Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

Similar documents
Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Analysis of Monoclonal Antibody (mab) Using Agilent 1290 Infinity LC System Coupled to Agilent 6530 Accurate-Mass Quadrupole Time-of-Flight (Q-TOF)

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Cell Culture Optimization Using an Agilent Bio-Monolith Protein A Column and LC/MS

Characterize mab Charge Variants by Cation-Exchange Chromatography

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Separation of Native Monoclonal Antibodies and Identification of Charge Variants:

Protein Separation with ph Gradients Using Composite Buffer Systems Calculated by the Agilent Buffer Advisor Software

A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

Molecular Characterization of Biotherapeutics The Agilent 1260 Infi nity Multi-Detector Bio-SEC Solution with Advanced Light Scattering Detection

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Fast and High Resolution Analysis of Intact and Reduced Therapeutic Monoclonal Antibodies (mabs)

Profiling Glycosylation of Monoclonal Antibodies at Three Levels Using the Agilent 6545XT AdvanceBio LC/Q TOF

Developing Purification Strategies for the Agilent 1260 Infinity II Preparative LC/MSD System

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

Application Note. Authors. Abstract. Biopharmaceuticals

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Automated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Size Exclusion Chromatography/ Mass Spectrometry Analysis of Antibody Drug Conjugates Using the Agilent 1260 Infinity II Bio-Inert LC

Agilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis. WCBP Jan 2017 Washington, DC

Peptide Mapping: A Quality by Design (QbD) Approach

Reproducible LC/MS Peptide Separation Using Agilent AdvanceBio Peptide Plus Columns

Application Note. Abstract. Author. Biopharmaceutical

Minimizing Sample Carryover Using the Multiwash Function of the Agilent 1290 Infinity II Multisampler

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Method Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

Agilent 1290 Infinity Binary LC System with ISET Emulation of a Waters Alliance 2695 LC Applying Concave, Convex, and Linear Gradients

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

A Comprehensive Approach for Monoclonal Antibody N-linked Glycan Analysis from Sample Preparation to Data Analysis

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Automated QbD-Based Method Development and Validation of Oxidative Degraded Atorvastatin

Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody

Host Cell Protein Analysis Using Agilent AssayMAP Bravo and 6545XT AdvanceBio LC/Q-TOF

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore, India

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

AdvanceBio HIC: a Hydrophobic HPLC Column for Monoclonal Antibody (mab) Variant Analysis

Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1.

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Application Note. Author. Introduction. Ravindra Gudihal Agilent Technologies India Pvt Ltd

Fast Method Development Using the Agilent 1290 Infinity Quaternary LC System with Column Selection Valve

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma)

Monitoring of Mammalian Cell Culture Media with HILIC LC/MS

Ensure your Success with Agilent s Biopharma Workflows

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Agilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore India

Performance characteristics of the 1260 Infinity Quaternary LC system

Analysis of Monoclonal Antibody N-glycans by Fluorescence Detection and Robust Mass Selective Detection Using the Agilent LC/MSD XT

Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD)

Comparing gradient transfer of isocratic hold and delay volume addition using the Agilent 1290 Infinity LC with ISET

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

Agilent 1290 Infinity Quaternary LC Support of Columns with 2.1 to 4.6 mm ID to 1200 bar

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Intact & Subunit Purity

Mobile Phase Optimization in SEC Method Development

Application Note. Environmental. Agilent 1290 Infinity Binary LC. with ISET and fine-tuning. Agilent 1290 Infinity Binary LC.

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Agilent 1290 Infinity 2D-LC Solution. Selectable separation performance

High-Resolution Separation of Intact Monoclonal Antibody Isoforms

Application Note. Author. Abstract. Pharmaceuticals. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

MassPREP On-Line Desalting Cartridge

Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns

Application Note. Biopharma. Authors. Abstract. James Martosella, Phu Duong Agilent Technologies, Inc Centreville Rd Wilmington, DE 19808

Agilent 6400 Series Triple Quad LC/MS System

Monoclonal Antibody Analysis on a Reversed-Phase C4 Polymer Monolith Column

Faster Separations Using Agilent Weak Cation Exchange Columns

Monoclonal Antibody Charge Variants Identification by Fully Automated Capillary Isoelectric Focusing Mass Spectrometry

