SECTION Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco Ceramic Tile.

Similar documents
SECTION Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco Ceramic Tile.

***************************************************************************************************************

SECTION ACOUSTICAL CEILINGS

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

SECTION NON-STRUCTURAL METAL FRAMING

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

Construction Standards PAGE

SECTION NON-STRUCTURAL METAL FRAMING

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

Union County Vocational - Technical Schools Scotch Plains, New Jersey

THIS SECTION IS BASED ON ROCKFON S TRADITIONS METAL CEILING PANELS.

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

SECTION ACOUSTICAL TILE. *(Filed Sub-Bid Required) 1.00 TIME, MANNER AND REQUIREMENTS FOR SUBMITTING SUB-BIDS

SECTION LINEAR METAL CEILINGS

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Student Services & Classroom Addition

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

SECTION ACOUSTICAL PANEL CEILINGS

SECTION (09512) - ACOUSTICAL TILE CEILINGS

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

THIS SECTION IS BASED ON ROCKFON S CURVGRID ONE-DIRECTIONAL CURVED METAL CEILING PANELS.

SECTION ACOUSTICAL CEILINGS

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Section GYPSUM DRYWALL

Geometrik Manufacturing Inc.

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

1. Acoustical panels. 2. Exposed suspension systems for ceilings. 3. Wire hangers, fasteners, main runners, cross tees, and wall angle moldings.

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE D LAY-IN METAL CEILING PANELS.

THIS SECTION IS BASED ON ROCKFON S SPANAIR HOOKON METAL CEILING PLANKS.

SECTION ACCORDION FOLDING PARTITIONS

UniSpec II - Store Planning

SECTION AXIOM INDIRECT FIELD LIGHT COVE PERIMETER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION ACOUSTICAL CEILING SYSTEMS

SECTION ( Specialty Ceilings) TBAR LED Smartlight Acoustical Ceiling Integration

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE SNAP-IN METAL CEILING PANELS.

METAL SUSPENSION SYSTEMS FOR LAY-IN PANEL CEILINGS: 2001 CBC IR

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

SECTION ACOUSTICAL PANEL CEILINGS

SECTION LINEAR METAL CEILINGS

OCALA INTERNATIONAL AIRPORT MBI PN: GENERAL AVIATION TERMINAL JANUARY 16, 2018 ADDENDUM-ISSUE

LINEAR METAL CEILINGS Section

Geometrik Manufacturing Inc.

SECTION GYPSUM BOARD ASSEMBLIES

EXTERIOR PLANK SERIES SPECIFICATION DATA

SECTION ACOUSTICAL CEILINGS

SECTION CEMENTITIOUS WOOD FIBER DECKS

SECTION LIGHTING. A. Section Basic Electrical Materials and Methods

SECTION ACOUSTICAL PANEL CEILINGS. A. Section includes acoustical panels and exposed suspension systems for ceilings.

SECTION COMPOSITE CORE ACOUSTICAL PANEL CEILINGS. Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

General applications. Fast. Easy. Customer Focused.

1. This addendum contains the specifications for Acoustical Ceilings: public areas Lobby, Breakfast Room, etc. and not used on all doors.

SECTION WALL AND DOOR PROTECTION

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

SECTION GYPSUM BOARD ASSEMBLIES

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Code Compliance Meets the requirements for suspended ceilings in accordance with the 2012 International Building Code.

Ceiling Systems. Technical Guide

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION DRYWALL GRID LINEAR LIGHTING INTEGRATION

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

SECTION METAL STUDS, METAL LATH, SUSPENSION CEILINGS, PLASTER, AND STUCCO

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION Axiom Roller Shade Integration

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

HIR 1 ACOUSTICAL, IMPACT RESISTANT, TACKABLE WALL PANEL SPECIFICATION

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

SECTION GYPSUM BOARD ASSEMBLIES

A. Product Data: Submit manufacturer's product data for cementitious materials, lath, metal support components, and accessories.

