SDS-CAD Specialized Design Systems Copyright 2002 Website: 26' x 38' Gambrel Barn

Similar documents
14' x 24' Garage Plan

E-Blueprints. Shed WorkShop Loft 20' x 20' 800 sq. feet Shed Roof 2 x Framed Walls 8' Doors 8' ceiling Height E-BLUEPRINTS C ABINS G ARAGES

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems

Custom 30 x 48-14' Tall Garage Plan #g226 By SDS-CAD Specialized Design Systems

E-Blueprints. 2 Car Garage 26' x 30' 780 sq. feet Trussed Roof 2 x 4 Framed Walls 7' Door 8' Ceiling Height E-BLUEPRINTS C ABINS G ARAGES

GARAGE MAIN FLOOR PLAN

Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN 1

GARAGE MAIN FLOOR PLAN 1

GARAGE MAIN FLOOR PLAN SDSCAD Specialized Design Systems

36 x 48 Barn. SDS-CAD Specialized Design Systems Copright Website 48'-0" 6'-0" 14'-9 13/16" 14'-9 13/16"

Sample Plan Not for Construction for pricing

2x4 Construction 10' Ceilings 36" Brick. 28' x 30' Garage Plan. 28' x 30' Garage

Gambrel Roof Garage 24' x 36' SDS-CAD Specialized Design Systems Copyright 2002

SDS-CAD Specialized Design Systems Copyright 2002 Website: 26' x 36' Garage With Loft

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN

#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems

BARN MAIN FLOOR PLAN. #G457a 12 x 20 x 8 Gentleman Bunkhouse Shed By SDS-CAD Specialized Design Systems 12'-0" 3'-0" 4'-0" 1'-6" 3'-0" 1'-6" 20'-0"

Cabin Plan 24' x 32' DECK. BEDROOM 9'-8" x 14'-0" LIVING 23'-0" x 16'-7" DECK. Main Floor Plan Scale 3/16"=1'

BWP BWP 8'-0" 5'-0" BWP 12'-0" 5'-0" 60'-0" GARAGE 19'-7" x 59'-0" GARAGE 14'-3" x 59'-0" BWP. 9' Ceiling Height 12'-0" 5'-0" BWP

Custom Home Design Plan #211 By SDS-CAD Specialized Design Systems

Custom Home Design Plan #204 Summit By SDS-CAD Specialized Design Systems

28' x 28' Cabin. Cabin Plan 28' x 28'

Custom Cabin Design Plan #221 24' x 32' Custom Cabin Chris Lavier By SDS-CAD Specialized Design Systems

Custom Home Design Plan #217 Cottage By SDS-CAD Specialized Design Systems

Custom Cabin Design Plan #178 By SDS-CAD Specialized Design Systems

Custom Home Design Plan #217 Cottage By SDS-CAD Specialized Design Systems

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

Left Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4" = 1'

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

GARAGE MAIN FLOOR PLAN

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED

APPLICATION FOR FINISHED BASEMENT PERMIT

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

Project Name: the candlelight. Project No. Scale: sewer line. water line 1 8"=1'-0"

2003 International Residential Building Code

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

front elevation right elevation

Table of Contents. Page Title

THE FLORIDA BUILDING CODE

CRM Homes BUILDER Mangan Drafting Jim Mangan

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Pulaski County, Virginia

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

Custom House Plans. Developed By SDS-CAD Specialized Design Systems Website:

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

Residential Building Inspections

Building Division Informational Handout

Typical Finished Basement Details

THE ASHTON PERSPECTIVE VIEW

STANDARD CONSTRUCTION PACKAGE Addendum A REV SITE & EXCAVATION Layout of the foundation and septic system as approved by local and state author

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

30 YR. ASPHALT ROOF SHINGLES HARDIE PLANK LAP SIDING SEE FIRST FLOOR PLAN FOR PORCH ROOF FRAMING DETAILS 3'-0" 2-2 X 8 HEADER COVERED PORCH 9'-4"

GARAGE MAIN FLOOR PLAN

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

One & Two Family Residential ADDITIONS

The better way to build TM. Installation Manual NAILBASE PANELS

Framing Methods Structural Components

RESIDENTIAL BUILDING PLAN REQUIREMENTS

Garage/Accessory Structures

* RESIDENTIAL PLAN REVIEW *

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

Applying for Permits to build a new house in Linn County

2'-0 1/2" 1'-8" 9'-7" TOILET BATHROOM 9 VINYL T.P. 3'-8" H.B. 48'-0" W.H. 6'-10" 13'-2" 12'-0" 6'-10" 7'-2" 6'-0" 12'-0" 6'-10" 25'-2"

BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS

Residential Building Plans

The Inspection Process. Waxhaw N.C.

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ S201 TW: 89'-0" TF: 86'-0" S201 TW: 87'-11 1/4" S201 TF: 86'-10 1/4" S201

One & Two Family Residential NEW CONSTRUCTION Plan Review Checklist

Administrative Changes

Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

Price, plans, and specifications are subject to change without notice. MAPLE 2,081 SQ.FT. 3 BEDROOMS 3.5 BATHROOMS 2 STORIES

COOPERSMITH COURT. For more information, contact: Maggie Houston

COOPERSMITH COURT. For more information, contact: Maggie Houston

One and Two Family Additions

ADDENDUM A CONSTRUCTION SPECIFICATIONS

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

TNH-SC-43-B DRAWING INDEX SYMBOLS AND ABBREVIATIONS AUG. 22, 2014 TNH-SC-43-B TRADITIONAL HOME SERIES C S 1.0 A 1.0 A 1.1 A 2.0 A 2.1 A 3.0 E 1.

