COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

Mississippi Home Inspector Regulatory Board Standards of Practice and Code of Ethics

N.J.A.C. 13: NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2015 by the New Jersey Office of Administrative Law

a) For the purposes of this Section, the terms listed below shall mean:

CONNECTICUT HOME INSPECTION LICENSING BOARD Department of Consumer Protection 165 Capitol Avenue, Hartford, CT 06106

9) Home Inspection: As defined in Section 1-10 of the Act.

TITLE 68: PROFESSIONS AND OCCUPATIONS CHAPTER VIII: DEPARTMENT OF FINANCIAL AND PROFESSIONAL REGULATION

ASHI STANDARD OF PRACTICE FOR HOME INSPECTIONS

Section Standards of Practice. a) The following are terms commonly used in the writing of home inspection reports.

Page 3 of 12. Inspected Describe. Explained. Health & Safety. Maj. Def. Examiner Notes STRUCTURE N/A. Financial Impact. Impact.

ARIZONA. American Society of Home Inspectors. Arizona Chapter. Adopted by AZ ASHI Effective January 1, and

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

HOME INSPECTOR MINIMUM STANDARDS OF PRACTICE. A. In this chapter, the following terms have the meaning indicated.

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011

Alabama Home Inspections

2002 CAPHI (BC) Townhouse Standards of Practice Page 1

,Home Inspection Report

The following is the Standards of Practice (SOP) for Home Inspectors required by the state of Florida.

Inspection Report. Property Address:

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

Inspection Report. 1 of 8

1234 Main St. Buyer Name. Table of Contents

2002 CAPHI (BC) Apartment Style Condominium Standards of Practice Page 1

Title 09 DEPARTMENT OF LABOR, LICENSING, AND REGULATION

SOUTH CAROLINA HOME INSPECTOR STANDARDS OF PRACTICE

Canadian Association Of Home & Property Inspectors

The Home Doctor, Inc.

1234 Main St Denver CO 80210

Building Inspection Report

REPORT CHECKLIST SUPPLEMENT

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012

Home Inspection Report

Canadian Association Of Home & Property Inspectors

SC Standards Of Practice for Home Inspectors

Canadian Association Of Home & Property Inspectors

All Pro Home Inspection. Home Report South Your Town

All Pro Home Inspection. Home Report North Your Town

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017

State of Mississippi

Canadian Association Of Home & Property Inspectors

Home Condition Checklist

Property Inspection Report

component was performing its intended function; installation and condition were appropriate for age and use.

UP AND UP HOME INSPECTIONS

Property Inspection Checklist

Madison's Home Inspections

Pre-Listing Home Inspection Checklist

Inspection Report. Baruch Weiner. Property Address: 123 Main St. Monsey NY Capital Property Inspection Corp.

Summary. Inspect It Like A Girl. P.O. Box 2283 Madison, MS Customer Happy Home. Address 123 Happy Home Road Jackson MS 39157

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

THE STANDARD OF PRACTICE FOR HOME INSPECTIONS AND THE CODE OF ETHICS FOR THE HOME INSPECTION PROFESSION

Standards of Practice for Building Inspections, recognized by the OACIQ

Total Home Inspection Checklist

InterNACHI Home Inspection Report Checklist

3D Home Improvement and Inspection Services, Inc

Bill Ostoyic Building Inspection Report XXXXXXX XXXXX XXXXX, Fl. Licensed and Insured

6954 Lakeside Dr. Property Inspection Report. - Provided by First Class Property Inspections, LLC -

BEST HOME INSPECTIONS

Inspection Report. Provided by: Cummins Services LLC. Inspector: Bill Cummins. Phone:

Hogue Home Inspections

FAIRA TRANSPARENCY REPORTS S Proctor St, Tacoma, WA March 29 th, 2017

WEST MICHIGAN HOME INSPECTORS LLC 3134 Chamberlain SE Grand Rapids MI

Report Page 1 of 23 12/30/2013 Tri-City Home Inspections James Eddy ID:

Friendly Inspection Services

SUMMARY 1234 Main St.Loudon TN Buyer Name 08/28/2018 9:00AM

The Inspector. Property Inspection Report

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

A1-Inspections. Building Inspection Report. (Div of Canada Inc.) Inspection Date: Prepared For: Report Sample

FAIRA TRANSPARENCY REPORTS th Street Southeast, Puyallup, WA, June 1 st, 2017

FINEGAN INSPECTION SERVICES, INC.

