Code Compliance Research Report CCRR-0153

Similar documents
Code Compliance Research Report CCRR-0106

Code Compliance Research Report CCRR-0185

Code Compliance Research Report CCRR-0187

ATI Evaluation Service A Division of Architectural Testing Certification Services

Code Compliance Research Report CCRR-0176

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

Code Compliance Research Report CCRR-0262

Code Compliance Research Report CCRR-0171

Code Compliance Research Report CCRR-0194

Code Compliance Research Report CCRR-0114

Code Compliance Research Report CCRR-0118

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0213

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0100

Code Compliance Research Report CCRR-0137

Code Compliance Research Report CCRR 0277

ATI Evaluation Service A Division of Architectural Testing Certification Services

Code Compliance Research Report CCRR-0238

Code Compliance Research Report CCRR-0163

Code Compliance Research Report CCRR-0238

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI-ES Code Compliance Research Report

ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125

Code Compliance Research Report CCRR-0163

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI-ES Code Compliance Research Report

Code Compliance Research Report CCRR-0223

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

Code Compliance Research Report CCRR-0101

Code Compliance Research Report CCRR-0257

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

Code Compliance Research Report CCRR 0241

ATI Evaluation Service A Division of Architectural Testing Certification Services

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

Code Compliance Research Report CCRR-0266

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

REPORT HOLDER: HOMELAND VINYL PRODUCTS, INC PINSON VALLEY PARKWAY BIRMINGHAM, ALABAMA EVALUATION SUBJECT:

Code Compliance Research Report CCRR-0234

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER: FYPON, LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING SECTION: PLASTIC RAILINGS REPORT HOLDER:

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

Code Compliance Research Report CCRR-0186

ATI Evaluation Service A Division of Architectural Testing Certification Services

Code Compliance Research Report CCRR 0270

Code Compliance Research Report CCRR-0164

PER See all Pei ES Listings at: Report Owner (Fabricator) Vinyl By Design State Road 15 New Paris, IN 46553

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC RAILINGS SECTION: STRUCTURAL PLASTICS REPORT HOLDER:

ESR-1461 Reissued February 1, 2014 This report is subject to renewal March 1, 2015.

ATI Evaluation Service A Division of Architectural Testing Certification Services #0774

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING SECTION: PLASTIC RAILINGS REPORT HOLDER:

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

Evaluation Report Information USA Vinyl, LLC contact: Joe Eickholt

Section Rigid PVC Railings and Balustrades

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: CPG INTERNATIONAL LLC DBA THE AZEK COMPANY LLC EVALUATION SUBJECT:

Code Compliance Research Report CCRR-0225

REPORT HOLDER: MASTER MARK PLASTICS PRODUCTS 210 AMPE DRIVE PAYNESVILLE, MINNESOTA EVALUATION SUBJECT:

Originally Issued: 12/09/2014 Revised: 10/01/2018 Valid Through: 11/30/ Design:

Code Compliance Research Report CCRR-0208

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX EVALUATION SUBJECT:

Code Compliance Research Report CCRR-0225

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX 2955 LONE OAK DRIVE, SUITE 180 EAGAN, MINNESOTA 55121

ESR-1190 Reissued December 1, 2013 This report is subject to renewal December 1, 2014.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

UL Evaluation Report UL ER Issued: December 10, 2016 Revised: February 22, UL Category Code: ULEV. CSI MasterFormat

Code Compliance Research Report CCRR 0232

** REVISED BY THE CITY OF LOS ANGELES

Approved Manufacturing Locations Fiber Composites, LLC 181 Random Drive New London, NC 28127

Code Compliance Research Report CCRR-0228

Code Compliance Research Report CCRR-0131

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING REPORT HOLDER: UFP VENTURES II, INC.

TEST REPORT. Rendered to: FAIRWAY BUILDING PRODUCTS, LP. For: Solutions Aluminum Guardrail System with Glass Balustrades

ICC-ES Evaluation Report Reissued April 1, 2013 This report is subject to renewal April 1, 2015.

