Demountable suspended grid ceiling system

Similar documents
Demountable suspended grid ceiling system

A corridor ceiling system that combines acoustics, aesthetics and accessibility

Gyproc Lay-in Grid Ceilings

CasoLine GRID. Suspended grid ceiling system. The Manchester Academy

Gyptone GRID Suspended grid ceiling system

CasoLine MF Concealed grid MF suspended ceiling system

C09. S02. P02 P14 CasoLine mf

CasoLine mf. Concealed monolithic metal frame suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system

Independent twin frame high performance acoustic separating wall system

Staggered stud acoustic partition system

Loadbearing timber joist floors

The extra strong, extra durable, sound resistant system that you can direct fix to

Cavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings

C06. S05. P02 P12 GypFloor silent

C06. S05. P02 P12 GypFloor silent

CO9. Sound absorbing solutions C09

C06. S02. P02 P22 CasoLine mf

Curved partition and wall lining system

Issue date: 15th January Key changes since original publication (July 2005):

Selecting floors and ceilings

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

Single frame acoustic separating wall system

C06. S06. P02 P20 Loadbearing timber joist floors

C05. S03. P02 P08 FireWall

C05. S03. P02 P08 FireWall

GypWall RAPID db Plus

The ultimate sound insulating wall system

GypWall QUIET Acoustic separating wall system

FireWall. High performance fire-resistant wall system. FireWall.

GypWall TM EXTREME. GypWall EXTREME 4.5. Ultimate impact and abrasion resistant partition system. Key facts. Sector Guide

CO5. Specialist partitions C05. Introduction - ShaftWall 29/03/2018 FireWall 29/03/2018 GypWall curve 16/12/2016 GypWall secure 29/03/2018 BlastWall -

C05. S02. P02 P30 ShaftWall

May 2012 C1/SfB (35) R17. Gyptone Access Hatch Trap Guide. Rapid access system for corridor above-ceiling services

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide

Acoustic ceilings. Creating perfect living spaces. Technical Advice Centre Tel:

GypLyner UNIVERSAL Concealed grid ceiling lining system

GypLyner UNIVERSAL (Ceilings)

GypLyner UNIVERSAL Concealed grid ceiling lining system

GypLyner (Ceilings) Concealed grid ceiling lining system. GypLyner UNIVERSAL.

Staggered stud acoustic partition system

GypLyner IWL Independent wall lining system

Tiling Tiling Finishes C08

GypWall QUIET Acoustic separating wall system

EDGE D2 CONNECT GRID. Design and technique. Installation manual. Load. Product description. Stability. Plenum height. Weight.

ShaftWall. Shaft and duct encasement system. ShaftWall.

Knauf C-Form Suspended Ceilings

GypLyner UNIVERSAL Metal framed wall lining system

C04. S05. P02 P14 GypWall quiet sf

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

GypLyner UNIVERSAL Metal framed wall lining system

FlameLyner Industrial fire-resistant lining system

GypWall AUDIO The ultimate cinema wall system

Issue date: 1st May Key changes since original publication (July 2005):

Communal 51 Ceiling Systems by Vogl

Technical performance and principles of system design

GypWall AUDIO The ultimate sound insulating wall system

March CI/SfB (35) Rf7 Sf7. THE WHITE BOOK Product Range series. Ceiling Products. The creative solution for modern performance ceilings

C04. S11. P02 P13 Non-loadbearing timber stud

Knauf MF Suspended Ceilings

The ultimate impact resistant partition

Gyptone edge D1 system Installation manual

6.8. Semi-exposed soffits Semi-exposed Soffits. Key facts. Sector Guide. MultiBoard with thermally efficient phenolic foam

ShaftWall. Shaft and duct encasement system. ShaftWall.

C08. S04. P02 P08 Tiling

SoffitLine. Thermal lining system for semi-exposed soffits. SoffitLine.

GypFloor SILENT 6.4. Sound insulating floor system. Key facts. Sector Guide

Semi-exposed soffits. Thermal lining system for semi-exposed soffits. Semi-exposed soffits.

ting Join Jointing Finishes C08

ULTIMA Vector SAHARA Vector

CEILING SYSTEMS ORCAL AXAL VECTOR. Technical Data Sheet. Semi-concealed system on exposed 24mm grid. [ Between us, ideas become reality.

Single frame acoustic separating wall system

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Gypframe profiles. Dimensional specifications

Quantity take-off details

SECTION NON-STRUCTURAL METAL FRAMING

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

GypLyner (walls) Metal framed wall lining system. GypLyner.

