Home Inspection Report

Similar documents
All Pro Home Inspection. Home Report North Your Town

Inspection Report. Property Address:

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

Alabama Home Inspections

All Pro Home Inspection. Home Report South Your Town

component was performing its intended function; installation and condition were appropriate for age and use.

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

The Inspector. Property Inspection Report

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011

Friendly Inspection Services

Building Inspection Report

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017

Home Inspection Report

Friendly Inspection Services

Home Inspection Report

Hawks Eye Home Inspection LLC. Shoreline, Wa Williams Rd. Renton, Wa 98057

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6

1234 Main St. Buyer Name. Table of Contents

Property Inspection Report

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012

Pacific Inspection Group Keaau-Pahaoa Rd Keaau, Hawaii Somewhere In Paradise Keaau, Hawaii 96749

REPORT CHECKLIST SUPPLEMENT

Report Page 1 of 23 12/30/2013 Tri-City Home Inspections James Eddy ID:

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012

The Home Doctor, Inc.

1st Defense Home Inspections, LLC

Hogue Home Inspections

Inspection Report. 1 of 8

6954 Lakeside Dr. Property Inspection Report. - Provided by First Class Property Inspections, LLC -

Friendly Inspection Services

Rental Inspection Checklist

Madison's Home Inspections

1234 Main St Denver CO 80210

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Inspect Hawaii. Property Inspection Report

JM Rodkey, Co., Inspections

Safety Money Repair Maintenance Evaluate Monitor Comment

Home Inspection Report. LH Home Services Edgewater McCall, Idaho

Weaver Home Inspections, LLC 181 Chase Rd. Columbus, Oh Home Inspection Report

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

Home. Safe. Home. home inspection report

Tru-Quest Home Inspection

Inspection Report. Provided by: Cummins Services LLC. Inspector: Bill Cummins. Phone:

HOME INSPECTION REPORT Prarie Circle

3D Home Improvement and Inspection Services, Inc

Applecore Inspections, LLC

Property Inspection Checklist

WEST MICHIGAN HOME INSPECTORS LLC 3134 Chamberlain SE Grand Rapids MI

Advanced Home Inspections

Wednesday, November 6, Mrs. x

Property Inspection Report

Pre-Listing Home Inspection Checklist

Property Inspection Report

Inspection Xpress. Property Inspection Report

Inspection Services of the Treasure Coast

Property Inspection Report

Home Inspection. Happy Home Buyer 125 Happy Lane Anytown TN The date of the inspection

Inspection Report. Property Address: 908 Black Hills Drive Spearfish, SD 57783

L&A Home Inspections

Pinnacle Home Inspections, Inc. Serving Central Arkansas

Integrity Home Inspection & Testing, LLC

JBR Property Inspections

The Home Buyers Protection Company

G. Warren, Inc. Metuchen, NJ Definitions

$308,900. Caleb Crescent Collection The Algonquin Model 1113 Sq. Ft. Elevation A. Updated: September 28, Elevation B

Total Home Inspection Checklist

NEV-CAL Home Inspections

Building Inspection Report

Ottawa Inspections Inspection Report

A Summary of the Basic Duties of Maintenance, Repair and Replacement for CARRIAGE PARK CONDOMINIUM ASSOCIATION

FAIRA TRANSPARENCY REPORTS th Ave SE, Puyallup, WA July 10 th, 2017

Calidad Home Inspection Colleyville, TX (817) /

The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits

InterNACHI Home Inspection Report Checklist

Home Inspection. 123 Main St Anywhere, USA Prepared for: Happy Homeowner Prepared by: Blue Crab Inspections

Date of Inspection: April 30th 2006 Client: Ivan M. House Inspector: Lee Ottewell (CPBC License #: 47384)

J & M Solutions, LLC

City of Maryland Heights. Residential Occupancy Permits & Home Inspection Process

SNS Home Inspections LLC

Capstone Inspection Services LLC

SINGLE FAMILY HOME SPECIFICATIONS

SAMPLE Property Inspection Report

Assurance Building Inspections, LLC

Client: Address: Inspection Date: 07/31/2011 Inspection Time: 10:00 A.M. 12:30 P.M. Weather Conditions: Overcast, 65 deg F +-

Mountain View Home Inspections

Home Condition Checklist

A 1 Professional Home Inspection 14 Brevoort Pl. Deer Park, NY Jamaica, NY 11434

Home Inspection Report

Accurate Inspections Inc. Property Inspection Report

HOME MAINTENANCE GUIDE KEEPING YOUR HOME IN EXCELLENT CONDITION

Lacroix Home Inspection LLC th. NW Gig Harbor, WA 33e333. Inspection of. xxxxx 000St. NW Somewhere, oo

HomeOwner Services, Inc.

