Dionex ICS-6000 Consumables Tracking Quick Start Guide

Similar documents
Practical guidance for switching between anion and cation analysis systems

Effect of Temperature on IC Signal Noise

Configuring the Dionex Modular HPIC system with an inline water purifier and inline calibration for trace anion determinations in ultrapure water

Determination of Inorganic Anions in Acid Rain Using a Dedicated High-Pressure Capillary Ion Chromatography System

Configuring a High-Pressure Dedicated Capillary IC System for Electrochemical Detection

Service Plan Creator. Quick Reference Guide RapidFire Tools, Inc. All rights reserved. V Ver 1I

Thermo Scientific Dionex ICS-900 Ion Chromatography System

Intelligent LC: Advanced control

Integrated IC Systems Installation Qualification Dionex Corporation

Continuously Regenerated Trap (CR-TC 500, Capillary)

Configuring the Dionex Integrion HPIC system for trace anion determinations in ultrapure water

CPOD Goal Module User Guide For the Talent Management System

Implementation of a Walk-Up High- Pressure Capillary Ion Chromatograph for the Fast Separation of Pharmaceutical Relevant Inorganic Anions and Cations

DCMS Link 2.10 for Compass / HyStar

In-Cell and External Hydrolysis of Biomass for Carbohydrate Determinations Using Automated Solvent Extraction

SAMPLE - Not to be Reproduced. designed by Regina Rexrode

New Developments in Capillary Ion Chromatography Systems with Electrochemical Detection and Their Applications

Dual EGC A simple solution for complex carbohydrate analysis

SAGE ACCPAC. Sage Accpac ERP. Lot Tracking 5.5A. Update Notice

Eluent Generator Cartridges

Controlling the Agilent 1260 Infinity/1290 Infinity II Multisampler (G7167A/B) in Waters Empower 3 Environment

( ) IONPAC ATC-HC ANION TRAP COLUMN

Quick Start Guide. Corporation Rev. 1

Elevator control setup with Entrapass Special or Corporate edition with KT-400

Thermo Scientific Dionex DRS 600 Dynamically Regenerated Suppressor

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

CHAPTER 10 ACQUISITION AND PAYMENTS

Agilent Infinity LC Instrument Component Software Version 1.0 for Empower Software

Item Transfers. SIMMS Inventory Management Software 7.3. November 22, 2010

Thermo Scientific Dionex ICS-4000 Integrated Capillary HPIC System. Always ready, better results. capillary high-pressure ion chromatography

Inventory Replenishment

UM0925 User manual. Using the M24LR64-R datalogger reference design. Introduction

Set-up, programming and analysis MagNA Pure 96 (Roche)

TRACE 1300 and TRACE 1310 Gas Chromatographs Dual Detector Microfluidics Installation Guide

Version 2.8 Release Notes

Data Box. Quick User Guide

Assay for Citrate and Phosphate in Pharmaceutical Formulations Using a High-Pressure Compact Ion Chromatography System

Analytical Products and Solutions

Options Eluent Regeneration (RFIC-ER ) Column Heater In-Line Vacuum Degas Full Chromeleon Chromatography Data System

IBM Maximo Mobile Suite Version 7 Release 5.1. User Guide

Fujitsu RFID Integrated Label Solution. First Step Guide. November 2015 Version 1.21 A698HL EN

DIGITAL VERSION. Microsoft EXCEL Level 2 TRAINER APPROVED

Dionex Eluent Generator Cartridges

How to Implement and Use Electronic Documents with SAP Business One

User s Guide for USB Connection Patrol System

Next generation suppressor for ion chromatography. Thermo Scientific Dionex ERS 500 Electrolytically Regenerated Suppressor

Dionex DRS 600 Suppressor Dionex ERS 500e Suppressor Dionex ERS 500 Carbonate Suppressor

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

AECOsim Building Designer. Quick Start Guide. Chapter A09 Modeling Interior Walls Bentley Systems, Incorporated

Decor Fusion Inventory Handheld Gun Usage Guide Version Date [Publish Date]

Complete Customer Support

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

Course Companion E-Z Data, Inc. All rights reserved. SmartOffice is a registered trademark of E-Z Data, Inc.

Warehouse Management System for Adagio Accounting

Lab 2: Work Management From Service Request to Work Completion

electrochemical detection

Inspection Process for Inventory and Consumable Material

Verify if a device can stand all kinds of protocol variations

Table of Contents. Contents. Introduction. Program Setup. Locations. Warehouses. Company Settings. PM Schedule Templates.

Short Tutorial for OROS Quick

Solar Product Cutting. Release 8.7.2

Integrating PPC s SMART Practice Aids with Engagement CS (Best Practices)

User Manual QProg Lite

Be a pioneer. Thermo Scientific Dionex ICS-6000 HPIC system the freedom to explore

Cipher Lab 8200 Installation & Usage Guide

COMPUTERIZED ACCOUNTING

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

User Guide. ARE H9 Full-ISO Pocket Reader

BEST PRACTICES. SMART Audit Suite with Engagement CS. Table of Contents. Integrating SMART Audit Suite Working with the SMART Suite...

SMARTSCAN 8000 SERIES MUTE MODULES Series Mute Accessories Installation Sheet ( CD174A and CD174B )

PUBLIC. How to Work with the SBO Mailer Signature. All Countries. Solutions from SAP. SAP Business One 2007 B. June English

Autodesk Revit Structure 2013 Fundamentals

Introduction. Yan Liu, Victor Barreto, Rosanne Slingsby, Chris Pohl Thermo Fisher Scientific, Sunnyvale, CA, USA

SmartFulfillment User Guide

Module Simple Barcode Inventory User Manual Version 1.0

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

Analysis of Fracking Flowback Water From the Marcellus Shale Using In-line Conductivity, Automated Dilution, and Ion Chromatography

Determination of Manganese in Brine ( 30% NaCl)

Certify User Guide INVOICE REPORTS

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

Creating products manually

BP(A S) Taleo Performance User Guide

PRODUCT MANUAL FOR THE. ELECTROLYTIC ph MODIFIER (EPM) EPM, P/N

Vacancy/Requisition Process Hiring Managers

Unit 1, 176 Forest Rd, Hurstville NSW USB Logger User Guide

Input example for the modules acc. to DIN EN Lauterbach Verfahrenstechnik GmbH

Applied Biosystems Thermal Cycler Remote Access User Guide

X2-RCU (Robot Control Unit) BE-5132 User Guide V1.0

Inventory Control Receive Inventory from McKesson

Microsoft Dynamics GP. Inventory Inflation Adjustment

TIKOS. Base program Order processing BUSINESS SOLUTIONS. Copyright SoCom Informationssysteme GmbH 2017, All rights reserved

Version Software User Guide

Performance Maintenance Protocol

USING QUANTIFY WITH QUICKBOOKS

GV-Data Capture V2 User's Manual

Conducting Inventory. Full Inventory Reference Guide

Logistics Guide. Avontus Software Corporation Avontus.com US AUS. Page 1

Microsoft Office Project 2010 Basic Course 01: Getting Started

Transcription:

Dionex ICS-6000 Consumables Tracking Quick Start Guide Many of the non-powered consumables (including analytical columns and chemically-regenerated suppressors) used with the Thermo Scientific Dionex ICS-6000 Ion Chromatography System are capable of RFID (radio-frequency identification) communication. The Consumable Device Monitor (CDM), a smart RFID controller, provides the necessary interface to these consumables. When installed in the Thermo Scientific Dionex ICS-6000 Detector/ Chromatography Compartment (DC) and configured in the Thermo Scientific Dionex Chromeleon 7 Chromatography Data System, the CDM can automatically identify RFID-enabled consumables and track various usage parameters. Setting Up Consumable Tracking To configure the CDM 1. Check the DC rear panel to verify that the CDM is connected to a USB port on the CPU board (see Figure 1). The USB cable (P/N 00302-99-00132) required for the connection is provided in the Consumable Device Monitor Kit (P/N 22181-60031). Figure 1. DC rear panel: Consumable Device Monitor connection to DC CPU DC CPU Consumable Device Monitor USB Cable USB Cable 2. In the Chromeleon Instrument Configuration Manager, right-click the Dionex ICS-6000 instrument to which you want to assign the CDM and click Properties. The Add module to instrument dialog box appears (see Figure 2). a. Under Manufacturers, select the Dionex ICS-6000 instrument to which you want to assign the CDM. b. Under Modules, select Consumable Device Monitor (ICS-6000). c. Click OK. Document No. 065759-01 February 2018 2018 Thermo Fisher Scientific Inc. All rights reserved.

Figure 2. Add module to instrument dialog box 3. Right-click the CDM in the instrument tree. The Properties dialog box for the CDM appears. 4. On the General tab page, select Live mode (see Figure 3). Figure 3. CDM Properties dialog box: General tab page 2

5. On the Sharing tab page, select the check box for each instrument that will share the CDM (see Figure 4). Figure 4. CDM Properties dialog box: Sharing tab page 6. Click OK. To inspect RFID tag location and orientation 1. Install and plumb the consumables as required for your application. 2. To optimize RFID connectivity, check the RFID tag attached to each consumable to verify that these criteria are met: Columns should be installed in column clips. RFID tags should not touch the clips. RFID tags should be free in the air (for example, a tag must not be wrapped around a separator or guard column). RFID tags should be spaced far enough apart that the tags do not overlap. RFID tags should not touch bare metal. RFID tags should not be in direct contact with the floor, ceiling, sides, or front door of the DC. RFID tags should be parallel to the floor of the DC. RFID tags can extend toward the front or rear of the DC. The following illustrations depict the correct installation of RFID tags: Figure 5 shows the ideal orientation: RFID tags are parallel to the floor of the DC, and point to both the front and rear of the module. Figure 6 is a close-up view of RFID tags attached to columns. Note that tags can be rotated underneath columns (to ensure that the tags do not touch the ceiling of the DC) and extend toward the valve panel at the rear of the module. 3

Figure 5. RFID tags parallel to the DC floor RFID Tags Figure 6. RFID tags on underside of columns RFID Tags To scan consumables 1. In Chromeleon, click the Rescan button in the Consumables Inventory window. It may take up to 3 minutes for all consumables to be scanned; during this time, you may close the inventory window and perform other tasks in Chromeleon. Note The names of any previously detected consumables may temporarily turn red while scanning is in progress. This does not indicate a problem. 2. When all trackable consumables have been scanned, check the results in the Consumables Inventory window. If a newly installed consumable is not listed, refer to RFID Communication Error (see Chapter 9 of the Dionex ICS-6000 operator s manual) for help. Adjust RFID tags as needed, and then click Rescan again. To select consumables to be tracked For each consumable to be tracked, click the corresponding Tracked check box in the Consumables Inventory window (see Figure 7). 4

Figure 7. Consumables Inventory window If this is a standard single system (one flow path) or standard dual system, accept the default information in the Groups column. Note If more than one flow path or channel is configured in the same Chromeleon instrument (as with simultaneous and column switching applications), two consumable groups must be created. For instructions, refer to the Dionex ICS-6000 operator s manual or the Chromeleon Help. A lock icon in a Tracked check box indicates that the consumable is currently assigned to another instrument (second flow path) and cannot be selected. Do not click the corresponding Tracked check box for any consumable that will be used in another instrument or channel. These consumables should be selected from the Consumables Inventory window of the other instrument. Consumables that use wired communication (including eluent generator cartridges and suppressors) are automatically connected and do not need to be selected. To assign the temperature zone for a consumable 1. Click Thermal Assoc. The Consumable Properties dialog box appears (see Figure 8). Figure 8. Consumable Properties dialog box 2. Select the compartment in which the consumable is installed: Compartment_TC is the DC upper zone (with the detectors) Column_TC is the DC lower zone (with the injection valves) 3. Click OK. 5

To confirm all installed consumables Click the Approve button in the Consumables Inventory window. Note For a dual system, repeat the above procedures for the second instrument/channel. Removal and Storage of Consumables Contacting Us Trademarks To remove and store a consumable Before removing a trackable consumable from the system, click the Store button in the Consumables Inventory window. This writes the latest system data to the RFID tag attached to the consumable. To contact Technical Support for Dionex products In the U.S. and Canada, call 1-800-532-4752. Outside the U.S. and Canada, call the nearest Thermo Fisher Scientific office. Chromeleon is a registered trademark of Thermo Fisher Scientific Inc. in the United States. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. 6