Cost Reduction Potential of Polymeric Collectors

Similar documents
Task 54 Webinar. Price Reduction of Solar Thermal Systems

Cost Reduction by temperature limitation

Reference System, Germany Solar domestic hot water system, single-family house

Reference System, Austria Solar combisystem system, single-family house

Polymeric Materials for Solar Thermal Applications Subtask B: Collectors and Components

The next steps towards allpolymeric solar collectors

INFO Sheet A06. Reference System, Austria Solar Domestic Hot Water system, multi-family house. Introduction. Hydraulic Scheme of the System

Reference System, Germany Solar combi system for DHW* preparation and space heating

Reference System, Germany Solar Domestic Hot Water System for Single-Family House

Reference System, Austria Solar domestic hot water system for single- family house

Improvements Developed during the IEA SHC Task 54

Reference System, Austria Solar domestic hot water preparation for multi- family house

Reference System, Austria Solar Domestic Hot Water System for Single-Family House

Reference System, Austria Solar Domestic Hot Water System for Single-Family House

Reference System, Austria Solar Domestic Hot Water System for Multi-Family House

Reference System, Switzerland Solar Domestic Hot Water system, multi-family house

Reference System, France Drain-back multi-family solar domestic hot water system INFO Sheet A 16

Effects of Technological Measures on Costs

Solar Energy Technologies

Project PolarSol koti 41\193\- Map section

Solar Thermal Systems- A reliable technology for Green Buildings

Advanced Storage Concepts for Solar Combisystems

Performance analysis of a PV driven heat pump system during a heating season in high latitude countries

Energy efficiency of buildings from Europe to Slovakia

Solar thermal heating systems in European Union

Solar Combisystem European Overview of installed Systems Altener Contract Number: /C/00-002/2000

Figure 1: Uncovered and covered PVT collectors

Modeling and analyzing solar cooling systems in Polysun

Energy Intelligent Education

Hot water persons. Map section

Solar hot water systems in new housing

HIGH PERFORMANCE SOLAR THERMAL SOLUTIONS

LCoH Calculation Method: Comparison Between Task 54 and Solar Heat WorldWide

Tailor-made polymeric materials for collectors and heat storages

Project summary. 2 MW project Schalkwijk Haarlem Netherlands

Performance of a Solar Heating System with Photovoltaic Thermal Hybrid Collectors and Heat Pump

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Active solar heating system with concrete plate heating analysed with dynamical thermal simulations

Long-term monitoring and smart heat pumps for nzeb

Solar energy house with brine-water heat pump and PV. Map section

Lecture 4: Solar Thermal Heat Utilization

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

SolarKeymark-II. Large open EU market for solar thermal products. Deliverable D 18

Project Report: SunMaxx Commercial Case Studies

Australian Solar Cooling Interest Group (ausscig) Conference DHW/COOLING HYBRID STRATEGY FOR SOLAR COOLING:

Project Report: SunMaxx Commercial Case Studies

Project Report: SunMaxx Commercial Case Studies

FAÇADE AND ROOF INTEGRATED SOLAR COLLECTORS WITH A COMBINATION OF ELASTOMER TUBES AND METAL FORM SHEET ELEMENTS

YOUR SOLUTION FOR ENERGY EFFICIENCY

Demonstration building

Potential of Process Integration in four Industrial Companies in Germany

Active Solar Thermal Energy Applications in Buildings (Part 2)

SOLAR PHOTOVOLTAIC ENERGY

Camel Solar brings you some of the most advanced solar thermal systems available on the market today through innovation, research and development.

Challenges for Price Reduction of Solar Thermal Systems

Contributions of Solar Thermal to Energy Efficiency in the Tourism Sector

Solar Power. Technical Aspects and Environmental Impacts. 6 th March 2011 Sustainable Energy Options (UAU212F) - University of Iceland

PASSIVE HOUSE. is a building, which doesn t need an active type of heating. Dr. Ing Mihail Stancu

Technical specification. Selectively coated, %100 thermally contacted fins and absorbers for highly efficient solar thermal applications

SOLAR COMBISYSTEMS IN DENMARK SOLAR & BIOMASS SYSTEMS

Conversion Design of Solar Houses from Active to Passive

Danish national plans for Nearly Zero Energy Buildings

DESIGN AND RECOMMANDATIONS FOR DECENTRALIZED SOLAR DISTRICT HEATING SYSTEMS IN FRANCE

1/60. Solar systems. solar system layouts heat demand collector area calculation

New developed solar thermal systems for heating and cooling Budapest, 16 th April 2009 Tsekouras Panagiotis Mech. Engineer NTUA Centre for Renewable

Vaillant solar systems: The best solution for the sun.

