A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

Panelized Linear Walls Installation Guide

WoodTrends Acoustical Wood Ceiling System BASIC Specification

WOODFIT ACOUSTICS PERFORATED CEILING SYSTEM P007 ARCHICTECTURAL SPECIFICATION

Ceiling Tiles C200B - Specification

Curvalon and Curvatone Ceilings Installation Guide

Geometrik Manufacturing Inc.

Geometrik Manufacturing Inc.

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Section Wood Veneer Ceiling Planks Linear

Construction Standards PAGE

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

Section SoundPly LR M25 Acoustic Ceiling Panels

EXTERIOR PLANK SERIES SPECIFICATION DATA

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Section Wood Grille Ceiling Panels

Guide Specifications Section Wood Ceiling Coffers

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

SECTION COMPOSITE CORE ACOUSTICAL PANEL CEILINGS. Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

Section Wood Veneer Ceiling Tiles Micro Perforated

Endure 900 Suspended Ceiling Installation Guide

Technical Data VARIABLES

Technical Data VARIABLES

Technical Data VARIABLES

OPTIMA Vector Plank Installation Instructions

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

SECTION ACOUSTICAL CEILINGS

SECTION ACOUSTICAL PANEL CEILINGS

Optima Vector Plank. Installation Instructions. Ceiling

SECTION / STC 52 METAL SOUND CONTROL DOORS

Technical Data VARIABLES

Technical Data VARIABLES

DiSorb Diffuser Product Specifications Section Sound Diffuser-Absorber for Ceilings and Walls (DiSorb Diffuser-Absorber)

Marlite Guide Specification 2/24/2017 Surface Systems - MAP375 System SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

METALWORKS Torsion Spring

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)

Student Services & Classroom Addition

Section SoundPly RF M25 Acoustic Wall Panels

SECTION LINEAR METAL CEILINGS

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Architectural Components Group, Inc.

LINEAR METAL CEILINGS Section

SECTION AXIOM INDIRECT FIELD LIGHT COVE PERIMETER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION GYPSUM BOARD ASSEMBLIES

TECHNICAL DATA. I. Description of Components. Product Styles. Wood Selection. Wood Finishes. V. Fire Retardancy. LEED & Green Building Standards

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Optima Vector Ultima Vector

Framed Decorative Panel Systems

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

Soundmaster & Modernfold TECHNICAL DATA

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

A. Section includes Sprayed Fire-Resistive Materials: (SFRM) A. Pre-Installation Conference: Conduct conference at Project Site.

1. This addendum contains the specifications for Acoustical Ceilings: public areas Lobby, Breakfast Room, etc. and not used on all doors.

A. Meet at Project site <insert number> days before starting installation.

SECTION DRYWALL GRID LINEAR LIGHTING INTEGRATION

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

***************************************************************************************************************

ARMSTRONG SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY OF ITS GUIDE SPECIFICATIONS. SECTION PERIMETER TRANSITION SYSTEM

SECTION STILE AND RAIL WOOD DOORS

SECTION FLUSH WOOD VENEER DOORS

GLASS WALL SPECIFICATIONS

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

SECTION (09800) - Suspended Acoustic Baffles. This Section is based on TECHLITE Accent Linear Ceiling Baffles.

SECTION Axiom Roller Shade Integration

CONCRETE TILE PAVERS

GLASS WALL SPECIFICATIONS

Proposed Specification Section FLUSH WOOD VENEER DOORS

SECTION SECURITY PROTECTION PART 1 GENERAL

SECTION INTUMESCENT MASTIC FIREPROOFING

SECTIONAL OVERHEAD DOORS SECTION SECTIONAL OVERHEAD DOORS PART 1 GENERAL

ACOUSTICAL WALL TREATMENT SECTION 09840

SECTION ACOUSTICAL TILE. *(Filed Sub-Bid Required) 1.00 TIME, MANNER AND REQUIREMENTS FOR SUBMITTING SUB-BIDS

GLASS WALL SPECIFICATIONS

SECTION GYPSUM BOARD SYSTEM

Guideline Specifications GORDON MARQUIS LINEAR CEILING PANEL SYSTEMS

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

PRODUCT SPECIFICATIONS

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ACOUSTICAL PANEL CEILINGS. A. Section includes acoustical panels and exposed suspension systems for ceilings.

