EXPRESS PERMIT INFORMATION

Similar documents
BUILDING & INSPECTIONS DIVISION 200 East Wood Street Palatine, IL Telephone (847)

1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS)

BUILDING & INSPECTIONS DIVISION 200 East Wood Street Palatine, IL Telephone (847)

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax:

Building Department HOMEOWNERS MANUAL

Residential Miscellaneous Permits

ATTACHED/DETACHED GARAGE BUILDING PERMIT APPLICATION

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507)

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507)

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

$ Plan Review Fee when Permit Application is submitted SHED BUILDING PERMIT APPLICATION. Application Date / /

The following are exceptions to the use regulations of the district regulations of this ordinance.

CITY OF KIRKWOOD SINGLE FAMILY SITE PLAN WORKSHEET

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

FENCES. This hand out is for REFERENCE ONLY. For more details see specific code sections.

Fence and Wall Requirements

RESIDENTIAL BUILDING PLAN REQUIREMENTS

Residential Decks. NOTE: If you are in a development with a 2. Deck Plan (see below)

C ITY OF D ARIEN Community Development Department 1702 Plainfield Road Phone: (630) Fax: (630)

RESIDENTIAL DESIGN GUIDELINES FOR BENT TREE OF ROGERS

COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS

SECTION R-MH - MANUFACTURED HOUSING RESIDENTIAL DISTRICT.

CITY OF HILSHIRE VILLAGE SWIMMING POOL PLAN SUBMITTAL CHECK LIST ADDRESS: DATE:

Section 7: Specifications

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

2003 International Residential Building Code

RESIDENTIAL GARAGE AND DRIVEWAY

Building a Wood Deck, Gazebo, or Pergola

Definitions. The following words and phrases, when used in this article, shall have the following meanings respectively ascribed to them:

FENCE PERMIT APPLICATION

Building Regulations; Construction 11

RESIDENTIAL DECK INFOREMATION SHEETS

ACCESSORY STRUCTURES (Garages/Sheds) BUILDING AND ZONING REQUIREMENTS (REVISED 4/21/16)

Section , Article 4 of the Zoning Ordinance December 14, 2012 Page 1 of 8

Oregon Building Officials Association

The Homeowner s Building Application Checklist for Constructing a Residential Addition

Residential Zoning Rules

Basement Build-Out Guidelines

THE CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO TELEPHONE: (440) FAX: (440) Building Department

Single Family Residential Building Permit Questions & Answers

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

Driveways and Other Concrete Slabs

One and Two Family Additions

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

Solar Photovoltaic System Permit

CHAPTER 4 FENCE REGULATIONS

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements

LakeRidge Subdivision Design / Architectural Standards

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

Residential Accessory Structures & Room Additions

General Requirements for Mobile Homes

City of St. Peters Residential Deck Guide

PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST

Borough of Doylestown Building and Zoning Department

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

The developer / builder desires to follow the Design Guidelines and Design Features as listed below in lieu of the Basic Standards.

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following:

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

LINWOOD PARK BUILDING REGULATIONS

CITY OF LA MARQUE Gateway to the Gulf st St., La Marque, TX (409) Fax: (409)

Building Permit Application- Residential Community Development Department 27 Riverside Rd. Riverside, IL P: (708) F: (708)

Wildwood Home Owners Association Architectural Review Board Guidelines

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

VILLAGE OF NORTHFIELD (847) BUILDING CONSTRUCTION PERMIT SUBMISSION LIST

Fence Requirements Permits and Inspections Division 151 W Church Street, Lewisville, Texas Phone: Fence Requirements

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER'S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

COUNTY OF NEVADA BUILDING DEPARTMENT POLICIES

MINIMUM REQUIREMENTS FOR CONSTRUCTION PLANS, GRADING AND/OR DRAINAGE PLANS, LOW IMPACT DEVELOPMENT PLANS, AND WATER EFFICIENT LANDSCAPE PLANS

CHAPTER 4. FENCE REGULATIONS (Ordinance No , 07/26/2011)

REGULATIONS FOR RESIDENTIAL OPEN WOOD DECKS

meters (16 Inches) Transportation (T)

RESIDENTIAL ADDITION OR ALTERATION PERMIT REQUIREMENTS

Town of Kingsville. Building Department

CITY OF FATE SINGLE FAMILY BUILDING PERMIT PACKET. Adopted Codes:

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

Chapter 8 MINIMUM CONSTRUCTION STANDARDS

City of Friendswood Community Development 910 South Friendswood Drive Friendswood, Texas 77546

EXHIBIT "B-1" DESIGN GUIDELINES SUBDIVISION DESIGN GUIDELINES FOR MELTON RIDGE

DECK CONSTRUCTION REQUIREMENTS

Accessory Building/Detached Building Permit

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits

VILLAGE OF SHAWNEE HILLS 9484 Dublin Rd. Shawnee Hills, Ohio Phone Fax

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

RESIDENTIAL ACCESSORY BUILDING SETBACKS. April 17, 2014 Staff Memo

RESIDENTIAL DEVELOPMENT GUIDELINES (RF)

PATIOS, STOOPS and PRIVATE WALKWAYS. This hand out is for REFERENCE ONLY. For more details see specific code sections.

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

20 North Main Alpine, UT (Phone) (Fax) SITE PLAN

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

If a new residence s electrical service is not located within 200 feet of existing

Village of Algonquin

1. Complete Building Permit Application forms on page 2. Include septic system design approval from the Washington County Health Department.

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

City of Santa Monica Building and Safety Division

ZONING CLEARANCE PLAN REVIEW CHECKLIST. Based on the Revised Town of Carefree Zoning Ordinance

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES

Transcription:

VILLAGE OF PALATINE DIVISION OF BUILDING PERMITS AND INSPECTIONS 200 East Wood Street Palatine, IL 60067-5339 Telephone (847) 359-9042 Fax (847) 776-4733 www.palatine.il.us EXPRESS PERMIT INFORMATION ASPHALT DRIVEWAY CONSTRUCTION REQUIREMENTS: Asphalt driveways shall be paved with at least 1-1/2 inches of plant mixed asphalt. Asphalt driveway aprons in the Village right of way (parkway) shall be paved with at least 1-1/2 inches of plant mixed asphalt. All asphalt shall be placed over at least 4 inches of graded and compacted gravel base material. No pea gravel allowed as a base material for driveways. CONCRETE DRIVEWAY CONSTRUCTION REQUIREMENTS: Concrete driveways shall be constructed with at least 5 inches of air entrained concrete fc=3500 psi, with a cement content per ACI318. Concrete driveway aprons in the Village right of way (parkway) shall be constructed with at least 5 inches of air entrained fc=3500 psi, with a cement content per ACI318. All concrete shall be placed over at least 4 inches of graded and compacted gravel base material. No pea gravel allowed as a base material for driveways. Wire mesh is not allowed in the parkway (apron) or public walk area. GARAGE FLOOR CONSTRUCTION REQUIREMENTS: Install thickened concrete edge at overhead door 14 inches down and 20 inches wide. This 14 inch measurement includes the 3 1/2 for the concrete floor replacement. At lease 4 inches of graded compacted gravel base material. Install (2) #5 5/8 inch diameter rebar approximately in bottom of thickened edge at overhead door, approximately 3 inches from bottom along full length. Install vapor barrier under attached garage slabs. Dowel beam into existing foundation @ sides. PAVER DRIVEWAY CONSTRUCTION REQUIREMENTS: Construct brick pavers with a min. 4 inches compacted Grade C.A. 6 stone base and 1-1½ inches sand or as specified by the manufacturer. Edge restraints are to be spiked securely through the compacted base material and the bricks seated into the bedding sand by compaction. Brick pavers are not allowed within the public sidewalk area. DRIVEWAY ZONING REQUIREMENTS: Measurements shall be noted on the submitted Site Plan (see diagrams at right and refer to notes below for example) A Width at lot line, for a minimum distance of 5 feet. Maximum of 25 ft is permitted. B Width at widest point. Maximum 30 ft for a two-car garage or less Maximum 35 ft for a three-car garage or greater Minimum width: 9 ft C Side/Rear yard setback. 2 ft from interior side or interior rear lot line, except when a driveway is shared between 2 adjacent properties. D Length of drive shall be noted on the site plan