ATI Evaluation Service A Division of Architectural Testing Certification Services

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING REPORT HOLDER: SILCA SYSTEM

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

Trusted ICC ES INC. Evaluation. report, or as to any. ICC-ES Evaluation

ESR-3168 Reissued January 1, 2014 This report is subject to renewal February 1, 2016.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

STRUCTURAL PERFORMANCE TEST REPORT. Rendered to: DIGGER SPECIALITIES, INC. For: 8 ft by 42 in Westbury Style C10 Level Aluminum Guardrail Assembly

WESTERN SPINDLE LLC TEST REPORT

Advantage ICF System Product Information Bulletin

February 1, 2018 PARTIES INTERESTED IN DECK BOARD SPAN RATINGS AND GUARDRAIL SYSTEMS (GUARDS AND HANDRAILS)

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

Code Compliance Research Report CCRR-0205

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

ATI Evaluation Service A Division of Architectural Testing Certification Services

100 Veka Drive Fombell, PA GO4.VEKA

Transcription:

Code Compliance Research Report CCRR-0153 Issue Date: 07-26-2016 Renewal Date: 08-01-2017 Revision Date: 12-20-2016 DIVISION: 06 WOOD, PLASTICS, AND COMPOSITES Section: 06 63 00 Plastic Railings FAIRWAY ARCHITECTURAL RAILING SOLUTIONS 53 EBY CHIQUES ROAD P.O. BOX #37 MOUNT JOY, PA 17552 (800) 598-5245 www.fairwayrailing.com REPORT SUBJECT: V200 Vinyl Railing (aka. Fairway Vinyl Systems): V210 Vinyl Railing (aka. Standard Rail System) V220 Vinyl Railing (aka. Contour Rail System) 1.0 SCOPE OF EVALUATION This research report addresses compliance with the following Codes: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2014 Florida Building Code (FBC) Excluding High Velocity Hurricane Zone (HVHZ) Fairway Vinyl Systems / V200 Vinyl Railing have been evaluated for the following properties: Structural Performance Durability Surface Burning 2.0 USES 2.1. General - Fairway Architectural Railing Solutions vinyl systems are guardrails under the definitions of the referenced codes intended for use on elevated walking areas in buildings and walkways as required by the codes. 2.2. Guardrail Assemblies Railing systems are provided as level guardrails for level walking areas such as decks, balconies and porches, and sloped guardrail for open sides of stairways. 3.0 DESCRIPTION 3.1. Level guardrails with a 36 inch overall installed height are provided in lengths up to 10 feet (120 inches). Guardrails with a 42 inch overall installed height are provided in lengths up to 8 feet (96 inches). See Table 1 Maximum Railing System Size and Code Recognition. 3.2. Stair guardrails are provided in lengths up to 8 feet (96 inches) sloping length with a height up to that corresponding to a 42 inch level rail. See Table 1 Maximum Railing System Size and Code Recognition. 3.3. Materials and Processes - Railings are an assemblage of extruded and molded components utilizing Poly Vinyl Chloride (PVC) material and aluminum reinforcements. Vinyl components are produced in three colors: White, Tan, and Khaki. All systems consist of the following components: 3.3.1. The top and bottom rails are extruded PVC profiles of various styles. 3.3.2. Balusters are extruded PVC profiles in various dimensions. Some extrusions are reshaped by a thermoform process to simulate a turned spindle design. See Table 4 for a list of styles. 3.3.3. An extruded aluminum (6105-T5 or 6005-T5) insert provides reinforcement for the top and bottom rails. 3.3.4. Top and bottom rails are connected to posts with molded plastic brackets (See Figure 8) that are secured to the supports with stainless steel screws. 3.3.5. Supports - Railing systems are attached to conventional wood supports which are outside the scope of this report. A PVC post sleeve that is nonstructural is provided as a cladding over conventional 4x4 wood posts. 4.0 PERFORMANCE CHARACTERISTICS 4.1. The railing systems described in this report have demonstrated the capacity to resist the design loadings for Guardrails specified in Chapter 16 of the IBC when tested in accordance with ICC-ES AC174.