A Summary of the Basic Duties of Maintenance, Repair and Replacement for CARRIAGE PARK CONDOMINIUM ASSOCIATION

Rental Inspection Checklist

TML Home Inspectors, Inc.

Inspect Hawaii. Property Inspection Report

Inspection Report. Virgina Smith. Property Address: 123 Anywhere Street. Foley Al Inspected Property. Precise Home Inspections LLC

Inspection Report. American Homebuyer. Property Address: 200 Pleasant Street. Hometown RI Hearthstone Home Inspection

J & M Solutions, LLC

Inspection Report. Mr. Frank Borey. Property Address: 9907 Summit Ave NE. Rockford MI Key Home Inspections, LLC.

HOME INSPECTORS CHAPTER


SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

Continuing Certificate of Occupancy Pre-Inspection Checklist

Friendly Inspection Services

Friendly Inspection Services

HOME INSPECTORS ASSOCIATION BC SCOPE OF INSPECTION 2016

New Hope Inspections, LLC Property Inspection Report

HARPER WOODS BUILDING DEPARTMENT PROCEDURES FOR OBTAINING CERTIFICATE OF OCCUPANCY

Property Condition Assessment

1. Definitions and Scope. Robert Young's Montreal Home Inspection Services Inc STANDARDS OF CARE. Table of Contents

Property Inspection Report

FAIRA TRANSPARENCY REPORTS

1623 Carol Street Downers Grove, Illinois Inspection Report for Property at: Private Home Inspection for:

Transcription:

Property Inspection Report HOUSE ADDRESS Report Prepared For: YOUR NAME HERE Report Prepared By: Sandra Mount Giant Jim Inspection Services PO Box 1346 Manteca, CA 95336 (800) 231-8517 (800) 836-0350 fax Report Number:

Page 2 of 20 GENERAL INFORMATION Inspection Address Street: ADDRESS City: Livermore State: California Zip: 94551 Inspection Details Inspection Date: May 22, 2013 Report Date: May 24, 2013 Building Occupied: yes occupied Construction Type Construction Style: residence is a two story Residence Type: single-family dwelling Building Details Date Built: 1993 Bedrooms: four Bathrooms: three Supporting Foundation: is built on a slab-on-grade Approximate Area: 2240 Sq. Ft. Client Information Name: YOUR NAME HERE Inspected By Name: Richard Hicks Company Information Company: Giant Jim Inspection Services Address: PO Box 1346 City: Manteca State: CA Zip: 95336 Phone: (800) 231-8517 FAX: (800) 836-0350 Email: giantjims@yahoo.com

Page 3 of 20 TABLE of CONTENTS GENERAL INFORMATION... 2 TABLE of CONTENTS... 3 SUMMARY OF DEFICIENCIES... 5 SECTION 1: Foundations and Under-floor Areas... 7 SECTION 2: Exteriors... 8 SECTION 3: Roof Coverings... 11 SECTION 4: Attic Areas and Roof Framing... 12 SECTION 5: Plumbing... 13 SECTION 6: Electrical Systems... 14 SECTION 7: Heating Systems... 15 SECTION 8: Central Air Conditioning... 16 SECTION 9: Fireplaces and Chimneys... 17 SECTION 10: Building Interior... 18 GENERAL LIMITATIONS AND EXCLUSIONS... 20

