Insulation boards PhoneStar

Similar documents
Insulation boards PhoneStar

Please Note: PhoneStar was previously branded as Phonewell

Egger Ergo Board This board allows you to take it easy.

Bavaria. PowerFloor. PhoneStar. SYSTEM SOLUT ions FOR TIMBER FRAME HOUSES AND REFURBISHMENTS DRY SCREED UNDERFLOOR HEATING SOUND INSULATION

ARSTYL WALL PANELS STONE

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

THE SOUND INSULATION. B a v a r i a

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING

Container Installation Guide

hüma PARKETTSYSTEM GmbH INSTALLATION GUIDE

SOUND INSULATION UNDERFLOOR HEATING DRY SCREED. PHONESTRIP Decoupling strips for timber frame and CLT constructions

Specialists in Acoustic Flooring and House to Flat Conversions

ARSTYL WALL PANELS STONE

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels

lindab we simplify construction LindabSandwichPanels Installation instructions Mineral Wool Panels

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

Metal Web Floor System

INSTALLATION INSTRUCTIONS FOR WICANDERS 2G FLOORS

EI 30 barriere Self contained fire protection EI 30 from above and below smoke impervious EN

Conergy SolarFamulus II

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS

HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION GTEC MOISTURE AND VAPOUR BOARD WITH PLASTERBOARD

The CLAYTEC clayboard is a dry lining board for internal use made of reed-reinforced

HOMEGA DESCRIPTION. UNIQUE PATENTED PRODUCT ON THE MARKET US Patent No CAN Patent No

The Revolutionary New Plasterboard TIMBER FRAME GUIDE

1. What are the benefits of Decorative Wall Panels? 2. Where can these decorative panels are used? 3. Are the panels waterproof?

VESDURA VINYL PLANKS 7.5MM WPC CLICK LOCK - AMERICANA COLLECTION

VESDURA VINYL PLANKS 5.5MM WPC CLICK LOCK - AMERICANA COLLECTION

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

Container Installation Guide

INSTALLATION INSTRUCTIONS LAMINATE

Cembrit Windstopper Basic Cembrit Windstopper Extreme

INSTALLATION INSTRUCTIONS FOR WICANDERS 5G-C FLOORS

Independent twin frame high performance acoustic separating wall system

DUOline. The innovative product line with. More functions More performance More security NEW. fischer DUO - Line. More power, more intelligence

Thermal Laminate Board.

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Insulation: types. 1. Loose fill 2. Matt and blankets 3. Rigid board 4. Injected. D. O Dowd

Impression Graphic panels

Installation Procedure of Floating floors

ALTOGETHER CONVINCING SANITARY TECHNOLOGY. Technical Information and. Subject to technical change

Voie Romaine F Maizières-lès-Metz Tel.: +33 (0) Fax.: +33 (0) Operating vacuum pressure: - 500Pa

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES GTEC THERMAL BOARD WITH PLASTERBOARD

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

S 01 Modules WC I-IlI

GypWall QUIET Acoustic separating wall system

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

PROTEKTOR PROFILES FOR EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

Technical Data Sheet

INSTALLATION INSTRUCTIONS FOR WICANDERS HYDROCORK

MAKING IT STICK: Nails and screws, adhesives and compounds... today contractors have a wide variety of choices.

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

OPTIMA Dry Lining System. High Performing, Easy & Quick INSTALLER GUIDE

INSTALLATION INFORMATION

DUOline. The innovative product line with. More functions More performance More security. fischer DUO - Line NEW. More power, more intelligence

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Installation Guide. PAROC panel solutions

SOUND INSULATION UNDERFLOOR HEATING DRY SCREED. DRY SYSTEM SOLUTIONS Suitable for floors, walls and ceilings in new build and retrofit

CONCRETE SCREEDS, INTERIOR FLOORING AND WALL COVERINGS. BME Lepel, Adrienn PhD

SECTION SOUND ISOLATION

Ventura Office Partitions. Technical guide

QuietRock 530 RF Application Notes

L. W. Mountain, Inc. Floating Glue Installation Instructions *For use with engineered floors only*

mcr Silboard self-supporting ventilation and smoke extraction ducts

FERMACELL DRY FLOORING ELEMENTS: IMPROVED LIVING CONDITIONS THROUGH BETTER ACOUSTIC AND THERMAL INSULATION. Dry Lining

Parabond 600 Elastic glue and adhesive with extremely high initial bonding

SubPrimo. subprimo. Acoustic insulation for timber & laminate flooring. Uniclass L5395:N372 EPIC E485:Y45. CI/SfB (43) T (P2)

pinta PLANO Service [1/7]