Price, plans and specifications are subject to change without notice. Revised 01/2018

RESIDENTIAL DETACHED ACCESSORY STRUCTURES

Fairfax County, Virginia

EXW3 EXISTING DOWEL NEW FOOTING TO EXISTING WALL WITH 3-15M DOWELS, DOWEL THE NEW

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

HUMBOLDT COUNTY BUILDING & SAFETY DEPARTMENT CITY OF WINNEMUCCA BUILDING DEPARTMENT

Transcription:

26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

26'-0" 4' x 4' Slab 4' x 4' Slab 4" Concrete Slab w/ww mesh over 4" Gravel Fill 38'-0" 38'-0" 26'-0" 24'-0" 16' x 24' Concrete Slab Foundation Plan Scale 3/16"=1' 16'-0" 26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

26'-0" 19'-6" 6'-6" 10'-2 5/8" 9'-3 3/8" 3030 38'-0" 11'-10" 26'-2" 14'-0" 9'-8" 2'-6" 5'-10" 6'-0" 3046 3068 3046 WP 3 3 3 3 3068 Canning Kitchen 18'-10" x 11'-2" 2x12 joists 16" OC Micro Lam Beam 5 1/2" x 14" Min 3 3068 GFCI 3 Bath 5'-10" x 6'-8" UP 3 2868 3068 3 3068 3046 WP 3046 14'-0" 8'-10" 5'-7" 2'-3" 3'-6" 3'-10" 22'-10" 7'-10" 7'-4" 38'-0" 8070 WP 8070 7'-0" 12'-0" 7'-0" Main Floor Plan Scale3/16"=1' 26'-0" 26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

26'-0" 5'-0" 16'-0" 5'-0" 8'-0" 8'-0" 3046 CLOSET 4'-4" x 11'-2" 6068 BEDROOM 15'-7" x 11'-2" 11'-10" 6068 CLOSET 4'-4" x 11'-2" 2868 DN 38'-0" 38'-0" 25'-1" Proposed Loft Layout Scale 3/16"=1' 3046 9'-2" 9'-2" 3'-10" 18'-4" 3'-10" 26'-0" 26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

Ashphalt Shingles 6/12 Pitch 24/12 Pitch Red Wood Siding Front and Right Elevation Views Scale 1/8"=1' 26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

Rear and Left Elevation Views Scale 1/8"=1' 26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

UP 2 x 12 Floor Joists or TJI 16" o.c. Main Floor Framing Details Scale 1/8"=1' Typical Framing 16" o.c. 26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

5 1/2 x 14 Micro Lam or eq 2 x 12 Header Roof Framing Plan and Cross Sections Scale 1/8"=1' 26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

3030 W3030 WR2430 WR2430 W3030 W3030 Side-by-Side Elec (medium) BDR2436 BS3636 BD3636 Washer Dryer (gas) Canning Kitchen 18'-10" x 11'-2" G 3 3 3068 3068 Cabinets C1 1 BD3636 gar. base cab1 0 C2 1 34x6" utility cab. drawer 2 0 C3 1 16 15/16x21 RP-3-REC 1/2" door 4 (utility) 0 C4 1 countertop - 16 marble travertine 0 sqft C5 1 front cap (utility) 13 0 ft C6 1 backsplash (utility) 8 0 ft C7 1 BDR2436 gar. base cab1 0 C8 1 22x6" utility cab. drawer 1 0 C9 1 22x21 1/2" RP-3-REC door 1 (utility) 0 C10 1 W3030 gar. wall cab3 0 C11 1 13 15/16x28"RP-3-1CCATH 6 door (utility) 0 C12 1 BS3636 gar. base cab1 0 C13 1 WR2430 gar. wall cab2 0 C14 1 22x28" RP-3-1CCATH 2 door (utility) 0 Subtotal: Cabinet Details Scale 1/4"=1' 26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

Stair Cross Section Details Scale 1/4"=1' Length 145" Rise 7 1/4" Total Risers 15 Tread 10" Stair Width 36" Min Head Clearence 6'-8" Rail Height Min 32" Max 36" Angle 35 d 5' 5" Stringers 3-2 x 12 26' x 38' Gambrel Barn Website: www.sdscad.com Email: sdscad@pcu.net

Brick vaneer 1/2" gypsum wall board optional R-11 batt insulation optional base R-max insulating sheathing or 1/2" plywood 2" x 4" studs @ 16" oc simpson or equal m.a.b. anchor 3'6" oc & wind straps per code conc, slab 3000 psi, 4" min. 6-6#10 w.w. mesh finished floor level fin. grade slope to drain fill (2) #4 rebar contin. 6 mil poly compacted fill conc. footing (3000 psi) undisturbed soil footing 1'6 tall 1'4 wide MONOLITHIC SLAB with Brick Option 1x8 horizontal hardboard lap siding or stucco finish coat on stucco scratch coat on wire lath on # 15 felt on 1/2" cdx plywood 1/2" gypsum wall board R-11 batt insulation base R-max insulating sheathing or 1/2" plywood 2" x 4" studs @ 16" oc simpson or equal m.a.b. anchor 3'6" oc & wind straps per code stucco fin. grade slope to drain fill (2) #4 rebar contin. carpet conc, slab 3000 psi, 4" min. 6-6#10 w.w. mesh finished floor level 6 mil poly compacted fill conc. footing (3000 psi) undisturbed soil footing 1'6 tall 1'4 wide MONOLITHIC SLAB with SIDING or STUCCO Gambrel Roof Cabin 24' x 36' www.sdscad.net email sdscad@pcu.net

wood or hardboard siding or stucco finish coat on stucco scratch coat on wire lath on # 15 felt on 1/2" cdx plywood 1/2" gwb 7/16" osb board sheathing or 1/2" plywood r-11 batt insulation 2 x 4's 16" oc hurricane fasteners stud to sill plate every 3rd stud (or per local code) treated header block Simpson or eq. m.a.b. anchor, 3'-6" o.c. 2 4 base floor finish 4" conc. slab w/ 6x6 #10 mesh on 6 mil barrier NOTES: - footings shown are for standard soil bearing capacities - install perimeter slab #4 bar 8' oc 8" cmu fill solid w/ conc. # of blocks vary, depending on site conditions compacted fill with local codes stucco horizontal cmu wall ties 16" oc vert. where foundation wall is taller than 4 courses #3 bars. 4' oc #4 bars, continuous 8" 3000 psi conc. ftg. 1'4" RAISED SLAB with SIDING or STUCCO wood or hardboard siding or stucco finish coat on stucco scratch coat on wire lath on # 15 felt on 1/2" cdx plywood r-max sheathing or 1/2" plywood r-11 batt insulation 2 x 4's 16" oc hurricane fasteners stud to sill plate every 3rd stud 2 4 1/2" gwb base floor finish r-19 batt insulation 2 treated sill 8" cmu fill solid w/ conc. # of blocks vary, depending on site conditions stucco 10 2 8 provide sill plate anchor bolts, joist to footing straps & stud to 2x10 band wind ties per code horizontal cmu wall ties 16" oc vert. where foundation wall is taller than 4 courses varies #3 bars. 4' oc 2 # 4 bars, continuous 8" 3000 psi conc. ftg. 1'4" CRAWL SPACE FOUNDATION with SIDING or STUCCO Gambrel Roof Cabin 24' x 36' www.sdscad.net email sdscad@pcu.net

