STEEL STUD & TRACK SYSTEM HEIGHT TABLES

Similar documents
Lightweight and Stable

TN002 New Zealand Seismic Installation Guide

FIRE RATED EXPOSED GRID CEILING SYSTEM

EARTHQUAKE- PRONE BUILDINGS POLICY

SRP CEILING SYSTEMS HANDBOOK

GIP-TEK TM PLASTERBOARD PRODUCT GUIDE

DRYLINING PRODUCT RANGE

PLASTERBOARD PORTFOLIO A complete range for any application

steel framing installation guide Steel Stud Drywall Framing Systems

SYSTEMS+ STEEL STUD WALLS INNOVATIVE SYSTEMS SOLUTIONS USGBORAL.COM

ENDUROFRAME building system. The smart, simple solution to house framing

Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings. Boris Iskra Forest & Wood Products Australia

PLASTERBOARD WET AREA SYSTEMS MANUAL

Rondo steel stud. Framing Systems Installation Manual. revised: october 2008

Intertenancy Barrier Systems for Terrace Homes

USG Australasia DONN. ScrewFixTM. Suspension System

Internal walls. Creating perfect living spaces. Technical Advice Centre Tel:

Patent Application No :

Union County Vocational - Technical Schools Scotch Plains, New Jersey

BOXSPAN RESIDENTIAL SPAN TABLES

GIB FIRE RATED SYSTEMS. Product. Scope. Building Regulations. Appraisal No. 289 [2018] Logo. Appraisal No. 289 (2018) BRANZ Appraisals

BORAL PLASTERBOARD Build something great. Multistop. Multi-attribute plasterboard

Technical Supplement. Internal Fire and Acoustic Rated Floor Solution INTERIORS

GTEK TM SOUND GTEK TM IMPACT

SYSTEMS+ SPECIALTY SYSTEMS INNOVATIVE SYSTEMS SOLUTIONS USGBORAL.COM

USG BORAL BRACING SYSTEMS. Product. Scope. Building Regulations. Appraisal No. 899 [2015] Appraisal No. 899 (2015) Amended 24 November 2017

Rondo Walk About Trafficable Ceiling System

BGC PLASTERBOARD PRODUCT GUIDE DECEMBER/2010

GIB EZYBRACE SYSTEMS 2011

GIB FIRE RATED SYSTEMS. Product. Scope. Building Regulations. Fire Rated Systems Specification and Installation Manual GIB. Appraisal No.

BOSTIK MS SAFE FIX ADHESIVE. Product. Scope. Appraisal No. 662 [2016] Appraisal No. 662 (2016) This Appraisal replaces BRANZ Appraisal No. 662 (2009).

FASTLOCK SUSPENDED CEILING GRID ECOPLUS SYSTEMS. FasTLock SUSPENDED CEILING GRID. Stronger, more durable

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

DRYWALL GRID SUSPENSION SYSTEM NEW ZEALAND.

Controlled Environments. KS1100 CS Data Sheet. Controlled Environment Panels. Insulated Panels

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

Assessing external noise impacts for apartments

LIGHTWEIGHT AND ECONOMICAL

Introduction. 2 June 2005 Boral FireCLAD. System Details. Benefits

USG BORAL WET AREA SYSTEMS. Product. Scope. Building Regulations. Appraisal No. 955 (2017) BRANZ Appraisals

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

Manufacturing Systems

Plywood (untreated or H3 treated) must not be allowed to come in contact with soil.

GypWall AUDIO The ultimate sound insulating wall system

LIQUID NAILS HIGH STRENGTH CONSTRUCTION ADHESIVE. Product. Scope. Appraisal No. 325 [2016]

MANUFACTURING SOLUTIONS. A Complete Design Build Solution for Residential, Institutional, Commercial and Industrial Buildings.

steel stud drywall ceiling systems

National Construction Code Series (NCC 2012) Building Code of Australia (BCA)

CERTIFICATE OF CONFORMITY

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers)

The development of generic span tables for cold formed steel studs in residential and low-rise construction

How to modify a tested fire-rated wall to improve its STC sound rating, while maintaining its official fire-rated qualification

TWO STOREY MASONRY VENEER DESIGN SOLUTION - FIRTH 10 SERIES HOLLOW MASONRY, MANORSTONE

USG Drywall Grid. Suspension System

At last! Construction bracing made easy...

