Installation guide. ROCKFON System Z mm. 600 mm

CI/SfB. October RockLink 15. Installation system

CI/SfB. June RockLink 24 Monolith. Installation system

TIME SAVING AND HASSLE FREE CORNER CAPS LIGHT FRAME PAIRS SERVICE INTEGRATION WITH BEAUTIFUL DESIGN OUR HOLD DOWN CLIPS SECURE YOUR MODULAR CEILINGS

Installation guide System X

Rockfon System Eclipse Wall

Rockfon Concealed Acoustical Ceiling Systems (CDX and SCD)

Rockfon Concealed Acoustical Ceiling Systems (CDX and SCD)

ROCKFON SYSTEMS. MONOLITHIC CEILINGS: ROCKFON System Mono Acoustic

EDGE D2 CONNECT GRID. Design and technique. Installation manual. Load. Product description. Stability. Plenum height. Weight.

SECTION COMPOSITE CORE ACOUSTICAL PANEL CEILINGS. Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3

Ecophon Focus Lp. Size, mm 600x x x x x x x600 T24 Thickness (THK) M390, M391 M390, M391

System S 14a Linear rilled planks, concealed. System S 14b Linear rilled planks, semi-concealed. OWAcoustic premium. OWAconstruct

System F - Free Span Systems

Rockfon Concealed Acoustical Ceiling Systems (CDX) for Seismic Category D, E, F Applications

General applications. Fast. Easy. Customer Focused.

system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0)

Ecophon Focus Ds. System range. Size, mm 600x x x x x x x600 T24 Thickness (THK)

Basic Suspension Systems

Gyptone GRID Suspended grid ceiling system

Ecophon Advantage A. and accessories. The Connect grid is manufactured from galvanized steel.

QUICK-LOCK QUICK-LOCK. A complete survey of all Quick-Lock ceiling systems. QUICK-LOCK Ceiling systems. QUICK-LOCK Cross-Lock.

Ecophon Advantage E. covered with glass tissue. The edges are painted.

Ecophon Focus Dg. System range. Size, mm T24. Thickness Inst. Diagr. Kia Motors, Breukelen, Netherlands. Ecophon Ecophon Focus Dg, Created:

system 150 modular hinge-down clip-in tiles (concealed grid) SAS International +44 (0)

Ecophon Gedina A. Size, mm 600x x x1200 T15 T24 Thickness (THK) Inst. Diagr. M237

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION NON-STRUCTURAL METAL FRAMING

System S 9a/b Concealed, demountable

Ecophon Focus Ds TECH

technicalnote Seismic Category D, E, F Installation Details Fully Concealed Rockfon CDX FIELD INSTALLATION Grid

Gyptone edge D1 system Installation manual

EXPOSED GRID CEILING SYSTEMS INSTALLATION GUIDE

Ecophon Gedina A. Size, mm 600x x x1200 T15 T24 Thickness (THK) Inst. Diagr. M237

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

METALWORKS RH215 Faceted Custom Hook-on Panels

GRID SYSTEM ECOPLUS SYSTEMS TWO-WAY EXPOSED SUSPENDED CEILING GRID SYSTEM

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

UniSpec II - Store Planning

SECTION GYPSUM BOARD ASSEMBLIES

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

SECTION LINEAR METAL CEILINGS

Ecophon Focus Dg. System range. XL 1200x x x600. Size, mm. XL 1800x600. XL 2000x x600 T24 Thickness Inst. Diagr.

STANDARD PRODUCTS - CUSTOM LOOK

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

System S 9a / S 9b. demountable. OWAlifetime collection

Ecophon Gedina E. System range. Size, mm 600x x x1200 T15 T24 Thickness (THK) M121, M270, M401 M121, M401. Inst. Diagr.

unity 6 system / Demountable T-grid Ceiling

SECTION NON-STRUCTURAL METAL FRAMING

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description

Ecophon Master Ds. System range. Size, mm. 600x600 T24. Thickness (THK) 40 M236, M242. Inst. Diagr. Pharmakon,, Denmark

DID YOU KNOW THAT. Knauf Danoline acoustical ceilings and walls can meet your national requirements in terms of acoustics?