DECK CONSTRUCTION REQUIREMENTS: Decks may not cover basement windows, electric or gas meters, or vents. Identify their location on the drawing if in the general vicinity of the deck. All decks that are 30 or higher, require a continuous railing, 36" high. Baluster spacing shall be such that a 4" sphere cannot pass through any opening. All vegetation shall be removed from beneath the deck, and the ground covered with a minimum of four mil polyethylene covered with gravel. Joist hangers or ledger boards are required and where the deck is supported by attachment to an exterior wall, they shall be positively anchored to the primary structure and designed for both vertical and lateral loads. A special use permit is necessary if a proposed deck is in a floodplain and no portion of a deck may be in an easement. Decks shall be installed on a frost protected foundation meeting the approval of the Director of Community Services. See attached check sheet for additional requirements. DECK ZONING REQUIREMENTS: A deck less than sixteen (16) inches above grade shall be situated a minimum distance of two (2) feet from all side and rear lot lines. Decks in a front or corner side yard shall be situated a minimum distance of five (5) feet from the front and corner side lot lines. A deck sixteen inches or more above grade located adjacent to the residence is considered part of the principal structure and must meet the house setback and lot coverage requirements for the zoning district in which it is located. Decks shall not be located in easements. FENCE CONSTRUCTION REQUIREMENTS: "Finished side of fence shall face out. Fences shall be constructed in a manner providing sufficient support and stability to resist wind loads and to maintain its form. Chain link fences shall be constructed of at least eleven and a half (11.5) gauge woven wire - open ends of a wire fence shall be along the ground. FENCE ZONING REQUIREMENTS: General Fencing o Height: Fencing shall not exceed six (6) feet in height. o Type: No barbed wire or electrically charged fences are permitted. o Location and Setbacks Interior side and rear yards Fences are permitted in the rear and interior side yards. Front yards Fences must meet the front yard setback requirements in the zoning district. Side yard abutting a street Fences located in a side yard abutting a public street shall be setback a minimum of 5 feet from the lot line and shall not abut a front yard of an adjacent property. Rear yard abutting a street Fences located in a rear yard abutting a public street shall be setback a minimum of 5 feet from the lot line. Fences located in a rear yard abutting a public street shall include a gate to allow access to the rear street frontage. o Landscape material: shall be installed within the area between a fence and any lot line abutting a street. The landscape material shall include a combination of trees and shrubs with a minimum installed height of 36 inches. Decorative Fencing: (front yard, only) o Height: Fencing shall not exceed three (3) feet in height. o Length: Up to twenty (20) linear feet. o Type: No barbed wire or electrically charged fences are permitted. o Location and Setbacks: Permitted in front yards and corner side yards. Replacement of Existing Fence o Any existing fence, as of April 18, 2005, may be replaced in its current location without having to comply with the applicable setback requirements. Prior to obtaining a building permit the property owner shall provide proof that the fence existed in its current location prior to April 18, 2005.

ELECTRIC SERVICE REVISION CONSTRUCTION REQUIREMENTS: Grounding: Only copper wire shall be used for grounding of electric systems. When grounding for any system or combination of systems and equipment, the copper ground wire shall be run directly from the neutral in the service disconnect or distribution cabinet to the street side of the water service shut-off valve and shall have an approved jumper wire around the water meter with an approved metal I.D. tag denoting electrical ground. In addition, two1/2 inch diameter 8 foot long copper ground rod embedded 7 foot into the ground shall be provided with a copper ground wire run directly to the service disconnect. Service Entrance: The name and telephone number of the electrical contractor performing the work shall be displayed on the service panel. Service entrance conductor's shall be installed in rigid heavy-wall metal conduit with a cabinet containing not less than twenty (20) circuits. In all occupancies, those conductor's which supply all the current consumed by an individual occupancy, apartment, or dwelling unit shall be as follows: o Copper shall be used on the load side of the service. o All occupancies or dwelling units and apartments of any size shall have a one hundred (100) amp. minimum electric service rating. Service panels shall have a minimum of twenty (20) circuits. o The main disconnect switch shall be located in the approximate area where the service enters the building. o A disconnect shall be provided for all occupancies, apartments and dwelling units. o No more than 5 feet from service disconnect to dwelling panel board. Clearances: Conductors shall have a vertical clearance of not less than 8 feet from all points of roofs they pass, where the voltage between conductors does not exceed 300 volts and the roof has a slope of not less that 4/12 a reduction in clearance to 3 feet shall be permitted. Panelboard shall have a ¼ inch clearance to the wall. The above ground service drop shall be no closer that 3' 0'' from a window opening Maintain 30 inch width by 36 inch depth and 78 inch vertical clearance from face of exterior electrical meter FURNACE & A/C CONSTRUCTION REQUIREMENTS: Furnaces must be installed in accordance with manufacturers' installation instructions. Furnaces must be accessible for service, repair and replacement with not less than 30" of working space provided. Fuel shut-off valves must be provided for each unit. Vent connectors must be pitched at least 1/4 inch per foot, be securely supported, and joints fastened with sheet metal screws. Furnaces installed in confined spaces (provide sketch) must be provided with two openings. One opening must be within 12 inches of the top and one within 12 inches of the bottom space. Each opening must be sized 1 square inch per 1000 BTU input rating of all appliances installed within the space. A disconnect switch must be mounted within sight of the unit. Furnace must be properly fused with wire sized in accordance with the manufacturers' installation instructions All electric piping on exterior of building to be in rigid pipe except "seal-tight" will be allowed from electric disconnect to condensing unit. FURNACE & A/C ZONING REQUIREMENTS: A compressor or condensing unit for an air conditioning system must be located in either a rear or side yard unless such yards abut a street wherein said unit shall be located elsewhere. In any required side yard or required rear yard compressor or condenser units and heating pump systems for residential air conditioning systems and/or heating systems shall project not more than three (3) feet into the yard. LAWN SPRINKLER CONSTRUCTION REQUIREMENTS: Indicate polyethylene plastic pipe underground Type L copper shall be used for above ground water piping complete with lead free solder and installed by a licensed plumbing contractor. An R.P.Z valve shall be used. Indicate model # of R.P.Z. valve. All inside plumbing work, including the R.P.Z. valve shall be installed by a licensed plumber. R.P.Z. valve shall be certified prior to inspection. LAWN SPRINKLER LOCATION: A residential lawn sprinkler system may be installed anywhere inside the property lines of a given parcel. However, a residential lawn sprinkler system shall not be installed in an existing utility easement, without the approval of all utility companies. It should be noted that if permission is granted by the utility companies and a sprinkler system is installed over an existing easement, the property owner is responsible for replacing the lawn sprinkler system if damaged by the utility companies needing access. No irrigation lines or sprinkler heads are permitted in the right-of way without a signed hold harmless letter.

