The Kodiak 3200 Seating System by Royal Stewart Ltd.:

Similar documents
SHERIDAN SEATING INC.

Bryan County Middle/High Renovation SECTION TELESCOPING STANDS

SHERIDAN SEATING INC.

SHERIDAN SEATING INC.

BID PACKAGE FOR MEZZANINE BLEACHER INSTALLATION AT INDIAN LAKE HIGH SCHOOL. Located at: 6210 SR 235 N. Lewistown, OH

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SPECIFICATION FOR PERMANENT BEAM GRANDSTAND WITH INTERLOCK WELDED DECK SYSTEM

SECTION ORCHESTRA PIT FILLER

City of Minot Auditorium Non-Upholstered Arena Seating Specifications

SECTION Permanent Grandstands PART 1 GENERAL 1.1 RELATED DOCUMENTS

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

Invitation to Bid BLEACHERS AT BHS

SECTION ROOF EDGE SAFETY RAILING SYSTEM

SECTION METAL ATHLETIC LOCKERS

***************************************************************************************************************

SPECIFICATION FOR CI DECKING SYSTEM

SECTION ORNAMENTAL WELDED STEEL FENCING

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

GENERAL SPECIFICATION FOR GI DECKING SYSTEM

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

Acclaim C1 Specifications Theatre Seating Page 1 of 1

1.02 SYSTEM DESCRIPTION

StageRight February Pioneer Parkway Clare, Michigan Toll Free Website

SECTION PORTABLE RAILING SYSTEM

Park Hill School District South HS Football Venue & Park Hill HS Soccer Venue

SECTION INCLINE WHEELCHAIR LIFT PART 1 GENERAL 1.1 SECTION INCLUDES. A. Stair wheel chair lift. 1.2 RELATED SECTIONS

SECTION VERTICAL WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

1.02 SYSTEM DESCRIPTION

SECTION METAL ATHLETIC LOCKERS

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION METAL STAIRS

Trex Commercial Products page Metal Railing

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

Stages and Risers. National Public SEATING Corp. Shown NPS Seated Risers

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

2. Division 16 Electrical sections for electrical wiring and connections for electrically operated Telescoping Platform Seats.

FABRICOIL BASIC January 10, 2006

SECTION PREFABRICATED SHOWER COMPARTMENTS

CANADIAN MANUFACTURED PALLET RACKING OUR STRENGTH IS OUR PRODUCT ROLLFORMED RACK

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

PUSH-BUTTON SERIES SELF-CLEANING LIP LUG DESIGN CLOSED BUMPER BLOCKS

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

WEC Manufacturing Phone: (901) Website: Itswec.com

Sport Systems Canada Inc. Section Angle Framed Bleachers Page 1

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

Section Permanent Beam Grandstands

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

RAOUL WALLENBERG HIGH SCHOOL SECURITY COILING GRILLE SFUSD PROJECT NO SAN FRANCISCO UNIFIED SCHOOL DISTRICT SECTION 08330

SECTION METAL STAIRS

SECTION ACCORDION FOLDING PARTITIONS

WALL CANTILEVER WORK STATION JIB CRANE

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

ADDENDUM NO. 5. April 9, 2014

SECTION ALTERNATING TREAD ALUMINUM STAIRS

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION Coiling Doors and Grilles Model 4320

Soundmaster & Modernfold TECHNICAL DATA

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

SECTION ROLLER GATES

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION)

Product Guide Specification

B. Related Sections include the following:

1. High bay shelving units, fabrication and installation including leveling.

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

SECTION METAL EQUIPMENT LOCKERS

SUGGESTED SPECIFICATION SECTION ENTRANCE FLOOR MATS AND FRAMES

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION ALUMINUM BLEACHER SYSTEM (NEW SCHOOLS/REPLACEMENT AT EXISTING SCHOOLS)

SECTION ORNAMENTAL ALUMINUM FENCING

S125 Specifications For HPL Covered Panels On Bolted Stringer System

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

SECTION STRUCTURE MOUNT RAILING SYSTEM

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION ORNAMENTAL ALUMINUM RAILING

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Aluminum Perforated Rolling Door

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

SECTION SECTIONAL OVERHEAD DOORS

Transcription:

The Kodiak 3200 Seating System by Royal Stewart Ltd.: PART 1 GENERAL 1.01 Summary A. Bleacher System shall be Series 3200 Platforms as manufactured by Royal Stewart Ltd., Winnipeg, Manitoba, in accordance with applicable codes, the following specifications, and approved drawings. B. Related Sections a. Division 16 Electrical sections for electrical wiring and connections for electrically operated telescoping Gym Seats. 1.02 References A. National Fire Protection Association (NFPA) a. NFPA 102 Standard for Assembly Seating, Tents and Membrane Structures B. American Welding society (AWS): a. AWS D1.1 Structural Welding Code Steel b. AWS D1.3 Structural Welding Code - Sheet Steel C. Americans with Disability Act (ADA) a. ADA - Standards for Accessible Design 1.03 Manufacturer s System Engineering Description A. Structural Performance: Engineer, fabricate and install telescopic gym seat to the following structural loads without exceeding allowable design working stresses of materials involved, including anchors and connection. Apply each load to produce maximum stress in each respective component of each gym seat unit. a. Design Loads: Comply with NFPA 102, 1992 Edition, Chapter 5 for design loads. B. Design Criteria: a. Bleachers shall be designed at minimum to withstand the following loads and forces in addition to their own weight: i. Seat and footboards shall be designed to withstand a vertical live load of 120 lbs. per lineal foot (178 kg /m) ii. Platforms shall be designed to withstand a vertical live load of 100 lbs. per square foot (488 kg/ sq.m) iii. Each row shall withstand a horizontal side sway force of 24 lbs. per lineal foot (37.5 kg / meter) iv. End and back rails shall withstand an outward force of 50 lbs. per lineal foot at the top rail (74.4 kg / m)

1.04 Submittals A. Shop Drawings: Indicate Telescoping Gym Seat assembly layout. Show seat heights, row spacing and rise, aisle widths and locations, assembly dimensions, anchorage to supporting structure, material types and finishes. a. Wiring Diagrams: Indicate electrical wiring and connections. b. Graphics Layout Drawings: Indicate pattern of contrasting or matching seat colors. B. Samples: Seat materials and color finish as selected by Architect from manufacturers standard color finishes. C. Warranty: Manufacturers standard warranty documents. 1.05 Quality Assurance 1.06 Warranty PART 2 PRODUCTS A. NFPA Standard: Comply with current NFPA 102 Standard for Assembly seating, Tents, and Membrane Structures, and specifically with Chapter 5 Folding and Telescopic Seating, except where additional requirements are indicated or imposed by authorities having jurisdiction. B. Welding Standards & Qualification: Comply with AWS D1.1 Structural Welding Code - Steel and AWS D1.3 Structural Welding Code - Sheet Steel. C. Installer Qualifications: Engage experienced Installer who has specialized in installation of telescoping gym types similar to types required for this project and who is acceptable to, or certified by, telescoping gym seat manufacturer. A. Standard manufacturer s Five (5) year limited warranty: The manufacturersupplied materials will be warranted against faulty materials and workmanship for a period of five (5) years. This guarantee excludes any parts determined to have been subject to accident, abuse, misuse or neglect. Contact Royal Stewart Ltd. for complete warranty documentation. 2.01 Manufacturers A. Manufacturer: Royal Stewart Ltd. a. Winnipeg, MB, Canada b. Telephone: (204) 224-3221 c. Website: http://www.royalstewart.com

2.02 Supply and Install A. Seating Area: Bank A - Long x Rows High Bank B - Long x Rows High Mounting: Wall Attached / Floor Attached / Portable / Recessed / Reverse Fold (For all other configurations, contact Royal Stewart Ltd.) Operation: Motorized B. Dimensions: a. Rise per row: 9-5/8 (245 mm) / 10 ¼ (260 mm) 11-5/8 (295 mm) / custom available) b. Row spacing: 30 (762 mm) / 32 (813 mm) / 33 (838 mm) / custom available) c. Closed dimension: d. Extended dimension: C. Accessories: (number accordingly) Aisles shall be footrest level wide, or as per code. Aisles at the footrest level shall have non-slip treads on the top front edge. End rails - Self-storing insta-rails shall be provided at the open ends of the group. All end rails must be designed to integrate with the decking and under structure. Rails shall meet all national codes. All rails shall be made from 1 (25 mm) OD cold rolled 14 gauge round. Non-removable folding aisle handrails shall be provided. Aisle railings shall be permanently attached to the mounting pocket and allow railings to pivot and fold sideways and down for storage. Aisle railing shall be an individual rail design, located on every other row starting at row two (2). Railings to be constructed of 1.5 (38 mm) round stainless steel tubing. Aisle rails that require removal are not acceptable. Provided One (1) Scorer s Table ADA truncations required as recommended by manufacturer and as per ADA Back Rails (for reverse fold or portable) Front Rails (if required) End Panels - to the 96 (2438 mm) level Back Panels (for reverse fold or portable) Rear Filler Board (at seat height) Backup motion monitor

