Characterization of the Corroded Surface Morphology of a Carbon Steel Piping Elbow Affected by Flow-Accelerated Corrosion

Similar documents
Flow Accelerated Corrosion Failures in Gas to Liquids Plant ( Methane Gas Reforming Plant) Tsepo Ndou Senior Metallurgist PetroSA South Africa

a)permanent address: The Institute of Applied Energy, Shinbashi SY Bldg. 8F , Nishi-Shinbashi, Minato-ku, Tokyo, , Japan

Critical Consideration on Wall Thinning Rate by Liquid Droplet Impingement Erosion

Integrity Evaluation for Elbows based on TES Collapse Load

Investigation on Flow Accelerated Corrosion Mitigation for Secondary Circuit Piping of the Third Qinshan Nuclear Power Plant

FLOW-ACCELERATED CORROSION IN NUCLEAR POWER PLANTS: APPLICATION OF CHECWORKS AT DARLINGTON

CNSC Reference # RSP-637.1

Development of Integrity Evaluation Program for Pipe Wall Thinning

NEW APPROACHES FOR FLOW-ACCELERATED CORROSION

Crack Initiation and Crack Propagation of Pre-corroded Ni-16Cr Alloy in 4.5%NaCl Aqueous Solution

E6) Study on the Corrosion of Steel and Zinc with Flow Velocity and Corrosion Control by the Vacuum Membrane Deaeration System in Tap Water

Microstructural analysis of thermal fatigue damage in 316L pipes

The Effect of Dissolved Oxygen on Stress Corrosion Cracking of 310S in SCW

Flow-Accelerated Corrosion in Pipe Wall Downstream of Orifice for Water and Air-Water Bubble Flows

Weld Root Measurement by ToFD for Inspection of Flow-Accelerated Corrosion Susceptible Welds

Determination of High-Risk Zones for Local Wall Thinning due to Flow-Accelerated Corrosion

Corrosion of structural materials and electrochemistry in high temperature water of nuclear power systems

Case Studies of Pulsed Eddy Current to Measure Wall Loss in Feedwater Heater Shells

AREVA NP > AREVA NP GmbH NTCMM-G, A. Zander, IAEA - Workshop on FAC and EAC; April 21-23, 2009; Moscow

Friction and Wear Properties of Copper/Carbon/RB Ceramics Composite Materials under Dry Condition

Development of New Structural Materials for Advanced Fission and Fusion Reactor Systems

DURABILITY AND TRIBOLOGICAL PROPERTIES OF THERMALLY SPRAYED WC CERMET COATING IN FULL FILM AND PARTIAL EHL CONTACTS

Hideout of Sodium Phosphates in Steam Generator Crevices

CORROSION BEHAVIOR OF AUSTENITIC AND FERRITIC STEELS IN SUPERCRITICAL WATER

Development of a LDIE Prediction Theory in the Condition of Magnetite Formation on Secondary Side Piping in Nuclear Power Plants

A Review on Flow-Accelerated Corrosion (FAC) in Fossil and Combined Cycle- HRSG Plants Bharatsinh Parmar Corresponding Author Address: ABSTRACT

PREVENTION OF SCC OCCURRING IN A EXPANSION TRANSITION REGION OF STEAM GENERATOR TUBING BY Ni-PLATING IN PWRS

Improvement of corrosion resistance of HVOF thermal sprayed coatings by gas shroud

High Energy Piping Inspection Program for Power Generation and Process Industries. For Regulatory Compliance, Safety, and System Longevity

A Review of Suitability for PWHT Exemption Requirements in the Aspect of Residual Stresses and Microstructures

DEVELOPING AND IMPLEMENTATION OF A FATIGUE MONITORING SYSTEM FOR THE NEW EUROPEAN PRESSURIZED WATER REACTOR EPR

Water Droplet Impingement Erosion (WDIE) Water Droplet Impingement Erosion (WDIE) Solid Particle Erosion. Outline

Intergranular Corrosion (IGC)

Effect of Additional Cu and Mg in Al-Mn-Si Alloy on Intergranular Corrosion Susceptibility After Heat-treatment at 473K.

