XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES

Similar documents
U.V resistance UL Sunlight Resistance. Flame retardant IEC

EHV XLPE CABLES CDCC LINE

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

MATERIAL STANDARD FOR CABLES AND WIRES

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

SPECIFICATION FOR FRLS POWER CABLES

26/35kV Copper XLPE Insulation Electric Cable

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

INTERNATIONAL STANDARD

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

New designed XLPE-insulated cables substituting paper-insulated pipe type cables

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

MGVCL/MM/ 3Cx240 mm 2 XLPE Cables/2077 TECHNICAL SPECIFICATION FOR 11 KV XLPE POWER CABLE (CROSS LINKED POLYTHELENE DRY GAS CURED) SECTION I

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

40/69 kv to 127/220 kv XLPE

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

INSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES

THE PATHWAY TO POWER HIGH AND EXTRA HIGH VOLTAGE CABLES

This document is a preview generated by EVS

INTERNATIONAL STANDARD

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

11-SDMS-01 REV. 03 ( )

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.

Comparison of BS 5308, PAS 5308 and BS EN

15~35KV Termination Kit

Construction guideline

TECHNICAL SPECIFICATIONS FOR CROSS LINKED POLYETHYLENE INSULATED 3 CORE llkv CABLES

Armoured Instrumentation Cables to BS7917

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

P.V.C. INSULATED UNARMOURED COPPER CABLES

KEMA INSPECTION REPORT

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

Termco Heatshrink.

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton

3M Cold Shrink Joint, SC145-II/SS145-II

DATA SHEET Single Core 2HR Fire Rated Cable

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

DEVELOPMENT OF HIGH VOLTAGE EXTRUDED CABLES: THE ITALIAN EXPERIENCE

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

Instrumentation Cables

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

XLPE CABLE (11KV - Aluminium)

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

Accreditation No: LAB 041. Electrical Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan.

Test Report No.: Page 2 of 35

Instrumentation and Thermocouple Cables

Instrumentation and Thermocouple Cables

YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC

6A V CVQ cable (C rank)

3 MODIFICATIONS TO EXISTING STANDARDS

Copper Cable Company Limited

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

GEMSCAB INDUSTRIES LIMITED STANDARD PLAN FOR HT XLPE CABLES AS PER IS:7098(PART-II)

Rayfit The advanced heat-shrinkable joint sleeve for medium voltage joints up to 36 kv NEW ENERGY DIVISION

OFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable

SPECIFICATIONS FOR Gas-to-Cable termination

NPS/002/023 Technical Specification for 132kV Power Cables.

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS

THE PERFORMANCE OF XLPE WATER TREE RESISTANT INSULATION SYSTEMS AGAINST THE REQUIREMENTS OF DIN VDE /A3

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

NEMA Standards Publication No. WC ICEA Publication No. S

Technical Specification for Single Core 19/33kV Copper / TR-XLPE Underground Cable

Title Cables for Railway Signalling Applications - Traction Return Bonding and Track Connection Cables

SafeX110 Single Core Flexible Tinned Copper Cable

Data Sheet 110kV TP123-II Porcelain Insulator Outdoor Termination

H-FLEX CABLES 10/2017

*** Supercedes: BECO E and COM , , & ***

7. EXTENSION LEADS AND COMPENSATING CABLE

WIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES

(DESCO) DRAFT TENDER DOCUMENT FOR

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

MEDIUM VOLTAGE CABLES TO IEC60502, BS6622, VDE0276

TECHNICAL SPECIFICATIONS OF 66 KV 1C 630 SQ.MM. XLPE POWER CABLE FOR UNDER GROUND LINE

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

AN ISO 9001 : 2008 COMPANY

COMESA HARMONISED COMESA/DHS STANDARD 227-1: 2005

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

12-SDMS-01 Rev.02 SPECIFICATIONS FOR

CERTIFICATE OF ACCREDITATION

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

Technical Specification for Plastic-Insulated Low Voltage Cables

ANSI/NEMA WC ICEA S Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

15 kv EPR Insulated, Jacketed, URD Cable

Cathodic Protection Cable

SECTION 07. TECHNICAL SPECIFICATIONS OF 11 KV XLPE CU CABLE (1x500 mm 2 )

Selection of the Correct Optical Cable Outer Jacket for the Application

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

BLACK EPR INSULATED MEDIUM VOLTAGE CABLES. Ronald F. Frank, Eng. Consultant

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

NPS/002/017 Technical Specification for 66 kv and 132 kv Cable Accessories

094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA

A Deep Insight on Improvement in HV and EHV XLPE AC Cable Technology

Transcription:

XLPE MATERIAL The trend of cross-linked polyethylene insulated cables into power cables field is quite prevalent in the world as the substitutes of paper insulated cables, which had played the leading role in electric power transmission stage. Thus, nowadays after making its impact on its use in the medium voltage cable category, the stage seems to be turning in favour of XLPE cables in the high voltage and extra high voltage range. Especially in the higher voltage area, the monopoly of paper insulated cables, such as oil filled cable, gas filled and compressed type of cables, is gradually collapsing into the co-existence with XLPE cables, which have great advantages and economical reasons such as higher permissible temperature level, ease of jointing and maintenance techniques and omission of equivalent inherent to the pressurized cable. Electrical performance of XLPE is excellent. Di-electric breakdown strength and volume resistivity are high and both Di-electric loss (tan δ) and dielectric constant (ε) are low. Thermal resistivity is low. XLPE insulated cables can operate continuously at a temperature of 90ºC, because they have excellent heat ageing characteristics. This leads to large power transmission capacity. XLPE cables are lighter in weight, they are easy to handle and install and jointing and termination is also easy. They are of dry type because no oil impregnation is involved. The insulation material for XLPE cables is low-density (LD) polyethylene. PE has for a long time had a wide use as cable insulating and sheath materials owing to its excellent electrical and mechanical properties, its lightness, low temperature flexibility and good resistance to moisture, chemicals, ozone etc. as well as its comparatively low price. However, Low Density Polyethylene has properties which limit its use as cable insulation. Being a thermoplastic, its softening temperature is 05-5ºC. Another disadvantage is its tendency to stress cracking when in contact with certain surface-active agents. By means of a process reminiscent of the vulcanization of rubber, PE molecules can be cross-linked, thus greatly improving the thermal and mechanical properties of the material, while its electrical properties are retained largely unchanged. This product, cross-linked polyethylene (XLPE), is therefore no longer a thermoplastic. It assumes elastic, rubber-like consistency, a property that retains during further rise of temperature. The tendency to stress cracking entirely disappears and the material also acquires very good resistance to ageing in hot air. CROSS-LINKED POLYETHYLENE PE is made up of long molecular chains. By cross-linking, these chains a network of strong bonds is created and PE is converted into cross-linked polyethylene, XLPE.

THERMAL PROPERTIES Owing to the cross-linking, XLPE is a very heat-resistant material. It cannot melt like polyethylene but decomposes and carbonizes if exposed for long periods to temperature above 00ºC. The permissible conductor temperature during short-circuit has therefore been put at 50ºC and under continuous load, conductors with XLPE insulation may have a temperature of 90ºC. These temperature are specified by International standards. In emergency conditions and for limited period, XLPE can withstand 0ºC. XLPE, like PE, retains its low temperature flexibility down to -0ºC which implies great advantages during laying of cables. ELECTRICAL PROPERTIES The good electrical properties of PE remain largely unchanged during cross-linking process. XLPE therefore, like PE, has a very small and insignificant temperature dependant loss factor (tan δ) and dielectric constant (ε) As a result the dielectric loss of XLPE cables are small in comparison with those of PVC and paper insulated cables. XLPE cables are specially adapted for long cable routes and high voltages, in both cases where dielectric losses are of great significant. MECHANICAL PROPERTIES Polyethylene has good mechanical properties. It is interesting that at normal temperature PE can resist local stress better than PVC. In this respect XLPE has the same advantageous properties as PE and certain grades, such as filled XLPE insulation also resist abrasion much better than polyethylene. CHEMICAL PROPERTIES Owing to the cross-linking of molecules XLPE better resistance than PE to most chemical such as ordinary acids, bases and oil. ENVIRONMENTAL POLLUTION AND CABLES From the environmental aspect, both PVC and oil-impregnated paper-insulated cables have distinct disadvantages. When PVC cables burn they give off corrosive gases, and a leaking oil filled cable may cause severe damage to environment. XLPE admittedly burns, but the pro of combustion carbon dioxide and water do not cause damage. Filled XLPE used for low voltage cables can also be made resistant to flame propagation and the compound does not produce halogen.