Application Note. Authors. Abstract. Introduction. Pharmaceutical

Identifying Monoclonal Antibody Mutation Sites Using the Agilent 1290 Infinity II 2D-LC Solution with Q-TOF LC/MS

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

The Agilent Metabolomics Dynamic MRM Database and Method

Transcription:

Clone Selection Using the Agilent 9 Infinity Online D-LC/MS Solution Application Note Biopharmaceuticals Authors Abstract Ravindra Gudihal and This Application Note describes the Agilent 9 Infinity online D-LC/MS Syed Salman Lateef solution and proof of principle for clone selection and quantification of monoclonal Agilent Technologies, India Pvt Ltd, antibody (mab) using an Agilent Bio-Monolith Protein A column in the first Bangalore, India dimension followed by a desalting step with an Agilent AdvancedBio RP-mAb diphenyl column in second dimension that is coupled to a mass spectrometer. The first step provides the enrichment of the mab, and the second step was used for confirmation of right quality of the mab. OUT 8 OUT 7 8 ²D-Column.. 8 8..8.... C.8.8.... 8 8,,8,,, E,,8,,, F.... 7,7.9 G. 7,9.9 7,.9.8. 7,88. 7,8.97.. 7, 7, 7, 7, 7,8 D.. B.8... ²D-Pump.8 8 ¹D-Column.. H..8... Waste. A.8...,,8,,, 7,.7 7,. 7,8. 7,9.7 7,899.7 7, 7, 7, 7, 7,8. I 8,.9. 8,. 8,8.7.8.. 8,7.9. 7,98. 7,8 8, 8, 8, 8, IN

Introduction Monoclonal antibodies (mabs) are the fastest growing protein therapeutics in recent years. There is also rapid growth of biosimilars on the market. During the development of mabs, a well-planned strategy for good clone selection, having the correct intended mab with a good amount of expression, is critical. This is also true for biosimilars development. Currently, clone selection involves enrichment or purification of the mab, and collection of the enriched fraction, followed by mass spectrometry analysis in a separate experiment. Online D-LC/MS analysis provides a solution to perform different analysis methods in one run. This Application Note describes a combination of protein enrichment and purification with affinity chromatography in the first dimension, followed by reversed-phase chromatography coupled to an accurate-mass spectrometer for protein mass confirmation in the second dimension. In this study and as proof of principle, we used a commercial innovator and biosimilar pair of rituximab spiked in Dulbecco s Modified Eagle Medium (DMEM) as a matrix mimic to demonstrate the online D-LC/MS methodology. This method can easily be applied during the clone selection process. Materials and Methods Rituximab biosimilar and innovator were purchased from a local pharmacy, and stored according to the manufacturer s instructions. Acetic acid, formic acid, sodium phosphate, monobasic, sodium phosphate dibasic, sodium chloride, and LC/MS grade solvents were purchased from Sigma-Aldrich. Fresh ultrapure water was obtained from a Milli-Q Integral system equipped with a. µm membrane point-of-use cartridge (Millipak). Sample preparation The antibodies stock solution present at mg/ml was diluted with DMEM medium for construction of a calibration curve. The samples were centrifuged at, g for minutes prior to the injection. Instrumentation The Agilent 9 Infinity D-LC solution was composed of the following modules: Agilent Infinity Bio-Inert Quaternary Pump (GA) Agilent 9 Infinity Binary Pump (GA) Agilent 9 Infinity Autosampler (GA) with 9 Infinity Thermostat (GB) Agilent 9 Infinity Thermostatted Column Compartments (x GC) Agilent 9 Infinity valve drive (G7A) with -position/-port duo-valve (D-LC valve head, GA) Agilent 9 Infinity valve drives (x G7A) with multiple heart cutting valves (x G ) equipped with -µl loops Agilent Infinity Diode Array Detectors (x GC) with -mm flow cell Agilent Accurate Mass Q-TOF LC/MS (GA) Columns D: Agilent Bio-Monolith Column Protein A,.. mm,. µm (p/n 9-9) D: Agilent AdvanceBio RP-mAb Diphenyl,. mm,. µm (p/n 79977-9) Software Agilent OpenLab CDS ChemStation Edition software, version C..7 [7] with Agilent 9 Infinity D LC Acquisition software, version A.. Agilent MassHunter Workstation for instrument control (B..) The data obtained from LC/MS were analyzed using Agilent MassHunter Qualitative Analysis software B.7 and Agilent MassHunter BioConfirm software B.7

