Copyright 2002 AIA MASTERSPEC 05/02

Similar documents
Multi-Institutional Academic Health Science & Research Center Evansville, IN

Construction Standards PAGE

SECTION CLEAR PENETRATING SEALERS SPECIFICATION

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

SECTION Silane Water Repellents. Vexcon

CHATTANOOGA, TN Last Updated: 02/07/18. NOTE TO SPECIFIER: Be sure to obtain the latest version of this Guide Specification.

Section SECTION RESINOUS FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

KOSTER AMERICAN CORPORATION

***********************************************************************************

SECTION EPOXY TERRAZZO

FLEXMAR 3-Coat High-Build Colored Quartz System

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

(Specification writer shall choose the most appropriate section that applies to a given scope of work) SECTION Painting and Coating

Product Guide Specification

CSC SPECIFICATIONS DRY SHAKE CRYSTALLINE WATERPROOFING Section

CSI SPECIFICATIONS DRY SHAKE CRYSTALLINE WATERPROOFING Section

A. Section includes historic treatment work consisting of rep ointing brick masonry as follows:

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

SECTION A. American Society for Testing and Materials (ASTM):

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Products

SECTION A. American Society for Testing and Materials (ASTM):

ZYCOSIL WATER REPELLENT

SECTION A. American Society for Testing and Materials (ASTM):

Custom Polishing Systems

Seal- Krete High Performance System

Dryshake CSI Format Section 07160

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

Pacific Polymers Elasto-Mat D&G Guide Specification

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

80648 StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

CEMENTITIOUS CRYSTALLIZING WATERPROOFING PART 1 GENERAL

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

List walls, planters, etc.., to which the anti-graffiti coating will be applied. Delete this note from the Contract Specifications.

SECTION A. American Society for Testing and Materials (ASTM):

Part 1 - GENERAL 1.01 DESCRIPTION. Section

1.1 Related Work Specified in Other Sections (Delete if Not Applicable):

1.1 SECTION INCLUDES.1 The requirements for the application of water repellents/ anti-graffitiant for exterior surfaces.

Pacific Polymers Elasto-Deck BT Guide Specification

SECTION Arisfor WallGuard

ADDENDUM 1. Bid Date March 8, 2017 at 2 pm CST. March 2, 2017

80230 StoColor Coat Sand Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

SECTION PENETRATION FIRESTOPPING PART 1- GENERAL PART 2- PRODUCTS 1.1 RELATED DOCUMENTS

80657 StoColor Texture - Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

SECTION CONCRETE AND MASONRY COATINGS

EVERLAST CONCRETE TECHNOLOGIES PROTECTION PRODUCTS SECTION CONCRETE ADDITIVES AND ADMIXTURES

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

Section COATING RESTORATION

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

SECTION LITHIUM BASED MOISTURE VAPOR CONTROL CURE SYSTEM AND FINISHING

A. This Section includes resinous flooring systems with epoxy body coat(s).

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

A. This Section includes traffic coatings for the following applications:

80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Specifications. Specifications (Architectual) Metallic System. Metallic System

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX ARDIFLO Pump System Underlayments

Student Services & Classroom Addition

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Underlayments and Toppings

80201 StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Section COATING RESTORATION

SECTION RESILIENT TILE FLOORING. A. Section includes vinyl composition floor tile and accessories indicated and as specified.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Application Specification:

GUIDE SPECIFICATION SECTION CRYSTALLINE WATERPROOFING

GUIDE SPEC SECTION Injection Grout (IG10)

ChemMasters. Installation Guidelines

SECTION A. American Society for Testing and Materials (ASTM):

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Pacific Polymers Elasto-Deck 5000MR Guide Specification

FLUID APPLIED WATERPROOFING SECTION SPECIALTY COATINGS

CHATTANOOGA, TN Last Updated: 02/07/18. NOTE TO SPECIFIER: Be sure to obtain the latest version of this Guide Specification.

SC-113 STRONGCOTE VEHICULAR GRADE TRAFFIC DECK MEMBRANE SYSTEM SECTION 07570

Application Specification:

80648R StoCoat Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Section Pedestrian Traffic Coatings

SECTION BRICK MASONRY ASSEMBLIES

SYSTEM GUIDE SPECIFICATION FOR SUPER-KRETE MOISTURE VAPOR EMISSIONS TREATMENT SYSTEM S SECTION ; /19; ;

RESINOUS FLOORING

1.2 SUMMERY A. Section Includes: 1. High-Performance Polyurethane Resinous flooring systems. 2. Decorative Polyurethane Resinous flooring systems.