1/2" ANCHOR BOLTS 6' O.C. 4" CONCRETE FLOOR W/ WIRE MESH VAPOR BARRIER 4" GRAVEL BASE GRADE 6" 36" 8" POURED CONCRETE W/ VERTICAL REINF (IF REQUIRED) DAMP PROOFING (TO GRADE) 8" X 20" CONT. CONCRETE FOOTING RE-BAR (2) FOUNDATION - FROST (SLAB) - POURED CONC. BLK.8" X 34" 1/2" ANCHOR BOLT 6' O.C. 4" CONCRETE SLAB W/ WIRE MESH 6" MIN. GRADE 12" X 18" CONT. CONCRETE FOOTING REBAR (2) CONTINUOUS @ PERIMETER VAPOR BARRIER 4" GRAVEL BASE MONOLITHIC SLAB ON GRADE SINGLE POUR CORNER INSTALLATION ONE #4 REBAR IN SHEAR CONE 12" MINIMUM REBAR LENGTH Foundation details may vary depending on your local building conditions and codes. Consult a contractor or local building department to ensure proper techniques for your areas building codes. 2 x EMBEDMENT LENTH + 12" MINIMUN REBAR LENGTH 30" MINIMUM REBAR LENGTH Simpson Strong-Tie CORNER DISTANCE FROM EDGE OF STRAP TO CORNER HPAHD HPAHD_2.PL1 Simpson Strong-Tie HPAHD22 HPAHD_1.PL1 Foundation Details Details and Specifications Copyright 2001 SDSCAD E-Book Plans SDS - CAD Specialized Design Systems Web address www.sdscad.net Email: sdscad@pcu.net 1

ROOFING AND ROOF SHEATHING 12 4 ALTERNATIVE FRIEZE BLOCK W/SCREENED VENT LOCATION FRIEZE BLOCK W/SCREENED VENT TRIM CONTINUOUS FASCIA EXPOSED RAFTER TAIL STUD WALL WITH SHEATHING AND FINISH H10 H5 LTS12 SP2 SP4 H2.5 Eave and Truss Detail Details and Specifications Copyright 2001 SDSCAD E-Book Plans SDS - CAD Specialized Design Systems Web address www.sdscad.net Email: sdscad@pcu.net 2

Notes Western or Platform Framing Before any of the superstructure is erected, the first floor subflooring is put down making a platform on which the walls and partitions can be assembled and tilted into place. The process is repeated for each story of the building. This framing system is used frequently. Firestopping All concealed spaces in framing, with the exception of areas around flues and chimneys, are to be fitted with 2 in. blocking arranged to prevent drafts between spaces. Exterior Wall Framing One-story buildings: 2 x 4's 16 in. or 24 in. o.c.; 2 x 6's, 24 in. o.c. Two and three stories: 2 x 4's, 16 in o.c.; 2 x 6's, 24 in. o.c. Bracing Exterior Walls Because floor framing and wall frames do no interlock, adequate sheathing must act as bracing and provide the necessary lateral resistance. Where required for additional stiffness or bracing, 1 x 4's may be let into outer face of studs at 45 angle secured at top, bottom, and to studs. Bridging for Floor Joists May be omitted when flooring is nailed adequately to joist; however, where nominal depth-tothickness ratio of joists exceeds 6, bridging would be installed at 8 ft 0 in. intervals. Building codes may allow omission of bridging under certain conditions.

GENERAL NOTES: 2. VERIFY ALL DIMENSIONS PRIOR TO STARTING THE WORK. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. 3. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR MECHANICAL, ELECTRICAL AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS AND SUB-CONTRACTORS PRIOR TO CONSTRUCTION. 4. CONNECT WATER, GAS, ELECTRIC LINES TO EXISTING UTILITIES IN ACCORDANCE WITH LOCAL CITY BUILDING CODES. SOIL: 1. ALLOWABLE SOIL PRESSURE - 1500 P.S.F. MINIMUM MIN. FTG. DEPTH PER DETAILS. CONCRETE: 1. FOUNDATIONS - 3000 P.S.I. @ 28 DAYS. TYPE II CONC. 5 BAG. 3. PROVIDE CONSTRUCTION JOINTS @ 400 SQ. FT. MAXIMUM. 4. WALKS AND DRIVES - 3000 P.S.I. @ 28 DAYS, NO FLY ASH. STRUCTURAL STEEL: 2. BOLTS - ASTM A-307. LATEST AISC AND AWS CODES APPLY. ALL CONST. PER LATEST AISC HANDBOOK. MIN. EMBEDMENT OF ALL BOLTS IN MASONRY, GROUT OR CONC. TO BE 7". 3. ALL EXPANSION BOLTS TO BE "WEDGIT", RAM-SET, OR RED HEAD PHILLIPS (I.C.B.O. APPROVED) TYPE WITH A 360 EXPANSIVE WEDGING ACTION. 4. SEE DETAILS FOR SIZE. WELDING: STRUCTURAL 1. COMPLY WITH ALL APPLICABLE STATE, COUNTY AND LOCAL BUILDING CODES, ORDINANCES AND REGULATIONS PERTAINING TO THIS CONSTRUCTION. 2. PROVIDE TERMITE PROTECTION OVER A.B.C. PER GOVERNMENTAL REGULATIONS. 2. FLOOR SLABS - 3000 P.S.I. @ 28 DAYS. MAX. SLUMP = 3", NO FLY ASH 1. ASTM A-36, Fy = 36 KSI, STRUCTURAL TUBES SHAL BE ASTM A-500 (Fy-46KSI) 1. E70xx LOW HYDROGEN RODS LUMBER: 1. ALL SAWN LUMBER SHALL BEAR STAMP OF WWPA OR APPROVED TESTING AGENCY. 2. ROOF JOISTS, FLOOR JOISTS, BEAMS, LEDGERS AND PLATES TO BE DOUGLAS FIR #2 OR BETTER. 3. STUDS TO BE HEMLOCK FIR, STUD GRADE OR APPROVED EQUAL. TRUSSES: 1. TO BE MANUFACTURED BY CITY AND STATE APPROVED FABRICATOR. (AS REQ'D. BY GOVERNING MUNICIPALITY). Copyright 2001 SDSCAD E-Book Plans SDS - CAD Specialized Design Systems Web address www.sdscad.net Email: sdscad@pcu.net