ImpacWall Elephant Brand

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 2: DuraGalPlus RHS as lintels (garage beams, window heads)

GIB Quiet Clip GIB CBI March Features and Benefits

Lintels and Beams Engineering basis

Gypframe profiles. Dimensional specifications

Gypframe profiles. Dimensional specifications

84 Symonds Street PO Box 5811 Wellesley Street Auckland 1141 New Zealand T: F:

Galintel Steel Lintels

UL Design System HW-D-1012 continued

BGC PLASTERBOARD PRODUCT GUIDE

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

Updated references to SEI/ASCE 7 to the 2016 edition once it is available.

INSTALLATION MANUAL NEW ZEALAND

A GUIDE TO WINDOW AND DOOR SELECTION

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

6/4/2013. Fire Resistance Considerations - Prof Andy Buchanan & Andrew Dunn. Building Regulations

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

rondo steel stud drywall framing system

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Cavity & Smoke Barriers, Parapet & Spandrel Walls

Steel frame Loadbearing steel framed systems

GypLyner UNIVERSAL Concealed grid ceiling lining system

Contents. 1. Description, Scope and Application. Section 1 Description, Scope and Application 3. Section 2 Limitations 3. Section 3 Installation 4

POLICY EARTHQUAKE PRONE DANGEROUS & INSANITARY BUILDINGS

EXPOSED GRID CEILING SYSTEMS INSTALLATION GUIDE

GypWall QUIET Acoustic separating wall system

Lintels and Beams: Engineering Basis

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

GypLyner IWL Independent wall lining system

ECOPLY BARRIER FOR STEEL. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

SECTION NON--STRUCTURAL METAL FRAMING

Steel Framing Systems

Platinum Suite The equilibrium of strength and design

rondo accessories CONTENTS:

Single frame acoustic separating wall system

SECTION GYPSUM BOARD ASSEMBLIES

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

MTSP MANUFACTURE AND SUPPLY OF INSULATED RAIL JOINTS

Code Compliance and Product Selection

Impact Damage Resistant Wall Systems. GYP511 January 2011

Roof Systems. Span Tables & Thermal Ratings. Custom Roof Panel

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 957 [2017] Appraisal No. 957 (2017) BRANZ Appraisals

Transcription:

STEEL STUD & TRACK SYSTEM HEIGHT TABLES AS/NZ1170 COMPLIANT www.usgboral.com 1 JUNE 2015

General Offices Apartments Hotels Retail Malls Hospitals Banks USG Boral drywall steel stud and track systems offer practical and economical solutions for screw fixing plasterboard to internal, non-load bearing partitions, fire and acoustic rated walls, stairwells, bulkheads and corridor ceilings. Dimensionally stable, they stay straight and true, saving on time, materials and labour. They are strong, yet lightweight, easy to handle and require few tools Showrooms Education Industrial Fire rated areas For fire protection and safety, USG Boral Steel Stud & Track System can provide a number of different Fire Resistant Ratings in combination with the appropriate plasterboard lining. Lightweight and Stable Standards and Building Codes USG Boral uses the following Standards in its manufacturing, testing and marketing policies for compliance with the Building Code of New Zealand AS/NZS 1397 - Steel Sheet and Strip AS1530.4 - Fire Resistance of Elements of Building Construction AS/NZS 4600 - Cold Formed Steel Structures Code AS/NZS 1170 - Structural Design Actions NZBC B1/VM1 - NZ Building Code Verification Method B1/VM1 Clause 2 NZBC B2 Durability - USG Drywall Steel Stud & Track system will have a minimum serviceable life of 15 years when installed in a dry, non-corrosive, interior installation ISO 9000 Quality Assurance USG Boral Interiors Building Pacific Ltd Products is an NZ is accredited an certified ISO ISO 9001 9001 2008-2008 manufacturer No. Licence QEC No. 5044 5044 by Telarc SAI Quality ISO 9001 2 1 JUNE 2015 STEEL STUD & TRACK

