NEW TECHNOLOGY FOR INDIRECT THICK SLURRY HEATING SYSTEM

Similar documents
The application of single stream digestion at Votorantim Metais/CBA refinery

IMPROVING RED MUD FLOCCULATION AT AUGHINISH ALUMINA LIMITED

Thermal areas synergy in an alumina refinery

Laboratory Testing of Safety Relief Valves

Relationship Between Liquor Yield, Plant Capacity Increases, and Energy Savings in Alumina Refining

MANAGING ENERGY EFFICIENTLY ENVIRONMENTAL INDUSTRY

PNEUMATIC CONVEYING OF WHEAT FLOUR: SYSTEM OPTIMISATION THROUGH PILOT TESTING. Chandana Ratnayake

PUTTING THE PRESSURE ON ALUMINA FILTRATION WITH ADVANCED VPF TECHNOLOGY

EVAPORATOR SCALE CONTROL USING NON-STICK COATED TUBES

The Continuous Optimization of the Primary Energy Input at AOS A Story of Success

Minerals. WARMAN Centrifugal Slurry Pumps WBV Vertical Cantilever Slurry Sump Pump Series

HORIZONTAL SHELL SIDE FLUIDIZED BED HEAT EXCHANGER, DESIGN CONSIDERATIONS AND EXPERIENCES FROM A PILOT UNIT

IMPROVED FILTRATION AND WASHING OF AL-HYDRATE PRODUCT: COST SAVINGS BY MODERN FILTER DESIGN

Separating Waste from Water

MIXED LIQUOR SCREENING TO PREVENT FOULING IN A MEMBRANE BIOREACTOR WASTEWATER TREATMENT PLANT

AM Technology. Robert Ashe AGITATED CELL REACTORS 16TH PROCESS INTENSIFICATION NETWORK MEETING. 9 th September 2008

Fluid Mechanics, Heat Transfer, Fluid Mechanics Design Project. Production of Ethanol

Custom Systems Built to Exacting Client Specification

Solidification: A New Approach to Zero Liquid Discharge (ZLD) in the SAGD Industry

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management...

STUDY OF A VIETNAM 155 KM BAUXITE SLURRY PIPELINE FROM THE HIGHLANDS TO COAST

Next Generation of Filtration Technology

Manipulating the nature of slurry flows. to overcome production and maintenance challenges. Dr Steve Algie. Consultant, FloCEP Pty Ltd

CHAPTER 2 CULTURE TYPE

GEOTHERMAL POWER PLANTS FOR MEDIUM AND HIGH TEMPERATURE STEAM AND AN OVERVIEW OF WELLHEAD POWER PLANTS

A new pipeline cleaning technology: Hydraulically Activated Power Pigging (HAPP TM )

Fluid Mechanics, Heat Transfer, Thermodynamics. Design Project. Production of Ammonia

FLUIDIZED BED HEAT EXCHANGERS FOR THE EVAPORATION OF WASTE WATERS: DESIGN ADVANTAGES AND OPERATIONAL EXPERIENCES.

CAUSTIC RECOVERY USING MEMBRANE FILTRATION

PROVISIONAL PATENT APPLICATION NS306. Method for Establishing Self-Lubricated Flow of Bitumen Froth or Heavy Oil in a Pipeline

SAM IL INDUSTRY CO.,LTD. IN THIS CHAPTER - 5

Keeping the RO Membranes of the Future Continuously Clean. Author: Boris Liberman, Ph.D. VP CTO IDE Technologies Ltd

Hydroelectric power plants

APPLICATION AND BENEFITS OF ADVANCED CONTROL TO ALUMINA REFINING

A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.

Biomass ash deposition, erosion and corrosion processes. W R Livingston IEA Task 32/Thermalnet Workshop Glasgow September 2006

is a paradigm shift in produced water treatment technology occurring at SAGD facilities?

Fluid Mechanics, Heat Transfer, Thermodynamics Design Project. Production of Ethylbenzene

Two-stage classification in one unit

Improved Efficiency of Solid Trap Installed in Brine Injection Pipeline of Leyte Geothermal Production Field, Philippines

WYATT Orifice flow PrOducTs

Measurement of Two Phase Flows in Geothermal Pipelines Using Load-Cells: Field Trial Results

Recent developments in spiral separator design include 3 mineral models; EP, HC and MG7S; and one coal model, the LD7C.

