U-value as the adjoining window / door. 9

The detailed illustration above indicates the Effective Insulation values required in a home constructed in Zone 4 not incorporating an HRV. 10

11

Illustrations below indicate permitted placement of insulation for unheated and heated floors and slab on grade assemblies. Insulation placement of Unheated Slabs Slab on grade at foundation wall with exterior insulation to the footing. Slab on grade at foundation wall with interior insulation down 1.2 m, or to the footing with a thermal break at the slab to the footing. Slab on grade at foundation wall with insulation in a 1.2 m perimeter under the slab with a thermal break. Insulation placement for Heated Slabs Exterior insulation to the footing and insulation under all heated slab areas. Interior wall insulation and insulation under all heated slab areas. 12

When insulation is separated by the building envelope as indicated above, the interior insulation side must extend down the wall 4 times the thickness of the wall. Junctions between the floor and rim joist, and rim joist to foundation must be sealed. Illustrations above indicate where potential leakage conditions occur and where sealing is required between all joints and junctions between the structural components, and/or covering the structural components with an air barrier material and sealing it to the adjacent air barrier material. 13

Flexible sheet air barrier materials require all joints to be: lapped at least 50 mm (2 ); sealed, and structurally supported. Sealants must be non-hardening. 14

Poly pans are required on exterior walls and ceilings for electrical boxes and pot lights, and must be sealed to the air/vapor barrier. Edges of poly pans to be structurally supported. The attic hatches and all electrical penetrations into the attic space along any gaps, spaces, penetrations, irregularities that could cause leakage must be sealed. Section 9.36 of the BCBC details all areas requiring attention to air leakage, the illustrations are a few of the most common areas of concern. 15

Section 9.36 of the BCBC details all areas requiring attention to air leakage, the illustrations are a few of the most common areas of concern. Example Window Label showing U-value The U-factor is a rating given to a window based on how much heat loss it allows. U-factors generally range from 0.2 (very little heat loss) to 1.2 (high heat loss). The U-factor is the inverse of the R-value of a window, which measures a window s insulating value. Thus, a high R-value is the same as a low U-factor, and means that a window does not allow much heat to escape. 16

Ducts must be insulated to the same level as required for walls if they are outside of the heated space and carrying conditioned air. Bathroom, dryer and kitchen exhaust are exempt from this requirement though are required to be directed directly outdoors, insulated to TSI 0.75 and have a vapor barrier. Transverse and longitudinal joints in duct work must be sealed using an approved tape or sealant when outside the heated space. 17

Heating Efficiencies Fabric tape is not approved in the BCBC for this application. Ventilation air intake Clothes dryer vent Combined supply and exhaust ventilator Exhaust and supply fans Required Required Required Required In general, ducts are required to be equipped with a damper. The damper may be gravity operated, motorized or spring loaded. Where motorized dampers are used, they must remain in an open position if damper operation fails, such as during power outages. 18

Exterior Roof Top Heat/Cool Unit Heating Efficiencies Interior Residential Gas Furnace HVAC equipment must be located inside the heated space. Only HVAC equipment designed strictly for outdoor installation can be located outside the heated space. Attached garages, even if heated are considered unconditioned space. 19

Heating Efficiencies Minimum Efficiency 92% Gas Fired Tankless 20

Heating Efficiencies Gas Fired Boiler Minimum Efficiency 90% Air Conditioners now have a 14.5 SEER rating (Seasonal Energy Efficiency Rating) Heat Pumps now must have an 11.5 Energy Efficiency Rating The efficiency ratings for gas furnaces, boilers and hot water tanks both storage and instantaneous have been adjusted in the new requirements. Air conditioners and heat pumps also have increased efficiency ratings. 21

Heating Efficiencies Gas Fired Tankless Instantaneous Gas Fired Storage HWT Electric Storage HWT The efficiency ratings for hot water tanks both storage and instantaneous have been adjusted in the new requirements. 22

Service Water Heating Piping Pipe insulation is required for the first 2 m (6.5 ft.) of the storage tank inlet and outlet. The insulation must be at least 12 mm (0.5 ) thick. In cases where piping is located outside the building enclosure or within unconditioned space, the insulation must be installed to a thermal resistance not less than the effective resistance requirements of the exterior above grade wall. In homes with recirculating hot water systems, all piping must be insulated. Heat recovery ventilation is not a requirement of Section 9.36. Where heat recovery ventilators are used, equipment must conform to the requirements of 9.36.3.9., including having a minimum sensible heat recovery efficiency of 60%. 23

9.32 Ventilation Pre December 19. 2014 the exhaust only systems were used where a fan (bathroom) was used to create a negative pressure within the space and ventilation air was achieved through air leakage from loose building construction. Post December 19, 2014 and with the introduction of a principal exhaust fan in 2006, the sizing was based on the number of bedrooms, the table above now indicates the number of bedrooms as well as floor area to determine the principal ventilation fan sizing. 24

The primary ventilation system is required to run continuously, this can be achieved by the use of an HRV or a dedicated Lo-Sone fan not exceeding 1.0 sones (noise level). 25

With 4 options to deliver ventilation air, utilizing the forced air system interlocking to the primary ventilation fan is cost effective in a majority of applications. The fresh air piping to the forced air return duct has also been reduced in length to the furnace cabinet and must not be located upstream of a return air grill. A 2 nd option is to incorporate a passive HRV as the primary ventilation fan; the furnace blower would be required to run continuously 24/7. 26

The 3 rd option is to incorporate an HRV as the primary ventilation system. The system is installed separately from the forced air system or as a standalone ventilation system when forced air is not being installed. The 4 th option is also installed separately from the forced air or as a system when forced air is not being installed. A primary ventilation fan is installed and interlocked with a distribution fan sized 2-3 times the primary ventilation fans capacity. The air discharge grill should be installed no closer than 2 m from the floor ensuring that the cooler air is mixed with tempered air maintaining a suitable 27

Should the calculation provided on the Mechanical Ventilation Check list provided by the HVAC installer indicate the collective exhaust appliances exceed the ½ air change per hour, make up air sized accordingly to the excess exhaust must be provided to the dwelling. Exhaust from bath fans, primary ventilation fans and range exhaust ducts must be vented directly out doors, insulated with an RSI of 0.75 (R-4) and have a continuous vapor barrier. 28