HyperCel STAR AX Ion Exchange Sorbent

Similar documents
HyperCel STAR AX Ion Exchange Sorbent

Q and S HyperCel Sorbents

Use of ScreenExpert RoboColumns u

ScreenExpert RoboColumn

Application Note USD Purification of Mouse IgM from Cell Culture Supernatant by Cation Exchange Chromatography on CM Ceramic HyperD F Sorbent

Application Note USD Microcarrier Mixing in PadReactor Mini Bioreactor

Application Note USD 3086 (1) Animal Component-Free Star-Plus Microcarriers for Adherent Mammalian Cell Culture

Application Note USD3011. Influenza Virus Production with Adherent VERO Cells in PadReactor Mini Bioreactor

Harvesting Technology Guide for mab Processes. Accelerated process development through the identification of optimal platform solutions

Cadence Single-pass TFF Coupled with Chromatography Steps Enables Continuous Bioprocessing while Reducing Processing Times and Volumes

Instructions For Use USD3144. Pall Microdisc Filter Capsules with Pegasus Protect Prefilter Membrane

Scalability of Cadence Inline Concentrator Modules for Bovine IgG Processing

Chemical Compatibility of the Pall QPoint TM Filter Capsule - Rose Outlet with Systemic Water Treatments

In most downstream purification

Protein A Ceramic HyperD F Affinity Chromatography Sorbent

Nuvia HR-S Strong Cation Exchange Media Instruction Manual

TOYOPEARL GigaCap Series

BIOSEPRA MBI HYPERCEL. Mixed-mode sorbent for direct capture of antibodies.

Cadence Virus Inactivation System

Efficient Multi-Well Protein Purification Strategies

Table 1, Performance characteristics of Cellufine SPA-HC

Purification of Recombinant Proteins on Nuvia TM cprime TM Hydrophobic Cation Exchange Media: A Simple Approach to Method Development

Nuvia cprime Hydrophobic Cation Exchange Media

Polishing of monoclonal antibodies using Capto S ImpAct

Convenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF

Capto S, Capto Q, and Capto DEAE

BabyBio S BabyBio Q BabyBio DEAE

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

WorkBeads Protein A INSTRUCTIONS IN

Alkali Resistant and Optimized Ligand for High Capacity Surface Modified Base Bead for High Purity Semi-rigid Bead for High Productivity

Alkali Resistant and Optimized Ligand for High Capacity Surface Modified Base Bead for High Purity Semi-rigid Bead for High Productivity

Econo-Pac Serum IgG Purification Kit and Econo-Pac Serum IgG Purification Columns Instruction Manual Catalog Numbers and

The Eshmuno Chromatography Family of Resins

DexS-HbP. Technical Note Heparin Mimetic Affinity. Model Protein adsorption to Cellufine MAX DexS-HbP resin

Capto * Blue and Capto Blue (high sub)

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

Application Note USD Pall SoloHill Animal Protein-Free Microcarriers for Dengue Virus Production

Capto Q. GE Healthcare. Media characteristics. High flow rates and low backpressure in large-scale columns

Purification of oligonucleotides by anion exchange chromatography

Capto Blue and Capto Blue (high sub)

GORE. Protein Capture Devices. Operating Instructions Contents. Product Description Device Characteristics... 2 General Handling...

Ion Exchange Chromatography Media. Cellufine IEX. Technical Data Sheet

Instructions For Use. Mustang Q, S and E Single-Use Capsules. Assembly and Installation Procedures. For Part Numbers:

Protein A Resins. Modern, Advanced High-Flow, Highly Cross-Linked Agarose Resins For Improved Process Economics.

Capto Q Capto ViralQ Capto S

BioPro SmartSep. Benefits of using BioPro SmartSep. Product information

Phenyl Membrane Adsorber for Bioprocessing

[ Care and Use Manual ] Waters AccellPlus QMA and CM Bulk Media. I. calculating bulk media needs. II. packed column use. IIi.