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Metal Door Frames & Meter Boxes

fermacell Powerpanel H 2 O Linear Shower Outlet 2.0

June Non - Residential New Build Partition walls

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)

INSTALLATION GUIDE GUIDE TO ASC ISO-WALL CONSTRUCTION SYSTEM APPLICATION ISO-WALL SYSTEM. ASC Iso-Wall System Includes: Materials Required:

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Knauf Aquapanel Interior. System Solutions Tile Backing. Cement board for wet areas. Quick and simple to construct

SECTION GYPSUM BOARD

Installation Guide and Safety Manual

Cl/SfB 1 (4-) 1 RJ December 2018 (2) Cempanel. Cement Particle Board - Building board for external and internal applications

INSTALLATION INSTRUCTIONS

Insulation and Technologies

BioPrism Solid Surface

Product Guide Specification

COMP ONENT CATA LO GUE FOR B UILDING YO UR OWN HOME

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

Exterior Wall Solutions Building Shell

GUIDE TO DUKKABOARD AQUA 77

GypWall QUIET Acoustic separating wall system

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips)

Platform stair lift PLG7

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

SKAMOTEC 225 INSTALLERS GUIDE For 1-1/2 Thickness

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Product Guide Specification

Transcription:

Sound Insulation Bavaria Insulation boards PhoneStar Installation instructions Wall Version 15.05. 2015

ONE solution universal in every area PhoneStar is an innovative, very efficient insulation board comprised of the environmentally friendly basic materials of wood and sand or more precisely, corrugated cardboard and highly compressed quartz sand. PhoneStar very efficiently insulates airborne and impact sound with low panel thickness and airborne sound with low wall thicknesses. Introducing the PhoneStar family: Area of application: Floor, wall and ceiling PhoneStar TRI - Triple wall parallel - Dimensions: 1250 x 625 x 15 mm - Dimensions: 1200 x 800 x 15 mm PhoneStar TWIN - Double wall parallel - For thin installations - Dimensions: 1250 x 625 x 10 mm - Dimensions: 1200 x 800 x 10 mm Area of application: Floor PhoneStar PROFESSIONAL - Three wall crossed - Dimensions: 1200 x 800 x 15 mm 10 benefits that inspire» Very good airborne sound insulation and impact sound insulation» Low board thickness of 10 or 15 mm» Quick, clean and simple installation» Natural basic materials for sustainable construction» A universal solution for floors, walls, and ceilings» Very high pressure resistance» All types of end flooring possible on floor» Comfortable living environment, buffers heat and moisture» More living space due to low panel thickness» Increased property value due to superior sound insulation 2 Installation instructions Wall 2

Table of Contents A - Before assembly A1. Environmental conditions for Phonestar - FOLLOW THESE INSTRUCTIONS!...4 A2. Wolf Special Products...5 A3. Overview of wall installations...6 A4. Electrical installation...8 A5. Installation times...9 B - PhoneStar installation & assembly B1. PhoneStar cutting and taping...10 B2. General instructions for PhoneStar wall mounting...11 B3. Direct mounting on solid walls...14 B4. Mounting on substructure & stud wall...17 B4.1 Existing stud walls...22 Installation instructions Wall 3

Before assembly A1. Environmental conditions for PhoneStar - FOLLOW THESE INSTRUCTIONS! Construction site conditions PhoneStar boards may only be put into closed and heated rooms under constant climatic conditions. The minimum temperature is +15 C and air humidity must be 30-60%. The environmental conditions must be documented before installation starts. Acclimatization / Storage Prior to installation, PhoneStar boards must acclimate in the installation room for a minimum of 24 hours to avoid minimal shrinkage after installation that could result in open joints or warping effects. Store the boards laid flat. Tip: Divide boards into multiple smaller piles of boards; this promotes and accelerates acclimatization compared to boards piled in one stack. Sun protection The PhoneStar boards must be protected from the sun when in storage or being laid in order to avoid minimal shrinkage that could result in open joints and warping effects Documentation requirement & disclaimer It is necessary to check environmental conditions prior to installation of PhoneStar boards (construction site conditions and moisture control on the subsurface). The measurement results must be documented and sent to Wolf Bavaria by fax or email prior to installation. Wolf Bavaria GmbH does not assume any liability in the event of non-observance of environmental conditions or the documentation requirement. Documentation log: www.wolf-bavaria.eu Downloadcenter General note: PhoneStar sound insulation boards generally require end covering (e.g. plasterboard). It is not possible to plaster, paint, wallpaper, etc., directly onto PhoneStar. 4 Installation instructions Wall