NAILING SCHEDULE: 1. STUD TO SOLE PLATE END NAIL2-16d 2. DOUBLED STUDS FACE NAIL 16d @ 24" O.C. 3. DB. TOP PLATE FACE NAIL 16d @ 16" O.C. 4. TOP PLATE TO STUD END NAIL W/ 2-16d 5. HEADER TO STUD 3-16d 6. ALL OTHER NAILING SHALL BE PER U.B.C. TABLE 25-Q UNLESS OTHERWISE NOTED 7. EXTERIOR SIDING SHALL BE NAILED TO FRAMING WITH 6d NAILS @ 6" O.C. @ EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS. PLYWOOD: 1. ROOF PLYWD. SHALL BE 1/2" STD. GRADE SHEATHING (5-PLY) W/ EXTERIOR GLUE. SPAN INDEX RATIO 32/16 W/ STAMP OF APPROVED TESTING AGENCY OR ORIENTED STRAND BOARD NER-124. 2. ROOF PLYWOOD SHALL BE NAILED W/ 8d @ 16" O.C., EDGES, BEARING & BOUNDAR & 12" O.C. INTERMEDIATE. FRAMING: 1. JOIST HANGERS AND OTHER MISCELLANEOUS FRAMING ANCHORS SHALL BE AS MANUFACTURED BY SIMPSON COMPANY OR APPROVED EQUAL. 2. ALL BEARING STUD WALLS TO BE 2X's @ 16" O.C. INTERIOR AND EXTERIOR AS NOTED ON PLANS. 3. ALL BEARING PARTITIONS SHALL HAVE DOUBLE TOP PLATES. 4. ROOF AND FLOOR PLYWOOD SHEATHING PANEL EDGES SHALL BEAR ON FRAMING MEMBERS AND BUTT ALONG THEIR CENTER LINES WITH PANEL EDGES STAGGERE AND FACE GRAIN PERPENDICULAR TO SUPPORT. 5. FIRE STOPS SHALL BE PLACED IN ALL CONCEALED SPACES IN WALLS, AT FURRED SPACES & AT FLOOR/CEILING LEVELS SO THAT NO CONCEALED SPACE EXCEEDS TEN FEET. REINFORCING STEEL: 1. ASTM A615-60. FY = 60 KSI. 2. STEEL REINFORCING BARS SHALL BE DEFORMED GRADE 60. LAP VERTICAL BARS A MIN. OF 36 BAR DIAMETERS. TIE W/ APPROVED WIRE TIES. Copyright 2001 SDSCAD E-Book Plans SDS - CAD Specialized Design Systems Web address www.sdscad.net Email: sdscad@pcu.net

