Product Bulletin.1:0 February 05 Type 0, 011, and Whisper Disk Because valves can be substantial noise contributors when controlling industrial processes, a complete line of Fisher diffusers is offered to provide optimum noise attenuation. A diffuser is a pressure-reducing device that is installed downstream from the control valve. The total pressure drop of the system is divided across the valve and a diffuser. This enables the valve to operate at a lower drop pressure ratio and greatly reduce the control valve noise level generated by steam, gas, or vapor flow. The Types 0, 011 and Whisper Disk (figure 1) inline diffusers are installed downstream of any control valve. Flexibility is key, whereas several installation methods are available, based on design of the diffusers. They are used in steam, gas, or vapor flow applications to achieve minimum noise generation. Note Neither Emerson, Emerson Process Management, nor Fisher assume responsibility for the selection, use, or maintenance of any product. Responsibility for proper selection, use, and maintenance of any Fisher product remains solely with the purchaser and end-user. W1 /IL W/IL W1155 /IL Figure 1. www.fisher.com www.cv000.com D019X0
Product Bulletin.1:0 February 05 Table 1. Construction Materials MATERIAL DIFFUSER FLANGE OR WHISPER DISK DIFFUSER TUBE DIFFUSER HEAD TEMPERATURE LIMITS CAP C F Steel (1) Steel (SA-5) Grade B (SA-) Grade WPB (SA-) 9 to 7 to 0 Alloy Steel () (1-1/ Cr-1/ MO) Grade F11 (SA-) Grade P11 (SA-5) Grade WP11 (SA-) -9 to 57 to 00 Alloy Steel () (-1/ Cr-1 MO) Grade F (SA-) Grade P (SA-5) Grade WP (SA-) 9 to 5 to 50 S0 (1 SST) Grade F1 (SA-) Grade TP1 (SA-) Grade WP1H (SA-0) 19 to 59 5 to 10 S000 (0 SST) Grade F0 (SA-) Grade TP0 (SA-) Grade WP0H (SA-0) 19 to 59 5 to 10 Nickel Alloy (Alloy 00) Grade 00 (B5) Grade 00 (B15) Grade WPNC (B) 19 to 7 5 to 0 1. Sour gas diffuser assembly can be heat treated to RHC (Rockwell C) maximum hardness as required by NACE MR0175.. Wrought equivalent to WC.. Wrought equivalent to WC9. Features Versatility The diffuser concept is used in several unique versions, providing optimum solutions for various applications. The diffuser need not be installed adjacent to the control valve. Noise Attenuation A properly selected diffuser-valve combination can result in up to 0 dba noise reduction. Total Control A diffuser-valve combination retains the pressure/flow control associated with a standard control valve. Just as important, it controls the generation of potentially damaging noise and vibration. Lower Life-Cycle Cost Two types of diffusers are available: the flat diffuser and the tube-and-shell diffuser for higher capacities. Both are ruggedly built static devices requiring no maintenance after installation. These features combine to offer increased noise control at a minimum investment. Ordering Information Contact your Fisher sales office to order diffusers. All Fisher diffusers are designed in Marshalltown Iowa, 5015, USA. The Diffuser Data Form, available on FishWEB, should be completed and sent to Marshalltown, along with the standard order entry. www.cv000.com
Product Bulletin.1:0 February 05 See figure and table. Type 0 Diffuser Table. Typical Type 0 Diffuser Dimensions (1) FLANGED BUTTWELD APPROXI- DIFFUSER () L D () L o MATE SIZE WEIGHT () mm Inch mm Inch mm Inch kg lb 0A D A17 1A/IL Figure. Type 0 Diffuser Dimensions (also see table ) 1 x 1.5 x x x.5 x x x x x x 1 x x 1 x x x 1 x 1 x x x 15 15 9 9 9 1 79 0 1 5 0 57 50 50 5.00.50.00 9.00 9.00 9.00 9.50 11.00 1.00 15.00.00 1.00 1.00 19.00 19.00 19.00.00.00 1.00 9 1 1 1 170 5 0 195 97 19 97 1.1.50.1 5.1 5.5 5. 5.9.9.0 9. 7.9 9.9 11.9.5.19 11.9..19.9 7 7 15 15 15 05 0 5 0 50 711 1 9 9 9 1 1 1. 1..5. 5. 7. 7 77 9 9 7 5 7.75.50 5.50 9.50 11.50 17 1 7 5 170 5 70 550 97 111 157 1. Dimensions may vary to meet specific sound attenuation or piping requirements.. Inlet x outlet nominal pipe sizes.. Dimensions are nominal pipe size.. Weights do not include optional flanges. Table. Minimum Outlet Head Size for Type 0 Diffusers (1) INLET TUBE NOMINAL PIPE SIZE, INCHES 1 1 1.5.5 1 1 MINIMUM OUTLET HEAD (NOMINAL PIPE SIZE), INCHES.5 5 1 0 MAXIMUM HEAD () SCHEDULE XXS XS STD only 0 0 MAXIMUM HEAD WALL THICKNESS mm 5.5 7.0 7. 17.1. 9.5.9...7.. 9.5 17.5.7 15.9 1. This chart may be used to determine physical size limitations. It is not intended to be used as a guide or substitute for outlet velocity calculations, or outlet sizing.. Larger head sizes are available on all inlet sizes. Inches 0.1 0.7 0.00 0.7 0.7 0.75 0. 1.5 1. 0.500 0.9 1.01 0.75 0. 0.500 0.5 www.cv000.com
