SPECTRASHIELD. Total System for Large Wastewater Structures PART I - GENERAL

Similar documents
SPECTRASHIELD. Total System for Manholes (Brick/Concrete)

B. The condition of the structures to receive the protective coating will be classified in accordance with the following criteria:

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

Strong-Seal Sealant Specification, a permanent method of sealing the interior of the chimney and casting in manholes and catch basins.

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

SECTION SUBSURFACE PREPARATION FOR FLOOR FINISHES

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

CITY OF TAMPA ADDENDUM NO. 1. DATE: September 15, Contract 11-C-00001; Wastewater Sewer Rehabilitation by Cured-in-Place Pipe (C.I.P.P.

TECHNICAL SPECIFICATION FOR CURED-IN-PLACE MANHOLE REHABILITATION LINER SYSTEM

Florock Seamless Flooring Systems

Process Specification. Structural Rehabilitation & Corrosion Protection for Circular Structures in Wastewater Collection and Potable Water Systems

Florock Seamless Flooring Systems

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

TECHNICAL SPECIFICATIONS FOR MANHOLE REHABILITATION

Florock Seamless Flooring Systems

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

Decorative Quartz Floor Coating System

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

Hydrophilic Polyurethane Grout

SECTION 806 MANHOLE REHABILITATION

1/16 Single Broadcast Polymer Flooring System

Hydrophilic Polyurethane Grout Cartridge Application

SECTION RESINOUS FLOORING PLEXIQUARTZ BROADCAST SKID-RESISTANT QUARTZ SYSTEM

Pacific Polymers Elasto-Deck 5000MR Guide Specification

SECTION CORROSION PROTECTION FOR CONCRETE STRUCTURES

SECTION IRRIGATION PIPELINE LINING (CURED-IN-PLACE PIPE)

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

Florock Seamless Flooring Systems

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

GUIDE SPECIFICATION SECTION 07576

DIVISION 3 - CONCRETE Section Concrete Toppings Concrete Resurfacing Concrete Rehabilitation

Broadcast Parking Garage System

SECTION RESINOUS FLOORING

A. This Section includes resinous flooring systems with epoxy body coat(s).

DIVISION 7 THERMAL AND MOISTURE PROTECTION Section Traffic Coatings

Section Fluid Applied Waterproofing

DECOCOLOR FLOORING SYSTEM

DIVISION 3 -CONCRETE Section Concrete Rehabilitation Epoxy-Injected Crack Repair

SECTION XXXXX CHEMICAL GROUTING

Concrete and H2S Gas in Wet Wells and Tanks. James Orr - Project Manager NACE Inspector - Dixon Engineering

FIVE STAR PRODUCTS, INC (in the US) (outside US)

Application Guidelines for PPC Coatings Flooring

CS-75 Water-Based Adhesive Surface Primer

URETHANE. CONCRETE ROOF WATERPROOFING SYSTEM Sample Design Guideline

SECTION ELASTOMERIC LIQUID FLOORING

Caltrans G Bonded Joint Seals

STANDARD SPECIFICATIONS FOR CONSTRUCTING SANITARY SEWER FACILITIES DIVISION III - CONSTRUCTION SPECIFICATIONS SECTION 4

Fire Protection Products

DECOFLAKE DECORATIVE FLOORING SYSTEM

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

Fire Protection Products

1/8 DECORATIVE BROADCAST FLOORING SYSTEM

HIGH PERFORMANCE MIX SPECIFICATIONS

Applications (As provided by Avanti International)

Division 3 - Concrete Section Concrete Rehabilitation

FEATURES Good Toughness F/ C Cure Bonds Many Materials Excellent Durability

Municipal Infrastructure Lining and Rehabilitation

BROADCAST KITCHEN FLOORING SYSTEM

MS-2A LINER SPECIFICATIONS: for STRUCTURAL REPAIR and SEALING of MANHOLES

Pacific Polymers Elasto-Mat D&G Guide Specification

Midsun HVIC silicone is not affected by UV light, temperature, corrosive environments, or ATH pitting from dry band arcing.

Midsun HVIC silicone is not affected by UV light, temperature, corrosive environments, or ATH pitting from dry band arcing.

SPECIAL SPECIFICATION 4429 Multiple-Layer Polymer Concrete Overlay

Specifications. Specifications (Architectual) Metallic System. Metallic System

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WARRANTY ON CONCRETE SURFACE COATING

CITY OF TAMPA ADDENDUM NO. 3. DATE: February 15, 2017

Wood Floor Bonding Systems

Engine Bay Floors Floor Resurfacing 4000

Application Guidelines for PPC Coatings Swimming Pools

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant

URETHANE. Asphalt Restoration Aged BUR and Modified Bitumen Sample Design Guideline

Pacific Polymers Elasto-Deck BT Guide Specification

DIVISION 3 CONCRETE Section Concrete Rehabilitation Gravity Feed Crack Repair

Non-Shrink Grouts 5. Hydraulic Cement 6. Anchoring Cement 6. Cement Repair Mortars 7.