MabSelect SuRe. GE Healthcare. Alkali-stabilized protein A-derived medium for capture of monoclonal antibodies. High stability in alkaline conditions

Chromatography Column Performance and Data Analysis Success Guide. Hints and Tips for Better Purifications

Capture of human single-chain Fv (scfv) fusion protein on Capto L affinity medium

Capto adhere ImpRes. GE Healthcare Life Sciences. Polishing medium for MAb platform processes

Affi-Gel Protein A MAPS II Kit Instruction Manual

Bio-Works products. Research & Laboratory Process Development Bioprocess Production

Fast protein separations with ion exchange columns

Mimetic Blue Affinity Adsorbents Mimetic Blue 1 P6XL, Mimetic Blue SA P6XL Mimetic Blue SA HL P6XL, Mimetic Blue ELISA Kit

Capacity and performance of MabSelect PrismA protein A chromatography resin

Phenyl Membrane Adsorber for Bioprocessing

Cellufine MAX HIC Butyl, Phenyl Technical Data Sheet

HiScreen prepacked columns

Capture of mouse monoclonal antibodies

Rapid Microbiology System

Single-use bioreactor for process intensification

1. Connect the column to the chromatography system, syringe or pump.

Column for High Performance,High-Binding Capacity Ion Exchange Chromatography:TSKgel SuperQ-5PW and Its Applications

Ab SpinTrap Ab Buffer Kit

MabSelect Xtra. GE Healthcare. Recombinant protein A-based, high-capacity affinity medium. Medium characteristics Description

Column Packing of Cellufine A-500 ion exchange chromatography resin

MabSelect Xtra * GE Healthcare Life Sciences. Medium characteristics Description. MabSelect family

A novel approach to Protein A capture chromatography to help decrease cost of clinical manufacturing and reduce supply chain risk

Allegro CM150 Single-Use Tangential Flow Filtration System

Next Generation Zirconia-Based Antibody Purification Media

Nuvia S and Q High-Capacity Ion Exchange Media Instruction Manual

USD Pall SUPRAdisc and SUPRAcap Modules with Seitz AKS Filter Media - The Better Choice

TechnicalNote. BAKERBOND Multimode Ion Exchange Chromatography Media. Introduction. BAKERBOND PolyPEI

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

The practical task of monoclonal IgG purification with CHT TM ceramic hydroxyapatite

Improving IEX Throughput and Performance with Differentiated Chromatography Sorbents

The above media is designed to capture antibodies or other molecules of similar size.

New Core-Shell Technology

UNOsphere SUPrA Affinity Chromatography Media

Protein purification and bioprocessing MINIATURE PARALLEL AUTOMATED

YMC-BioPro NEW. porous and nonporous IEX columns. For the analysis and separation of peptides, proteins and biomolecules

NIRO Kieselguhr, Sheet and Combi Filter

SOURCE 15Q, SOURCE 15S, and prepacked column formats

ProteoMiner Protein Enrichment Technology

MabSelect PrismA. gelifesciences.com/bioprocess

columns PepSwift and ProSwift Capillary Monolithic Reversed-Phase Columns

Application Note USD 2975 (1) Pall SoloHill Microcarriers in the PadReactor Single-Use Bioreactor

Sartobind IEX nano 3 ml

UNOsphere Q & S Ion Exchange Media. Instruction Manual ...

Kleenpak HT Sterile Connectors Extension of the Autoclave Cycle Sterilization Time

Separation of Monoclonal Antibodies Using TSKgel HPLC Columns

HiTrap Capto adhere, 1 ml and 5 ml

Immobilized Protein G

Capto S ImpAct. Chromatography medium characteristics Ionic groups and base matrix. gelifesciences.com

An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite

Xpansion Multiplate Bioreactor System

MAbPurix TM Protein A Affinity Chromatography Resin media and column

Transcription:

USD 2831(2) HyperCel STAR AX Ion Exchange Sorbent Salt Tolerant Advanced Recovery Anion Exchange Chromatography Sorbent An industry-scalable anion exchange chromatography sorbent designed for high productivity protein capture and impurity removal at moderate or higher salt conductivity (2 to 1 ms/cm), typical of undiluted biological feedstocks (i.e., mammalian cell culture supernatants, E. coli feedstock, plasma, others ). Filtration. Separation. Solution.SM