Table. LC/MS instrument parameters. Parameter Valve and loop configuration D pump Value -pos/-port duo loops (countercurrent) loop size µl Agilent Infinity Bio-inert Quaternary Pump D mobile phase A) PBS (Sigma p/n P7) B). M acetic acid in water D column temperature C D gradient Injection volume µl Thermostat temperature C Diode array detector D pump D mobile phase D column temperature 8 C Time (min) %B Flow rate (ml/min)..... 8 nm, nm, Ref. nm, nm Peak width D >. minutes Peak width D >. minutes Agilent 9 Infinity Binary Pump A) 98 % water, % IPA,. % FA B) 7 % IPA, % acetonitrile, % water,. % FA D gradient Time (min) %B Flow rate (ml/min)... 7. 9.... Mode Agilent Q-TOF LC/MS System Ion mode Source Drying gas temperature C Drying gas flow HiRes sampling, cuts, time-based Positive ion mode Agilent Dual Jet Stream 8 L/min Sheath gas temperature C Sheath gas flow Nebulizer Capillary voltage Nozzle voltage L/min psi, V, V MS range (m/z),, LC flow diversion Time segment Start time (min) Diverter valve position Waste MS Waste

Results and Discussion The Protein A purification for the enrichment of mabs from the matrix medium was developed earlier. In this study, we adapted the method for the first dimension affinity purification of the mabs (Table ). Similarly, we adopted the reversed phase method developed earlier for the second-dimension chromatography involving the online desalting of mabs, which is coupled to a mass spectrometer. A newer shorter Agilent AdvanceBio Desalting RP Cartridge for second dimension is also available for faster analysis. Figure shows a plumbing diagram for multiple heart cutting with the central D-LC valve in a countercurrent configuration, and two multiple heart-cutting valves. The multiple heart-cutting setup consists of twelve µl loop in two -position/ port valves, which has excellent peak parking capabilities. The experiments were accomplished using this valve configuration. To set up the online D-LC/MS method for clone selection, a previously recorded first-dimension chromatogram of affinity purification was loaded using the preview option in the D pump setup. The peak from Protein A purification of mab was heart-cut for the seconddimension analysis, as shown in Figure. Figure shows the D pump setup with the Protein A purification of mab at the bottom. The D time segments of the Protein A purified peak, which were sampled using high-resolution heart cutting, is shown as the light orange bar on the chromatogram. Waste IN D-Column OUT 7 8 IN D-Column D-Pump Figure. Plumbing diagram for multiple heart-cutting with central D-LC valve in countercurrent configuration and two multiple heart-cutting valves. OUT Figure shows the D Heart-cut viewer, displaying the third cut position of the first-dimension chromatogram (A). It also shows the D UV trace as recorded by the diode array detector (DAD) for the cut portion in the bottom panel (D). The viewer also shows the sampling table with the marked third heart-cut (B) and a peak table (C).

Figure. Method setup for high resolution peak sampling. The preview shows the four high-resolution cuts of the Protein A peak stored in different loops. Figure. Results of the second-dimension analysis of Protein A. First-dimension chromatogram with marked heart cut (A), Sampling table (B), Peak table (C), and second-dimension chromatogram (D).

During the biosimilar development programs, low and high-producing clones need to be distinguished. To measure the absolute mab concentrations, an external calibration can be generated using the innovator molecule. In this study, the calibration curve was constructed using the innovator rituximab. The calibration curve (Figure ) and corresponding chromatograms (Figure B) of innovator rituximab is shown. Good linearity was achieved ranging from. to µg/µl. Two known spiked sample concentrations were determined using this calibration plot. The inset in Figure summarizes the results. The results suggest good recovery for the spiked sample, and shows the utility of such calibration curves for mab concentration determination in clones to distinguish between high-producing and low producing clones. Area, 8 mau A Protein A (D) Area = 99.977*Amt.8 Spiked sample (µg/µl) Recovery by d.8 µg/µl 98 %. µg/µl %.. 7. B µg/µl 7. µg/µl Correlation:.999 Amount (µg/µl). µg/µl... min Figure. Calibration curve for the rituximab spiked in DMEM using Protein A (A) and overlay of Agilent Bio-Monolith Protein A chromatograms of rituximab calibration points at 8 nm (B).