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant

SECTION HYDRAULIC CEMENT UNDERLAYMENT

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Products

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric Sealant

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

STRONG-SEAL GROUT 250 AND GROUT 1000 SPECIFICATIONS for Void Filling And Leak Stoppage.

DIVISION 3 -CONCRETE Section Concrete Rehabilitation Epoxy-Injected Crack Repair

REHABILITATION. Geopolymer & Hybrid Cements. > Manholes > Sewer & Storm Pipes > Other Civil Infrastructure. vortexcompanies.com

SECTION POLYURETHANE MIC COATINGS. A. Furnish and install special coating systems in accordance with the Contract Documents.

DIVISION 9 FINISHES Section Floor Finishes

FIVE STAR PRODUCTS, INC.

TECHNICAL REQUIREMENTS AND SPECIFICATIONS. PROTECTIVE COATING OF STEEL (As Provided by Raven Lining Systems) FOREWORD

1.2 SUMMERY A. Section Includes: 1. High-Performance Polyurethane Resinous flooring systems. 2. Decorative Polyurethane Resinous flooring systems.

Lessons Learned from a 60 CIPP Storm Sewer Liner Installation. Robert Stolt, PE Christopher Beranek, PE

ERSYSTEMS OneStep Plus

Effective Date: Revision #: 1. Section N: Concrete. Concrete/ Type S Mortar. Cement/ Calcium Aluminate

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric Sealant

SECTION DOWNSTREAM DEFENDER

Transcription:

1.01 DESCRIPTION SPECTRASHIELD Total System for Large Wastewater Structures PART I - GENERAL The work described within details a complete program for wet wells, treatment plants or other large wastewater structures. This section details the methods, procedures, materials and equipment as required to produce A Total System for Large Wastewater Structures. The completed system will provide a corrosion resistant liner to rehabilitate deteriorated structures and prevent further deterioration from hydrogen sulfide and other corrosive gases/acids within the wastewater stream. 1.02 SUBMITTALS All materials and procedures required to establish compliance with the specifications shall be submitted to the owner/engineer for review/approval. Submittals shall include at least the following: 1. Descriptive literature, bulletins and or catalogs of materials. 2. Work procedures including flow diversion plan, method of repair, etc. 3. Material and method for repair of leaks or cracks in concrete structures. 4. Final installation report on completed structures. 1.03 10-YEAR LIMITED WARRANTY SpectraTech, LLC (ST) warrants its SPECTRASHIELD wastewater structure liner against failure for a period of 10 years. Failure will be deemed to have occurred if the protective liner fails to (a) prevent the internal damage or corrosion of the structure (b) protect the substrate and environment from contamination from effluent. If any such failure within 10 years of completion of work by ST on a structure, ST will repair the damage and restore the lining at no cost to the Owner within 60 days after written notification of the failure. Failure does not include damage resulting from mechanical or chemical abuse or act of God. Mechanical or chemical abuse means exposing the lined surfaces of the structure to any mechanical force or chemical substance not customarily present or used in connection with the structures of the type involved. ST makes no warranties express or implied other than those specifically stated in this section 1.03. Any liability for consequential and incidental damages is expressly disclaimed. ST s liability is limited to and shall not exceed the purchase price paid. 1.04 QUALITY ASSURANCE A. The manufacturer and/or installer of the total liner system of concrete structures shall be a company that specializes in the design, manufacture or installation of corrosion protection systems for concrete structures including wetwells, junction chambers, etc. Installer shall be completely trained in leak repair, surface preparation and corrosion materials application on concrete structures. Corrosion materials/products shall be suitable for installation in a severe hydrogen sulfide environment without any deterioration to the liner and shall completely prevent the breakdown of concrete surfaces. B. To ensure total unit responsibility, all materials and installation thereof shall be furnished and coordinated with/by one supplier/installer who turnkeys the work and assumes full responsibility for the entire operation.