SITE WORK: 1. MAKE SURE SETBACKS ARE IN COMPLIANCE WITH THOSE SHOWN ON PLANS. 2. SEISMIC ZONE, NO. 3. 3. ALL STUMPS ROOTS AND ORGANIC MATTER SHALL BE REMOVED FROM THE SOIL IN THE AREA OF THE BUILDING. 4. LOT MUST BE GRADED TO INSURE PROPER DRAINAGE. THIS MUST BE COMPLETED PRIOR TO FINAL INSPECTION. 5. SOIL SHOULD NOT BE A HIGHLY EXPANSIVE SOIL TYPE WITH OUT HAVING A SOIL REPORT PREFORMED BY A SOILS ENGINEER AND RECEIVING APPROVAL FROM LOCAL BUILDING DEPARTMENT TO CONSTRUCT BUILDING ON SAID TYPE SOIL. 6. SOIL BEARING CAPACITY ASSUMED TO BE 1500 PSI AT 2' BELOW ADJACENT FINISHED GRADE FOR DESIGN. 7. FINISHED FLOOR TO BE 16" MIN. ABOVE LOT'S OUTFALL. 8. THAT PORTION OF THE FOUNDATION WHICH SUPPORTS TWO STORIES SHALL HAVE AN 8" MIN. STEMWALL. 9. BOTTOM OF FOOTINGS SHALL BE PLACED 30" MIN. BELOW EXISTING GRADE AND TOPS OF STEMS SHALL BE 10" MIN. ABOVE FINISHED GRADE. CONCRETE: 1. ALL SLABS ARE TO BE 4" CONC. OVER 4" GRAVEL UNLESS OTHERWISE NOTED ON THE PLANS. 2. CONCRETE TO BE ACI 301-66, TYPE II CEMENT, 2500 P.S.I. AT 28 DAYS, 5" MAX. SLUMP. 3. REINFORCING TO BE ASTM A615-BARS WITH Fy=60 K.S.I. LAP 30 DIA. MIN. AT SPLICES OR WELD PER ACI STD. 4. CONCRETE DESIGN BASED ON Fc 2000 P.S.F., Fc 2500 P.S.I. FOR QUALITY ONLY. 5. ANCHOR BOLTS SHALL BE A-307 EMBEDDED 7" MIN. INTO CONCRETE OR MASONRY GROUT. ROOF FRAMING: 1. FASCIA TO BE 2"x 4" DOUGLAS FIR PER DETAIL SHEET. 2. FOR SOFFIT SIZE SEE DETAIL SHEET. 3. FOR SPANS AND DIMENSIONS REFER TO FLOOR PLANS. 4. TRUSSES ARE TO BE AN APPROVED TRUSS DESIGN FROM THE TRUSS MANUFACTURE'S ENGINEER. 5. USE SIMPSON H-1 HURRICANE ANCHORS AT EACH TRUSS OR RAFTER TO WALL CONNECTION. 6. SOLID BLOCKING REQUIRED BETWEEN JOISTS, RAFTERS, AND TRUSSES OVER ALL BEARING WALLS. SUCH BLOCKING SHALL BE 1 1/2" MIN. THICKNESS AND FULL DEPTH OF JOISTS, RAFTERS, OR TRUSSES. 7. MINIMUM HEADER SIZES SHALL BE ACCORDING TO THE HEADER SIZE TABLE UNLESS OTHERWISE NOTED. 8. BASIS OF DESIGN ROOF LIVE/SNOW LOAD OF 37 P.S.F., AND ROOF DEAD LOAD OF 15 P.S.F. 9. PLYWOOD ROOF DECKING TO BE 1/2" THICK, 24/0, CDX OF 7/16 WAFFER. WOODS AND PLASTICS: GENERAL FRAMING: (DOUGLAS FIR) 1. MINIMUM HEADER SIZES SHALL BE ACCORDING TO THE FOLLOWING TABLE UNLESS OTHERWISE NOTED. HEADER SIZES (SINGLE STORY CONSTRUCTION) 2'-0" TO 4'-0" SPAN 2-2x4's 4' + TO 6'-0" SPAN 2-2x6's 6' + TO 8'-0" SPAN 2-2x8's 8' + TO 10'-0" SPAN 2-2x10's 10' + TO 12'-0" SPAN 2-2x12's HEADER SIZES (TWO STORY CONSTRUCTION) 2'-0" TO 3'-0" SPAN 2-2x4's 3' + TO 5'-0" SPAN 2-2x6's 5' + TO 7'-0" SPAN 2-2x8's 7' + TO 8'-0" SPAN 2-2x10's 2. BRACE ALL EXTERIOR WALLS AND CROSS-STUD PARTITIONS AT EACH END OF BUILDING AND AT LEAST EVERY 25' OF LENGTH BUY ONE OF THE FOLLOWING: A. SIMPSON WB 126 WALL BRACING WITH 3-16d NAILS AT EACH END AND 1-8d NAILS AT EACH STUD. B. PLYWOOD SHEATHING OF A MINIMUM THICKNESS OF 3/8 INCH. 3. FIRE STOPPING: A. FIREBLOCK STUD SPACES OVER 10' IN HEIGHT, FURRED SPACES, SOFFITS, DROP CEILINGS, COVE CEILINGS, STAIR STRINGERS AT TOP AND BOTTOM OF RUN, BEARING WALLS AND CEILING JOIST LINES, ETC. FIRESTOPPING SHALL CONSIST OF 2" NOMINAL LUMBER B. FIRESTOP OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, AND FIREPLACES AT CEILING AND FLOOR LEVELS WITH APPROVED NONCOMBUSTIBLE MATERIALS. 4. CDX PLYWOOD IS NOT APPROVED WHERE EXPOSED TO WEATHER, I.E. ROOF OVERHANGS. 5. EXTERIOR WALL FRAMING TO BE 2"x 6" STUDS AT 16" O.C.. INTERIOR WALL FRAMING AT NON-BEARING WALLS TO BE 2"X 4" STUDS AT 24" O.C. AND AT BEARING WALLS 2"x 4" STUDS AT 16" O.C. WITH DOUBLE TOP PLATE. 6. SHEAR WALL TO BE 3/8" CDX PLYWOOD APPLIED HORIZONTALLY. 7. ALL STRESS GRADE LUMBER SHALL COMPLY WITH WCLA SPECS. AND BEAR APPROVAL STAMP ON ALL PIECES IN PLACE. 8. FRAMING LUMBER SHALL BE DOUGLAS FIR CONSTRUCTION GRADE Fb 1450 OR BETTER UNLESS OTHERWISE NOTED. 9. NAILING TO BE PER CURRENT U.B.C. UNLESS OTHERWISE NOTED. 10. ALL BEARING PARTITIONS SHALL HAVE DOUBLE TOP PLATES. 11. STRUCTURAL GLUED LAMINATED TIMBERS TO BE STAMPED BY AN APPROVED AGENCY. 12. USE REDWOOD OR PRESSURE TREATED SOLE PLATES AT ALL EXTERIOR WALLS. FLOOR FRAMING: 1. ALL FLOOR JOIST TO BE DOUGLAS FIR #2 OR T.J.I. @ 16" O.C. UNLESS OTHERWISE NOTED. 2. FOR SPANS AND DIMENSIONS REFER TO FLOOR PLANS. 3. USE SIMPSON H 2.5 HURRICANE ANCHORS AT EACH FLOOR JOIST TO BEARING WALL CONNECTION. 4. SOLID BLOCKING BETWEEN JOISTS OVER ALL BEARING WALLS, AND MIDSPANS SUCH BLOCKING SHALL BE 2" MIN. THICKNESS AND FULL DEPTH OF JOISTS. 5. MINIMUM HEADER SIZES SHALL BE ACCORDING TO THE HEADER SIZE TABLE UNLESS OTHERWISE NOTED. 6. BASIS OF DESIGN: FLOOR LIVE LOAD OF 40 P.S.F., AND FLOOR DEAD LOAD OF 15 P.S.F. 7. FLOOR DECKING TO BE 3/4" THICK T & G WAFER BOARD. 8. JOIST HANGERS TO BE SIMPSON U210 OR EQUAL UNLESS OTHERWISE NOTED. 9. DOUBLE JOISTS AND OR DOUBLE BLOCKING AT ALL INTERIOR WALLS. STAIRS: 1. STAIRS TO BE CONSTRUCTED WITH THE FOLLOWING MATERIALS: 2x6 KICK PLATE ANCHOR TO CONCRETE WITH EXPANSION TYPE ANCHOR BOLTS, 2x12 TREADS NOSING 1 1/8" MIN., 3-2x12 STRINGERS REQUIRED, 2x12 BLOCKING, 3/4" WAFER BOARD RISERS AND 2x6 LEDGER. 2. HANDRAIL/GUARDRAILS FINAL STYLE, MATERIAL AND COLOR TO BE OWNER'S CHOICE. DESIGN TO BE PER U.B.C. 1994. 3. GUARDRAILS TO BE 42" HIGH MIN. FROM FLOOR. 4. HANDRAILS TO BE 34"-38" ABOVE TREAD NOSING. 5. OPEN RAILING TO HAVE INTERMEDIATE RAILS OR ORNA- MENTAL PATTERN SUCH THAT A SPHERE 4" ROUND CANNOT PASS THOROUGH. 6. MINIMUM STAIR REQUIREMENTS: MAX. 8" RISE, MIN. 9" RUN, MINIMUM HEAD CLEARANCE 6'-8". 7. PREFERRED STAIR REQUIREMENTS: RISE 7" TO 7 1/2", RUN 11" TO 12", MINIMUM HEAD CLEARANCE 7'-0". THERMAL AND MOISTURE PROTECTION: 1. ASPHALT SHINGLES OVER TYPE 30 FELT OVER 7/16" MIN. WAFFER BOARD WITH FOUR NAILS EACH. 2. R-38 INSULATION IN CEILING AND R-19 INSULATION IN EXTERIOR WALLS. 3. INSTALL CAULKING COMPOUND AT ALL PENETRATIONS IN BUILDING ENVELOPE, I.E., HOLES DRILLED IN TOP PLATES AROUND WINDOWS, DOORS, SERVICE ENTRANCE PANEL. 4. ENCLOSED ATTICS AND SPACES BETWEEN RAFTERS SHALL HAVE CLEAR CROSS-VENTILATION AREAS TO THE OUTSIDE. VENTS SHALL PROVIDE AIR INTAKE TO MEET SEC. 3205 (C) CURRENT U.B.C.. ATTICS SHALL BE PROVIDED WITH AN ACCESS OPENING 22"x30" WITH MIN. HEAD ROOM ABOVE ACCESS OPENING OF 30". 5. POLYSTRENE INSUL. BD. SHALL NOT BE EXPOSED TO ATTIC. REPLACE POLYSTRENE INSUL. BD. AT ATTIC WITH APPROVED BLACK INSUL. BD. OR SEPARATE POLYSTRENE INSUL. BD. FROM ATTIC WITH 1 LAYER OF 1/2" SHEETROCK (SEC. 1712(B)3, CURRENT U.B.C.). DOORS, WINDOWS, AND GLASS: 1. ALL BEDROOM WINDOWS TO BE 44" MAX. OFF OF FINISHED FLOOR. SUCH WINDOWS SHALL HAVE A CLEAR OPENING OF 5.7 SQ. FT. MIN., CLEARANCE HEIGHT OF 24" MIN., CLEARANCE WIDTH 20" MIN. PER SEC.1204 CURRENT U.B.C.. 2. ALL INTERIOR DOORS TO HAVE BASE BOARD TYPE DOOR STOPS (HINGE TYPE OPTIONAL). 3. ALL EXTERIOR DOORS TO BE SOLID CORE. 4. DOOR OPENING INTO THE GARAGE FROM THE LIVING QUARTERS TO BE SOLID CORE AND EQUIPPED WITH A SELF CLOSING DEVICE. 5. FRAMELESS GLASS DOORS, GLASS IN DOORS, FIXED GLASS PANELS AND ALL GLASS WITHIN 18" OF FLOOR OR 12" OF ANY DOOR AND SIMILAR GLAZED OPENINGS SUBJECT TO HUMAN IMPACT SHALL BE TEMPERED GLASS AND COMPLY WITH SEC. 5406 CURRENT U.B.C.. FINISHES: 1. FINISHED CEILINGS TO HAVE 1/2" DRYWALL W/ SKIP TOWEL FINISH OR AS DIRECTED BY OWNER / BUILDER. 2. INTERIOR WALL TO HAVE 1/2" DRYWALL TEXTURED AS DIRECTED BY OWNER / BUILDER. 3. 5/8" DRYWALL IS REQUIRED AT STAIRWAYS WALLS, CEILING AND UNDER STAIRS. 4. 5/8" DRYWALL ON CEILING (TYPE "X") OF GARAGE AND WALLS OF GARAGE ADJACENT TO LIVING AREA. 5. USE 5/8" SHEET ROCK ON CEILING WHERE SUPPORTED AT 24" ON CENTER. 6. DRYWALL SHALL BE NAILED 4" O.C. AT EDGES & 6" O.C. IN THE FIELD OF EACH SHEET. 7. USE TYPE "WR" SHEETROCK AS BACKING AT ALL SHOWER LOCATIONS ALONG WITH CERAMIC TILE OR APPROVED EQUAL TO A HEIGHT OF 70" ABOVE FLOOR DRAIN. (SEC.5406 CURRENT U.B.C.) MASONRY: 1. PROVIDE HORIZONTAL JOINT REINFORCING AT 16" O.C. FOR ALL MASONRY WORK. 2. BRICK VENEER SHALL BE FASTENED TO WALL PER SEC. 3006.1, CURRENT U.B.C. 3. ALL MASONRY MATERIALS USED MUST COMPLY WITH SECTION 2403 CURRENT U.B.C. PLUMBING: 1. INSPECTION IS REQUIRED PRIOR TO BACKFILL OF WATER, GAS AND SEWER LINES. 2. INSTALL APPROVED AIR-GAP FITTINGS ON DISCHARGE SIDE OF DISHWASHER. 3. ALL EQUIPMENT TO BE NEW AND OF EQUAL QUALITY AS SPECIFIED. 4. AFTER THE PLUMBING SYSTEM INSTALLATION IS COMPLETED THE CONTRACTOR SHALL CONDUCT AN OPERATION TEST FOR APPROVAL. 5. PLUMBING SHALL BE DESIGNED FOR WATER SOFTENING EQUIPMENT EXCEPT THAT RAW WATER LINES SHALL BE PROVIDED TO OUTSIDE HOSE BIBS. 7. ALL SHOWER HEADS ARE TO BE INSTALLED AT 6'-6" ABOVE FINISHED FLOOR OF SHOWER OR TUB. 8. USE ABS FOR WASTE AND VENT PIPING AND COPPER FOR WATER PIPING. 9. PROVIDE HOT WATER RELIEF VALVE FOR WATER HEATER AND DRAIN. 10. MAIN PLUMBING STACKS SHALL RUN UNDIMINISHED IN SIZE (3" MIN.) AND DIRECT AS POSSIBLE FROM THE MAIN DRAIN TO THE OPEN AIR ABOVE THE ROOF. 11. TOILETS TO BE SET WITH A MIN. OF 15" FROM ITS CENTER TO A VERTICAL SURFACE (SEC. 907(C) U.P.C. & SEC. 511(A) CURRENT U.B.C.) CLIMATE CONTROL: 1. FOR A/C UNITS INSTALLED EITHER IN ATTIC OR ON SECOND FLOOR AN EXTRA CORROSIVE RESISTANT WATER TIGHT PAN IS REQUIRED PER U.M.C. SEC. 1202. 2. PROVIDE EXHAUST FAN AT BATHROOM AND AT THE KITCHEN WHERE SHOWN ON THE PLANS. 3. DUCTWORK SHALL COMPLY WITH CH. 10 OF CURRENT U.B.C. 4. FURNACE SYSTEM AND INSTALLATION OF FURNACE TO COMPY WITH CHAPTER 7 OF CURRENT U.B.C. 5. ALL DUCT REGISTERS TO BE OPERABLE AND ABLE TO BE SMOOTHLY CLOSED AND OPENED BY THE HOME OWNER. ELECTRICAL SYSTEMS: 1. INSPECTION IS REQUIRED PRIOR TO BACKFILL OF LINES. 2. PROVIDE 20 FT. OF NO. 4 COPPER WIRE AS GROUND ELECTRODE INFOUNDATION FOOTING. 3. BOND INTERIOR PIPING SYSTEM WITH #8 BARE COPPER. 4. PROVIDE MAIN JUMPING BOND WITH #4 BARE COPPER. 5. ELECTRICAL SERVICE IS TO BE 100 AMP SERVICE, 120/240 VOLT, 1 PHASE RAINTIGHT, UNDERGROUND. 6. PROVIDE SEPARATE 20 AMP CIRCUITS TO WASHER. 7. PROVIDE 20 AMP CIRCUITS TO FAMILY AND DINING ROOM, AND A MINIMUM OF TWO 20 AMP CIRCUITS TO KITCHEN. 8. PREWIRE FOR T.V., TELEPHONE IN KITCHEN, FAMILY ROOM, LIVING ROOM, AND IN EVERY BEDROOM. 9. INSTALL GROUND FAULT CURRENT INTERRUPTER ON EX- TERIOR, GARAGE, KITCHEN AND BATHROOM OUTLETS. 10. BOTTOM HALF OF OUTLET CONTROLLED BY SWITCH WHEN SHOWN. 11. ALL OUTLETS IN KITCHEN ARE TO BE AT +44" EXCLUDING THOSE FOR THE REF'G., RANGE, DISP., DISHWASHER. 12. MAXIMUM SPACING OF OUTLETS SHALL NOT EXCEED 12 FT. ALONG WALL LINE AND AT ANY WALL OVER 24" WIDE IN ALL ROOMS EXCEPT KITCHEN, BATH, UTILITY, GARAGE. 13. INSTALL LIGHT IN WALK-IN CLOSET 18" MIN. HORIZ. FROM ANY SHELF. 14. PROVIDE A VENTILATION FAN CAPABLE OF PRODUCING A CHANGE OF AIR EVERY 12 MINUTES FOR BATH OR UTILITY ROOMS WITHOUT THE REQUIRED WINDOW VENTILATION. 15. PROVIDE SMOKE DETECTOR ALARM CONFORMING TO SEC. 1210(A) U.B.C. AND LOCAL BUILDING CODES IN EVERY BEDROOM AND ON EACH FLOOR.

