SUBMERSIBLE SEWAGE EJECTOR

Similar documents
SK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M.

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

SHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

SPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007

SD/SW/VS50 SD50 SW50 VS50

HPGR200 2 HP. Capacity-U.S. G.P.M.

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

VSS S U B M E R S I B L E S E W A G E P U M P S

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal

SECTION SUBMERSIBLE GRINDER PUMPS FOR WASTEWATER (LESS THAN 10 HORSEPOWER)

SECTION SLUDGE HOLDING TANK DECANTER PUMP

Series Sump and Sewage Systems

High Light. Motors are fully submersible Pumps can handle up to 2½ spherical solids (for 3 Discharge pumps only) Indoor and outdoor installation

Specifying Pumps Why Do Pumps Fail.

High Light. Motors are fully submersible Pumps can handle up to ½ spherical solids Indoor and outdoor installation Easy installation and removal

SPECIFYING PUMPS WHY DO PUMPS FAIL.

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING ENVIRONMENTAL, HEALTH & SAFETY

SECTION INFLUENT EQUALIZATION TANK PUMPS

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals.

B. Wiring Diagrams: For power, signal, and control wiring.

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

B. Pumps are to be manufactured by Flygt Pumps. No substitutes will be considered.

Rugged, reliable and efficient sump pumps... your assurance of a dry basement!

& ACCESSORIES WASTEWATERTER PUMPSUMPS -EFFLUENT PUMPS -SEWAGE PUMPS -GRINDER PUMPS -ENGINEERED GRINDERS -ENGINEERED NON-CLOGS -ACCESSORISS

SECTION PACKAGE BOOSTER PUMP STATIONS

SUGGESTED SPECIFICATIONS

Submersible Axial Flow Propeller Pumps

SUBMERSIBLE PUMPS FOR WASTEWATER (S-114)

DSC/DSCA3. EBARA Submersible Sewage Pumps Contents. Project: Model: Chk d: Date: Model

The following shall be incorporated into the Contract Documents dated 8 August 2018

SUGGESTED SPECIFICATIONS

JDL Submersible Grinder Pumps TABLE OF CONTENTS Project: Model: Chk d: Date:

Replacement Wastewater Disposal System Permit Application

Index - Section 40M Medium Sump / Drainage Pumps Bulletins 4508

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS

SUGGESTED SPECIFICATIONS Pump Frames through 64132

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Wilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps. Engineering Specification

SEWAGE GRINDER PUMPS AND PACKAGES

SERIES 800 Quality Design Features Assure Long, Trouble-Free Service

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT

SECTION SUBMERSIBLE END SUCTION PUMP

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

SINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804

MODEL 16ASX T/S - SPECIFICATION

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

t y p e V S A S E W A G E P U M P

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

PUMPS AND ACCESSORIES. Residential Fixtures Bathing Commercial Fixtures Faucets Accessories

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

Project: Model: Chk d: Date: Model 32DGUII61.5S

Complete Grinder Package Offering

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

T Series. Self-Priming Centrifugal Pumps

Submersible. Issue 2 / De-watering and Drainage, Sewage, Industrial and Agriculture. We have submersible pumps for every application.

Max Head ' 1/ ' 115 1" FNPT 10' Manual On/Off Little Giant (5-MSPR) '

Piranha Agitator Slurry Pumps.75 hp to 75 hp

Stainless Steel with Poly Amide Fiber Reinforced Resin make NORUS pumps Lightweight with Exceptional Durability.

INSTALLATION INSTRUCTIONS

INVITATION FOR BID. April , Purchase Two Submersible Non-clog Pumps. Purchasing Depanment 4725A Moffett Road

YEOMANS SUBMERSIBLE SOLIDS-HANDLING WASTEWATER PUMPS YEOMANS

MODELS PH PH PH

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

Simplex Fiberglass Lift Station: Hard Piped

Goulds Two Stage, Horizontally Split Case Pump

SECTION 5 SUMP & SEWAGE

**** SPECIFICATIONS ****

DIVISION 15- MECHANICAL Section Fire Pumps

Sump. Sewage. Effluent. Premium SSE Pumps. An Advantage You Can Count On

AN INTRODUCTION TO BRIILLER ENINGINEERING PRIVATE LIMITED, BENGALURU

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

Section MECHANICAL EQUIPMENT. A. General: applicable provisions of the contract drawings and general conditions govern work.