Page 4 of 20 CLASSIFICATIONS USED IN THIS REPORT Clients must have a clear understanding of the terms used in this report. The following conventions have been used to highlight or categorize issues encountered by the writer during the inspection. For your convenience, the following conventions have been used in this report. MAJOR CONCERN: a system or component, which is considered significantly deficient or is unsafe. Significant deficiencies need to be corrected and, except for some safety items, are likely to involve significant expense. SAFETY ISSUE: denotes a condition that is unsafe and in need of prompt attention. REPAIR: denotes a system or component which is missing or which needs corrective action to assure proper and reliable function. IMPROVE: denotes improvements, which are recommended but not required. MONITOR: denotes a system or component needing further investigation and/or monitoring in order to determine if repairs are necessary. DEFERRED COST: denotes items that have reached or are reaching their normal life expectancy or show indications that they may require repair or replacement anytime during the next five (5) years. FURTHER INSPECTION: Inaccessible areas at the time of original inspection. Please note that those observations listed under Discretionary Improvements are not essential repairs, but represent logical long-term improvements. We have numbered the items in this report using the following Section Identifiers (which can be found in the Table of Contents on page 2): 1. Foundation and Under-floor Areas 6. Electrical Systems 2. Exteriors 7. Heating Systems 3. Roof Coverings 8. Central Cooling Systems 4. Attic Areas and Roof Framing 9. Fireplaces and Chimneys 5. Plumbing 10. Building Interior This report is not a warranty and this firm does not warrant that this report will be accepted as written by all parties to the transaction. Clients are cautioned that trade professionals will not always agree with these assessments. Some may see an issue as more serious than described here, while others may consider an issue less serious or even non-existent. That is because these conventions are the writer s subjective assessment only, and are based on his or her own training and experiences. For that reason this firm recommends that clients always obtain estimates for repairs from their own contractor, not those chosen by a seller or a real estate agent, and be sure to obtain a second opinion concerning all costs and proposed repairs.

Page 5 of 20 SUMMARY OF DEFICIENCIES Note: This analysis is not meant to be technically exhaustive but rather to highlight areas where repairs are needed or areas of longterm future concern relating to maintenance and operation. This summary lists items taken from the main report that we feel need immediate attention or consideration. It is entirely the customer's decision whether or not to include additional items from the main report that they may have concerns about. Further, the Summary is not a substitute for reading and understanding the complete report. SECTION 2: Exteriors 1. MONITOR: This structure has a pressed-type siding installed. It is common for this type of material to swell and hold moisture. It is imperative for this siding to be kept sealed with a high-density paint and for all joints to be kept sealed and/or caulked. There is a high probability of hidden damage with this type of material. 2. REPAIR: There are one or more areas where the trim is damaged. Exterior trim is the most vulnerable to attack by rot, and it doesn t have to be very old. These areas left unattended can lead to further damage. We recommend contacting a competent carpenter for repairs. 3. REPAIR: Evidence of cracking in the patio slab was noted. We recommend sealing all cracks so water infiltration does not occur. 4. REPAIR: The fence is damaged. We recommend contacting a fencing contractor for repair. 5. REPAIR: Portions of the eaves are badly deteriorated and need to be replaced. I recommend immediate replacement by a competent carpenter. 6. IMPROVE: There are various plants and or bushes next to the exterior wall(s). Recommendation: Trim or prune all vegetation in such a way as to allow a minimum of six inches of clearance between the plant and the exterior wall. This is necessary in order to prevent damage to the exterior and to inhibit the ability of insects to migrate into the building structure. 7. FURTHER INSPECTION: Portions of the exterior were inaccessible due to a shed. Upon request and for an additional charge we will return to inspect these areas when they have been made accessible by others. We make no representation of inaccessible areas. 8. IMPROVE: The side garage door is weathered. We recommend repairing or replacing the side garage door. SECTION 3: Roof Coverings 1. IMPROVE: Trees or branches overhang the house. This condition, if allowed to continue, could result in damage to either the roof covering or the siding on the home. Recommendation: Trim branches to provide at least a six-inch separation between roof or wall and tree branches. 2. REPAIR: One or more of the tiles on the roof is not secured and slipped out of position. Recommendation: Repair as appropriate by a licensed roofing contractor. SECTION 5: Plumbing 1. REPAIR: The showerheads in the upstairs and downstairs baths are missing. Recommend repair as appropriate by a licensed plumbing contractor. SECTION 6: Electrical Systems 1. REPAIR: The main panel was inaccessible due to bushes. We recommend making the panel accessible and then have it re-inspected. 2. REPAIR: There are light fixtures loose/ missing with the wiring exposed in the attic. We recommend installing a new fixture.

Page 6 of 20 SECTION 7: Heating Systems 1. MONITOR: At the time of this inspection we started the furnace and it heated at normal working temperature. When we completed the test we turned off the furnace 2. MONITOR: At the time of this inspection the readings in the registers all were above 100 degrees at the registers. SECTION 8: Central Air Conditioning 1. MONITOR: At the time of this inspection the readings in the registers all were below 60 degrees at the registers. 2. MONITOR: At the time of this inspection we were able to start the air conditioning system and it cooled at the normal working temperature. At the end of the test we turned the unit off.. SECTION 10: Building Interior 1. IMPROVE: Small carpet stains are visible at random areas of the home. We recommend having the carpets cleaned. 2. SAFETY ISSUE: The shower door top rail in the downstairs bathroom is not connected by a safety screw to the side rails. The safety screw holds the top rail to the side rails so the doors and top rail do not come off the side rail causing injuries. We recommend installing a safety screw. 3. REPAIR: The hood vent/micro vent does not work. We recommend contacting an appliance repairman or just replacing the hood. 4. REPAIR: The pedestrian door between the garage and the house is incorrect because it is missing one of the following. A pedestrian door really should be a 20-minute fire-rated type, have tight-fitting gaskets, be fitted with a self-closing hinge and able to close and latch itself easily without binding. This ensures that the door won't be left open allowing vehicle exhaust, chemical fumes or smoke to enter the house. This door may not have needed to meet these requirements under local code at the time of original construction. Because these standards have been established in the interest of health and safety, I recommend having the door brought into full compliance with current standards. Another requirement for the entry door from the garage into the house is to be slightly elevated / higher than the garage floor surface. Many building codes require a step (or curb) between the house door and the garage floor. The step (min 4? recommended, but check your local code) prevents spilled gasoline vapors from entering the house and partially protects residents from carbon monoxide fumes. 5. REPAIR: The door handle on the side garage door is loose. We recommend repairing as necessary.

Page 7 of 20 SECTION 1: Foundations and Under-floor Areas In accordance with the ASHI standard of practice pertaining to Structural Systems, this report describes the foundation, floor, wall, ceiling and roof structures and the method used to inspect any accessible attics and under floor crawlspace areas. Inspectors are required to inspect and probe the structural components of the home, including the foundation and framing, where deterioration is suspected or where clear indications of possible deterioration exist. Basement Crawlspace Basement Crawlspace Type: Slab foundation Foundation Type: Concrete slab Foundation Material: Poured concrete Probing is not done when doing so will damage finished surfaces, when no visible deterioration exists and if doing so requires inspectors to be licensed pest control operators (PCO), unless the inspector involved is so licensed. Inspectors are NOT required to offer an opinion as to the structural adequacy of any structural systems or components or provide architectural services or an engineering or structural analysis of any kind.

Page 8 of 20 SECTION 2: Exteriors In accordance with the ASHI standard of practice pertaining to Exteriors, this report describes the exterior wall coverings and trim. Inspectors are required to inspect the exterior wall coverings, flashing, trim, all exterior doors, the stoops, steps porches and their associated railings, any attached decks and balconies and eaves, soffits and fascia accessible from ground level. Building Exterior Wall Surface Material: Stucco and Wood siding Wall Trim: Wood Entry Door Types: Wooden with window Condition: Requires maintenance Garage Door: Metal, sectional rollup Eave Type: Open overhangs with vented frieze blocking Condition: serviceable condition Foundation Foundation Type: Slab foundation Foundation Material: Poured concrete Slope and Drainage Direction of Lot Slope: Is relatively flat Condition: serviceable condition Drains Connected to: Municipal Gutters Downspouts Drain: Below grade Drives Walks and Patios Driveway Types: Concrete Condition: serviceable condition Walkway Type: Concrete Patio Type: A concrete Patio Locations: In the back Fence and Gate: Wooden Condition: In need of repair(s) 1. MONITOR: This structure has a pressed-type siding installed. It is common for this type of material to swell and hold moisture. It is imperative for this siding to be kept sealed with a high-density paint and for all joints to be kept sealed and/or caulked. There is a high probability of hidden damage with this type of material.

Page 9 of 20 2. REPAIR: There are one or more areas where the trim is damaged. Exterior trim is the most vulnerable to attack by rot, and it doesn t have to be very old. These areas left unattended can lead to further damage. We recommend contacting a competent carpenter for repairs. 3. REPAIR: Evidence of cracking in the patio slab was noted. We recommend sealing all cracks so water infiltration does not occur. 4. REPAIR: The fence is damaged. We recommend contacting a fencing contractor for repair. 5. REPAIR: Portions of the eaves are badly deteriorated and need to be replaced. I recommend immediate replacement by a competent carpenter. 6. IMPROVE: There are various plants and or bushes next to the exterior wall(s). Recommendation: Trim or prune all vegetation in such a way as to allow a minimum of six inches of clearance between the plant and the exterior wall. This is necessary in order to prevent damage to the exterior and to inhibit the ability of insects to migrate into the building structure. 7. FURTHER INSPECTION: Portions of the exterior were inaccessible due to a shed. Upon request and for an additional charge we will return to inspect these areas when they have been made accessible by others. We make no representation of inaccessible areas.

Page 10 of 20 8. IMPROVE: The side garage door is weathered. We recommend repairing or replacing the side garage door. Inspectors are NOT required to inspect or report on the presence or condition of recreational facilities, outbuildings, seawalls, breakwalls and docks, window and door screening, shutters, awnings or similar seasonal accessories.

Page 11 of 20 SECTION 3: Roof Coverings In accordance with the ASHI standard of practice pertaining to Roof Systems, this report describes the roof coverings and the method used to inspect the roof. Inspectors are required to inspect the roof covering, roof drainage systems, flashings, skylights, chimneys and roof penetrations. Roof Covering Roof Inspected: By walking the entire surface Roof Slope: Is a pitched style Roof Style: Hip and gable style Roofing Materials: Tile Material Flashing Flashing Type: Galvanized steel Flashing Locations: Roof to wall intersections and Base of the chimney(s) Condition: serviceable condition Gutters Downspouts Gutter Downspout Type: Metal Gutters Downspouts Drain: Below grade 1. IMPROVE: Trees or branches overhang the house. This condition, if allowed to continue, could result in damage to either the roof covering or the siding on the home. Recommendation: Trim branches to provide at least a six-inch separation between roof or wall and tree branches. 2. REPAIR: One or more of the tiles on the roof is not secured and slipped out of position. Recommendation: Repair as appropriate by a licensed roofing contractor. Inspectors are NOT required to inspect antennae, interiors of chimneys or flues that are not readily accessible or other installed accessory items.

Page 12 of 20 SECTION 4: Attic Areas and Roof Framing In accordance with the ASHI standard of practice pertaining to Insulation and Ventilation Systems, this report describes the insulation and vapor retarders used in unfinished spaces when readily accessible and the absence of insulation in unfinished spaces at conditioned surfaces. Inspectors are required to inspect insulation and vapor retarders in unfinished spaces when accessible, ventilation of attics and foundation (crawlspace) areas and mechanical ventilation systems, if present. Inspectors are NOT required to determine indoor air quality or disturb insulation or vapor retarders, unless required by law.

Page 13 of 20 SECTION 5: Plumbing In accordance with the ASHI standard of practice pertaining to Plumbing Systems, this report describes the water supply, drain, waste and vent piping materials and the water heating equipment, energy source and location of the main water and main fuel shutoff valves, when readily viewable or known. Inspectors are required to inspect the interior water supply and distribution systems, all fixtures and faucets, the drain waste and vent systems (including all fixtures for conveying waste), the water heating equipment (vent systems, flues and chimneys of water heaters or boiler equipment), fuel storage and distributions systems for water heaters and/or boiler equipment and drainage sumps, sump pumps and associated piping. Supply and Piping Service Piping Size: 1 1/2-inch Service Piping Type: Copper Branch Piping Type: Copper Fixtures/Faucets Supports/Insulation Functional Flow: Serviceable Function Drainage: Serviceable Waste Piping: Cast iron Condition: Serviceable Vent Piping: Cast iron Water Heater Water Heater Type: A conventional storage tank Water Heater Energy Source: Natural gas Capacity: 50 Gallons Make: State Select Water Heater Location: Garage Water Heater Vented: Through roof Sump Pump Main Water Shut Off Location: front of house 1. REPAIR: The showerheads in the upstairs and downstairs baths are missing. Recommend repair as appropriate by a licensed plumbing contractor. Inspectors are NOT required to inspect the connections for clothes washing machines, interiors of flues or chimneys when not readily accessible, wells or well pumps, equipment associated with water storage, water conditioning equipment, solar water heating components or systems, fire sprinkler or irrigation systems or private waste disposal (septic) systems. Additionally, inspectors are not required to operate safety valves or shut-off valves of any kind. We DO NOT determine the quantity or quality of water supplies or whether water supply and waste disposal systems are public or private.

Page 14 of 20 SECTION 6: Electrical Systems In accordance with the ASHI standard of practice pertaining to Electrical Systems, this report describes the amperage and voltage rating of the service, the location of the main disconnect and any sub panel(s), the presence of solid conductor aluminum branch circuit wiring and the absence of smoke detectors. Inspectors are required to inspect the viewable portions of the service drop from the utility to the house, the service entrance conductors, cables and raceways, the service equipment and main disconnects, the service grounding, the interior components of the service panels and sub panels, the conductors, the over-current protection devices (fuses or breakers), ground fault circuit interrupters and a representative number of installed lighting fixtures, switches and receptacles. Service Entry Service Drop Type: Underground service lateral Service Entry Conductor: Copper Service Ground Conductor: Copper Service Ground Location: Ufer ground Meter Location: Inaccessible Main Disconnect Main Disconnect Type: Inaccessible Main Panel Service Entrance Panel Location: inaccessible Panel Type: No label Sub Panel Sub Panel Location: Bedroom closet Sub Panel Type: Challenger Sub Panel Style: Breaker system Sub Panel Amperage Rating: 125 amp Sub Panel Voltage Rating: 120/240 volt 1. REPAIR: The main panel was inaccessible due to bushes. We recommend making the panel accessible and then have it re-inspected. 2. REPAIR: There are light fixtures loose/ missing with the wiring exposed in the attic. We recommend installing a new fixture. Inspectors are NOT required to inspect any remote control devices (unless such device is the only means of control), alarm systems and associated components and controls, low-voltage wiring systems or components or any ancillary wiring, systems or components that are not part of the primary power distribution system. We are also NOT required to measure amperage draw, line voltage or ground impedance.

Page 15 of 20 SECTION 7: Heating Systems In accordance with the ASHI standard of practice pertaining to Heating Systems, this report describes the energy source and the distinguishing characteristics of the heating system(s). Inspectors are required to inspect the installed heating equipment and associated vent systems, flues and chimneys. Heating Systems Type of Heating System: A natural gas forced air furnace Condition: Started as expected using normal controls Heating System Access: garage Location Electric Safety Switch: Within sight of the furnace Furnace Make: Carrier BTU: 75,000 Exhaust Exhaust Vent Type: Double-wall metal Exhausts Through: Vents up through the roof 1. MONITOR: At the time of this inspection we started the furnace and it heated at normal working temperature. When we completed the test we turned off the furnace 2. MONITOR: At the time of this inspection the readings in the registers all were above 100 degrees at the registers. Inspectors are NOT required to inspect the interiors of flues or chimneys when not readily accessible, the heat exchanger(s) of boilers or furnaces, humidifiers or dehumidifiers, electronic air cleaners or any solar space heating system(s). We are also NOT required to determine the adequacy of the heating system or distribution/balance of heat throughout the home.

Page 16 of 20 SECTION 8: Central Air Conditioning In accordance with the ASHI standards of practice pertaining to Air Conditioning Systems. Inspectors are required to inspect only installed central or through-wall air conditioning units and to describe their distinguishing characteristics and energy source. Coil Condenser Outside Unit Location: Exterior at rear 1. MONITOR: At the time of this inspection the readings in the registers all were below 60 degrees at the registers. 2. MONITOR: At the time of this inspection we were able to start the air conditioning system and it cooled at the normal working temperature. At the end of the test we turned the unit off.. Inspectors are NOT required to inspect electronic air cleaner filters or determine the adequacy of the air conditioning system or whether it is properly balanced. We DO NOT operate any cooling system equipment, including the cooling cycle of heat pumps, when the exterior temperature is less than 60 F.

Page 17 of 20 SECTION 9: Fireplaces and Chimneys In accordance with the ASHI Standards of Practice pertaining to Fireplaces and Solid Fuel Burning Appliances, this report describes the fireplaces and solid fuel burning appliances as well as the chimneys. Those portions of the chimney(s) that extend above the roof are described under Roof System previously in this report. Inspectors are required to inspect system components, vent systems, flues and chimneys of fireplaces and solid fuel burning appliances. Main Fireplace (Living room) Fireplace Type: Wood-burning insert Fireplace Location: Living room Fireplace Liner: Metal Inspectors are NOT required to ignite or extinguish any fires in any device, determine the draft characteristics of vents or chimney flues, move fireplace inserts, stoves or firebox contents, inspect the interior of flues or chimneys, fire screens or doors, seals and gaskets, automatic fuel feed devices, combustion make-up air devices, mantels and fireplace surrounds or any heat distribution accessory devices, whether gravity controlled or fan assisted.

Page 18 of 20 SECTION 10: Building Interior In accordance with the ASHI standard of practice pertaining to Interiors, there is NO requirement for the report to describe any interior components or finishes. Inspectors are required to inspect walls, ceilings and floors, steps, stairways and railings, countertops and a representative number of cabinets, a representative number of doors and windows and the garage doors and automatic garage operators. Room Interior Heat Source: A forced air furnace vent Wall Surface Type: Sheetrock Flooring Type: Carpeting, Sheet vinyl, Laminate and Tile Kitchen Flooring Material: Tile Kitchen Counter Top Type: Granite Cabinets and Counters Kitchen Cabinet Type: Wood Condition: Serviceable condition Bathroom Flooring Material: Tile Condition: Serviceable condition Bathroom Counter Top Type: Cultured marble Bathroom Cabinet Type: wood Inside Door Type: Hollow core wood panel Windows and Doors Window Frame Type: Vinyl Window Pane Type: Double glazed Condition: Serviceable condition Garage Door Garage Door Type: Metal, sectional rollup Garage Door Opener: Automatic Garage Walk through Door: Serviceable Garage Walk Through Door Fire Separation Walls and Ceilings 1. IMPROVE: Small carpet stains are visible at random areas of the home. We recommend having the carpets cleaned.