SECTION SOUND CONTROL DOORS

BASICS Direct-Attach Ceiling Panels

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION GYPSUM BOARD SYSTEM

SECTION RESILIENT SHEET FLOORING

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS

Transcription:

12/6/2012 RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS PART 1 - GENERAL A. The Wood Square Suspended Ceiling Systems covered by this specification shall be the products of the Rulon International,, 2000 Ring Way Road,. Phone: 800-227-8566,,,. B. The General Conditions and the requirements of Division 1 of the Specifications shall apply to all work hereunder. C. All work shall be performed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative. 1.01 SCOPE A. Rulon International shall furnish all Wood Squares and specified matching trims. The suspension system shall be in accordance with drawings, and supplied by others. 1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION A. Suspension systems and components for ceilings other than manufacturer's Wood Square Suspended Ceiling Systems shall not be included. 1.03 QUALITY ASSURANCE A. Installer Qualifications: Installer shall be a firm with not less than two (2) years of successful experience in installation of suspended wood ceilings of similar requirements to this project. The installer shall be acceptable to the architect, manufacturer, and owner's representative. B. Fire Performance Characteristics: When specified as "Fire Resistant", Rulon Wood Squares shall conform to Class 1, or A flame spread rating, when tested according to ASTM E-84. C. Environmental Standards: When required, veneer panel components shall originate from well managed forests as certified by accredited and recognized industry certifying organizations. - 1 -

RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATION 1.04 PROJECT CONDITIONS A. Installation shall be done only when the temperature and humidity closely approximate the interior conditions that will exist when the building is occupied. The heating and cooling systems shall be operating before, during, and after installation, with the humidity of the interior spaces maintained between 25% and 55%, temperature between 60 to 90 degrees F. B. It is important that plenums have proper ventilation, especially in high moisture areas. There shall be no excessive build up of heat in the ceiling areas. C. Prior to the start of installation, all exterior windows and doors are to be in place, glazed, and weather-stripped. The roof is to be watertight, and all wet trades' work is to be completed, and thoroughly dry. D. Mechanical, electrical, and other utility service installations above the ceiling plane shall have been completed. No materials should rest against, or wrap around, the ceiling suspension components or connecting hangers. 1.05 COORDINATION OF WORK A. The layout and installation of the Wood Square Suspended Ceiling System and suspension components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components. 1.06 SUBMITTALS A. Product Data: Rulon International shall provide product specifications for all ceiling materials supplied. B. Shop Drawings: When required, Rulon International shall supply shop drawings showing Wood Square locations, and placement of hangers, carriers, and other details deemed pertinent to proper installation. C. Samples: A 12" (305mm) wide x 12" (305mm) long wood sample with designated finishes shall be submitted for approval. 1.07 DELIVERY, STORAGE, AND HANDLING A. The Wood Squares shall be delivered to the project site in original, unopened packages. B. The Wood Squares shall be stored flat and level in a fully enclosed space. For a minimum of seventy-two (72) hours immediately prior to ceiling installation, the Wood Squares shall be stored in the room in which they will be installed. The temperature and humidity of the room shall closely approximate those conditions that will exist when the building is occupied. The Wood Squares shall be stored off the floor. - 2 -

RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATION C. Care in handling must be exercised to avoid damage. 1.08 WARRANTIES A. Manufacturer: All materials supplied by the ceiling manufacturer shall be guaranteed against manufacturing defects for one (1) year. Because of differing site conditions, wood stains and colorings can vary with age and shall be excluded from this warranty. B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work PART 2 - PRODUCT 2.01 WOOD SQUARES A. The Wood Squares shall be manufactured by Rulon International, St.Augustine, Florida, PH-1-800-227-8566,. The Rulon Wood Squares will be made with a [veneer species] face veneer, [veneer cut] [veneer match], applied to a 3/4 (19mm) thick core material. The edge treatment on the Wood Square panels shall be the [selected style]. The standard Wood Square panel shall be 3/4" (19mm) thick and 2' (610mm) x 2' (610mm) (nominal). Wood is a natural product that will undergo changes with variations in the environment. Therefore, all dimension tolerances shall be ± 1/8" (3mm). 2.02 SUSPENSION SYSTEM A. A 2' (610mm) x 2' (610mm) grid system shall be fabricated to support the Wood Squares, using [15/16" (24mm)] or [9/16 (14mm)] heavy-duty T-rail suspension (supplied by others). 2.03 EDGES, BORDERS, AND PERIMETER TRIMS A. Edges, borders, and perimeter trims, shall be designated by specifier in accordance with standard design details available. All wood products specified shall be supplied by the ceiling manufacturer. 2.04 FINISHES AND COLORS A. The Wood Square face surface (and edges, if necessary) shall be factory finished with a clear or custom stain as selected by the Architect. A clear finish is applied to the back side of panels. Wood is a natural product with variations in grain, texture and color often ranging from light to dark thereby affecting the surface look. Product finishes shall be stain or sealer coats spray applied to a smooth sanded surface. - 3 -

RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATION PART 3 - EXECUTION 3.01 PREPARATION A. Ceiling Layout: The contractor shall measure ceiling areas and establish layout of hangers and T-rails, in accordance with installation instructions. B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field. 3.02 INSTALLATION A. General: The contractor shall install materials to comply with applicable regulations and industry standards. B. Perimeter: Using a leveling device, the contractor shall lay out and install perimeter trim as specified. C. Suspension: The T-rail supports shall be suspended and leveled in the appropriate pattern determined by design. Specified wood trims shall be attached, where indicated. D. Squares: The Wood Squares shall be inserted into the grid system - using care to orient for proper grain directions and openings for penetrations. 3.03 ADJUSTMENT CLEANING AND REPAIR A. The contractor shall make final adjustment to level or contours. B. Upon completion of ceiling installation, all Wood Squares shall be cleaned free of dirt, dust, grease, oils, and fingerprints. C. All work which cannot be successfully cleaned and repaired shall be removed and replaced. 3.04 INSPECTION A. Upon the completion of ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that work was performed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner or to ceiling manufacturer. - 4 -

10/3/2012 RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS FOR SIDE SLOT SUSPENSION ARCHITECTURAL SPECIFICATIONS PART 1 - GENERAL A. The Wood Square Suspended Ceiling Systems covered by this specification shall be the products of the Rulon International,, 2000 Ring Way Road,. Phone: 800-227-8566,,,. B. The General Conditions and the requirements of Division 1 of the Specifications shall apply to all work hereunder. C. All work shall be performed in accordance with the manufacturer's instructions, and in a manner satisfactory to the owner's representative. 1.01 SCOPE A. Rulon International shall furnish all Wood Square Ceiling Panels and specified matching trims. The suspension system shall be in accordance with drawings, and supplied by others. 1.02 RELATED WORK NOT INCLUDED UNDER THIS SECTION A. Suspension systems and components for ceilings other than manufacturer's Wood Square Suspended Ceiling Systems shall not be included. 1.03 QUALITY ASSURANCE A. Installer Qualifications: Installer shall be a firm with not less than two (2) years of successful experience in installation of suspended wood ceilings of similar requirements to this project. The installer shall be acceptable to the architect, manufacturer, and owner's representative. B. Fire Performance Characteristics: When specified as "Fire Resistant", Rulon Wood Squares shall conform to Class 1, or A flame spread rating, when tested according to ASTM E-84. C. Environmental Standards: When required, veneer panel components shall originate from well managed forests as certified by accredited and recognized industry certifying organizations. - 1 -

RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATION 1.04 PROJECT CONDITIONS A. Installation shall be done only when the temperature and humidity closely approximate the interior conditions that will exist when the building is occupied. The heating and cooling systems shall be operating before, during, and after installation, with the humidity of the interior spaces maintained between 25% and 55%, temperature between 60 to 90 degrees F. B. It is important that plenums have proper ventilation, especially in high moisture areas. There shall be no excessive build up of heat in the ceiling areas. C. Prior to the start of installation, all exterior windows and doors are to be in place, glazed, and weather-stripped. The roof is to be watertight, and all wet trades' work is to be completed, and thoroughly dry. D. Mechanical, electrical, and other utility service installations above the ceiling plane shall have been completed. No materials should rest against, or wrap around, the ceiling suspension components or connecting hangers. 1.05 COORDINATION OF WORK A. The layout and installation of the Wood Square Suspended Ceiling Systems and suspension components shall be coordinated with other work penetrating the ceiling. This includes light fixtures, HVAC equipment, and fire suppression system components. 1.06 SUBMITTALS A. Product Data: Rulon International shall provide product specifications for all ceiling materials supplied. B. Shop Drawings: When required, Rulon International shall supply shop drawings showing Wood Square Suspended Ceiling Panel locations, and placement of hangers, carriers, and other details deemed pertinent to proper installation. C. Samples: A 12" (305mm) wide x 12" (305mm) long wood sample with designated finishes shall be submitted for approval. 1.07 DELIVERY, STORAGE, AND HANDLING A. The Wood Square Suspended Ceiling Panels shall be delivered to the project site in original, unopened packages. B. The Wood Square Suspended Ceiling Panels shall be stored flat and level in a fully enclosed space. For a minimum of seventy-two (72) hours immediately prior to ceiling installation, the Ceiling Panels shall be stored in the room in which they will be installed. The temperature and humidity of the room shall closely approximate those conditions that will exist when the building is occupied. The Ceiling Panels shall be stored off the floor. - 2 -

RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATION C. Care in handling must be exercised to avoid damage. 1.08 WARRANTIES A. Manufacturer: All materials supplied by the ceiling manufacturer shall be guaranteed against manufacturing defects for one (1) year. Because of differing site conditions, wood stains and colorings can vary with age and shall be excluded from this warranty. B. Contractor: All work shall be guaranteed for one (1) year from final acceptance of completed work PART 2 - PRODUCT 2.01 WOOD SQUARES A. The Wood Squares shall be manufactured by Rulon International, St.Augustine, Florida, PH-1-800-227-8566,. The Rulon Wood Squares will be made with a [veneer species] face veneer, [veneer cut] [veneer match], applied to a 3/4 (19mm) thick core material. Panel edges are to be edge banded in matching wood veneer and finish. The back of the Ceiling Panel is to be faced with a balance veneer. The edge treatment on the Ceiling Panels shall have a factory-applied custom cut to allow for downward ceiling panel access. The standard Wood Square Ceiling Panel shall be 3/4" (19mm) thick and 2' (610mm) x 2' (610mm) (nominal). Wood is a natural product that will undergo changes with variations in the environment. Therefore, all dimension tolerances shall be ± 1/8" (3mm). 2.02 SUSPENSION SYSTEM A. A 2' (610mm) x 2' (610mm) grid system shall be fabricated to support the Wood Square Ceiling Panels, using 15/16" (19mm) heavy-duty T-rail suspension (supplied by others). 2.03 EDGES, BORDERS, AND PERIMETER TRIMS A. Edges, borders, and perimeter trims, shall be designated by specifier in accordance with standard design details available. All wood products specified shall be supplied by the ceiling manufacturer. - 3 -

RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATION 2.04 FINISHES AND COLORS A. The Wood Square face surface (and edges, if necessary) shall be factory finished with a clear or custom stain as selected by the Architect. A clear finish is applied to the back side of panels. Wood is a natural product with variations in grain, texture and color often ranging from light to dark thereby affecting the surface look. Product finishes shall be stain or sealer coats spray applied to a smooth sanded surface. PART 3 - EXECUTION 3.01 PREPARATION A. Ceiling Layout: The contractor shall measure ceiling areas and establish layout of hangers and T-rails, in accordance with installation instructions. B. Coordination: The contractor shall furnish the layout for supports that shall be installed for suspension of ceilings. He shall furnish concrete inserts, steel deck hanger clips, or similar devices for installation, in time to coordinate the work. The contractor shall coordinate with other trades the location of devices which will penetrate the Ceiling Panels or interfere with the installation. Recessed or surface devices located within the ceiling panels are to be located and cut in the field. 3.02 INSTALLATION A. General: The contractor shall install materials to comply with applicable regulations and industry standards. B. Perimeter: Using a leveling device, the contractor shall lay out and install perimeter trim as specified. C. Suspension: The T-rail supports shall be suspended and leveled in the appropriate pattern determined by design. Specified wood trims shall be attached, where indicated. D. Ceiling Panels: The Wood Square Ceiling Panels shall be suspended by the grid system by sliding the leading edge stepped kerf onto the grid system, lifting the trailing edge to rest on the opposite grid flange, and dropping the panel onto position, allowing the panel to rest on the upper stepped kerf of the leading edge. Reversed tegular edges along the remaining two sides partially conceal the flanking grid flanges. 3.03 ADJUSTMENT CLEANING AND REPAIR A. The contractor shall make final adjustment to level or contours. - 4 -

RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATION B. Upon completion of ceiling installation, all Wood Square Ceiling Panels shall be cleaned free of dirt, dust, grease, oils, and fingerprints. C. All work which cannot be successfully cleaned and repaired shall be removed and replaced. 3.04 INSPECTION A. Upon the completion of ceiling installation, the owner's representative shall inspect all finished surfaces to ensure that work was performed in a manner satisfactory to the owner. Any deficiencies in the installed ceiling shall be corrected by the contractor at no additional cost to the owner or to ceiling manufacturer. - 5 -

23 3 4" [603 mm] BALANCING VENEER 3 4 " [19 mm] CORE BOARD FACE VENEER HEAVY-DUTY 15/16" [24 mm] T-RAIL 24" [610 mm] O.C. (NOT BY RULON) Wood Square - Lay-in Style - 15 16" Grid AUG/11/2016 TA SLXA0001