PAVER PATIO/SIDEWALK CONSTRUCTION REQUIREMENTS: Construct brick pavers with a min. 4 inches compacted Grade C.A. 6 stone base and 1-1½ inches sand or as specified by the manufacturer. Edge restraints are to be spiked securely through the compacted base material and the bricks seated into the bedding sand by compaction. Pitch sidewalk and patio away from building. Surface water drainage may not be directed onto adjacent properties. If a walk or patio includes steps or a stoop with more than 2 contiguous steps, a full permit application is required. Risers may not be more than 7 3/4 inches in height and treads not less than 11 inches in depth or 10 inches with nosing. PAVER PATIO/SIDEWALK ZONING REQUIREMENTS: A brick patio and/or sidewalk if less than 16 inches in height above grade should be situated a minimum of two (2) feet from all side and rear lot lines. A brick patio and/or sidewalk cannot be constructed on utility easements without the written permission of all utility companies. It should be noted that if permission is granted by the utility companies and a patio and/or sidewalk is constructed over an existing easement, the property owner is responsible for replacing the patio and/or sidewalk if damaged by the utility companies needing access. CONCRETE PATIO/SIDEWALK CONSTRUCTION REQUIREMENTS: Public concrete walks shall be constructed with at least 5 inches of air entrained concrete fc=3500 psi, with a cement content per ACI318. Private walks and patios shall be constructed with at least 4 inches of air entrained concrete fc=3500 psi, with a cement content per ACI318. All concrete shall be placed over at least 4 inches of graded and compacted gravel base material. No pea gravel allowed as a base material. Pitch sidewalk and patio away from building. Surface water drainage may not be directed onto adjacent properties. If a walk or patio includes steps or a stoop with more than 2 contiguous steps, a full permit application is required. Risers may not be more than 7 ¾ inches in height and treads not less than 11 inches in depth or 10 inches with a nosing. CONCRETE PATIO/SIDEWALK ZONING REQUIREMENTS: A concrete patio and/or sidewalk if less than 16 inches in height above grade should be situated a minimum of two (2) feet from all side and rear lot lines. A concrete patio and/or sidewalk cannot be constructed on utility easements without the written permission of all utility companies. It should be noted that if permission is granted by the utility companies and a patio and/or sidewalk is constructed over an existing easement, the property owner is responsible for replacing the patio and/or sidewalk if damaged by utility companies gaining access. SEWER REPAIR CONSTRUCTION REQUIREMENTS: Schedule 40 or S.D.R. #26 pipe is to be used. Install 6" PVC schedule 40 with "T" for outside clean out if none exists in sewer service rod-out station. Outside clean out is mandatory for outside sewer repair. The sewer repair or replacement section shall be installed in a gravel bed Install non-shear mission couplings on both ends Remove all old pipe out of ditch before backfill Rod out sewer to make sure it is working before backfill Remove debris from site caused by sewer repair - pop cans, rags, old pipe, etc. Any municipal property (parkway, street, curbs, sidewalk, etc) damaged during construction shall be restored and is subject to a one (1) year maintenance period. SHED CONSTRUCTION REQUIREMENTS: When storage sheds are built on other than concrete floors, the perimeter of the shed shall be constructed in a manner to discourage rodents from building nests under the structure. Regardless of the weight or size of the shed, it must be anchored to the ground by using hurricane anchors, posts, or a method approved by the Village of Palatine. If the shed is built on a wooden floor, the floor shall be constructed of pressure treated lumber or of a decay resistant species of lumber such as cedar. If a concrete floor is installed for the shed, the requirements shall be 4 inches of concrete over 4 inches of compacted fill.