Before assembly A2. Wolf Special Products Product Image Description Wolf Tape Roll 50 m Masking of the cut edges on PhoneStar. Sealing of the joint edge area in the PhoneStar layer. Wolf System Glue Bottle 1,0 kg approx. 10 m 2 / Bottle Gluing of plasterboard on Phone Star in the variations in which Phone- Star is mounted directly on solid walls or existing stud walls. Wolf Joint Filler Cartridge 310 ml Joint sealant for wall, floor and ceiling connections. Wolf System Dowel Package: 50 / 250 units Dimensions: 6 x 60 mm (6 x 100, 8 x 120 mm) Use: 12 units / board Plasterboard screw (Plaster in plaster screw) Dimensions: 5,5 x 38 mm Package: 500 units. Use: approx. 16 units / m 2 Plasterboard screw (Drywall screw - coarse threads) Dimensions: 3,9 x 35 mm Package: 1000 units. Use: 12 units / board Plasterboard screw (Drywall screw - fine threads) Dimensions: 3,9 x 35 mm Package: 1000 units Use: 12 units / boards Plasterboard screw (Drywall screw gypsum fibre) Dimensions: 3,9 x 22 mm Package: 1000 units Use: approx. 16 units / m 2 Direct mounting of PhoneStar on solid walls. Mounting of plasterboard in Phone- Star when mounted with substructure. Mounting of PhoneStar in wooden substructure. Mounting of PhoneStar in metal substructure. Mounting of plasterboard in Phone- Star assembly without substructure, in connection with Wolf System Glue. Installation instructions Wall 5

Before assembly A3. Overview of wall installations Variation Single Double Description 1 Direct assembly 1. Solid wall 2. PhoneStar 3. PhoneStar 4. Covering* 1 2 4 1 2 3 4 *Covering screwed and additionally glued with Phone- Star together. 1. Solid wall 2. Soft wood fibre 3. PhoneStar 4. PhoneStar 5. Covering 1 2 3 5 1 2 3 4 5 2 - Substructure Lathing 1. Solid wall 2. Battens 3. Cavity insulation 4. PhoneStar 5. PhoneStar 6. Covering 1 2 3 4 6 1 2 3 4 5 6 Plume strip 1. Solid wall 2. Resilient bars 3. Cavity insulation 4. PhoneStar 5. PhoneStar 6. Covering 1 2 3 4 6 1 2 3 4 5 6 3 Facing formwork 1. Solid wall 2. Air gap approx. 10 mm 3. Substructure wooden / metal 4. Cavity insulation 5. PhoneStar 6. PhoneStar 7. Covering 1 2 3 4 5 7 1 2 3 4 5 6 7 6 Installation instructions Wall

Before assembly A3. Overview of wall installations Variation Single Double Description 4 - Stud wall Wooden stud framing 1. Covering 2. PhoneStar 3. Stud framing wooden / metal 4. Cavity insulation 5. PhoneStar 6. Covering 1 3 4 5 6 1 2 3 4 5 6 Metal stud framing 1. Covering 2. PhoneStar 3. PhoneStar 4. Stud framing wooden / metal 5. Cavity insulation 6. PhoneStar 7. PhoneStar 8. Covering 1 4 5 6 7 8 1 2 3 4 5 6 7 8 5 Existing stud wall Wooden stud framing 1. Covering* 2. PhoneStar 3. Covering 4. Stud framing wooden / metal 5. Cavity insulation 6. Covering 7. PhoneStar 8. Covering* 3 4 5 6 7 8 1 2 3 4 5 6 7 8 *Covering screwed and additionally glued with Phone- Star together. Metal stud framing 1. Covering 2. PhoneStar 3. PhoneStar 4. Covering 5. Stud framing wooden / metal 6. Cavity insulation 7. Covering 8. PhoneStar 9. PhoneStar 10.Covering 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Installation instructions Wall 7