USERS GUIDE ADVANTAGES of USG Steel Stud For all areas requiring a smoothly finished, monolithic wall plane Flat or curved Fire Resistant Ratings Flexibility of configuration Dimensionally stable Impervious to rot, fungal and insect attack Corrosion resistant Won t warp, twist or bow Easily worked, few tools required Non-combustible New Zealand made for New Zealand conditions Contents System Components Page 4 Standards References 5 Project Information 6 Wind Speed Table Selectors 7 Wall Height Tables 8-15 Certification I, Ernest B Lapish, MICE C. Eng. (London); FIPENZ (Structural); CPEng; IntPE (NZ), herby certify that maximum height tables prepared for USG non-loadbearing steel stud and track systems, comply with the requirements of: AS/ NZS 1170 Structural Design Actions, AS/NZS 4600:2005 Cold Form Steel Structures Code, and the New Zealand Building Code Testing and Calculations Physical testing was conducted at the Civil Materials Laboratory, Department of Civil and Resource Engineering, University of Auckland. Structural engineers Lapish Enteprises Ltd were engaged to calculate from the test results the maximum allowable wall heights, summarized in the tables on pages 8-15, based on the criteria outlined in this brochure. Managing Director Lapish Enteprises Ltd USG Australasia STEEL STUD & TRACK 1 JUNE 2015 3

SYSTEM COMPONENTS USG Boral Steel Stud and Track systems are manufactured in New Zealand using New Zealand Steel, in a variety of industry standard depths, lengths and gauges to suit the majority of interior partition system requirements. (Options not specifically listed may be able to be manufactured subject to engineering data and minimum order quantities.) Stud 32mm Stud Depth X mm BMT 51 64 75 92 100 150 0.50 0.55 X 0.75 35mm Floor/Ceiling Track Track Depth X mm X BMT 51 64 75 92 100 150 30mm* 0.55 0.75 3000 (or 2500 #) mm long * 40mm leg for 150mm track # To order only Deflection Head Track Fire Track X Track Depth X mm BMT 51 64 75 92 100 150 50mm 0.75 1.15 3000 (or 2500 #) mm long # To order only Nogging Track Track Depth X mm X Centres 51 64 75 92 100 150 30mm 300 N/A # # # # # 400 N/A # # # # # 0.75 BMT 3600mm long 450 N/A # # # # # 600 N/A # # N/A Not available # To order only Features Six standard depths to cater for the majority of applications Knurled stud faces assist screw fixing by stopping slipping and damage to board. Knurling also gives a better bond when adhesive is used with screw fixing. 2700mm + Ø25mm coined service holes The USG branding ensures easy identification of genuine components for compliance 2400mm 300mm 1000mm 2000mm 2500mm 4 4 2008 1 JUNE 2015 STEEL STUD & TRACK

STANDARDS REFERENCE The following information is taken from the AS/NZS 1170, as a quick reference guideline to assist with the selection of correct tables to determine the most appropriate stud and track combination to comply with the requirements of AS/NZS 1170. Terrain Category AS/NZS 1170.2, 4.2.1 Category 3 Terrain with numerous closely spaced obstructions 3m to 5m high such as areas of suburban housing Category 4 Terrain with numerous large, high (10m to 30m high) and closely spaced obstructions such as large city centres and well-developed industrial complexes Building Importance Level AS/NZS 1170.0, Table 3.2 Type 2: Normal structures not covered by Types 3 and 4; eg: single family dwellings, car parking buildings Type 3: Structures that may contain people in crowds, or contents of high value to the community or pose risks to people in crowds. eg: Where more than 300 people can congregate in one area Day care facilities with a capacity greater than 150 Primary or secondary school facilities with a capacity greater than 250 Colleges or adult education facilities with a capacity greater than 500 Healthcare facilities with a capacity of 50 or more resident patients but not having surgery or emergency treatment facilities Airport terminals, principal railway stations with a capacity greater than 250 Correctional institutions Multi-occupancy residential, commercial (including shops), industrial, office and retail buildings designed to accommodate more than 5000 people and with a gross area greater than 10,000 m² Public assembly buildings, theatres and cinemas of greater than 1000 m² Emergency medical and other emergency facilities not designated as post-disaster Power generating facilities, water treatment and waste water treatment facilities and other public utilities not designated as post disaster Buildings and facilities not designated as post disaster containing hazardous materials capable of causing hazardous conditions that do not extend beyond the property boundaries Type 4: Structures with special post-disaster functions eg: Buildings and facilities designated as essential facilities Buildings and facilities with special post-disaster function Medical emergency or surgical facilities Emergency service facilities such as fire, police stations and emergency vehicle garages Utilities or emergency supplies or installations required as backup for buildings and facilities of Importance Level 4 Designated emergency shelters, designated emergency centres and ancillary facilities Buildings and facilities containing hazardous materials capable of causing hazardous conditions that extend beyond the property boundaries STEEL STUD & TRACK 1 JUNE 2015 5

PROJECT INFORMATION Information The following steps will guide you through to the correct height tables and provide a project summary. Step 1 Terrain Category Select the Terrain Category from descriptions on page 5, or from architectural specification. Terrain Category 3 Terrain Category 4 Step 2 Building Importance Level Step 3 Wind Region Select the Building Importance Level from descriptions on page 5, or from architectural specification. Type 2 Type 3 Type 4 Select the Wind Region from the map A6 A7 W 2 3 1 KEY TO LOCATIONS 1 - Tauranga 2 - Huntly 3 - Hamilton 4 - Upper Hutt 5 - Blenheim 5 4 Step 4 Site Wind Speed Establish the Site Wind Speed from the local Territorial Authority if not already provided Low - 32mps Medium - 37mps High - 44mps Very High - 50mps 6 6 1 JUNE 2015 STEEL STUD & TRACK

SITE WIND SPEEDS Select the project Site Wind Speed Table and from the information on page 6 opposite then go to the appropriate Wall Height page as indicated within the tables. Low Wind Speed - 32mps Pages 8-9 Terrain Category 3 Terrain Category 4 Building Importance Level Building Importance Level Type 2 Type 3 Type 4 Type 2 Type 3 Type 4 Wind Region A6 / A7 W N/A N/A N/A N/A N/A Medium Wind Speed - 37mps Pages 10-11 Terrain Category 3 Terrain Category 4 Building Importance Level Building Importance Level Type 2 Type 3 Type 4 Type 2 Type 3 Type 4 Wind Region A6 / A7 W N/A N/A N/A N/A N/A High Wind Speed - 44mps Pages 12-13 Terrain Category 3 Terrain Category 4 Building Importance Level Building Importance Level Type 2 Type 3 Type 4 Type 2 Type 3 Type 4 Wind Region A6 / A7 W Very High Wind Speed - 50mps Pages 14-15 Terrain Category 3 Terrain Category 4 Building Importance Level Building Importance Level Type 2 Type 3 Type 4 Type 2 Type 3 Type 4 Wind Region A6 / A7 N/A N/A N/A W N/A N/A N/A 2008 STEEL STUD & TRACK 1 JUNE 2015 7 7

WALL HEIGHT TABLES Both Sides Low Wind Speed design wind pressure - 32mps Thickness Maximum Wall Height (metres) Maximum Wall Height (metres) 2.4 2.7 3.0 3.3 3.6 4.0 64 x 0.50 @ 400 ctrs 51 x 0.50 @ 400 ctrs 64 x 0.55 @ 600 ctrs 64 x 0.55 @ 450 ctrs 75 x 0.55 @ 450 ctrs 4.5 5.0 5.5 6.0 6.5 7.0 75 x 0.55 @ 450 ctrs 100 x 0.75 @ 400 ctrs 100 x 0.75 @ 300 ctrs 100 x 0.75 @ 300 ctrs NOTES: Tables are based on standard plasterboard as a minimum. Specialist function boards (eg. Fire, acoustic etc) may be substituted Values are based on the same thickness boards each side. Increased thickness board on just one side or multiple layers may be substituted Stud depths and gauge are minimums. Deeper stud and/or thicker gauge may be substituted if required for other reasons Stud spacing is a maximum. Closer centres may be used if required for other reasons Other stud sizes and spacing not listed may be suitable contact USG for advice LOAD ON TRACK FIXINGS (kn) at 600mm centre fixing maximum Stud Height (metres) 2.4 2.7 3.0 3.3 3.6 4.0 4.5 5.0 5.5 6.0 6.5 7.0 kn 0.216 0.243 0.27 0.297 0.324 0.36 0.405 0.45 0.495 0.54 0.585 0.63 FASTENER TYPE AND QUANTITY FOR TRACK FIXINGS at 600mm centre fixing maximum (evenly space multiple fixings) Load (kn) 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Concrete Floor 3.8 x 32mm Ramset 2 2 2 2 2 2 2 Timber Floor or Joist M6 Dynabolt 1 1 1 1 1 1 2 2.5 x 22mm Ramset Pin (gas) 2 2 2 2 2 2 3 Type 17 12g x 40mm 1 1 1 1 1 2 2 Steel 10g-16 x waferhead screw 2 2 2 3 3 3 4 3.2mm Blind Rivet - Steel 2 2 3 4 4 N/A N/A 3.2mm Blind Rivet - Aluminium 2 3 3 4 N/A N/A N/A 8 1 JUNE 2015 STEEL STUD & TRACK

WALL HEIGHT TABLES One Side Only Low Wind Speed design wind pressure - 32mps Thickness 2.4 2.7 3.0 3.3 3.6 4.0 51 x 0.50 @ 400 ctrs 75 x 0.75 @ 450 ctrs 4.5 5.0 5.5 6.0 6.5 7.0 100 x 0.75 @ 600 ctrs 100 x 0.75 @ 600 ctrs 100 x 0.55 @ 450 ctrs 100 x 0.75 @ 300 ctrs 100 x 0.75 @ 300 ctrs NOTES: Tables are based on standard plasterboard as a minimum. Specialist function boards (eg. Fire, acoustic etc) may be substituted Values are based on the same thickness boards each side. Increased thickness board on just one side or multiple layers may be substituted Stud depths and gauge are minimums. Deeper stud and/or thicker gauge may be substituted if required for other reasons Stud spacing is a maximum. Closer centres may be used if required for other reasons Other stud sizes and spacing not listed may be suitable contact USG for advice Continuous Nogging Track The USG Continuous Nogging Track is designed to be used to give support to and prevent twisting of the steel stud, particularly during installation of the plasterboard linings, single sided linings, and for taller wall heights. It may also be required where lighter weight articles are anticipated to be hung on the wall eg, picture, mirrors etc. It should be noted that if heavy articles are to be hung off the wall, this will require specific engineering design and correct installation prior to lining the wall. MINIMUM NUMBER OF CONTINUOUS NOGGING TRACKS Wall Height (metres) 3.0 3.3 3.6 4.0 4.5 5.0 5.5 6.0 6.5 7.0-8.0 Both Sides 0 0 0 0 1 1 1 1 1 1 One Side 1 2 2 2 2 2 2 2 3 3 Nogging Track Positioning Position equally spaced over the height of the wall. For deflection head track walls unlined or lined one side only, secure an extra nogging track 100mm on centre below the head track 2008 STEEL STUD & TRACK 1 JUNE 2015 9 9

WALL HEIGHT TABLES Both Sides Medium Wind Speed design wind pressure - 37mps Thickness 2.4 2.7 3.0 3.3 3.6 4.0 64 x 0.50 @ 400 ctrs 51 x 0.50 @ 400 ctrs 64 x 0.75 @ 450 ctrs 64 x 0.75 @ 450 ctrs 4.5 5.0 5.5 6.0 6.5 7.0 75 x 0.55 @ 450 ctrs 75 x 0.75 @ 400 ctrs 75 x 0.75 @ 450 ctrs 92 x 0.55 boxed @ 450 ctrs 92 x 0.55 boxed @ 400 ctrs 92 x 0.55 boxed@ 400 ctrs 92 x 0.55 boxed @ 450 ctrs 92 x 0.55 boxed @ 300 ctrs 92 x 0.55 boxed @ 300 ctrs 100 x 0.55 boxed @ 400 ctrs NOTES: Tables are based on standard plasterboard as a minimum. Specialist function boards (eg. Fire, acoustic etc) may be substituted Values are based on the same thickness boards each side. Increased thickness board on just one side or multiple layers may be substituted Stud depths and gauge are minimums. Deeper stud and/or thicker gauge may be substituted if required for other reasons Stud spacing is a maximum. Closer centres may be used if required for other reasons Other stud sizes and spacing not listed may be suitable contact USG for advice LOAD ON TRACK FIXINGS (kn) at 600mm centre fixing maximum Stud Height (metres) 2.4 2.7 3.0 3.3 3.6 4.0 4.5 5.0 5.5 6.0 6.5 7.0 kn 0.288 0.324 0.36 0.396 0.432 0.48 0.54 0.60 0.66 0.72 0.78 0.84 FASTENER TYPE AND QUANTITY FOR TRACK FIXINGS at 600mm centre fixing maximum (evenly space multiple fixings) Load (kn) 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Concrete Floor 3.8 x 32mm Ramset 2 2 2 2 2 2 2 Timber Floor or Joist M6 Dynabolt 1 1 1 1 1 1 2 2.5 x 22mm Ramset Pin (gas) 2 2 2 2 2 2 3 Type 17 12g x 40mm 1 1 1 1 1 2 2 Steel 10g-16 x waferhead screw 2 2 2 3 3 3 4 3.2mm Blind Rivet - Steel 2 2 3 4 4 N/A N/A 3.2mm Blind Rivet - Aluminium 2 3 3 4 N/A N/A N/A 10 10 2008 1 JUNE 2015 STEEL STUD & TRACK

WALL HEIGHT TABLES One Side Only Medium Wind Speed design wind pressure - 37mps Thickness 2.4 2.7 3.0 3.3 3.6 4.0 75 x 0.55 @ 450 ctrs 75 x 0.75 @ 450 ctrs 4.5 5.0 5.5 6.0 6.5 7.0 100 x 0.75 @ 600 ctrs 92 x 0.55 boxed @ 450 ctrs 100 x 0.75 @ 450 ctrs 150 x 0.75 @ 450 ctrs 100 x 0.75 @ 600 ctrs 92 x 0.55 boxed @ 450 ctrs 100 x 0.55 boxed @ 600 ctrs 100 x 0.75 @ 300 ctrs 150 x 0.75 @ 450 ctrs 100 x 0.55 @ 450 ctrs 92 x 0.55 boxed @ 450 ctrs 92 x 0.55 boxed @ 400 ctrs 100 x 0.75 @ 300 ctrs 100x 0.55 boxed @ 300 ctrs 150 x 0.75 @ 450 ctrs NOTES: Tables are based on standard plasterboard as a minimum. Specialist function boards (eg. Fire, acoustic etc) may be substituted Values are based on the same thickness boards each side. Increased thickness board on just one side or multiple layers may be substituted Stud depths and gauge are minimums. Deeper stud and/or thicker gauge may be substituted if required for other reasons Stud spacing is a maximum. Closer centres may be used if required for other reasons Other stud sizes and spacing not listed may be suitable contact USG for advice Continuous Nogging Track The USG Continuous Nogging Track is designed to be used to give support to and prevent twisting of the steel stud, particularly during installation of the plasterboard linings, single sided linings, and for taller wall heights. It may also be required where lighter weight articles are anticipated to be hung on the wall eg, picture, mirrors etc. It should be noted that if heavy articles are to be hung off the wall, this will require specific engineering design and correct installation prior to lining the wall. MINIMUM NUMBER OF CONTINUOUS NOGGING TRACKS Wall Height (metres) 3.0 3.3 3.6 4.0 4.5 5.0 5.5 6.0 6.5 7.0-8.0 Both Sides 0 0 0 0 1 1 1 1 1 1 One Side 1 2 2 2 2 2 2 2 3 3 Nogging Track Positioning Position equally spaced over the height of the wall. For deflection head track walls unlined or lined one side only, secure an extra nogging track 100mm on centre below the head track STEEL STUD & TRACK 1 JUNE 2015 11 11

WALL HEIGHT TABLES High Wind Speed design wind pressure - 44mps Thickness 2.4 2.7 3.0 3.3 3.6 4.0 64 x 0.50 @ 400 ctrs 51 x 0.50 @ 400 ctrs 75 x 0.55 @ 450 ctrs 75 x 0.55 @ 400 ctrs 4.5 5.0 5.5 6.0 6.5 7.0 75 x 0.75 @ 300 ctrs 92 x 0.55 boxed @ 400 ctrs 92 x 0.55 boxed @ 400 ctrs 100 x 0.75 @ 400 ctrs 92 x 0.55 boxed @ 300 ctrs 150 x 0.75 @ 450 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 450 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 450 ctrs 150 x 0.75 @ 300 ctrs NOTES: Tables are based on standard plasterboard as a minimum. Specialist function boards (eg. Fire, acoustic etc) may be substituted Values are based on the same thickness boards each side. Increased thickness board on just one side or multiple layers may be substituted Stud depths and gauge are minimums. Deeper stud and/or thicker gauge may be substituted if required for other reasons Stud spacing is a maximum. Closer centres may be used if required for other reasons Other stud sizes and spacing not listed may be suitable contact USG for advice LOAD ON TRACK FIXINGS (kn) at 600mm centre fixing maximum Stud Height (metres) 2.4 2.7 3.0 3.3 3.6 4.0 4.5 5.0 5.5 6.0 6.5 7.0 kn 0.432 0.486 0.54 0.594 0.648 0.72 0.81 0.90 0.99 1.08 1.17 1.26 FASTENER TYPE AND QUANTITY FOR TRACK FIXINGS at 600mm centre fixing maximum (evenly space multiple fixings) Load (kn) 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Concrete Floor 3.8 x 32mm Ramset 2 2 2 2 2 2 2 Timber Floor or Joist M6 Dynabolt 1 1 1 1 1 1 2 2.5 x 22mm Ramset Pin (gas) 2 2 2 2 2 2 3 Type 17 12g x 40mm 1 1 1 1 1 2 2 Steel 10g-16 x waferhead screw 2 2 2 3 3 3 4 3.2mm Blind Rivet - Steel 2 2 3 4 4 N/A N/A 3.2mm Blind Rivet - Aluminium 2 3 3 4 N/A N/A N/A 12 1 JUNE 2015 STEEL STUD & TRACK

WALL HEIGHT TABLES One Side Only High Wind Speed design wind pressure - 44mps Thickness 2.4 2.7 3.0 3.3 3.6 4.0 51 x 0.50 @ 400 ctrs 75 x 0.55 @ 450 ctrs 92 x 0.55 @ 400 ctrs 92 x 0.55 @ 400 ctrs 92 x 0.55 @ 400 ctrs 4.5 5.0 5.5 6.0 6.5 7.0 92 x 0.55 boxed @ 400 ctrs 92 x 0.55 boxed @ 400 ctrs 92 x 0.55 boxed @ 300 ctrs 92 x 0.55 boxed @ 300 ctrs 92 x 0.55 boxed @ 400 ctrs 150 x 0.75 @ 400 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 400 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 400 ctrs 150 x 0.75 @ 300 ctrs NOTES: Tables are based on standard plasterboard as a minimum. Specialist function boards (eg. Fire, acoustic etc) may be substituted Values are based on the same thickness boards each side. Increased thickness board on just one side or multiple layers may be substituted Stud depths and gauge are minimums. Deeper stud and/or thicker gauge may be substituted if required for other reasons Stud spacing is a maximum. Closer centres may be used if required for other reasons Other stud sizes and spacing not listed may be suitable contact USG for advice Continuous Nogging Track The USG Continuous Nogging Track is designed to be used to give support to and prevent twisting of the steel stud, particularly during installation of the plasterboard linings, single sided linings, and for taller wall heights. It may also be required where lighter weight articles are anticipated to be hung on the wall eg, picture, mirrors etc. It should be noted that if heavy articles are to be hung off the wall, this will require specific engineering design and correct installation prior to lining the wall. MINIMUM NUMBER OF CONTINUOUS NOGGING TRACKS Wall Height (metres) 3.0 3.3 3.6 4.0 4.5 5.0 5.5 6.0 6.5 7.0-8.0 Both Sides 0 0 0 0 1 1 1 1 1 1 One Side 2 2 2 2 3 3 3 4 4 N/A Nogging Track Positioning Position equally spaced over the height of the wall. For deflection head track walls unlined or lined one side only, secure an extra nogging track 100mm on centre below the head track 2008 STEEL STUD & TRACK 1 JUNE 2015 13 13

WALL HEIGHT TABLES Both Sides Very High Wind Speed design wind pressure - 50mps Thickness 2.4 2.7 3.0 3.3 3.6 4.0 64 x 0.55 @ 600 ctrs 64 x 0.50 @ 400 ctrs 75 x 0.55 @ 400 ctrs 4.5 5.0 5.5 6.0 6.5 7.0 75 x 0.75 @ 300 ctrs 92 x 0.55 boxed @ 400 ctrs 92 x 0.55 boxed @ 450 ctrs 100 x 0.75 @ 400 ctrs 92 x 0.55 boxed @ 300 ctrs 150 x 0.75 @ 450 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 450 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 450 ctrs 150 x 0.75 @ 300 ctrs NOTES: Tables are based on standard plasterboard as a minimum. Specialist function boards (eg. Fire, acoustic etc) may be substituted Values are based on the same thickness boards each side. Increased thickness board on just one side or multiple layers may be substituted Stud depths and gauge are minimums. Deeper stud and/or thicker gauge may be substituted if required for other reasons Stud spacing is a maximum. Closer centres may be used if required for other reasons Other stud sizes and spacing not listed may be suitable contact USG for advice LOAD ON TRACK FIXINGS (kn) at 600mm centre fixing maximum Stud Height (metres) 2.4 2.7 3.0 3.3 3.6 4.0 4.5 5.0 5.5 6.0 6.5 7.0 kn 0.504 0.567 0.63 0.693 0.756 0.84 0.945 1.05 1.155 1.26 1.365 1.47 FASTENER TYPE AND QUANTITY FOR TRACK FIXINGS at 600mm centre fixing maximum (evenly space multiple fixings) Load (kn) 0.4 0.6 0.8 1.0 1.2 1.4 1.6 Concrete Floor 3.8 x 32mm Ramset 2 2 2 2 2 2 2 Timber Floor or Joist M6 Dynabolt 1 1 1 1 1 1 2 2.5 x 22mm Ramset Pin (gas) 2 2 2 2 2 2 3 Type 17 12g x 40mm 1 1 1 1 1 2 2 Steel 10g-16 x waferhead screw 2 2 2 3 3 3 4 3.2mm Blind Rivet - Steel 2 2 3 4 4 N/A N/A 3.2mm Blind Rivet - Aluminium 2 3 3 4 N/A N/A N/A 14 1 JUNE 2015 STEEL STUD & TRACK

