Household air pollution in South African low-income settlements: a case study

Similar documents
Indoor and outdoor particulate matter concentrations on the Mpumalanga highveld A case study

Comparison of Respirable Particulate (PM4) Measturements from Direct- Reading Photometric Instruments and a Gravimentric Sampling Method

Correcting respirable photometric particulate measurements using a gravimetric sampling method

Air quality monitoring and management for the industrialized Highveld region of South Africa

LEVELS AND DETERMINANTS OF INDOOR AIR POLLUTION EXPOSURE IN YOUNG GUATEMALAN CHILDREN

The effect of particle size and pyrolysis on the performance of low-smoke fuels in coal stoves

Burden of disease from household air pollution for 2016 Description of method

THE EXECUTION OF A HOUSEHOLD EMISSION OFFSET PILOT STUDY IN THE HIGHVELD PRIORITY AREA, MPUMALANGA

Is Hourly Particulate Matter Sampling the Answer to Burning Questions in Modelling and Health?

Air pollution health impact assessment: PM 2.5 exposures, sources and components

Environmental Air Quality Exposure Assessment in a Rural Nigerian Village

REDUCING INDOOR AIR POLLUTION THROUGH PARTICIPATORY DEVELOPMENT IN RURAL KENYA

EXPOSURE ASSESSMENT FOR A RURAL COMMUNITY USING BIOMASS FUEL IN TRADITIONAL AND IMPROVED STOVES

Potential Impact of Biomass Burning on Urban Air Quality: Case-study of Chiang Mai

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

Beachville, Oxford County Particulate Matter Sampling. Contact information:

AIRBORNE PARTICULATE MATTER AT A BUS STATION: CONCENTRATION LEVELS AND GOVERNING PARAMETERS

Identifying the PCA-Resolved Components by Source tracer Elements

Residential heating with wood and coal: Health impacts and policy options

MEAN ANNUAL EXPOSURE OF CHILDREN AGED 0-4 YEARS TO ATMOSPHERIC PARTICULATE POLLUTION

Nez Perce Tribe Woodstove Study & Change Out

RESEARCH, TESTING AND DEVELOPMENT SUSTAINABILITY KWAZAMOKUHLE AIR QUALITY REPORT JANUARY 2016

Air Pollution and Child Health in Urban India Arkadipta Ghosh and Arnab Mukherji

THE EQUATION IS SIMPLE.

Dispersion of Respirable Particles Emitted from Surface Mining Operations

An Introduction to Air Quality

BREATHE A LITTLE EASIER WITH TSI

Household fuel use and acute respiratory infections among younger children: an exposure assessment in Shebedino Wereda, Southern Ethiopia

Impact of Energy Efficiency of Cook stoves on Indoor Air Quality A Case Study in the Estate Sector Households of Sri Lanka

OUT DOOR AIR QUALITY AND HEALTH EFFECTS: A CASE STUDY

Initial Sand Mine and Processing Plant Particulate Levels. Crispin Pierce PhD University of Wisconsin-Eau Claire 20 January 2013

WHO ambient (outdoor) air quality database Summary results, update 2018

Moving Beyond Coal? Household Fuel Transition & Ambient PM Pollution in Peri-Urban Beijing

Burden of disease from ambient air pollution for 2016 Description of method

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

RESEARCH, TESTING AND DEVELOPMENT SUSTAINABILITY DEPARTMENT EZAMOKUHLE AIR QUALITY MONTHLY REPORT FEBRUARY 2017

Air quality modelling in London LAEI2013

COEGA DEVELOPMENT CORPORATION OUR APPROACH TO AIR QUALITY MANAGEMENT IN THE COEGA SEZ 1 OCTOBER 2018

Domestic Heating: an increasingly important source of PM and PAHs driven by Climate Mitigation Policies

Draft Small-scale Methodology AMS-II.G: Energy efficiency measures in thermal applications of non-renewable biomass

