CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS DOCUMENT 00085B ADDENDUM ADDENDUM NO. 1

Similar documents
ITEM 555 CHAIN LINK FENCING

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

TITLE: CAMP JOHNSON OVERPASS / HWY 17 BYPASS SECURITY FENCE UPGRADES

SECTION CHAIN LINK FENCES

SECTION CHAIN LINK FENCES AND GATES (PARK)

SECTION CHAIN LINK FENCING

SECTION 1208 CHAIN LINK FENCING DESCRIPTION

Colorado River Aqueduct Pumping Plants 230 kv Disconnect Switches Replacement

SECTION 2831 ITEM F-162 CHAIN-LINK FENCES

CW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS

SECTION CHAIN LINK FENCES AND GATES

CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

CHAIN LINK FENCES AND GATES

CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE

SECTION CHAIN LINK FENCES AND GATES

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN LINK FENCING

A NEW PRE-K BUILDING FOR BIG SPRING LAKE KINDERGARTEN SCHOOL FOR THE ALBERTVILLE CITY BOARD OF EDUCATION ALBERTVILLE, ALABAMA

SECTION CHAIN LINK FENCES AND GATES

ANTI RAM SECURITY CHAIN LINK FENCE - 4, MPH SECTION

Special Provision No. 541S01 October OPSS 541, Construction Specifications for Chain Link Fence, is deleted and replaced with the following:

A. Product Data shall be provided for each type of product indicated.

SECTION CHAIN LINK FENCES AND GATES

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

Bear Exhibit Fence Upgrades. The following modifications are hereby made part of the contract documents:

SECTION 410 FENCES All materials shall be new and without flaws or defects of any type GENERAL

SECTION 1043 FENCE MATERIAL

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION CHAIN LINK FENCING

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

MO: Tl RSA: 1406B

A. ASTM A121 Specification for Metallic-Coated Carbon Steel Barbed Wire. B. ASTM A392 Specification for Zinc-Coated Steel Chain-Link Fence Fabric

Advisory Circular PAGECONTROLCHART. Remove Pages Dated II Inscr t Pages Dated l/2/ thru 258-l 7/6/ l/2/90

Invitation to Bid MHM

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

AMERICAN SAMOA POWER AUTHORITY Materials Management Office INVITATION FOR BIDS ( IFB ) EAST SIDE WELLS-BOOSTERS SECURITY FENCE REPLACEMENT

MATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION FENCING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

1. Fence and gate posts, rails, and fittings. 2. Chain-link fabric, reinforcements, and attachments.

A. Coordinate chain link fence & gate work with work before and after. See especially: 1. Bollards on worksite that are more than 10 ft from fence.

1. Include plans, elevations, sections, details, and attachments to other work.

SECTION ORNAMENTAL WELDED STEEL FENCING

Automated Cantilevered Aluminum Sliding Gate

SECTION NON-STRUCTURAL METAL FRAMING

PROJECT MANUAL FENCING FOR PEPSI WATER TANK & ROCKTOWN WATER TANK FOR TOWN OF KINGSTREE KINGSTREE, SOUTH CAROLINA

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

SECTION ORNAMENTAL ALUMINUM FENCING

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2007

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

TRANSPORT LINK CHAIN LINK CANTILEVER GATES

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

TOWN OF OSOYOOS PERIMETER FENCING OSOYOOS LANDFILL

SECTION ALTERNATING TREAD STEEL STAIRS

Amendment to OPSS 772 (Nov 2012) Construction Specification for Chain-Link Fence

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LOW-TENSION CABLE BARRIER. OPR:CT 1 of 5 APPR:JAR:DBP: FHWA:APPR:

LRGVDC Rio Transit Center Renovation & Expansion

PROPOSAL FOR WROUGHT IRON PERIMETER FENCE WITH GATE TO CITY OF POMONA

CONSTRUCTION SPECIFICATION FOR SITE RESTORATION FOR UNDERGROUND UTILITIES

UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

ITCC provides products to comply entirely with international standards specifications; applicable standards are ASTM, BSI, & SSD.