WALL HEIGHT TABLES One Side Only Very High Wind Speed design wind pressure - 50mps Thickness 2.4 2.7 3.0 3.3 3.6 4.0 75 x 0.55 @ 450 ctrs 92 x 0.55 @ 400 ctrs 92 x 0.55 @ 400 ctrs 100 x 0.55 @ 450 ctrs 4.5 5.0 5.5 6.0 6.5 7.0 92 x 0.55 boxed @ 450 ctrs 92 x 0.55 boxed @ 450 ctrs 92 x 0.55 boxed @ 300 ctrs 100 x 0.55 boxed @ 450ctrs 92 x 0.55 boxed @ 300 ctrs 92x 0.55 boxed @ 400 ctrs 100 x 0.55 boxed @ 300ctrs 100 x 0.55 boxed @ 300ctrs 150 x 0.75 @ 400 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 400 ctrs 150 x 0.75 @ 300 ctrs 150 x 0.75 @ 450 ctrs 150 x 0.75 @ 300 ctrs NOTES: Tables are based on standard plasterboard as a minimum. Specialist function boards (eg. Fire, acoustic etc) may be substituted Values are based on the same thickness boards each side. Increased thickness board on just one side or multiple layers may be substituted Stud depths and gauge are minimums. Deeper stud and/or thicker gauge may be substituted if required for other reasons Stud spacing is a maximum. Closer centres may be used if required for other reasons Other stud sizes and spacing not listed may be suitable contact USG for advice Continuous Nogging Track The USG Continuous Nogging Track is designed to be used to give support to and prevent twisting of the steel stud, particularly during installation of the plasterboard linings, single sided linings, and for taller wall heights. It may also be required where lighter weight articles are anticipated to be hung on the wall eg, picture, mirrors etc. It should be noted that if heavy articles are to be hung off the wall, this will require specific engineering design and correct installation prior to lining the wall. MINIMUM NUMBER OF CONTINUOUS NOGGING TRACKS Wall Height (metres) 3.0 3.3 3.6 4.0 4.5 5.0 5.5 6.0 6.5 7.0-8.0 Both Sides 0 0 0 0 1 1 1 1 1 1 One Side 2 2 2 3 3 3 4 4 5 N/A Nogging Track Positioning Position equally spaced over the height of the wall. For deflection head track walls unlined or lined one side only, secure an extra nogging track 100mm on centre below the head track STEEL STUD & TRACK 1 JUNE 2015 15

To request literature, samples, a visit from a USG Boral Ceilings specialist, or for all technical questions, call your nearest USG Boral office below. www.usgboral.com USG Boral, the USG Boral Logo and usgboral.com, are registered trade marks of USG Boral Australian Gypsum Ltd in Australia, other countries, or both. If these and other USG Boral trade marks are marked on their first appearance in this information with trade mark symbols ( or ), these symbols indicate Australian registered or common law trade marks owned by USG Boral and others at the time this information was published. Such trade marks may also be registered or common law marks in other countries. Copyright USG Boral Building Products NZ 2015 This technical information is intended to provide general information on products and should not be a substitute for professional building advice. We recommend you use a qualified person to install USG Boral. Illustrations in this guide are only representative of USG Boral products and the appearance and effects that may be achieved by their use. To ensure the information you are using is current, USG Boral recommends you review the latest building information available on the USG Boral website. For further information contact TecASSIST or your nearest USG Boral Sales Office. 0800 USGBORAL www.usgboral.com