The requirement system of the Hungarian directive on the energy performance of buildings

LAY OUT OF SYSTEMS High-flow and low-flow systems

Dipl.-Ing. Edmond D. Krecké, Luxembourg. 1. Starting position

Solar-Assisted Space Heating of a Highly Insulated Energy Efficient House

SolarKeymark-II. Large open EU market for solar thermal products. Deliverable D 15. Calculation procedures based on the EN

LIVING IN LIGHT BOX

LIVING IN LIGHT BOX

Comfort. Warm, Radiant. in the Sand. Floor heating systems that store the sun s energy in sand offer warmth through the cloudy winter.

Low energy buildings

Solar active school in Lajen (Italy) EURAC research - Institute for Renewable Energy Alexandra Troi

The District Energy Concept Adviser A Software Tool to support Urban Decision Makers in planning District Energy Supply Schemes

New Technologies and Opportunities for Solar Thermal Applications

THE ROAD TO NEARLY ZERO-ENERGY BUILDINGS

Local project in Dublin - IRELAND

Solar thermal technology taken to the next level

Energy Statement. Gainsford Road. For Pocket Living. XCO2 energy. May 2016

Energy & Financial Savings Analysis 12/01/10

Combisol project. Solar Combisystems Promotion and Standardisation

Laboratory Testing of Solar Combi System with Compact Long Term PCM Heat Storage

Cyprus Energy Agency. Nearly Zero Energy Buildings

Levelized Cost of Heat for Solar Thermal Systems with Overheating Prevention

INNOVATIVE METHODS TO ENCOURAGE BUILDING ENERGY EFFICIENCY IN FRANCE Francis Allard LaSIE, University of La Rochelle/CNRS

High Quality. UniPlate. Solar Collectors ENERGY SYSTEMS. Solartechnik Prüfung Forschung

EVALUATION OF A HIGH TEMPERATURE SOLAR THERMAL SEASONAL BOREHOLE STORAGE

Glazed photovoltaic-thermal component for building envelope structures

Solar Energy Today s Clean Energy Choice

Demonstration of the TESSe2b system in residential houses in Austria, Cyprus and Spain and their energy analysis

CONTENTS SUMMARY. The main advantages compared to state-of-technology drainback systems are that

5.5 kwh/m 2 day. Solar Thermal Systems. Solar Water Heater Story in Jordan. Flat plate collectors

EXECUTIVE SUMMARY: Best practices and lists of technologies to refurbish buildings & Proposed packages of measures

Performance Analysis of Glazed Liquid Photovoltaic-thermal Collector with Use of Detail Model

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

Side by side tests of two SDHW systems with solar collectors with and without antireflection treatment

Transcription:

Cost Reduction Potential of Polymeric Collectors Michaela Meir Aventa AS Journée R&D ADEME Sophia Antipolis, France 26 April 2018

Main differences to solar heating systems with conventional flat plate collectors Aluminium collector frame Polycarbonat collector cover twin-wall sheet Absorber i "high-performance polymers" (PPS) Thermal insulation Absorber endcap with interated manifold 2

Main differences to solar heating systems with conventional flat plate collectors Aluminium collector frame Polycarbonat collector cover twin-wall sheet Absorber i "high-performance polymers" (PPS) Thermal insulation Absorber endcap with interated manifold Collector High-temperature performance polymers Flexible lengths Light-weight building modules (8 kg/m 2 ) Replacing conventional building envelopes (roofs & facades) 3

Main differences to solar heating systems with conventional flat plate collectors Aluminium collector frame Polycarbonat collector cover twin-wall sheet Absorber i "high-performance polymers" (PPS) Thermal insulation Absorber endcap with interated manifold Collector High-temperature performance polymers Flexible lengths Light-weight building modules (8 kg/m 2 ) Replacing conventional building envelopes (roofs & facades) System Water as heat carrier High-flow system Drain-back technology Non-pressurized collector loop (installation) 4