Corrosion Behavior of Steam Turbine Materials for Geothermal Power Plants

Study of Failure of the Steam Tubes of Boiler Furnaces in Najebia Power Plant ABSTRACT Introduction

EFFECT OF LOCAL WALL THINNING ON FRACTURE BEHAVIOR OF STRAIGHT PIPE

by NISHIKAWA Hiroyuki, KATSUYAMA Jinya and ONIZAWA Kunio

Regulatory Perspective on CANDU Feeder Pipe Degradation due to FAC and IGSCC

Ultrasonic Monitoring of Corrosion with Permanently Installed Sensors (PIMS)

2. The BRT-CICERO software and its validation

Balance-of-Plant Corrosion

DEGRADATION MONITORING OF G.A. SIWABESSY RESEARCH REACTOR S SECONDARY COOLING PIPE

Ten Year Retrospective Look at HRSG FAC Assessment and Incidence. Peter S. Jackson, PhD, PE, David S. Moelling, PE, Mark Taylor, Mech. Eng.

+ economic + + flexible + + innovative + BENSON Boiler

A Case Study: Corrosion Failure of Tube Heat Exchanger

Prevention of SCC in the Expansion Transition Region of Steam Generator Tubing of PWRs by Ni-plating

Carbohydrazide A Hydrazine Replacement: 10 Years of Utility Experience

Compression characteristics of spheroidal graphite cast iron pipe members

Structural Integrity and NDE Reliability I

Non Destructive Inspection Technology for Thermal Power Plants

Effect of Distribution in Cross Sectional Area of Corroded Tensile Reinforcing Bars on Load Carrying Behaviour of RC Beam

Network Analysis of Turbine and Feedwater Systems of the Fugen Nuclear Power Plant

Case Study: Failure Analysis of Sulfuric Acid Supply Line

THE SCALLOPING PHENOMENON AND ITS SIGNIFICANCE IN FLOW- ASSISTED-CORROSION.

ACOUSTIC EMISSION FROM RUST IN STRESS CORROSION CRACKING

METER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA

HASTELLOY ALLOYS: SOLUTIONS TO SEVERE WET FLUE GAS DESULFURIZATION ENVIRONMENTS

Effect of Occasional Shear Loading on Fatigue Crack Growth in 7075 Aluminum Alloy M. Makizaki 1, a, H. Matsunaga 2, 4, b, K. Yanase 3, 4, c 3, 4, d

EXPERIMENTAL INVESTIGATION ON COOLING RATE FOR CENTRIFUGAL CASTING Kirti Kanaujiya, Yugesh Mani Tiwari Department of Mechanical Engineering

EFFECTS OF MECHANICALLY DRILLED PITS ON TENSILE DUCTILITY AND FRACTURE BEHAVIOR OF A STRUCTURAL STEEL

Application for Permission to Extend the Operating Period and Application for Approval of Construction Plans of Unit 3 at Mihama Nuclear Power Station

MEASURMENT OF THE FILM THICKNESS, FILM VELOCITY AND ENTRAINMENT FRACTION IN A LIQUID-AIR ANNULAR FLOW USING A CONDUCTANCE FLOWMETER

Observations of Corrosion Fatigue Crack Initiation Processes in Metals by Means of AFM

Evaluation method of corrosion lifetime of conventional stainless steel canister under oceanic air environment

EFFECT OF COPPER AND COPPER OXIDE ON CORROSION OF BOILER STEEL

PVP PVP EFFECTS OF WELD OVERLAYS ON LEAK-BEFORE BREAK MARGINS

LIFE ASSESSMENT OF HIGH PRESSURE STEAM PIPING BEND WORKING UNDER CONDITIONS OF CREEP DAMAGE. JUNEK Michal 1, JANOVEC Jiří 1

Microstructure Changes on T92 Steel after Accelerated Ageing Process at 654ºC

Development of Simulation Model of Chloride Ion Transportation in Cracked Concrete

