Updating Solid Phase Extraction Methods: Tips and Tricks for Improving Existing and New SPE Methods using Method Development

Similar documents
CLEAN SCREEN FASt FILTER AND SHOOT UCT FORENSICS. CLEAN SCREEN FASt SPE COLUMNS

Time, min

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

Application Note. Abstract. Authors. Food Safety

Illicit Drug Analysis in Urine Using 2D LC-MS/MS for Forensic Toxicology

A Generic Approach to the Extraction of Multi-functional Drugs using Mixed-mode SPE with LC-MS/MS Analysis

Extraction of Vitamin B7 (Biotin) from Serum Using EVOLUTE

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

Increased Throughput in the Determination of PPCPs in Water Using Optimized MS Cycle Times in a High Sensitivity UHPLC-Triple Quadrupole System

High Speed, Ultra-High Sensitivity, and Robustness Needed for the Quantitation of Pharmaceuticals in Blood Plasma. Application Note. Authors.

EPA Method 540: Selected Organic Contaminants Using Agilent Plexa Cartridges and the Agilent 6460 Triple Quadrupole LC/MS

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

Standard Operation Procedure (SOP) for the Extraction and Instrument Analysis of Siloxanes from Cartridges

DETERMINATION OF ORGANIC PRIORITY POLLUTANTS AND EMERGING COMPOUNDS IN WASTEWATER BY MICRO SOLID PHASE EXTRACTION COUPLED TO GCMS

Supporting Information

Jonathan R. Beck and Charles T. Yang; Thermo Fisher Scientific, San Jose, CA

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Determination of Table 3 Compounds by LC/MS/MS Chemours Fluoroproducts Analytical Method Revision date: 4/26/2018

Chemicals Branch United Nations Environment Programme (UNEP) Division of Technology, Industry and Economics. Geneva

Introduction Ron Majors is a Senior Scientist at Agilent. Bill Champion is a chemist in Agilent s HPLC Columns tech support group.

Pesticide Analysis in Drinking Water with Disk Extraction and Large Volume Injection

EFFECTIVE SPE STRATEGIES FOR LC/MS DETERMINATION OF SUDAN DYES IN CHILI PRODUCTS

Quantitatitive Analysis of Phosphorothioate Oligonucleotide in Human Plasma Using LC-MS/MS with On-Line Extraction

ITSP Extraction of Cortisol from Plasma

APPLICATION NOTE. Abstract. Introduction

Protein Separation with ph Gradients Using Composite Buffer Systems Calculated by the Agilent Buffer Advisor Software

Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

METHOD TRANSLATION OF HJ FOR INTUVO

LC Application Note.

VALIDATION AND DETERMINATION OF GLYPHOSATE AND AMPA IN WATER

Automated Sample Preparation for the Monitoring of Pharmaceutical and Illicit Drugs by LC-MS/MS

Quantitative Analysis of pesticides including Phenoxy-acids in surface and drinking water matrices using UPLC-ON-LINE-SPE-MS/MS

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

UCT ENVIRO-CLEAN HL DVB

Nitrosamines Analysis in Drinking Water Using GC/MS/MS Meeting Equivalence to EPA Method 521

Strategies for Phospholipid Removal using Polymer-based SPE

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

Converting a Liquid-Liquid Extraction Method for Vitamin D to a 96-Well Plate Supported Liquid Extraction Format

Application Note. Abstract. Authors. Introduction. Environmental

Confirmation of THC in Oral Fluids Using High-Resolution 2-D GC/MS Application Note

Nonylphenols and Ethoxylates in Water by LC/MS/MS

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

LC/MS/MS Determination of PFOS and PFOA in Water and Soil Matrices

Thank you for joining us! Our Webinar will begin shortly Principles of SPE: Troubleshooting Techniques

Simple Run Table Entry Cuts Sample onto Column 2. Method Developers Calculator to Tools correctly set flows and restrictor size

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

UPLC with On-line-SPE Technology for the Analysis of Pesticides and Pharmaceuticals in Drinking Water

Analysis of the Massachusetts Cannabis Pesticides List Using the SCIEX QTRAP System

Analysis of Atrazine in Drinking Water at the ppb Level Using New Agilent Reversed Phase LC Columns. Application. Author. Abstract.