PART II - PRODUCTS 2.01 MATERIALS AND EQUIPMENT A. The materials to be utilized in the lining of concrete structures shall be designed and manufactured to withstand the severe effects of hydrogen sulfide in a wastewater environment. Manufacturer of corrosion protection products shall have long proven experience in the production of the coating products utilized and shall have satisfactory installation record. B. Abrasive blasting equipment or high pressure (min. 20,000psi) hydro blasting shall be utilized to completely remove deteriorated concrete and hard contaminants from the existing concrete surfaces. Containment unit to capture spent abrasive material shall be provided unless otherwise approved by the owner/engineer. C. Equipment for installation of lining materials shall be high quality grade and be as recommended by the manufacturer. D. The lining system to be utilized for concrete structures shall be a multi-component stress skin panel liner system as described below: 1. Liner. Installation Moisture displacement barrier Moisture barrier Surfacer Final corrosion barrier Liner Primer Modified Polymer Polyurethane/Polymeric blend foam Modified Polymer 2. Primer shall be 100% solids 3. Modified polymer shall be sprayable, solvent free, two-component polymeric, moisture/ chemical barrier specifically developed for the corrosive wastewater environment. TYPICAL CHEMICAL ANALYSIS A Component Viscosity, 77 F, cps., ASTM D-1638 300-400 Clear to amber Reacts with water B Component Viscosity, 160 F, cps., ASTM D-1638 400-600 Flamingo Pink Non-Volatile 100% REACTION PROFILE (100 grams, 175 F sample) Gel Time, seconds 1-2 Tack Free Time, seconds 15 Cure Time, seconds 30 PROCESSING A System / B System, volume ratio 1.00 / 1.00

TYPICAL PHYSICAL PROPERTIES Tensile Strength, PSI >1500 Elongation, % >125 Tear Strength, PSI 350 Shore D Hardness 55-65 100% Modulus, PSI >1500 4. Polyurethane Rigid Structure Foam - low viscosity two-component containing flame retardants TYPICAL CHEMICAL ANALYSIS A Component Viscosity, 77 F, cps., ASTM D-1638 200 Dark Brown Reacts with water and evolves CO2 gas B Component Viscosity, 77 F, cps., ASTM D-1638 600-1000 Tan Absorbs water rapidly thus changing ratio Reaction Profile (100 grams, 77 F sample) Cream Time, seconds 1-4 Tack Free time, seconds 5-8 Rise Time, seconds 6-10 Processing A System / B System, volume ratio 1.00 / 1.00 Typical Physical Properties Density, nominal, core, lbs/ft3 ASTM 4-10 D-1622 @ 74 F Compression Strength, ASTM D-1621 90-150 @ 74 F parallel rise; PSI Closed Cell Content, % - ASTM 1940 @ 74 F Over 90 Shear Strength, PSI - ASTM C-273 @ 74 F 225-250 5. Total thickness of multi-component stress panel liner shall be a minimum of 500 mils. Product shall be SPECTRASHIELD by CCI Spectrum, Inc. PART III EXECUTION 3.01 INSPECTION Prior to conducting any work, perform inspection of structure to determine need for protection against hazardous gases or oxygen depleted atmosphere and the need for flow control or flow diversion.

Submit plan for flow control or bypass to owner/engineer for approval prior to conducting the work. 3.02 SURFACE PREPARATION A. Conduct surface preparation program to include monitoring of atmosphere for hydrogen sulfide, methane, low oxygen or other gases, approved flow control equipment, and abrasive blasting equipment. B. Hydro blasting (min 20,000 p.s.i) or abrasive blasting equipment shall remove all deteriorated concrete, hard contaminants, localized micro- organisms and gas contaminants, from the concrete walls, floors or other structures. Final product shall be cleaned, exposed and virgin concrete aggregate ready for rehabilitation material. C. After completion of surface preparation, blasting phase, perform the seven point check list, which is the inspection for: 1. Leaks 5. Ring and Cover condition 2. Cracks 6. Invert Condition 3. Holes 7. Inlet and Outlet Pipe Condition 4. Exposed Rebar D. After the defects in the structure are identified, repair all leaks with a chemical or hydraulic sealant designed for use in field sealing of ground water. Severe cracks shall be repaired with a urethane based chemical sealant. Product to be utilized shall be as approved by owner/engineer prior to installation. Repairs to exposed rebar, defective pipe penetrations or inverts, etc. shall be repaired utilizing non-shrink grout or approved alternative method. E. Prior to application of final liner application, if required, re-blast the entire structure and remove all abrasive materials. 3.03 MATERIAL INSTALLATION A. The limits of the corrosion protection system shall be all exposed concrete/brick surfaces including walls, tap sections, risers, etc; unless otherwise directed by the owner/engineer. B. Application of multi-component system shall be in strict accordance with manufacturer s recommendation. Final installation shall be a minimum of 500 mils. A permanent identification number and date of work performed shall be affixed to the structure in a readily visible location. C. Provide final written report to owner/engineer detailing the location, date of report, and description of repair. 3.04 INSPECTION Final concrete/brick structure corrosion protection system shall be completely free of pinholes or voids. Entire exposed concrete/brick surface shall be protected with corrosion protection system. Liner thickness shall be the minimum value as described here. 3.05 REPAIR OF DEFECTS All defects identified during inspection such as pinholes, low film millage, etc. shall be repaired with same material. CCI Spectrum, Inc. reserves the right to change or amend specifications without prior written notice. (Revised 03/04)

TYPICAL PUMP STATION