REQUEST FOR BIDS Public Works Contract SPECIFICATIONS FOR FENCE REPAIRS AND REPLACEMENT

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SPECIFICATION FOR PERMANENT BEAM GRANDSTAND WITH INTERLOCK WELDED DECK SYSTEM

ITEM 442 METALS FOR STRUCTURES

TRANSPORT II " 10.5" MOUNTING POSTS FENCE LINE POST. Classic gate shown GATE OPENING CANTILEVER GATE SAFETY WARNING

City of New Haven. 101 FRONT STREET PO BOX 236 NEW HAVEN, MO Phone * * Fax

SECTION DECORATIVE METAL RAILINGS

SECTION PRE-ENGINEERED METAL BUILDING

SECTION ALTERNATING TREAD STEEL STAIRS

A. The work under this section consists of furnishing and installing gauge steel framing and bracing as indicated on the drawings and as specified.

SECTION METAL ATHLETIC LOCKERS

PLUMAS COUNTY FLOOD CONTROL & CONSERVATION DISTRICT 1834 East Main Street, Quincy, CA Telephone: (530)

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

CONSTRUCTION SPECIFICATION FOR EXPANDED METAL ANTI-GLARE SCREEN

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

SECTION ACCORDION FOLDING PARTITIONS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION Permanent Grandstands PART 1 GENERAL 1.1 RELATED DOCUMENTS

Item 442 Metal for Structures

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING

ENGINEERING, CONSTRUCTION AND MATERIAL STANDARD FOR FENCING AND GATES ORIGINAL EDITION MAY. 1997

SECTION 2 DIVISION 05 METALS

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

SECTION MISCELLANEOUS METALS

FOUR STRAND BARBED WIRE FENCE SPECIFICATIONS

SECTION ROOF ACCESSORIES

METALS Commissioning of Metals Structural Steel Framing Steel Studs... 2

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Transcription:

ADDENDUM Date of Addendum: December 30 th, 2015 PROJECT NAME: Fencing for Sportspark PROJECT NO: GO1507 BID DATE: Tuesday, January 5 th, 2016 FROM: City of Friendswood Department of Public Works 1306 Deepwood Drive Friendswood, TX 77546 DOCUMENT 00085B ADDENDUM ADDENDUM NO. 1 TO: Prospective Bidders This Addendum forms a part of the Bidding Documents and will be incorporated into the Contract documents, as applicable. Insofar as the original Project Manual and Drawings may conflict, this Addendum governs. This Addendum uses the change page method: remove and replace or add pages, or Drawing sheets, as directed in the change instructions below. Change bars ( ) are provided in the outside margins of pages from the Project Manual to indicate where changes have been made; no change bars are provided in added Sections. Reissued Drawing Sheets show the Addendum number below the title block and changes in the Drawing are noted by a revision mark and enclosed in a revision cloud. SPECIFICATIONS: Section 02935 Chain Link Fence. Add section including pages 02935-1 through 02935-9 (Attached). CLARIFICATIONS: Q: Will the trees located near fields 5 & 6 be trimmed or relocated by the owner? A: The trees will be trimmed by the owner if needed at the mutual determination the trees are an impedance to the contractor. 00085B-1

ADDENDUM Q: What is the Engineer s estimate for the project? A: The Engineer s estimate is $110,000 for this project. Q: What is the pole spacing loading and wind speed? A: The pole spacing is a maximum of ten (10) feet and needs to be rated for 110 mph. Q: Can we have a fillable Bond Document? A: Yes, there will be one placed on the City s website at: www.friendswood.com/publications. END OF ADDENDUM NO.: 1 END OF DOCUMENT 00085B-2

SECTION 02935 PART I: GENERAL 1.1 GENERAL REQUIREMENTS A. Furnishing and installation of chain link fencing, galvanized steel posts, and gates plus all accessories incidentals and specials necessary for the proper erection and installation of the fence and gates. B. The Contractor shall construct chain link fencing including posts, and gates as shown on the Drawings and in accordance with this Specification. 1.2 MEASUREMENT AND PAYMENT A. Unit Prices: 1. Payment for Chain Link Fence shall be on a per linear foot basis to include all necessary hardware, concrete, materials and labor. 2. No separate payment shall be made for each gate. Gates shall be paid under Chain Link Fence as part of the linear footage. 3. Refer to Section 01270 Measurement and Payment for unit price procedures. B. Stipulated Price (Lump Sum): 1.3 REFERENCES 1. If Contract is Stipulated Price Contract, payment for work in this Section is included in Total Stipulated Price. A. ASTM American Society for Testing and Materials. 1. ASTM A53 Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless. 2. ASTM A90 Standard Test Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings. 02935-1