Rapid Determination of Drug Protein Binding Affinity using Solid Phase Microextraction

EVOLUTE ABN FOR EXTRACTION OF DRUGS FROM BIOLOGICAL FLUIDS

2.1 This procedure provides steps and conditions for the determination of Vapor Space Organic Compounds in ground waters, and industrial waste waters.

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Determination of 1,4-Dioxane in Drinking Water by Gas Chromatography/Mass Spectrometry (GC/MS) with Selected Ion Monitoring (SIM)

Corn Syrup Analysis E-1a- 1. ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Rapid Extraction of Therapeutic Oligonucleotides from Primary Tissues for LC/ MS Analysis Using Clarity OTX, an Oligonucleotide Extraction Cartridge

A Sub-picogram Quantification Method for Desmopressin in Plasma using the SCIEX Triple Quad 6500 System

The analysis of natural and synthetic estrogens at sub ppt levels in surface water, crude influent and final effluent waters

CHROMATOGRAPHY/MASS SPECTROMETRY

[ product solution ] Waters Oasis µ Elution PlateS. Patented Innovation. Elution volume as low as 25 μl. No evaporation and reconstitution

Determination of Pesticides in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes. Application Note. Author. Abstract.

Multi-Residue Pesticide Analysis in Ginseng Powder: Optimized Cleanup After QuEChERS Extraction for UPLC-MS/MS And GC-MS/MS Analysis

Determination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Atlantic HLB SPE Disks

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

Application Note. Abstract. Authors. Environmental

Experimental Procedure

Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD. Application. Author. Abstract. Instrument Operating Parameters.

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

QUICK-REFERENCE METHOD GUIDE

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

A Sub-picogram Quantification Method for Desmopressin in Plasma using the AB SCIEX Triple Quad 6500 System

Simple Techniques for Improving the Isolation of Synthetic Peptides Jo-Ann Jablonski Principal Scientist Waters Corporation

Analysis of Trace Organic Contaminants in Water by Direct Injection Using Agilent 6490 LC/MS/MS with Pos/Neg Switching

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

SPE in Disk Format. Experimental. Table 1 Comparison of Typical SPE Cartridge and Empore Disk

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

User s Guide for Extracting Oligo Therapeutics from Biological Samples

Using HRAM Survey Analysis Combined with Rapid MS2 Data to Develop a Fragmentation Based Detection Workflow for Structure ID Acquisition

Automated Solid Phase Extraction of PAH Compounds Utilizing the SPE-DEX 5000

One SLE to measure them all: Two-part elution for analysis of urinary HIAA, HVA and VMA Zlatuse D. Clark 1, Sung Baek 2, Elizabeth L.

Agilent Consumables Improve Performance with Shimadzu GC/MS

Tabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2

Method Development of a 2D LC-HRMS Extraction and Detection Method for Organophosphorus Flame Retardants in Environmental Water Samples

University of Missouri Metabolomics Center User s Guide

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE.

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016

On-Line. User s Guide SPE CARTRIDGES. for Rapid Cleanup and Extraction of Analytes

The Agilent Metabolomics Dynamic MRM Database and Method

Residue Analysis of Pesticides in Food

Agilent Prep LC Columns for Small Molecules and Biomolecules MAINTAIN RAPID, RELIABLE SEPARATIONS AS YOU SCALE-UP

DRUG DISCOVERY & 2 September 2010

Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP1 and DB-CLP2

Determination of Manganese in Brine ( 30% NaCl)

Extraction and Analysis of Neonicotinoid Pesticides using QuEChERS Approach

ANALYSIS OF MYCOTOXINS IN FOOD MATRICES

3 Empore. High Performance Extraction Disk Cartridges October Answers to Frequently Asked Questions. Product Description

Performance characteristics of the 1260 Infinity Quaternary LC system

Interlaboratory Validation Study for the Analysis of Nitrosamines in Drinking Water using GC-MS/MS

Transcription:

