EXTERIOR IMPROVEMENTS, SECTION 504 CONVERSION, AND HVAC UPGRADES

Similar documents
Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Kelly Village Apartments 3118 Green Houston, Texas 77020

SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

ALL DIMENSIONS FROM FINISHED FACE OF PARTITION TO FINISHED FACE OF PARTITION UNLESS OTHERWISE NOTED.

MECHANICAL M-1 LEGEND AND DETAILS M-2 FLOOR PLAN - DUCTWORK M-3 FLOOR PLAN - PIPING

LANSING HOUSING COMMISSION NOTICE OF REQUEST FOR PROPOSALS RFP No. 1-AMP Christopher Christopher Repair

LANSING HOUSING COMMISSION NOTICE OF REQUEST FOR PROPOSALS RFP No

STANDARD CONSTRUCTION PACKAGE Addendum A REV SITE & EXCAVATION Layout of the foundation and septic system as approved by local and state author

APPLICATION FOR FINISHED BASEMENT PERMIT

Permit Posting and Inspection Procedures

Asbestos Abatement: See Asbestos Survey and Specification. Abatement for seven (7) onebedroom units floors 7-13.

BIDDING SHEET CHECKLIST--SUBCONTRACTORS AND SUPPLIERS SUBCONTRACTOR/ PHONE DATES SUPPLIER NAME: CALLED BID. Sample

Cheshire, CT. By: A.M. Napolitano, LLC. Project Manager: Carolyne Sakonchick Ext. 323

Whitley Shower Locker Toilet Facilities

Waikoloa Homesites. Kohala Coast, HI. Outline Specifications. Prepared By: 16 December 15

Schedule C STANDARD Specifications

Pulaski County, Virginia

Typical Finished Basement Details

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Delta Gamma Sorority Renovation Budget Scope 3/7/2018

Chapter 33 - Checklists

Smokey Ridge, Christiansburg, Virginia

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits

TABLE OF CONTENTS Public Safety Building

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com

Inspection Report. Property Address:

Carter's Oshkosh (SIS) # The Center at Pearland Parkway - Pearland, TX Scope Of Work / Bid Qualifications

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

PROCUREMENT AND CONTRACTING DOCUMENTS GROUP

ADDENDUM 2 - JULY 14, 2015

Boyle. contemporary new homes with great curb appeal. boyle call or 3br/2.5bth, 1905sf

PROGRAM COST MODEL. for. PEER Tall Buildings Study Concrete Structural Option Los Angeles, California

PHASE I ACADEMIC BUILDING CORE RENOVATIONS RCNJ Project No C

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Estimate Form for Bathroom Design and Installation

GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS. New Construction & Rehab

Schedule D. RTM Finished Home Specifications

A/E Design Deliverable Checklist

Distances are not shown to scale. Existing porch. Community. Building. Distances are not shown to scale

Home Inspection Report

MARSHALL HOUSING AUTHORITY

PLANNING FOUNDATION FRAMING

Rental Inspection Checklist

Universal Design Standards

March 2018 Progress. Work Completed, Week Ending 3/23/18:

ADDENDUM A CONSTRUCTION SPECIFICATIONS

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Fairfax County, Virginia

NAAHB Workgroup Index General Ledger Account

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

Proposal. Lexington, MA. Price Work Description

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY

C P A. Presented By Jason G. Smith, CCM, LEED AP. Founder and Principal of Construction Analysis and Planning, LLC

SERIES 0 BIDDING REQUIREMENTS AND CONTRACT FORMS

6'-0" G-4 ADJUSTABLE SHELVING 2'-0" 4'-5" MOP SINK STORAGE '-0" 2'-0" 26'-6" G-4 6' X 4' OPENING WITH SHUTTER BASE CABINETS 34" FOR ADA 20'-0"


Watercrest - Sand Hill - Columbia, SC TABLE OF CONTENTS PROCUREMENT AND CONTRACTING REQUIREMENTS

WORK DESCRIPTION HOUSING REHABILITATION PROGRAM HOUSING DEVELOPMENT DIVISION CITY OF COLORADO SPRINGS

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

What this Family Room Specification Package can be used for:

COOL AMENITIES for Modern Living

Project #1139 Budget #82. $ Budgeted $ Billed to Date $ Paid to Date $ Due 210, , , ,158.50

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

Handyman & Maintenance Cost Estimator

Davis Frame Co., Inc. Construction Budget Considerations

Division 00 Procurement and Contracting Requirements

RB Homes, Inc. 152 Witherspoon St. Princeton, NJ P: (609) / F: (609)

Franklin Hall Renovation TABLE OF Document Indiana University Bloomington

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

pershing+ desperes uichomes.com 6005 and 6007 Pershing Avenue pershing+desperes call or

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.

RB Homes, Inc. 152 Witherspoon St. Princeton, NJ P: (609) / F: (609)

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

Friendly Inspection Services

APPENDIX 1 PROJECT REQUIREMENTS

Columbia County Health Care Center Added Amenities

$308,900. Caleb Crescent Collection The Algonquin Model 1113 Sq. Ft. Elevation A. Updated: September 28, Elevation B

Home Inspection Report

NC State University Design and Construction Guidelines Division 00 Planning & Design Space Planning

SECTION OUTLET, PULL, AND JUNCTION BOXES

Sams & Associates York Field Services

186 TH AIR REFUELING WING KEY FIELD, MERIDIAN, MS ADDENDUM #1 PERFORMANCE WORK STATEMENT

Appalachian Log Structures Construction Cost Estimating Guide

Summary. Inspect It Like A Girl. P.O. Box 2283 Madison, MS Customer Happy Home. Address 123 Happy Home Road Jackson MS 39157

678 Ridley Circle Fire Loss Repairs

Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code

The Inspector. Property Inspection Report

Pinnacle Home Inspections, Inc. Serving Central Arkansas

COLONIAL PLANS. 708 North Street US Highway Route 1 Houlton, Maine (207)532,2444

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

Burlington Model at Country Hills Estates

2003 International Residential Building Code

Transcription:

EXTERIOR IMPROVEMENTS, SECTION 504 CONVERSION, AND HVAC SHEET No. G-1 C-1 AB-1 A-1 A-2 A-3 A-4 INDEX OF DRAWINGS COVER SHEET SHEET TITLE DEMOLITION SITE PLAN AND RENOVATION PLAN ABATEMENT PLAN UNIT 91- KEY SITE PLAN, EXTERIOR ELEVATIONS, AND NOTES - IL-41-7/METROPOLIS DETAILS AND PICTURES - IL-41-7/METROPOLIS DEMOLITION AND RENOVATION FLOOR PLANS - UNIT 91- DETAILS AND INTERIOR ELEVATIONS - PROJECTS: IL-41-7/METROPOLIS (HUMMA BUILDING) IL-41-8/BROOKPORT (FAIRMOUNT) MEP-1 MEP-2 MEP-3 MECHANICAL PLAN - TYPICAL 'A' UNIT- AND TYPICAL 'C' UNIT - IL-41-8/METROPOLIS PLUMBING AND MECHANICAL PLANS - UNIT 91 - ELECTRICAL PLANS - UNIT 91- FOR THE: STATE LOCATION MAP PAUL McKNIGHT, EXECUTIVE DIRECTOR UNDER THE: MODERNIZATION PROGRAM IL01P041-501-17 U.S. DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT DATE: ARCHITECTS PROJECT No. ARCHITECT: MASSAC COUNTY EXTERIOR IMPROVEMENTS SECTION 504 CONVERSION, AND HVAC SEAL ASBESTOS PROFESSIONAL LICENSE IDPH ID No. 100-11375 PROJECT DESIGNER ST LIC AT ENS E OF MARK B. DILLON 001-017877 ED A ILL HI RC IN O S E T I CT COVER SHEET PROJECT No. SET No. G-1 1