HyperCel STAR AX sorbent is manufactured at large scale and meets the needs of industrial users and regulatory authorities. A Regulatory Support File (RSF) is available to assist users in the development of validation procedures. This sorbent offers: High dynamic binding capacity (DBC) at short residence time (2 minutes or lower) Direct capture of protein or impurity removal from undiluted feedstock at moderate or high conductivity Excellent flow rate properties for fast feedstock processing Distinctive selectivity, consistent in a broad conductivity range (2 1 ms/cm) Enhanced process economics HyperCel STAR AX sorbent is composed of a rigid cellulose matrix that has excellent flow properties and generates low backpressure, compatible with the needs of manufacturingscale protein production. The sorbent is available in a variety of packaging configurations, as AcroPrep ScreenExpert 96-well Plates designed for early screening of resins suitable for protein purification, and also as convenient 1 ml and ml PRC prepacked columns designed for fast method optimization, selectivity screening or small preparative work. HyperCel STAR AX sorbent is supplied as a slurry/suspension in 1 M NaCl containing % (v/v) ethanol or as a moist cake for process-scale applications (the moist cake sorbent facilitates the sorbent transfer, avoiding the agitation and suspension of large material volumes). HyperCel STAR AX sorbent has a chemical stability that ensures simple clean-in-place (CIP) and storage. For standard CIP,. to 1 M NaOH treatment is recommended, while long-term storage in to mm NaOH is possible. Table 1 Main Properties Average particle size Ion exchange ligand Dynamic binding capacity 1 Typical operating range of feedstock conductivity Recommended cleaning conditions 2 8 μm Primary amine > mg BSA/mL within ph range 7. 8. and conductivity 1 ms/cm 2 1 ms/cm 1 M NaOH 1. Determined using a mg/ml BSA in 2 mm Tris-HCl,.1 M NaCl at 2 minute residence time. 2. Injection of column volumes (CV) of. 1 M NaOH, 1 hour contact time. HyperCel STAR AX sorbent is very easy to pack and unpack in laboratory, pilot and production-scale columns, and shows excellent flow properties, compatible with the requirements of advanced production processes. The sorbent can be packed in standard inexpensive buffers. For example, a mm I.D. x 1 mm height column packed in a mm NaCl buffer can be operated at less than 1. bar (22 psi) backpressure (Figure 1). Packing performance is consistent from laboratory to large scale ( mm I.D.) columns, Typical values of N/m > plates and asymmetry factors (AF) are: 1.<AF<1.. Figure 1 Pressure vs. Flow Rate of HyperCel STAR AX Sorbent 1.8 Pressure (bar).6..2 6 Linear velocity (cm/hr) Column: mm I.D. x 1 mm bed height. Packing Buffer: mm NaCl 2

Features and Benefits High Dynamic Binding Capacity in Broad Conductivity Operating Conditions: Avoids Feedstock Dilution and Streamlines Downstream Processing Figure 2 Dynamic Binding Capacity vs. Residence Time as a Function of ph and Conductivity of HyperCel STAR AX Sorbent Conductivity 18 16 1 12 8 6 Residence Time = 1 min Residence Time = 2. min Residence Time = min 6 6 6 18 8 8 18 8 16 16 1 1 1 1 1 1 12 1 12 1 16 16 16 8 8 18 7 7.2 7. 7.7 8 8.2 8. ph 6 18 7 7.2 7. 7.7 8 8.2 8. ph 6 18 7 7.2 7. 7.7 8 8.2 8. ph Column:. cm I.D. x cm bed height (~1 ml). Sample: mg/ml BSA in equilibration buffer. Equilibration buffer: 2 mm Tris-HCl, ph 7. 8.. Conductivity 3 ms/cm. Residence time: 1 min (.2 1 ml/min). Numbers indicate binding capacity for BSA in mg/ml of sorbent. Data shown in Figure 3 confirms that DBC is less affected by conductivity in the 7 11 ms/cm range, compared to conventional sorbent. This allows direct load of undiluted plasma on HyperCel STAR AX sorbent. Combined with excellent flow characteristics at low backpressures (Figure 1), large volumes of feedstock can be processed directly and fast, increasing the overall process throughput, and limiting the risk of protein degradation. High binding capacity facilitates operation using columns of moderate volume and footprint, allowing further reduction in buffer-volume requirements, and leading to equipment savings and reduced investment costs for sorbents. Excellent Selectivity and Separation Efficiency over a Broad Range of Conductivities Figure Separation of a Protein Mix on HyperCel STAR AX Sorbent at ms/cm. A Design of Experiments study (DoE) was done to explore the influence of various phs (7. to 8.), conductivities (3 to ms/cm) and residence times (1 to minutes) on the dynamic binding capacity for bovine serum albumin (BSA) used as a model. mau 8 6 Cytochrome C Conductivity gradient Data shows the impact of ph and conductivity on DBC for BSA on HyperCel STAR AX sorbent. The contour plots in Figure 2 show that the sorbent achieves a high DBC (> mg/ml) over a wide range of phs and conductivities at short residence time, allowing optimal process flexibility and productivity. Figure 3 Dynamic Binding Capacity of HyperCel STAR AX Sorbent for Human Serum Albumin (HSA) from Undiluted and Diluted Plasma 3 7 ms/cm 11 ms/cm Transferrin Albumin 3 6 ml HyperCel STAR AX PRC prepacked column of 1 ml; µl mix (2 mg/ ml cytochrome C, mg/ml human transferrin, mg/ml bovine serum albumin [BSA]). Load: 2 mm Tris-HCl ph 8., ms/cm. Elute: gradient % 2 mm Tris-HCl, ph 8. + 1 M NaCl. Sorbent selectivity is a key parameter to discriminate between the target protein and contaminants in the feedstock. Screening of sorbent selectivity is critical and should be done at early stages of process development. HSA mg/ml 3 2 1 Rapid screening and condition optimization can be achieved using a Pall 1 ml PRC prepacked column. Once the appropriate chemistry is selected, the conditions of use can be optimized in a ml PRC column by doubling the height. Two ml columns can be connected in series to increase the column bed height to cm, and more closely model real conditions in pilot scale or for scale-down applications. Columns of 1 ml can also be connected in series. HyperCel STAR AX DEAE rigid agarose Figure 3 shows the DBC for HSA of HyperCel STAR AX sorbent compared to a conventional rigid agarose DEAE anion exchange sorbent at conductivities corresponding to undiluted (11 ms/cm) and diluted (7 ms/cm) plasma. Due to the difference in the bead structure, ligand chemistry and the specific ionic charge density, as shown in Figure, the selectivity and separation efficiency of HyperCel STAR AX sorbent is maintained in a broad range of conductivities. www.pall.com 3