Page 19 of 20 2. SAFETY ISSUE: The shower door top rail in the downstairs bathroom is not connected by a safety screw to the side rails. The safety screw holds the top rail to the side rails so the doors and top rail do not come off the side rail causing injuries. We recommend installing a safety screw. 3. REPAIR: The hood vent/micro vent does not work. We recommend contacting an appliance repairman or just replacing the hood. 4. REPAIR: The pedestrian door between the garage and the house is incorrect because it is missing one of the following. A pedestrian door really should be a 20-minute fire-rated type, have tight-fitting gaskets, be fitted with a self-closing hinge and able to close and latch itself easily without binding. This ensures that the door won't be left open allowing vehicle exhaust, chemical fumes or smoke to enter the house. This door may not have needed to meet these requirements under local code at the time of original construction. Because these standards have been established in the interest of health and safety, I recommend having the door brought into full compliance with current standards. Another requirement for the entry door from the garage into the house is to be slightly elevated / higher than the garage floor surface. Many building codes require a step (or curb) between the house door and the garage floor. The step (min 4? recommended, but check your local code) prevents spilled gasoline vapors from entering the house and partially protects residents from carbon monoxide fumes. 5. REPAIR: The door handle on the side garage door is loose. We recommend repairing as necessary. Inspectors are NOT required to inspect paint, wallpaper or other finish treatments, carpeting, window treatments, central vacuum systems, household appliances and recreational facilities or gymnastic equipment.

Page 20 of 20 GENERAL LIMITATIONS AND EXCLUSIONS The ASHI Standards of Practice are applicable to buildings with four or fewer dwelling units and their garages or carports. They are the bare minimum standard for a home inspection, are not technically exhaustive and do not identify concealed conditions or latent defects. Inspectors are NOT required to determine the condition of any system or component that is not readily accessible; the remaining service life of any system or component; the strength, adequacy, effectiveness or efficiency of any system or component; causes of any condition or deficiency; methods materials or cost of corrections; future conditions including but not limited to failure of systems and components; the suitability of the property for any specialized use; compliance with regulatory codes, regulations, laws or ordinances; the market value of the property or its marketability; the advisability of the purchase of the property; the presence of potentially hazardous plants or animals including but not limited to wood destroying organisms or diseases harmful to humans; the presence of any environmental hazards including, but not limited to toxins, carcinogens, noise, and contaminants in soil, water or air; the effectiveness of any system installed or methods utilized to control or remove suspected hazardous substances; the operating costs of any systems or components and the acoustical properties of any systems or components. Inspectors are NOT required to operate any system or component that is shut down or otherwise inoperable; any system or component which does not respond to normal operating controls or any shut off valves. Inspectors are NOT required to offer or perform any act or service contrary to law; offer or perform engineering services or work in any trade or professional service other than home inspection. Inspectors DO NOT offer or provide warranties or guarantees of any kind unless clearly explained and agreed to by both parties in a formal pre-inspection agreement. Inspectors are NOT required to inspect underground items including, but not limited to underground storage tanks or other underground indications of their presence, whether abandoned or active; systems or components that are not installed; decorative items; systems or components that are in areas not entered in accordance with the ASHI Standards of Practice; detached structures other than carports or garages; common elements or common areas in multi-unit housing, such as condominium properties or cooperative housing. Inspectors are NOT required to perform any procedure or operation which will, in the opinion of the inspector, likely be dangerous to the inspector or others or damage the property, its systems or components; move suspended ceiling tiles, personal property, furniture, equipment, plants, soil, snow, ice or debris or dismantle any system or component, except as explicitly required by the ASHI Standards of Practice. Inspectors are NOT required to enter under-floor crawlspaces or attics that are not readily accessible nor any area which will, in the opinion of the inspector, likely be dangerous to the inspector or others persons or damage the property or its systems or components. Inspectors are not limited from examining other systems and components or including other inspection services. Likewise, if the inspector is qualified and willing to do so, an inspector may specify the type of repairs to be made. The inspector may also exclude those systems or components that a client specifically requests not be included within the scope of the inspection. If systems or components are excluded at the request of the client they are listed herein.