SECTION A. American Society for Testing and Materials (ASTM):

80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

SECTION (07100) - DAMPPROOFING AND WATERPROOFING

Jewel Stone. Decorative Concrete Overlay System. Part 1 GENERAL MANUFACTURER S SPECIFICATION

Acrylitex Tilt UP Primer Guide Specification Revised August 1, 2008

SECTION RESINOUS FLOORING PLEXIQUARTZ BROADCAST SKID-RESISTANT QUARTZ SYSTEM

SECTION SIMULATED STONE MASONRY

A. Drawings and general provisions of the Contract apply to this Section including all documentation provided in RFP#

SECTION SANDSTONE RESTORATION

Section RESILIENT TILE FLOORING INCLUDING VINYL COMPOSITION TILE

SECTION SURFACE-APPLIED CRYSTALLINE WATERPROOFING AND CONCRETE REPAIR

Ash Brook Golf Course Scotch Plains, New Jersey

ROOF REPLACEMENT AND ALTERATIONS TO WOODSTOCK Barrett Architecture, PC WASTE WATER TREATMENT FACILITY - Woodstock, VT February 28, 2019 SECTION

SECTION EPOXY MOSAIC COMPOSITION FLOORING Dex-O-Tex Cheminert Terracolor

Centenary United Methodist Church January Code Improvements & North Entry Remodel Beatrice, Nebraska ADDENDUM NO. 1

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Transcription:

SECTION 07162 - CRYSTALLINE WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes crystalline waterproofing. B. Related Sections include the following: 1. Division 3 Section "Cast-in-Place Concrete" for[ formwork, water stops, concrete slabs serving as floor toppings to protect waterproofing, and finishing concrete walls and slabs to receive waterproofing.] 2. Division 4 Section "Unit Masonry Assemblies" for preparing concrete unit masonry walls to receive waterproofing. 3. Division 7 Section "Joint Sealants" for elastomeric and preformed sealants in concrete and masonry walls and floors. 4. Division 9 Section "Portland Cement Plaster" for plaster finishes to be applied over waterproofing. C. Alternates: Refer to Division 1 Section "Alternates" for description of Work in this Section affected by alternates. 1.3 SUBMITTALS A. Product Data: Include material descriptions and installation instructions for crystalline waterproofing. B. Product Certificates: For crystalline waterproofing, signed by product manufacturer. C. Qualification Data: For installer and manufacturer. D. Manufacturer's inspection reports of completed installation. E. Warranty: Special warranty specified in this Section. 1.4 QUALITY ASSURANCE A. Installer Qualifications: An employer of workers trained and approved by manufacturer. CRYSTALLINE WATERPROOFING 07162-1

B. Mockups: Provide mockups of crystalline waterproofing to verify selections made under sample submittals and to demonstrate aesthetic effects. 1. Architect will select locations of mockups that represent typical surfaces and conditions for applications of crystalline waterproofing. a. [Vertical] [Horizontal] Surfaces: Provide samples of at least [10 sq. ft. (0.9 sq. m)] <Insert value>. 2. Apply waterproofing according to requirements for the completed Work after permanent lighting and other environmental services have been activated. C. Preinstallation Conference: Conduct conference at Project site to comply with requirements in Division 1 Section "Project Management and Coordination." Review methods and procedures related to crystalline waterproofing including, but not limited to, the following: 1. Review and finalize construction schedule and verify availability of materials, Installer's personnel, equipment, and facilities needed to make progress and avoid delays. 2. Review required certifying procedures. 1.5 PROJECT CONDITIONS A. Weather Limitations: Proceed with application only when existing and forecasted weather conditions permit crystalline waterproofing to be performed according to manufacturer's written instructions and warranty requirements. B. Proceed with waterproofing work only after pipe sleeves, vents, curbs, inserts, drains, and other projections through the substrate to be waterproofed have been completed. Proceed only after concrete and masonry substrate defects, including honeycombs, voids, and cracks, have been repaired to provide a sound substrate free of forming materials, including reveal inserts. C. Ambient Conditions: Proceed with waterproofing work only if temperature is maintained at 40 deg F or above during work and cure period and space is well ventilated and kept free of water. 1.6 WARRANTY A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to replace components of crystalline waterproofing that fails in material within specified warranty period. 1. Failures include, but are not limited to, the following: a. Failure to maintain watertight conditions within specified warranty period. 2. Warranty Period: (Five Ten) years from date of Substantial Completion. CRYSTALLINE WATERPROOFING 07162-2

PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Products: Subject to compliance with requirements, provide one of the following: 1. Crystalline Waterproofing: a. Foxfire; P-1007 b. Foxfire; PL-1007 c. Foxfire; L-1007 2. Water Repellant a. Foxfire; 5000WB b. Foxfire; 5000 WB Cure and Seal 3. Stain Repellant a. Foxfire; Stain Repellant 4. Cleaners a. Foxfire Heavy Duty Concrete Cleaner b. Foxfire Efflorescence Remover c. Foxfire Super Blue Degreaser 5. Activators a. Foxfire Catalyst 2.2 MATERIALS A. Crystalline Waterproofing: A manufacturer s proprietary one component, clear colored (potassium, potassium/lithium, and lithium) based sealer in a water carrier, when applied, penetrates by capillary action into concrete or masonry and reacts chemically with free lime in the presence of water to develop crystalline growth within concrete or masonry capillaries to produce an impervious, dense, waterproof concrete or masonry. 1. Color: Clear 2. VOC Content: None B. Water Repellant: A manufacturer s proprietary blend of one component, VOC compliant, water-based penetrating modified silane/siloxane, when applied, penetrates by capillary action into concrete and masonry pores and capillaries forming a seal that repels water, but allows water vapor permeability. 1. Color: White dries clear without changing color of substrate. 2. VOC Content: Less than 37 g/l C. Stain Repellant: A manufacturer s proprietary blend of one component, VOC compliant, waterbased penetrating fluorsilane/siloxane, when applied, penetrates by capillary action into concrete and masonry pores and capillaries forming a seal that repels water, oil and graffiti, but allows water vapor permeability. 1. Color: Clear/yellow, dries clear 2. VOC Content: Less than 50 g/l D. Cleaners: A manufacturer s proprietary water base, low VOC compliant, dilutable detergent that penetrates the concrete substrate to purge contaminants from the concrete s capillary system. Manufacturer s cleaner to be used as part of waterproofing system to assure unit responsibility. CRYSTALLINE WATERPROOFING 07162-3

E. Activators: A manufacturer s proprietary water base, colorless, non-toxic, low viscosity, nonflammable liquid formulation to increase alkali in masonry and concrete substrates. PART 3 - EXECUTION 3.1 EXAMINATION A. Acceptance of Conditions: Examine substrates, with Applicator present, where waterproofing is to be applied. 1. Proceed with application only after unsatisfactory conditions have been corrected. 2. Notify Architect in writing of active leaks or structural defects that would affect system performance. 3.2 PREPARATION A. Protect other work from damage from cleaning, preparation, and application of crystalline waterproofing. Provide temporary enclosure to confine spraying operation and to ensure adequate ambient temperatures and ventilation conditions for application. B. Stop active water leaks according to waterproofing manufacturer's written instructions. C. Repair damaged or unsatisfactory concrete or masonry according to manufacturer's written instructions. D. Surface Preparation: Surface must be free of any form of membrane Comply with waterproofing manufacturer's written instructions to remove efflorescence, chalk, dust, dirt, existing coatings, mortar spatter, grease, oils, curing compounds, and form-release agents to ensure that waterproofing penetrates concrete or masonry surfaces. E. Concrete Joints: Clean reveals according to waterproofing manufacturer's written instructions. F. ph level: Test ph content of concrete or masonry surface; ph level must be 9 or higher. If less than 9, an activator to increase ph must be used. 3.3 APPLICATION A. General: Comply with waterproofing manufacturer's written instructions for application. 1. Apply Foxfire (P-1007, PL-1007, or L-1007) to visually dry surface. 2. Apply waterproofing to [positive] [negative]-side surfaces. 3. Number of applications: [Two] [Three] for [brush] [roller] [spray] application. 4. Do not dampen surface between coats. After final application, wait 20-40 minutes and apply two mist applications of potable water 15 minutes apart to concrete surface. 5. Apply Foxfire (5000WB, Stain Repellant) to dry surface, minimum 24 hours after application of sealer. CRYSTALLINE WATERPROOFING 07162-4