MEASUREMENT AND ANALYSIS OF AMBIENT AIR QUALITY IN A COMMERCIAL AREA -A CASE STUDY OF GORAKHPUR CITY

MEASUREMENT AND ANALYSIS OF AMBIENT AIR QUALITY IN A COMMERCIAL AREA -A CASE STUDY OF GORAKHPUR CITY

ASSESSMENT OF AMBIENT AIR QUALITY IN ESKISEHIR, TURKEY

AN ON-LINE FUGITIVE DUST MONITORING NETWORK

Assessment of atmospheric trace metals in the western Bushveld Igneous Complex, South Africa. PG van Zyl et al., 30 September 2013

Thirty-First Quarterly Report of Ambient Air Quality Monitoring at Sunshine Canyon Landfill and Van Gogh Elementary School

LABORATORY STUDY OF POLLUTANT EMISSIONS FROM WOOD CHARCOAL COMBUSTION FOR INDOOR SPACE HEATING IN CHINA

Relationship between quality of ambient air and respiratory diseases in the Polish population

HEALTH IMPACT OF PM 10 AND OZONE IN 13 ITALIAN CITIES

Air quality impacts of the Bulkley Valley and Lakes District woodstove exchange program

Woodstove Changeout Results of the Libby, Montana and Nez Perce In-Home PM 2.5 Studies

I. INTRODUCTION. G:\HEnv\Files\Subject Areas\Air\MonitoringAirQ\Studies\SeeleyLake_PM2.5_Saturation2010\SL_PM25_StudyReport(2)_

Statistics for Quality Assurance of Ambient Air Monitoring Data

Version Certificate: /

Health Impact of. in Developing Countries

Volatile organic pollution in highly populated areas in South Africa

Small-scale Methodology Energy efficiency measures in thermal applications of non-renewable biomass

Eskom s Air Quality Offsets Implementation Plan for Lethabo Power Station

Greschbachstrasse 3b, Kahlsruhe Germany

Near reference sensors and their application. February 13 th, 2017 Hannamari Jaakkola, Vaisala Oyj

Cooking as a source of indoor air pollution in rural areas of Tanzania

Prabjit Barn Santé et environment: enjeux, rôles et interventions June 3, 2010 Montreal, QC

Determinants of exposure to household air pollution in rural Malawi. By Sangeetha Kumar

2. About this catalogue

AWARENESS, ATTITUDE AND PRACTICE TOWARDS INDOOR AIR POLLUTION (IAP) AMONGST RESIDENTS OF OKE OYI IN ILORIN

STATE OF THE AIR QUALITY IN THE MAIN REGIONS OF PEARL RIVER DELTA

Meteorological Influences on Concentration of Airborne Particulate Matter in Ulsan, Korea

Paraffin Safety Association

Ambient Air Quality and noise Measurements Report Gas pressure reduction station in Marsa Matrouh Governorate

Impact of Improve Cook Stove in the Rural Area: A case Study of Rimuwa Gulmi Nepal

AN ESTIMATE OF GREENHOUSE GAS EMISSIONS FROM COMMON KENYAN COOKSTOVES UNDER CONDITIONS OF ACTUAL USE

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

Salem, Massachusetts

Waterview Operational Air Quality Monitoring Report January 2018

Characteristics of the particulate matter in Riyadh city, Saudi Arabia

ASPECTS CONCERNING THE MODELING OF THE AIR POLLUTANTS DISPERSION

Overwiev of AIRUSE project issues by ARPA Lombardia. Cristina Colombi Vorne Gianelle AIRUSE

Particulate Monitors and Samplers

Baseline Scenario of Energy Consumption of Urban Multi- Storey Residential Buildings in India

Indoor Air Quality (IAQ) Measurements and Modeling of Homes during Periods of Intensive Wildfire Smoke

Characteristics and Climate Implications of Particles Generated by Traditional Wood Burning Cookstoves. Christoph Roden March 29, 2005

Evaluation of air quality in the Miechów district, Poland

Domestic Biomass Burning in Africa

United Nations Environment Assembly (UNEA) Side Event: Improving Air Quality in African Cities June 23, :15 to 2:45 Conference Room 9