3. ASTM A121 Standard Specification for Metallic-Coated Carbon Steel Barbed Wire. 4. ASTM A123 Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products. 5. ASTM A153 Standard Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware. 6. ASTM A392 Standard Specification for Zinc-Coated Steel Chain-Link Fence Fabric. B. CTFS City of Friendswood Specifications. 1.4 SUBMITTALS 1. Section 01270 Measurement and Payment. 2. Section 01330 Submittal Procedures. 3. Section 01580 Waste Material Disposal. 4. Section 03300 Structural Concrete. A. Conform to requirements of Section 01330 Submittal Procedures. B. Submit proposed design mix and test data for each type and strength of concrete. C. Submit manufacturer's data and details of following items for approval: 1. Chain Link Fabric Mesh. 2. Galvanized Posts. 3. Materials to be used for installation. 4. Latch and hinge hardware. 5. Installation instructions for forms. 02935-2

PART II: PRODUCTS 2.1 A. Wire Fabric for fencing shall be nine gauge (9 Ga) steel with a minimum tensile strength of eighty thousand pounds per square inch (80,000 psi). Mesh size shall be two inches (2 In) between parallel wires. Top salvages knuckled for sixty inch (60 In) or less in height. Top and bottom salvages twisted and barbed for fabric over sixty inches (60 In) in height. Fabric shall be furnished in one-piece. B. Barbed Wire for mounting on security arms to be twelve and one-half gauge (12 1/2 Ga) with four-point (4 pt) barbs spaced at five inches (5 In) apart. Three (3) strands of barbed wire shall be required. C. Fabric Ties shall be eleven gauge (11 Ga) steel to fasten fabric to top rail at eighteen inch (18 In) intervals. Ties shall be furnished to fasten the fabric to the bottom tension wire at eighteen inch (18 In) intervals. Ties shall be furnished to attach fabric to line posts at fifteen inch (15 In) intervals. D. Bottom Tension Wire shall be seven gauge (7 Ga) coil wire. 2.2 RAILS AND S A. Top Rail shall be one and sixty-six hundredths inch (1.66 In) outside diameter (OD) steel pipe weighing two and twenty-seven hundredths pounds per foot (2.27 lb/ft). Top rail shall be furnished in random lengths not less than eighteen feet (18 Ft) per section and shall be joined with outside sleeve, steel couplings not less than six inches (6 In) long and having a wall thickness not less than seven hundredths of an inch (0.7 In) Couplings shall be designed to allow for expansion and movement of the top rail. B. Posts shall be furnished in sufficient quantity to provide a maximum spacing of ten feet (10 Ft). Minimum size and weights are as specified in TABLE 4.1 LINER REQUIREMENTS, TABLE 4.2 CORNER, PULL AND END REQUIREMENTS, and TABLE 4.3 GATE S in this Section. C. Post Brace Assembly shall be manufacturers standard adjustable brace at end and gate posts, at both sides of corner and pull posts, with horizontal brace located at mid-height of fabric. Brace to be same material as top rail and trussed to line posts with three-eighths inch (3/8 In) diameter rod with adjustable turnbuckles. 02935-3