Updating Solid Phase Extraction Methods: Tips and Tricks for Improving Existing and New SPE Methods using Method Development Golnar Javadi Application Engineer Sample Preparation Products Spp-support@agilent.com 1

Today s Agenda Updating Existing SPE methods- Why? How to Approach SPE Method Development/Optimization? Example 1: Solid Phase Extraction of Phencyclidine (PCP) in Urine by Mixed Mode-Bond Elut Certify Example 2: Solid Phase Extraction of Opiates in Urine by Mixed Mode-Bond Elut Certify Summary Questions and Wrap Up 2

UPDATING EXISTING SPE METHODS- WHY? 3

The Need for Updating Existing SPE Methods Requirements for lower detection limits Improved linearity in the lower or upper concentration range and calibration range extension Limited sample volume To improve the method to get cleaner samples in order to protect the high end analytical instruments and columns from sample contamination 4

Bond Elut Certify Bond Elut Certify, Mixed Mode (nonpolar + SCX) Bond Elut Certify II, Mixed Mode (nonpolar + SAX) Certify Methods Manual 5

HOW TO APPROACH SPE METHOD DEVELOPMENT/OPTIMIZATION? 6

Solid Phase Extraction Sorbents Nonpolar Polar Cation exchange Anion exchange Mixed mode Specialty phases 7

Four Steps of Solid Phase Extraction 8

10 Bottle Optimization 9

EXAMPLE 1: SOLID PHASE EXTRACTION OF PCP IN URINE BY MIXED MODE BOND ELUT CERTIFY 10

Target compound: Phencyclidine (PCP) pka: 8.29 Log P: 4.69

PCP: Sample pre-treatment Spiked urine pre-treatment: - Spike 50 ul of ISTD and STD to 5 ml of urine to have concentration in urine of 100 and 50 ng/ml for PCP and PCP-D5, respectively - Add 2 ml of 100 mm KH 2 PO 4 (ph = 5.81) Blank urine pretreatment: - Add 100 ul of water to 5 ml of urine - Add 2 ml of 100 mm KH 2 PO 4 (ph = 5.81) STD sample preparation: - Spike 50 ul of ISTD and STD to 7 ml of ACN 12

PCP:SPE Protocol (BE Certify 130 mg, 3 ml, Part number 12102051)- investigation of wash and elution solvents Condition: 2 ml MeOH Equilibrate: 2 ml 100 mm KH 2 PO 4 Load: Wash 1: Wash 2: Wash 3: Elute1,2,3: 1 ml of pretreated urine sample (spiked, blank) 1 ml 5% acetic acid 1 ml MeoH 1 ml MeOH 3 ml ACN + 2% NH 4 OH (3X1 ml aliquots, collect each aliquot separately) Evaporate under nitrogen @ 35 C Reconstitute in 0.5 ml EtOAc and 0.5 ml of 10% MeOH for GC and LC samples, respectively For solvent STD sample, transfer 1 ml of STD mix in ACN to autosampler vials Evaporate Reconstitute in 0.5 ml EtOAc and 0.5 ml of 10% MeOH for GC and LC samples, respectively.

PCP: Effluents of load, wash and elution steps 14

PCP: Chromatograms by LC-MS/MS for all eluates collected during SPE 15

PCP: SPE Protocol- Investigating different elution solvents Take 6 cartridges Condition: 2 ml MeOH Equilibrate: 2 ml 100 mm KH 2 PO 4 Load: Wash 1: Wash 2: 1 ml of pretreated urine sample (spiked, blank) 1 ml 5% acetic acid 2 ml MeOH For each set of two cartridges use one of the following elution solvents. Use one cartridge for LCQQQ, another for GC-MS Elution 1: Elution 2: Elution 3: 2 ml DCM/IPA (78/20) + 2% /NH4OH -apply to first 2 cartridges 2 ml of MeOH + 2% NH4OH- apply to the next 2 cartridges 2 ml of ACN + 2% NH4OH- apply to the last 2 cartridges Evaporate under nitrogen @ 35 C Reconstitute in 0.5 ml EtOAc and 0.5 ml of 10% MeOH for GC and LC samples, respectively For solvent STD sample, transfer 1 ml of STD mix in ACN to autosampler vials Evaporate Reconstitute in 0.5 ml EtOAc and 0.5 ml of 10% MeOH for GC and LC samples, respectively.