1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND MAKE ADJUSTMENTS AS NECESSARY TO WORK WITH EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 2. DIMENSIONS GIVEN ARE FOR CONTRACTORS GENERAL INFORMATION ONLY. CONTRACTOR SHALL FIELD VERIFY EXACT DIMENSIONS. 3. CONTRACTOR SHALL FINE GRADE, FERTILIZE, SEED AND STRAW ALL AREAS OF THE SITE DISTURBED BY WORK IN THIS PROJECT. SEE SPEC SECTION 32 92 00. 4. IT IS CONTRACTORS RESPONSIBILITY TO DETECT AND LOCATE ANY AND ALL UNDERGROUND UTILITIES INCLUDING PHA OWNED UTILITIES. CONTRACTOR SHALL NOT DISTURB EXISTING UTILITIES UNLESS NOTED OTHERWISE. NOTIFY ARCHITECT OF ANY CONFLICTS WHICH MAY OCCUR. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING J.U.L.I.E. BEFORE BEGINNING CONSTRUCTION AND ANYTIME UTILITY MARKINGS NEED TO BE RE-ESTABLISHED. (PHONE: 800-892-0123). 5. NEW WALKS SHALL MATCH EXISTING ADJOINING WALKS FOR A SMOOTH TRANSITION. 6. BACKFILL ALONG NEW CONCRETE SIDEWALKS AFTER REMOVAL OF FORMS. 7. SLOPE OF NEW WALKS SHALL NOT EXCEED 5% IN THE DIRECTION OF TRAVEL OR 2% CROSS SLOPE. 8. SEE SECTION 01 45 29 FOR MATERIAL TESTING REQUIREMENTS. 9. SEE MEP SHEETS FOR NEW CONCRETE PADS FOR CONDENSING UNITS. UNIT NUMBER BUILDING TYPE CONCRETE WALK AND BASE TO BE REMOVED NEW CONCRETE NOT IN CONTRACT EXISTING ELEVATION TO REMAIN FINISH ELEVATION EXISTING ELEVATION GRADE TO DRAIN IN DIRECTION SHOWN DIRECTION OF FLOW OF EXISTING EXISTING CONCRETE WALK TO REMAIN. TAKE CARE NOT TO DAMAGE. SAW CUT AND REMOVE 4"± THICK REINFORCED CONCRETE WALK TO EXTENTS SHOWN. EXCAVATE SOIL BELOW DEMOLISHED SLAB MINIMUM 4". EXISTING CONCRETE STOOP TO REMAIN. TAKE CARE NOT TO DAMAGE. EXISTING MAIL BOX BANK TO REMAIN. TAKE CARE NOT TO DAMAGE. EXISTING SITE LIGHTING TO REMAIN. TAKE CARE NOT TO DAMAGE. VERIFY ELECTRICAL CIRCUIT LOCATION PRIOR TO ANY WORK. EXISTING PAVING AND STRIPING TO REMAIN. TAKE CARE NOT TO DAMAGE. EXISTING MECHANICAL EQUIPMENT. COORDINATE WITH MECHANICAL CONTRACTOR FOR NEW EQUIPMENT LOCATION. EXISTING DOWNSPOUT AND SPLASHBLOCK TO REMAIN. GRADE AREA TO DIRECT DRAIN OUTPUT TO NEW CURB DRAIN. SEED AND STRAW ANY DISTURBED AREA. EXISTING ADA PARKING SIGNAGE TO REMAIN. TAKE CARE NOT TO DAMAGE. EXISTING ELECTRICAL TRANSFORMER. TAKE CARE NOT TO DISTURB EXISTING CONCRETE WALK TO REMAIN. TAKE CARE NOT TO DAMAGE. PLACE NEW 4" THICK REINFORCED CONCRETE WALK OVER TYPE 'B' BACKFILL. REFER TO DETAIL 1/C-1. RAISE SUBGRADE AS NECESSARY TO ATTAIN NEW FINISH ELEVATION. DRILL-IN (MIN. 6") AND EPOXY IN PLACE 1 2" DIA. x 12" LONG SMOOTH STEEL DOWELS WITH SLIP CAP AT END AT 12" O.C. WHERE NEW WALKS ABUT EXISTING. REFER TO TYPICAL SIDEWALK DETAIL 1/C-1. NEW WALK DRAIN - SEE DETAIL 2/C-1. RE-GRADE YARD AREA FOR PROPER DRAINAGE AWAY FROM BUILDING. EXISTING STOOP TO REMAIN. TAKE CARE NOT TO DAMAGE. VERIFY EXISTING SWALE FOR PROPER DRAINAGE AWAY FROM WALKS AND BUILDING. RESET EXISTING SPLASHBLOCK AT NEW GRADE. BACKFILL, FINE GRADE, SEED AND STRAW AREAS FOR PROPER DRAINAGE AWAY FROM EXISTING BUILDING DUE TO REMOVAL OF EXISTING CONCRETE WALK. INSTALL NEW 36"x 36"x 4" THICK CONCRETE EQUIPMENT PAD FOR NEW CONDENSING UNIT. COORDINATE LOCATION WITH MECHANICAL CONTRACTOR, ARCHITECT, AND PHA. SEE SHEET MEP-1 FOR LOCATIONS OF UNITS WITH NEW EQUIPMENT. SEE DETAIL 3, THIS SHEET. DEMOLITION SITE PLAN AND RENOVATION PLAN C-1 1

1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND MAKE ADJUSTMENTS AS NECESSARY TO WORK WITH EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 2. REMOVE AND PROPERLY DISPOSE OF 1 LAYER OF FLOOR TILE AND MASTIC IN A NON-FRIABLE MANNER AS INDICATED ON THE FLOOR PLANS. SEE SECTION 02 08 50. 3. THE ABATEMENT SUBCONTRACTOR SHALL REMOVE AND DISPOSE OF THE THRESHOLD TO THE EXTERIOR DOOR. 4. THE ABATEMENT SUBCONTRACTOR SHALL REMOVE THE WATER CLOSET AT IL-41-9 AND TURN OVER TO GENERAL CONTRACTOR FOR DISPOSAL. 5. THE ABATEMENT SUBCONTRACTOR SHALL REMOVE ANY AND ALL FLOOR MOUNTED ITEMS INCLUDING BI-FOLD DOOR TRACK, TRANSITION STRIPS, FLOOR MOUNTED DOOR STOPS, BYPASS DOOR TRACKS, ETC. THAT ARE AFFECTED BY THE REMOVAL OF THE FLOOR TILE. COORDINATE WITH GENERAL CONTRACTOR. 6. COORDINATE WITH GENERAL CONTRACTOR FOR REMOVAL OF SWING DOORS AND FRAMES. ABATEMENT CONTRACTOR TO ABATE FLOOR TILE AND MASTIC AS SHOWN. COORDINATE WITH GENERAL CONTRACTOR FOR ITEM TO BE SALVAGED TO THE PHA. (REFRIGERATOR, STOVE, ETC.) WATER CLOSET TO BE REMOVED BY ABATEMENT SUBCONTRACTOR. SEE GENERAL NOTE 4 THIS SHEET. REMOVE AND DISPOSE OF BI-PASS DOOR AND FLOOR TRACK. COORDINATE WITH GENERAL CONTRACTOR. REMOVE FLOOR TILE BELOW EXISTING FURNACE, COORDINATE WITH MECHANICAL SUBCONTRACTOR FOR DISCONNECTION AND REMOVAL OF EXISTING UNIT. REMOVE FLOOR TILE AND MASTIC AT MECHANICAL ROOM. COORDINATE ABATEMENT WITH PLUMBING SUBCONTRACTOR FOR ACCESS BELOW WATER HEATER. NON-ACBM FLOOR TILE TO BE REMOVED BY GENERAL CONTRACTOR. ACM FLOOR TILE AND MASTIC TO BE ABATED IN A NON-FRIABLE MANNER. SEE GENERAL NOTE No. 2. THRESHOLD LOCATION. SEE GENERAL NOTE No. 3. TRANSITION STRIP ABATEMENT PLAN UNIT91 AB-1 1