Prediction of Residual Stress of U Bending Heat Transfer Tube of Steam Generator

ANALYSIS ON NON-UNIFORM FLOW IN STEAM GENERATOR DURING STEADY STATE NATURAL CIRCULATION COOLING

UNDERSTANDING OF WORK ROLL CORROSION AND OXIDATION IN A HOT STRIP MILL*

Erosion Behaviour of Stainless Steel Grade-316

Erosion-Corrosion Study of Oil-field Materials due to Liquid Impact

Oxidation Mechanisms in Zircaloy-2 - The Effect of SPP Size Distribution

Fukaya, , Saitama, Japan. Japan. Keywords: Water cavitation peening, Impact pressure, Arc height value, Residual stress

The Latest on ACC Corrosion Mechanisms The Lack of any Further Understanding

Contact rolling fatigue of rail steels

STUDY ON THE DURABILITY OF THERMALLY SPRAYED WC CERMET COATING IN PARTIAL EHL CONTACTS

Mechanisms for Boron Effect on Microstructure and Creep Strength of Ferritic Power Plant Steels

2. Feeder pipe wall thinning mechanism and design modifications

Stress Corrosion Cracking of Copper Alloys in Pure Steam

SIMS Analysis of Hydride in Commercially Pure Titanium

PRESSURE VESSELS Part III: Design Loads, Wind & Seismic, Skirts, Legs, Saddles, Nonstandard

Iron Oxide Scale Removal from Boiler Feed- Water in Thermal Power Plant by Magnetic Separation

Maintenance Technologies for SCC which Support Stable Operations of Pressurized Water Reactor Power Plants

NDE Based Finite Element Modeling & Analysis of Wall Thinning in CANDU Feeders

Evaluation of Young s modulus of thin coated layer on cold-rolled steel sheet

Investigation of shape recovery stress for ferrous shape memory alloy

Behaviour of Stress Corrosion Cracking of Austenitic Stainless Steels in Sodium Chloride Solutions

Research Projects VI. RESEARCH APPROACH

EFFECT OF THE POTENTIAL ON THE FILM COMPOSITION AND THE STRESS CORROSION CRACKING OF MILD STEEL IN AMMONIUM NITRATE SOLUTIONS

Patent Pending Drastically improved fatigue strength FA treated

Results are presented in Table 1. The tube was fabricated from a Type 347 and no unusual conditions were noted.

COOLING OF ROLLS USED IN HOT ROLLING OF LONG PRODUCTS

Analysis of micro-leak sodium-water reaction phenomena in a sodium-cooled fast reactor steam generator

High Temperature Oxidation Behavior of High Nitrogen 9%Cr Steels

A STUDY ON CORROSION MECHANISM OF FBR STRUCTURAL MATERIAL IN SMALL SODIUM LEAK UNDER INSULATOR

THE SIZE EFFECT ON FATIGUE STRENGTH OF STRUCTURAL STEEL MATERIALS IN HIGH-HUMIDITY ENVIRONMENT

Transcription:

E-Journal of Advanced Maintenance Vol.9-1 (2017) 26-32 Japan Society of Maintenology Characterization of the Corroded Surface Morphology of a Carbon Steel Piping Elbow Affected by Flow-Accelerated Corrosion Hiroshi ABE 1*, Yutaka WATANABE 1, Makoto NAKASHIMA 2, and Tadashi TATSUKI 2 1 Graduate School of Engineering, Tohoku University, 6-6-01-2, Aoba, Aramaki, Aoba, Sendai Miyagi, 980-8579, Japan 2 Research and Development Center, Tohoku Electric Power, 7-2-1, Nakayama, Aoba, Sendai, Miyagi, 981-0952, Japan ABSTRACT It has been widely recognized that the inner surface of carbon steel piping affected by relatively severe flow-accelerated corrosion (FAC) shows typical morphology in terms of roughness in many cases. Although hydrodynamic parameters would determine the characteristics of the rough surface developed in such cases, the detailed mechanism of the roughness formation is not fully known. In this study, the local FAC rate profile and morphology in terms of surface roughness for an entire 90-degree carbon steel piping elbow used in a fossil power plant have been investigated under two-phase flow in order to discuss the relationships between the FAC rate and characteristics of the inner surface morphology. For the axial direction, the FAC rate gradually increased with distance from the inlet, and it reaches the peak value in the downstream side, beyond which, the value kept decreasing slightly. Distributed horse-shoe pits and scalloped patterns were observed on the extrados side. The finding suggests that the extrados side of the pipe wall was covered with a continuous liquid film (single-phase). The result shows the possibility of the occurrence of FAC by a single-phase flow in the area where there is a sudden change in flow regime, even when the nominal phase state of the fluid is a two-phase flow regime. Both the local FAC rate and scallop coverage increase steeply near the middle parts of the elbow. There was a good correlation between the two, but it was not a one-to-one relationship because a significant decrease in FAC rate was observed in the downstream side; in contrast, the entire surface was covered with a fine scalloped pattern. The change in the morphology in terms of surface roughness clearly indicated that the overlapping of horse-shoe shaped pits gave a scalloped appearance. The results revealed that the inner surface shape affected by FAC is considered to essentially depend on the number density of nucleation sites for pit formation. KEYWORDS Pipe wall thinning, Flow-accelerated corrosion, Turbulence, Surface roughness, Scallop pattern, Horse-shoe pit, Carbon steel, Piping elbow, Fossil power plant ARTICLE INFORMATION Article history: Received 10 January 2017 Accepted 29 May 2017 1. Introduction Wall thinning in carbon steel piping, mainly caused by flow-accelerated corrosion (FAC), is recognized as a degradation issue that needs to be paid careful attention, particularly in the nuclear and fossil power industry. FAC usually becomes a problem in applications where there is a significant level of turbulence (e.g., elbows, downstream of an orifice, branch or junction pipes). The phenomenon of FAC is understood to proceed via the acceleration of chemical or electrochemical dissolution of the oxide layer under very fast mass transportation between the pipe wall and bulk water; there are a number of parameters that influence this process, including component geometry, water chemistry, material composition, and hydrodynamics [1-4]. Since the transport of ferrous ions to bulk water is widely recognized as the rate-limiting process in FAC, the driving force of the process is considered to be the concentration gradient of ferrous ions across the concentration boundary layer. The mass transfer coefficient, which is determined mainly by the hydrodynamic parameter, that affect the thickness of the boundary layer, resulting in a change in the concentration gradient of ferrous ion. It is widely recognized that the inner surface of carbon steel piping affected by relatively severe * Corresponding author, E-mail: hiroshi.abe@qse.tohoku.ac.jp ISSN-1883-9894/10 2010 JSM and the authors. All rights reserved. 26

FAC shows a typical morphology in terms of roughness in many cases; a scallop pattern or orange peel appearance is observed for a single-phase flow, while a tiger stripe appearance is commonly observed for a two-phase flow [5-8]. A scalloped pattern was also observed in experiments on the dissolution of pipes made of plaster of Paris [9, 10]. It is possible that surface roughness promotes the development of local turbulence that results in accelerating the FAC rate. It has been reported that the experimental mass transfer coefficient on a rough surface, which simulates a scalloped surface, seemed to be around 2-3 times that observed for a smooth pipe [11]. Although hydrodynamic parameters would determine the characteristics of the rough surfaces developed in such cases, the detailed mechanism of the roughness formation is not fully known. The authors recently have discussed the relationship between the FAC rate and surface roughness based on the characteristics of a scalloped appearance (scallop size, depth, and density) in a circumferential direction on the carbon steel piping elbow [12]; however, investigation of these characteristics in the axial direction (parallel to the flow direction) in consideration of the development of turbulence was not carried out because the size of the piping specimen was very limited. In this study, we investigate the local FAC rate profile and morphology in terms of surface roughness for an entire 90-degree carbon steel piping elbow used in a fossil power plant under two-phase flow. 2. Experimental 2.1. Sample information and operating conditions A 90-degree elbow component of an ascending pipe in an evaporator (deaerator) taken from a fossil power plant in Japan was used. The appearance of the sample is shown in Fig. 1. The inner surface shows a partly brown appearance on a black substrate due to surface oxidation and corrosion during long term storage in air. The surface has a shiny black appearance just after being removed. The outer diameter, the nominal piping wall thickness, and the radius of curvature are 140 mm, 6.6 mm, and 420 mm, respectively. The steel grade is carbon steel pipes for high temperature service (STPT410-S in JIS G 3456). The chemical composition of the sample and the history of the operating conditions for the region of interest are summarized in Tables 1 and 2, respectively. The phase state 100 mm Fig. 1. Appearance of the 90-degree elbow piping Table 1 Chemical compositions of the sample, wt% Steel grade C Si Mn P S Cr STPT410-S 0.10 0.27 0.62 0.012 0.007 0.028 Table 2 History of the operating conditions of the region of interest Duration of service 260,000 h (Approx.) Temperature (Drum water) 128 (Full load) Dissolved oxygen 1~2 ppb Flow rate (PV) 8.55m/s (Full load) Pressure 0.15MPa (Full load) Phase state Two-phase flow ph 9.0 (initial ~ 27% of duration) 9.3 (66% of duration) 9.6 (last 7% of duration) 27