23 3 4" [603 mm] BALANCING VENEER 3 4 " [19 mm] CORE BOARD FACE VENEER HEAVY-DUTY 9/16" [14 mm] T-RAIL 24" [610 mm] O.C. (NOT BY RULON) Wood Square - Lay-in Style - 9 16" Grid AUG/11/2016 TA SLXB0001

BALANCING VENEER 23 3 4" [603 mm] HEAVY-DUTY 15/16" [24 mm] T-RAIL 24" [610 mm] O.C. (NOT BY RULON) 3 4 " [19 mm] CORE BOARD 1" [25 mm] 23" [584 mm] CORE FINISHED AND SEALED FACE VENEER Wood Square - Standard Tegular Style - 15 16" Grid AUG/11/2016 TA STXA0002

BALANCING VENEER 23 3 4" [603 mm] HEAVY-DUTY 9/16" [14 mm] T-RAIL 24" [610 mm] O.C. (NOT BY RULON) 3 4 " [19 mm] CORE BOARD 5 8 " [15 mm] 23 3 8" [594 mm] CORE FINISHED AND SEALED FACE VENEER Wood Square - Standard Tegular Style - 9 16" Grid AUG/11/2016 TA STXB0002

23" [584 mm] BALANCING VENEER 3 4 " [19 mm] CORE BOARD 1" [25 mm] VENEER EDGE BANDING FACE VENEER HEAVY-DUTY 15/16" [34 mm] T-RAIL 24" [610 mm] O.C. (NOT BY RULON) Wood Square - Edge Banded Full Depth Tegular Style - 15 16" Grid AUG/11/2016 TA STFA0002

23 3 8" [594 mm] BALANCING VENEER 3 4 " [19 mm] CORE BOARD 5 8 " [16 mm] VENEER EDGE BANDING FACE VENEER HEAVY-DUTY 9/16" [14 mm] T-RAIL 24" [610 mm] O.C. (NOT BY RULON) Wood Square - Edge Banded Full Depth Tegular Style - 9 16" Grid AUG/11/2016 TA STFB0002

23" [584 mm] BALANCING VENEER 3 4 " [19 mm] CORE BOARD 1" [25 mm] VENEER EDGE BANDING FACE VENEER HEAVY-DUTY 15/16" [24 mm] T-RAIL 24" [610 mm] O.C. (NOT BY RULON) Wood Square - Edge Banded Partial Depth Tegular Style - 15 16" Grid AUG/11/2016 TA STPA0002

23 3 8" [594 mm] BALANCING VENEER 3 4 " [19 mm] CORE BOARD 5 8 " [16 mm] VENEER EDGE BANDING FACE VENEER HEAVY-DUTY 9/16" [14 mm] T-RAIL 24" [610 mm]o.c. (NOT BY RULON) Wood Square - Edge Banded Partial Depth Tegular Style - 9 16" Grid AUG/11/2016 TA STPB0002

BALANCING VENEER HEAVY-DUTY 15/16" [24 mm] T-RAIL 24" [610 mm] O.C. (NOT BY RULON) 3 4 " [19 mm] CORE BOARD 3 8 " [10 mm] EDGE BANDED (TYP) 23 5 8" [600 mm] FACE VENEER Wood Square - Side Slot Style - 15 16" Grid AUG/11/2016 TDA SSXA0003

STEP 1: ENGAGE NORTH EDGE STEP 2: SLIDE PANEL TO LEFT TO ALLOW SOUTH EDGE TO CLEAR NORTH-SOUTH SIDE SLOT EDGES STEP 3: SLIDE PANEL TO RIGHT TO LOCK PANEL ONTO GRID EAST-WEST REVERSE TEGULAR EDGES Wood Square - Side Slot Style - Panel Installation Detail SEP/13/2012 TDA SSXA0004

BALANCING VENEER HEAVY-DUTY 15/16" [24 mm] T-RAIL 24" O.C. (NOT BY RULON) CORE BOARD 45 2" [51 mm] 1 8 " [3 mm] COFFERED EDGE FACE VENEER 1 8 " [3 mm] Wood Square - Coffered Style - 15 16" Grid SEP/13/2012 TA SCXA0005

COFFERED PANEL (TYP) QUARTERED DIAGONAL QUARTERED SQUARE PLAIN FACE Wood Square - Coffered Style - Face Details SEP/13/2012 TA SCXA0006

WOOD SQUARE VENEER (STANDARD TEGULAR STYLE SHOWN) HEAVY-DUTY 15/16" [24 mm] T-GRID (NOT BY RULON) Wood Square - Isometric View SEP/13/2012 TA STXA0007