1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND MAKE MINOR ADJUSTMENTS AS NECESSARY TO WORK WITH EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 2. PROVIDE BARRIERS TO PROTECT PEDESTRIANS, TENANTS, VEHICLES, VEGETATION, ETC. FROM DEBRIS OR OTHER HAZARDOUS CONDITIONS. DUE TO WORK ACTIVITIES. 3. REPAIR ALL LAWN AREAS DISTURBED BY WORK PERFORMED UNDER THIS CONTRACT. 4. CONTRACTOR SHALL PROTECT ADJACENT WALL SURFACES, WINDOWS, DOORS, ETC. FROM DAMAGE. 5. REMOVE EXISTING CMU FROM AREA SHOWN ON THE ELEVATIONS AND INSTALL NEW CMU. RE-POINT ALL CMU JOINTS AT ALL PANELS AND PREP FOR ELASTOMERIC COATING, INSTALL ELASTOMERIC COATING AND SEALANT AS DETAILED. 6. ACCESS TO FIRE SYSTEM STAND PIPE CONNECTION AT EXTERIOR SHALL REMAIN CLEAR DURING ALL CONSTRUCTION ACTIVITIES. 7. CONTRACTOR SHALL COMPLETELY REMOVE EXISTING SEALANT FROM ALL BUILDING JOINTS AND INSTALL NEW BACKER ROD AND SEALANT. 8. CONTRACTOR SHALL CLEAN ALL NEW MASONRY AND AREAS WHERE WORK IS PERFORMED. 9. EXISTING SEALANT AT DOORS, WINDOWS, AC SLEEVES, ETC. SHALL BE REMOVED AND NEW SEALANT INSTALLED. 10. DRILL MORTAR JOINTS AT WINDOW AND DOOR LINTELS TO REMAIN AND INSTALL COTTON ROPE WEEPS (MINIMUM OF 3 PER OPENING) REMOVE EXISTING DAMAGED MASONRY. INSTALL NEW CMU, FLASHING, WEEPS, AND ACCESSORIES. SEE DETAILS. INSTALL BLOCK FILLER AT INTERIOR OF NEW CMU, PRIME AND (2) COATS PAINT (CORNER TO CORNER, FLOOR TO CEILING) AT INTERIOR. APPLY ELASTOMERIC COATING ON CMU AT EXTERIOR EXISTING CMU TO REMAIN. RE-POINT ALL CMU JOINTS AND PREP FOR ELASTOMERIC COATING INSTALLATION. INSTALL ELASTOMERIC COATING AND SEALANT AS SPECIFIED. RE-POINT EXISTING BRICK SILLS. PREP AND INSTALL ELASTOMERIC COATING TO SILL. TAKE CARE NOT TO DAMAGE WINDOW. EXISTING WINDOWS, DOORS, AND AC SLEEVES TO REMAIN (TYP.) - TAKE CARE NOT TO DAMAGE. REMOVE AND REPLACE ALL SEALANT AND BACKER ROD. EXISTING LINTEL TO REMAIN. CLEAN AND PAINT STEEL ANGLE - SEE SPECIFICATION SECTION 09 90 00. SEE DETAILS FOR FLASHING REQUIREMENTS. COMPLETELY REMOVE EXISTING SILICONE SEALANT AND BACKER ROD IN ITS ENTIRETY. SAW CUT TO WIDEN JOINT TO 3 4" WIDE. PROVIDE NEW SEALANT AND BACKER ROD. PREP EXISTING CEILING / SOFFIT AND APPLY WATERPROOFING / ELASTOMERIC COATING. EXISTING PARAPET CAP, REMOVE AND REPLACE ALL SEALANT AT JOINTS - TAKE CARE NOT TO DAMAGE. EXISTING ELECTRICAL WEATHER-HEADS AND BOXES. TAKE CARE NOT TO DAMAGE. EXISTING EXTERIOR AREA LIGHTING ON BUILDING SHALL REMAIN. TAKE CARE NOT TO DAMAGE. LOOSEN EXISTING SURFACE MOUNTED CONDUIT AS NECESSARY TO PERFORM WORK UNDER THIS CONTRACT. RE-SECURE AFTER PERFORMING WORK. TAKE CARE NOT TO DISTURB EXISTING SECURITY CAMERAS. COORDINATE CAMERA VIEW WITH PHA AFTER WORK IS COMPLETE TO VERIFY VIEW HAS NOT CHANGED. PREP DOOR AND FRAME TO ACCE (2) COATS PAINT. PRIME ALL BARE METAL PRIOR TO APPLYING PAINT. EXISTING LOUVER AND VENT / EXHAUST PIPING TO REMAIN. TAKE CARE NOT TO DAMAGE. REMOVE AND REPLACE EXISTING SEALANT AT PERIMETER OF OPENING. REMOVE EXISTING AND SEAL AROUND CABLE / CONDUIT PENETRATIONS AT MASONRY. TYPICAL EXISTING ROOF/WALL FLASHING - TAKE CARE NOT TO DAMAGE. KEY SITE PLAN, EXTERIOR ELEVATIONS AND NOTES IL-41-7/METROPOLIS A-1 5