has been estimated to be a two-phase flow; however, the information about a two-phase flow regime and void ratio were not available. The controlled ph value was increased in a step-by-step manner because of the change in water chemistry treatment to mitigate FAC. For example, high-avt (All Volatile Treatment with a high ph value without using hydrazine) was conducted in the last stages of the operation. 2.2. FAC rate and surface morphology evaluation The local FAC rate was obtained by dividing the loss in thickness by the operation duration. The extrados side half part of the piping, which shows significant loss in thickness compared with intrados side, was investigated. One half of the piping was cut into 12 parts in order to precisely measure the residual thickness using a dial caliper gauge of which needle head diameter is smaller than the size of scallops. The average value of 3 measurements which was selected randomly was adopted as the residual thickness. For the thickness measurement of scalloped surface parts, the bottom of scallops were measured. The morphology of the inner surface of the piping was observed by using an optical microscope. Detailed characteristics of the scalloped appearance (coverage of scallops, number density, and size) along the axial direction of the center of extrados were also investigated. The coverage of scallops was obtained from image analysis of a 15 mm square area in each measurement. The coverage of scallops was defined as the ratio of the area with scallops / (the area with scallops + the area without scallops). A single horse-shoe pit was also considered as a scalloped surface. The number density of scallops was obtained by counting the number of scallops or parts of scallops included in a 10 mm square area. The average length of long side of 3 scallops was adopted as the size of the scallop. 3. Results and discussion 3.1. Local FAC rate profile on the extrados side of elbow piping The local FAC rate profile on the extrados side of the elbow piping is shown in Fig. 2. For the location in axial direction, 0 mm and 800 mm correspond in position to 0-degree and 90-degree of the elbow, respectively. For the circumferential direction, a significantly higher FAC rate was observed at the center part of the extrados (0-degree). The FAC rate decreased linearly with distance from the Fig. 2. Local FAC rate profile on the extrados side of elbow piping 28