Code Compliance Research Report Page 2 of 10 4.2. Structural performance has been demonstrated for a temperature range from -20 F to 125 F. 4.3. Materials used are deemed equivalent to preservative treated or naturally durable wood for resistance to weathering effects, decay, and attack from termites. 4.4. The PVC materials used have a flame spread index not exceeding 200 when tested according to ASTM E 84-09. The referenced criteria, AC174, requires a flame spread index not exceeding 200. 5.0 INSTALLATION Fairway Vinyl Systems / V200 Vinyl Railing must be installed in accordance with the manufacturer s published installation instructions, the applicable Code and this Research Report. The manufacturer s published installation instructions and this Research Report must be strictly adhered to, and a copy of the instructions must be available on the jobsite during installation. 5.1. Railing assemblies consist of top and bottom rails with pre-routed holes to receive balusters. Aluminum railing reinforcements are inserted in the rails during assembly as specified for the type and length of railing (see Table 2 and Table 3). 5.2. Railings attached to wood supports with molded PVC brackets utilize stainless steel "Hi-Lo" wood screws for anchorage. The wood in the supporting structure shall have a specific gravity of 0.50 or greater (Southern Yellow Pine or better) and a minimum thickness to allow full penetration of the bracket mounting screws. Bracket attachment shall be in accordance with Table 5. 5.2.1. Where required by the building official, engineering calculations and details shall be provided. The calculations shall verify that the anchorage complies with the building code for the type and condition of the supporting construction. 5.2.2. Compatibility of fasteners and other installation hardware with the supporting construction including treated wood is not within the scope of this report. 6.0 SUPPORTING EVIDENCE 6.1. Manufacturer's drawings and installation instructions. 6.2. Reports of testing and engineering analysis demonstrating compliance with the performance requirements of ICC-ES AC174, Acceptance Criteria for Deck Board Span Ratings and Guardrail Systems (Guards and Handrails), revised February 2014, and ASTM D 7032-08, Standard Specification for Establishing Performance Ratings for Wood-Plastic Composite Deck Boards and Guardrail Systems (Guards or Handrails). 6.3. Documentation of an Intertek approved quality control system for the manufacturing of products recognized in this report. 7.0 CONDITIONS OF USE The Fairway Vinyl Systems / V200 Vinyl Railing described in this Research Report comply with, or is a suitable alternative to what is specified in those Codes listed in Sections 1.0 and 2.0 of this report, subject to the following conditions: 7.1. Installation must comply with this Research Report, the manufacturer s published installation instructions and the applicable Code. In the event of a conflict between the manufacturer s instructions and this report, this report governs. 7.2. Fairway Architectural Railing Solutions V200 vinyl rails are manufactured in Mount Joy, PA and York, NE in accordance with the manufacturer's approved quality control system with inspections by Intertek. 7.3. Guardrails recognized in this report and regulated by the IBC, IRC, or FBC are limited to exterior use in all construction types where wood is permitted in accordance with Section 1406.3 of the IBC and FBC and in One- and Two-Family Dwellings regulated by the IRC. Level rail systems over 8 ft long are further limited to use in One- and Two-Family Dwellings (IRC) as indicated in Table 1. 7.4. Conventional wood guardrail supports are not within the scope of this report and are subject to evaluation and approval by the building official. Supports must satisfy the design load requirements specified in Chapter 16 of the IBC and must provide suitable material for anchorage of the rail brackets. Where required by the building official, engineering calculations and details shall be provided. 7.5. Compatibility of fasteners, post mount brackets, and other metallic components with the supporting

Code Compliance Research Report Page 3 of 10 structure, including chemically treated wood, is not within the scope of this report. 8.0 IDENTIFICATION The Fairway Vinyl Systems / V200 Vinyl Railing described in this Research Report are identified by a marking bearing the report holder s name (Fairway Architectural Railing Solutions.); the Intertek Mark and the Code Compliance Research Report number (CCRR-0153); and where applicable (for rails over 8 ft long, as shown in Table 1), the label shall include the phrase: "For Use in One- and Two-Family Dwellings Only"; and the following statement: See CCRR-0153- at https://whdirectory.intertek.com for uses and performance levels. 9.0 CODE COMPLIANCE RESEARCH REPORT USE 9.1. Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 9.2. Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product by Intertek. 9.3. Reference to the Intertek website address: whdirectory.intertek.com is recommended to ascertain the current version and status of this report. TABLE 1 MAXIMUM RAILING SYSTEM SIZE AND CODE RECOGNITION STYLE CODE RECOGNITION Maximum Railing Size (Length x Height) 1 IBC and FBC IRC and FBC-Residential 2 Standard Rail / V210 Vinyl Railing Contour Rail / V220 Vinyl Railing 8' x 42" Level 87-1/2" x 42" Stair 8' x 42" Level 91-3/4" x 42" Stair 10' x 42" Level 87-1/2" x 42" Stair 10' x 42" Level 91-3/4" x 42" Stair 1 Railing lengths are clear length between supports. Railing height is installed height from walking surface to top of top rail. Minimum bottom rail clearance is 2". 2 The use of this product shall be limited to exterior use as a guardrail system for balconies and porches for one- and two-family dwellings of Type V-B (IBC) construction and structures constructed in accordance with the IRC. This Code Compliance Research Report ( Report ) is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.