DETAILS AND PICTURES IL-41-7/METROPOLIS A-2 5 ING IDD RB FO LY ON

1. FIELD VERIFY EXISTING CONDITIONS AND MAKE MINOR ADJUSTMENTS AS NECESSARY. NOTIFY ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 2. COORDINATE DEMOLITION WORK WITH ALL SUBCONTRACTORS. COORDINATE MECHANICAL, ELECTRICAL AND PLUMBING DEMOLITION WITH M SHEETS. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, HAULING, AND LEGAL DISPOSAL OF ALL PRODUCTS, EQUIPMENT, AND MATERIAL MARKED FOR DEMOLITION. 4. POST "UNDER CONSTRUCTION - AUTHORIZED ENTRY ONLY" SIGNS AT ALL DOORS/ACCESS TO WORK AREAS. 1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND MAKE MINOR ADJUSTMENTS AS NECESSARY TO WORK WITH EXISTING CONDITIONS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 2. EXTERIOR DIMENSIONS ARE FROM OUTSIDE FACE OF BRICK. INTERIOR DIMENSIONS ARE SHOWN FROM FACE OF STUD AT NEW PARTITIONS AND FROM FACE OF EXISTING FINISH AT EXISTING PARTITIONS TO REMAIN. DIMENSIONS ARE GIVEN FOR GENERAL INFORMATION AND SHALL BE FIELD VERIFIED. 3. GENERAL CONTRACTOR SHALL COORDINATE WORK WITH ABATEMENT, ELECTRICAL, MECHANICAL, AND PLUMBING SUBCONTRACTORS. SEE MEP DRAWINGS FOR AREAS THAT REQUIRED WALL, CEILING, OR FLOOR PATCHING AND REPAIRS. REMOVE GYPSUM BOARD WALL FINISH AND BASEBOARD, CORNER TO CORNER, FLOOR TO CEILING - COORDINATE WITH RENOVATION PLAN. 4. CONTRACTOR SHALL PROTECT EXISTING SURFACES / EQUIPMENT FROM DUST, DIRT, ETC. DURING ALL CONSTRUCTION ACTIVITIES. AFTER ALL WORK IS COMPLETED, CONTRACTOR SHALL CLEAN ALL AREAS AFFECTED SO THAT THEY ARE FREE OF ANY AND ALL CONSTRUCTION DEBRIS AND DIRT. 5. INSTALL NEW 12" SQUARE FLOORING, SHEET FLOORING, AND BASE THROUGHOUT UNIT AS INDICATED ON FINISH SCHEDULE. REMOVE EXISTING SLIDING DOOR AND OVERHEAD HARDWARE. COORDINATE WITH ABATEMENT SUBCONTRACTOR FOR FLOOR TRACK REMOVAL REMOVE EXISTING 30" TALL WALL CABINET FOR INSTALLATION OF NEW WALL CABINET AT EXISTING LOCATION. TURN OVER TO PHA. REMOVE EXISTING GYPSUM BOARD AT CEILING. REMOVE EXISTING BATT INSULATION AT RAFTER SPACE. 6. INSTALL SOLID WOOD BLOCKING IN WALLS FOR ANCHORING WALL MOUNTED DOOR STOPS, BATHROOM ACCESSORIES AND SHELVING. REMOVE EXISTING GRAB BAR. REMOVE EXISTING PARTITION TO LIMITS SHOWN. REMOVE EXISTING APPLIANCES AND TURN OVER TO PHA. SAW CUT AND REMOVE EXISTING CONCRETE SLAB FOR NEW RECESSED SHOWER BASE. COORDINATE WITH PLUMBING SUBCONTRACTOR. REMOVE AND DISPOSE OF EXISTING SHELVING AND CLOTHES ROD. REMOVE EXISTING DOOR, TRIM, AND FRAME. REMOVE EXISTING SCREEN DOOR AND SALVAGE FOR RE-INSTALLATION. SEE SITE PLAN SHEET C-1 FOR EXTERIOR STOOP AND WALK DEMOLITION. REMOVE EXISTING DOOR, FRAME, AND HARDWARE AND TURN OVER TO PHA. COORDINATE WITH ELECTRICAL DRAWINGS FOR REMOVAL OF SWITCHES, DEVICES, PLATES AND MISC. ELECTRICAL DEMOLITION. REMOVE AND DISPOSE OF EXISTING PORCELAIN TILE SHOWER SURROUND, ACCESSORIES, AND TUB. COORDINATE WITH PLUMBING CONTRACTOR. REPLACE GYP. BOARD ON WALLS AND PARTITIONS WHERE REMOVED. FINISH SMOOTH TO ADJACENT EXISTING TO REMAIN. MATCH ADJACENT GYP. BOARD THICKNESS AT EXISTING PARTITIONS. PLUMBING SUBCONTRACTOR SHALL INSTALL NEW LAVATORY AND WATER CLOSET AFTER INSTALLATION OF NEW FLOORING. PATCH/REPAIR FLOOR AND CEILING DUE TO REMOVAL OF EXISTING PARTITION, INSULATE ATTIC WHERE INSULATION WAS DISTURBED. BLEND PATCHES AND REPAIRS INTO EXISTING. PREPARE EXISTING CONCRETE FLOOR AS NECESSARY FOR NEW FLOORING. INSTALL NEW 12" SQUARE FLOORING AND 4" VINYL BASE. INSTALL RANGE AND ANTI-TIP DEVICE PROVIDED BY THE PHA. INSTALL REFRIGERATOR PROVIDED BY THE PHA. NEW PLYWOOD SHELVING, PRIME AND (2) COATS PAINT - SEE DETAIL, SHEET A-4. INSTALL NEW 5 8" TYPE 'X' GYP. BOARD AT CEILING. ATTACH TO EXISTING FRAMING. PATCH CONCRETE SLAB WITH 4" OF REINFORCED CONCRETE OVER VAPOR RETARDER AND 4" ( MIN.) OF COMPACTED TYPE "B" PACKFILL. SEE DETAIL 1 / SHEET A-4. COORDINATE WORK WITH PLUMBING CONTRACTOR. NEW LOAD CENTER LOCATION - COORDINATE WITH ELECTRICAL SUBCONTRACTOR. AREA OF EXISTING NON-ACBM FLOOR TILE TO BE REMOVED, AND DISPOSED OF - COORDINATE WITH NEW PARTITION LAYOUT AND PLUMBING SUBCONTRACTOR. AREA OF EXISTING CONCRETE FLOOR SLAB TO BE SAW CUT, REMOVED, AND DISPOSED OF - COORDINATE WITH PLUMBING SUBCONTRACTOR. REMOVE EXISTING MIRROR, MEDICINE CABINET, AND ACCESSORIES. COORDINATE WITH PLUMBING SUBCONTRACTOR FOR REMOVAL OF EXISTING LAVATORY AND WATER CLOSET. COORDINATE WITH MECHANICAL SUBCONTRACTOR FOR REMOVAL OF FURNACE AND ACCESSORIES. EXISTING SHELVING TO REMAIN. CLEAN AND PAINT. INSTALL NEW WOOD DOOR TRIM - MATCH EXISTING CONSTRUCTION. GENERAL CONTRACTOR TO PROVIDE NEW SHOWER BASIN TO BE INSTALLED BY PLUMBING SUBCONTRACTOR. PROVIDE AND INSTALL NEW SHOWER SURROUND AND TRIM. INSTALL ACCESSORIES AT SHOWER (PROVIDE SOLID WOOD BLOCKING AT ALL ACCESSORIES). PARTITION TO BE REMOVED REMOVE EXISTING DOOR LOCK AND TURN OVER TO PHA. REMOVE EXISTING GYP. BOARD. COORDINATE WITH ELECTRICAL SUBCONTRACTOR FOR EXTENTS. LIVING ROOM LAUNDRY KITCHEN AND DINING FURNACE ELEVATION NUMBER SHEET ELEVATION FOUND ON DOOR NUMBER MATERIAL FINISH EXIST. GB 8'-0" 1, 2 GB NEW PARTITION - TYPE NOTED. SEE SCHEDULE THIS SHEET 1, 2 1, 2, 4 1, 2, 4 MECH. AND STORAGE GB 8'-0" 1, 2, 4 T.S. EXIST. GB EXIST. GB TRANSITION STRIP LOCATION 8'-0" 8'-0" 8'-0" SEE SITE PLAN, SHEET C-1 FOR EXTERIOR IMPROVEMENTS EXISTING ELECTRIC PANEL, COORDINATE WORK WITH ELECTRICAL CONTRACTOR. SEE MEP-2. COORDINATE MECHANICAL EQUIPMENT INSTALLATION WITH MECHANICAL SUBCONTRACTOR. INSTALL NEW 30"W X 36" T WALL CABINET AT EXISTING LOCATION. INSTALL SO THAT TOP OF CABINET IS LEVEL WITH EXISTING WALL CABINETS. COORDINATE WITH ELECTRICAL SUBCONTRACTOR TO RELOCATE EXISTING RECEACLE. REPAIR EXISTING WATER DAMAGE AT GYPSUM BOARD CEILING. REPAIR GYPSUM BOARD AND HPDL AS NECESSARY FOR CABINET AND RECEACLE RELOCATION. COORDINATE WITH ELECTRICAL SUBCONTRACTOR. RE-INSTALL EXISTING SCREEN/STORM DOOR ON NEW FRAME. FURR CEILING AREA WITH WOOD FRAMING AND GYP. BOARD TO CREATE SPACE FOR CONDENSATE LINE. COORDINATE DEH REQUIRED WITH HVAC CONTRACTOR. BEDROOM EXIST. GB 8'-0" 1, 2, 4 1. ALL NEW AND EXISTING METAL DOORS AND FRAMES SHALL BE PRIMED AND PAINTED (INTERIOR AND EXTERIOR) AS PER SPECIFICATIONS. INTERIOR WOOD DOORS SHALL BE PRE-FINISHED. 2. PROVIDE 3 ANCHORS PER JAMB, MINIMUM, FOR ALL SWING DOORS. 3. DIMENSIONS SHOWN FOR WOOD DOORS ARE FINISHED SIZES. 4. CONTRACTOR SHALL FIELD VERIFY EXISTING WALL THICKNESS DOOR OPENING DIMENSIONS, AND DOOR HANDING AT EACH UNIT PRIOR TO ORDERING DOORS. NOTIFY ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 5. SEE SPEC. SECTION 08 70 00 FOR DOOR HARDWARE. 6. ALL WOOD FRAMES TO BE PRE-DRILLED BEFORE INSTALLATION OF ANY HARDWARE. 100 3'-0" x 6'-8" x 1 3/4" THK. 1 HM PAINT WOOD 4 7 8" PAINT 7/A-4 1 VERIFY FRAME WIDTH IN FIELD 101 EXISTING 2 EXIST. PAINT EXISTING - PAINT - 2 102 3'-0" x 6'-8" x 1 3/8" THK. 2 WOOD PRE-FINISHED WOOD 4 9 16" PAINT 3/A-4 3 103 5'-0" x 6'-8" x 3/4" THK. 3 BI-FOLD PRE-FINISHED - - - 4/A-4 6 104 2'-6" x 6'-8" x 1 3/8" THK. 2 WOOD PRE-FINISHED WOOD 4 9 16" PAINT 3/A-4 4 105 3'-0" x 6'-8" x 1 3/8" THK. 2 WOOD PRE-FINISHED WOOD 4 9 16" PAINT 3/A-4 5 106 2'-6" x 6'-8" x 3/4" THK 4 BI-FOLD PRE-FINISHED - - - 4/A-4 6 107 2'-0" x 6'-8" x 3/4" THK 4 BI-FOLD PRE-FINISHED - - - 4/A-4 6 CLOSET (CL.) BATH HALL SH FL SH FL 1. PATCH/REPAIR EXISTING DAMAGED GYP. BOARD WALL SURFACES. SKIM COAT/FLOAT WALL AS NECESSARY AT DISTURBED PARTITIONS. 2. PAINT NEW GYP. BOARD SURFACES WITH ONE PRIME COAT AND TWO FINISH COATS. SAND AND PREP ALL SURFACES PRIOR TO PAINTING IN ACCORDANCE WITH SECTION 09 90 00 AND PAINT MANUFACTURER'S RECOMMENDATIONS. REPAIR ALL DIMPLES, SCRATCHES, NAIL POPS, NAIL HOLES, ETC. IN EXISTING SURFACES. 3. PROVIDE TRANSITION STRIPS AS NEEDED. 4. PATCH/REPAIR EXISTING GYP. BOARD CEILING. EXIST. GB 8'-0" 1, 2, 4 FRP/ GB 8'-0" 1, 2, 3, 4 STORAGE CONC - - GB - 8'-0" - GB EXIST. GB SH FL CONC. 8'-0" EXISTING MATERIAL TO REMAIN GYPSUM BOARD PRIME AND (2) COATS PAINT SHEET FLOORING VINYL BASE VINYL COMPOSITION TILE CONCRETE ( NO WORK) 1, 2, 3, 4 DEMOLITION AND RENOVATION FLOOR PLANS UNIT91 A-3 5