center of the extrados to the intrados side. The difference in the local FAC rate was caused by the difference in the hydrodynamic parameter, and was not due to the material or water chemistry. These local FAC rate profiles should correspond closely to the local turbulence level affected by the piping geometry. For example, it was clearly demonstrated that the actual FAC rate and estimated mass transfer coefficient showed a maximum on the intrados for the short-radius bend; in contrast, the maximum of the above parameters were observed on the extrados for the long-radius bend [13]. Additionally, local hydrodynamic conditions should be considerably complicated because of the two-phase flow. For the axial direction, the FAC rate gradually increased with distance from the inlet, and it reached the peak value in the downstream side, beyond which it continued to decrease slightly. This tendency also suggested the development of local turbulence from the upstream to the downstream side in the elbow piping. 3.2. Characteristics of the inner surface morphology The transition in the morphology in terms of surface roughness on the extrados piping is summarized in Fig. 3. A relatively smooth surface with a sparse distribution of horse-shoe pits was observed on the upstream side, and the density of the pits gradually increased toward the downstream side (Fig. 3 (b) and (c)). Overlapping of the pits was observed near the middle parts of the elbow, and on the downstream side, the entire surface was found to be covered with a fine scalloped pattern. No tiger striping pattern was observed. As mentioned above, the scallop pattern and horse-shoe pit are widely recognized as typical morphologies for corroded surfaces affected by significant FAC in a single-phase flow. The finding indicates that the extrados side of the pipe wall was covered with a continuous liquid film (single-phase) like a water slide. The result shows the possibility of the occurrence of FAC by a single-phase flow in the area where there is a sudden change in flow regime, even when the nominal phase state of the fluid is a two-phase flow regime. As shown here, characterization of the inner surface morphology can occasionally give important information to estimate the local flow regime. Fig. 3 also clearly indicates that the occurrence of overlapping horse-shoe shaped pits gives a scalloped appearance [14]. Although the detailed mechanism for the formation of horse-shoe pits is still unclear, our results have revealed that the inner surface shape of piping affected by FAC is considered to essentially depend on the number density of nucleation sites for pit formation. 3.3. Characteristics of the scalloped surface and its relation to the local FAC rate The profiles of the local FAC rate and coverage of the scallops along the center of the extrados in the axial direction with each 30 mm distance are shown in Fig. 4. The general FAC rate profile has already been explained in Fig. 2. The coverage of scallops increased from 0% (upstream) to 100% (downstream). Both the local FAC rate and coverage of scallops increase steeply in the region 300 to 400 mm away from the inlet of the elbow. Since there was a good correlation between the two, it seems that a significant acceleration in the FAC rate is possible due to scalloped surface formation. However, the local FAC rate and scallop coverage did not show a one-to-one relationship because there was a significant decrease in FAC rate observed in the downstream side; in contrast, the coverage of scallops was still maintained at 100%. The authors have already reported in another work that there was no significant increase in the FAC rate as a result of scallop formation although the local turbulence should increase by a hydrodynamic effect due to the formation of a scallop surface [12]. The profiles of the local FAC rate, number density, and size of the scallop are also shown in Fig. 5. The profile of the number density of scallops closely corresponded to the FAC rate profile. Both gradually increased with distance from the inlet, reached a peak at the same location, and then gradually decreased. The maximum size of the scallop (horse-shoe pit, in practice) shown in here was around 5 mm. The scallop size decreased with increasing FAC rate in the area most of which is covered with fine scallops. The inverse relationship between the FAC rate and scallop size corresponds to that observed in other findings, including examples from an actual power plant [15]. Fig. 5 also indicates that the FAC rate essentially corresponds to the number density of nucleation sites for pit formation, as mentioned above. 29

H. Abe, et al./ Characterization of the Corroded Surface Morphology Fig. 3. Transition in the morphology in terms of surface roughness on the extrados piping. (a): Overall appearance of the inner surface of the extrados side, (b)-(d): Enlarged figures of the white squares in (a), (e)-(g): Enlarged 3D figures of the blue squares in (b)-(d), the left and right indicate color map and height contour map, respectively. 30

0.18 100 FAC rate, mm/year 0.16 0.14 0.12 0.10 0.08 0.06 FAC rate Coverage of scallops 0.04 0 200 400 600 800 Location in the axitial direction, mm Fig. 4. Profiles of the local FAC rate and scallop coverage along the center of the extrados in the axial direction 80 60 40 20 0 Coverage of scallops, % 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 FAC rate Number density of scallop Size of scallop 0 200 400 600 800 Location in the axitial direction, mm Fig. 5. Profiles of the local FAC rate, number density and size of scallop 40 30 20 10 0 Number density of scallop, /cm 2 6 5 4 3 2 1 Size of scallop, mm 4. Conclusion The local FAC rate profile and morphology in terms of surface roughness were investigated for an entire 90-degree carbon steel piping elbow used in a fossil power plant under two-phase flow in order to discuss the relationships between the FAC rate and characteristics of the inner surface morphology. Our main findings are summarized as follows: 31