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Clip-in and hook-on ceilings

SECTION (09512) - ACOUSTICAL TILE CEILINGS

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems SYSTEMS GUIDE

Tiles can be simply lifted out of the suspension system to gain access to the ceiling void.

ULTIMA Vector SAHARA Vector

CI/SfB. April ROCKFON MediCare Accessories

Ecophon Focus E. Connect grid and accessories. The grid is manufactured from galvanized steel.

(Suited for seismic categories A, B, C, D, E, F)

SECTION ACOUSTICAL CEILING SYSTEMS

SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS

SAS International Ltd. System 120 By SAS International Ltd. Product summary page for System 120 generated by ribaproductselector.

Ecophon Master Rigid A

THIS SECTION IS BASED ON ROCKFON S CURVGRID ONE-DIRECTIONAL CURVED METAL CEILING PANELS.

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

CEILING SYSTEMS ORCAL AXAL VECTOR. Technical Data Sheet. Semi-concealed system on exposed 24mm grid. [ Between us, ideas become reality.

system 130 modular lay-in tiles (exposed grid) SAS International +44 (0)

Installation Instructions

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

SECTION ACOUSTICAL PANEL CEILINGS

CEILING SYSTEMS ORCAL AXAL VECTOR. Semi-concealed system on exposed 24mm grid. Technical Data Sheet. [ Between us, ideas become reality.

LINEAR METAL CEILINGS Section

Suspended, Fire Rated Marine Ceiling System

SPECIFICATIONS (unless noted otherwise)

References in blue are general indicators to the specifier. If not used it can be deleted, but may be needed in the future.

LAUDER LINEA COMPLIANCE WITH BELGIAN STANDARD INTERIOR / SUSPENDING CEILING NBN LAUDESCHER BELGIAN STANDARD NBN 713.

Frengerwarm. heating panel. an FTF Group Company. the future of space conditioning

SHAPE YOUR WORLD ROCKFON MONO ACOUSTIC MONO BY NAME, MULTIPLE BY NATURE

Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector

Knauf C-Form Suspended Ceilings

Chicago Metallic 200 Snap Grid 15/16

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

Distinctive look with floating tile effect. Acoustic ceiling with low installation depth. Exceptionally easy to install and demount giving quick and

6" MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

maintenance-free free from painting easy to install Fixing Guide Cedral Click

Transcription:

System description ROCKFON SYSTEM T24 XL A, E Visible/Semi-concealed ceiling system Standard A EDGE E very tile is demountable and fewer hangers allow easy access to ceiling voids SYSTE GRP WAR YEARS NT Y T ypically at least 20 % quicker and easier to install M RA wide visible grid with A edge tiles or semi-concealed E edge tiles 1 800 mm cross tees resulting in 33 % less suspension points when compared to other systems IT LIM ED Ceiling system with a 24 mm E EDGE

DESCRIPTION Rockfon System T24 XL A, E is used to create a semi-concealed (E edge) or visible (A edge) grid ceiling system. It combines the Chicago Metallic T24 Click 2890 grid and A or E edge Rockfon tiles. With Rockfon System T24 XL A, E, 33 % less hangers are needed for installation and 33 % of levelling work is eliminated compared to a traditional T24 visible/semi-concealed grid ceiling system. Rockfon System T24 XL A, E is characterised by its quick and easy installation due to its limited number of components. It provides easy access to service installations in the plenum due to the small number of hangers required. Main runners in Rockfon System T24 XL A, E are installed at 1800mm centres which provides a quick, easy and cost effective installation. The system can be installed either directly to the soffit or suspended at a suitable height. Main runners and cross tees have a visible width of 24 mm. All components are made from galvanized steel with a smooth, white surface. The grid system can be combined in many different ways to suit a wide range of tile and plank dimensions. Main runners and cross tees have an equal height of 38 mm giving higher stability and easy integration of services. 6 max. 40 mm 4 600 mm 3 2 1 600 mm 1800 mm A 12 / 2 E (Leaning) 10 20 / 2 E (Straight) 6 / 8 12 / 2 Click system providing quick and easy installation and demounting. 38 mm full height main runners and cross tees for stability and easy service integration. A and E edges ensuring quick installation and full demountability. 2