ID Su Flr Size Item Count Un 1 General 2 GN1 0 24 1/4 high walfoundation 8" Concrete Stem 126 ft 3 GN2 1 97 1/8 high walsiding-8 127 ft 4 GN3 1 97 1/8 high walinterior-4 55 ft 5 GN4 2 5 1/16 high walsiding-8 76 ft 6 GN5 2 97 1/8 high walsiding-8 52 ft 7 GN6 2 80 9/16 high wainterior-4 26 ft 8 GN7 2 97 1/8 high walinterior-4 38 ft 9 GN8 2 109 1/8 high wainterior-4 18 ft 10 GN9 2 41 11/16 high winterior-4 4 ft 11 GN10 2 46 9/16 high wainterior-4 4 ft 12 GN11 2 heated ceiling area 988 sqft 13 GN12 2 heated wall area 351 sqft 14 GN13 2 heated glass area 27 sqft 15 GN14 3 53 3/8 high walsiding-8 36 ft 16 Subtotal: 17 Foundation 18 FO1 0 8" thick Concrete Concrete 6.24 cuyd 19 FO2 0 2x6" treated mud sill 126 ft 20 FO3 0 1/2x6" foam sill seal 126 ft 21 FO4 0 foundation bolts 24 22 FO5 0 16x8"h concrete footing 4.12 cuyd 23 FO6 0 no. 4 rebar (footing) 267 ft 24 FO7 0 no. 4 horiz. rebar (wall) 800 ft 25 FO8 0 no. 4 vert. rebar (wall) 259 ft 26 FO9 1 988 sq ft concrete slab 12.19 cuyd 27 FO10 1 988 sq ft steel mesh for slab 988 sqft 28 Subtotal: 29 Subfloor 30 SF1 2 4x8'x3/4" sheetfloor sheathing 30 31 SF2 2 2x12"-16'+ rim joists - lumber 128 ft 32 SF3 2 2x12"-26' floor joists - lumber 30 33 SF4 2 2x12"-16'+ floor joists - lumber 20 ft 34 SF5 2 2x12"-10' floor joists - lumber 2 35 SF6 2 2x6"-18' ceiling joists - lumber 28 36 Subtotal: 37 Framing 38 F1 1 2x6-16ft+ fir plate 393 ft 39 F2 1 2x6"-92 5/8" fir stud 97 40 F3 1 2x6-16ft+ fir stud stock 112 ft 41 F4 1 2x4"-92 5/8" fir stud 55 42 F5 1 2x7-16ft+ header - lumber 67 ft 43 F6 1 2x6"-9 7/8" fir stud 4 44 F7 1 2x6"-1 5/8" fir stud 12 45 F8 1 2x12-16ft+ header - lumber 34 ft 46 F9 1 2x4-16ft+ fir plate 164 ft 47 F10 1 2x4"-5 7/8" fir stud 9 48 F11 1 2x4-16ft+ fir stud stock 47 ft 49 F12 1 2x4"-7 5/8" fir stud 2 50 F13 1 2x6-16ft+ header - lumber 6 ft 51 F14 2 2x6-16ft+ fir plate 417 ft 52 F15 2 2x6-16ft+ fir stud stock 119 ft 53 F16 2 2x6"-92 5/8" fir stud 30 54 F17 2 2x7-16ft+ header - lumber 14 ft 55 F18 2 2x4"-92 5/8" fir stud 31 56 F19 2 2x4-16ft+ fir plate 282 ft 57 F20 2 2x4"-77 1/8" fir stud 23

