Installation of Vacuklav 24-B. 1 General features. Figure 1

Similar documents
The Premium-Plus-Class Now even better. Up to 9 kg of instruments!

PROCLASS A plus in quality: Vacuklav +

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Ray s top tips: Things to consider when buying an Autoclave:

Operating Manual. MELAquick 12+

Operations Manual. For Research Use Only. PH: EM: WEB:

REVERSE OSMOSIS SYSTEM USER'S MANUAL. Excellent Product, Excellent Water! My PurePro X6

STERILIZATION DEVICES

Phoenix - Mixing System MIX08/20 Inline 20

Cliniklav 25. For highest quality in surgical applications MELAG. Evidence Based Sterilization

PRO. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram. Scanomat Architect Pack (2D/3D Files)

PRO. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram. Scanomat Architect Pack (2D/3D Files)

LUBRICATION PUMP Z2 CENTRAL LUBRICATION

User Manual. Vacuklav 40-B Vacuklav 44-B. Autoclave. Dear doctor!

Pre-installation Manual. Plate Processor 68/85 Thermal

Partnership. HSG Pre & Post Vacuum - Medium Size Mobile Autoclave. Economic Line

AUTOCLAVE SERIES VERSION 18 AND 23 CLASS B CYCLES EXPERIENCE AND INNOVATION SINCE 1948

User Manual. Vacuklav 23 B+ Vacuklav 31 B+ Autoclave. as of software version Dear doctor,

RO102 P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address RO102

AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH

S800-Direct Flow USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

Customer Responsibilities

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

Price list valid:

DRINKING WATER CONDITIONERS WATER PURIFIERS U.V. STERILIZERS REVERSE OSMOSIS GELPUR FILTER 113 GELPUR FILTER SI 113 GELPUR SL

PRODUCT DESCRIPTION PARAMETERS

ChungHo Dealer Technical Guide

Thank you for Being our Customer!

User Manual. MELAtronic 15 EN+ Autoclave. as of software version V4.07. Dear Dr.

MELAtronic 15 MELAtronic 17 MELAtronic 23

Aqualife Products (Australia) Pty Ltd Steam Sterilisor Water System

User Manual. Euroklav 23 VS+ Euroklav 29 VS+ as of software version Autoclave. Dear doctor,

Fast. Easy to use. Secure traceability.

Model No. BWTDWFK-TRIFLO.

STERIVAPHP. Original without compromises. protecting human health. new line steam sterilizers

Stack Parking Surface Mounted Stackers

INTRODUCTION. History RAYPA was founded by Mr. Ramón Espinar nd generation take over New makeover

Basic design of laboratory bioreactor

Automatic Tabletop Autoclaves

PRIMARY GRADE WATER L A B W A T E R. PURELAB TM Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

PCB Water Cleaning System

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations...

Demineralisation. PUROTAP expert. Installation Function Operation Service. Demineralised heating water.

USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM ET-PURE. Type of product. Date of purchase. Address

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

INSTALLATION & OPERATING INSTRUCTIONS

BTT : 1 autoclave bin

Technical Description

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

SPIRIT. Water purifier. Complete User Manual

WARNINGS AND PRECAUTIONS

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.

Aqua-Recycling-Control 80B Plus

MRI Chiller Installation Guidelines

User Manual. Vacuklav 41 B+ Vacuklav 43 B+ Autoclave. as of software version Dear Dr.

PRIMARY GRADE WATER. PURELAB Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

HRO-50 Water Purifier

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

EN STERILINE 9.5. Class B and S sterilisation systems in compliance with international standards

STERIVAP. Excellent Price High Quality Engineering. protecting human health. Large steam sterilizer for health care

>> OUR ALL-IN-ONE AUTOCLAVE <<

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

For Safe and Delicious Water

Compact. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram

ERS-106UV USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

SCO Series - Air Jacketed Units. SHEL LAB CO2 Incubators

Gerber M Series Site Requirements

SOPHISTICATED DESIGN REQUIREMENTS IN PLANT ENGINEERING FOR AN XLPE EXTRUDER FEEDING PLANT AS AN EXAMPLE

User Manual. Euroklav 23 VS+ Euroklav 29 VS+ as of software version Autoclave. Dear doctor,

LARGE CAPACITY PHARMACEUTICAL AUTOCLAVES

Preparation of Reagent Water

MRI Chiller Installation Guidelines

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

Sterilization & Infection Control Products

Boss Water Systems Australia Reverse Osmosis System Model 021-4P-GM

RO400 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM RO400. Type of product. Date of purchase. Address

Enewall Render Silo User Guide

RD01 WHAT S IN THE BOX INSTALLATION MANUAL

Advanced water purifier system operation manual and setup guide

RC400G FC400G RESIDUAL CHLORINE ANALYZER RC400G NON-REAGENT FREE CHLORINE ANALYZER FC400G RESIDUAL CHLORINE ANALYZER

SMF WATER SYSTEMS. (PIC/S July.2004) By Anand Kuptamatee Thai FDA Conference September 19-21, 2005