Exposure to ambient air pollution from particulate matter for 2016

24 August Leanne Cross Senior Environmental Planner KDC Via

Thirtieth Quarterly Report of Ambient Air Quality Monitoring at Sunshine Canyon Landfill and Van Gogh Elementary School

Twenty-Third Quarterly Report of Ambient Air Quality Monitoring at Sunshine Canyon Landfill and Van Gogh Elementary School

Effect of PM2.5 on AQI in Taiwan

18th International Conference on Harmonisation within Atmospheric Dispersion Modelling for Regulatory Purposes 9-12 October 2017, Bologna, Italy

Supporting Information. Temporal Characteristics of Brown Carbon over the Central Indo- Gangetic Plain

Thirty-Fourth Quarterly Report of Ambient Air Quality Monitoring at Sunshine Canyon Landfill and Van Gogh Elementary School

Coggins, Marie; Broderick, Aine; Byrne, Miriam. /s8f92c

INDOOR AND OUTDOOR PARTICLE MEASUREMENTS IN A STREET CANYON IN COPENHAGEN

Household air pollution from solid cookfuel use

Chemical composition and source apportionment of PM 1.0, PM 2.5 and PM in the roadside environment of Hong Kong

Re-calculation of the odour emission of a thermal treatment plant for waste by using a Monte-Carlo based model

Preventing NCD deaths through better air quality

Influence of Building Orientation on the Indoor Climate of Buildings

Indoor Air Pollution Monitoring Summary. for. Gaia Association-Ethiopia s CleanCook Stove Tests

Transcription:

This paper is part of the Proceedings of the 24 International Conference th on Modelling, Monitoring and Management of Air Pollution (AIR 2016) www.witconferences.com Household air pollution in South African low-income settlements: a case study B. Language, S. J. Piketh, B. Wernecke & R. Burger Unit for Environmental Sciences and Management, North-West University, South Africa Abstract Residential solid fuel combustion emission within low-income communities result in increased negative health impacts within these settlements. The Highveld is considered to be the industrial epicentre of South Africa as it houses 11 of the 13 coal-fired power stations situated within the country s borders. The availability of low-cost coal within the area makes it the fuel of choice for heating and cooking purposes within low-income settlements. As a result residents of these settlements are continuously exposed to high concentrations of air pollutants. A paucity in data, on the impact of residential solid fuel combustion, exists since research is mainly focussed on industrial emission impacts. This paper aims to accurately quantify and characterise the mass concentrations of particulate matter experienced within both the indoor (PM 4 ) and ambient (PM 10, PM 2.5 ) environments of KwaDela, a low-income settlement located on the South African Highveld. Furthermore, an attempt was made to link the indoor and ambient particulate mass concentrations, identify diurnal patterns and seasonal variations. KwaDela experiences high levels of particulate pollution, within both the indoor and ambient environment, as a result of domestic solid fuel combustion. Energy use varies seasonally with higher consumption of solid fuels during the winter leading to increased particulate loading. The concentrations of respirable particulate concentrations within the indoor environment are significantly higher than PM 10 and PM 2.5 experienced in the ambient environment. This indicates that the effect of respirable particulate matter, associated with solid fuel combustion in the indoor environment, has been underrepresented and thus its effect on health underreported. Keywords: indoor, ambient, air quality, particulate matter, low-income settlements, South Africa. doi:10.2495/air160211

