typical section 1:50 Important:

Similar documents
FACE CFP - HORIZONTAL PANELS - OPTION 'B'

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

Timber Separating Walls 3.3.3

FIRE RATING MATERIAL FIXING NOTES

NU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)

MR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA

The better way to build TM. Installation Manual NAILBASE PANELS

BENCHMARK Evolution Axis

rondo accessories CONTENTS:

ELEVATION FOR DETAIL REFERENCE ONLY

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

Typical detail: New roof with breathable underlay

Pebbletex Wall System Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Technical & Installation Manual

SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals

GAF EnergyGuard Polyiso Wall Sheathing

WeatherSmart Air Barrier Installation Guide

Bituminous Roofing Underlay & Valley Guard

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

STOPOREN FACADE SYSTEM PARAPET/METAL FLASHING DETAIL

LEEDS : LEEDS UNIVERSITY

Installation Guide. HardieBreak Thermal Strip COMPONENTS

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

ELEVATION FOR DETAIL REFERENCE ONLY

Commercial Flashing Details

Concrete Soffit Direct Fix

Applies to lots: 6, 7, 10, 17, 18, 25, 26 Applies to lots: 1, 2, 3, 4, 8, 9, 12, 13, 14, 15, 16, 20, 21, 22, 23, 27, 28, 29, 30, 31

Note:

Introduction. Applications. Everest Facade Advantages

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

Ameriplate. Rain Screen Wall System

Arcwall. Rain Screen Wall System

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Bituminous Building Paper

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

TYPICAL DETAILS MANUAL

SEPARATING WALLS CLASS 1A

excom (Expressed Panel Facade System) Primary top hat 160 x 35 x 1.0mm mm.

ELEVATION FOR DETAIL REFERENCE ONLY

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

COMPANY NAME: Lump Sum. Lump Sum. Lintel 33. brick 500. L. ft. 200

ELEVATION FOR DETAIL REFERENCE ONLY

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

SURESILL WATER MANAGEMENT GUIDE

Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing

130mm CROATIA BOARD 180mm V-GROOVE

COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

Specifications for Insulation Board wall and ceiling applications

Part E robustdetails. robustdetails. January 2018 Update Pack

Design Guide. HardieSmart Boundary Wall System (Class 1 & 10a) SYSTEMS FRL 60/60/60 FROM THE OUTSIDE. Rw R

TECHNICAL DOCUMENT: SYSTEM INSTALLATION & CONSTRUCTION DETAILS

Design Manual Facade, riveted Panel fixed to T-Sections

Residential Wall Panel Installation

A Handbook of thermal bridging details incorporating aircrete blocks

Real Brick Cladding. Iso Klink Pur. Brick Panel System Catalogue

Siding and Soffit Installation Guidelines

Aqua Coast Engineering

The Passive Fire Protection Handbook

100 mm. 100 mm. 125 mm. 125 mm. 150 mm. 150 mm C003 C001 C269 C208 C055 C002. Tee Gee. Feather Edge. Shiplap. Open V. Open V.

A. SYSTEM DETAILS A.1 Product Range

Installation Guide. ExoTec TM RAW (Pre-Finished) Facade Panel And Fixing System COMMERCIAL & RESIDENTIAL

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50

AA Series 150mm Frame Doors (3 & 6 Panel Stacker Doors Illustrated)

A Handbook of thermal bridging details incorporating aircrete blocks

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Wet Areas Using Plasterboard

Illawarra Flame G-000 UNIVERSITY OF WOLLONGONG SOLAR DECATHLON 2013 COVER. Team Name: Address: Contact:

SECTION GYPSUM BOARD ASSEMBLIES

SPECIFICATION: CLASSIC PROGRESSIVE MOVABLE WALL SYSTEM DEMOUNTABLE STEEL STUD AND GYPSUM BOARD PARTITIONS

Ameriplate. Rain Screen Wall System

DURAGRID TM FACADE SYSTEMS

SECTION NON-STRUCTURAL METAL FRAMING

Primary Concerns and Defects

Light-Metal Roof Edge, Raised

Siding and Soffit Installation Guidelines

AS Interpretation of External Waterproofing as it applies to Melbourne, Class 1 buildings

PARKSIDE QUARRIES Ltd

AA Series 90mm Frame Windows (Operated Casement Window Illustrated)

Detail Booklet StoTherm ci XPS

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

CEMINTEL FIBRE CEMENT SYSTEMs RESIDENTIAL EXPRESSWALL. fc936 oct external cladding systems

Transcription:

00 Typical ventilated facade installation mounted with top hat channels onto external walls, awning soffit and fascia. 00 Wall panels are shown in varying heights, having open joints for ventilation of the cavity which is open along the full extent of bottom and top edges. 00 00 Important: Parklex panels incorporate a balancing timber veneer to the back of the panel in order to balance the differential in expension rates between core and facing materials, thereby eliminating buckling of panels under changes in atmospheric conditions. However, buckling of panels may still occur if Parklex is installed incorrectly with differing exposure between front and rear faces of panels. Therefore, Parklex must be installed with a fully ventilated cavity as depicted in these drawings or an equivalent system, such that temperature, humidty and air movement are equalised between both faces of panels. A ventilated cavity also aids in the control of moisture and heat through the external building envelope. 00 00 typical section :0

00 00 00 00 00 00 00 00 00. mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape.. 0mm wide open joints between panels.. Line of floors and ceiling behind.. Bottom edge of wall panels (behind awning fascia).. Indicative window. typical elevation :0 - conceal fixed with M tape dwg no. parklex-00/

00 00 00 00 00 00 00 00 00. mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape...... 0mm wide x mm deep x.mm bmt top hat channels fixed vertically at maximum 0mm centres. 0-0mm long x mm deep spacer top masonry wall, spaced 00mm at ends and maximum 00mm intermediate centres. 0mm wide joint (not filled or backed). Line of floors and ceiling behind Bottom edge of wall panels (behind awning fascia). Indicative window. typical elevation :0 showing support framings - conceal fixed with M tape dwg no. parklex-00/

. mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape... 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres. 00-00mm long x mm deep spacer top masonry wall, at 00mm maximum centres.. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and perimeter with continuous bead of Sikaflex Pro... 0mm wide joint (not filled or backed).. Indicative metal sheet parapet cladding.. Indicative flashing.. 0. Indicative wall/ parapet framing. Indicative box gutter.. Indicative roofing.. Indicative structural steel.. Indicative substrate walls.. Indicative internal ceiling and wall linings. 0 typical section detail : parapet wall - conceal fixed with M tape dwg no. parklex-00/

0 0 typical jamb detail : typical head detail :. mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape.. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres. 0. 00-00mm long x mm deep spacer top masonry wall, at 00mm maximum centres.. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and perimeter with continuous bead of Sikaflex Pro.... 0mm wide joint (not filled or backed). Flashing.. Caulking.. Indicative wall framing. 0. Indicative window.. Indicative window sill... Indicative sill board. Indicative substrate walls.. Indicative internal ceiling and wall linings. typical sill detail : - conceal fixed with M tape dwg no. parklex-00/

..... mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres. 00-00mm long x mm deep spacer top masonry wall, at 00mm maximum centres. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and perimeter with continuous bead Sikaflex Pro... 0mm wide joint (not filled or backed). Flashing.. Caulking.. Indicative wall framing. 0.. Indicative concrete edge beam. Indicative wall substrate.. Indicative internal ceiling and wall linings. 0 - conceal fixed with M tape typical section detail : dwg no. parklex-00/

... mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres. 00-00mm long x mm deep spacer top hat or block fixed through sarking and backing sheet to plate, nogging or girt (provide masonry wall, spaced at 00mm maximum centres... Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and and perimeter with continuous bead Sikaflex Pro... 0mm wide joint (not filled or backed). Flashing.. Indicative wall framing.. Indicative substrate wall. 0. Indicative concrete edge beam... Indicative internal ceiling and wall linings. Indicative box gutter.. Indicative structural steel.. Indicative roofing.. Indicative concealed grid ceiling suspension system. typical section detail : awning gutter - conceal fixed with M tape dwg no. parklex-00/

. mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape.. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres.. 00-00mm long x mm deep spacer top hat or block fixed through sarking and backing sheet to plate, nogging or girt (provide masonry wall, spaced at 00mm maximum centres.. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and and perimeter with continuous bead Sikaflex Pro... 0mm wide joint (not filled or backed).. Flashing.. Indicative roofing.. Indicative structural steel. 0. Indicative fascia framing.. Indicative concealed grid ceiling suspension system.. Indicative roof purlin. 0 typical section detail : awning fascia - conceal fixed with M tape dwg no. parklex-00/

typical plan detail :.. mm thick panel fixed to top hat with mm wide x.mm thick M VHB continuous adhesive tape. 0mm wide x mm deep x.mm bmt top hat channels fixed vertically, spaced at maximum 0mm centres.. 00-00mm long x mm deep spacer top masonry wall, at 00mm maximum centres.. Impermeable non-reflective sarking lapped 0mm at joints, sealed at joints and perimeter with continuous bead of Sikaflex Pro. typical plan detail :.. Hardi-flex fibre cement sheet (to framed up walls). 0mm wide joint (not filled or backed).. Indicative wall framing/ substrate. typical plan detail : - conceal fixed with M tape dwg no. parklex-00/