June Non - Residential New Build Partition walls

Ceilings - Products. Arteco ceiling products. The creative solution for modern performance ceilings

Plaster skimming. Plaster skimming to plasterboard is a popular method of providing a smooth, seamless surface ready to receive decorative treatment

Tiling. Capital Gate Hotel, Abu Dhabi - UAE

Gypframe profiles. Dimensional specifications

Gypframe profiles. Dimensional specifications

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements

Construction Standards PAGE

SECTION ACOUSTICAL CEILINGS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

CEILING SYSTEMS ORCAL AXAL VECTOR. Semi-concealed system on exposed 24mm grid. Technical Data Sheet. [ Between us, ideas become reality.

Perforated Plasterboard

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

SIDERISE CBX flexible acoustic barriers for suspended ceilings

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

LINEAR METAL CEILINGS Section

System S 14a Linear rilled planks, concealed. System S 14b Linear rilled planks, semi-concealed. OWAcoustic premium. OWAconstruct

C08. S02. P02 P08 Plaster skimming

ROCKFON SYSTEM T24 A/E

Transcription:

C06 Floors and ceilings CasoLine quicklock grid t24 CasoLine quicklock grid t24 Demountable suspended grid ceiling system ll our systems are covered by SpecSure when using genuine Gyproc and Isover products

CasoLine quicklock grid t24 CasoLine quicklock grid t24 is a lightweight, exposed grid demountable ceiling system with a wide 24mm flange. It is compatible with a wide range of square edge and tegular layin ceiling tiles, including all Gyproc Gyprex and Gyptone tiles. Key benefits Gyprex tiles provide 30 minutes fire protection to steel beams supporting concrete floors firm and flush finish of the grid is achieved through the use of square, buttcut joints Easy installation due to simple hookon connections between grid and soffit cleat and as soon as one crosstee is in place, the grid is stabilised Hasslefree access to the ceiling cavity as a result of tees which are simple to remove, relocate and replace Highly flexible solution that accommodates all Gyproc ceiling tiles within the robust and stable CasoLine quicklock grid system Fully warranted system when both Gyproc tiles and CasoLine quicklock grid are used 30 mins 0.40.0 α w 37 39 D n,c,w db Refer to C0. S0. P08 CasoLine quicklock grid t24 Floors and ceilings C06 ROI: 800 744480 NI: 0845 399059 tech.ie@saintgobain.com C06. S04. P385

C06 Floors and ceilings CasoLine quicklock grid t24 CasoLine quicklock grid t24 performance Table Sound absorption bsorption class Table 2 Sound insulation Ceiling product Tiles Sound absorption coefficient α w Noise Reduction Coefficient (NRC) Gyprex satinspar 37 Gyprex bio 37 Gyptone base 3 37 Gyptone line 4 Gyptone quattro 20 Gyptone quattro 22 Gyptone point Gyptone point 2 Product D n,c,w db no insulation D n,c,w db 00mm Isover Spacesaver Plus ctiv ir technology as standard Plenum depth mm Insulation type System reference Tiles B 0.80 0.75 Gyptone quattro 20 300 75mm Isover coustic Batt C048 C 0.75 0.70 Gyptone point 300 75mm Isover coustic Batt C050 C 0.70 0.70 Gyptone line 4 300 75mm Isover coustic Batt C05 C 0.65 0.60 Gyptone line 4 200 C0004 C 0.65 (L) 0.65 Gyptone point 200 C0005 C 0.65 0.60 Gyptone quattro 20 200 C0003 C 0.60 0.75 Gyptone line 4 00 50mm Isover coustic Roll C0094 C 0.60 0.60 Gyptone point 00 C0093 D 0.50 (H) 0.50 Gyptone quattro 20 00 C0003 D 0.45 (L) 0.50 Gyptone quattro 22 200 C0007 D 0.40 (LM) 0.55 Gyptone point 2 200 C0006 For further assistance in choosing the right solution for your project, try our System Selector; an online tool that enables quick and easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to gyproc.ie These systems are supplied with ctiv ir as standard, which improves indoor air quality. System reference C0020 C002 C0008 39 C0004 39 C0003 39 C0007 39 C0005 39 C0006 For further assistance in choosing the right solution for your project, try our System Selector; an online tool that enables quick and easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to gyproc.ie Figures quoted for sound insulation refer to roomtoroom tests to BS EN 20409. Where higher levels are required other design considerations can be adopted, such as extending partitions into the ceiling void or installing a plenum barrier. C06. S04. P386 gyproc.ie