CROSS-LINKING PROCESS Cross-linking is done by agent Di-Cumyl Peroxide (DCP). Cross-linking takes place in the CCV Tube under heated and pressurized Nitrogen where DCP decomposes into two radicals, which react with Polyethylene, thereby causing cross-linking. Peroxide is already mixed at the material supplier s plant with proper balance of anti-oxidant and peroxide to ensure the required thermal stability and optimum curing level. Therefore, no mixing is done during production. This prevents problems which might occur due to the unbalance mixing of material during production stage. Un-packing and handling of the material is also done in similar super clean environment. The mixing ratio is about to.5 PHR with very small amount of anti-oxidant. The cross-link residue is gas, which defuses out of the insulation gradually. Other residuals are Acetophone and Cumyl-alcohol which are in very low ratio. Research, in this regard, has proven that these materials have very good effect on insulation such as: a) It improves the breaking strength when inclusion occurs in XLPE material. b) It slows water tree growth in the XLPE material under service. National Cables Industry employs in-line dry curing for all its CCV lines along with state-of-the-art Triple Cross-Head extrusion where the Screen, and Screen are extruded simultaneously by means of a Triple Cross Head which has the following advantages: Reduce micro voids and moisture content in insulation and ensures enhanced and stable breakdown strength and uniform insulation structure. Ensures extremely accurate layer thickness. Ensures high purity in the frontier limit between the semi-conductive layers and the insulation. Provides optimal fusion of the individual layers without contamination. Ensures a firm bond and smooth interface between each layer improving electrical properties. Prevents unforeseen damage to the conductor or insulation screen during manufacturing process. The above are optimized by the use of an X-Ray unit located immediately after the cross-head which provides a transparent view of all three layers. This arrangement also facilitates recording the trend every seconds. The unit continuously scans 60ºC geometry of the cable and displays the maximum, minimum and eccentricity of all three layers separately. Any deviation between the specified values and the measured values are recorded and adjusted automatically. Also incorporated in the CCV line is the Twin-Rot system, one of the latest in manufacturing technology, which ensures superior control of eccentricity and eliminates the possibility of Pear Drop since the cable rotates during manufacture.

QUALITY ASPECT It is the policy of National Cables Industry to supply customers with pro meeting fully their stated needs. The pro perform their required functions safely, consistently and reliably of their intended use. They fully meet the specifications which they are designed to meet whether Customer, Country or International. NCI sources its raw materials from reputed suppliers from all over the world. The most important cable constituents such as XLPE material, conductor and insulation shielding material are procured from the world s leading suppliers of cable components. Right from the beginning, all incoming material and cable constituents are analyzed and tested to ensure their quality and compliance with specifications before being used. During manufacture, again complete tests are performed on physical, mechanical and electrical properties of insulation and sheath material. NCI pro are also type tested at International agencies. Several of the pro are type tested and certified from KEMA, Netherlands, IPH, Berlin, Germany and CPRI, India. Type tests are also performed in-house on a pre-defined regular basis to ensure and guarantee the quality of the manufactured pro. Testing facilities are equipped with up-to-date most modern and advanced laboratories. The laboratories are equipped with facilities for complete testing of its pro both for incoming raw materials as well as finished goods as per International Standards. Test fields include routine test field with large shielded enclosures for carrying out the routine high voltage tests,partial discharge measurement up to 50kV at a noise level of below pc, measurement of (tan δ),capacitance and 900kV impulse generator. 5

CCV Line MV Test Field 6

Material Testing Laboratory 7

The table below shows some typical properties of XLPE material, PVC, EP Rubber and Impregnated Paper Unfilled XLPE Filled PVC EP Rubber Impregnated Paper Dielectric constant.0 5.5 Loss factor, @ 50-60Hz, 0ºC 0.0005 0.0005 0.07 0.00 0.00 Volume resistivity, Ω.cm 0 6 0 0 0 6 0 Max. Continuous operating Temperature, ºC Max. conductor temperature at Short-circuit current ºC 90 90 70 5 65 50 50 60 50 50 Tensile Strength N/mm 5 5 5 5 - Elongation at rupture, % 500 00 50 00 - Flexibility 0 ºC -0 ºC Good Good Good Good Excellent Poor Excellent Excellent - - Abrasion resistance Good Excellent Good Poor - Deformation resistance @ 50 ºC Good Excellent Poor Excellent Good Oil resistance at 70 ºC Good Good Good Poor - Fire resistance Poor Moderate Excellent Poor Poor Ageing resistance at 00 ºC Excellent Excellent Moderate Good Good 0 ºC Good Good Poor Moderate Moderate 50 ºC Moderate Moderate - Poor Poor *Filled XLPE is used for 0.6/kV cables.

CONDUCTORS s shall be stranded class of plain annealed copper or aluminium and in accordance with IEC 60 and BS EN 60 (earlier BS 660). CONDUCTOR SCREEN screen shall be non-metallic and shall consist of an extruded semi-conductive compound which may be applied on top of a semi-conductive tape at the manufacturer s discretion. The extruded semi-conducting compound shall be firmly bonded to the insulation. XLPE INSULATION shall be XLPE (cross-linked polyethylene). and test requirements shall comply with IEC 6050- and IEC 60 series. INSULATION SCREEN The insulation screen shall consist of a non-metallic semi-conducting layer in combination with a metallic layer. Non-metallic part: The non-metallic layer shall be extruded directly upon the insulation of each core and shall consist of either a strippable or bonded semi-conducting compound. Metallic part: Metallic layer shall consist of one or more tapes or a concentric layer of wires or a combination of wire and tapes. INNER COVERING/SEPARATION SHEATH Inner covering may be extruded or lapped. When the underlying metallic layer and the armour are of different materials, they shall be separated by an extruded sheath of PVC or Polyethylene or LSF as applicable. METALLIC ARMOUR Armour shall be as per IEC 6050- of the following types: a) Round Wire Armour b) Double Tape Armour Armour material shall be Galvanized Steel for three core cables and Aluminium for single core cables. OUTER SHEATH Outer sheath shall be extruded PVC type ST as per IEC 6050-, Type 9 as per BS 7655. Special type of PVC sheathing materials such as Fire Retardant PVC, anti-termite and anti-rodent PVC, Ultraviolet PVC, Oil Resistant PVC, etc. are available on request. Also, other special sheathing materials such as LLDPE, MDPE, HDPE, LSF etc are available. PHASE IDENTIFICATION For core cables, Red, Yellow and Blue coloured strips shall be applied under the metallic screen throughout the length of the cable for phase identification. For single core cables no phase identification shall be provided. 9

UNARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.5/6(7.)kV 6 5.. Screen (Non-metallic). Screen 5. Screen (Metallic). XLPE 6. Outer Sheath of Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5.5..5 0 50 75 5 6.9.5.5..6 9 650 5 50..5.7.6.6 75 950 70 9.7.5 6..6.6 00 75 95..5.0.7.7 5 00 75 0.9.5 9.5.7. 6 6 550 750 50..5 0.9.. 7 5 00 5 6.0.5.6..9 9 0 00 00 0..6 5..9.9 00 000 00 0.. 7.6.0.0 6 00 600 00..0 0... 9 75 675 500 6.7..7.. 575 500 60 0..... 6 600 7075 ratings Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A. Km 5 0.77 0. 0.760 0.6.575 0 6 67 96 0.5 5 0.5 0.6 0.75 0.9 5.005 66 7 57 59 9 0 0.65 50 0.7 0.0 0.70 0. 7.50 96 0 6 6 0.7 70 0.6 0. 0.69 0.7 0.00 9 6 7 9 96 0 56 0.7 95 0.9 0.7 0.679 0.9.55 5 9 7 7 6 69 0.69 0 0.5 0.6 0.660 0. 7.60 0 7 6 500 0.5 50 0. 0.5 0.65 0..50 6 66 7 7 559 0.9 5 0.099 0. 0.60 0.5 6.55 06 0 7 9 5 550 67 0.67 0 0.075 0. 0.6 0.56.0 69 70 7 5 6 67 75 0. 00 0.060 0. 0.596 0.5.900 56 5 50 50 75 79 6 0.5 00 0.070 0. 0.57 0.6 57.00 590 57 56 57 5 7 9 0.0 500 0.066 0.06 0.56 0.6 7.500 655 65 65 60 956 95 0 0.099 60 0.0 0.96 0.5 0.7 90.090 7 690 7 70 095 06 5 0.09 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 0

UNARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=6/0()kV 6 5.. Screen (Non-metallic). Screen 5. Screen (Metallic). XLPE 6. Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.... 0 600 775 5 6.9. 5.... 700 75 50.. 6.5.. 50 990 70 9.7.... 6 075 00 95.. 9... 6 7 50 500 0.9.... 7 9 65 75 50...7..9 9 0 900 00 5 6.0...9.9 00 75 0.. 6..0.0 5 900 00 00 0....0. 5 7 75 700 00...6.. 0 5 650 500 6.7. 5... 500 575 60 0..... 6 65 700 Buried Direct In the ground ratings In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A. Km 5 0.77 0.60 0.770 0..575 0 6 67 96 0.9 5 0.5 0.0 0.75 0. 5.005 66 7 57 59 9 0 0.6 50 0.7 0.0 0.76 0.5 7.50 96 0 6 6 0.7 70 0.6 0.0 0.700 0.9 0.00 9 6 7 9 96 0 56 0.9 95 0.9 0. 0.6 0..55 5 9 7 7 6 69 0.70 0 0.5 0.76 0.666 0. 7.60 0 7 6 500 0. 50 0. 0.6 0.650 0.7.50 6 66 7 7 559 0.96 5 0.099 0.5 0.65 0.0 6.55 06 0 7 9 5 550 67 0.69 0 0.075 0. 0.65 0.5.0 69 70 7 5 6 67 75 0. 00 0.060 0.9 0.59 0.9.900 56 5 50 50 75 79 6 0.6 00 0.070 0. 0.50 0.55 57.00 590 57 56 57 5 7 9 0. 500 0.066 0.0 0.565 0.60 7.500 655 65 65 60 956 95 0 0.00 60 0.0 0.99 0.59 0.6 90.090 7 690 7 70 095 06 5 0.09 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

UNARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.7/5(7.5)kV 6 5.. Screen (Non-metallic). Screen 5. Screen (Metallic). XLPE 6. Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5 6.5.. 675 50 5 6.9.5 7.5.. 5 00 95 50..5.7.. 5 6 950 075 70 9.7.5 0... 6 75 00 95..5.0.. 0 5 575 0.9.5.5.9.9 0 750 50 50..5.9.9.9 05 5 5 6.0.5 6.6.0.0 5 5 65 0..5 9.0.0. 5 7 000 5 00 0..5.0.. 9 650 5 00..5... 75 00 500 6.7.5 7... 6 5575 5900 60 0..5.0..5 9 5 7075 775 ratings Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 5 0.77 0.70 0.70 0.7 0.56 0 6 67 96 0.0 5 0.5 0.75 0.9 0.5 0.7 66 7 57 59 9 0 0.6 50 0.7 0. 0.5 0.706 0. 96 0 6 6 0.77 70 0.6 0.0 0.690 0.5 0.9 9 6 7 9 96 0 56 0.5 95 0.9 0.67 0.7 0.77 0.656 5 9 7 7 6 69 0.7 0 0.5 0.9 0.66 0.6 0. 0 7 6 500 0.0 50 0. 0.5 0.6 0.5 0.0 6 66 7 7 559 0.9 5 0.099 0.605 0.9 0.7 0.55 06 0 7 9 5 550 67 0.7 0 0.075 0. 0. 0.570 0. 69 70 7 5 6 67 75 0.6 00 0.060 0.07 0.55 0.5 0.0 56 5 50 50 75 79 6 0. 00 0.070 0.6 0.77 0.5 0.7 590 57 56 57 5 7 9 0. 500 0.066 0.70 0.70 0.7 0.56 655 65 65 60 956 95 0 0.0 60 0.0 0.75 0.9 0.5 0.7 7 690 7 70 095 06 5 0.09 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

UNARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=/0()kV 6 5... Screen (Non-metallic). Screen 5. Screen (Metallic). XLPE 6. Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9 6.0 9.5.. 5 7 00 95 5 6.9 5.5 9.5.. 5 7 75 000 50. 5.5 0.7.. 7 050 50 70 9.7 5.5...9 0 75 00 95. 5.5.0.9.9 0 575 675 0.9 5.5 5.5.9.0 50 000 50. 5.5 6.9.0.0 5 50 50 5 6.0 5.5.6.0. 5 7 550 750 0. 5.5.0.. 9 50 50 00 0. 5.5.0.. 0 775 975 00. 5.5 5... 650 95 500 6.7 5.5 9... 9 9 500 600 60 0. 5.5.0.5.5 5 5 750 755 ratings Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A. Km 5 0.77 0.97 0.79 0..575 0 6 67 96 0.5 5 0.5 0.6 0.76 0.6 5.005 66 7 57 59 9 0 0.6 50 0.7 0. 0.7 0. 7.50 96 0 6 6 0.0 70 0.6 0.6 0.7 0.0 0.00 9 6 7 9 96 0 56 0.5 95 0.9 0. 0.696 0..55 5 9 7 7 6 69 0.76 0 0.5 0.99 0.677 0. 7.60 0 7 6 500 0. 50 0. 0. 0.66 0.5.50 6 66 7 7 559 0.0 5 0.099 0.75 0.66 0.7 6.55 06 0 7 9 5 550 67 0.7 0 0.075 0.6 0.66 0.0.0 69 70 7 5 6 67 75 0.7 00 0.060 0.50 0.60 0..900 56 5 50 50 75 79 6 0.0 00 0.070 0.6 0.590 0.7 57.00 590 57 56 57 5 7 9 0.5 500 0.066 0.6 0.575 0.0 7.500 655 65 65 60 956 95 0 0.0 60 0.0 0.5 0.55 0.5 90.090 7 690 7 70 095 06 5 0.09 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying -0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

UNARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=/0(6)kV 6 5.. Screen (Non-metallic). Screen 5. Screen (Metallic). XLPE 6. Outer Sheath of Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 50..0 5.7.9.0 00 500 70 9.7.0 7..0.0 5 575 700 95..0 9.0. 6 7 900 000 0.9.0 0.5.. 7 50 75 50..0.9.. 0 50 675 5 6.0.0.6.. 0 900 075 0..0 6.0.. 55 700 00 0..0.0.. 5 7 50 50 00..0 0..5.5 9 50 5050 500 500 6.7.0..5.6 5 5 650 655 60 0..0.0.7.7 56 57 7650 000 Buried Direct In the ground In single -way ratings Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 50 0.7 0. 0.755 0. 7.50 96 0 6 6 0.6 70 0.6 0.57 0.7 0.6 0.00 9 6 7 9 96 0 56 0.6 95 0.9 0.6 0.7 0.7.55 5 9 7 7 6 69 0. 0 0.5 0.0 0.69 0. 7.60 0 7 6 500 0. 50 0. 0.7 0.677 0.9.50 6 66 7 7 559 0.06 5 0.099 0.0 0.66 0. 6.55 06 0 7 9 5 550 67 0.79 0 0.075 0. 0.6 0..0 69 70 7 5 6 67 75 0.5 00 0.060 0.75 0.6 0.5.900 56 5 50 50 75 79 6 0.5 00 0.070 0.60 0.60 0.7 57.00 590 57 56 57 5 7 9 0.9 500 0.066 0.9 0.59 0.0 7.500 655 65 65 60 956 95 0 0.0 60 0.0 0. 0.570 0. 90.090 7 690 7 70 095 06 5 0.09 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

ARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.5/6(7.)kV 7 6 5. 5. Screen (Metallic). Screen 6. Bedding. XLPE 7. Aluminium Wire Armour. Screen (Non-metallic). Outer Sheath Over Aluminium Wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5.5.6.. 6 75 075 5 6.9.5.5.6.. 5 7 000 75 50..5.7.6.. 7 50 50 70 9.7.5 6..6.. 0 00 600 95..5.0.6.9.9 0 750 950 0.9.5 9.5.6.9.9 975 00 50..5 0.9.6/.0.0.0 5 00 675 5 6.0.5.6.0.0.0 6 7 750 00 0..6 5..0.. 9 0 50 00 00 0.. 7.6.0.. 75 75 00..0 0..0/.5.. 5 500 575 500 6.7..7.5.5.5 50 5 6500 6900 60 0....5.6.6 5 56 050 75 ratings Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 5 0.77 0.7 0.75 0.6.575 7 6 65 9 0. 5 0.5 0.6 0.760 0.9 5.005 6 6 55 5 96 99 0.6 50 0.7 0.0 0.75 0. 7.50 9 97 6 7 0.7 70 0.6 0. 0.70 0.7 0.00 6 9 9 0.5 95 0.9 0.06 0.79 0.9.55 7 0 65 6 5 55 0 0.7 0 0.5 0.9 0.67 0. 7.60 5 0 0 06 07 55 0. 50 0. 0.0 0.65 0..50 9 0 5 60 5 50 0.99 5 0.099 0.69 0.6 0.5 6.55 9 7 76 75 5 5 559 0.7 0 0.075 0.56 0.6 0.56.0 6 6 0 5 6 59 6 0.6 00 0.060 0.6 0.60 0.5.900 95 5 7 7 69 657 697 0.9 00 0.070 0. 0.59 0.6 57.00 55 5 5 7 7 76 0. 500 0.066 0.7 0.576 0.6 7.500 59 509 57 555 7 76 5 0.0 60 0.0 0.5 0.55 0.7 90.090 66 5 6 60 975 5 0.09 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 5

ARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=6 /0()kV 7 6 5. 5. Screen (Metallic). Screen 6. Bedding. XLPE 7. Aluminium Wire Armour. Screen (Non-metallic). Outer Sheath Over Aluminium Wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9...6.. 6 7 950 00 5 6.9. 5..6.. 7 075 5 50.. 6.5.6..9 0 75 500 70 9.7...6.9.9 0 500 750 95.. 9..6.9.0 50 050 0.9...6/.0.0.0 5 50 50 50...7.0. 6 7 575 5 5 6.0...0.. 7 9 95 5 0.. 6..0.. 0 65 95 00 0....0.. 50 575 00...6.0/.5.. 5 575 5775 500 6.7. 5..5.5.5 50 5 655 6950 60 0....5.6.7 5 57 050 575 ratings Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A. Km 5 0.77 0. 0.790 0..575 7 6 65 9 0. 5 0.5 0.7 0.765 0. 5.005 6 6 55 5 96 99 0.6 50 0.7 0.50 0.79 0.5 7.50 9 97 6 7 0. 70 0.6 0. 0.7 0.9 0.00 6 9 9 0.5 95 0.9 0.6 0.697 0..55 7 0 65 6 5 55 0 0.76 0 0.5 0.0 0.67 0. 7.60 5 0 0 06 07 55 0. 50 0. 0.90 0.66 0.7.50 9 0 5 60 5 50 0.0 5 0.099 0.7 0.67 0.0 6.55 9 7 76 75 5 5 559 0.7 0 0.075 0.6 0.67 0.5.0 6 6 0 5 6 59 6 0.7 00 0.060 0.5 0.6 0.9.900 95 5 7 7 69 657 697 0.0 00 0.070 0. 0.59 0.55 57.00 55 5 5 7 7 76 0.5 500 0.066 0. 0.576 0.60 7.500 59 509 57 555 7 76 5 0.0 60 0.0 0.7 0.560 0.6 90.090 66 5 6 60 975 5 0.09 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 6

ARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.7 /5(7.5)kV 7 6 5. 5. Screen (Metallic). Screen 6. Bedding. XLPE 7. Aluminium Wire Armour. Screen (Non-metallic). Outer Sheath Over Aluminium Wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5 6.5.6..9 0 00 5 5 6.9.5 7.5.6.9.9 9 50 75 50..5.7.6.9.9 0 75 65 70 9.7.5 0..6.9.0 650 75 95..5.0.0.0. 5 6 050 00 0.9.5.5.0.. 6 50 600 50..5.9.0.. 0 675 000 5 6.0.5 6.6.0.. 0 50 50 0..5 9.0.0.. 00 5 00 0..5.0.0/.5.. 7 50 975 00..5..5.5.5 9 50 5575 6000 500 6.7.5 7..5.6.6 5 5 675 700 60 0..5.0.5.7.7 57 59 00 775 ratings Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 5 0.77 0.505 0.796 0.7.575 7 6 65 9 0.7 5 0.5 0. 0.77 0.9 5.005 6 6 55 5 96 99 0.66 50 0.7 0.6 0.75 0. 7.50 9 97 6 7 0. 70 0.6 0. 0.79 0. 0.00 6 9 9 0.57 95 0.9 0. 0.70 0.5.55 7 0 65 6 5 55 0 0.7 0 0.5 0. 0.6 0.7 7.60 5 0 0 06 07 55 0.5 50 0. 0.0 0.66 0.9.50 9 0 5 60 5 50 0.0 5 0.099 0. 0.65 0. 6.55 9 7 76 75 5 5 559 0.76 0 0.075 0.7 0.6 0.5.0 6 6 0 5 6 59 6 0.9 00 0.060 0.6 0.66 0.9.900 95 5 7 7 69 657 697 0. 00 0.070 0.6 0.596 0. 57.00 55 5 5 7 7 76 0.7 500 0.066 0.7 0.5 0. 7.500 59 509 57 555 7 76 5 0.05 60 0.0 0.5 0.565 0.5 90.090 66 5 6 60 975 5 0.095 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 7

ARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)= /0()kV 7 6 5.. 5. Screen (Metallic). Screen 6. Bedding. XLPE 7. Aluminium Wire Armour. Screen (Non-metallic). Outer Sheath Over Aluminium Wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9 6.0 9.5.6.9.0 00 55 5 6.9 5.5 9.5.6.9.0 75 600 50. 5.5 0.7.6.0.0 5 550 5 70 9.7 5.5..0.0. 5 7 50 00 95. 5.5.0.0.. 7 00 75 0.9 5.5 5.5.0.. 0 550 00 50. 5.5 6.9.0.. 0 900 75 5 6.0 5.5.6.0.. 75 650 0. 5.5.0.0/.5.. 7 975 500 00 0. 5.5.0.5..5 9 5 575 00. 5.5 5..5.5.6 5 5 575 650 500 6.7 5.5 9..5.6.7 55 57 7000 7500 60 0. 5.5.0.5.. 59 6 550 9050 ratings Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 5 0.77 0.50 0.05 0..575 7 6 65 9 0. 5 0.5 0.96 0.776 0.6 5.005 6 6 55 5 96 99 0.6 50 0.7 0.7 0.75 0. 7.50 9 97 6 7 0. 70 0.6 0.5 0.7 0.0 0.00 6 9 9 0.59 95 0.9 0. 0.70 0..55 7 0 65 6 5 55 0 0.0 0 0.5 0. 0.69 0. 7.60 5 0 0 06 07 55 0.7 50 0. 0.0 0.67 0.5.50 9 0 5 60 5 50 0.05 5 0.099 0.97 0.657 0.7 6.55 9 7 76 75 5 5 559 0.7 0 0.075 0.9 0.67 0.0.0 6 6 0 5 6 59 6 0.5 00 0.060 0.70 0.6 0..900 95 5 7 7 69 657 697 0. 00 0.070 0.5 0.60 0.7 57.00 55 5 5 7 7 76 0. 500 0.066 0.55 0.56 0.0 7.500 59 509 57 555 7 76 5 0.06 60 0.0 0. 0.569 0.5 90.090 66 5 6 60 975 5 0.097 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

ARMOURED SINGLE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=/0(6) kv 7 6 5. 5. Screen (Metallic). Screen 6. Bedding. XLPE 7. Aluminium Wire Armour. Screen (Non-metallic). Outer Sheath Over Aluminium Wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 50..0 5.7.0.. 9 0 05 50 70 9.7.0 7..0.. 0 00 575 95..0 9.0.0.. 675 900 0.9.0 0.5.0/.5.. 6 950 5 50..0.9.5..5 7 500 50 5 6.0.0.6.5.5.5 9 50 95 00 0..0 6.0.5.5.6 5 5 600 505 00 0..0.0.5.6.7 5 55 575 575 00..0 0..5.7. 57 59 650 650 500 6.7.0..5..9 6 6 7600 00 60 0..0.0.5.9.0 65 67 900 9700 ratings Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 50 0.7 0.50 0.766 0. 7.50 9 97 6 7 0.90 70 0.6 0. 0.70 0.6 0.00 6 9 9 0.6 95 0.9 0.67 0.7 0.7.55 7 0 65 6 5 55 0 0.6 0 0.5 0.50 0.70 0. 7.60 5 0 0 06 07 55 0. 50 0. 0.7 0.6 0.9.50 9 0 5 60 5 50 0. 5 0.099 0. 0.67 0. 6.55 9 7 76 75 5 5 559 0. 0 0.075 0.07 0.65 0..0 6 6 0 5 6 59 6 0.56 00 0.060 0.9 0.65 0.5.900 95 5 7 7 69 657 697 0. 00 0.070 0.77 0.6 0.7 57.00 55 5 5 7 7 76 0. 500 0.066 0.66 0.599 0.0 7.500 59 509 57 555 7 76 5 0. 60 0.0 0.57 0.5 0. 90.090 66 5 6 60 975 5 0.0 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 9

UNARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.5/6(7.)kV 7 6 5. 5. Screen (Metallic). Screen 6. PP Filler. XLPE 7. Bedding. Screen (Non-metallic). Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5.5.. 9 95 075 5 6.9.5.5.. 00 50 50..5.7.. 7 775 950 70 9.7.5 6... 5 550 700 95..5..5.5 5 55 500 600 0.9.5 9.5.6.6 56 59 550 575 50..5 0.9.7. 59 6 650 6550 5 6.0.5.6..9 6 66 7550 775 0..6 5..0.0 69 7 9500 9675 00 0.. 7.6.. 75 7 650 75 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0.05 0.6.575 9 0.799 5 0.5 0.9 0.9 5.005 5 70 0.590 50 0.7 0. 0. 7.50 5 0 0. 70 0.6 0.7 0.6 0.00 9 5 0.5 95 0.9 0.66 0.9.55 6 0 0. 0 0.5 0.59 0. 7.60 9 6 5 0.06 50 0. 0.5 0.7.50 97 9 0.75 5 0.099 0.50 0.5 6.55 77 6 55 0.50 0 0.075 0. 0.56.0 90 5 0.5 00 0.060 0.6 0.5.900 9 606 0.0 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 0

UNARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=6/0()kV 7 6 5. 5. Screen (Metallic). Screen 6. PP Filler. XLPE 7. Bedding. Screen (Non-metallic). Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.... 6 5 00 5 6.9. 5... 6 575 750 50.. 6.5.. 5 050 50 70 9.7...5.5 5 55 5 000 95.. 9..6.7 56 59 750 5000 0.9...7. 60 6 5675 550 50...7..9 6 65 665 675 5 6.0...9.0 67 70 775 50 0.. 6... 7 76 9900 05 00 0..... 7 975 00 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0. 0..575 9 0.0 5 0.5 0. 0. 5.005 5 70 0.595 50 0.7 0.05 0.5 7.50 5 0 0.5 70 0.6 0.9 0.9 0.00 9 5 0.9 95 0.9 0.5 0..55 6 0 0.5 0 0.5 0.76 0. 7.60 9 6 5 0.09 50 0. 0.69 0.7.50 97 9 0.79 5 0.099 0.6 0.0 6.55 77 6 55 0.5 0 0.075 0.55 0..0 90 5 0.7 00 0.060 0. 0..900 9 606 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

UNARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.7/5(7.5)kV 7 6 5. 5. Screen (Metallic). Screen 6. PP Filler. XLPE 7. Bedding. Screen (Non-metallic). Outer Sheath size Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5 6.5.. 7 50 550 700 5 6.9.5 7.5.5.5 5 5 950 5 50..5.7.6.6 5 56 50 600 70 9.7.5 0..7.7 5 6 00 50 95..5.0.. 6 6 575 55 0.9.5.5.9.9 65 6 650 600 50..5.9.0. 66 7 75 700 5 6.0.5 6.6.. 7 76 500 00 0..5 9.0.. 7 0550 0775 00 0..5.0..5 6 550 00 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0.59 0.7.575 9 0.09 5 0.5 0. 0.9 5.005 5 70 0.600 50 0.7 0.9 0. 7.50 5 0 0.57 70 0.6 0. 0. 0.00 9 5 0. 95 0.9 0.06 0.5.55 6 0 0.55 0 0.5 0.96 0.7 7.60 9 6 5 0. 50 0. 0. 0.9.50 97 9 0. 5 0.099 0.0 0. 6.55 77 6 55 0.55 0 0.075 0.7 0.5.0 90 5 0.0 00 0.060 0.60 0.9.900 9 606 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

UNARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=/0()kV 7 6 5. 5. Screen (Metallic). Screen 6. PP Filler. XLPE 7. Bedding. Screen (Non-metallic). Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9 6.0 9.5.6.6 55 59 075 75 5 6.9 5.5 9.5.6.7 55 59 900 550 50. 5.5 0.7.7. 5 6 000 00 70 9.7 5.5...9 6 65 75 900 95. 5.5.0.9.0 66 69 5700 6000 0.9 5.5 5.5.0. 70 7 6700 6900 50. 5.5 6.9.. 7 76 7775 000 5 6.0 5.5.6.. 7 0 900 95 0. 5.5.0..5 6 00 00 00 0. 5.5.0.6.6 90 50 50 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0.9 0..575 9 0.6 5 0.5 0.65 0.6 5.005 5 70 0.60 50 0.7 0.9 0. 7.50 5 0 0.6 70 0.6 0. 0.0 0.00 9 5 0.6 95 0.9 0. 0..55 6 0 0.5 0 0.5 0. 0. 7.60 9 6 5 0.6 50 0. 0.0 0.5.50 97 9 0.5 5 0.099 0.95 0.7 6.55 77 6 55 0.5 0 0.075 0.5 0.0.0 90 5 0. 00 0.060 0.70 0..900 9 606 0.5 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

UNARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=/0(6)kV 7 6 5. 5. Screen (Metallic). Screen 6. PP Filler. XLPE 7. Bedding. Screen (Non-metallic). Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 50..0 5.7.. 7 7 500 550 70 9.7.0 7... 75 77 600 600 95..0 9.0.. 7 750 700 0.9.0 0.5..5 5 00 00 50..0.9.5.6 5 950 900 5 6.0.0.6.6.7 9 9 0500 0750 0..0 6.0..9 95 9 600 950 00 0..0.0.0.0 00 0 900 5050 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 50 0.7 0.99 0. 7.50 5 0 0.7 70 0.6 0.0 0.6 0.00 9 5 0.5 95 0.9 0.69 0.7.55 6 0 0.67 0 0.5 0.55 0. 7.60 9 6 5 0. 50 0. 0.5 0.9.50 97 9 0.9 5 0.099 0. 0. 6.55 77 6 55 0.66 0 0.075 0. 0..0 90 5 0. 00 0.060 0.0 0.5.900 9 606 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.5/6(7.) kv 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Wire Armour. Screen (Non-metallic) 9. Outer Sheath 5. Screen (Metallic) Over steel wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5.5.0.. 6 00 675 5 6.9.5.5.0/.5.. 5 50 750 75 50..5.7.5.5.5 9 5 775 500 70 9.7.5 6..5.6.6 5 56 575 6000 95..5.0.5.7. 57 60 600 750 0.9.5 9.5.5..9 6 6 750 50 50..5 0.9.5.9.0 6 67 900 950 5 6.0.5.6.5.. 6 7 075 0750 0..6 5..5/.5.. 7 7 600 950 00 0.. 7.6.5.5.6 5 6050 675 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0.6 0.6.575 9 0. 5 0.5 0. 0.9 5.005 5 7 0.60 50 0.7 0. 0. 7.50 5 05 0.5 70 0.6 0. 0.6 0.00 0 9 5 0. 95 0.9 0.6 0.9.55 6 07 0.57 0 0.5 0.09 0. 7.60 9 6 5 0.5 50 0. 0.0 0.7.50 96 97 0.5 5 0.099 0.00 0.5 6.55 7 5 5 0.59 0 0.075 0.9 0.56.0 7 59 0. 00 0.060 0.6 0.5.900 5 599 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 5

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=6/0()kV 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Wire Armour. Screen (Non-metallic) 9. Outer Sheath 5. Screen (Metallic) Over steel wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9...5..5 5 50 50 5 6.9. 5..5.5.6 5 5 65 5000 50.. 6.5.5.6.7 5 57 500 565 70 9.7...5.7. 57 6 600 6575 95.. 9..5.9.9 6 65 75 7700 0.9...5.0.0 65 6 75 750 50...7.5.. 6 7 9550 9975 5 6.0...5.. 7 76 000 5 0.. 6..5..5 0 00 775 00 0....5.6.6 5 665 7050 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0.7 0..575 9 0.5 5 0.5 0.6 0. 5.005 5 7 0.60 50 0.7 0.55 0.5 7.50 5 05 0.6 70 0.6 0. 0.9 0.00 0 9 5 0. 95 0.9 0.5 0..55 6 07 0.6 0 0.5 0.6 0. 7.60 9 6 5 0. 50 0. 0.9 0.7.50 96 97 0. 5 0.099 0. 0.0 6.55 7 5 5 0.6 0 0.075 0.05 0..0 7 59 0.7 00 0.060 0.97 0..900 5 599 0.0 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 6

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.7/5(7.5)kV 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Wire Armour. Screen (Non-metallic) 9. Outer Sheath 5. Screen (Metallic) Over of steel wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5 6.5.5.6.6 5 56 00 5075 5 6.9.5 7.5.5.7.7 56 59 500 5575 50..5.7.5.. 59 6 5950 600 70 9.7.5 0..5.9.0 6 66 695 700 95..5.0.5.0. 67 70 00 5 0.9.5.5.5.. 70 7 975 955 50..5.9.5/.5.. 75 7 05 65 5 6.0.5 6.6.5..5 0 900 00 0..5 9.0.5.6.7 6 9 55 565 00 0..5.0.5.7. 9 9 755 7975 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0. 0.7.575 9 0.0 5 0.5 0.9 0.9 5.005 5 7 0.609 50 0.7 0.79 0. 7.50 5 05 0.66 70 0.6 0.6 0. 0.00 0 9 5 0. 95 0.9 0.56 0.5.55 6 07 0.65 0 0.5 0.6 0.7 7.60 9 6 5 0. 50 0. 0. 0.9.50 96 97 0.9 5 0.099 0.0 0. 6.55 7 5 5 0.65 0 0.075 0. 0.5.0 7 59 0.0 00 0.060 0. 0.9.900 5 599 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 7

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=/0()kV 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Wire Armour. Screen (Non-metallic) 9. Outer Sheath 5. Screen (Metallic) SIZE Over steel wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9 6.0 9.5.5..9 6 6 5675 5975 5 6.9 5.5 9.5.5..9 6 6 5900 600 50. 5.5 0.7.5.0 6 67 6600 695 70 9.7 5.5..5.. 6 7 7600 795 95. 5.5.0.5.. 7 75 50 900 0.9 5.5 5.5.5.. 77 075 00 50. 5.5 6.9.5..5 00 600 5 6.0 5.5.6.5.6.6 5 775 5 0. 5.5.0.5.7. 9 9 6050 655 00 0. 5.5.0.5.9.0 95 99 00 900 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0. 0..575 9 0.5 5 0.5 0.5 0.6 5.005 5 7 0.6 50 0.7 0.99 0. 7.50 5 05 0.7 70 0.6 0. 0.0 0.00 0 9 5 0.6 95 0.9 0.7 0..55 6 07 0.6 0 0.5 0.6 0. 7.60 9 6 5 0.5 50 0. 0.5 0.5.50 96 97 0.9 5 0.099 0.5 0.7 6.55 7 5 5 0.67 0 0.075 0.5 0.0.0 7 59 0. 00 0.060 0.0 0..900 5 599 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=/0(6) kv 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Wire Armour. Screen (Non-metallic) 9. Outer Sheath 5. Screen (Metallic) Over steel Wire Outer Sheath Overall CUT/CUW CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 50..0 5.7.5.. 7 900 975 70 9.7.0 7..5.5.5 5 075 050 95..0 9.0.5.6.7 6 9 775 50 0.9.0 0.5.5.7. 90 9 000 75 50..0.9.5..9 9 96 50 750 5 6.0.0.6.5.0.0 97 00 5975 65 0..0 6.0.5.. 0 06 75 50 00 0..0.0.5.. 0 095 00 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 50 0.7 0.9 0. 7.50 5 05 0.0 70 0.6 0.0 0.6 0.00 0 9 5 0.55 95 0.9 0.9 0.7.55 6 07 0.77 0 0.5 0.05 0. 7.60 9 6 5 0. 50 0. 0.95 0.9.50 96 97 0.0 5 0.099 0. 0. 6.55 7 5 5 0.75 0 0.075 0.7 0..0 7 59 0.9 00 0.060 0.5 0.5.900 5 599 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 9