ID Su Flr Size Item Count Un 58 F21 2 2x4-92 5/8" Fir Stud 16" OC 25 59 F22 2 2x4-16ft+ fir stud stock 61 ft 60 F23 2 2x4"-7 5/8" fir stud 2 61 F24 2 2x6-16ft+ header - lumber 6 ft 62 F25 2 2x4"-1 7/8" fir stud 5 63 F26 2 2x11-16ft+ header - lumber 13 ft 64 F27 3 2x6-16ft+ fir plate 78 ft 65 F28 3 2x6-16ft+ fir stud stock 61 ft 66 Subtotal: 67 Siding 68 S1 1 11 1/2" wide Siding Wood Pine 970 ft 69 S2 1 4x8x1/2 Sheet Sheetrock 15 70 S3 1 house wrap 1063 sqft 71 S4 2 11 1/2" wide Siding Wood Pine 449 ft 72 S5 2 4x8x1/2 Sheet Sheetrock 22 73 S6 2 house wrap 420 sqft 74 S7 3 11 1/2" wide Siding Wood Pine 91 ft 75 Subtotal: 76 Ext Trim 77 EX1 1 1x4-16ft+ exterior sill - color 9, white 18 ft 78 EX2 1 1x4-16ft+ ext. window casing - color 9, w 63 ft 79 EX3 1 1x7-36" 2 80 EX4 1 1x4-16ft+ ext. door casing - color 9, whit 18 ft 81 EX5 1 7 in ext. door jamb - color 9, white 18 ft 82 EX6 1 1x4-16ft+ garage door casing - color 9, w 47 ft 83 EX7 1 7 in garage door jamb - color 9, wh 47 ft 84 EX8 1 1x4-16ft+ ext. door casing 53 ft 85 EX9 1 7 in ext. door jamb 18 ft 86 EX10 1 1x5-36" 2 87 EX11 1 5 in ext. door jamb 35 ft 88 EX12 1 48" wide Fir Stock Std. + Btr. 21 ft 89 EX13 2 1x4-16ft+ exterior sill - color 9, white 8 ft 90 EX14 2 1x4-16ft+ ext. window casing - color 9, w 27 ft 91 Subtotal: 92 Roofing 93 R1 1 ridge cap 123 ft 94 R2 1 Roofing Dimensional Comp. 1748 sqft 95 R3 1 4x8' sheets roof sheathing 55 96 R4 1 2x6" 16" OC rafters - fir 1479 ft 97 R5 1 2x8" gable fascia 86 ft 98 R6 1 2x8" eave fascia 82 ft 99 R7 1 metal drip edge 168 ft 100 R8 1 gutter 82 ft 101 R9 1 downspout 2 102 R10 2 2x8"-16'+ ridge board - lumber 123 ft 103 R11 2 2x6"-12' rafters - lumber 40 104 R12 2 2x8"-41' rafters - lumber 2 105 R13 2 2x8"-13' rafters - lumber 4 106 R14 2 4x2"-16'+ rafters - lumber 80 ft 107 R15 2 2x6"-10' rafters - lumber 4 108 R16 2 2x6"-11' rafters - lumber 36 109 R17 2 2x8"-11' rafters - lumber 4 110 Subtotal: 111 Insulation 112 IN1 2 12x16x48" battsceiling insulation 185 113 IN2 2 6x16x93" batts wall insulation 32 114 Subtotal:

ID Su Flr Size Item Count Un 115 Flooring 116 FL1 2 Carpet b4 852 sqft 117 FL2 2 4x8' sheets underlayment 28 118 Subtotal: 119 Wall Brd 120 WB1 0 4x8'-1/2" ceiling wall board 29 121 WB2 1 4x8x1/2 Sheet Sheetrock 46 122 WB3 1 4x8'-1/2" ceiling wall board 30 123 WB4 1 4x8x1/2 (wp) - sheet sheetrock 2 124 WB5 2 4x8x1/2 Sheet Sheetrock 34 125 WB6 2 4x8'-1/2" ceiling wall board 31 126 WB7 3 4x8x1/2 Sheet Sheetrock 3 127 Subtotal: 128 Windows 129 W1 1 36x36 double hung - color 9, white 1 130 W2 1 36x54 double hung - color 9, white 4 131 W3 2 36x54 double hung - color 9, white 2 132 Subtotal: 133 Doors 134 D1 1 36x80x1 3/4R ext. - color 9, white 1 135 D2 1 96x84 garage - color 9, white 2 136 D3 1 36x80x1 3/4L ext. 2 137 D4 1 36x80x1 3/4R ext. 1 138 D5 1 32x80x1 3/8R 1 139 D6 2 32x80x1 3/8L 1 140 D7 2 36x80 bifold 1 141 Subtotal: 142 Cabinets 143 C1 1 BD3636 gar. base cab 1 144 C2 1 34x6" utility cab. drawer 2 145 C3 1 16 15/16x21 1/2RP-3-REC door (utility) 4 146 C4 1 countertop - marble travertine 16 sqft 147 C5 1 front cap (utility) 13 ft 148 C6 1 backsplash (utility) 8 ft 149 C7 1 BDR2436 gar. base cab 1 150 C8 1 22x6" utility cab. drawer 1 151 C9 1 22x21 1/2" RP-3-REC door (utility) 1 152 C10 1 W3030 gar. wall cab 3 153 C11 1 13 15/16x28" RP-3-1CCATH door (utility) 6 154 C12 1 BS3636 gar. base cab 1 155 C13 1 WR2430 gar. wall cab 2 156 C14 1 22x28" RP-3-1CCATH door (utility) 2 157 Subtotal: 158 Int Trim 159 T1 1 1x2-16ft+ window apron - color 9, white 17 ft 160 T2 1 1x2-16ft+ sill - color 9, white 17 ft 161 T3 1 1x2-16ft+ interior casing - color 9, white 78 ft 162 T4 1 1x2-16ft+ interior casing 85 ft 163 T5 1 5 in interior jamb 17 ft 164 T6 1 36x11 3/8-1" stair tread 14 165 T7 1 36x7 1/4" riser 14 166 T8 1 14 treads stair stringer 2 167 T9 2 1x2-16ft+ window apron - color 9, white 7 ft 168 T10 2 1x2-16ft+ sill - color 9, white 7 ft 169 T11 2 1x2-16ft+ interior casing - color 9, white 26 ft 170 T12 2 3 1/2" wide int. railing 158 in 171 T13 2 3 1/2" wide middle rail 158 in

ID Su Flr Size Item Count Un 172 T14 2 1 3/4" diam. baluster 29 173 T15 2 3 1/2" square newel post 4 174 T16 2 3 1/2" square half newel post 1 175 T17 2 1x2-16ft+ interior casing 74 ft 176 T18 2 5 in interior jamb 37 ft 177 T19 2 1x6-16ft+ base molding 281 ft 178 Subtotal: 179 Fixtures 180 FX1 1 36W36D Corner (right) - color 10, shiny 1 181 FX2 1 30W19D Free Standing (rect) - color 10 1 182 FX3 1 31W34D Standard - color 10, shiny whit 1 183 FX4 1 32W21D Double 32" - marble travertine 1 184 Subtotal: 185 Appliance 186 A1 1 36W31D Side-by-Side - color 10, shiny w 1 187 A2 1 28W27D Dryer (gas) - color 10, shiny w 1 188 A3 1 26W27D Washer - color 10, shiny white 1 189 A4 1 30W26D Elec (medium) - color 10, shiny 1 190 A5 1 36W7D Convection Heater - color 10, s 1 191 Subtotal: 192 Electrical 193 E1 1 wall mount Duplex (low res) 19 194 E2 1 wall mount 220V (low res) 1 195 E3 1 wall mount Single Pole 3 196 E4 1 wall mount Porch Lantern 4 197 E5 1 wall mount Three Way 6 198 E6 1 wall mount Weatherproof 1 199 E7 1 wall mount Electrical Panel 1 200 E8 1 wall mount GFCI 1 201 E9 1 wall mount Half Cone 1 202 E10 1 ceiling mount Smoke Detector 1 203 E11 1 ceiling mount Half Dome 8 204 E12 2 wall mount Duplex (low res) 5 205 E13 2 wall mount Single Pole 3 206 E14 2 ceiling mount Smoke Detector 2 207 E15 2 ceiling mount Half Dome 4 208 Subtotal: 209 Hardware 210 H1 1 utility cab drawer handle 2 211 H2 1 utility cab door handle 13 212 H3 1 utility cab drawer glide 4 213 H4 1 utility cab door hinge 26 214 Subtotal: 215 216 Total: