SECTION BATTEN SEAM COPPER ROOFING

Similar documents
SECTION COPPER STANDING SEAM ROOFING

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

SECTION ROOF SPECIALTIES

SECTION BUILT-UP BITUMINOUS WATERPROOFING

Architectural Wall Products Guide Specifications

SRP-AirOutshield ROOF Issued:

SECTION ASPHALT SHINGLE ROOFING SYSTEMS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

FORTIFIED Home High Wind. Bronze New Roof Requirements

SECTION STANDING-SEAM METAL ROOF PANEL

SECTION STANDING SEAM METAL ROOFING

SSL-175. Specifications

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

Product Guide Specification

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION ROOF AND DECK INSULATION

DL-200. Specifications

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

SECTION SHEET MEMBRANE ROOFING

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

SECTION CLAY BARREL TILE ROOFING Removals Flashing and Sheet Metal.

Distributed by: BEST MATERIALS LLC Ph: , Fax:

Sheet Metal Flashing and Trim

DIVISION 7 THERMAL AND MOISTURE PROTECTION

ROOF ASSEMBLIES CHAPTER 9

SECTION ROOFING AND SIDING PANELS

SECTION ROOF SPECIALTIES

SECTION STEEL DECKING

STONE COATED METAL ROOF SHINGLE

TECHNICAL INFORMATION

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.

ZARA & ASSOCIATES, INC. Peter L. Zara 8435 Sunrise Lake Blvd -# Sunrise, Florida Phone

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION CONCRETE TILE ROOFING. A. American Society for Testing and Materials (ASTM):

1 Exam Prep NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012 Tabs and Highlights

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Update In Progress. Division 7 Thermal and Moisture Protection Page Section ROOFING AND WATERPROOFING

EVALUATION REPORT Boral Roofing /MonierLifetile 7575 Irvine Center Drive Suite 100 Irvine, CA

SECTION METAL ROOF AND SOFFIT PANELS

SECTION CEMENTITIOUS WOOD FIBER DECKS

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):

SRP-AirOutshield UV Issued:

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

University of Louisville February 22, 2017 Papa John s Cardinal Stadium -North Expansion Bid Package No. 5 Louisville, Kentucky

Metal Roof Panels

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Hawthorne Fire Station Repairs Section Page 1 of 8

ROOF ASSEMBLIES CHAPTER 9

Section Pre-Applied Sheet Membrane Waterproofing

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SECTION METAL FLAT LOCK TILE PANELS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

ROOF ASSEMBLIES CHAPTER 9

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

ARCHITECTS & SPECIFIERS : SHINGLES, TILES, & ROOF COVERINGS

SECTION FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Product Guide Specification

SECTION ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

ROOF ASSEMBLIES CHAPTER 9

SHEET METAL ROOF TEST REPORT

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

ROOFING APPLICATION STANDARD (RAS) No. 118 INSTALLATION OF MECHANICALLY FASTENED ROOF TILE SYSTEMS Direct Deck & Counter Battens Only

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

University of New Hampshire Scholars' Repository

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

SECTION TURBINE VENTILATORS

3. Roof Expansion Joints between New Building and Existing Building.

CRCA Education Series. Self-Adhering Membrane Roofing Systems for Low Slope Roofs

SECTION 7307 CONCRETE/ CLAY TILE, METAL, SLATE AND ASPHALT COMPOSITION SELF-ADHERED/ PEEL & STICK ROOF UNDERLAYMENT

Slate. Material description

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION ADHERED SINGLE PLY MEMBRANE ROOFING

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

Henry Self-Adhering Roofing Underlayments. self-adhering. roofing underlayments DESIGNED FOR: Shingles. Tile. Metal. Slate

Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood

SECTION FLASHING AND SHEET METAL

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

SECTION MANUFACTURED ROOF EXPANSION JOINTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

Transcription:

PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 07 61 16 BATTEN SEAM COPPER ROOFING SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph as required and renumber the paragraphs. 2. Use for roofing sloped 1 in 4 (3 in/ft.) or greater. A. This section specifies the installation of batten seam copper roofing. 1.2 RELATED WORK: //A. Sustainable Design Requirements: Section 01 81 13, SUSTAINABLE DESIGN REQUIREMENTS. // B. Sealant: Section 07 92 00, JOINT SEALANTS. 1.3 SUBMITTALS: A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. //B. Sustainable Design Submittals, as described below: //1. Postconsumer and preconsumer recycled content as specified in PART 2 - PRODUCTS.// // C. Fabricator s qualifications. D. Installer qualifications. E. Manufacturers literature, data, for copper, underlayment, sealant and accessories. F. Submit shop and erection drawings containing data necessary to clearly describe design, materials, sizes, layouts, seam configuration, construction details, provisions for thermal movement, line of panels, fastener sizes and spacings, sealants and installation procedures. Show waterproof connections to adjoining work; show obstruction and penetration details. G. Samples consisting of 152 mm (6 inch) or 305 mm (12 inch) square specimens of specified copper roofing material. 1.4 WIND UPLIFT LOADS: A. Provide roof assemblies meeting uplift pressures using a basic wind speed of // // km per hour (// // miles per hour), an importance factor of // //, and an exposure of // //. 07 61 16-1