D. Post Caps for pipe shall be designed to exclude moisture. Where barbed wire is specified, extension arms shall be integral with post caps. Where top rail is specified, post caps shall have an opening for the top rail. All post caps shall have a two inch (2 In) skirt for rigidity. E. Tension bars shall be not less than three-sixteenths of an inch (3/16 In) by three-quarters of an inch (3/4 In) flat steel and not more than two inches (2 In) shorter than the fabric height. One (1) tension bar shall be provided for each gate and end post. Two (2) tension bars shall be provided for each corner and pull post. Tension bars shall be attached to terminal posts with one inch (1 In) twelve gauge (12 Ga) flat steel bands, with carriage bolts at intervals not exceeding fifteen inches (15 In). F. Barbed Wire Support Arms shall be metal and finish to match fence framework, with provision for anchoring to posts and attaching three (3) rows of barbed wire with each arm. Supporting arms may either be attached to posts or integral with post top weather cap and shall be capable of withstanding two hundred fifty pounds (250 Lb) downward pull at outermost end. Arms shall be at a forty-five degree (45 ) angle from vertical. 2.3 GATES A. Fabricate perimeter frames of gates from metal and finish to match fence framework. Assemble gate frames by welding or with special fittings and rivets for rigid connections, providing security against removal or breakage connections. Provide horizontal and vertical members to ensure proper gate operation and attachment of fabric, hardware, and accessories. Space frame members a maximum of eight feet (8 Ft) apart unless otherwise indicated. Provide same fabric as for fence, unless otherwise indicated. Install fabric with tension bars at vertical edges and at top and bottom edges. Attach tension bars to gate frame not more than fifteen inches (15 In) on center (OC). Install one (1) diagonal cross-bracing consisting of a minimum threeeighths inch (3/8 In) adjustable length truss rods with turn-buckles on gates to ensure frame rigidity without sag or twist. Where barbed wire is indicated above gates extend end members of gate frames one foot (1 Ft) above top member and prepare to receive three (3) strands of wire. Provide necessary clips for securing wire to extensions. B. Swing gates shall be fabricated with frames a minimum of one and seven-eights inch (1 7/8 In) outside diameter (OD) pipe weighing two 02935-4

and seventy-two hundredths pounds per foot (2.72 Lb/Ft). The top of all gate frames shall align with the fencing top rail. Vehicular gates shall be four inches (4 In) greater in overall height than the adjacent fencing so as to extend to within two inches (2 In) of pavement between curb, if curbs are designated are designated on the Drawings. 1. Corner and tee fittings of malleable iron or pressed steel having means of attaching diagonal members. Hinges of malleable iron providing for full one hundred eighty degree (180 ) swing with bottom hinges to be ball and socket type. 2. Diagonal braces consisting of a minimum one-half inch (1/2 In) truss rods with turn-buckles, two (2) for each gate frame. Vertical gates shall have vertical one and seven-eighths inch (1 7/8 In) outside diameter (OD) pipe brace at the center of each gate leaf. C. Provide gate hardware and accessories for each gate galvanized in accordance with ASTM A153 and as specified below: 1. Hinges: Size and material to suit gate size, non-liftoff type, offset to permit one hundred eighty degree (180 ) gate opening. Provide three (3) hinges for each leaf over six foot (6 Ft) nominal height. 2. Latch: Forked type or plunger-bar type to permit operation from either side of gate with padlock eye as integral part of latch. 3. Provide keeper for vehicle gates which automatically engages gate leaf and holds it in open position until manually released. Keeper to be anchored at least twelve inches (12 In) into a twelve inch by twenty-four inch (12 In x 24 In) concrete footing. 4. Double gates shall be provided with gate stops consisting of mushroom type flush plate with anchors, set in concrete, and designed to engage center drop rod or plunger bar. Include locking device and padlock eyes as integral part of latch permitting both gate leaves to be locked with single padlock. D. Roller Gates shall be the responsibility of the Contractor to design using same fabric as for fence. Drawings shall indicate the size of opening for single or double gate application. Design to provide for free flowing opening and closing. Additional rollers or support bearing wheel should be incorporated to minimize binding where necessary. 02935-5