228 Air Pollution XXIV 1 Introduction Research has mainly focused on ambient air pollution; however, in recent years this focus has shifted toward indoor air pollution studies. Studies have identified significantly higher concentrations of pollutants within indoor environments than previously thought [1]. More recently, however, studies have shown that pollutants in the ambient environment are also found within the indoor environment, every so often even at higher concentrations [2]. It is estimated that around 2.8 to 3 billion people rely on solid fuel combustion as a primary energy source which leads to increased levels of air pollution associated with household emissions [3]. This is especially true within developing countries where solid fuels undergo incomplete combustion within poorly constructed or makeshift stoves [4]. Particulate pollution originating from the incomplete combustion of solid fuels have negative health effect on those that are exposed to it [5]. The 2010 Global Burden of Disease estimates that the use of solid fuels resulted in an estimated 3.5 (uncertainty: 2.7, 4.5) million premature deaths in 2010, while the World Health Organisation (WHO) estimates 4.3 million premature deaths [3]. South Africa is characterised as a developing country and is home to numerous middle- to low-income settlements. These settlements were built as low-cost housing developments, by the South African Government based programmes known as the Reconstruction and Development Program (RDP). Most of these settlements were developed in existing informal townships on urban boundaries and in rural areas. During the past decade many issues surrounding the RDP developments have arisen, these include: i) RDP developments do not address the problems surrounding poverty in these areas; and ii) the structures and infrastructures are of poor quality and require increasing maintenance [6]. A significant proportion of middle- to low-income settlements, which are predominantly made up of RDP houses tend to implement the use of residential solid fuel combustion as a primary source of energy due to increased levels of poverty and the high cost of electricity. How does the use of solid fuels within the settlement impact on the residents of these settlements? This paper aims to accurately quantify the particulate concentrations experienced within a typical South African low-income settlement prone to the residential combustion of solid fuels (coal). This is achieved by answering the following research questions i) what is the primary energy source used in the settlement; ii) what are the ambient and indoor particulate concentrations within the settlement; iii) what is the relationship between ambient, indoor, and personal particulate concentration measurements; and iv) what are the associated diurnal patterns and seasonal variations of ambient and indoor particulate concentrations. 2 Materials and methods 2.1 Study area description and site selection KwaDela (26 27 47.53 S; 29 39 51.73 E) is situated between Ermelo and Bethal, in the Gert Sibande District Municipality, which is approximately 200 km south-

Air Pollution XXIV 229 east of Johannesburg (Figure 1). The settlement lies within the appropriately termed Highveld Priority Area, which represents an area of particularly high ambient air pollution levels. It is primarily directly surrounded by natural grasslands and land used for commercial cultivation, thus to a certain degree it is isolated from large industrial activities. Sources that potentially contribute the state of ambient air quality within the settlement includes traffic from the N17 route as well as within the settlement itself, the railway line, waste burning within the settlement, and residential solid fuel combustion. According to the 2011 South African National Census data the settlement has a total population of 3777 people occupying 984 households. Each household has an average of 4.1 inhabitants. KwaDela is classified as a low-income settlement as the mean monthly income per household is below R1500, which is equivalent to approximately $100. 2.2 Experimental design Sampling was conducted over a period of two years, consisting of two winter and two summer sampling campaigns. The winter campaigns were performed during the months of July to September, while the summer campaigns were performed during February to May. Each sampling campaign stretched approximately 10 to 12 weeks. The winter sampling campaigns represent the worst case scenario and the summer the best. The reasons for this is i) winter have improved dispersion potential due to existing high pressures, and ii) less burning is expected during summer due to higher ambient temperatures. Ambient monitoring was done by utilising a mobile monitoring station. The monitoring station was situated in an open area close to the centre of the settlement (Figure 1). This was done as to get the best possible representation of the ambient air quality within the settlement, without influences from external sources. The monitoring station housed various instruments, continuously monitoring both gaseous and particulate pollution as well as meteorological parameter (temperature, pressure, humidity, rainfall, wind speed and direction). Among these instruments were the MetOne BAM 1020 (measuring PM 10 ) and the MetOne E-BAM (measuring PM 2.5 ). A total of 207 households, thus 21% of the settlement, were subjected to a structured interviewer-questionnaire. This provide information related to household energy use and perceived quality of life. The interviewed households complied with the following minimum requirements: i) they were RDP programme houses consisting of two bedrooms, a living room, and a kitchen area; ii) there were no additional extensions to the original house; and iii) informed consent was given by participants. Indoor and personal sampling, related to the respirable fraction of particulate matter (PM 4 ), was conducted within twenty randomly selected households (from those that participated in the structured interviewer-questionnaires). A network of photometric light scattering instruments (DustTrak 8520 (x4); DustTrak II 8530 (x4), and SidePak AM510 (x8)) were deployed within the selected houses. The DustTrak s were placed within the indoor kitchen area (area of solid fuel combustion) or as close to the area as possible. The SidePak instruments were