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.5/6(7.) kv 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Tape Armour. Screen (Non-Metallic) 9. Outer Sheath 5. Screen (Metallic) Over Number & of steel Tape Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5.5 x0.5.. 500 700 5 6.9.5.5 x0.5.. 6 900 50 50..5.7 x0.5.. 6 9 50 650 70 9.7.5 6. x0.5.5.5 50 5 75 500 95..5.0 x0.5.6.6 5 57 550 5500 0.9.5 9.5 x0.5.7. 5 6 675 600 50..5 0.9 x0.5..9 6 6 750 7500 5 6.0.5.6 x0.5.9.0 65 6 75 775 0..6 5. x0.5.. 7 7 0550 0900 00 0.. 7.6 x0.5.. 77 0 75 75 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0.6 0.6.575 9 0.0 5 0.5 0. 0.9 5.005 5 7 0.600 50 0.7 0. 0. 7.50 5 05 0.5 70 0.6 0. 0.6 0.00 0 9 5 0. 95 0.9 0.6 0.9.55 6 07 0.57 0 0.5 0.09 0. 7.60 9 6 5 0.5 50 0. 0.0 0.7.50 96 97 0.5 5 0.099 0.00 0.5 6.55 7 5 5 0.59 0 0.075 0.9 0.56.0 7 59 0. 00 0.060 0.6 0.5.900 5 599 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 0

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=6/0() kv 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Tape Armour. Screen (Non-Metallic) 9. Outer Sheath 5. Screen (Metallic) Over Number & of steel Tape Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.. x0.5.. 5 5 00 5 6.9. 5. x0.5..5 5 75 55 50.. 6.5 x0.5.5.6 50 5 5 050 70 9.7.. x0.5.6.7 5 5 650 950 95.. 9. x0.5.7. 5 6 5675 5900 0.9.. x0.5.9.9 6 65 6650 650 50...7 x0.5.0.0 65 6 7650 7975 5 6.0.. x0.5.. 69 7 9000 900 0.. 6. x0.5.. 76 7 00 50 00 0... x0.5..5 0 00 575 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0.7 0..575 9 0.5 5 0.5 0.6 0. 5.005 5 7 0.60 50 0.7 0.55 0.5 7.50 5 05 0.6 70 0.6 0. 0.9 0.00 0 9 5 0. 95 0.9 0.55 0..55 6 07 0.65 0 0.5 0.6 0. 7.60 9 6 5 0. 50 0. 0.9 0.7.50 96 97 0. 5 0.099 0. 0.0 6.55 7 5 5 0.6 0 0.075 0.0 0..0 7 59 0.7 00 0.060 0.97 0..900 5 599 0.0 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=.7/5(7.5) kv 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Tape Armour. Screen (Non-Metallic) 9. Outer Sheath Over Number & of steel Tape Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9.5 6.5 x0.5.5.5 50 5 00 500 5 6.9.5 7.5 x0.5.6.6 5 56 750 000 50..5.7 x0.5.7.7 56 59 5 55 70 9.7.5 0. x0.5.. 60 6 500 55 95..5.0 x0.5.9.0 6 67 650 6550 0.9.5.5 x0.5.0. 67 70 75 7500 50..5.9 x0.5.. 70 7 50 650 5 6.0.5 6.6 x0.5.. 75 7 900 050 0..5 9.0 x0.5..5 900 00 00 0..5.0 x0..6.7 7 90 00 550 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0. 0.7.575 9 0.0 5 0.5 0.9 0.9 5.005 5 7 0.609 50 0.7 0.79 0. 7.50 5 05 0.6 70 0.6 0.6 0. 0.00 0 9 5 0. 95 0.9 0.56 0.5.55 6 07 0.65 0 0.5 0.6 0.7 7.60 9 6 5 0. 50 0. 0. 0.9.50 96 97 0.9 5 0.099 0.0 0. 6.55 7 5 5 0.65 0 0.075 0. 0.5.0 7 59 0.0 00 0.060 0. 0.9.900 5 599 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=/0() kv 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Tape Armour. Screen (Non-Metallic) 9. Outer Sheath 5. Screen (Metallic) Over Number & of steeltape Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 5.9 6.0 9.5 x0.5.7. 5 6 000 5 5 6.9 5.5 9.5 x0.5.7. 5 6 5 500 50. 5.5 0.7 x0.5..9 6 6 5 5050 70 9.7 5.5. x0.5.0 6 67 500 595 95. 5.5.0 x0.5.. 69 7 65 7000 0.9 5.5 5.5 x0.5.. 66 75 7900 00 50. 5.5 6.9 x0.5.. 76 79 9000 900 5 6.0 5.5.6 x0.5..5 0 000 0700 0. 5.5.0 x0.5.6.7 7 90 00 700 00 0. 5.5.0 x0...9 9 95 5600 5900 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 5 0.77 0. 0..575 9 0.5 5 0.5 0.5 0.6 5.005 5 7 0.6 50 0.7 0.99 0. 7.50 5 05 0.7 70 0.6 0. 0.0 0.00 0 9 5 0.6 95 0.9 0.7 0..55 6 07 0.6 0 0.5 0.6 0. 7.60 9 6 5 0.5 50 0. 0.5 0.5.50 96 97 0.9 5 0.099 0.5 0.7 6.55 7 5 5 0.67 0 0.075 0.5 0.0.0 7 59 0. 00 0.060 0.0 0..900 5 599 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

ARMOURED THREE CORE CABLES COPPER CONDUCTORS IEC 6050- Uo/U (Um)=/0(6) kv 9 7 6 5. 6. PP Filler. Screen 7. Bedding. XLPE. Steel Tape Armour. Screen (Non-Metallic) 9. Outer Sheath 5. Screen (Metallic) Over Number & of steel Tape Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 50..0 5.7 x0.5.. 7 76 600 6500 70 9.7.0 7. x0.5.. 77 0 700 7550 95..0 9.0 x0.5.5.5 500 650 0.9.0 0.5 x0.5.6.7 6 9 05 0600 50..0.9 x0.5.7. 9 9 50 50 5 6.0.0.6 x0..9.9 9 96 050 5 0..0 6.0 x0..0. 99 0 500 5600 00 0..0.0 x0... 0 06 7650 7900 Buried Direct In the ground ratings In buried Voltage drop Per phase mm² Ohm/km mh/km µf/km ka Amps Amps Amps V/A.Km 50 0.7 0.9 0. 7.50 5 05 0.0 70 0.6 0.0 0.6 0.00 0 9 5 0.55 95 0.9 0.9 0.7.55 6 07 0.77 0 0.5 0.05 0. 7.60 9 6 5 0. 50 0. 0.95 0.9.50 96 97 0.0 5 0.099 0. 0. 6.55 7 5 5 0.75 0 0.075 0.7 0..0 7 59 0.9 00 0.060 0.5 0.5.900 5 599 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.