6. Note: if ph level is below 9, Foxfire Catalyst should be applied in a single application at a rate of 200 sqft per gallon, a minimum of one hour prior to the application of the ( P- 1007, PL-1007, or L-1007) B. Existing Concrete and Masonry: 1. Vertical Surfaces: a. Apply from top to bottom to point of refusal using a low pressure sprayer (40 psi) with a fan-type tip. b. After first application has soaked in, normally 20-40 minutes, apply second application. d. After final application of Foxfire (P-1007, PL-1007, or L-1007) is installed, and absorbed, wait approximately 20-40 minutes and then apply two light coats of potable water to remove surface contaminants, waiting approximately 15-20 minutes between applications. 2. Horizontal Surfaces: a. Apply an application of Foxfire (P-1007, PL-1007, or L-1007) to the point of refusal using either a low pressure sprayer (40 psi) with a fan-type tip or roller with an 11/4 nap. Brush or squeegee excess Foxfire P-1007 to untreated areas b. After first application has soaked in, wait approximately 20-40 minutes prior to application of second application. d. After final application of Foxfire (P-1007, PL-1007, or L-1007) is installed, wait approximately 20-40 minutes after final application of sealer and then apply two light applications of potable water to remove surface contaminants, waiting approximately 15-20 minutes between applications. C. New Concrete and Masonry: 1. Vertical Surfaces: a. Apply from top to bottom until excess product is 6-8 inches below spray pattern using a low pressure sprayer (40 psi) with a fan-type tip or roller with an 11/4 nap. b. After first application has soaked in, normally 20-40 minutes, apply second application. d. After final application of Foxfire (P-1007, PL-1007, or L-1007) is installed, wait 20-40 minutes and then apply two light applications of potable water to remove surface contaminants, waiting approximately 15-20 minutes between applications. 2. Horizontal Surfaces: a. Apply an application of Foxfire (P-1007, PL-1007, L-1007)so the surface will have a wet glaze look, using either a low pressure sprayer (40 psi) with a fan-type tip or roller with a 11/4 nap. Brush or squeegee excess Foxfire Sealer to untreated areas b. After first application has soaked in, wait 20-40 minutes prior to application of second application. CRYSTALLINE WATERPROOFING 07162-5

d. After final application of Foxfire (P-1007, PL-1007, or L-1007) is installed, wait approximately 20-40 minutes and then apply two light applications of potable water to remove surface contaminants, waiting approximately 15-20 minutes between applications. D. Allow Foxfire (P-1007, PL-1007, or L-1007) to cure a minimum of one day after application prior application of surface topping as recommended in writing by manufacturer. Full cure may take up to seven days depending on temperature, humidity and density of concrete. E. (Water or Stain) Repellant: 1. Vertical Surfaces: a. Apply Foxfire (5000WB, Stain Repellant) from top to bottom until excess product is 6-8 inches below spray pattern using a low pressure sprayer (15-25 psi) with a fan-type tip or roller with an 11/4 nap. Re-apply wet-on-wet second application within 2-3 minutes of first application. 2. Horizontal Surfaces: a. Apply an application of Foxfire (5000WB, Stain Repellant) using either a low pressure sprayer (15-25 psi) with a fan-type tip or roller with an 11/4 nap. Reapply wet-on-wet second application within 2-3 minutes of first application. 3.4 PROTECTION A. Protect applied crystalline waterproofing from severe weather exposure and water accumulation until surface is dry. 3.5 FIELD QUALITY CONTROL A. Testing: To be established by specifier. Testing can include both the Anhydrous Calcium Chloride Vapor Emission Test, the Tramex Concrete Moisture Encounter Meter Tester for Flooring or Rilem Tube testing for wind driven rain on horizontal or vertical surfaces. All surface readings must be documented by date and time-stamped photos. Test criteria to be established by specifier. B. Inspection: Manufacturer's representative to inspect completed application and to provide a written report that application complies with manufacturer's written instructions. END OF SECTION 07162 CRYSTALLINE WATERPROOFING 07162-6