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

C o l u m n S u m p P u m p s

SITHE SUBMERSIBLE CHOPPER PUMPS BY BARNES. Excellence in Innovation.

SITHE SUBMERSIBLE CHOPPER PUMPS BY BARNES. Excellence in Innovation.

TM Series Induced Draft Cooling Tower Specifications

SECTION VI Duplex Lift Station with Above Grade Valve Pit

Pioneer Forced Draft Cooling Tower Specifications

RAOUL WALLENBERG HIGH SCHOOL SECURITY COILING GRILLE SFUSD PROJECT NO SAN FRANCISCO UNIFIED SCHOOL DISTRICT SECTION 08330

University of Delaware

SECTION HVAC PUMPS. A. Provide centrifugal HVAC pumps, called for in drawing schedule, and as needed for a complete and proper installation.

SPECIAL SPECIFICATION. Automatic Pump Station

MODEL INSTALLATION INSTRUCTIONS

Transcription:

PERFORMANCE DATA Wholesale Products Page: 6270-1 RPM: 1750 Discharge: 2 Solids: 2 12 40 HEAD-METERS 9 6 3 TOTAL HEAD IN FEET 30 20 10 SK60 0 0 Capacity-U.S. G.P.M. 0 20 40 60 80 100 120 Liters/Second 0 2 4 6 8 The curves reflect maximum performance characteristics without exceeding full load (Nameplate) horsepower. All pumps have a service factor of 1.2. Operation is recommended in the bounded area with operational point within the curve limit. Performance curves are based on actual tests with clear water at 70 F. and 1280 feet site elevation. Conditions of Service: GPM: TDH:

DIMENSIONAL DATA Wholesale Products Page: 6270-2 4-5/16" (109) 5-7/8" (149) 8-1/16" (128) 4-3/4" (120) 2" NPT DISCHARGE 3-13/16" (96) 11-1/2" (292) PUMP ON 11-7/16" (290) DISCHARGE HEIGHT 12-5/16" (312) 5-1/2" (139) PUMP OFF 6-9/16" (166) All dimensions in inches. Metric for international use. Component dimensions may vary ± 1/8 inch. Dimensional data not for construction purpose unless certified. Dimensions and weights are approximate. On/Off level adjustable. We reserve the right to make revisions to our product (s) and the product (s) specifications without notice.

ELECTRICAL DATA Wholesale Products Page: 6270-3 MODEL: R.P.M. 1750 MOTOR TYPE OIL FILLED WITH AUTOMATIC RESET THERMAL OVERLOAD GENERAL INSULATION CLASS A MOTOR PROTECTION AUTOMATIC RESET / THERMAL OVERLOAD HP VOLTAGE PHASE NEC CODE SERVICE FACTOR FULL LOAD AMPS 115 12 1/2 1-1 230 6

TECHNICAL DATA Wholesale Products Page: 6270-4 MODEL: Physical Data DISCHARGE SIZE SOLIDS SIZE 2 IMPELLER TYPE CABLE LENGTH PAINT 2 NPT (STANDARD), 3 NPT (OPTIONAL) NON CLOG 10 STANDARD 20 OPTIONAL PAINTED AFTER ASSEMBLY, DARK GREEN, WATER REDUCIBLE ENAMEL, ONE COAT, AIR DRIED. Temperature MAXIMUM LIQUID 140 F MAXIMUM STATOR - OIL FLASH POINT - Technical Data POWER CORD TYPE MOTOR HOUSING CASING IMPELLER MOTOR SHAFT HARDWARE O RINGS MATERIALS OF CONSTRUCTION MECHANICAL SEALS Standard: UPPER BEARING LOWER BEARING SJTW CAST IRON CAST IRON CAST IRON STEEL STAINLESS STEEL BUNA-N CARBON / CERAMIC SINGLE ROW-BALL SINGLE ROW-BALL