SYSTEM COMPONENTS AND CONSUMPTION GUIDE MODULE SIZE (MM) TILE CHICAGO METALLIC T24 CLICK 2890 WALL ANGLES ACCESSORIES A/E edge 1 2 3 4 6 7 Main runner T24 Click/Hook 3600 Cross tee T24 Click 600 Cross tee T24 Click 1800 CONSUMPTION/M² W Shadow moulding wall angle Perimeter wall angle trim Wire suspension hanger Direct fixing bracket 600 x 600 2.78 pcs/m² 0. lm/m² 1.11 lm/m² 1.67 lm/m² 1) 1) 0.46 pcs/m² 0.46 pcs/m² 900 x 600 1.8 pcs/m² 0. lm/m² 0. lm/m² 1.67 lm/m² 1) 1) 0.46 pcs/m² 0.46 pcs/m² 1800 x 600 0.93 pcs/m² 0. lm/m² - 1.67 lm/m² 1) 1) 0.46 pcs/m² 0.46 pcs/m² 1) Consumption depends on room size. TILE - A AND E EDGE A EDGE E EDGE CHICAGO METALLIC T24 CLICK 2890 1. MAIN RUNNER T24 CLICK/HOOK 3600MM 2. CROSS TEE T24 CLICK 600MM 3. CROSS TEE T24 CLICK 1800MM WALL ANGLES 4. W SHADOW MOULDING WALL ANGLE. PERIMETER WALL ANGLE TRIM ACCESSORIES 6. WIRE SUSPENSION HANGER AND RIGID ANGLE HANGER 7. DIRECT SUSPENSION CLIP 3

PERFORMANCE System load bearing capacity MAX. LOAD (KG/M²) HANGER DISTANCE (MM) MODULE SIZE (MM) MAX. 2.MM DEFLECTION MAX. 4.0MM DEFLECTION 1200 600 x 600 2.8.2 1200 900 x 600 3.0.3 1200 1800 x 600 3.3.7 For 1800 x 600 mm tile, the use of stabilising profiles is recommended in case extra load is applied on the system. Contact Rockfon for more info. The system's load capacity is determined from a max. deflection of the individual components corresponding to 1/00 of the span or the cumulative deflection of all structural components which does not exceed 2. or 4 mm. The load bearing capacity is given as regularly distributed load in kg / m 2, the weight of the tile is not included. Corrosion resistance Class B (EN13964) Demountability Tiles mounted in Rockfon System T24 XL A, E are fully demountable. Fire resistance Some Rockfon ceiling systems have been tested and classified in accordance with European norm EN 1301-2 and/or national norms. Please contact ROCKFON. 30 YEARS System warranty All Rockfon ceiling systems have a 30 year limited system warranty. Contact Rockfon for more information. COMPATIBLE TILES OVERVIEW All Rockfon A and E edge tiles available in dimensions mentioned in the "System load bearing capacity" table above can be installed in Rockfon System T24 XL A, E. Other dimensions can be installed in Rockfon System T24 XL A, E. Please contact Rockfon. 4

GRID INSTALLATION Grid layout and hanger location Rockfon A and E edge tiles can be installed in Rockfon System T24 XL A, E. Some layout options are shown below depending on the size of the tile. 1200 mm 1 600 600 2 1 900 600 2 1 1800 600 1 Main runner Cross tee Hanger 1800 mm Installation requirements During and after grid installation, it is important to check that T profiles are perfectly aligned horizontally. A maximum level difference of +/- 1 mm is recommended between profiles and should not be added. This tolerance is valid for all directions. It is also important to check the squareness of the angles between the main runners and cross tees. This can be easily done by comparing the measurements of the two diagonals. See recommended tolerances in the table below. L mm MODULE SIZE (L X W) DIAGONAL (D) TOLERANCE MM W mm D mm 600 x 600 814.6 900 x 600 1048.4 +/- 1,0 1800 x 600 1980.3

