Powerful Insulation Sustainable and Efficient. A Study of Success from Ludwigshafen

Similar documents
THINKING ABOUT TOMORROW ALREADY TODAY RENEWABLE SOLUTIONS PAY OFF

Neopor in the web:

AS IMPORTANT FOR TODAY AS FOR TOMORROW- RESPONSIBLE SOLUTIONS

Additional information about Neopor. Brochure: Neopor Innovation in Insulation. Application brochure: Wall Insulation

Flachdächer. Karl-Heinz Schmitz. Reprint. Ernst & Sohn Special. April 2017, p A 61029

Neopor for flat roofs a prime example for sustainable construction

SBE16 Tallinn and Helsinki Conference

Apartment building Sodastraße 40 in Ludwigshafen, DE

Using Whole-life Costing Analysis for retrofits of low and high rise flats

Built examples and project certification. Zeno Bastian, Passive House Institute

CALCULATIONS OF COST-OPTIMAL LEVELS OF ENERGY PERFORMANCE REQUIREMENTS FOR RENOVATED BUILDINGS AND BUILDING ELEMENTS: A LATVIAN CASE

Wall Insulation. Neopor in the web:

Polyurethane: A key contribution to resource and energy efficiency

THE 3-LITER-HOUSE AN INNOVATION IN THE MODERNIZATION OF OLD PROPERTIES

Koniklecová 4, Brno-Nový Lískovec

Energy Efficient Buildings in Germany An Introduction

Pilot Project Efficient Homes

Improving energy efficiency in buildings. Matthias Hensel Senior Vice President Managing Director of BASF Real Estate Company LUWOGE

Facade Insulation. Introduction. Roger Malmquist,

City of Vancouver Land Use and Development Policies and Guidelines

Editorial 2. Quality Products from BASF The Benchmark in Polystyrene For Over 50 years. Neopor. Styropor. Table of Contents

The Nottingham Ecohome. Part L1 (2002) in existing dwellings

Mass Balance. Raising the share of renewables for your products. Mass Balance Solution for BASF Performance Materials Construction.

First European Energy Efficiency and Behaviour Conference, Maastricht, October 19th-20th, 2009

Efficient and smart climate shell. refurbishment of residential buildings PART OF SMART SOLUTION 1: EFFICIENT AND SMART CLIMATE SHELL REFURBISHMENT

Building Performance Evaluation

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Improved perceived indoor environment in renovated and energyretrofitted

5 social row houses (Wachtebeke)

Building and Modernizing with Neopor

Torben Lundberg Architect m.a.a

BALCONY & FAÇADE DESIGN

Healthy Living Heat out, Healthy Living in. Summer Heat Protection. engineered by nature

1. Introduction. Carl-Magnus Capener, Ph.D. 1 Stephen Burke, Ph.D. 2 Simon Le Roux, Architect 3 Stephan Ott, Architect 4

External Wall Insulation Systems GUARANTEED TO PERFORM!

Methodology, Calculations and Results

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Upgrade your Home Insulation

World Materials Forum Nancy, June 23 rd, 2015 Martin Brettenthaler CEO of PAVATEX Group

The benefits of polyurethane insulation Today s solution for tomorrow s needs

Now our house. saves soooo. much energy! T h e N e w G e n e r a t i o n Energy Saving. S y s t e m. The Quality Profile

Project Description. Projected build start date 12 Apr 2010 Projected date of occupation 28 Feb

The Centre for Sustainable Building (ZUB) * A Case Study

WP6. ENERGY REFURBISHMENT BUILDINGS

exceed your energy performance levels

SMS RETROFIT & PARTNERSHIP DELIVERY FRAMEWORK. An Introduction for SHAP Members

Passive House: Overview

Energy Efficiency in Berlin s Housing Stock

Polyurethane spray insulation

Research Analysis: Building Envelope and LEED Credits Introduction

RETROFIT BUILDINGS CLOSE TO PASSIVE HOUSE STANDARD

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

ANNEX 4 LONG-TERM PLAN FOR THE RENOVATION OF THE NATIONAL BUILDING STOCK CHAPTER I INTRODUCTION

Fire safety issues with balconies

Energy Performance Certificate

Forty years of building physics research for what benefit?