SPECIFICATION DATA Wholesale Products Page: 6270-5 MODEL: 1.01 GENERAL Contractor shall furnish all labor, materials, equipment and incidentals required to provide (Qty.) submersible centrifugal sewage ejector pump(s) as specified herein. The pump model covered in this specification is the. The pump furnished for this application shall be MODEL as manufactured by Hydromatic Pumps. 2.01 DESIGN CONDITIONS Each pump shall be rated H.P., volts, phase, hertz and operate at RPM. 3.01 OPERATING CONDITIONS The pump shall deliver U.S. GPM/LPS at feet/meters TDH, and handle a inch solid. The curve submitted for approval shall state, in addition to head and capacity performance, solid handling capability, amp rating, and design impeller diameter. 4.01 CONSTRUCTION Each pump shall be of the sealed submersible type, incorporating features normally found in pumps furnished for the residential market. These features include: 1. The pump volute, motor, and seal housing shall be high quality gray cast iron, ASTM A-48, Class 30. 2. The pump inlet shall be open and clear, without screening to provide access for sewage and solids. 3. All external mating parts shall be machined and Buna N, O-Ring sealed. 4. All fasteners exposed to the pumped liquid shall be 300 series stainless steel. 5. All power cords shall be water resistant UL or CSA approved, with double insulation, and sized as a function of Amp. draw. 5.01 MOTOR AND SHAFT The stator, rotor and bearings shall be mounted in a sealed submersible type housing. Single phase motors shall be split phase or capacitor start with centrifugal switch. Three phase motors shall be Polyphase. Full Load and Locked Rotor Amps as well as Start and Run winding resistance shall be tabulated for each pump. 6.01 BEARINGS, SHAFT AND MECHANICAL SEAL An upper bushing bearing and lower thrust bearing shall be required. The upper bearing shall be brass while the lower bearing is a heavy duty single row ball. They are both permanently and continuously lubricated and cooled by the dielectric oil which fills the motor housing. The motor shaft shall be stainless steel and sealed from the pumped liquid with a carbon ceramic mechanical seal.

SPECIFICATION DATA Wholesale Products Page: 6270-6 7.01 IMPELLER The Impeller shall be high capacity, two vane, non-clog design with pump out vanes on the back side. These vanes wash out grit and stringy material that will damage the shaft and mechanical seal. 8.01 AUTOMATIC CONTROL All single phase pumps should be capable of automatic operation. 9.01 FLOAT SWITCH The pump is supplied with a tilt-sensitive wide-angle float switch which is sealed in a non-corrosive PVC enclosure. The unit is UL listed for water and sewage and CSA certified. The float switch shall also be fitted with a piggy-back plug that allows the pump to be operated manually without removal from the sump. 10.01 PAINTING All cast iron parts shall be painted before assembly with a water reducible alkyd air dried enamel. The paint shall be applied in one coat with a minimum thickness of 3 to 4 mils. 11.01 TESTING All pumps shall be individually tested to include the following: 1. The pump and power cord shall be visually inspected for imperfections, cuts or nicks. 2. The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for moisture content and/or insulation defects. 3. The motor and volute housing shall be pressurized and a 10 second air leak decay test run. 4. Oil is added, and the pump is run. Voltage and current are monitored visually, electronically, and the tester listens for any noise or malfunction. USA CANADA 293 Wright Street, Delavan, WI 53115 WWW.HYDROMATIC.COM 269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5 PH: 888-957-8677 ORDERS FAX: 800-426-9446 PH: 519-896-2163 ORDERS FAX: 519-896-6337 Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. 2013 Pentair Ltd. All Rights Reserved. W-01-260 (03/25/13)