230 Air Pollution XXIV Figure 1: Map of KwaDela low-income settlement in Mpumalanga, South Africa. The spatial distribution of the ambient mobile monitoring station and households utilised for indoor and personal sampling are also indicated. personally carried by one member of the household during the day, thus it includes particulate concentrations from ambient and indoor sources. These instruments were fitted with 10-mm Nylon Dorr-Oliver Cyclone inlets and sampled at a flow rate of 1.7 L.min -1 (±5%). The cyclone provided the 4 µm cut size. The instruments were rotated every two weeks. Additionally, temperature ibuttons were located in each room within the house, at a distance on 10cm from the stove chimney as well as externally (on the south-facing wall). This was done so as to provide data on the temperature dynamics of the houses including the burning cycles. The above mentioned methodological approach was approved by North- West University ethical committee. 2.3 Data collection and analysis The mobile monitoring station recorded data at 1-min averaging intervals, while the photometric instruments were set to 5-min averaging intervals. Site visits were conducted on a weekly basis to collect data and perform general maintenance (filter, zero and flow checks as per manufacturer s instructions) on the instruments. The data were combined into a single dataset, for each season, containing all relevant parameters. It is important to note that a photometric calibration factor (PCF) of 0.715 was applied to the PM 4 measurements. This PCF was obtained by comparing continuous and gravimetric PM 4 mass concentrations sampled within

Air Pollution XXIV 231 the indoor solid fuel (coal) burning environment of a low-income settlement (KwaZamokuhle) on the South African Highveld. The datasets underwent general descriptive statistical- and regression analyses. The regression analyses provided the correlation associated with the particulate concentrations. Additionally the datasets were averaged hourly and plotted on simple time-series as to obtain the diurnal patterns associated with each season. Finally, the daily averages for each season were computed and compared to the WHO standards set for particulate matter. This was done for a two week case study period during winter 2013 and summer 2014. 3 Results and discussion 3.1 Study population The majority (97.10%) of households have access to electricity, however, there is still a high rate of solid fuel use coal (75.36%) and wood (63.28%). Note that 40.57% of households use a combination of these fuels. Wood is used in smaller quantities in all houses as it serves as an ignition source for coal. Household energy use and consumption varies between the sampling seasons. Coal is primarily used for cooking and heating purposes during winter months. Burning occurs at specific times, namely i) 4 to 6 AM; ii) 6 to 9 AM; iii) 4 to 6 PM; and iv) 6 to 9 PM. Cast-iron stoves are used by 61% of households, followed by welded stoves (11.5%). 3.2 Household PM measurements and relationships Residents are exposed to high particulate levels associated with domestic solid fuel combustion. Particulate concentrations, ambient and indoor, show significant changes between winter- and summer sampling campaigns (Table 1). The mean ambient levels (Table 1) vary significantly between seasons. Ambient PM 10 concentrations are 102.1 ± 76.96 and 99.29 ± 61.39 (µg.m -3 ) respectively, and summer concentrations are 50.43 ± 29.59 and 66.03 ± 25.86 (µg.m -3 ). PM 2.5 concentrations show less seasonality compared to PM 10. Finer aerosols were lower than the coarse fraction by a factor of 4 to 5 (winters) and 2 to 3 (summers). From this point forwards, ambient particulate concentrations will be represented by PM 2.5 and indoor by PM 4. Indoor particulate concentrations are higher than ambient by factor of 7 in the winter. Summer particulate concentrations (indoor and ambient) are more comparable. Personal exposure to particulate matter is closely related to the particulate concentrations within the indoor- than ambient environment. A summary of the correlation between ambient, indoor and personal PM mass concentrations measurements are given in Table 2. The regression analysis indicated a moderate correlation between winter 2014 ambient PM 2.5 and personal PM 4 concentrations as well as indoor and personal PM 4 (R 2 = 0.32 and 0.34 respectively). There is a moderately strong correlation (R 2 = 0.43) between ambient PM 2.5 and personal PM 4 measurements. The strongest correlation (R 2 = 0.93) exists between indoor and personal PM 4 during summer 2015.