SHED ZONING REQUIREMENTS: A maximum height of fifteen (15) feet as measured from the ground level to the mean height between the eave and ridge of a roof. A detached shed cannot be constructed on utility easements without the written permission of all utility companies. It should be noted that if permission is granted by the utility companies and a patio and/or sidewalk is constructed over an existing easement, the property owner is responsible for replacing the patio and/or sidewalk if damaged by utility companies gaining access. All sheds must be located in either the rear or side yards and be situated a minimum of ten (10) feet from the principal structure. In addition, sheds must be located a minimum of five (5) feet from all side and rear lot lines, not in the easements. If a rear lot line of a lot abuts the side lot line of a front yard of an adjacent lot, a shed must be setback a minimum of twenty (20) feet from the rear lot line. A shed cannot encroach upon the side yard of a corner lot which is adjacent to the street. In addition, a shed cannot encroach upon the corner side yard setback in a rear yard of a corner lot adjacent to the street. No portion of a shed shall overhang or be located in an easement. Ground floor area Rear yards: The ground floor area of all accessory structures located in a rear yard shall nor exceed the lesser of: i. Twenty (20) percent of the area of such rear yard or; ii. Seven hundred (700) square feet iii. Fifty percent (50) of the floor area of the principal structure Side yards: Maximum size is 150 square feet WATER HEATER CONSTRUCTION REQUIREMENTS: The water heater shall be installed in accordance with manufacturers specifications and the Illinois State Plumbing Code. A full port shut-off valve must be located on the cold water side. Water connections to the water heater must be made with dialectic unions if dissimilar metals are used. All soldering must be done with lead free solder. All copper pipe shall be type L rigid pipe, no flexible connectors. A relief valve and its discharge piping shall be of full size and extend to within 6 inches above the floor and discharge to a suitable drain. Install heat trap. Water heaters installed in a closet or other confined space must be provided with two ventilation openings. One opening must be within 12 inches of the top and one within 12 inches of the bottom space. Each opening must be sized 100 square inches. A new water heater replacement should be located in the same general area as the older water heater and if installed on a platform, shall again be installed on a platform of the same elevation as the original heater. A gas fired water heater in a garage must be raised 18 inches above the floor. If an electric water heater is installed, it must conform to the appropriate electrical code sections. Proper clearances as specified by the manufacturer must be provided between the water heater and combustible material. ABOVE GROUND POOL CONSTRUCTION REQUIREMENTS: Pools and associated elements shall be constructed in accordance with appendix G of the 2003 International Residential Code and the electrical requirements of the 2005 National Electrical Code. See attached reference sheets. Hose bibs used to fill the pool must be equipped with a vacuum breaker. ABOVE GROUND POOL ZONING REQUIREMENTS: An above ground swimming pool and any accessory equipment can be located in either a rear or side yard, however, above ground swimming pools are not permitted in front yards or side yards abutting a street. An above ground swimming pool and any accessory equipment must be situated a minimum of ten (10) feet from the principal structure and shall not be located closer than five (5) feet from any rear or side lot lines. Pools shall not be located on an easement. Ground floor area: o Rear yards: The ground floor area of all accessory structures located in a rear yard shall nor exceed the lesser of: Twenty (20) percent of the area of such rear yard or; Seven hundred (700) square feet Fifty percent (50) of the floor area of the principal structure