. Applications and Examples Applications include direct capture of recombinant proteins, monoclonal and polyclonal antibodies, plasma derivatives or Optimal wash other biopharmaceuticals. condition Due to its ability to capture directly proteins from undiluted feedstreams, HyperCel STAR AX sorbent can also be used for early contaminant removal (i.e., CHO Host Cell Proteins), before target purification, i.e., before MAb capture by a Protein A affinity step. Application 1. Direct Capture of Albumin from Undiluted Plasma The objective is to evaluate HyperCel STAR AX sorbent as the first step in a two-step purification sequence to capture human serum albumin (HSA) from undiluted plasma (conductivity 11 ms/cm). HyperCel STAR AX sorbent was used as a first capture step, followed by an orthogonal cation exchange step performed on S HyperCel sorbent, without ph or conductivity adjustment of the plasma. Neat undiluted plasma (ph 7.6, 11mS/cm), was loaded with DBC of 3 mg/ ml (refer to Figure 3). Design of Experiments (DoE) in 96-well filter plates (AcroPrep Advance filter plates, Pall) was performed to determine optimal conditions to achieve the best yield/ purity ratio (one example of the optimization of wash/elution conditions is shown in Figure ). These conditions were then transferred to column chromatography on Pall PRC prepacked columns (Figure 6). Figure Impact of Washing (W) and Elution (E) Conditions on Purity of HSA and Elution Yield (in percentage) on HyperCel STAR AX Sorbent (Design of Experiments in 96-Well Filter Plates) Wash Conductivity (ms/cm) 1. Optimal wash condition 6. 6. Wash ph 7. 7. Purity (%) < 88 88 9 9 92 92 9 9 96 96 98 > 98 Hold values E ph 3. E cond. 2. Elution Conductivity (ms/cm) 3 3. Optimal elution condition... Elution ph. Yield (%) < 6 6 8 8 9 > 9 Hold values W ph 7. W cond. Figure shows that HSA yield is impacted mainly by elution conditions (optimal zone: ph 3..2 and conductivity 2 27 ms/cm) while purity is impacted mainly by wash conditions (high conductivity wash at >1 ms/cm improves purity). Figure 6 Transfer of Conditions Determined in 96-Well Plates to 1 ml HyperCel STAR AX PRC Prepacked Column. mau 2 1 Elution, ph., 2 ms/cm E FT from neat Wash 2, plasma load Wash 1 ph 7., ms/cm Albumin FT W1 W2 IgG Transferrin Albumin ml FT W1 W2 E P P = Plasma Conditions determined in 96-well plates were applied to chromatography of undiluted plasma on HyperCel STAR AX sorbent in a 1 ml PRC prepacked column. Chromatogram (Figure 6) and SDS-PAGE analysis of fractions confirmed that most contaminants were eliminated by high conductivity wash, leading to a 99% pure HSA fraction in a single step, with 9% yield. In addition, as shown before in Figure 3, HyperCel STAR AX sorbent used at capture step with undiluted plasma had a DBC >3 mg/ml, more than 2-fold higher than that of a conventional DEAE agarose sorbent tested in these conditions. HSA was eluted by a simple decrease of ph (.), without addition of salt, allowing a direct load on an orthogonal cation exchange column (S HyperCel sorbent). This last polishing step on S HyperCel sorbent led to a purified fraction of HSA eluted at ph 7. with purity >99%, and a capacity around 6 mg/ml (Table 2).