Before assembly A4. Electrical installation In order to avoid adverse effects in the electrical installation through traditional installation elements, Wolf Bavaria recommends the use of sound insulation sockets for optimal sound insulation in the wall area. Sound insulation sockets Electrical installation with sound insulation socket for use in walls with higher requirements for sound insulation. The solid socket with additional sound insulation casing absorbs and reflects sound so that there is no negative impact on neighbouring rooms and the sound insulation works as if no installation sockets have been installed in the wall. Device connection socket with cover Kaiser item no. 9069-01 + 1184-69 Device connection socket, non-halogen Kaiser item no.: 9069-77 Electronics socket, can also be used as a double socket Kaiser item no.: 9069-94 Electronics socket, can also be used as a double socket Non-halogen design Kaiser item no.: 9069-74 Additional information available at: www.kaiser-elektro.de 8 Installation instructions Wall

Before assembly A5. Installation times Depending on the routine, the following installation times can be used as a calculating guideline when installing PhoneStar boards. Installation of PhoneStar TRI & TWIN Installation variation Direct mounting Mouting on substructure Installation time min / m 2 5-7 4-6 The installation times provided are based on one person. The installation times include: Assembly of PhoneStar boards including board preparation (PhoneStar single-layer). Not taken into account: Material transport to the installation space Assembly of any substructures Insertion of cavity insulation Assembly of covering Note: Approx. 5% waste should be considered in terms of the required materials. Installation instructions Wall 9

B1. PhoneStar cutting and taping 1 2 Measure and mark cutting line Process on stable work surface - adhere to occupational safety! Cut board Jigsaw with ceramic or metal saw blade, circular hand saw with Widia blade and suction. If necessary, refill sand after cutting. 3 4 Mask boards Only mask cut edges with Wolf Tape*. Leave at least 2 cm of the Wolf Tape on the corners. Cover corners Fold the remaining tape on the corners down and press the excess tape on the sides down onto the board surface. 5 6 Push down the tape along the length of the board Press down the Wolf Tape remaining on the side lengthwise. Done. *Warning: PhoneStar boards and Wolf Tape comprise a coordinated system. Liability exclusion in the event that tapes other than Wolf Tape are used. 10 Installation instructions Wall

B2. General instructions for PhoneStar wall mounting Isolation on the subsurface Place a self-adhesive isolation strip along the base of the wall prior to the actual mounting. Isolation strips make it easier to align the first row of PhoneStar boards and also allow for direct mounting of the covering without floor joints. 1 Wall or stud framing 1 2 3 2 PhoneStar 3 Covering 4 4 Isolation strip 5 Subsurface 5 Suitable isolation materials: Self-adhesive foamed rubber or partition wall tapes, thickness 3 / 5 mm, the width must be selected according to the corresponding wall construction incl. covering. Directly press the PhoneStar boards on the flanking walls and ceilings. Work without joints to the greatest extent possible. Board alignment PhoneStar boards are mounted on all walls with and without substructures - horizontally with the length side parallel to the floor. Visible side (side with label) facing into the room during assembly. 1 Visible lable 2 Horizontal PhoneStar board 1 2 Visible side Wall side Side with label Board surface with clearly recognizable corrugation Side without label Board surface flat, no corrugation Installation instructions Wall 11

Board mounting Mount the PhoneStar boards slowly, precisely and one after the other. Begin mounting in the left or right corner of the room. With the first PhoneStar board, it is important to make sure that the board is horizontal, and does not have any height offset, so that all further boards can be fitted cleanly, and without visible joints. Solid or stud wall Correct 1st PhoneStar boards row Incorrect Mount all subsequent rows of PhoneStar boards with an offset of a half board length (or min 10 cm) with regard to the previous row to avoid crossed joints in the PhoneStar layer. 2nd row 3rd row 4th row, etc. General note: PhoneStar sound insulation boards generally require end covering (e.g. plasterboard). It is not possible to plaster, paint, wallpaper, etc., directly onto PhoneStar. 12 Installation instructions Wall

Joint tightness In order to achieve optimal sound insulation results, the vertical and horizontal edges of the PhoneStar boards are masked with Wolf Tape after the PhoneStar boards have been mounted. Wolf Tape In the event that joints form on wall or ceiling connections, the areas must be filled in with Wolf Joint Filler. Wolf Joint Filler Installation instructions Wall 13

B3. Direct mounting on solid walls Direct mounting of the PhoneStar boards in the wall strengthening variation that saves the most space. The Phone- Star boards are mounted on a solid wall with Wolf System Dowels and subsequently covered (e.g. plasterboard). Follow the general mounting instructions found in chapter B2 when mounting PhoneStar boards. Solid wall PhoneStar Covering Wolf System Dowel Wolf System Dowel* Screw connection Adhesive bonding Wall composition An even wall surface that guarantees a complete application of the PhoneStar boards is a requirement for direct mounting of the PhoneStar boards on a solid wall. The Wolf System Dowels must have an anchoring depth in the solid wall of at least 30 mm. If a layer of soft wood fibre is also placed between the solid wall and the PhoneStar boards, then the length of the Wolf System Dowels must take into account the additional layer. Mounting Use 12 Wolf System Dowels in a 3 x 4 pattern for each PhoneStar board. Place the Wolf System Dowels between 2-3 cm from the edge of the board on the external side. Drill diameter: Clay 6 mm Ø Aerated concrete 5 mm Ø Distribution of Wolf System Dowels Note: Do not use rotating rock drilling on honeycomb brick! 12 Wolf System Dowels per PhoneStar board * Note: Minimum anchoring depth in stonework 30 mm. The length of the dowels must take this depth in to account. Only Wolf System Dowels in walls. Ceiling mounting not possible! 14 Installation instructions Wall

Step-by-step direct mounting process: Step 1 lay isolation strips Place a self-adhesive isolation strip on the subsurface along the base of the wall. Material: Partition wall or foamed rubber strips Step 2 Drill hole Drill a hole in the solid wall through the PhoneStar board, which is completely touching the wall. Drill diameter: Clay 6 mm Ø Aerated concrete 5 mm Ø Note: Do not use rotating rock drilling on honeycomb brick! Step 3 Place Wolf System Dowels Hammer the Wolf System Dowels into the drilled holes. Hammer the dowel until it is slightly recessed in the surface of the PhoneStar board. Per PhoneStar board 12 Wolf System Dowels Installation instructions Wall 15

Step-by-step direct mounting process: Step 4 - Cover PhoneStar Generally, the PhoneStar layer is subsequently covered with a layer of plasterboard. In terms of direct mounting, the covering layer requires a minimum thickness of 12.5 mm. The plasterboard is mounted with adhesive and screws. 1 2 1. Gluing. Apply glue along the entire length of the plasterboard to be mounted using multiple beads of Wolf System Glue (every 10 cm). Completely press the plasterboard onto the PhoneStar layer and apply pressure. 2. Screw the plasterboard layer into place with a pattern of approx. 25 cm in the PhoneStar layer, using 3,9 x 22 mm plasterboard screws. 3 4 5 6 1. Wolf System Glue 2. Plasterboard screw Drywall screw gypsum fibre 3,9 x 22 mm PhoneStar - 1 Wolf System Dowel - 2 Covering - 3 Screw connection - 4 Adhesive bonding - 5 Isolation strip - 6 Place the covering on the subsurface directly over the isolation strip. Keep a joint that is approx. 4 mm between the flanking wall and ceiling components. Subsequently seal all connections to the floor, wall and ceiling with Wolf Joint Filler. Edge joints Wolf Joint Filler Covering over the isolation strip 16 Installation instructions Wall

B4. Mounting on substructure & stud wall Mounting on the substructure (wood or metal) describes the process of mounting PhoneStar in the following cases: Substructure on solid wall Isolated Stud Framework Stud wall Note: Follow the general mounting instructions found in chapter B2 when mounting PhoneStar boards. Note: Heavy loads, such as kitchen cupboards, must be mounted onto a framework fitted securely to the substructure, so fit horizontal bars in between the vertical studs in the correct location. Screw connection PhoneStar boards are screwed into the relevant substructure with plasterboard screws. The screws are put into place using 12 screws per PhoneStar board (e.g. 3,9 x 35 mm*) in a 3 x 4 pattern. Wooden substructures require screws with coarse threads, while metal substructures require screws with fine threads. Plasterboard screws: Screw distribution Metal substructure fine thread Wooden substructure coarse thread 12 screws per PhoneStar board Substructure Substructures must be set up with 60 / 62.5 cm contact spacing from the middle of the stud to the middle of the stud, which corresponds to the 120 x 80 or 125 x 62.5 cm PhoneStar board sizes. The installation instructions from the relevant manufacturers must be followed for the stud framing. Cavity insulation Cavities in the wall installation generate resonance and have a negative effect on sound insulation. In order to avoid this, cavities must be lined with insulating material as they form in substructures between the individual studs in the stud framing. Insulation materials: plates made of minerals, mineral wool, hemp or cellulose. Warning: EPS, PU or similar materials are not suitable for use with PhoneStar! Tip: With regard to facing formwork, use to improve the footing of insulating material in stud framing boards - instead of reel material. * The length of the screws must be determined according to the relevant substructure. Installation instructions Wall 17

Substructure on solid wall A substructure can be made on a solid wall in the form of wooden lathing or a metal resilient bars. Place an edge profile on the flanking components. Wooden lathing Resilient bars Stud wall & facing formwork substructure Stud walls and facing formwork can be made out of wooden or metal stud framing. Follow the relevant installation instructions for the setting up and isolation of the stud framing, see manufacturer s instructions. Wooden substructure Metal substructure With regard to stud walls, one- or two-sided PhoneStar mounting in a single- or double-coated design is possible. single double single double One-sided PhoneStar Two-sided PhoneStar 18 Installation instructions Wall

The process of mounting with substructure PhoneStar boards are mounted on a substructure placed directly on the wall in the same way as on substructures for stud walls and stud framing. Below is an example description of a substructure on a solid wall. The process is different for the mounting of PhoneStar and covering with plasterboard on existing stud walls; in this regard, also follow the instructions in chapter B4.1. Step 1 Edge profile Place an edge profile on the flanking components (floor, walls, ceiling). Step 2 Stud framing Mount the substructure vertically within the edge profile. Edge profile Generally, mount the stud framing with a distance of 60/62.5 cm from the middle of the stud to the middle of the stud, based on the PhoneStar board sizes 120 x 80 or 125 x 62.5 cm. Please note The distance (1) between the wall and the middle of the second stud is 60 / 62.5 cm. Then (2) the distance from the middle of the stud to the middle of the stud is 60/62.5 cm. 1 2 Installation instructions Wall 19

Step 3 Insulation Line the cavity that is created between the individual studs of the substructure with an insulating material. Insulating material: Mineral wool or rockwool Soft wood fibre, hemp or cellulose boards Step 4 Lay isolation strip Place a self-adhesive isolation strip along the substructure. Material: Partition wall or foamed rubber strip Step 5 Mount PhoneStar Screw the PhoneStar boards into substructure. 1 2 Plasterboard screws: 3 Metal substructure fine thread Wooden substructure coarse thread 12 screws per board Substructure - 1 PhoneStar - 2 Plasterboard screw - 3 Note: The general mounting instructions in chapter B2 must be followed when mounting PhoneStar boards. 20 Installation instructions Wall

Step 6 Cover PhoneStar Generally, the PhoneStar layer is subsequently covered with a layer of plasterboard. Screw the plasterboard layer into place with Plasterboard screws 5,5 x 38 mm with a pattern of approx. 25 cm in the PhoneStar layer. Important note: The plasterboard screw connection is established in the wall area in the PhoneStar board no screwing through PhoneStar into the substructure. 1 2 3 4 5 Plasterboard screws - 5,5 x 38 mm (Plaster in plaster screw) Pattern approx. 25 cm PhoneStar - 1 Covering - 2 Cavity insulation - 3 Plasterboard screw - 4 Isolation strip - 5 Place the covering on the subsurface directly over the isolation strip. Keep a joint that is approx. 4 mm between the flanking wall and ceiling components. Subsequently seal all connections to the floor, wall and ceiling with Wolf Joint Filler. Edge joints Wolf Joint Filler Covering over the Isolation strip Installation instructions Wall 21