Major Production Steps Structured sheet extrusion The number of production steps is significantly reduced compared to conventional solar collector production. Cutting End-cap assembly and coating Cutting of other sub-components Transport & installation 5

Absorber production Highly-industrialised processing Very few production steps Low production costs with high volume Integrated design Absorber of extruded structured sheets Top endcap Absorber (various lengths) IR welding Bottom endcap IR welding Standardized PEX-piping (floor heating) 6

Weight of components, Solar combisystem Average value of material (kg) "Combisystems 2008" with Conventional flat-plate collector Material weight comparison (in kg) Combisystem, Housing Estate Oslo: Polymeric AventaSolar collector 7

Solar Thermal Value Chain No wholesaler / distributor! B2B 1. Architecture + Energy Consultant 3. Distribution 2. Production 4. Installation Transport 5. Installed System 6. Operation and Maintenance 7. LCOHs 8

Total end-user costs (EURO) Prices of solar heating systems in private homes Total end-user costs incl. solar collector system and heat store, reported by the customers, include installation, but exclude VAT and subsidies. 15400 Prices for Solar systems in homes (2015) 13200 11100 8800 6600 4400 2200 Flat-plate collector Flat plate collector, non-pressurized Vacuum pipe collector Collect or area, gross (m 2 ) Collector area, gross Collector (m 2 ) area, gross (m 2 ) Collector area, gross (m 2 ) Savings due to replacement of other building envelope materials for building integration is not subtracted. Collector area, gross (m 2 ) 9

Cost examples: Medium-sized projects (1) Ilseng State Prison Costs: Solar collector, heat store, pumps, control system, pipes, removal of tiles, installation, engineering and administration. SUM: 433 /m 2 collector area 8.4 m 3 heat store, divided in 6 separate units SDHW-system with 237 m 2 solar collectors 10

Cost examples: Medium-sized projects (2) Bjørkelangen Elementary School Solar heating system for domestic hot water preparation. 105 m 2 facade integrated solar collectors 5.6 m 3 heat buffer store Costs Solar collector, heat store, pipes and controller, incl. installation: SUM: 370 /m 2 collector area Savings due to replacement of other materials/components are not included. 11

Cost examples: Solar combisystem (3) Housing Estate Oslo with 34 passive houses 34 houses with totally 480 m 2 roof integrated solar collectors, decentralized with 0.8 m 3 heat stores, incl.100 liters DHW preheater and piping, operation control of the auxiliary heat supply and solar heating system, installation- and start-up support. Costs SUM: 370 /m 2 collector area 12

Examples, Norway Lifetime 20 years Ilseng State Prison Retrofit, DHW preparation 237 m 2 Collector area 8.4 m 3 Heat store 1100 kwh/(m 2 a) solar irradiance* Bjørkelangen Elementary School New-built, DHW preparation 105 m 2 Collector area 5.6 m 3 Heat store 889 kwh/(m 2 a) solar irradiance* Housing Estate Oslo, 34 passive houses New-built, Solar combisystems with each 14 m 2 Collector area 0.8 m 3 Heat store 1210 kwh/(m 2 a) solar irradiance* * Solar irradiance on tilted collector surface. 13

Examples, Norway Lifetime 20 years Ilseng State Prison Retrofit, DHW preparation 237 m 2 Collector area 8.4 m 3 Heat store 1100 kwh/(m 2 a) solar irradiance* LCoHs_retrofit = 0.099 /kwh LCoHs_new built = 0.073 /kwh Bjørkelangen Elementary School New-built, DHW preparation 105 m 2 Collector area 5.6 m 3 Heat store 889 kwh/(m 2 a) solar irradiance* LCoHs = 0.035 /kwh Housing Estate Oslo, 34 passive houses New-built, Solar combisystems with each 14 m 2 Collector area 0.8 m 3 Heat store 1210 kwh/(m 2 a) solar irradiance* LCoHs = 0.082 /kwh Comments: Retrofit: roof tiles had to be removed * Solar Building irradiance is oriented on tilted collector towards surface. east High solar fraction 14 Electricity costs = 0.115 /kwh Comments: Good planning, infrastructure Comments: Passive houses: designed for high solar fraction Installation partly included

Thank you for your attention! Aventa AS Michaela Meir www.aventasolar.com mm@aventa.no 15