Code Compliance Research Report Page 4 of 10 TABLE 2 - LEVEL RAILING SYSTEMS DESCRIPTIONS STYLE LEVEL RAILING SYTEM COMPONENTS (See Table 4 for available Balusters) RAILS BRACKETS Standard Rail / V210 Vinyl Railing Contour Rail / V220 Vinyl Railing Top: 2x3-1/2" Standard Rail / V210 Vinyl Railing with Alum "H" channel Bottom: 2x3-1/2" Standard Rail / V210 Vinyl Railing (Alum "H" Channel in lengths exceeding 8 feet.) Top: Contour Rail / V220 Vinyl Railing with Contour Alum insert Bottom: 2x3-1/2" STD Rail (Alum "H" Channel in lengths exceeding 8 feet.) Top: OEM Bottom: OEM Top: Two-Piece Contoured / V220 Vinyl Railing Bottom: OEM TABLE 3 STAIR RAILING SYSTEM DESCRIPTIONS STYLE STAIR RAILING SYSTEM COMPONENTS (See Table 4 for available balusters) RAILS BRACKETS Standard Rail / V210 Vinyl Railing Contour Rail / V220 Vinyl Railing Top: 2x3-1/2" Standard Rail / V210 Vinyl Railing with Alum "H" channel Bottom: 2x3-1/2" STD Rail with Alum "H" Channel Top: Contour Rail / V220 Vinyl Railing with Contour Alum insert Bottom: 2x3-1/2" Standard Rail with Alum "H" Channel Top & Bottom: OEM Top: Contour / V220 Vinyl Railing Stair Bracket Bottom: OEM TABLE 4 - BALUSTERS BALUSTER STYLE 3/4" x 1-1/2" PVC Baluster 1-1/4" Square PVC Baluster 1-3/8" Square PVC Baluster 1" x 2" PVC Baluster

Code Compliance Research Report Page 5 of 10 TABLE 5 RAIL BRACKET FASTENING SCHEDULE RAIL BRACKET COMBINATION 2" x 3-1/2" Standard Rail / V210 Vinyl Railing with OEM Bracket 2-1/4" x 3" Contour Rail / V220 Vinyl Railing w/ Two-Piece Contour Bracket 2-1/4" x 3" Contour Rail / V220 Vinyl Railing w/ Contoured Stair Bracket BRACKET TO POST (4) #12 x 1-1/4" Stainless Steel Screws (4) #10 x 2" Stainless Steel Screws (2) #10 x 4" Stainless Steel Screws RAIL TO BRACKET (2) #10 x 1" self-tapping screws (2) #10 x 1" self-tapping screws (2) #10 x 1" self-tapping screws 2" x 3.5" Standard Rail / V210 Vinyl Railing 2.25" x 3" Small Contour Rail / V220 Vinyl Railing 4" x 4" Standard / V210 Vinyl Railing Post FIGURE 1 PVC RAIL AND POST PROFILE DRAWINGS

Code Compliance Research Report Page 6 of 10 FIGURE 2 2.25" X 3.00" CONTOUR RAIL / V220 VINYL RALING ALUMINUM INSERT FIGURE 3-2.00" X 3.50" STANDARD RAIL / V210 VINYL RAILING ALUMINUM H-CHANNEL INSERT

Code Compliance Research Report Page 7 of 10 1" x 2" Baluster 0.75" x 1.5" Baluster 1.375" x 1.375" Baluster 1.25" x 1.25" Baluster FIGURE 4 BALUSTER PROFILES

Code Compliance Research Report Page 8 of 10 FIGURE 5 2 X 3-1/2 STANDARD RAIL / V210 VINYL RAILING (LEVEL AND STAIR) Bottom rail reinforcement not shown for level rail. See Table 2 for requirement.

Code Compliance Research Report Page 9 of 10 FIGURE 6 - CONTOUR RAIL / V220 VINYL RALING (LEVEL AND STAIR) Bottom rail reinforcement not shown for level rail. See Table 2 for requirement.

Code Compliance Research Report Page 10 of 10 2" x 3.5" OEM Base Contour / V220 Vinyl Railing Stair Bracket1 Contour / V220 Vinyl Railing Bracket and Trim FIGURE 7 - PLASTIC BRACKETS : 1 Contour brackets are field cut for a flush fit to the supporting surface with an angle corresponding to the stair slope. The end cut shall be limited to providing the required angle and shall not reduce the overall length of the bracket.