SOLID-LIQUID SEPARATION TECHNOLOGY FOR REMOVING CONTAMINANT FINES FROM WATER SCRUBBING, CLARIFIER EFFLUENTS AND GREY WATER PAPER NUMBER

Proceedings 1 st International Conference on New Forming Technology, Sept , Harbin, China, pp

Cork Institute of Technology. Summer 2008 Process Plant Design (Time: 3 Hours)

EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET

Tracer Dilution Measurements for Two-Phase Geothermal Production: Comparative Testing and Operating Experience

On-line corrosion mapping of industrial plant using advanced electrical resistance techniques

Comparing Evaporative Technologies for the Recycling of Produced Waters

REDUCING DRAG TO BOOST CAPACITY

Mobile Nitrogen Vaporizer Skid

UPGRADING OF A CONVENTIONAL PRECIPITATION LAYOUT IN EURALLUMINA REFINERY. Teodosi, A. and Candeloro, N. Eurallumina SpA, Portoscuso, Italy

On-line determination of particle size and concentration (solids and oil) using ViPA Analyser - A way forward to control sub sea separators

The following sub-systems are provided and the integration of these is described below:

Design Mode Analysis of Reheaters in Nuclear Steam Secondary Cycles

CF100 BAND SCREENS REDUCE MAINTENANCE COSTS & DOWNTIME... INCREASE CAPTURE RATIO & EFFICIENCY

COMBINED EXPERIMENTAL AND SIMULATION (CFD) ANALYSIS ON PERFORMANCE OF A HORIZONTAL TUBE REACTOR USED TO PRODUCE CARBON NANOTUBES

Pitot Tubes and Industrial DP Transmitters (Optional Exercise)

FLASH ROASTING OF SULPHIDE CONCENTRATES AND LEACH RESIDUES USING A TORBED* REACTOR

Diaphragm valve head loss coefficients for coarse particles transported in a non-newtonian carrier fluid

Design of Pneumatic Conveying Systems

FLSmidth Dorr-Oliver Eimco Flotation Technology. Superior Metallurgy Higher Availability

Design and Operation of Pan Filters at the Physical Cake Moisture Limit

edart Samplers Issue 1.0, November 2013 Unique design Long life Compact Easy to maintain Corrosion resistant Cost effective

Specific speed and impeller diameter

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

A holistic approach in the analysis of and turn-around strategies for municipal water supply systems The perspectives of a financier

Modular Oil & Gas Equipment Onshore & Offshore

FLOTATION CONTROL & OPTIMISATION

Inland Technologies Inc

Flow Conditioning Why, What, When and Where. Gas Flow Conditioning Why, What, When and Where

Flotation machine RCS TM 300. New flotation concept

HEAVY INDUSTRY PLANT WASTEWATER TREATMENT, RECOVERY AND RECYCLE USING THREE MEMBRANE CONFIGURATIONS IN COMBINATION WITH AEROBIC TREATMENT A CASE STUDY

d&wr desalination & WATER REUSE

Page 1 of 5. Sonar Technology: More than Just a Flow Meter - Leveraging Dual Measurement Capability for Enhanced Value in Industrial Processes

OsmoBC Integrated Membrane Systems

Effect of bauxite characteristics and process conditions on control of silica and phosphate in Bayer liquor

Available online at ScienceDirect. Procedia Engineering 102 (2015 )

DEVELOPMENT OF RADIOMETRIC METHODS FOR OPTIMIZATION OF PHOSPHATE TRANSPORT PROCESS BY ''SLURRY PIPE''

A Hands-On Guide to Ultrafiltration/Diafiltration Optimization using Pellicon Cassettes

Heat Transfer Theory. Jennie Borgström

Dr. J. Wolters. FZJ-ZAT-379 January Forschungszentrum Jülich GmbH, FZJ

AN INTRUSIVE METHOD FOR FILM THICKNESS MEASUREMENT ON SMOOTH HORIZONTAL TUBES FOR SUBCOOLED WATER

WINERY ENERGY SAVER TOOLKIT SUPPLIER CHECKLIST COMPRESSED AIR

OIL TECHNOLOGY PORTFOLIO

Abstract. 1 Introduction. Golder Associates Ltd, Canada

HX Performance Testing

Final results. The following units are part of EfficientHeat solution:

HOW TO SELECT BEST MEG RECOVERY UNIT s CONFIGURATION?

Stabilisation/Solidification of Manufactured Gas Plant Wastes: Pilot Test Study Part 2

RESERVOIR MIXING WHAT S REALLY GOING ON INSIDE YOUR WATER SUPPLY RESERVOIR? Danny Roberts & Scott Bradshaw. Port Macquarie-Hastings Council

Estimation of Boil-off-Gas BOG from Refrigerated Vessels in Liquefied Natural Gas Plant

PRIORITISATION OF WASTEWATER PUMP STATION UPGRADES USING ASSET MANAGEMENT PRACTICE

Investigation into Sand Deposition and Transportation in Multiphase Pipelines

A Hands-On Guide to Ultrafiltration/ Diafiltration Optimization using Pellicon Cassettes

PRESSURE WAVE ANALYSIS STREAMLINES PIPELINE PIGGING. Thomas Redares and Neil Stewart, Halliburton Pipeline & Process Services

LASERTUBE LT14 - LT24

Ultrafiltration Testing Report

Copyright is owned by the Author of the thesis. Permission is given for a copy to be downloaded by an individual for the purpose of research and

Transcription:

NEW TECHNOLOGY FOR INDIRECT THICK SLURRY HEATING SYSTEM Edwards M *, Kelly R and DeBoer D Hatch Associates Ltd, Perth, WA, Australia Abstract In the pre-desilication of Bayer bauxite slurries, the first step is to heat the slurry to ~100 C. Direct steam injection adds unwanted dilution that has to be removed by additional evaporation, resulting in capital and operating cost impacts, and production losses. With indirect heating, the nature of thick, viscous slurries can lead to accelerated scaling on tube walls and rapid reduction in heat transfer resulting in short operating cycles. Blockages and/or excess scale also create high heater cleaning maintenance. Often these fundamental issues render indirect heating uneconomic against direct steam injection. This paper describes a new technology developed and patented by Hatch for Indirect Heating of Thick Slurry, which overcomes all of the issues above. This technology has been successfully trialled using a full size pilot plant and the first commercial scale project is in operation with a second commercial scale project in progress. The safety, technical, operational and cost advantages are discussed. 1. Introduction Process efficiency requirements normally dictate that bauxite slurry be ground and desilicated at as high a slurry density as can be practically handled by the slurry pumping and agitation equipment. Typically slurry density ranges from around 35% by weight to as high as 60% by weight, depending on the bauxite. These slurries are termed thick slurries in this paper. There are two basic modes of heating thick slurries in the alumina industry, direct heating and indirect heating. For direct heating, steam or vapour is injected directly into the slurry. This form of heating is often used because the equipment required is simple and avoids a number of serious problems associated with the more complex heat transfer equipment utilised in indirect heating of thick, viscous slurries. These issues apply equally to thinner slurries such as in Digestion. For indirect heating, heat exchangers with relatively complex piping, instrumentation, controls and maintenance are required to keep the heating medium separate from the slurry stream. This paper outlines innovations that address a number of fundamental issues associated with successfully designing and operating an indirect thick slurry heating system, namely: Controlling scaling rate Maintaining high Heat Transfer Coefficient (HTC) Long term heater durability and wear resistance Increased heater cleaning cycle Ease of cleaning and maintenance. The mechanical design of the heater is combined with an integrated instrument control system that inhibits scaling and maximises heater performance and life. The technology has been successfully trialled at an alumina refinery in Western Australia in 2005 and commercially installed at a Queensland refinery in 2007. These innovations are patent protected [1, 2]. 1.1 Thick Slurry Heating Issues The Bayer process stream is a recirculating flow that must be maintained at a certain caustic concentration. A major disadvantage of direct heating is that it adds steam to the process stream and thereby dilutes it. Any water added to the process must be removed by expensive forced evaporation in other parts of the Bayer process. Dilution also reduces the production capacity of the plant where flow limitations exist. Indirect heating is therefore the preferred method of heating provided technical and maintenance issues can be overcome. The main problem to date associated with indirect thick slurry heating has been the poor heat transfer coefficients that are obtained leading to large heat transfer areas and high capital costs. Thick slurry heating is often unreliable as tubes tend to scale and wear rapidly, requiring frequent cleaning and/or replacement. The reasons for this are: Firstly, thick bauxite slurries typically containing 35 60% solids by weight exhibit highly non-newtonian behaviour. They are extremely viscous. Flow within heater tubes is outside a simple laminar regime and tends towards plug flow. There is little turbulence and consequently little mixing between the heated boundary layer and the bulk of the flow, leading to an increase in slurry temperature along the tube wall relative to the bulk volume contained within the tube. This reduces the effective temperature difference between the heating medium and the fluid being heated and is a major contributing factor to the poor heat transfer achieved in indirect thick slurry heating to date. Secondly, a major factor is the pressure regime at which typical thick slurry heating installations operate. The slurry is usually discharged at or near the atmospheric boiling point to a slurry storage or desilication tank. Pump heads are therefore relatively low. Temperature of the heating medium (generally steam) outside the tubes is well above the boiling point of the slurry, and the tendency for the heat to concentrate in the boundary layer at the tube wall makes it highly likely that this layer exceeds boiling point and bakes within the tubes, increasing scaling rate. Thirdly, tube wall scaling has a dramatic effect on decreasing the HTC of the heater. Scale thermal conductivity is very low so minimisation of scale growth is particularly important. Techniques on controlling scale growth have not been incorporated in traditional designs. Finally, an additional problem with indirect slurry heating by means of traditional shell and tube heaters has been rapid wear at the tube entrance due to the high percentage of solids. Where standard gauge heater tubes are used, eroded tubes must be frequently replaced. This rapid wear is to a large extent due to the profile of the entry, which is normally square. A square entry results in concentrated wear at the entry itself and causes considerably higher than 56 Proceedings of the 8th International Alumina Quality Workshop 2008

average velocities a short distance downstream from the entry, where the incoming stream of slurry contracts. 1.2 Thick Slurry Heating Design Innovations (Figure 1) The process design innovations utilise 3 key principles: 1. Maintain the Reynolds number of flow through the tubes as high as practicable, in order to keep the flow regime in the turbulent regime and maintain a reasonable level of natural mixing by some means of frequent in-line mixing, or by utilising short tubes (more channel sections), in order to average the slurry temperature. 2. Control slurry pressure relative to the temperature of the heating medium to ensure slurry cannot boil within the tubes, eliminating slurry baking on the tubes. 3. Optimise tube velocity as high as possible (balance with tube wear), reduce heat flux (balance with heating area required) and ensure ongoing pressure control (balance with supply pump head/power) to reduce scale growth. Figure 2. Basic Plan Schematic of Heating System Figure 1. Basic Elevation Schematic of Heating System In terms of mechanical design, the problem of tube entrance wear and tube replacement is addressed by utilising a wear plate and pipe (instead of gauge heater tube) for heater construction: By selecting a pipe diameter somewhat larger than standard heat exchanger tubes, Reynolds number can be increased and turbulence in the slurry enhanced to some degree. Pipe has the advantage of a greater wall thickness well in excess of the thickness required for pressure containment and therefore provides more material for potential erosion. Larger diameter, thick walled pipes minimise tube blockages and prevent damage when mechanical cleaning. A wear plate has sufficient thickness to allow entries to be rounded at the tube plate. Such rounding reduces both the concentration of velocity at the edge of the entry and at the downstream contraction of flow. High wear and high downstream velocities are thereby abated. 1.3 Thick Slurry Heating Construction Innovations (Figure 2) Apart from design considerations, resolving maintenance issues is also critical to making a heating system viable: The new heaters are single pass for simplicity, ease of construction and cleaning. While this results in a larger number of heaters than conventional shell and tube heating systems, this system is devised as a modular set of simple heater units. Additional duty, any changes to process conditions that reduce the heater performance, or even under-designed systems do not require heaters to be replaced as an additional heater can be readily added to make up the shortfall in duty. The heaters utilise standard size pipes and fittings to fabricate the shell and tubes. Combined with a smaller shell size this creates the opportunity to construct modular units at low cost off site. Modular units can be pre-assembled and shipped to site from the fabrication shop as ready-to-install, skid-mounted units complete with interconnecting pipe work, supporting structure, instrumentation and valves. The advantage of modular units depends on whether a horizontal or vertical orientation layout of the heaters is used. Heaters can be arranged in the horizontal or vertical plane depending on footprint restrictions. Horizontal is preferred as it simplifies access, maintenance, piping layouts and reduces potential for tube blockages. The combination of the above design attributes results in a significantly higher sustainable HTC together with improved reliability and robustness, making these indirect heaters economically viable for replacing direct steam injection heaters. 2. Full Scale Pilot Plant Trial Overview As part of a refinery expansion study, economic benefits were identified for installing indirect heating for the thick bauxite slurry feed pumped from the grinding mills to the pre-desilication tanks. The existing process used direct steam injection. New indirect heaters would remove significant dilution from the process and allow bauxite slurry to be heated to a higher temperature, further improving pre-desilication. This could eliminate the requirement to install an additional Slurry Storage Tank and allow decommissioning of an Evaporation Unit, significantly enhancing project economics. 2.1 Trial Description Three heaters were designed and supplied for installation of a full scale pilot plant to take full plant slurry flow for 1 of 5 units. Bauxite slurry properties are summarised in Table I. For the project to prove viable, the heaters had to maintain above 550 W/m 2 C for at least one month with heater cleaning turnaround being less than 3 4 days. Once the pilot plant was constructed, performance data on the heaters were collected, including HTC, temperature pick up, pressure and steam consumption. This provided data for the design of a full scale heating facility to replace the existing direct steam heaters. Proceedings of the 8th International Alumina Quality Workshop 2008 57

Table I. Trial Process Data Parameter Units Trial Value Volumetric Flow m 3 /h 570-730 Solids Concentration Weight % 44-46 Caustic Concentration g/l Na 2 CO 3 210 Slurry Density kg/m 3 1650-1780 Slurry Feed Temperature C 70-75 Slurry Exit Temperature C 90-100 Heater Shell Size NB 600 After 9 weeks operation and despite the heaters being repeatedly subjected to undesirable process conditions due to plant upsets, HTC was still stable at 1500 1550 W/m 2 C (Graph I). HTC regularly recovered after the heaters were left full of slurry during extended shutdowns from other plant problems, demonstrating that the simplified design allows the heater to re-suspend settled solids of its own accord when draining is not done or flow interruptions occur. When heaters were taken offline and inspected after the 9 weeks operation there was only a thin layer of scale observed in the tubes that was quickly and effectively removed with highpressure water jet cleaning. Figure 3. Trial Process Schematic 2.2 Technical Challenges and Sensitivity to Process Parameters Design of the new bauxite slurry heating system addresses technical challenges associated with key process parameters that are important in the design but difficult to accurately establish: Expected heater cleaning cycle required Scale Thermal Conductivity Shell Side Fouling Factor Rate of decline of HTC or Scaling Rate Bauxite characteristics (including slurry rheology) Graph 1. Full Scale Trial Heat Transfer Coefficient Refinery 1 Based on on-site observations of the cleaning process, it was estimated the three heaters could all be cleaned within 3 4 hours. The reduced scale thickness may mean only a high velocity liquor flush on occasions, a major improvement on existing designs. Note that due to the high HTC maintained, cleaning was not necessary but performed as a trial only, in fact it is more beneficial to leave a slight scale film on the tubes as this will protect the tube wall from long term wear. If this information is not available or there is concern over the accuracy or relevance of the data that are available, data can be extrapolated from other sources to develop values suitable for design. However, this approach introduces a degree of uncertainty to the design. While use of actual data is preferred, it is also recognised that measurement of some of the above parameters in laboratory test work or even existing plant operations has limitations. This uncertainty can lead to a belief that pilot testing is necessary. The modular component of the new heating system design enables uncertainty in parameters to be managed in a cost effective manner by allowing additional heaters to be incorporated into the design or added at a later stage. Due to the simplicity of the heaters, the cost of doing this is in the order of USD 100 150K per heater, which is much lower than the cost of a pilot trial. 58 Proceedings of the 8th International Alumina Quality Workshop 2008

The following sensitivity analysis shows how uncertainty in the parameters can be assessed to enable a manageable level of risk to be selected in design. A target temperature of 105 C and 12 weeks cleaning cycle were selected as the base case. Scale Thickness Scale thickness is proportional to scaling rate, hence the time between cleaning cycles is related to the change in scaling rate: To maintain 105 C, a 20% increase in scaling rate reduces life from 12 to 10 weeks, a 17% decrease in cleaning cycle. To maintain 12 weeks life, a 20% increase in scaling rate reduces exit temperature from 105 C to 102.5 C. Slurry Rheology Accuracy of slurry rheology values can be expected to vary by 50 100% due to the difficulty of measurement in the laboratory, although the impact on design will be significantly less: To maintain 105 C, a 100% increase in slurry viscosity from base value only reduces life from 12 to 10.4 weeks, a 13% decrease in cleaning cycle. To maintain 12 weeks life, a 100% increase in slurry viscosity from base value only reduces exit temperature from 105 C to 103 C. Scale Thermal Conductivity (Base value 1.0 W/m 2 C) This potentially has the greatest impact as there is a wide range of values reported for different bauxites and refineries: To maintain 105 C, a scale conductivity value of 0.3 W/ m 2 C reduces life from 12 weeks to 3 weeks, a 75% decrease in cleaning cycle. To maintain 105 C, a conductivity value of 1.73 W/m 2 C increases life from 12 weeks to 23.2 weeks, an increase of 93% in cleaning cycle. To maintain 12 weeks life, a scale conductivity value of 0.3 W/m 2 C reduces exit temperature from 105 C to 85.1 C, a decrease of 20 C. Shell Side Fouling The quality of steam should be clean to prevent scaling inside the shell. Fouling factor can be predicted accurately and will not change significantly over time provided steam quality is maintained: To maintain 105 C, a 100% increase in shell side fouling only decreases cleaning cycle from 12 weeks to 10 weeks, a 17% decrease in cleaning cycle. To maintain 12 weeks life, a 100% increase in shell side fouling only reduces end temperature from 105 C to 102.7 C. The example analysis above demonstrates that process parameters will have varying degrees of effect on the heating performance. Some will counteract the effect of others. Except for scale thermal conductivity, even relatively large variations in expected values of key parameters generally result in only small variations in heating system design, that is, a variation of one or two heaters which can be added following commissioning if it is found that the design parameters used were not fully valid. This is a key benefit of the new modular design. Since scale thermal conductivity is the main factor that can have a significant impact on number of heaters or life cycle, it is preferable to establish at least an approximate value from laboratory tests to reduce technical risk. Samples taken from existing desilication or digestion heating equipment utilising the bauxite under consideration can be measured. The technical challenges can be overcome when the issues and relevance to the system performance is properly understood. 2.4 Methodology for Design Each type of bauxite and scale exhibit different properties under different process conditions. The conservative way to obtain definitive data for actual slurries to be heated is to conduct pilot plant trials or undertake bench-scale testing. While bench-scale testing of thick slurries may be less costly, accuracy of the data obtained may not add any technical value. As found in the project outlined above, neither the cost nor time delays associated with plant trials or bench-scale testing are generally considered justified given the alternative approach utilised below. A design methodology has been developed that generates information from existing plant data and other sources to perform design without the need for pilot testing: Scaling Rate. HTC curves are generated and scaling rates estimated from plant data and used to estimate the life cycle of the Thick Slurry Heaters. While this method is subject to inaccuracy, it provides some basis for estimation in the absence of a pilot trial. Slurry Rheology. Shear stress shear rate rheograms are developed. Scale Thermal Conductivity. Laboratory measurements are made and compared to values of the in-house database. General heat exchanger design principles are well documented [3,4,5] and can be applied to optimise the performance. The relative benefits of design enhancements versus additional capital costs required should be considered to ensure efficient and effective use of capital spending. 3. 1 st Full Scale Facility Installation Results A full scale design for heating full plant flow for a new predesilication facility was recently commissioned in Australia. The heating system consists of 10 heaters, 8 duty and 2 spares. Since there is only one incoming feed, piping layout allowed any pair of heaters to be taken out of service for cleaning. Initially the design was restricted to 85 C rather than 105 C due to process and equipment concerns in Digestion. With the modular design, this allowed the number of heaters online to be adjusted to suit the much lower duty. The system was commissioned in late 2007 with relative ease and site personnel have indicated that operations and maintenance found the system easy to operate and clean. The HTC graph for the heating system performance is given in Graph 2. This plant slurry exhibits a more viscous nature, significantly higher silica content and lower tube velocities than the slurry used in the Pilot Plant Trial resulting in a lower design HTC target of ~840 W/m 2 C. This graph indicates performance is close to target. Importantly, it was discovered on inspection that there was little or no tube scale and the performance drop off was due to tube blockages, some due to large pieces of scale (50mm+) from an unknown source. The lack of tube scale again indicates the technology to be sound. Monitoring is ongoing to optimise the performances and was in progress during the writing of this paper. 3.1 Investment Payback Period Payback for the capital investment required to install the new system to replace existing direct steam injection has been analysed for a number of refinery sizes and configurations using typical energy costs. The analyses indicated: Proceedings of the 8th International Alumina Quality Workshop 2008 59

Capital costs ranged from USD 2.2 3.7 million Annual energy savings ranged from USD 2.0 5.7 million Payback ranged from 8 14 months. 3.2 Other Applications Application of this heating system was originally designed to resolve the problems associated with indirect heating of thick bauxite slurries. However, the design can potentially be applied to any industry heating thick or thin slurries or liquor where scaling occurs. For example, alumina hydrate precipitator interstage coolers are typically plate heat exchangers. They have a A successful indirect heating system is dependent on resolving the process and design parameters, mechanical design and maintenance issues associated with this type of heater. The new design has been developed to address all these aspects. In the absence of accurate process data, the modular design reduces technical risk and hence reduces capital risk and potentially eliminates the need for expensive and time-consuming pilot testing. The savings resulting from achieving the benefits from the new indirect heating system earlier by avoiding project delays due to pilot testing more than outweigh the cost of including or adding additional heaters later if found to be required Graph 2: Full Scale Project Heat Transfer Coefficient Refinery 2 high volume and low thermal exchange of typically only 5 10 C per heater. These heaters are notorious for high scaling and blocking issues and high maintenance to keep clean. The application of this heating system can be extended to several larger heaters that offer a more robust and easily maintainable heating system. The single pass tubes will be less susceptible to blockages and easier to clean. The control system should also reduce the scaling rate, extending the cleaning cycle. By applying similar design principles, the advantages of this heating system can be translated to many different applications. 4. Conclusions Providing indirect pre-heating of slurry prior to Digestion and elimination of dilution from the process generally has a significant cost saving for any refinery, and particularly for a refinery with limited evaporation and plant capacity. The simplicity of the mechanical design addresses the maintenance and mechanical issues. The integrated control system and backpressure control system addresses the scaling problem. The pilot trial and new facility installation to date has successfully proven the technology is sound, and further commercial installations will establish the robustness of the design for a range of bauxites and process conditions. The commercial installations will also provide additional information on the potential application of this technology to any thick or thin mineral slurry heating process in alumina refineries and other industries. References 1. International Publication Number WO 2005/119154 A1 (2005), Thick Slurry Heating System. 2. D Deboer, M Edwards, R Kelly, P McIntosh (TMS 2007), New Technology for Indirect Thick Slurry Heating. 3. D.A. Donohue (1949), Heat Transfer and Pressure Drop in Heat Exchangers, Industrial and Engineering Chemistry Vol 41, No 11. 4. D.Q. Kern (1965), Process Heat Transfer, McGraw-Hill. 5. Tubular Exchanger Manufacturers Association, Inc (1999), Standards of the Tubular Exchanger Manufacturers Association, Eighth Edition. 60 Proceedings of the 8th International Alumina Quality Workshop 2008