1.5 QUALITY ASSURANCE: A. Fabricator s Qualifications: Company specializing in copper sheet metal roofing work with three (3) years experience in similar size and type of installations. Submit qualifications. B. Installer: A firm with three (3) years of successful experience with installation of copper roofing of type and scope equivalent to Work of this Section. Submit qualifications. 1.6 APPLICABLE PUBLICATIONS: A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only: B. ASTM International (ASTM): B32-08(R2014)...Solder Metal B370-12...Copper Sheet and Strip for Building Construction D1970/D1970M-14...Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection D226/D226M-09...Asphalt-Saturated Organic Felt Used In Roofing and Waterproofing D227-03...Coal-Tar-Saturated Organic Felt Used in Roofing and Waterproofing D2822/D2822M-05(R2011)..Asphalt Roofing Cement F1667-13...Driven Fasteners: Nails, Spikes and Staples E1980-11...Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surfaces C. Copper Development Association Inc. (CDA): A4050...Copper in Architecture Handbook D. Sheet Metal and Air Conditioning Contractors National Association (SMACNA): Architectural Sheet Metal Manual (Seventh Edition - 2012) PART 2 - PRODUCTS SPEC WRITER NOTE: Make material requirements agree with applicable requirements specified in the referenced Applicable Publications. Update and specify only that which applies to the project. 07 61 16-2

2.1 SHEET COPPER: A. ASTM B370, temper H00, cold-rolled (Hard); minimum 4.9 kg per square meter (16 oz. per square foot). B. Natural weathering mill finished copper. No applied finish. //C. Recycled Content of Steel Products: Post consumer content plus onehalf of preconsumer content not less than // 30 // // // percent. // //D. Solar Reflectance Index: Not less than // 78 // // 29 // when calculated according to ASTM E1980. // 2.2 BATTENS: A. Copper Batten Caps: 4.9 kg per square meter (16 oz. per square foot). B. Wood Batten Strips: Fabricated to size indicated from lumber complying with requirements of 06 10 00, ROUGH CARPENTRY and preservative treated by pressure process using a chemical solution that is non-hygroscopic and non-corrosive to type of copper roofing. 2.3 FLASHING CEMENT: A. ASTM D2822/D2822M, Type I. 2.4 SOLDER: A. Copper solder conforming to ASTM B32. Provide muriatic acid flux neutralized with zinc or approved brand of soldering flux as required for use with metals to be soldered. 2.5 BITUMINOUS COATING: A. Provide cold-applied inert-type noncorrosive compound bituminous coating, nominally free of sulfur components and other deleterious impurities. 2.6 SEALANT: A. Provide sealant in accordance with CDA A4050 and manufacturer s recommendations. Submit descriptive information. 2.7 NAILS: A. ASTM F1667, copper slating nails with large flat heads and needle points. B. Nails of sufficient length to penetrate nailer at least 22 mm (7/8-inch). 2.8 RIVETS: A. Copper or copper alloy not less than 3 mm (1/8-inch) diameter with solid brass mandrels. Provide solid copper rivet (tinner s rivets) where structural integrity of seam is required. 07 61 16-3

2.9 UNDERLAYMENTS: A. Felt Underlayment: No. 30 felt in compliance with ASTM D226/D226M, Type II. B. Self-Adhering Modified Bitumen Underlayment: 1. Self-adhering modified bitumen membrane underlayment material in compliance with ASTM D1970/D1970M, and suitable for use as underlayment for copper metal roofing. 2. Membrane resistant to cyclical elevated temperatures for extended period of time is to be used in high heat service conditions. 3. Membrane is to have integral non-tacking top surface of polyethylene film or other surface material to serve as separator between bituminous material and copper metal products. SPEC WRITER NOTE: Confirm vapor retarder requirements has been shown on the drawings when required for local climatic conditions. A self-adhering modified bitumen membrane underlayment can act as a vapor barrier. Delete this paragraph if not required. //C. Vapor Retarder: Laminated or reinforced, woven polyethylene or polypropylene, synthetic roofing underlayment; 0.254 mm (10 mil) minimum; bitumen free; slip resistant; suitable for high temperatures over 111 deg C (220 deg F); and complying with physical requirements of ASTM D226/D226M for Type I and Type II felts. Provide a compatible tape which has equal or better water vapor control characteristics than the vapor retarder material. // D. Slip Sheet: Slip sheet to be 0.24 kg per square meter (5 pounds per 100 square foot) rosin sized unsaturated building paper. PART 3 - EXECUTION 3.1 INSTALLATION: A. General Metal Fabrication: Shop-fabricate work to greatest extent possible. Comply with details, dimensions, profiles shown and with applicable requirements and recommendations of the CDA, the SMACNA Manual, and other recognized industry practices. Fabricate for waterproof and weather-resistant performance with expansion provisions for running work, sufficient to permanently prevent leakage, damage, or deterioration of the work. Form work to fit substrate. Comply with material manufacturer s instructions and recommendations for forming material. Form exposed copper work without excessive oil-canning, 07 61 16-4

