Submersible Pumps AL

Similar documents
SUBMERSIBLE ELECTRIC PUMPS

VOGEL - Submersible Pumps in Stainless Steel Design TVS

SUBMERSIBLE ELECTRIC PUMPS

10" Submersible Pump General Data

Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB

Flygt 3045, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification

SD/SW/VS50 SD50 SW50 VS50

VSS S U B M E R S I B L E S E W A G E P U M P S

N-pump, Standard Motor

HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

Flygt 3057, 50Hz. Technical Specification

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

SHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

HPGR200 2 HP. Capacity-U.S. G.P.M.

Series Sump and Sewage Systems

University of Delaware

NUCLEAR POWER CORPORATION OF INDIA LTD TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 REV NO : 0 DATA SHEET A

SUGGESTED SPECIFICATIONS Pump Frames through 64132

Quality First! Independent Water Pumping Systems. SDSP Submersible Sump Pump

SECTION SLUDGE HOLDING TANK DECANTER PUMP

SK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M.

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

SPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

Flygt 3171, 50Hz. Technical Specification

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

Flygt C-pumps Submersible waste and raw water pumps

TECHNICAL BROCHURE BBLASTER. Filtered Effluent Pump

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

University of Delaware

SUBMERSIBLE SEWAGE EJECTOR

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

Series description Wilo-Drain STS 40

SUGGESTED SPECIFICATIONS

Rugged, reliable and efficient sump pumps... your assurance of a dry basement!

Submersible Axial Flow Propeller Pumps

DEVELOPMENT OF DOWNHOLE PUMP FOR BINARY CYCLE POWER GENERATION USING GEOTHERMAL WATER

C o l u m n S u m p P u m p s

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

HYPER EFFICIENT SOLAR WATER PUMPING SYSTEMS SERIAL 8000 STAINLESS STEEL 100% up to 110 m3 water per hour and up to 295 m head (967 ft)

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

Products II 1 VERTICAL LINE SHAFT PRODUCT AND OIL LUBRICATED PUMPS II 2 SUBMERSIBLE PUMPS II 3 MIX FLOW PRODUCT AND OIL LUBRICATED PUMPS

Submersible. Issue 2 / De-watering and Drainage, Sewage, Industrial and Agriculture. We have submersible pumps for every application.

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

Technical Specification _3.0. Flygt Hz

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

CombiSump. Sump pump

INSTALLATION INSTRUCTIONS

2. Water Pressure Booster Systems. 3. Duplex Pedestal Type Sump Pumps.

EC medium pressure axial fans.

ANDRITZ pumps and motors Products, systems, applications

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

Technical specification. Submersible pump B 2125, 60 Hz

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

SECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS

SECTION INFLUENT EQUALIZATION TANK PUMPS

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

SECTION PACKAGE BOOSTER PUMP STATIONS

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Technical specification

Model EVMS Vertical Multistage Pumps for the Global Market

CombiSump. Vertical long shaft sump pump,according to ISO 2858,EN 733 (DIN 24255), API 610

MODEL 16ASX T/S - SPECIFICATION

Goulds Two Stage, Horizontally Split Case Pump

MODELS PH PH PH

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203

t y p e V S A S E W A G E P U M P

NGO S SEMINAR BOREHOLE PUMPS

griswold EF&G Heavy Duty end suction

RAJKOT ENGINEERING SALES CORPORATION , PARK ROAD, TARAPET, VIJAYAWADA (A.P.) Vijayawada /12/2013

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals.

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

T Series. Self-Priming Centrifugal Pumps

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302

STAINLESS STEEL SUBMERSIBLE PUMPS

HYDRO SERIES 11K2-15K2 LIMITS TO USE

EC medium pressure axial fans. The efficient system solution.

MODEL INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Wilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps. Engineering Specification

B. Wiring Diagrams: For power, signal, and control wiring.

JDL Submersible Grinder Pumps TABLE OF CONTENTS Project: Model: Chk d: Date:

CREATING POWER SOLUTIONS. Hatz Pumps. Hatz Systems Made in Germany.

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Company profile WORKING FOR AN ESSENTIAL RESOURCE MEANS TAKING CARE OF THE FUTURE. w w w. r o v a t t i. i t

HCP Product Introduction

Index - Section 40M Medium Sump / Drainage Pumps Bulletins 4508

DIVISION 15- MECHANICAL Section Fire Pumps

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

Pump Division MSX Solids-Handling, Submersible Pumps

KRS DEWATERING PUMPS

CORROSION-RESISTANT PUMPS.