MINIMUM INSTALLATION DEPTH (MM) Tiles installed in Rockfon System T24 XL A, E are fully demountable. The installation depth is defined as the distance from the under side of the tile to the underside of the substrate, where the hangers are fixed. D is the minimum installation depth for easy tile installation and demountability. TILE THICKNESS MODULE SIZE D MM 1 600 x 600 100 20-2 600 x 600, 900 x 600, 1800 x 600, 30 200 D 6

PERIMETER FINISH OPTIONS Below are examples of perimeter finishing. Further details can be found on www.rockfon.co.uk 1. A edge - Perimeter finish with wall angle trim 2. E edge - Perimeter finish with shadow wall angle trim 7

SERVICE INTEGRATION Rockfon ceiling tiles are easy to cut and therefore it is very easy to integrate services in Rockfon tiles. The cut-outs can be made with a simple utility knife. When the ceiling system is load bearing, Rockfon recommends using support arms or a yoke that transfers the weight of the service to the grid. The size of the yoke should not be bigger than module 600 x 600 mm and the use of additional hangers to overcome deflection in the ceiling system is strongly recommended. When using support arms to spread the weight of the installation, Rockfon recommends spanning a maximum of 600 mm. For more information on the load bearing capacities of this Rockfon system XL T24 A/E please refer to the table below. System load bearing capacity MAX. LOAD (KG/M²) HANGER DISTANCE MODULE SIZE (MM) MAX. 2. MM DEFLECTION MAX. 4.0 MM DEFLECTION 1200 600 x 600 2.8.2 The system s load capacity is determined from a max. deflection of the individual components corresponding to 1/00 of the span or the cumulative deflection of all structural components which does not exceed 2. or 4.0 mm. The loading capacity is given as regularly distributed load in kg / m 2, the weight of the tile is not included. Planning A thorough planning and installation scheduling of the project/site will result in less re-work and less ceiling tile damage. Rockfon recommends discussing the installation planning thoroughly and well in advance with other installers that have to work in or near the suspended ceiling. By doing so damaged ceiling tiles and dirty spots on the finished ceiling surface can be reduced, which reduces project costs. Overview load bearing capacity Small service integration; Spotlight or downlight, speaker, ventilation etc. Large service integration; Downlight, speaker, ventilation, etc. Modular lighting- or ventilation fixture WEIGHT OF INSTALLATIONS < 0.2KG/PCS 0.2 3.0KG/PCS > 3.0KG/PCS Drawing A Drawing B Independently suspend Drawing A Drawing B Independently suspend Drawing C; System load bearing capacity (if uniformly distributed over grid in kg/m 2 ) When installing services in Rockfon System T24 XL A, E you should always follow local building regulations if more strict than the load bearing capacity constraints Rockfon recommends in the above table. Contact your local Rockfon technical service for more information on suitable lighting fixtures, accessories and the availability of CAD drawings of the different services integrated in Rockfon System T24 XL A, E. Special solutions with integrated services are, if available, shown on page 12 of this document in the Tools section. 8

Drawing A The integration of a spotlight, smoke detector, speaker, etc. (weighing < 0.2kg/pcs). Rockfon recommends installing spotlights and downlights centralised in the tile. Drawing B The integration of a downlight, spotlight, smoke detector, loud speaker, etc. (weighing 0.2 3.0kg/pcs). Use of an appropriate yoke to spread the load to the grid (as shown in the detail) or use of support arms to spread the load to the grid system is strongly recommended. The use of additional hangers to avoid excess deflection and a centralised installation of the lighting in the tile is strongly recommended. Drawing C The integration of a modular luminaire or air vent (evenly distributed over grid), weighing max. the system loading capacity. If the load capacity of the system is likely to be exceeded it is strongly recommended to suspend the service independently. Alternatively use services equipped with supporting arms on minimum two opposite sides to transfer the weight of the service to the top of the bulb of the grid. This is safer and reduces the likelihood of cross tee rotation. 9