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION DECORATIVE METAL RAILINGS

1. Hangers and supports for electrical equipment and systems.

Construction Standards PAGE

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

where high efficiency is the standard

A. Submit the following in addition to the standard requirements.

Make Waves. Topo 3-Dimensional System

SUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

SECTION ACOUSTICAL WALL TREATMENT (CEMENTITIOUS WOOD FIBER WALL PANELS)

SECTION GYPSUM BOARD

SECTION STEEL DECKING

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

SECTION COMPOSITE METAL DECKING

SECTION GYPSUM BOARD

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECTION GYPSUM BOARD SYSTEM

Transcription:

SECTION 09510 ACOUSTICAL CEILINGS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09200 - Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco. 2. 09310 - Ceramic Tile. 1.02 REFERENCES A. American Society for Testing and Materials (ASTM): 1. A653-96 Standard Specification for Steel Sheet, Zinccoated (Galvanized) or Zinc-iron Alloycoated (Galvannealed) by the Hot-dip Process. 2. C635-95 Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings. 3. C636-96 Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels. 4. E1264-96 Classification for Acoustical Ceiling Products. B. Ceiling and Interior Systems Contractors Association (CISCA) publication (current edition): Acoustical Ceilings - Use and Practice. C. Underwriters Laboratories (UL) fire rating listings and classifications. 1.03 SUBMITTALS A. Submit properly identified product data, including properties of lay-in panels, fire tests, details of suspension grid system, and installation instructions for review before starting work. B. Shop Drawings: As may be required by A/E. Coordinate grid erection drawings with lighting fixtures, air-conditioning outlets, access panels, sound system, and other openings and irregularities. Project No. SPECIFICATION GUIDELINES 09510-1

C. Samples: Submit identified samples of each of the following for review and selection: 1. Exposed grid suspension system with angle. 2. Acoustical lay-in panel, 12 inches square piece. PART 2 PRODUCTS 2.01 MATERIALS A. Acoustical Lay-in Panels, Mineral Fiber Type: 2. Complying with ASTM E1264, Class A, Type 3, Form 2, square edged. 3. 4. Nominal Thickness: 5/8". Finish: Factory applied, washable white. a. Armstrong: Minaboard #756 Fissured lay-in b. Celotex: Hytone DMRF-157 Fissuretone II lay-in c. USG Interiors: Auratone #560 Fissured lay-in panel. B. Acoustical Lay-in Panels, Fire Rated Mineral Fiber Type: 2. Complying with ASTM E1264-90, Fire Rated, Class A, Type 3, Form 2, square edged. 3. Nominal Thickness: 5/8". 4. Finish: Factory applied, washable white. 5. Weight: 1 pound per square foot minimum. 6. Manufacturers: a. Armstrong: Minaboard #896 Fissured Fire Guard layin b. Celotex: Hytone Fissuretone II PDRF-157 Protectone lay-in c. USG Interiors: #585 Fissured Fire Code lay-in C. Vinyl Faced Lay-in Panels, Gypsum Type: 2. Gypsum, complying with ASTM E1264, Class 3, Type 3, Form A. 3. Nominal Thickness: 1/2". 4. Finish: Factory applied 0.002" vinyl, washable white. Project No. SPECIFICATION GUIDELINES 09510-2