UNARMOURED SINGLE CORE CABLES ALUMINIUM CONDUCTORS IEC 6050- Uo/U (Um)=.5/6(7.)kV 6 5.. Screen (Non-metallic). Screen 5. Screen (Metallic). XLPE 6. Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 6.0.5.6.. 0 75 550 5 7..5.7.. 9 5 550 50..5.9.. 500 675 70 9.7.5 6... 600 750 95.55.5.5.. 6 700 50 0.95.5 9.55.. 6 7 00 95 50..5 0.9.. 7 9 95 5 5 5.9.5.5..9 9 0 050 75 0..6 5..9.9 00 500 00 0.5. 7.7.0.0 6 550 750 00.0.0.6.. 0 95 50 500 7.0. 5.0.. 50 675 60 0..... 6 900 00 ratings SIZE Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 5.0 0. 0.760 0.6.60 0 0 0 7 0 5. 5 0.6 0.6 0.75 0.9.0 9 5 57 5 0.97 50 0.6 0. 0.76 0..70 5 57 6 9 0.75 70 0. 0. 0.69 0.7 6.60 6 9 76 7 0 6 7 0.5 95 0.0 0.7 0.679 0.9.96 9 0 0 7 0.00 0 0.5 0.6 0.660 0.. 5 60 0 9 0. 50 0.06 0.5 0.65 0..60 67 7 6 76 0 0.79 5 0.6 0. 0.60 0.5 7.6 7 0 07 50 0. 0 0.5 0. 0.6 0.56.656 67 7 5 56 50 5 59 0.9 00 0.00 0. 0.596 0.5.0 9 97 0 577 56 677 0.65 00 0.077 0. 0.57 0.6 7.760 70 66 5 57 67 676 769 0. 500 0.0605 0.06 0.56 0.6 7.00 5 59 5 5 770 767 57 0. 60 0.069 0.96 0.5 0.7 59.7 599 5 5 590 96 5 90 0.07 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 5

UNARMOURED SINGLE CORE CABLES ALUMINIUM CONDUCTORS IEC 6050- Uo/U (Um)=6/0()kV 6 5.. Screen (Non-metallic). Screen 5. Screen (Metallic). XLPE 6. Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 6.0.... 0 50 65 5 7.. 5.5.. 500 650 50.. 6.7.. 575 700 70 9.7.... 6 675 00 95.55. 9.95.. 6 00 900 0.95..5.. 9 900 000 50...7..9 9 000 00 5 5.9...9.9 50 50 0.. 6..0.0 5 00 600 00 0.5..9.0. 5 7 65 50 00.0.... 9 975 00 500 7.0. 5... 75 700 60 0..... 6 75 50 ratings SIZE Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 5.0 0.60 0.770 0..60 0 0 0 7 0 5. 5 0.6 0.0 0.75 0. 0.0 9 5 57 5 0.97 50 0.6 0. 0.7 0.5.70 5 57 6 9 0.77 70 0. 0.0 0.700 0.9 6.60 6 9 76 7 0 6 7 0.50 95 0.0 0. 0.6 0..96 9 0 0 7 0.0 0 0.5 0.76 0.666 0.. 5 60 0 9 0. 50 0.06 0.6 0.650 0.7.60 67 7 6 76 0 0.0 5 0.6 0.5 0.65 0.0 7.6 7 0 07 50 0.6 0 0.5 0. 0.65 0.5.656 67 7 5 56 50 5 59 0.9 00 0.00 0.9 0.599 0.9.0 9 97 0 577 56 677 0.66 00 0.077 0. 0.50 0.55 7.760 70 66 5 57 67 676 769 0. 500 0.0605 0.0 0.565 0.60 7.00 5 59 5 5 770 767 57 0. 60 0.069 0.99 0.59 0.6 59.7 599 5 5 590 96 5 90 0.0 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 6

UNARMOURED SINGLE CORE CABLES ALUMINIUM CONDUCTORS IEC 6050- Uo/U (Um)=.7/5(7.5)kV 6 5.. Screen (Non-metallic). Screen 5. Screen (Metallic). XLPE 6. Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 6.0.5 6.6.. 55 650 5 7..5 7.7.. 5 600 75 50..5.9.. 5 6 675 00 70 9.7.5 0... 7 775 75 95.55.5.5.. 0 900 000 0.95.5.55.9.9 0 05 5 50..5.9.9.9 50 5 5 5.9.5 6.5.0.0 00 500 0..5 9.0.0. 6 7 550 750 00 0.5.5... 9 775 975 00.0.5.6.. 50 50 500 7.0.5 7.6.. 5 7 550 50 60 0..5.0..5 9 5 5 50 SIZE Buried Direct In the ground ratings In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 5.0 0.70 0.70 0.7.60 0 0 0 7 0 5.0 5 0.6 0.56 0.75 0.9 0.0 9 5 57 5 0.976 50 0.6 0.0 0.7 0.0.70 5 57 6 9 0.7 70 0. 0.5 0.706 0. 6.60 6 9 76 7 0 6 7 0.5 95 0.0 0.0 0.690 0.5.96 9 0 0 7 0.0 0 0.5 0.9 0.67 0.7. 5 60 0 9 0. 50 0.06 0.77 0.656 0.9.60 67 7 6 76 0 0. 5 0.6 0.66 0.6 0. 7.6 7 0 07 50 0. 0 0.5 0.5 0.6 0.5.656 67 7 5 56 50 5 59 0.96 00 0.00 0.0 0.605 0.9.0 9 97 0 577 56 677 0.6 00 0.077 0.7 0.55 0. 7.760 70 66 5 57 67 676 769 0. 500 0.0605 0. 0.570 0. 7.00 5 59 5 5 770 767 57 0.5 60 0.069 0.07 0.55 0.5 59.7 599 5 5 590 96 5 90 0.09 Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W. 7

UNARMOURED SINGLE CORE CABLES ALUMINIUM CONDUCTORS IEC 6050- Uo/U (Um)=/0()kV 6 5.. Screen (Non-metallic). Screen 5. Screen (Metallic). XLPE 6. Outer Sheath Over Outer Sheath Overall CUT CUW CUT CUW CUT CUW mm² mm mm mm mm mm mm mm Kg/km Kg/km 5 6.0 6.0 9.6.. 6 7 675 775 5 7. 5.5 9.7.. 6 7 700 00 50. 5.5 0.9.. 7 9 775 75 70 9.7 5.5...9 9 0 75 000 95.55 5.5.5.9.9 05 5 0.95 5.5 5.55.9.0 5 50 50. 5.5 6.9.0.0 5 50 50 5 5.9 5.5.6.0. 5 7 5 65 0. 5.5.0.. 9 675 75 00 0.5 5.5... 0 95 5 00.0 5.5 6.6.. 6 00 600 500 7.0 5.5 9.6.. 7 9 00 050 60 0. 5.5.0.5.5 5 5 5 600 ratings SIZE Buried Direct In the ground In single -way Voltage drop per phase mm² Ohm/km mh/km mh/km µf/km ka Amps Amps Amps Amps Amps Amps Amps V/A.Km 5.0 0.97 0.79 0..60 0 0 0 7 0 5. 5 0.6 0.6 0.76 0.6 0.0 9 5 57 5 0.976 50 0.6 0.5 0.7 0..70 5 57 6 9 0.7 70 0. 0.6 0.7 0.0 6.60 6 9 76 7 0 6 7 0.55 95 0.0 0. 0.696 0..96 9 0 0 7 0.07 0 0.5 0.99 0.677 0.. 5 60 0 9 0.5 50 0.06 0. 0.66 0.5.60 67 7 6 76 0 0.5 5 0.6 0.75 0.66 0.7 7.6 7 0 07 50 0. 0 0.5 0.6 0.66 0.0.656 67 7 5 56 50 5 59 0.97 00 0.00 0.50 0.60 0..0 9 97 0 577 56 677 0.7 00 0.077 0.6 0.590 0.7 7.760 70 66 5 57 67 676 769 0.6 500 0.0605 0.6 0.575 0.0 7.00 5 59 5 5 770 767 57 0.6 60 0.069 0.5 0.55 0.5 59.7 599 5 5 590 96 5 90 0. Laying condition: Maximum conductor temperature 90ºC, Ambient temperature 0ºC. Underground temperature of soil 0ºC, Depth of laying - 0.m. Ground thermal resistivity.5 K.m/W, thermal resisitivity of earthenware. K.m/W.