232 Air Pollution XXIV Table 1: Summary of the descriptive statistics associated with the seasonally time-integrated (1-min) ambient, indoor and personal (5-min) particulate measurements. Ambient Ambient Indoor Personal Ambient Ambient Indoor Personal PM10 PM2.5 PM4 PM4 PM10 PM2.5 PM4 PM4 Winter 2013 Summer 2014 Mean 102.10 23.96 190.80 109.60 50.43 21.61 56.53 87.07 SD 76.96 11.39 626.26 382.71 29.59 12.31 184.51 255.55 Max 843.00 206.00 14680.00 5131.00 325.20 119.00 1288.00 5909.00 Min 4.47 1.73 0.07 0.01 6.71 7.73 3.58 0.01 Median 86.13 21.38 58.18 46.31 42.64 19.03 19.30 41.47 N 1420 1901 2648 438 2241 1368 2414 49.00 Winter 2014 Summer 2015 Mean 99.29 27.89 175.60 61.77 66.03 18.64 117.70 84.84 SD 61.36 22.20 518.16 76.21 25.86 9.30 259.42 127.33 Max 447.40 207.50 14110.00 469.20 174.30 153.20 2621.00 525.60 Min 21.85 1.79 0.09 10.81 20.55 0.07 0.26 2.15 Median 88.94 22.51 55.95 40.60 60.25 16.73 47.07 37.45 N 903 1660 1179 39 2076 5148 5270 105 Table 2: Summary of the regression analyses between ambient, indoor, and personal particulate measurements. R 2 Standard Error R 2 Standard Error Winter 2013 Summer 2014 Ambient PM2.5 / Indoor PM4 0.0098 0.1689 0.0002 0.1636 Ambient PM10 / Indoor PM4 0.0325 0.4224 0.0020 0.2020 Ambient PM2.5 / Personal PM4 0.0064 1.764 0.4346 1.113 Ambient PM10 / Personal PM4 0.0013 0.2044 0.0638 0.8441 Indoor PM4 / Personal PM4 0.0324 0.0302 0.0155 0.9100 Winter 2014 Summer 2015 Ambient PM2.5 / Indoor PM4 0.0101 0.5860 0.0069 0.8348 Ambient PM10 / Indoor PM4 0.0149 0.2776 0.0178 0.1676 Ambient PM2.5 / Personal PM4 0.3249 0.571 0.0040 2.023 Ambient PM10 / Personal PM4 0.0266 0.2424 0.1334 0.3434 Indoor PM4 / Personal PM4 0.3417 0.1207 0.9358 0.0101

Air Pollution XXIV 233 3.3 Diurnal patterns and season variations The diurnal pattern of hourly averaged particulate concentrations associated with each season (Figure 2) is very distinctive. Winters are marked with lower mean ambient temperatures ranging between 4 and 20 C, while individual measurements reach sub-zero during the evenings. Summer averages range from 10 28 C. The peaks in particulate concentrations, for both the ambient and indoor environments, correspond with lower ambient temperatures. Winter particulate concentrations peak for an extended time (~4 6 hours), compared to summer (~2 4 hours). The indoor concentrations are substantially higher during winter due to i) the majority of the residential solid fuel combustion occurs indoors; and ii) the lack of ventilation resulting from closed doors and windows keeping the heat inside. It is important to note that the peaks in the indoor environment corresponds directly to the increased temperatures measured at the stoves. These Winter 2013 Ambient and Personal Winter 2013 Indoor (a) (b) Summer 2014 Ambient Summer 2014 Indoor and Personal (c) (d) Figure 2: Diurnal patterns for hourly averaged ambient (PM 10 and PM 2.5 ), indoor (PM 4 ) and personal (PM 4 ) particulate concentrations (µg.m -3 ). Categorised by season: winter 2013 (a) PM 10 and PM 2.5, (b) PM 4, summer 2014 (c) PM 10 and PM 2.5 and (d) PM 4.