B4.1 Existing stud walls Existing stud walls can also be strengthened at a later time with PhoneStar in either a one-side or two-sided manner with one or more layers of PhoneStar. With regard to stud walls in existing buildings, the Phone- Star boards required a subsequent covering (e.g. plasterboard) with a minimum thickness of 12.5 mm. Existing stud wall The process regarding existing stud walls Step 1 lay isolation strips Place a self-adhesive isolation strip on the subsurface along the base of the wall. Isolation strip Material: Partition wall or foamed rubber strip Top view 22 Installation instructions Wall

Step 2 Mount PhoneStar Screw PhoneStar boards into the existing stud wall. It is necessary to use suitable screws to mount the Phone- Star boards based on the type of existing wall installation. Thus, the PhoneStar boards must be screwed into the substructure in points with a substructure in the wall installation. In areas with no substructure, screws must be used that correspond to the wall material: Screw distribution 12 screws per board Note: The general mounting instructions in chapter B2 must be followed when mounting PhoneStar boards. Mounting of PhoneStar in: 1: Substructure metal* Plasterboard screws (fine thread) 2: Plasterboard* Plasterboard screws (Plaster in plaster screws) 5,5 x 38 mm 1 3: Gypsum fibre* Plasterboard screws (Drywall screws gypsum fibre) 3,9 x 35 mm 2 3 4: Substructure wood* Plasterboard screws (coarse thread) *The type of screw and screw lengths must be suitable for the relevant substructure or wall material. Installation instructions Wall 23

Step 3 Cover PhoneStar board Generally, the PhoneStar layer is subsequently covered with a layer of plasterboard. The covering layer requires a minimum thickness of 12.5 mm. The plasterboard is mounted with adhesive and screws. 1. Gluing. Apply glue along the entire length of the plasterboard to be mounted using multiple beads of Wolf System Glue (every 10 cm). Completely press the plasterboard onto the PhoneStar layer and apply pressure. 2. Screw the plasterboard layer into place with a pattern of approx. 25 cm in the PhoneStar layer, using 3.9 x 22 mm plasterboard screws. 1 2 3 4 5 6 1. Wolf System Glue 2. Plasterboard screw Drywall screw gypsum fibre 3,9 x 22 mm PhoneStar one layer Existing wall - 1 PhoneStar - 2 PhoneStar screw connection - 3 Covering screw connection - 4 Adhesive bonding - 5 Covering - 6 With two-layer PhoneStar, plasterboard is mounted by using plasterboard screws, 5.5 x 38 mm in a pattern of approx. 25 cm, in the PhoneStar layer. Plasterboard screw - 5,5 x 38 mm (Plaster in plaster screw) Pattern approx. 25 cm PhoneStar two-layer 24 Installation instructions Wall

Place the covering on the subsurface directly over the isolation strip. Keep a joint that is approx. 4 mm between the flanking wall and ceiling components. Subsequently seal all connections to the floor, wall and ceiling with Wolf Joint Filler. Edge joint Wolf Joint Filler Covering over the isolation strip Installation instructions Wall 25

Notes Important note: The most up-to-date version of the installation guidelines for PhoneStar applies (see www.wolf-bavaria.eu) Older installation instructions automatically lose their validity. The warranty from Wolf Bavaria GmbH only applies to the flawless condition of our products with adherence to the current installation instructions. All rights reserved, printing and photomechanical and electronic reproduction, - even in extracts - require the express written consent of Wolf Bavaria GmbH, Gutenbergstraße 8, 91560 Heilsbronn, Germany. 26 Installation instructions Wall

Areas of application for PhoneStar boards - Ceiling - Stud wall - Solid wall - Floor Technical consultation and trader directory: www.wolf-bavaria.eu/retailer NEW! Sound Insulation Planning Guide online: www.wolf-bavaria.eu/planning Guide The Sound Insulation Planning Guide is available as a PRINT and WEB version. Installation instructions Wall 27

Sound Insulation Bavaria Installation instructions Wall PhoneStar Sound insulation boards WOLF BAVARIA GmbH Gutenbergstraße 8 D-91560 Heilsbronn Tel.:+49 (0) 9872 95398-0 Fax:+49 (0) 9872 95398-11 www.wolf-bavaria.com info@wolf-bavaria.com Wolf Bavaria is not liable for printing errors. With the publication of this copy, all previous versions lose their validity. Copyright Wolf Bavaria GmbH, 2015. Version 15.05. 2015