2.03 Understructure Fabrication A. All bleacher wheels shall be a minimum 4 (102 mm) in diameter with 1 ¼ (32 mm) soft, non-marring face for floor protection. B. Each row shall be outfitted with a minimum of eight (8) of the above wheels. C. Bleacher uprights shall be made of square and rectangular tubing. All bleacher leg tubing to be minimum 1.5 (38 mm) x 3 (76 mm) rectangular hollow structural tube (MINIMUM 125 wall). Tubing will be manufactured to B.W.G. specifications using S.A. E. 1010 steel. Structural C formed steel is not acceptable. D. All wheel channels to be 11-gauge steel. E. All bleacher slide arms to be 7-gauge steel. F. All bracing to be angle iron. Flat bar or formed steel bracing is not acceptable. G. Travel distance of each row shall be determined by the steel horizontal members under each row (or deck) and also by the mechanical trip-locks at the bottom of each upright. All row-locks must be a minimum ¼ (6 mm) steel. H. Platform decks shall be manufactured using ¾ (19 mm) Panelam or painted plywood decking 5/8 (16 mm) decking is not acceptable. H. Deck shall be supported over full length by rear and front channel. In addition, front and back supports will be supplied as required. Rear and front channels shall be 14-gauge galvanized steel. J. Deck level rear filler up to 6 ½ (165 mm) included. K. All hardware shall be plated and stress rated. 2.04 Bleacher Finish A. All steel framing shall be finished Flat Black. B. Rear and front channels shall be 14 gauge galvanized. 2.05 Chair System A. VIP Chairs shall be provided a. VIP Plastic chair shall be double wall blow molded polypropylene. Provided in manufacturer s standard range of colors. b. VIP 3320 Fully upholstered chair shall have 2 (50 mm) padding on seat and back. Provide in manufacturer s standard range of colors. c. VIP 3320 Fully upholstered chair shall have 2 (50 mm) padding on seat and back. Provide in manufacturer s standard range of colors. B. Operation a. Semi-Automatic Foot pedal semi automatic lowering and spring assisted lifting of chairs up to 11 seats in tandem.

2.06 Electric Operation PART 3 EXECUTION A. Smart-Drive / Posi-drive Propulsion System a. The entire system shall open and close by the Smart-Drive system. All Motors to be 1/2 HP instant reversing automatic resent 120 / 208 / 240 VAC. All tractor frames to be made from 7-gauge steel. All axle shafts to be 1 steel. All wheels to be vulcanized rubber. All drive chains and sprockets to be #50. All speed reducers to be Helical Drive. All wheels in the system must be mounted free floating to the first row of the bleacher with Heavy-duty springs and grade 5 hardened steel throughbolts (for up to 15 rows). Systems 15 rows plus shall use Posi-Drive HD system with 2 only 1 (25 mm) steel motor mount rods with steel bar weight harnesses set over the tractors according to duty. Number of tractors and added weight to be determined by requirements based on number of rows and type of seating. b. Manufacturer shall provide all wiring from power source within the bleacher systems including pendant control. Power requirement to be determined by seating manufacturer depending on the number of power units required. Power source to terminate in surface mounted junction box above the floor. Electrical contractor shall perform all connections to the seating equipment at the junction box. 3.01 Examination A. Verification of Conditions: Verify area to receive telescoping gym seats is free of impediments interfering with installation and condition of installation substrates is acceptable to receive telescoping gym seats in accordance with telescoping gym seats manufacturer's recommendations. Do not commence installation until conditions are satisfactory. 3.02 Installation A. Manufacturer's Recommendations: Comply with telescoping gym seats manufacturer's recommendations for product installation requirements. B. General: Install telescoping gym seats in accordance with manufacturer's installation instructions and final shop drawings. Provide accessories, anchors, fasteners, inserts and other items for installation of telescoping gym seats and for permanent attachment to adjoining construction.

3.03 Adjustment and Cleaning A. Adjustment: After installation completion, lubricate, test and adjust each telescoping gym seats assembly to operate in compliance with manufacturer's operations manual. B. Cleaning: Clean installed telescoping gym seats on both exposed and semiexposed surfaces. Touch-up finishes to restore damage or soiled surfaces.