a. Celotex: Clean Room VTS-857 Vinyltone lay-in panels b. USG Interiors: Clean Room #3260 Stipple pattern lay-in D. Acoustical Lay-in Panels, Wood Fiber Type: 1. Wood fiber, complying with ASTM E1264, Class A, Type XX, square edge. 2. Minimum Thickness: 1-1/2". 3. Size: 23-3/4" x 47-3/4". 4. Finish: Factory applied, white. a. Tectum Inc. "Tectum". b. Or accepted equivalent. E. Acoustic ceiling baffles (sound absorbers with noncorrosive grommets) shall be used in active spaces such as gymnasiums, shops, etc. 1. Size: 2 feet x 4 feet x 2 inches. 2. Finish: UL listed, "Nubby" glass cloth fabric, or accepted equivalent. Painted "Nubby" cloth is acceptable if painting is done by the manufacturer and the NRC factor has not been affected by the process. 3. Color: White or standard colors offered by the manufacturer, as selected by the A/E. 4. Noise Reduction Coefficient (NRC): 0.90 to 1.0. a. Capaul Corporation. b. Metal Building Interior Products Co.: Cloud-Lite. c. Sound Concepts, Canada Inc. F. Hangers: 12 gage (0.109" diameter) annealed steel wire, galvanized. G. Exposed Suspension Grids For Acoustical Lay-in Panels: 1. 2 feet x 2 feet grid pattern with steel caps for exposed grid tee and angle members complying with ASTM C635, zinc-coated or hot-dipped galvanized complying with A653, factory painted steel parts with factory applied white baked enamel or polyester finish. ****** ***** **** *** ** * ** *** **** ***** ****** Note to Specifier: Use one of the 3 following suspension systems at cafeteria kitchens, salad bars, snack bars, and serving areas. ****** ***** **** *** ** * ** *** **** ***** ****** Project No. SPECIFICATION GUIDELINES 09510-3

2. 2 feet x 2 feet grid pattern, complying with ASTM C635, hot-dipped galvanized steel tee and cap, painted cap, and stainless steel clips. 3. 2 feet x 2 feet grid pattern, complying with ASTM C635, hot-dipped galvanized steel tee, painted aluminum cap, and stainless steel clips. 4. 2 feet x 2 feet grid pattern, complying with ASTM C635, aluminum tee, painted aluminum cap, and stainless steel clips. a. Armstrong. b. Celotex. c. Chicago Metallic Corporation. d. USG Interiors, Inc. (Donn). PART 3 EXECUTION 3.01 INSTALLATION A. Powder activated fasteners are not allowed. 1. Coordinate and provide inserts, anchors, bolts, hangers, or other means to support ceilings suspended from structure. 2. Drill structure as needed to support equipment if inserts have been omitted from the concrete structure. B. Install specified suspension system and acoustical lay-in panels according to ASTM C636 and CISCA Publication "Acoustical Ceilings - Use and Practice", and applicable manufacturer's printed instructions. 1. Complete partitions indicated to be extended to overhead construction with finishes applied before installation of ceilings abutting such partitions. 2. Provide one hanger minimum for each 16 square feet of ceiling. a. Locate hanger wire not more than 1 foot away from main runners resting on wall trim. C. Acoustical Lay-in Panels: 1. Fit acoustical lay-in panels to grid accurately, without dented, broken, cracked, chipped, or soiled surfaces. 2. A cut panel shall be a size that will not expose an Project No. SPECIFICATION GUIDELINES 09510-4

edge when the panel is slid to the opposite side. D. Light Fixtures: 1. Fit acoustical lay-in panels accurately around surface mounted and stem mounted electrical fixture outlets. 2. Adequately support tees supporting light fixtures by hanger wires so grid is level after light fixture installation. E. Alignment: a. Provide a hanger wire within 3 inches of each recessed lay-in light fixture corner. 1. Align suspension members for true level surfaces and straight lines. Run joints and exposed grid members parallel to the room axis in both directions. 2. Install exposed suspension grids per installers accepted grid layout drawings, properly coordinated with air conditioning and electrical trades. F. Border Balance: 1. Balance border areas to avoid acoustical units less than 1/2 unit wide. G. Textured or Patterned Acoustical Panels: Install in pattern in one direction including grain of panels with alternating grain, unless otherwise directed in writing by A/E. 3.02 ADJUSTING AND CLEANING A. Replace dirty or discolored acoustical panel surfaces following erection and leave free from defects. B. Remove damaged or improperly installed acoustical panels and replace. END OF SECTION Project No. SPECIFICATION GUIDELINES 09510-5