Product Bulletin.1:0 February 05 See figure and tables and 5. Type 011 Diffuser 0A79 E A17 1B/IL Figure. Type 011 Diffuser Dimensions (also see table ) Table. Typical Type 011 Diffuser Dimensions (1) DIFFUSER MAXIMUM APPROXI- SIZE () MAXIMUM T TUBE SIZE MATE L D (,) (MATING T WEIGHT FLANGE) mm Inch mm Inch mm Inch kg lb 1 1 0 5 711 95 7 177 1 19 5 5 70 1 19 70 0. 0.75 0. 1. 1.5 1.50.00.00.00.00.75 7 7 15 5 5 5 5 0 50 1.5.50 5 1.7 9 1 11 159 11 0 97 5 5 0 150 50 50 00 5 750 75 00 1. Dimensions may vary to meet specific sound attenuation or piping requirements.. Specify mating flange size for diffuser size.. Heavy schedule mating flange may require smaller tube size.. Smaller tube sizes available for increased annular area. Table 5. Maximum Tube Size for Type 011 Diffusers (1) MATING LINE MAXIMUM TYPE 011 Maximum Allowable Mating Flange Line Size Maximum Schedule TUBE SIZE NPS Wall Thickness Inches Allowed (INCHES) mm Inches STD only XS STD only.9 5.5 5. 11.1 0.15 0.1 0.1 0. 1.5 1.5.5 1. 11.0 1. 1. 0.7 0. 0.719 0.719 5 0 0 1... 19.1 0.719 1. 0.5 0.750 1 1 0 0 XS XS 1....7.7 0. 0.9 0. 0.500 0.500 1 1. This chart may be used to determine physical size limitations. It is not intended to be used as a guide or substitute for outlet velocity calculations, or outlet sizing. www.cv000.com
Product Bulletin.1:0 February 05 Whisper Disk Diffuser See figure and tables, 7, and. Table. Available Size/Pressure Class for Whisper Disk Diffusers NOMINAL PIPE ANSI CLASS (1) SIZE, INCHES 150 00 00 00 0 1500 500 X X X X X X X.5 X X X X X X NA () X X X X X X NA X X X X X NA NA X X X X NA NA NA X X X NA NA NA NA X X NA NA NA NA NA X X NA NA NA NA NA - X NA NA NA NA NA NA 1. Ratings are for raised face flanges. Flange ratings higher than those listed may be available. Consult your Fisher sales office for higher flange ratings, other sizes, and RTJ (ring-type joint) facing.. Not Available Table 7. Whisper Disk Maximum Allowable C g (1) Per Disk Size and Pressure Drop Ratio (Pressure Drop Ratio of Disk, Not System) Size, Inches.5 1 1 P/P 1 (psia) Maximum of 0.0 0 50 500 00,000,0,0 5,000 5,000 5,000 5,000 P/P 1 (psia) Maximum of 0.75 95 95 0 5500 00 1,500,000 1,0,500 5,000 5,000 P/P 1 (psia) Maximum of 0.5 7 0 00 0 0 5 11,00,0 1,00 5,000 P/P 1 (psia) Maximum of 0.99 5 5 0 00 00 0 500 5500 550 0,0 1.000 1. Above C g values based on standard weight pipe upstream and downstream of disk diffuser. For heavier schedule or heavier flange maximum C g values, consult your Fisher sales office. www.cv000.com 5
Product Bulletin.1:0 February 05 Table. Thickness Dimension T for Whisper Disk Diffusers NOMINAL T, MILLIMETERS T, INCHES PIPE SIZE, ANSI Class ANSI Class INCHES (1) 150 00 00 00 0 1500 150 00 00 00 0 1500.5 1 1 19 5 0 5 7 0 5 7 1 5 1 5 1. For sizes and ratings not shown, contact your Fisher sales office. 5 5 5 5 0.75 0. 0.9 0.9 1.00 1. 1.19 1.5 1. 1. 1.5 1.9 1. 0. 1.00 1. 1.5 1. 1. 1..00 1.5 1. 1.50 1. 1.. 1.5 1. 1.50. 1..00 1... B07 A A0/IL Figure. Thickness Dimension T for Whisper Disk Diffusers (also see table ) www.cv000.com
Product Bulletin.1:0 February 05 Specifications Available Configurations Type 0: Inline diffuser (with integral outlet head) Type 011: Inline diffuser (insert type) Whisper Disk: Inline diffuser (flat plate) Sizes and End Connections Type 0: Both ends buttwelding end or both ends flanged; any combination is optional. Sizes and schedules are available to meet your application (see table ) Note Inline diffusers are not hydrostatically tested. Type 011: No bolted connections; designed to be retained between mating flanges. Sizes are available to meet your application (see table 5) Whisper Disk: See table for raised-face flanges; other sizes and connections are available. Consult your Fisher sales office Materials See table 1 Weights & Dimensions (1) Type 0: See figure and table. Type 011: See figure and table 5. Whisper Disk: See figure Sizing Types 0 and 011: See Fisher Catalog, Section Whisper Disk: See table 7 1. Your Fisher sales office can determine actual weights and lengths after the diffuser has been sized for pressure and noise conditions. Note Neither Emerson, Emerson Process Management, nor Fisher assume responsibility for the selection, use, or maintenance of any product. Responsibility for proper selection, use, and maintenance of any Fisher product remains solely with the purchaser and end-user. www.cv000.com 7
Product Bulletin.1:0 February 05 Whisper Disk and Fisher are marks owned by Fisher Controls International LLC, a member of the Emerson Process Management business division of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor Fisher assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Fisher product remains solely with the purchaser and end-user. Emerson Process Management Fisher Marshalltown, Iowa 5015 USA Cernay 700 France Sao Paulo 05 Brazil Singapore 1 www.fisher.com Fisher Controls International LLC 197, 05; All Rights Reserved www.cv000.com Printed in USA