234 Air Pollution XXIV trends are considered to be a signature trend for low level residential solid fuel burning activities, thus the particulate concentrations measured in both the ambient and indoor environment are directly influenced by the combustion of solid fuel within the residential area. 3.4 Case studies A two week period during winter 2013 (Figure 3(a) and (b)) and summer 2014 (Figure 4(a) and (b)) was randomly selected as case study. It is clear that there is a larger variability in both particulate concentrations and temperatures experienced during the two-week period of winter 2013 than summer 2014. The mean daily ambient temperatures range from 4 15 C (winter) and 14 20 C (summer). As previously mentioned increased combustion leads to increased level of respirable (a) (b) Figure 3: Time-series graphs of the daily PM averages measured over a two week period during winter 2013 for (a) ambient PM 10 and PM 2.5 as well as (b) indoor and personal PM 4.

Air Pollution XXIV 235 particulate concentrations within the indoor environment which can also be seen in the ambient concentrations, however, August 30th experiences a peak in ambient PM 10 and PM 2.5 whereas the indoor PM 4 is much lower than expected. The ambient PM 10 levels exceeds the 50 µg.m -3 WHO 24-hr PM 10 standard for the entire two-week winter period. This is also the case for the PM 2.5 levels compared to the 25 µg.m -3 WHO 24-hr PM 2.5 standard, except for the August 31st. The ambient PM 10 levels exceeds the 50 µg.m -3 WHO 24-hr PM 10 standard eight times during the two-week summer period, while PM 2.5 exceeds the 25 µg.m -3 WHO 24-hr PM 2.5 standard five times during this time. It is clear that particulate measurements will exceed the South African National Ambient Air Quality Standards, as they are higher than those set by the WHO. South Africa has no set (a) (b) Figure 4: Time-series graphs of the daily PM averages measured over a two week period during summer 2014 for (a) ambient PM 10 and PM 2.5 as well as (b) indoor and personal PM 4.

236 Air Pollution XXIV standard for indoor particulate pollution, thus the WHO 24-hr PM 10 and PM 2.5 standards were used as reference. The daily indoor PM 4 concentrations constantly exceed these standards, during both seasons. 4 Conclusion This study was designed to evaluate particulate matter associated with residential solid fuel combustion, within a typical low-income settlement in South Africa. The primary energy source used in domestic solid fuel combustion is coal long with small quantities of wood. Residents are exposed to increasingly high concentrations of respirable particulate matter within the indoor environment, which is higher than ambient concentrations by a factor of 7 during winter, while summer concentrations are more comparable. Personal particulate exposure is closely related to indoor particulate concentrations. Diurnal patterns and seasonal variation are distinctly associated with low-level residential solid fuel burning activities, with combustion times ranging from 2 4 hours in the summer between 4 and 6 hours in the winter. This paper is the first to represent data on the particulate concentrations experienced (indoor, ambient and personal), as a result of domestic solid fuel combustion, within a South African low-income settlement. References [1] Myers, I. & Maynard, R.L. Polluted air--outdoors and indoors. Occup. Med. (Lond). 55(6): 432 8, 2005. [2] Chen, B.H., Hong, C.J., Pandey, M.R., & Smith, K.R. Indoor air pollution in developing countries. World Health Stat. Q. 43(3): 127 138, 1990. [3] Bruce, N., Pope, D., Rehfuess, E., Balakrishnan, K., Adair-Rohani, H., & Dora, C. WHO indoor air quality guidelines on household fuel combustion: Strategy implications of new evidence on interventions and exposure-risk functions. Atmos. Environ. Elsevier Ltd. 106: 451 457, 2015. [4] Bruce, N., Perez-Padilla, R., & Albalak, R. Indoor air pollution in developing countries: a major environmental and public health challenge. Bull. World Health Organ. 78(9): 1078 1092, 2000. [5] Bruce, N., Perez-Padilla, R., & Albalak, R. The health effects of indoor air pollution exposure in developing countries. Geneva World Heal. Organ. Rep. WHO/SDE/OEH/02.05. :1 40, 2002. [6] Goebel, A. Sustainable urban development? Low-cost housing challenges in South Africa. Habitat Int. 31(3 4): 291 302, 2007.