Ohio Home Inspection Organization

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

Red Rock Home Inspections

V.I. Inspections Drew and Marsha Murphy Palatine Ave N.

Transcription:

Home Inspection Report Example Home Inspection Report.

Page 1 of 17 Table of Contents Definitions 2 Company Information 2 General Information 2 Lots and Grounds 3 Exteriors 3 Garage/Carport 4 Roof 5 Attic 6 Interiors 7 Appliances 8 Structure 9 Electrical 9 Plumbing 11 Heating System 12 Air Conditioning 13 Summary 14

Page 2 of 17 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection Acceptable Functional with no obvious signs of defect. Note Refer to Note section for further explanation of item. Partial Inspection Item was not able to be fully viewed due to limitations. Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. Not Tested Item, component, or system not tested using normal operating controls. Not Present Item not present or not found. Marginal Item is not fully functional and/or requires repair or servicing. Defective Item needs immediate repair or replacement. It is unable to perform its intended function. Company Information 1. Inspector Name Cody Wright 2. Company Name General Information Property Inspected: Example Home Inspection Report. Inspection Date: June 1, 2020. Clients: John Doe. Client Phone: 555-5555 Client Email: johndoe@examplereport.com Client Mailing Address: 123 Anywhere St. Cody Wright, Licensed Home Inspector, Consumer Protection BC License No. 66639 Phone: 250-462-8946 Email: contact@synergyhomeinspections.ca Website: www.synergyhomeinspections.ca Property Occupied: Yes. Building Type: Single family. Space Below Grade: Basement. Note: This report resembles a Home Inspection Report produced by. This report is used as an example only. Not to be reproduced.

Page 3 of 17 Lots and Grounds 1. Note Driveway: Concrete. 1. Cosmetic Item: Cracked concrete noted. This is a normal condition of concrete. Monitor. 2. Acceptable 3. Note Decks: Sheet vinyl, limited by stored items. Railings: Metal. 1. Tip: For added safety, install a guardrail on the north west section of the driveway where there is a drop off. 4. Note Grade: Height. 1. Maintenance Tip: To help reduce moisture damage to siding, lower grade height where the stucco is in contact with the soil. Exteriors Main Exterior Surface 1. Method of Inspection: From ground level, From the decks. 2. Note Type: Stucco. 1. Maintenance Item: To help prevent moisture damage, repair cracked and loose stucco on the north west corner of the home. 3. Note Exterior Doors: Metal with glass, vinyl double glazed patio sliders. 1. Maintenance Item: Both the main floor south sliding door and the master bedroom sliding door did not lock shut. Recommend repairs. 2. Maintenance Item: Torn screen door. Repair.

Page 4 of 17 Exteriors (Continued) Exterior Doors: (continued) Not latching 4. Note Not Latching Torn screen Caulking & Sealing: Gaps and Penetrations. 1. Maintenance Tip: To help prevent moisture damage and/or insect entry, caulk around exterior wall penetrations (e.g. communication cables, pipes, etc.), and at gaps where the stucco meets the side of the foundation (south side). Garage/Carport Main Garage 1. Type of Structure: Attached 2. Note Service Doors: Metal. 1. Safety Tip: The door separating the house and garage has a spring hinge, however the door does not close by itself. Ensure that the door self-closes; this is helpful for keeping harmful vehicle exhaust out of the home. Adjust spring hinges. 3. Acceptable 4. Acceptable Walls: Drywall, inspection limited by stored items. Floor: Concrete, inspection limited by stored items.

Page 5 of 17 Garage/Carport (Continued) 5. Note Walls, Doors, Ceilings Separting House & Garage: Gaps and penetrations. 1. Safety Tip: Gaps noted at walls/ceilings and penetrations. All gaps and penetrations in walls and ceilings attached to the home should be sealed to help prevent vehicle exhaust (carbon monoxide) from entering the home. Also ensure to seal joints in west wall storage shelf. Gaps Gaps at penetrations Seal shelving Roof Every Roof Surface 1. Method of Inspection: On main roof, Ground level, Ladder at eaves. 2. Note Material: Asphalt shingle. 1. Maintenance Item: Damaged shingle noted on the south portion of the roof. Also noted a minor torn shingle above the central roof vent. Recommend repairs by a roofing contractor. 2. Maintenance Item: Proud nail noted on the south east corner of the roof. Repair Torn Proud nail Damaged shingle 3. Estimated Age: Original roof as stated by the owner. 4. Note Plumbing Vents: ABS, inspection limited by structure and finishings. 1. Maintenance Tip: Seal the gap in between the vent pipe and the flashing to help prevent water entry into the attic. Seal