PCP: Comparison of Different Elution Solvents Collected elution After evaporation Cartridges after elution In elution related pictures, from left to right, ACN + 2% NH 4 OH, MeOH + 2% NH 4 OH, DCM/IPA/NH 4 OH 78/20/2 (v/v)

PCP:LC-MS/MS Conditions Column: Pursuit XRs ULTRA DP 2.8 um, 2.0 X 50 mm Flow rate: 0.4 ml/min Gradient: Inj. Vol.: 10 ul Fullscan: 100 550 m/z (positive) Time (min) %B 0 10 1.5 90 2.5 90 2.6 10 5 10 MRM: Precursor Product MS2 Res Dwell Fragmentor Col Eng Polarity PCP-D5 249.2 96.1 Unit 50 97 37 Pos PCP-D5 249.2 86.1 Unit 50 97 9 Pos PCP 244.2 91.1 Unit 50 102 37 Pos PCP 244.2 86.1 Unit 50 102 9 pos

PCP: LC-MS/MS fullscan of blank urine Elution by ACN + 2% NH 4 OH Elution by DCM/IPA/NH 4 OH (78/20/2) Elution by MeOH + 2% NH 4 OH

Y-axis scale is fixed PCP: LC-MS/MS MRM PCP PCP-D5 Elution by ACN + 2% NH 4 OH Elution by DCM/IPA/NH 4 OH (78/20/2) Elution by MeOH + 2% NH 4 OH

PCP-Final SPE Method after optimization SPE: Bond Elut Certify, 130 mg, 3 ml, 50/pk (p/n: 12102051) Condition 1 ml MeOH Equilibrate 1 ml 100 mm KH2PO4 Load: 1 ml of pretreated urine sample (spiked, blank) Wash 1 1 ml 5% acetic acid Wash 2 2 ml MeOH Elute 2 ml ACN + 2% NH4OH Evaporate and reconstitute in 0.5 ml of 30% ACN + 0.1% FA (Positive pressure was used for each step.)

PCP: LC-MS/MS Method optimization- Injection volume and injection solvent 23

PCP: GC-MS Conditions Column: Agilent DB-5ms UI, 15 m, 0.25 mm, 0.25 um (p/n: 122-5512UI) Flow rate: 2.5 ml/min Inj. Vol.: 1 ul Inlet: S 10:1 (temp: 250 C) Oven temp: start from 140 C, ramp to 240 C @ 40 C/min, hold for 2.5 min, then to 285 C @ 40 C/min, hold for 0.3 min (6.425 min) Aux heater: MS source: MS quad: 150 C 250 C 230 C

PCP: Fullscan GC-MS chromatograms of blank urine prepared by Bond Elut Certify using different elution solvents 25

PCP: GC-MS Fullscan/SIM Fullscan SIM Elution by ACN + 2% NH 4 OH Elution by MeOH + 2% NH 4 OH Elution by DCM/IPA/NH 4 OH 78/20/2 (v/v) Y-axis scale is fixed.

PCP: Calibration curves for PCP in urine, 1-500 ng/ml LC-MS/MS and GC-MS 27

PCP: Summary of LC-MS/MS and GC-MS accuracy and precision data 28

EXAMPLE 2: SOLID PHASE EXTRACTION OF OPIATES IN URINE BY MIXED MODE- BOND ELUT CERTIFY 29

Opiates and metabolites Codeine, pka 8.2 Morphine, pka 8.2 Hydromorphone, pka 8.6 Norcodeine, pka 9.2 Hydrocodone, pka 8.6 Oxymorphone, pka 8.2

Opiates: Sample pre-treatment: acid hydrolysis with ph adjustment after hydrolysis

Opiates: double blank urine pre-treatment : acid hydrolysis with ph adjustment after hydrolysis Acid Hydrolysis double blank urine: Add 5 ml urine to a 20 ml vial. Add 1.5 ml H2O. Add 1 ml concentrated HCl. Transfer 0.75 ml of spiked urine to 2 ml vials. Heat at 100 C for 30 min. Cool down. Add 0.5 ml 100 mm KH2PO4. Adjust ph with 10 M KOH.