LC/MS analysis The second-dimension effluent was also introduced into the Agilent Accurate Mass Q-TOF LC/MS to determine the masses of mabs. Figure shows the LC/MS analysis of intact mabs. Good shapes with narrow peak width is achieved using IPA/ACN/H O mobile phase for an Agilent AdvanceBio RP-mAb Diphenyl column (Figures A, B, and C). Figures D, E, and F show the Gaussian distribution of the charge state envelope for the mabs. The deconvoluted spectra of the mabs (rituximab innovator and biosimilar and IgG) are shown in Figures G, H, and I. The spectra were deconvoluted using the peak modeling deconvolution algorithm in Agilent MassHunter BioConfirm software. Multiple mass peaks are observed, corresponding to different glycoforms attached to the mabs. The intact mab analysis reveals that the antibodies have differences in mass. The masses for the biosimilar and innovator pair for some major peaks are similar, but the biosimilar shows additional peaks that may correspond to additional modification in the biosimilar mab. An Application Note has been published showing charge heterogeneity in biosimilar mab describing possible charge variants,7. The IgG shows different molecular mass when compared with the biosimilar innovator pair. These results show the utility of accurate mass spectrometric analysis for distinguishing differences between mabs...8... A 8 8..8... D,,8,,,...8... G 7,8.97 7,7.9 7,9.9 7,.9 7,88. 7, 7, 7, 7, 7,8..8... B 8 8..8... E,,8,,,...8... H 7,.7 7,. 7,8. 7,9.7 7,899.7 7, 7, 7, 7, 7,8..8... C 8 8..8... F,,8,,,...8... I 7,98. 8,.9 8,. 8,8.7 8,7.9 7,8 8, 8, 8, 8, Figure. TIC of intact mabs (A, B, C), charge envelope (D, E, F), and their respective deconvoluted masses (G, H, I). A, D, and G is the biosimilar, B, E, and H is the innovator, and C, F, and I is IgG. 7

Mirror plots Mirror plots were used to compare the biosimilar-innovator pair. From the mirror plots, it can easily be seen that the biosimilar has more modifications compared to the innovator. These mirror plots help in making quick decisions about the quality of the clone to be selected for further studies. Conclusions An online D-LC/MS analytical method is demonstrated, consisting of multiple heart cutting with MS detection using affinity chromatography in the first dimension, followed by desalting using reversed-phase chromatography in the second dimension for clone selection. The Agilent 9 Infinity D LC solution with multiple heart cutting, together with the Agilent Accurate Mass Q-TOF LC/MS represents a perfect solution for clone selection during mab development. Agilent MassHunter BioConfirm software provided data extraction, deconvolution, and mirror plots for finding the differences between the mabs. This method can be useful during clone selection, and in the area of biosimilar comparison. References. Scott, A. M.; Wolchok, J. D.; Old, L. J. Antibody Therapy of Cancer, Nature Reviews Cancer,, 78 87.. Udpa, N.; Million, R. P. Monoclonal antibody biosimilars, Nature Reviews Drug Discovery,,. Counts...8... -. -. -. -.8 -. -. Biosimilar Innovator 7,8.97 7,8. 7,9.9 7,.7 7,7.9 7,. 7,.9 7,9.7 7,88. 7,899.7,8 7, 7, 7, 7, 7,8 8, 8, Figure. Mirror plots for biosimilar (light brown trace) and innovator (blue trace) comparing intact masses.. Dumont, E.; et al., Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS, publication number 99-EN,.. Suresh, Babu C. V., LC/MS of Intact Therapeutic Monoclonal Antibodies Using Agilent AdvanceBio RP-mAb, publication number 99-9EN,.. Suresh, Babu C. V., Gudihal, R. Agilent AdvanceBio Desalting-RP Cartridges for Online Desalting in D LC/MS mab Analysis, publication number 99-7EN,.. Schneider, S., D-LC/MS Characterization of Charge Variants Using Ion Exchange and Reversed-Phase Chromatography, publication number 99-7EN,. 7. Suresh Babu C. V., Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs, 99-7EN,. www.agilent.com/chem For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc., Published in the USA, September, 99-797EN