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Transcription:

Submersible s AL 6-8 - 10-14 It It is is valuable as water

Second lake of Turkey is from Alarko Alarko, presented a lake as big as Van Lake to Turkey by its produced submersible pumps more than.000 since 1974. pumps are UNIQUE INDIVIDUAL and UNINTERRUPTED WATER SOUCE in potable water status by everytime being ready to use, with no trouble and with short reimbursement term. pumps are PROPER INVESTMENT in providing using water and process water in industrial facilities and administrations because of high efficiency and long life period. pumps are MULTIFUNCTIONAL because of usable for from detached houses to skyscrapers and because of obtained advantage using it as a water stocking hydrophore. pumps are RELIABLE FRIENDS of garden lovers and farmers on horticulture, agriculture and from little house garden to agricultural land as thousands acres. pump is a UNIQUE RELIABLE WATER SOURCE for touristic facilities, which especially need more water in tourism term. pumps are PREEMINENT because of high technology economy continual and quality service quick procurement of spare part. ALARKO IS ALWAYS THE FIRST ON SUBMERSIBLE PUMP*. * In Turkish pump market.

PUMP SELECTION Applications l Water supply in towns and rural areas. l Sprinkling - irrigation. l Water pressurisation in all buildings industrial water supplies. l Water fountains. l And for all general pumping of clear water from standard sink and bore holes. Advantages l It does not have to be protected from open air conditions because motor works in the well water. l No limitation for the depth of immersion. It can be come down to deep as total head. l Any special tube or tool is not required. l There is not fan adjustment problem. l Shaft cutting or oil lack is not experienced. l Mounting is easily and there is not any axle alignment problem. l It is silent. l It is not effected well inclines as pump with perpendicular shaft. l For HP motors, facility of open 6 well instead of 8 well H(mWc) 0 4 400 3 300 2 200 110 6010 6010 6015 6011 6015 6011 6022 6024 6020 8028 603 Application Limits l According to pump nominal diameters; first four series as 6, 8, 10, 14 l Total 29 models and 816 types between 2 and 180 HP 6020 6024 6022 6 DESIGN l Multistage centrifugal pump. l shaft, coupling, suction stainer bearing sleeve and external housing sleeve (for 6010-6015-6020-6031 types), casing wear ring (for 6010-6015-6020-6031-8028-8048 types) are made of stainless steel. l Radial Noryl impellers and diffusers for small flows, semiaxial cast-iron or bronze impellers and diffusers for large flows l Sliding bronze bearings or rubber bearings cooled and lubricated by well waetr. l Max. operating time at closed valve position is 5 min. l Water filled and cooled squirrel cage type. l Wet stator windings insulated PVC, PP or XLPE. l Graphite radial and axial bearings and stainless steel bearing pads. l Stainless steel motor external housing and rotor shafts for 6 & 8 motors. l Carbon steel motor external housing and heat treated steel rotor shafts for 10 motors. l Supply voltage: 3 phase 380 V, hz. l Shaft extensions & axial load carrying capacities are according to NEMA standards. 0 0 10 20 It is determined that requested intersection point (A) of flow and manometer height is remained in which pump s area from General Selection Abac In order to select pump, its Independent Characteristic Curve is checked Level number on the upper nearest curve to intersection point of flow and manometer head. According to determined pump type and level, motor type and power are defined from Electrical Specifications, Dimensions and Weight Table according to Order Notation is demanded from Alarko Carrier vendor with determining electrical switchboard demand and electrical cable length.

8131 8048 8045 8131 Brf 6031 8028 8090 101 10180 8075 8125 6055 6045 10200 10216 A 143 8048 140 6031 140 143 6045 8045 8131 Brf 10180 10216 6055 8075 8090 8125 8131 101 10200 30 40 60 70 80 90 1 200 2 300 3 400 4 0 5 Q (m 3 /hour) Selection Sample Assume that Well diameter is 8 5/8, flow (Q) is 30 m 3 /h and manometer height is (H) 110 mwc. On General Selection Abac" 30m 3 /h at the horizantal axle and 110 mwc at the vertical axle are intersected. Intersection point (A), is stayed in 6031 type pump area. From this area, it is passed to Independent Characteristic Curve of 6031 type pump. The intersection point of 30 m 3 /h and 110 mwc is near to 12nd level (stage). level is selected as 12. efficiency is 65%. type and motor power is found as AL 6-20 from Electrical Specifications, Dimensions and Weight Table Order notation is determined as 6031-12+AL 6-20 Sample Curve (6031) H (mwc) 300 2 200 1 110 A NPSH 8 (mwc) 8 5 4 NPSH 6 4 0 2 15 19 23 27 31 35 39 43 Q μp(%) 70 65 60 55 27 22 18 14 12 0 15 19 23 27 31 35 39 43 Q μp 5 6 7 8 9 10 11 12 Q P P(HP) 2 1