CasoLine quicklock grid t24 performance (continued) Table 3 Light reflectance Ceiling product Paint reference Light reflectance % Gyptone base 3 NCS 0500 82 Gyptone point NCS 0500 75 Gyptone point 2 NCS 0500 75 Gyptone quattro 20 NCS 0500 7075 Gyptone quattro 22 NCS 0500 7075 Gyptone line 4 NCS 0500 70 Gyprex satinspar 88 Gyprex bio 84 Light reflectance test conducted in accordance with STME 47798. Fire protection to steel beams supporting concrete floors Table 4 Solutions to satisfy the requirements of BS 476: Part 23: 987 2 For details of when to specify fire resistance using BS Refer to C02. S0. P05 CasoLine quicklock grid t24 Floors and ceilings E24 C06 Detail Tile type Edge Thickness mm Dimensions mm pprox. weight kg/m 2 Clips required System reference 30 minutes fire resistance Gyprex satinspar 8 600 x 600 6.9 yes C306006 For further assistance in choosing the right solution for your project, try our System Selector; an online tool that enables quick and easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to gyproc.ie Concrete floors as described in BS 476: Part 23: 987. The steel beams subjected to test had a section factor /V (Hp/) of 205m calculated on the basis of three sided profiled exposure. The suspended ceiling system will also provide the same fire protection to steel beams of a lower section factor. ROI: 800 744480 NI: 0845 399059 tech.ie@saintgobain.com C06. S04. P387

C06 Floors and ceilings CasoLine quicklock grid t24 CasoLine quicklock grid t24 design Building design CasoLine quicklock grid t24 is 24mm wide metal frame grid comprising CasoLine quicklock grid 24/38 Mains Tees, 24/38 Cross Tees and Wall ngles into which Gyptone or Gyprex tiles can be installed. Planning key factors Ceilings should be set out from the centre to give balanced widths of tiles at the perimeter. Two grid layouts are possible, depending upon the choice of ceiling tile. Refer to construction detail for configuration options. Designers and installers should take due regard of BS EN 3964: 204, Suspended Ceiling Requirements and test methods. Relative humidity (RH) The grid is suitable for use in heated occupied buildings in conditions up to 90% relative humidity (RH90). Gyprex tiles are suitable up to RH90 and Gyptone tiles up to RH70. Cavity fire barriers Where cavity fire barriers are required, they can be formed using Gyproc FireLine or Glasroc F multiboard screwfixed to a simple frame. The framing should be fixed to the structure to avoid undue loading of the ceiling suspension grid. The bottom of the framework should be fixed to the ceiling grid. Refer to C06. S09. P447 Cavity fire barriers. Firestopping It is necessary to provide suitable noncombustible firestopping material at the junction of a cavity fire barrier with the structural perimeter and the ceiling. Firestopping must also be provided around any service penetrations through the cavity fire barrier. Water vapour control Gyprex tiles have a water vapour resistance factor of 600. Whilst the vinyl surface can provide an effective vapour control layer, it may be necessary to complete the integrity where the boards abut metal grid sections. This is achieved by sealing with continuous beads of water vapour resistant sealant, which should be applied to the back of the metal sections prior to inserting the tiles. Care should be taken to ensure that the sealant does not damage the vinyl surface of the tiles. Other precautions, such as cavity ventilation, may be necessary to reduce the risk of interstitial condensation. Fixtures Gyptone base and Gyprex Gyptone base and Gyprex will support a point load of up to 3kg / tile for maximum 2mm deflection. This will normally allow items such as spotlights and downlighters to be installed without the need for a support pattress. support pattress should, however, be installed where the prevailing environmental conditions exceed 25 C and RH70, or where the size of the cutout required is greater than 50mm diameter or 50mm square. pertures for spotlights and downlighters can be cut into these ceiling tiles using a circular tank cutter on a power drill or using a pad saw. Gyptone perforated Gyptone perforated tiles should not be used to support fixtures, however this can be accommodated with the use of a pattress as described above. Services The ceiling void above the suspension grid can be used to route all service requirements including ducting, pipework, electrical cables, and conduits. Ducting, ventilation units, etc, must be independently supported from the structure. Maintenance Ceiling tiles can be cleaned using a damp cloth or soft brush. Most standard mild detergents can be used. Tiles other than Gyprex can be redecorated if required using a suitable emulsion paint and a shorthaired brush or roller (spray painting will impair sound absorption). Gyptone tiles with ctiv ir Though we don t notice them, impurities, such as Volatile Organic Compounds (VOCs) including formaldehyde, are often present in the air we breathe emitted from furniture, carpets and building materials. Longterm exposure to these can potentially cause health problems and reduce general wellbeing. Studies have shown that clean air, can speed up patient recovery in hospitals, reduce absence at work, and increase pupils concentration at school. ctiv ir is our latest technology designed specifically to convert formaldehyde emissions into nonharmful inert compounds. Tests show that ctiv ir decomposes 70% of the formaldehyde in a controlled test environment. This clever technology continues to work for over 50 years, and whilst alternative solutions absorb formaldehyde, they don t decompose them like ctiv ir, risking reemission at a later date. Refer to C02. S0. P62 Table 5 Selfweight of tiles in CasoLine quicklock grid t24 24mm grid systems Edge detail Selfweight of tiles kg/m 3 Gyptone 7.09.0 Gyprex 6.3 SpecSure ll our systems are covered by SpecSure when using genuine Gyproc and Isover products. C06. S04. P388 gyproc.ie