(1) Distributed horse-shoe pits and a scalloped pattern were observed on the extrados side. The finding suggests that the extrados side of the pipe wall was covered with a continuous liquid film (single-phase) like a water slide. The result shows the possibility of the occurrence of FAC by a single-phase flow in the area where there is a sudden change in flow regime, even when the nominal phase state of the fluid is a two-phase flow regime. (2) Both the local FAC rate and scallop coverage increase steeply near the middle parts of the elbow. Since there was a good correlation between the two, it seems that a significant acceleration in FAC rate was possible due to the formation of a scalloped surface. However, the local FAC rate and scallop coverage did not show a one-to-one relationship because a significant decrease in FAC rate was observed in the downstream side; in contrast, all of the surface was covered with a fine scalloped pattern. (3) The change in the morphology in terms of surface roughness clearly indicated that the overlapping of horse-shoe shaped pits gave a scalloped appearance. The results revealed that the inner surface shape affected by FAC is considered to essentially depend on the number density of nucleation sites for pit formation. References [1] L. E. Sanchez-Caldera: The Mechanism of Corrosion Erosion in Steam Extraction Lines of Power Stations, ASME Journal of Engineering for Gas Turbines and Power, Vol. 110, pp.180-184 (1988). [2] C. Cragnolino: Proc. 3rd Int. Symposium on Environmental Degradation of Materials in Nuclear Power Systems Water Reactors, TMS/ASM, pp.397-406 (1987). [3] EPRI: Recommendations for an Effective Flow-Accelerated Corrosion Program (NSAC-202L-R4), Technical Report, November (2013). [4] B. Poulson: Predicting and preventing flow accelerated corrosion in nuclear power plant, International Journal of Nuclear Energy, Vol. 2014, Article ID 423295 (2014). [5] L. Tomlinson, C.B. Ashmore: Erosion-corrosion of carbon and low alloy steels by water at 300, British Corrosion Journal., Vol.22, No. 1, pp.45-52 (1987). [6] J.O. Robinson, T. Drews: Resolving flow-accelerated corrosion problems in the industrial steam plant, Proc. CORROSION 99, Paper No.346 (1999). [7] R.B. Dooley: Flow-accelerated corrosion in fossil and combined cycle/hrsg plants, Power plant chemistry, 10(2), pp.68-89 (2008). [8] S. Nasrazadani, R.K. Nakka, D. Hopkins, J. Stevens: Characterization of oxide on FAC susceptible small-bore carbon steel piping of a power plant, International Journal of Pressure Vessels and Piping, 86, pp.845-852 (2009). [9] P.N. Blumberg, R.L. Curl: experimental and theoretical studies of dissolution roughness, Journal of Fluid Mechanics, vol.65, issue4, pp.735-751 (1974). [10] B. Villien, Y. Zheng, D.H. Lister: The scalloping phenomenon and its significance in flow-assisted-corrosion, Proceedings of the Twenty Sixth Annual CNS-CAN Student Conference, (2001). [11] N. Fujisawa, K. Uchiyama, T. Yamagata: Mass transfer characteristics of flow on periodic rough pipe and downstream of an orifice, Proceedings of the International Conference on Flow Accelerated Corrosion, (2016). [12] H. Abe, T. Yano, Y. Watanabe, M. Nakashima, T. Tatsuki: Characteristics of scalloped surface and its relation to FAC rate of carbon steel piping elbow, Transactions of the JSME (in Japanese), Vol. 83, No. 847 p.16-00453, (2017). [13] J.M. Pietralik: The Role of Flow in Flow-Accelerated Corrosion under Nuclear Power Plant Conditions, E-Journal of Advanced Maintenance Vol.4 No.2, pp.63-78 (2012). [14] G.J. Bignold, K. Garbett, R. Garnsey, I.S. Woolsey: Erosion-corrosion in nuclear steam generators, Proc. Second Meeting on Water Chemistry of Nuclear Reactors, British Nuclear Engineering Society, London, pp.5-18 (1980). [15] Nuclear and Industrial Safety Agency: The secondary system pipe rupture accident at the Mihama Power Station Unit 3 of Kansai Electric Power Co., Inc., Final Report (2005). 32