buckling, and tool marks, true to line and levels indicated, with exposed edges folded back to form hems. B. Roofing surface: 1. Clean, dry, and debris free before application. 2. Remove protrusions from the deck area. 3. Verify substrate has no voids, damaged, or unsupported areas. 4. Repair voids or unacceptable area before installing membrane. SPEC WRITER NOTE: Most substrate conditions require underlayment and slip sheets. Provide either self-adhering sheet underlayment or felt underlayment. Delete below only upon recommendation of metal manufacturer for specific project condition. Review roof assembly with underlayment types to avoid creating double vapor barrier in the roof/insulation assembly. //C. Self-Adhering Sheet Underlayment: 1. Prime substrates with manufacturer s approved primer if required for proper installation of membrane over substrate. 2. Install self-adhering sheet underlayment; wrinkle free on roofing substrate. 3. Comply with low-temperature installation restrictions of manufacturer where applicable. 4. Install underlayment, lapped in a direction to shed water. 5. Lap sides not less than 89 mm (3-1/2 inches). 6. Lap ends not less than 152 mm (6 inches) staggered 610 mm (24 inches) between courses. 7. Center membrane at valleys, hips, and ridges. 8. Roll laps with roller. 9. Cover underlayment within time requirements recommended by the manufacturer. // //C. Roofing Felt Underlayment: 1. Install underlayment over solid substrates with horizontal overlaps and endlaps staggered. 2. Lay parallel to ridgeline with 63 mm (2-1/2 inch) sidelaps and 152 mm (6 inch) endlaps. 3. Start application at low point, working up deck laying plies in shingle fashion. 4. Fasten underlayment with copper roofing nails spaced on 305 mm (12 inch) centers maximum. // 07 61 16-5

SPEC WRITER NOTE: Delete this paragraph if vapor retarder is not required. //D. Install vapor retarder over the entire roof substrate support surface. Use tape to seal the edges of the sheets to the support surface, or to the sheet below. Sheet edges to be lapped not less than 152 mm (6 inches). Provide sufficient material to avoid inducing stresses in the sheets due to stretching or binding. All tears or punctures that are visible in the finished surface at any time during the construction process to be sealed with the tape. // SPEC WRITER NOTE: Slip sheets are required for installations. Slip sheets must be installed over vapor retarder when vapor retarder is specified. E. Slip Sheet: 1. Apply specified slip sheet at time of roof panel installation when underlayment is used that may be in direct contact with and adhere to or adversely impact the underside of roof panels, and as otherwise recommended by the roof panel manufacturer. 2. Paper slip sheets must be installed over the underlayment. Use adhesive for temporary anchorage, where possible, to minimize use of mechanical fasteners under copper roofing. 3. Lap joints 50 mm (2 inch) minimum. F. Form tapered wood batten 76 mm (3 inches) wide at top, 57 mm (2-1/4 inches) wide at bottom and 38 mm (1-1/2 inches) high unless otherwise indicated in construction documents. Secure battens to roof deck construction with lag bolts or wood screws having the heads recessed below the top of the batten. Space battens to suit width of pans. G. Fabricate: 1. Fabricate pans to create center to center standing and batten seam spacing as indicated on construction documents. 2. Lay sheets of copper formed into pans with sides turned up to top of batten and out 13 mm (1/2-inch) for locking to cover. 3. Form cross seams by forming folds on upper and lower ends. 4. Stagger cross seams. Slit cross seam at each corner to form a tab. G. Form cleats of 50 mm (2-inch) wide 450 g (16 ounce) copper. Place cleats at center of each cross seam and along battens at 305 mm (12 inches) on center. H. Eaves and Rakes: 07 61 16-6

1. At eaves and rakes which do not abut vertical surfaces, turn roofing sheets over edge of roof sheathing and hook 19 mm (3/4-inch) over a 560 g (20 ounce) cold rolled copper edge strip. 2. Form edge strip from 2438 to 3048 mm (8 to 10 foot) long pieces with ends butted together. 3. Secure edge strip to roof deck with nails 101 mm (4 inches) on center. 4. Do not face nail roofing. I. Cover batten with copper. Lock edges together with flanges of pans and mallet down against side of battens. J. Ridges and Hips: Provide copper covered battens similar to roof battens. K. Cover exposed ends of battens with copper caps locked in place. 3.2 JOINING: A. Solder seams where required to produce water tight joints. Remove flux after soldering is completed. B. Tin edges of copper required to be soldered with solder for a width of 38 mm (1-1/2 inches). C. Joints in copper up to 560 g (20 ounce) weight may be soldered. D. Make joints for copper over 560 g (20 ounces) weight by lapping, riveting, and soldering. Space rivets 76 mm (3 inches) on center in two (2) rows in a staggered position. 3.3 SEALING: A. Where dowels, fastening devices and similar items penetrate roofing, make penetrations watertight by means of sealing compound. Sealing compound is specified in Section 07 92 00, JOINT SEALANTS. - - - E N D - - - 07 61 16-7