SPECIFIC SOLUTIONS Suspension clip This clip can be twist fixed on the bottom of the T24 profile and gives the possibility to suspend signs or advertisments underneath the clip. The clip is in the same colour (white) as the grid. DLC clip as a bridge for suspension main runner A DLC clip can be used to connect profiles to one another without the use of cross tees to create multi-layer grid constructions. This is particularly useful to work around obstacles and services such as light fixtures, ventilation ducts and pipes when these interrupt the primary grid layer. For corridors or large tile dimensions, using a multi-layer grid layout will save on the amount of hangers and will lead to a neat and tidy installation. Bracket 90 A 90 bracket gives you the freedom of installing a cross tee on a main runner or cross tee whithout having a slot available. Due to it s height it gives the profile the exact installing height to make a smooth connection. 90 bracket can also be used to attach/fix the profiles against the wall. 10

GENERAL INSTALLATION RECOMMENDATIONS Perimeter finishing Junction between ceiling and wall or other vertical surface The perimeter trim should be fastened to vertical surfaces at the required level using appropriate fixings at every 300-40 mm centres. Ensure that butt joints between adjoining lengths of trim are neat and that the trim is free from kinks and remains true and level. For the best aesthetics, use as long a length of trim as possible. The minimum recommended cut length is 300 mm. Perimeter trims Timber trims, timber shadow battens and metal. Shadow mouldings should not be used with fire resisting/protecting ceilings. Junction between ceiling and curved vertical surface The use of a preformed curved perimeter trim is the most appropriate method. Rockfon can provide details of curved perimeter trims on request. Tiles We recommend the use of clean nitrile or PU coated gloves when installing Rockfon tiles in order to avoid fingerprint marking on the surface. For an optimum work environment, we recommend installers always observe common work practices and follow the installation advice as shown on our packaging. Cutting is made easy with a sharp knife. All off-cuts and holes must be treated according to local Building Regulations. Note! Certain smooth matt surfaces are directional. To ensure consistency of the finished ceiling, it is important that all tiles are installed in one direction indicated by the arrow printed on the back of each tile. Corners Perimeter trims should be neatly mitred at all corner joints. Overlap mitres are acceptable on metal trims on internal corner joints unless specified otherwise. Suspension grid Unless specified otherwise, the ceiling should be set out symmetrically and where possible, perimeter tiles should be greater than 200 mm in width. The hangers should be fastened with appropriate top fixings and to the main runners at 1200 mm centres (or less with greater load). Main runners should be positioned at 1800 mm centres at all times. The centres distance of the cross tees depends on the module size of the tiles. For proper grid installation, make sure the T profiles are perfectly aligned horizontally and diagonals of modules are equal (see requirements and tolerances on page ). Main runner joints should be staggered and there should be a hanger positioned within 10 mm of the fire expansion element/cut-out and within 40 mm of the end of the main runner where it terminates at a perimeter. Additional hangers may be necessary to support the weight of ceiling services. When using direct hangers, a fixing pin should be used to lock the hanger on to the bulb of the main runner. 11

TOOLS Rockfon has developed specific tools that are available on www.rockfon.co.uk For further information visit the CAD library on our website Generate specification texts for our products Explore our vast library of reference projects 12

06.2017 All colour codes mentioned are based on the NCS - Natural Colour System property of and used on licence from NCS Colour AB, Stockholm 2010. Subject to alterations in range and product technology without prior notice. Rockfon accepts no responsibility for printing errors. Rockfon ROCKWOOL Limited T/A ROCKFON 14th Floor, Chiswick Tower, 389 Chiswick High Road, London, W4 4AL Tel: +44 (0) 208 222 747 www.rockfon.co.uk