CONTROL PANEL Cable Selection (%3 Voltage Drop) Available parts in the standard electrical switchboard: Energy Control Lamp: It shows whether if power supply is available or not in the switch board. Main switch: It switches on the power supply of switchboard. Control Switch: It directs motor. Water Level Automat: It controls pump entrance and exit to circuit according to well water level. It prevents pump works without water. Water level automat, level control electrode and electrode cable group are present as a set. Phase () Control Relay and Warning Lamp: It prevents motor staying with two phase at three phase motors. On the other hand, it provides a protection via stopping the pump while phase imbalance in the network. Fuses: Protection to short circuit. Thermal Relay: Protection to overload Warning Lamps: Malfunction, Run, Well is drought lamps. It enables monitoring of pump running easily. Ammeter and Voltmeter: Current and voltage values can be measured by them. Nominal Gerilim Tek Fazl 220 V 3 Fazl 380 V Gücü kw HP 0,37 0,5 0,55 0,75 0,75 1 1,1 1,5 1,5 2 0,37 0,5 0,55 0,75 0,75 1 1,1 1,5 1,5 2 2,2 3 3 4 3,7 5 4 5,5 4,4 6 5,5 7,5 7,5 10 11 15 15 20 18,5 25 22 30 30 40 37 45 60 55 75 70 96 80 110 96 130 110 1 132 180 Kablo Kesiti (mm 2 ) 4x1.5 4x2.5 4x4 4x6 4x10 3x16+10 3x25+16 3x35+16 3x+25 3x70+35 3x95+ 80 133 212 316 520 58 42 35 25 545 347 296 199 155 108 80 70 62 45 96 69 55 41 575 490 331 257 180 133 125 104 82 75 1 110 91 66 528 411 287 213 186 166 160 119 226 164 136 98 612 429 317 290 248 178 372 271 164 121 707 522 420 400 260 293 645 60 95 145 245 390 40 66 170 275 30 75 130 205 35 60 90 155 245 30 75 130 205 55 95 155 45 75 125 65 80 65 5 610 855 430 605 325 390 325 195 160 130 85 455 545 455 340 275 225 180 140 120 85 6 780 6 485 390 325 260 205 170 145 125 105 680 5 455 365 285 205 175 145 925 745 620 495 390 330 275 200 s 25 HP and over are star delta. In star delta motor, selected cable from the upper table will be used 2 quantities. Do not use the above table with soft starter.

FOR SECURE AND EFFICIENT USES l Well water temperature and sand ratio in the well water should be controlled in the laboratory. Maximum sand in the well water should be gr/m 3 and well temperature should be 30 C. l Pipes and Pipe clamps should have durability as carrying water in the vertical tube, tube group and itself weight. l It is recommended that well diameter is bigger than pump diameter as at least 2 (inch). l Distance between pump suction filter and well filter should be maximum. l Distance between the bottom end of the motor and base of the well should be at least cm. Length of pump in the well is determined due to this measurement. l Since pump does not suck air, pump assembly depth should be proper to Net Positive Suction Height (minimum depth it can work at) values. Application Methods Placing within a wide well H= 0,3 m (If B+9>NPSH) H= NPSH-(B+9) (If B+9<NPSH) B: Length Manometer Energy Cable Placing within a normal well Manometer Air Conditioning Valve Control Switchboard Energy Cable Placing within a large well Air Conditioning Inlet cover Well cover Manometer Connection Well inlet flange Valve Profile Electrode Delivery Pipe Electrode Protective pipe Delivery Pipe Delivery Pipe cm H Cable will be knotted A Electrical Cable Cable Clamp Check-Valve 300 H cm Electrical Cable Cable Clamp Check-Valve Electrical Cable Cable Clamp Check-Valve Suction Stainer Suction Stainer Suction Stainer Filter DETAIL-A Pebble stones Pebble stones Alarko Carrier Sanayi ve Ticaret A.fi. Submersible Experiment Laboratory was accredited by TÜRKAK (Turkey Accreditation Foundation) on 28/03/2006. This laboratory is the first laboratory which was accredited in submersible pump industry for clean water in our country. Order Notation 6 031 / 12 + AL6-20 -T. 60 Electrical cable length (m) T: Has electrical control panel Y: Has no electrical control panel Type Number of impeller (stage) Max Flow point at the efficiency (m 3 /hour) outher diameter pumps are shipped as securely packaged from factory. There are Allen wrench, water freeze funnel and locktite. in the packages of 6, 8, 10, 14 submersible pumps. Control switchboard, water level control electrode and cable are optional. If it is requested, the yare delivered in a second package. The company reserves its right to alter its products due to technological developments ALARKO CARRIER SANAY VE T CARET A.fi. GOSB-Gebze Organize Sanayi Bölgesi fiahabettin Bilgisu Cad. 41480 Gebze/Kocaeli/TURKEY Phone : +90 262 648 60 00 PBX Telefax : +90 262 648 61 01 web : www.alarko-carrier.com.tr e-mail : info@alarko-carrier.com.tr D.1.1.1 i 108 MiNERAL