Minimum Energy Consumption 84% energy heating savings*

Training for Renovated Energy Efficient Social housing. Intelligent Energy -Europe programme, contract n EIE/05/110/SI

HOMEGA DESCRIPTION. UNIQUE PATENTED PRODUCT ON THE MARKET US Patent No CAN Patent No

Glaciers are melting, sea levels are rising, cloud forests are drying, and wildlife is scrambling to keep pace.

2018 annual report in accordance with Article 24(1) of the EED

About Insulation & R Value - cmhc.ca

APT building on Makartstrase, Linz AT

Editorial. Quality Products from BASF The Benchmark in Polystyrene For Over 50 years. Neopor. Styropor. Table of Contents

PHPP Report. Beattie Passive Inchkeith Drive

Keep your home. FREE from DAMP, CONDENSATION and MOULD

Cost-Benefit Analysis of Dwelling Retrofit Options

CASE STUDIES - CENTRE FOR SUSTAINABLE BUILDING (ZUB) KASSEL, GERMANY

Passive House: Overview

NEWS LETTER MARCH 27, 2009

Unleash your creativity with natural materials! A guide for Architects

Dipl.-Ing. Edmond D. Krecké, Luxembourg. 1. Starting position

ROW - Albertslund, DK

Guidance on U Values from Domestic Heating Design Guide

Building Sustainability Why Passive House?

WaMaFat. Integriertes Wärmemanagement- Fassadenelement. BMWI gefördertes Projekt (seit 6/2011)

Achieving the nearly zero energy building concept - A study based on practical experience

Kindergarten Vejtoften, Høje-Taastrup, Denmark

Building blocks for your ideas

HEALTHY LIVING. invisible but measurable

Single family low energy house, Herselt, Belgium

Effective Date: April 25, 2016 Revised: November 7, 2017

the smart solution for your façade insulation

Nearly zero energy building renovation, the EU-GUGLE project Javier Llorente Yoldi

DIATHONITE EVOLUTION INSULATION PLASTER. Eco-friendly Clay and Cork-Based Plaster with Exceptional Thermal and Sound Insulation Properties

Breathability of building elements

Industrial services. Heat insulation. Industry. Great potential for savings with classic insulation.

News Release. New welding technology for thick insulation boards

Performance You Can Rely On Smart Insulation by Neopor Plus GPS.

PassivTEN - Scottish Tenements and the Passivhaus Standard

Learnings from residential PH design and procurement in Australia. Luc Plowman

4/13 Ministry of the Environment degree

Special Applications of ETICS. Wolfgang Setzler, General Manager Fachverband Wärmedämm- Verbundsysteme e.v.

Alternative Heating Sources

What you need to know about 6 Star. 6 Star. for new homes, home renovations, alterations, additions and relocations

Mohammed Ibrahim Daher. Amman, Jordan

Energy Efficiency in Buildings Berlin s Role

Energy Performance Certificate

Covering (Month/Year): January/2012 Submitted (date): 06/02/2012. Cotentin, Paris, France. van der Lelijstraat, Delft, the Netherlands

Transcription:

Powerful Insulation Sustainable and Efficient A Study of Success from Ludwigshafen

Page 03 THE BRUNCK DISTRICT: AN INTEGRATED CONCEPT In collaboration with the Ministry of Finance of the German State of Rhineland-Palatinate and various scientific institutions, the partners BASF SE and LUWOGE devised a longterm and comprehensive concept for modernisation of the Brunck district in the centre of Ludwigshafen. This settlement for workers, which was created in the 1930s on the doorstep of the BASF site, was revitalised in its entirety from 1997 to 2006. The new and modernised buildings were provided with innovative system solutions in the areas of thermal insulation and renewable energies in order to achieve maximum scores for energy and eco-efficiency. For the first time, a external thermal insulation composite system (ETICS) comprising insulating material panels made of Neopor from thermal conductivity group 035 was used and, compared to conventional EPS insulating materials, it displays insulation performance that is up to 20 per cent better. The economic, ecological and socio-cultural objectives were finally examined in a long-term study, as part of the sustainable revitalization of the district. The goal was to validate the desired advantages of the sustainable structures and to continue with these in the future. Aerial shot of the modernised existing properties (3, 5, 7 litre houses) and the 1 litre houses (new build) in the Brunck district in Ludwigshafen The Brunck district: This settlement for workers dating from the 1930s was completely revitalised from 1997 to 2006. THE BRUNCK DISTRICT: Example of a major contribution to sustainable construction The Brunck district in Ludwigshafen consists of 500 dwellings, most of which are blocks housing multiple flats. Back in the mid-1990s, it became apparent that the existing dwellings were in great need of renovation. This heralded the start of a pilot project in which BASF together with LUWOGE renovated the existing building stock up to the 3, 5 and 7 Litre standard, and designed new 1 litre house. This unique project allows us to answer a number of questions which are repeatedly asked in relation to EPS insulation: The Brunck district: an integrated concept Page 03 Costs put to the test: Is insulation worth it? Page 04 Does it last? Lifespan and durability of facade insulation Page 06 Climate protection, energy efficiency and resource conservation: How ecological is EPS insulation? Page 07 Greener living = better living? Studies of quality of living Page 08 Is it safe? How do EPS insulation materials behave in a fire? Page 10 New build Planned new build New build of 1 litre townhouses 3 litre house in old building Old building renovation Diagrammatic representation of the revitalisation measures