CasoLine quicklock grid t24 construction details Edge Square Edge E24 Rebated 6 5 4 2 3 7 CasoLine quicklock grid t24 Floors and ceilings x x 4 4 C06 7 7 3 2 2 5 and 6 5 and 6 Layout Tiles 600mm x 600mm (standard stock) Main Tee at 200mm centres Hangers at 200mm centres Layout 2 Tiles 200mm x 600mm (special order, subject to leadtime) Main Tee at 200mm centres Hangers at 200mm centres T24 exposed grid system for tiles with square edge () and tegular edge E24 CasoLine quicklock grid 24/38 Main Tee 2 CasoLine quicklock grid 24/38 Cross Tee 200mm 3 CasoLine quicklock grid 24/38 Cross Tee 600mm 4 CasoLine quicklock grid W02 Wall ngle / CasoLine quicklock grid W03 Wall ngle (suitably fixed at 300mm centres) 5 CasoLine quicklock grid Hanger 6 Gypframe MF2 Soffit Cleat 7 Gyptone or Gyprex tile ROI: 800 744480 NI: 0845 399059 tech.ie@saintgobain.com C06. S04. P389

C06 Floors and ceilings CasoLine quicklock grid t24 CasoLine quicklock grid t24 components Ceiling products CasoLine quicklock grid 24/38 Main Tee Main tee for construction of CasoLine quicklock grid t24 and d. CasoLine quicklock grid 24/38 Cross Tee Cross tee for construction of CasoLine quicklock grid t24. CasoLine quicklock grid Hangers Highstrength adjustable hangers for suspension of CasoLine quicklock grid. CasoLine quicklock grid t24. PNCLIP96 Hold down clip used with Gyprex satinspar in fire rated situations. ctiv ir technology as standard. Gypframe metal components Gypframe MF2 Soffit Cleat Suspension point, one leg connected to structural soffit and the other leg connected to suspension wire/hanger. CasoLine quicklock grid W02 Wall ngle 9mm x 24mm wall angle for construction of a perimeter of a CasoLine quicklock grid. CasoLine quicklock grid W03 Wall ngle 24mm x 24mm wall angle for construction of a perimeter of a CasoLine quicklock grid. vailable in: range of Gyprex and Gyptone tiles are compatible with CasoLine quicklock grid t24. E24 CasoLine quicklock grid 24mm Tee sections. Metal products (by others) Suspension wire Metal wire to provide support for suspended ceiling systems. Insulation products Isover coustic Roll Glass mineral wool for enhanced acoustic and thermal performance. Isover coustic Batt Glass mineral wool for enhanced acoustic performance. Isover Spacesaver Plus Glass mineral wool for enhanced acoustic and thermal performance. C06. S04. P390 gyproc.ie

CasoLine quicklock grid t24 installation overview This is intended to be a basic description of how the system is built. For detailed installation guidance refer to the Gyproc Installation Guide. Measure and mark the required ceiling Mark the position required for the height, then fix the CasoLine quicklock suspension points and fasten the grid W02 Wall ngle or W03 Wall ngle CasoLine MF2 Soffit Cleats to soffit. around the perimeter of the ceiling area to suit. Use CasoLine quicklock grid Hangers to suspend the CasoLine quicklock grid 24/38 Main Tee. CasoLine quicklock grid t24 Floors and ceilings Install 600mm and/or 200mm CasoLine quicklock grid 24/38 Cross Tee as required. CasoLine quicklock grid is selfsquaring, so with the CasoLine quicklock grid 24/38 Cross Tee in place to form the grid, tiles can be easily laid into place. C06 If you are installing a fire rated system, using Gyprex satinspar, install PNCLIP96. dditional information For full installation details, refer to the Gyproc Installation Guide, available to download from gyproc.ie ROI: 800 744480 NI: 0845 399059 tech.ie@saintgobain.com C06. S04. P39