TOILET TISSUE DISPENSER GRAB BAR - LENGTH NOTED MEDICINE CABINET ROBE HOOK SHOWER CURTAIN ROD TOWEL BAR (LENGTH NOTED) 1. SEE MECHANICAL, ELECTRICAL AND PLUMBING SHEETS FOR RELATED WORK. COORDINATE WORK FOR LOCATION OF ELECTRICAL OUTLETS, LIGHT SWITCHES, ETC. 2. INSTALL SOLID WOOD BLOCKING IN WALLS FOR MOUNTING GRAB BARS AND ACCESSORIES. 3. ALL SEALANT IN BATHROOMS SHALL BE MILDEW-RESISTANT. 4. ADJUST LOCATION OF TOILET ACCESSORIES AS NECESSARY TO AVOID CONFLICT WITH PLUMBING AND ELECTRICAL FIXTURES. COORDINATE WITH ARCHITECT IF SUCH CONFLICTS OCCUR. NEW 1x3 WOOD CHAIR RAIL - PRIME AND PAINT, SEE DETAIL 7/A-4. NEW COVE BASE - SEE DETAIL 5/A-4. PRE-FINISHED FIBERGLASS REINFORCED WALL PANEL (FRP). SEE SPEC. SECTION 09 98 50. PROVIDE FINISHED EDGE AT BASE AND CORNER TRIM ALONG WITH SEALANT. LIGHT SWITCH, RECEACLE, OR ALARM PULL STATION - COORDINATE WITH ELECTRICAL SHEETS. NEW WALL MOUNTED LIGHT FIXTURE - COORDINATE WITH ELECTRICAL SHEETS. NEW SURFACE MOUNTED A.D.A. COMPLIANT MEDICINE CABINET WITH MIRROR. NEW CAST-RESIN ROLL-IN SHOWER BASIN AND SHOWER SURROUND WITH SOAP DISH AS SPECIFIED. LOCATE SOAP DISHES SO NOT TO INTERFERE WITH GRAB BARS - (MAX. 48" TO SHELF). CONTINUOUS GRAB BAR. DETAILS AND INTERIOR ELEVATIONS A-4 5

1. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND MAKE ADJUSTMENTS AS NECESSARY TO WORK WITH EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 2. MECHANICAL AND ELECTRICAL SUB-CONTRACTOR SHALL COORDINATE ALL WORK WITH GENERAL CONTRACTOR. 3. THE LAYOUTS SHOWN ON THESES DRAWINGS ARE NECESSARILY DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION WILL PERMIT. CHANGES FROM THESE DRAWINGS REQUIRED TO MAKE WORK CONFORM TO EXISTING BUILDING CONDITIONS SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST TO THE PHA, BUT ONLY WITH PRIOR APPROVAL OF THE ARCHITECT. ALL NEW EQUIPMENT SHALL CONNECT TO EXISTING SERVICES UNLESS NOTED OTHERWISE. PROVIDE FOR ANY NECESSARY MODIFICATIONS OR TRANSITIONS OF EXISTING SERVICES. ALL ELECTRICAL DEVICES MAY NOT EXIST IN LOCATIONS INDICATED - CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS. 4. CONTRACTORS SHALL BE RESPONSIBLE FOR REMOVAL, HAULING, AND LEGAL DISPOSAL OF ALL PRODUCTS, EQUIPMENT, AND MATERIAL. 5. ALL ELECTRICAL WORK TO BE PERFORMED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (CURRENT EDITION) AND ALL LOCAL ELECTRICAL CODES. 6. ALL CIRCUIT CONDUCTORS SHALL BE #12 GA. MINIMUM UNLESS INDICATED OTHERWISE. ALL CIRCUITS SHALL BE CONCEALED IN CONDUIT. 7. BY UNIT PRICE 'B': REPLACE EXISTING AIR HANDLER. RECONNECT EXISTING SUPPLY AND RETURN DUCTS, THERMOSTAT WIRING, GAS PIPING, ELECTRICAL, AND FLUE PIPING. GENERAL CONTRACTOR TO REPLACE CEILING IN FURNACE CLOSET, SEAL ALL PENETRATIONS. NEW COOLING COIL ON TOP OF EXISTING GAS FIRED FURNACE (REMOVE EXISTING AT 41-9). COOLING COIL SHALL BE CC-1. MODIFY DUCT WORK AS NEEDED TO EXTEND TRUNK TO NEW COIL. SEE DETAIL AND SCHEDULE BELOW. REPLACE AIR HANDLER (AH-1) BY UNIT PRICE 'B'. REMOVE AND DISPOSE OF EXISTING FIBERGLASS CONDENSING UNIT PAD. PLACE NEW OUTDOOR CONDENSING UNIT ON NEW 36"x 36"x 4" THICK CONCRETE PAD - SEE DETAIL 3, SHEET C-1. CONDENSING UNIT SHALL BE CU-1. SEE SCHEDULE BELOW. NEW REFRIGERATION PIPING. PIPING TO RUN FROM CONDENSING UNIT, UP OUTSIDE WALL, THRU SOFFIT, INTO ATTIC, THEN OVER TO ABOVE EXISTING FURNACE, THEN DOWN THRU CEILING TO NEW COOLING COIL. PROVIDE REFRIGERANT LINE SET COVER AT EXTERIOR WITH 90 ELBOW AT ENDS. CONNECT NEW EQUIPMENT TO EXISTING CONDENSATE LINE. PROVIDE NEW TRAP AT UNIT. VERIFY THAT THE EXISTING PIPING IS CLEAR OF OBSTRUCTION BEFORE CONNECTING TO NEW EQUIPMENT. TEMPORARILY REMOVE EXISTING SHEET METAL COVER PANEL AND RE-INSTALL UPON COMPLETION OF MODIFICATIONS. REPLACE THERMOSTAT WITH NEW AS SPECIFIED. EXISTING FLUSH MOUNTED PANELBOARD WITH 2P20 BREAKER FOR CONDENSING UNIT AND 1P20 AMP BREAKER FOR FURNACE TO REMAIN. EXISTING 2P30 AMP FUSIBLE DISCONNECT SWITCH TO REMAIN. FLEX TO UNIT WITH (2) #12'S WITH GROUND IN 3 4" PVC COATED FLEXIBLE CONDUIT ON THE LOAD SIDE. EXISTING (2) #12'S WITH GROUND TO EXISTING PANEL ON THE LINE SIDE TO REMAIN. UNIT NUMBER BUILDING TYPE UNIT TO BE INCLUDED IN BASE BID UNIT TO BE INCLUDED BY UNIT PRICE 'A' MECHANICAL PLAN TYPICAL 'A' UNIT TYPICAL 'C' UNIT IL-41-8/METROPOLIS MEP-1 3

1. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND MAKE ADJUSTMENTS AS NECESSARY TO WORK WITH EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 2. CONTRACTORS SHALL PROTECT EXISTING SURFACES/EQUIPMENT FROM DUST, DIRT, ETC. DURING ALL CONSTRUCTION ACTIVITIES. AFTER ALL WORK IS COMPLETED, CONTRACTOR SHALL CLEAN ALL UNITS SO THAT THEY ARE FREE OF ANY CONSTRUCTION DIRT AND DEBRIS. 3. MECHANICAL CONTRACTOR SHALL COORDINATE CUTTING/PATCHING/REPAIRING/PAINTING ALL SURFACES AS NECESSARY FOR THE INSTALLATION OF ALL EQUIPMENT WITH ALL OTHER CONTRACTORS. 4. THE LAYOUTS SHOWN ON THESES DRAWINGS ARE NECESSARILY DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION WILL PERMIT. CHANGES FROM THESE DRAWINGS REQUIRED TO MAKE WORK CONFORM TO EXISTING BUILDING CONDITIONS SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST TO THE PHA, BUT ONLY WITH PRIOR APPROVAL OF THE ARCHITECT. 5. CONTRACTORS SHALL BE RESPONSIBLE FOR REMOVAL, HAULING, AND LEGAL DISPOSAL OF ALL PRODUCTS, EQUIPMENT, AND MATERIAL. 6. ALL NEW MECHANICAL WORK SHALL BE IN FULL COMPLIANCE OF THE INTERNATIONAL MECHANICAL CODE (CURRENT EDITION) AND ALL LOCAL CODES. ANY EXISTING MECHANICAL SYSTEM THAT NEEDS TO BE ALTERED TO ACCOMMODATE THE INSTALLATION OF ANY NEW WORK SHALL BE DONE IN FULL COMPLIANCE WITH ALL APPLICABLE CODES. 7. ALL AIR DUCT JOINTS AND SEAMS SHALL BE SEALED IN A MANNER CONFORMING TO THE REQUIREMENTS OF THE INTERNATIONAL MECHANICAL CODE OR INTERNATIONAL RESIDENTIAL CODE. 8. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE STATE OF ILLINOIS PLUMBING CODE (CURRENT EDITION) AND ALL LOCAL PLUMBING CODES. 9. COORDINATE WITH GENERAL CONTRACTOR FOR REMOVAL OF CONCRETE SLAB FOR PLUMBING MODIFICATIONS. PLUMBING CONTRACTOR SHALL CONFIRM ALL TRENCHING NECESSARY TO REMOVE EXISTING OR INSTALL NEW PLUMBING AND BACKFILL TO MINUS 8" BELOW TOP OF SLAB. 10. INSULATE ALL NEW HOT AND COLD WATER PIPING AN DALL EXISTING PIPING THAT BECOMES EXPOSED DURING CONSTRUCTION. 11. BY UNIT PRICE 'B': REPLACE EXISTING AIR HANDLER. RECONNECT EXISTING SUPPLY AND RETURN DUCTS, THERMOSTAT WIRING, GAS PIPING, ELECTRICAL, AND FLUE PIPING. GENERAL CONTRACTOR TO REPLACE CEILING IN FURNACE CLOSET, SEAL ALL PENETRATIONS. REMOVE EXISTING TOILET, FITTINGS, AND ACCESSORIES. COORDINATE WITH GENERAL CONTRACTOR. PROVIDE AND INSTALL NEW WATER CLOSET (WC-1), WAX GASKET, WATER RISER, 1 4 TURN SHUT-OFF VALVE, AND NEW TOILET SEAT WITH LID. REMOVE EXISTING LAVATORY, TRAP, WASTE, WATER SUPPLY RISERS, AND SUPPLY VALVES. REMOVE WASTE AND WATER PIPING TO WALL. REMOVE EXISTING TUB/SHOWER, VALVE, WASTE, AND TRIM. COLLECT REFRIGERANT PRIOR TO ANY DEMOLITION WORK. DISCONNECT REFRIGERANT LINES FROM CONDENSING UNIT AND COIL AT INTERIOR. REMOVE FOR INSTALLATION OF NEW LINE SET. DISCONNECT AND REMOVE EXISTING COIL AT EXISTING FURNACE. TAKE CARE NOT TO DAMAGE EXISTING FURNACE AND SHEET METAL TRUNK DUCT. REMOVE FURNACE BY UNIT PRICE 'B'. REMOVE AND DISPOSE OF EXISTING CONDENSING UNIT AT EXTERIOR. COORDINATE WITH ELECTRICAL SUBCONTRACTOR FOR DISCONNECTION AND REMOVAL OF ELECTRICAL WHIP. REMOVE EXISTING THERMOSTAT. DISCONNECT EXISTING FLUE AND VENT PIPING TO FURNACE AS NECESSARY TO ALLOW ACCESS TO COIL. DISCONNECT AND REMOVE EXISTING CONDENSATE LINES. REMOVE SHEET METAL CLOSURE PANEL. TURN OVER TO PHA. PROVIDE AND INSTALL NEW WALL-HUNG LAVATORY, FAUCET, TRAP, WASTE, 1 4 TURN SHUT-OFF VALVE, AND WATER RISERS. INSTALL WITH STEEL HANGER. EXTEND EXISTING WATER SUPPLY LINES AND MODIFY WASTE AND VENT LINES TO NEW LOCATION. RUN WATER SUPPLY PIPING IN PARTITIONS TO FIXTURE LOCATIONS. INSTALL SHOWER PAN PROVIDED BY GENERAL CONTRACTOR. PROVIDE AND INSTALL NEW A.D.A. COMPLIANT SHOWER VALVE AND HANDHELD SHOWER. COORDINATE LOCATION OF VALVE BODY WITH GENERAL CONTRACTOR AND U.F.A.S. REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS. INSTALL UNDER SLAB SCHEDULE 40 PVC SANITARY LINE AND VENT TO NEW SHOWER PAN. CONNECT NEW SANITARY LINES TO EXISTING. ROUTE VENT LINES UP INTERIOR OF PARTITION TO ATTIC SPACE AND CONNECT TO EXISTING VENT THROUGH ROOF. EXISTING KITCHEN SINK TO REMAIN. EXISTING WATER HEATER TO REMAIN. COORDINATE WITH ABATEMENT SUBCONTRACTOR FOR DISCONNECTION TO ABATE FLOOR TILE AND MASTIC BELOW HEATER. RECONNECT AS NECESSARY. NEW BATHROOM EXHAUST FAN FLUSH IN CEILING, COORDINATE WITH ELECTRICAL CONTRACTOR FOR ELECTRICAL CONNECTIONS. CONNECT EXHAUST DUCT TO EXISTING ROOF CAP. COORDINATE LOCATION AND INSTALLATION WITH WITH GENERAL CONTRACTOR. NEW COOLING COIL ON TOP OF EXISTING GAS FIRED FURNACE. COOLING COIL SHALL BE CC-1. MODIFY DUCT WORK AS NEEDED TO EXTEND TRUNK TO NEW COIL. SEE DETAIL AND SCHEDULE THIS SHEET. NEW OUTDOOR CONDENSING UNIT ON NEW CONCRETE PAD. CONDENSING UNIT SHALL BE CU-1. SEE SCHEDULE BELOW. COORDINATE WITH GENERAL CONTRACTOR FOR CONCRETE PAD. NEW REFRIGERATION PIPING. PIPING TO RUN FROM CONDENSING UNIT, UP OUTSIDE WALL, THRU SOFFIT, INTO ATTIC, THEN OVER TO ABOVE EXISTING FURNACE, THEN DOWN THRU CEILING TO NEW COOLING COIL. PROVIDE REFRIGERANT LINE COVER SET AT EXTERIOR WITH 90 ELBOW AT ENDS. EXISTING THERMOSTAT TO BE REPLACED WITH NEW AS SPECIFIED. RELOCATE TO 44" A.F.F. TO CENTER. REPLACE THERMOSTAT WIRING TO FURNACE WITH NEW. INSTALL CONDENSATE PUMP AND NEW LINE AT FROM NEW COIL TO EXTERIOR. ROUTE UP FURNACE TO FURRED SPACE, ROUTE THROUGH FURRED SPACE TO CORNER OF CLOSET AND DROP TO EXISTING WALL PENETRATION. SEAL ALL AROUND NEW DRAIN LINE AT INTERIOR AND EXTERIOR. RE-CONNECT EXISTING EXHAUST FLUE, ETC. AS NECESSARY. PLUMBING AND MECHANICAL PLANS UNIT 91 MEP-2 3