Page 04 Page 05 COSTS PUT TO THE TEST: IS INSULATION WORTH IT? A comparison of the measures implemented in the Brunck district in order to increase the level of energy efficiency shows that, depending on the type of building, the payback periods for insulation measures in the basement ceiling, the roof and the external wall are between eight and 17 years. The payback period represents a key parameter for assessing the economic viability of energy efficiency measures. It defines the period at the end of which the costs saved as a result of the reduction in energy will exceed the level of investments made in energy-related building work. The Brunck district case study shows that energy efficiency measures benefit both tenants and landlords equally. Various factors need to be taken into account here. The condition of the property prior to renovation plays a major role. The rule of thumb here is that, the greater the need for renovation, the higher the initial investment but also the greater the potential to save energy. If energy-related renovation is carried out as part of repair works that were required anyway, it usually does not account for more than 35% of the total costs. So if a building needs to have a new render applied to it, direct consideration should be given to facade insulation in order to save costs in the long run. In this connection, Werner Eicke-Hennig, an energy expert from the Energy Saving Campaign organised by the German state of Hesse, clearly summarises the situation: If you are put off by constant false messages, you are losing real cash. If you do not implement energysaving measures on your property, you are throwing your money out of the window on ever-rising heating costs. Facade insulation is also of interest to tenants. This is because in new buildings and in the renovation of existing ones it is possible to considerably reduce heating energy consumption. Although some of the costs of modernising the building are apportioned to rents excluding heating charges, the saving in the ancillary costs usually more than compensates for this increase. Besides the higher quality of life that a renovated apartment offers, tenants also benefit from a fall in rents including heating charges. When it comes to new buildings, the payback period is essentially dependent on the target energy efficiency level that the new building is seeking to achieve. The rule here is that the more ambitious the energy specifications in relation to the energy efficiency levels stipulated by the German Energy Efficiency Ordinance (EnEV), which are already very good, the longer the payback period for individual energy-related measures. Using the five litre house in a new build in the Brunck district as an example, the different insulation measures had payback periods of just five to seven years. Section of 3 litre house 1 Economic efficiency of energy-related renovations in 2013 1 [3 litre house] 100.000 50.000 0 2013 2018 2023 2028 2033 2038 2043-50.000-100.000 External wall insulation Basement ceiling insulation Roof insulation Windows (double glazed) Payback profile for the individual energy-related modernisation measures in a 3 litre house based on today s economic climate (2013) Payback period of the investment costs - comparison of energy-related modernisation from 2001 to 2013 1 [3 litre house] IMPORTANT INFORMATION ON THE COSTS OF ENERGY-RELATED BUILDING WORK 50 a In the case of renovation: If you combine building work, you save costs: Insulation of the facade can take place, for example, as part of replacement of the render that needed to be carried out anyway. This produces considerable savings. It should also be noted that the complexity of the building and the original condition of the building from an energy point of view have a crucial bearing on the costs and therefore also on the payback period. In the case of new builds: The desired energy efficiency target for the building firstly dictates the level of investment, but also dictates the level of savings that can be made. 40 a 30 a 20 a 10 a In the case of new builds and renovation, it is essential to plan the works carefully. They should be carried out by specialist experts. It is advisable to recruit an energy specialist to do the planning because complex conditions such as the geographical location of the property or coordination of the technical facilities with the shell of the building need to be considered if the building work is to be sustainable. a External wall insulation Roof insulation Basement ceiling insulation Windows (triple glazed) Calculation on the basis of data for 2001 Calculation on the basis of data for 2013 Comparison of the payback periods for individual energy-related modernisation measures in a 3 litre house (existing) based on changes to the economic climate

Page 06 Page 07 DOES IT LAST? LIFESPAN AND DURABILITY OF FACADE INSULATION CLIMATE PROTECTION, ENERGY EFFICIENCY AND RESOURCE CONSERVATION: HOW ECOLOGICAL IS EPS INSULATION? An investment in facade insulation and in all energy-related renovation measures in general is always a long-term investment. Despite this, the shortest possible payback period is of course desired. This is why as part of the monitoring for the Brunck district we also scrutinised the technical condition of the insulation system in greater detail more than ten years after the renovation work was carried out. An expert report prepared by an independent specialist in 2012 revealed that the thermal insulation measures which were implemented did not display any notable signs of wear and tear. An analysis of thermal images of the different buildings also showed that the buildings insulated with Neopor did not have any new thermal bridges even after ten years. The expert did not identify any signs of algae formation either. The fact that EPS insulation systems have already been employed and consistently developed further over the space of 50 years also offers peace of mind. The Fraunhofer Institute for Building Physics carried out a study into the durability of thermal insulation composite systems and reached the following conclusion 2 : If maintained properly, the lifespan can be categorised as being the same as that of rendered brickwork. This equates to a lifespan of between 40 and 50 years. Around 40% of all the energy consumption in the whole of society in Germany is produced in the housing sector. The example of the Brunck district in Ludwigshafen shows that an integrated overall energy concept makes a substantial contribution to reducing CO 2 emissions. In an ideal situation, appropriate insulating measures in combination with triple-glazed windows and a controlled ventilation system with heat recovery can reduce the demand for thermal heat and CO 2 emissions by more than 80 per cent compared to a building which has not been renovated. Spread over the whole of the revitalised Brunck district, it has thus been possible over the last ten years to save around 8,300 tons of CO 2 emissions and depending on the type of building between 70 per cent and 86 per cent of the energy demand. The 7, 5, and 3 litre houses in the existing stock save 387,000 litres of heating oil per year, which is equivalent to 13 full lorry loads. The balance of what is known as grey energy (the energy consumed during the production and logistics processes for an insulating material) in relation to the energy savings achieved is also extremely positive, as the example of the Brunck district demonstrates: the grey energy is compensated by the savings in heating energy after around one year. After this, future energy savings will make a lasting contribution to relieving the impact on the environment and to achieving independence from reliance on the import of fossil fuels. With suitable insulation measures it is possible to save up to 80% of CO 2 emissions. Thanks to the modernisation, 387,000 litres of heating oil are saved every year in the Brunck district. After taking account of the energy consumed in the manufacturing process, the life cycle assessment is still positive. Studies confirm that insulation with EPS also makes sense from an ecological perspective CO 2 assessment over 10 years 3 litre house 1 130 t 80 t 30 t -20 t External wall insulation Roof insulation Basement ceiling insulation Grey energy [t CO 2 ] CO 2 saving [t/10a] New windows Eco-efficiency analysis of various insulating materials Environmental impact (norm.) 0,7 1,0 The diagram arranges the insulating materials in terms of their economic efficiency and effects on the environment in relation to 1 m² of a thermal insulation composite system with a U value of 0.15 W/m²K viewed across the entire life cycle (raw material, production, logistics, processing, lifespan, disposal). Neopor 032 Neopor 035 Styropor 035 Mineral wool 035 Mineral wool 040 The expert report on the building stock drawn up in 2012 could not identify any significant signs of aging or algae growth. 1,3 1,3 1,0 Costs (norm.) 0,7 BASF eco-efficiency analysis 2013 validated by TÜV Rheinland

Page 08 GREENER LIVING = BETTER LIVING? STUDIES OF QUALITY OF LIVING In our climatic zone, it is generally good for the heat to remain within a building. This is why we pretty much never have to heat, only on a few very cold days in winter.[...] For us the insulation and ventilation system has only brought benefits. Peter Doland, tenant in Brunck district Our everyday quality of life is partly determined to a significant extent by the comfort of the living environment that we subjectively perceive. The proper management of an energy-efficient building requires a disciplined and methodical approach to be adopted by the residents: In well-insulated buildings, it is particularly important to exercise proper ventilation practices in order to guarantee healthy air quality and prevent great fluctuations in temperature in the living rooms. Residents who additionally have a modern ventilation system also report that the air inside the building is more or less free of any dust and pollen. All in all, around 80 percent of the residents of the Brunck district were satisfied with the quality of the climate inside their dwellings, which have been modernised from an energy point of view, with just 7 per cent finding the indoor climate unpleasant. EPS insulation is also no worse than alternative systems when it comes to mould infestation. The experiences of specialist energy consultants and the studies conducted in the Brunck district show that EPS-insulated buildings are not affected by mould to any greater extent than buildings without any facade insulation. On the contrary, properly fitted EPS facade insulation can even help to prevent mould. Here too the importance of professional installation is apparent. Mould is usually caused in the insulation by incorrectly positioned wall plugs or insulation panels which are damaged during installation. In addition, two thirds of the residents surveyed indicated that the new visual attractiveness of the residential area as a whole had also had a significant positive influence on their personal sense of quality of living. 1 Survey results regarding the climatic well-being of inhabitants: How comfortable do you feel in your dwelling that has undergone energy-related modernisation? 1 60 % 50 % 40 % 30 % 20 % 10 % 0 % Very comfortable Comfortable Neutral Uncomfortable Very uncomfortable Climatic wellbeing

Page 10 IS IT SAFE? HOW DO EPS INSULATION MATERIALS BEHAVE IN A FIRE? so that a facade which is insulated with EPS, for example, cannot be set on fire by a welding spark, a firework or cigarette ends even if the protective layer of plaster has not yet been completed. In the case of a thermal insulation composite system (ETICS) which has been properly completed, the insulation can only catch fire if a fire burns for an extremely long period of time and intensely, for example if a rubbish skip or a pile of bulk refuse is on fire close to a facade. The fire safety is guaranteed because strict regulations in relation to fire prevention need to be complied with in the insulation of buildings: Licensing requirement for all building products used Numerous material tests in the laboratory and on original scale prior to market launch Prescribed structural measures (fire barriers) in buildings in which the floor of the highest occupied level is at a height of more than seven metres Correct processing by a skilled installer also ensures the safety of EPS facades. In the recent past, concerns have repeatedly been raised about the resistance of EPS insulation materials to fire and heat. Werner Eicke-Hennig, head of the Energy Saving Campaign organised by the German state of Hesse, puts the frequency of fires in which an EPS facade was involved into proportion: Fires per year in Germany: Based on research by the Hessian Energy Saving Campaign Total 180,000 Of the 180 000 fires per year, installed flame retardant insulation materials are only involved with a percentage of 0,025. In these incidents the material were never the cause of the fire. The fact is that EPS is an organic material just like wood and is therefore combustible. For building purposes, EPS is employed in Germany exclusively as a flame-retardant product with ETICS 4 If you opt for certified and tested insulating materials at the planning stage, you will not only save money in the long run but also enhance your quality of life and living environment. What has been highlighted here using an entire residential district is of course also relevant to people who wish to develop their own homes. For they have the ability themselves to plan and implement energy-related measures on a sensible scale. Sourcest: 1 LUWOGE Consult: Langzeitmonitoring Brunckviertel (2013) Long-term monitoring of Brunck district (2013) 2 IBP Notification 24 (1997), No. 316 On the one hand, questions relating to energy-related renovation can never simply be answered with one general response, but on the other hand the answer it depends is very unsatisfactory. Particularly as an energy-related measure always has to be assessed within the overall context of the building as a system, it makes sense to seek the advice of an expert. This can be provided by the trained craftsman or certified specialist energy consultants.

Important note The data contained in this publication is based on our current knowledge and experience and refers exclusively to our product with its properties at the time this document was prepared; no guarantee or contractually agreed properties of the product may be inferred from our information. When using it, the special conditions of the application must always be taken into consideration, especially as regards building physics, building technology, and building law. PMEF 1502 BE