Water treatment in dialysis technology

UltraGas. Technical Data Output range 15 to 2000 kw. Condensing Gas Boiler /02-07/15 Subject to modifications

R442A (RS-50) Features and uses of the R442A (RS-50) Lubricants TECHNICAL DATA SHEET. Barcelona Girona Madrid Zaragoza

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

RS-106M-P USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

Chapter 2. TC 2020 R FMC compact installation conditions. Drawing number: EN Part number:

Ventum Series. The new Generation Wood Gasification Boilers. Europe s Fastest Selling Wood Gasification Boiler.

STERIVAP. Excellent Price Economic use of utilities. protecting human health. Steam sterilizer for health care

Steam Sterilizer. SA Series. for hospitals, CSSD and medical centers

HDG Turbotec. HDG Log wood boilers. Comfortable and safe. 340-litre fuel chamber. Log wood sizes up to 1-metre long

Sump Pump System OEM INSTALLATION MANUAL

INSTALLATION MANUAL RD01

AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd

! CAUTION: Read and follow these instructions.

VaVie Water Purifier

Transcription:

Installation of Vacuklav -B The new Europe-autoclave Vacuklav -B uses fractionated pre-vacuum (air removal by sub atmospheric pulsing before sterilization). A high vacuum is achieved using a water-ring pump, which is both very efficient and extremely robust in continual operation. These instructions contain important information about the installation of the Vacuklav -B. Please read them carefully. General features Rear view Front view 0 Side view Figure Safety valve Serial printer port (RS ) Sterile filter Main fuses - x A /" cooling water inlet 0 Power switch /" cooling water outlet Vacuum pump safety switch Feed-water intake, Swivel screw-fit for pipe x Sliding door lock Power lead -. metre Door (hinges on left) Adjustable front feet Display and operating panel Page of

Installation requirements Installation of Vacuklav -B Before setting up the Vacuklav -B you should make sure that the following requirements are met: Space requirements In order to ensure adequate ventilation, there should be at least cm clearance to the sides and above the autoclave (for dimensions see Figure ), with cm clearance at the rear for connections. Sufficient room must also be available either for the MELAG reservoir container for distilled or demineralised water (0 cm x cm x cm), for a MELAdem or MELAdem 0 water demineraliser, or e.g. for the original container provided by a supplier.. Horizontal surface: A plane, horizontal surface is required which is sufficiently stable to support the autoclave (unloaded weight kg).. Power supply The power supply should be 0 V, 0 Hz, and 00 VA, with a A fuse protection, optionally with a 0 ma circuit breaker. The power cable supplied is. m long. If the MELAprint printer is also used, then an additional power socket will be required.. Water supply Connecting the Vacuklav -B autoclave to the water supply is much the same as fitting up a domestic washing machine. Care should be taken to ensure that the installation is in accordance with the relevant standards on drinking water supply systems (e.g. EN ). Whereas in domestic settings there are few problems, the threat of water contamination in doctors' or dentists' surgeries is considerable, and requirements should be adhered to strictly. [Part of EN on the protection of the drinking water supply system specifies a safety combination of nonreturn valve and pipe air-release valve ).] Many buildings already have such fittings. Additional it is practical to use a tap with integrated non-return valve and pipe air-release valve. You should ensure that the Vacuklav -B meets industrial standards, we recommend one of the following options as shown in Figure : Option I : Option II : The installation of a water tap with integrated security combination (MELAG Art. No.: 0) on an available or newly installed water pipe (rated width DN, /") The installation of an additional stop cock with integrated security combination (MELAG Art. No.: 0) directly at a corner valve of an existing water supply (e.g. for a sink or wash basin) with 0 mm pipe For a flow rate of litre/min the flow pressure should be >. bar. The cooling water pipe supplied with the Vacuklav -B is metres long. You should consider installing a leak detector with water-stop valve (Figure -Figure MELAG Art.-No.: 00). ) The combination of non-return and pipe-air release valves is sufficient for the general use of the autoclave (sterilisation of noninfectious material, prior disinfection). For the use of the autoclave as a "waste steriliser" for the sterilisation of microbiologically contaminated materials, EN requires a funnel between the drinking water supply and the cooling water inlet. Page of

Installation of Vacuklav -B Rear view Vacuklav -B Option I Option II Water tap with non-return and pipe-air release valves MELAG-Art-No: 0 Additional stop cock with nonreturn valve and pipe-air release valve (for use with existing corner valve) MELAG-Art-No.: 0 0 mm cold water supply (to mixing battery) Cooling water supply pipe (DN ) existing corner valve Figure. Cooling water outlet An outlet is required for the cooling water - either a wastewater outlet in the wall (rating DN 0) or a connection to an existing trap (e.g. under a sink). Examples for the connections are shown on pages and. In order to reduce noise caused by outflowing water, MELAG supplies a special quiet double-chamber trap which can replace the existing one. MELAG also supplies a metre pipe to connect the autoclave to the wastewater outlet, which should be at least 0 cm lower than the Vacuklav. The connecting pipe should be free of twists and kinks, and have a constant gradient, without any points where water can collect. The supply with feed water (distilled or demineralised) If an autoclave has a closed-loop water system, impurities in the water regularly lead to damage. Therefore, the Vacuklav -B has a one-way system. It either draws on water from a reservoir (which staff refill at regular intervals, e.g. with distilled water from the MELAdest ), or, even easier, it draws water directly from the ME- LAdem or MELAdem 0 water demineraliser. The feed-water (for steam production) must at least comply with the requirements for purified water in accordance with VDE Code of Practice 00.. Indirect supply (see page, Figure ) The Vacuklav -B draws distilled or demineralised water as required from a MELAG container (or other container) along a m pipe. The container should not be more than. m below the autoclave. Of course, it can also be placed alongside the Vacuklav -B.. Direct supply (see page, Figure ) Connection of the ion exchanger MELAdem 0 with spray gun MELAjet The simplest option is when the MELAdem 0 is connected directly to the feed water inlet of the Vacuklav -B. The MELAjet is used to clean off instruments with purified water before sterilisation.. Direct supply (see page, Figure ) Connection of reverse osmosis system MELAdem. The MELAdem reverse osmosis demineraliser can be connected directly to the feed-water inlet of the Vacuklav. Before using other water-treatment systems, you should consult with your MELAG-dealer to ensure that the water quality is adequate. Page of

Fitted installation: Installation of Vacuklav -B If you wish to fit the Vacuklav -B under a working surface we can supply special information on request. Installation material: The following installation material is supplied: Cooling water supply hose (m) Cooling water outlet hose (m) Double-chamber trap Storage container with tube. metre long and suction filter (if installation as Figure ) Supply hose. metre long and connector (if installation as Figure or Figure ) The following articles can be ordered: Wall outlet with Y-junction MELAG Art.-No.: 0 Y-junction with non-return valve for use with an existing trap MELAG Art.-No.: 00 / water tap with security combination MELAG Art.-No.: 0 Additional stop cock with non-return valve and pipe-air release valve (to be attached to an existing corner valve) MELAG Art.-No.: 0 Leak detector with stop valve and sensor MELAG-Art.-No.: 00 Filter for MELAdem MELAG-Art.-No.: 0 Safety combination for EN MELAG-Art.-No.: 0 Installation examples. Example : Feed water from a storage container and outlet via a wall-mounted trap 0 Figure Vacuklav -B rear view Safety combination for EN Cooling water supply pipe Water outlet pipe DN Leak detector with stop valve and sensor (MELAG Art. No.: 00 - optional) Water tap - belongs to the house installation Feed-water supply line with filter MELAG container for distilled or demineralised water - 0x0x0 mm (depth x width x height) Y-junction with non-return valve (MELAG Art.-No.: 00) 0 Double-chamber trap (MELAG Art.-No.: - in the supply included) Wall outlet (NW 0 - belongs to the house installation) Power connection Feed-water inlet Cooling water outlet Cooling water inlet Page of

Installation of Vacuklav -B. Example : Feed water from the MELAdem 0 and outflow via a double-chamber trap Figure 0 MELAjet (MELAG Art.-No.: 000) optional MELAdem 0 Cooling water supply pipe Cooling water inlet and supply piece for MELAdem 0 (MELAG Art.-No. - in the supply included) Cooling water outlet Water outlet pipe DN Double-chamber trap (MELAG Art.-No.: - in the supply included) Demineralised water feed line Filter for MELAdem 0 Water tap - belongs to the house installation Leak detector with stop valve and sensor (MELAG Art. No.: 00 - optional) Demineralised water feed line - in the supply included Vacuklav -B rear view Safety combination for EN. Example : Feed water from the MELAdem and outlet via a double-chamber trap 0 Figure Vacuklav -B rear view Safety combination for EN /" Y-junction (MELAG-Art.-No.: 00 - in the supply included)cooling water inlet Cooling water supply pipe Cooling water inlet Water outlet pipe DN Power connection Additional demineralised water outlet Double-chamber trap (MELAG Art.-No.: - in the supply included) 0 Y-junction with non-return valve (MELAG Art.-No.: 00 - in the supply included) Waste outflow of MELAdem Reverse osmosis system MELAdem Demineralised water feed line Filter for MELAdem Water tap - belongs to the house installation Leak detector with stop valve and sensor (MELAG Art. No.: 00 - optional) Feed water intake IA_00-00_GB_B.doc Rev.: 0/0 Page of