Page 6 of 17 Roof (Continued) 5. Note Downspouts: Metal. 1. Maintenance Item: A hole was noted in the north west downspout. Repair. 6. Note Downspout Leaders: Plastic, only visible above grade. 1. Maintenance Item: Noted a "y" connection at the base of the south west downspout. This connection may allow water to splash back out the connection and settle next to the foundation. Monitor Attic Main Attic 1. Method of Inspection: Partial traverse of the attic. Inspection limited by potential of causing damage. 2. Partial Inspection Framing: Wood trusses, wood i-joist rafters, inspection limited by insulation and accessibility. 3. Partial Inspection Sheathing: Oriented Strand Board, inspection limited by insulation and accessibility. 4. Acceptable Ventilation: Roof vents, Soffit vents, vent chutes, inspection limited by insulation and accessibility. 5. Acceptable Insulation: Blown-in fiberglass, fiberglass batt, inspection limited by accessibility.

Page 7 of 17 Interiors 1. Acceptable 2. Acceptable 3. Acceptable 4. Acceptable 5. Note Walls: Drywall, inspection limited by stored items, furniture and appliances. Floor: Tile, Linoleum, Carpet, inspection limited by stored items, furniture and appliances. Ceiling: Drywall, Suspended ceiling. Doors: Hollow wood, French. Windows: Vinyl double glazed. 1. Maintenance Item: the top floor east window opens only slightly. Repair. 2. Maintenance Item: The east corner window in the main floor office has a failed seal, allowing condensation to form in between the glass panes. This is cosmetic; however, it can be repaired. 3. Maintenance Item: Missing window screen noted. Window opens only slightly Failed seal Missing screen 6. Note Ventilation: Humidistat. 1. Maintenance Item: The humidistat, located in the main floor hallway, did not have any response when operated. A humidistat is used to help regulate the humidity in the home by automatically turning on exhaust fans (e.g. bathroom ceiling fans). Recommend investigation. 7. Acceptable 8. Note Clothes Dryer Ventilation: Dryer hose, vents to the outdoors. Kitchen Ventilation: Main floor rangehood, vents to the outdoors. 1. Maintenance Tip: If a basement kitchen is to be installed, recommend installing a rangehood to help exhaust moist air from cooking. Bathroom Ventilation: Electric ceiling exhaust fans. 1. Maintenance Item: All bathroom ceiling fans respond to controls; however, the inspector was unable to verify if and where the main floor and basement bath fans exhaust to. Investigate. Exhausting warm moist air from the house helps to prevent moisture related problems. 9. Note

Page 8 of 17 Appliances 1. Acceptable Fridge/Freezer: Operational. 2. Note Stove: Main floor kitchen, responds to controls. 1. The basement natural gas stove gas line was not connected, and the stove not tested. 3. Acceptable 4. Acceptable Range Hood: Responds to controls. Microwave: Responds to controls. 5. Acceptable Dishwasher: Responds to controls. 6. Acceptable Washer: Responds to controls. 7. Acceptable Dryer: Responds to controls.

Page 9 of 17 Appliances (Continued) 8. Acceptable Built-In Vacuum: Responds to controls. Structure 1. Partial Inspection Foundation: Concrete, limited by stored items, finishings and grade. 2. Partial Inspection Floor Structure: Wood I-joists, concrete, inspection limited by structure, finishings, stored items and installed systems. 3. Partial Inspection Concrete Floor Slab: Inspection limited by finishings and stored items. 4. Partial Inspection Wall Structure: Wood framed, inspection limited by finishings. 5. Partial Inspection Roof & Ceiling Structure: Wood trusses, wood i-joist rafters, inspection limited by insulation and accessibility. 6. Partial Inspection Subfloor: Plywood, inspection limited by structure and finishings. Electrical 1. Service Amp Rating: 150 Amps, According to the main breaker. Volts: 120/240. 2. Not Inspected Service Entrance Wires: Underground service not visible. 3. Not Tested Main Disconnects: Located at the main panel in the garage. 4. Not Inspected Service Panel Cover: Not removed due to safety regulations. 5. Not Inspected 6. Note 7. Acceptable Service Grounding: Inspection limited by structure and finishings. 120/240 Volt Branch Circuits: Copper, inspection limited by structure and finishings. 1. Electrical Item: The south exterior receptacle is not hard-wired, but rather is supplied by an extension cord that is plugged into a receptacle near the interior main water shutoff. Extension cords are not intended for permanent use and may overheat if used long term. Recommend an electrician to hard-wire an electrical cable to the south exterior receptacle. Wire Types: Non-metallic sheathed cable, Armored cable, Tec cable, inspection limited by structure and finishings.