1. FIELD VERIFY EXISTING CONDITIONS AND MAKE MINOR ADJUSTMENTS AS NECESSARY. NOTIFY ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 2. COORDINATE DEMOLITION WORK WITH ALL SUBCONTRACTORS. COORDINATE MECHANICAL, ELECTRICAL AND PLUMBING DEMOLITION WITH MEP SHEETS. 3. COORDINATE WITH PHA REGARDING SALVAGE RIGHTS OF REMOVED ITEMS. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, HAULING, AND LEGAL DISPOSAL OF ALL PRODUCTS, EQUIPMENT, AND MATERIAL MARKED FOR DEMOLITION. 5. ALL EXISTING LIGHTING FIXTURES, SWITCHES, RECEACLES, AND OTHER WIRING DEVICES TO REMAIN UNLESS NOTED OTHERWISE. REMOVE INTERIOR COMPONENTS FROM PANEL AS NECESSARY TO RE-USE AS A JUNCTION BOX TO NEW PANEL LOCATION. REMOVE EXISTING DEVICES, BOXES, AND WIRING AT PARTITIONS TO BE DEMOLISHED. REMOVE AND DISPOSE OF EXISTING LIGHT FIXTURE, BOX, AND WIRING. REMOVE AND DISPOSE OF EXISTING HEAT LAMP AND WIRING. REMOVE AND DISPOSE OF EXISTING DOOR CHIME AND WIRING. REMOVE AND DISPOSE OF EXISTING LIGHT SWITCH, BOX, AND WIRING. REMOVE EXISTING GFCI RECEACLE. REMOVE AND DISPOSE OF EXISTING TELEPHONE JACK. EXISTING OUTLET CABLE TO REMAIN. 1. CONTRACTORS SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND MAKE ADJUSTMENTS AS NECESSARY TO WORK WITH EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES WHICH MAY AFFECT THE OUTCOME OF THE WORK. 2. REMOVE EXISTING ELECTRICAL DEVICES AND SWITCHES AS NOTED. REWIRE AS INDICATED ON ELECTRICAL PLANS. 3. ELECTRICAL SUB-CONTRACTOR SHALL COORDINATE ALL WORK WITH GENERAL CONTRACTOR. 4. THE LAYOUTS SHOWN ON THESES DRAWINGS ARE NECESSARILY DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION WILL PERMIT. CHANGES FROM THESE DRAWINGS REQUIRED TO MAKE WORK CONFORM TO EXISTING BUILDING CONDITIONS SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST TO THE PHA, BUT ONLY WITH PRIOR APPROVAL OF THE ARCHITECT. ALL NEW EQUIPMENT SHALL CONNECT TO EXISTING SERVICES UNLESS NOTED OTHERWISE. PROVIDE FOR ANY NECESSARY MODIFICATIONS OR TRANSITIONS OF EXISTING SERVICES. ALL ELECTRICAL DEVICES MAY NOT EXIST IN LOCATIONS INDICATED - CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS. 5. CONTRACTORS SHALL BE RESPONSIBLE FOR REMOVAL, HAULING, AND LEGAL DISPOSAL OF ALL PRODUCTS, EQUIPMENT, AND MATERIAL. 6. ALL ELECTRICAL WORK TO BE PERFORMED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (CURRENT EDITION) AND ALL LOCAL ELECTRICAL CODES. 7. EXISTING THERMOSTAT TO BE RELOCATED - TAKE CARE NOT TO DAMAGE. 8. ALL CIRCUIT CONDUCTORS SHALL BE #12 GA. MINIMUM UNLESS INDICATED OTHERWISE. ALL CIRCUITS SHALL BE CONCEALED. EXISTING PANEL - REMOVE INTERIOR COMPONENTS AND RE-USE AS JUNCTION BOX. EXTEND EXISTING PHASE AND GROUND WIRES AND CIRCUITS TO NEW LOAD CENTER LOCATION. MATCH EXISTING WIRE SIZES. PROVIDE NEW FLUSH COVER AND SECURE TO EXISTING BOX. LABEL AS "JUNCTION BOX". PROVIDE AND INSTALL NEW 20AMP, 120V GFCI RECEACLE/WALL SWITCH COMBO AT EXISTING RECEACLE LOCATION. CONNECT TO EXISTING UNDER CABINET LIGHT TO REMAIN WITH NEW CONDUCTORS CONCEALED IN WALL. RELOCATE RECEACLE FOR NEW WALL CABINET. PROVIDE AND INSTALL NEW GFCI RECEACLE AND BOX - MODIFY CONDUCTORS AS REQUIRED TO RELOCATE RECEACLE FOR NEW CABINET. COORDINATE WITH GENERAL CONTRACTOR FOR WALL PATCH. NEW LIGHT FIXTURE AS SCHEDULED. MODIFY EXISTING CONDUCTORS AS REQUIRED AND RELOCATE FIXTURES DUE TO NEW PARTITIONS. PROVIDE AND INSTALL EMERGENCY PULL STATION AT 44" ABOVE FINISH FLOOR. CONNECT TO EMERGENCY ALARM SYSTEM. COORDINATE EXACT LOCATION OF PULL STATION WITH ARCHITECT PRIOR TO INSTALLATION. SEE DIAGRAM, THIS SHEET. NEW WALL MOUNTED LIGHT FIXTURE WITH BOX ABOVE MEDICINE CABINET. COORDINATE HEIGHT WITH GENERAL CONTRACTOR. LOCATION OF NEW LOAD CENTER (PANEL P1). NEW LOAD CENTER SHALL BE RECESSED IN METAL STUD WALL. SEE SCHEDULE, THIS SHEET FOR CIRCUITING. MOUNT PANEL SO ALL BREAKERS AND MAIN BREAKER DO NOT EXCEED 48" ABOVE FLOOR. MODIFY EXISTING TELEPHONE OUTLET CABLE AS REQUIRED AND CONNECT TO NEW TELEPHONE JACK. NEW JACK TO BE MOUNTED AT 15" A.F.F. TO BOTTOM. EXISTING 2P30 AMP FUSIBLE DISCONNECT TO REMAIN. FLEX TO UNIT WITH (2) #12'S WITH GROUND IN 3 4" PVC COATED FLEXIBLE CONDUIT ON THE LOAD SIDE. EXISTING (2) #12'S WITH GROUND TO EXISTING PANEL ON THE LINE SIDE TO REMAIN. CONNECT TO NEW 2P20 AIR CONDITIONING BREAKER IN NEW PANEL. PROVIDE AND INSTALL BOX, EMERGENCY HORN, AND STROBE LIGHT. MOUNT ON WALL AT CEILING. CONNECT TO EMERGENCY ALARM SYSTEM. SEE DIAGRAM ON THIS SHEET. 2 POLE RELAY/ENCLOSURE LOCATED ON WALL AT CEILING IN LAUNDRY. DOOR BELL AUDIO/VISUAL ALERT SYSTEM PANEL, MOUNT 36" TO CENTERLINE ABOVE FINISH FLOOR. BED VIBRATOR RECEACLE FLUSH IN WALL. (MOUNT AT 15" A.F.F. TO BOTTOM, MINIMUM) MATCH EXISTING. NEW 20 AMP GFCI DUPLEX RECEACLE AND PLATE BETWEEN CABINET AND COUNTERTOP IN KITCHEN NEW 20 AMP GFCI DUPLEX RECEACLE AT 42" A.F.F. IN BATHROOM. NEW DUPLEX RECEACLE WITH PLATE AND BOX AT 30" A.F.F. NEW EMERGENCY ALARM BED VIBRATOR RECEACLE NEW SINGLE POLE LIGHT SWITCH, 120 VOLT RATED INCLUDING SINGLE GANG PLATE AND BOX - MOUNT AT 44" ABOVE FINISH FLOOR TO BOTTOM (42" AF.F. IN BATH) SAME SWITCH AS SPECIFIED ABOVE BUT SHALL BE TWO GANG NEW CEILING MOUNTED LIGHT FIXTURE (TYPE NOTED - SEE LIGHT FIXTURE SCHEDULE) NEW WALL MOUNTED LIGHT FIXTURE (TYPE NOTED - SEE LIGHT FIXTURE SCHEDULE) NEW TELEPHONE JACK AND PLATE EXHAUST FAN/LIGHT BY MECHANICAL SUBCONTRACTOR - CONNECT TO NEW CONDUCTORS BACK TO SWITCH REINSTALL EXISTING THERMOSTAT, INSTALL AT 48" TO TOP OF T-STAT COORDINATE WITH MECHANICAL SUBCONCTRACTOR NEW LOAD CENTER NEW EMERGENCY CALL SYSTEM PULL STATION - SEE PULL STATION DIAGRAM, THIS SHEET. NEW SMOKE DETECTOR WITH STROBE AT EXISTING LOCATION - SEE EMERGENCY ALARM SYSTEM DIAGRAM, THIS SHEET. NEW COMBINATION SMOKE/CARBON MONOXIDE DETECTOR. DOOR BELL SYSTEM STROBE LIGHT/BUZZER @ 48" AFF TO TOP. EMERGENCY CALL SYSTEM HORN/STROBE LIGHT @ 84" AFF. NEW SWITCH AND PLATE TO REPLACE EXISTING. REUSE BOX. DOOR BELL PUSH BUTTON @ 40" AFF. ELECTRICAL PLANS UNIT 91 MEP-3 3