Opiates: SPE Protocol - investigation of wash and elution solvents 34

Opiates: Pictures from Washes and Elutions Wash1 1 ml H2O Wash2 1 ml acetate buffer Wash3 1 ml MeOH Wash4 1 ml MeOH Wash5 1 ml MeOH Elution1:1 ml ACN + 2% NH4OH Elution2:1 ml ACN + 2% NH4OH Elution3:1 ml ACN + 2% NH4OH Elution1:1 ml DCM/IPA+ 2% NH4OH Elution2:1 ml DCM/IPA + 2% NH4OH Elution3:1 ml DCM/IPA + 2% NH4OH *DCM/IPA/NH4OH = 78/20/2 Elution1:1 ml MeOH + 2% NH4OH Elution2:1 ml MeOH + 2% NH4OH Elution3:1 ml MeOH + 2% NH4OH

Opiates : SPE Method work- in- progress 36

Opiates: investigation of how to apply the elution solvent

Opiates: SPE Method - Elution Results 1/3 1 ml elution 2/3 1 ml elution 3/3 1 ml elution 1/2 2 ml elution 2/2 1 ml elution 1/1 3 ml elution Compounds still coming out after 2 ml of elution solvent Need stronger elution e.g. 5% NH4OH

Opiates SPE Method : work- in- progress elution solvent strength study 39

Opiates SPE Method: Elution Study Result 1 st elution 2 nd elution DCM/IPA/NH4OH:78/20/2 DCM/IPA/NH4OH:78/20/2 DCM/IPA/NH4OH:75/20/5 DCM/IPA/NH4OH:75/20/5 EtOAc/IPA/NH4OH:78/20/2 EtOAc/IPA/NH4OH:78/20/2 EtOAc/IPA/NH4OH:75/20/5 EtOAc/IPA/NH4OH:75/20/5 DCM vs. EtOAc In general, EtOAc had slightly lower elution performance. 2% vs 5% NH4OH Did not show overall performance different, but 2% NH4OH had 2 nd elution peaks 4 5 % of the 1 st elution peaks. So 5% NH4OH is chosen.

Opiates-Final SPE Method after optimization Condition 1 ml MeOH Equilibration 1 ml 100 mm KH2PO4 Load 1 ml of hydrolyzed urine sample (ph=6.0-6.5) Wash1 1 ml water Wash2 1 ml 100 mm acetate buffer Wash3 2 ml MeOH Elution 2mL DCM/IPA/NH4OH:75/20/5 Dry under nitrogen at 35C to dryness Reconstitute in 0.5 ml of 10% MPB. 41

Summary and Conclusions Systematic approach to method optimization can modify old methods to fit new requirements and different analytical techniques. Bond Elut Certify methods can be adjusted to be used with LC- MS/MS as well as GC-MS. The same Certify method can be used with both techniques. Bond Elut Certify is an ideal SPE product for analysis of basic drugs from biological samples with great linearity, LOD, accuracy, and precision. Many application notes are available in Certify Methods Manual. 42

Additional Resources and Application Support Bond Elut Certify Methods Manual: http://www.chem.agilent.com/library/brochures/bond%20elut%20certify%20methodsm anual.pdf Bond Elut Certify Video: http://www.chem.agilent.com/en-us/products- services/columns-sample-preparation/sample-preparation/solid-phase-extraction- (SPE)/Bond-Elut-Certify/Pages/certifyvideo.aspx Application note 5991-4695EN: http://www.chem.agilent.com/library/applications/5991-4695en.pdf Application note 5991-4575EN: http://www.chem.agilent.com/library/applications/5991-4575en.pdf Agilent Sample Preparation Products Technical Support Contact Information* Phone: 800-227-9770, Options 3, 3, 3 Email: spp-support@agilent.com * North America 43

Acknowledgements Agilent applications chemists, product managers, and technical support personnel who contributed to this presentation 44

Questions? 45

Thank You 46