2.4 GALVANIZING A. All material used in chain link fencing shall be hot-dip zinc coated as specified by the following: 1. All posts and pipe shall be one and eight-tenth ounces per square foot (1.8 Oz/SF) in accordance with ASTM A53. 2. All H-Beam Sections shall be two ounces per square foot (2.0 Oz/SF) in accordance with ASTM A123. 3. Fence Fabric shall be one and two-tenths ounces per square foot (1.2 Oz/SF) in accordance with ASTM A392, Class I. 4. Tension and Barbed wire shall be eight-tenths ounce per square foot (0.8 Oz/SF) in accordance with ASTM A121, Class III. 5. Post Caps, Tension Bars and Miscellaneous fittings shall be in accordance with ASTM A153. 6. The weight of zinc coating for all items shall be determined in accordance with ASTM A90. PART III: EXECUTION 3.1 INSTALLATION A. The fence shall be installed by skilled and experienced fence erectors, and on lines and grades indicated on the Drawings. 3.2 CONSTRUCTION A. The Contractor shall perform all clearing of brush and debris, which may be necessary for the installation of the fencing. B. The fencing panels between corner and terminal posts shall generally follow the finished ground elevations. The Contractor shall grade off minor irregularities in the path of the fencing as necessary to limit the variation of grade under bottom edge of fence fabric to a distance of not more than six inches (6 In) and not less than two inches (2 In) from the ground at any point along the fencing. 02935-6

C. Post Spacing: D. Holes 1. Line Posts shall have a maximum spacing of no more than ten feet (10 Ft). 2. Pull Posts shall not be located more than five hundred feet (500 Ft) and shall be installed at each change in direction exceeding twenty degrees (20 ), both vertically and horizontally. 3. Runs of fencing over five hundred feet (500 Ft) but less than one thousand feet (1,000 Ft) shall have a pull post in the center of the run. 1. Holes for concrete footings for all posts shall be drilled to the dimension as specified in TABLE 4.4 S FOR LINE, TABLE 4.5 S FOR END S, and TABLE 4.6 S FOR GATE S. 2. Concrete footings shall be Class A Concrete, NO EXCEPTIONS. Concrete shall be in accordance with Section 03300 Structural Concrete. All concrete footings shall be cast up to finished grade and crowned one inch (1 In) to shed water. Excess concrete and other material shall be removed and disposed of in accordance with Section 01580 Waste Material Disposal. E. The fence fabric shall be erected by securing one (1) end and applying sufficient tension to the other to remove all slack before making attachments. The fabric shall be cut and each span shall be attached independently at all corner posts and pull posts. F. Fastening to end, pull, corner and gate posts shall accomplished with tension bars which shall be secured to the post with tension bar bands at intervals not to exceed fifteen inches (15 In). G. Fence fabric shall generally follow the finished contour of the site with the bottom edge of the fabric located two inches (2 In) above the grade. H. Erect fencing to generally follow ground surface and adjust irregularities in grade. Where depressions or swales are crossed by the fencing, provide galvanized pipe and ire fabric laced to main fabric to prevent entrance of small animals but permit natural drainage flow. I. Join top rails with suitable sleeve-type couplings, making rigid 02935-7

connections with provisions for expansion and contraction. Pass rail through base line post barbed wire extension arm and fasten securely to terminal post. J. Brace all terminal posts with brace member securely fastened to terminal and first line post. Tie terminal post near ground line to line post at brace member with steel tension rod complete with turn-buckle. PART IV: TABLES TABLE 4.1 LINE REQUIREMENTS OUTSIDE DIA. PIPE SECTION (LB/FT) H-BEAM SECTION (LB/FT) LENGTH 0 to 4 1.90 2.27 2.70 24 4 to 8 2.375 3.65 4.10 24 8 to 12 2.875 5.79 5.79 24 TABLE 4.2 CORNER, PULL AND END REQUIREMENTS OUTSIDE DIA. PIPE SECTION (LB/FT) LENGTH 0 to 4 2.75 3.65 30 4 to 8 2.875 5.79 36 8 to 12 3.50 9.10 36 TABLE 4.3 GATE REQUIREMENTS OUTSIDE DIA. PIPE SECTION (LB/FT) LENGTH 0 to 4 2.875 5.79 36 4 to 8 4.00 9.11 36 8 to 12 6.625 18.79 42 02935-8

TABLE 4.4 S FOR LINE S DIA. DEPTH 0 to 4 9 30 24 4 to 8 9 30 24 8 to 12 9 30 24 TABLE 4.5 S FOR END S DIA. DEPTH 0 to 4 12 36 30 4 to 8 12 42 36 8 to 12 12 42 36 TABLE 4.6 S FOR GATE S DIA. DEPTH 0 to 4 12 42 36 4 to 8 18 42 36 8 to 12 18 48 42 END OF SECTION 02935-9