Table 2 Two-step Purification of Human Serum Albumin from Undiluted Plasma. Capture on HyperCel STAR AX sorbent Polishing on S HyperCel sorbent Load Undiluted plasma ph. eluate from HyperCel STAR AX sorbent Capacity Yield Purity (mg/ml) > 3 mg/ml 9% 99% 6 mg/ml 9% > 99% Application 2. Early Removal of CHOPs before Protein A Capture of a Monoclonal Antibody (MAb) The objective of this study was to evaluate the impact of a pre-purification step using HyperCel STAR AX sorbent before conventional Protein A sorbent capture of a monoclonal antibody (MAb) from mammalian cell culture feedstock (Figure 7). The content of contaminating CHOPs (Chinese Hamster Ovary Proteins) was compared using a commercial ELISA assay for the two purification schemes shown in Figure 7. Data shows that using HyperCel STAR AX sorbent prior to Protein A results in a better CHOP reduction (>8-fold). Due to this synergistic effect, starting from an initial Host Cell Protein (HCP) content of 13, ppm, the final CHOP level is reduced to ~ ppm (3-Log reduction), with a MAb recovery of 9%. A pre-purification step can impact positively process economics by extending the lifetime of an expensive Protein A column used as standard step for MAb capture. Ordering Information HyperCel STAR AX Sorbent Part Number ml 197-18 2 ml 197-26 ml 197-32 1 L 197-6 L 197-8 L 197-6 HyperCel STAR AX PRC Prepacked Columns Figure 7 Conventional and Alternative MAb Purification Scheme Including Pre-purification Step on HyperCel STAR AX Sorbent CCS CHOP: 13, ppm PRC Column x HyperCel STAR AX, 1 ml PRC Column 8x HyperCel STAR AX, ml Part Number PRCSTARAX1ML PRCSTARAXML HyperCel STAR AX FT mode CHOP: 362, ppm Protein A (bind/elute mode) Protein A (bind/elute mode) HyperCel STAR AX Sorbent Plates AcroPrep ScreenExpert Plates : HyperCel STAR AX Anion Exchange Sorbent Part Number 96WPSTARAX CHOP: ppm CHOP: 3,3 ppm. CHOP content x (ppm) 3. 3 2. 2 1. 1. 13 CCS 36 HyperCel STAR AX 33 Protein A HyperCel STAR AX + Protein A www.pall.com

Corporate Headquarters Port Washington, NY, USA +1.8.717.72 toll free (USA) +1.16.8. phone biopharm@pall.com e-mail European Headquarters Fribourg, Switzerland +1 ()26 3 3 phone LifeSciences.EU@pall.com e-mail Asia-Pacific Headquarters Singapore +6 6389 6 phone sgcustomerservice@pall.com e-mail Filtration. Separation. Solution.SM Visit us on the Web at www.pall.com/biopharm E-mail us at biopharm@pall.com International Offices Pall Corporation has offices and plants throughout the world in locations such as: Argentina, Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, India, Indonesia, Ireland, Italy, Japan, Korea, Malaysia, Mexico, the Netherlands, New Zealand, Norway, Poland, Puerto Rico, Russia, Singapore, South Africa, Spain, Sweden, Switzerland, Taiwan, Thailand, the United Kingdom, the United States, and Venezuela. Distributors in all major industrial areas of the world. To locate the Pall office or distributor nearest you, visit www.pall.com/contact. The information provided in this literature was reviewed for accuracy at the time of publication. Product data may be subject to change without notice. For current information consult your local Pall distributor or contact Pall directly. 13, Pall Corporation. Pall,, AcroPrep, and HyperCel are trademarks of Pall Corporation. indicates a trademark registered in the USA and TM indicates a common law trademark. Filtration.Separation.Solution. is a service mark of Pall Corporation. /13, PDF, GN13.8668 USD 2831 (2)