Page 10 of 17 Electrical (Continued) 8. Marginal 9. Not Tested 10. Marginal 120 Volt Receptacles: 3 Prong grounded. 1. Electrical Item: A receptacle on the west wall in the master bedroom does not appear to be grounded. For shock protection, recommend repairs by an electrician. 240 Volt Receptacles: Not tested by inspector. Exterior 120 Volt Receptacles: 120 Volt, 120 Volt GFCI protected. GFCI receptacle on top deck not tested due to hot tub in use. 1. Maintenance Item: The north east GFCI receptacle is missing a weather cover. Repair. 2. Electrical Item: The north east GFCI receptacle was working intermittently. Recommend repairs by an electrician. 3. Electrical Tip: For increased shock protection, install ground fault circuit protection at the south exterior receptacle that is not currently GFCI. Missing weather cover Receptacle is intermittent Install GFCI for added shock protection 11. Acceptable 12. Acceptable 13. Note Interior GFCI Receptacles: Respond to controls. Door Bell: Respond to controls. Smoke Detectors Present? Yes. 1. Safety Tip: For increased safety, ensure smoke detectors are located in every bedroom and on every floor. Missing detector 14. Marginal Carbon Monoxide Detector(s) Present? None located. 1. Safety Item: Due to the presence of combustion appliances, ensure carbon monoxide detectors are present in the home on each floor for increased safety. Garage Electric Panel 15. Note Panel: Siemens. 1. Maintenance Item: The panel labeling has faded and is difficult to read. Recommend re-labeling by an electrician. 2. Maintenance Item: Missing cover screws. Replace.

Page 11 of 17 Electrical (Continued) Panel: (continued) Re-label panel Missing screws 16. Not Tested Breakers: Not operated due to circuits in use. Plumbing 1. Partial Inspection Supply Line: Painted plastic, inspection limited by structure and finishings 2. Main Water Shut-Off Location: Basement south bedroom closet. Main water shutoff 3. Note Distribution Water Lines: Polybutylene pipe with copper fittings, Copper pipe, inspection limited by structure and finishings. 1. Tip: Polybutylene water pipe with copper fittings noted. This type of pipe, especially when it has been used with plastic fittings (not located in this home), has been known to leak. However, no leaks were noted by the inspector and the homeowner stated that he has not had any issues. Simply monitor. 4. Partial Inspection Drain & Waste Pipes: ABS, inspection limited by structure and finishings. 5. Partial Inspection Floor Drains: Visual inspection, not wet tested. 6. Note Hose Bibs: Frost protected and non-frost protected. 1. Maintenance Tip: Ensure to drain and winterize all non-frost protected hose bibs.

Page 12 of 17 Plumbing (Continued) 7. Marginal Sump/Sump Pump: Sewage sump. 1. Plumbing Item: The inspector ran the water at the basement bathtub, sink and toilet simultaneously to try and activate the sump pump; however, the pump did not automatically start up. The pump only started manually when plugging it into the other receptacle. Recommend further investigation by a plumber. 8. Note Water Heater: Natural gas hot water tank. 1. Maintenance Item: The water heater is nearing the end of its expected life span. Recommend replacing the water heater in the near future to help reduce the risk of tank rupture. 9. Main Fuel Shut-Off Location: Primary: at the gas meter. Secondary: next to the water heater. 10. Approx. Age: 2003. 11. Capacity: 150 L. 12. Acceptable Flue Pipe: Metal, inspection limited by structure and finishings. Heating System Basement Heating System 1. Type: Forced air furnace. 2. Acceptable Heating System: System responds to controls. 1. The furnace is nearing the end of its expected life span. Monitor. 3. Fuel Type: Natural gas. 4. Fuel Shut-Off Location: Primary is at the gas meter. Secondary is next to the furnace. 5. Approx. Age: 1993. 6. Capacity: 102,500 BTUH Output. 7. Not Inspected Heat Exchanger: Not visible, concealed. 8. Partial Inspection Blower Fan: Direct drive, inspection limited by accessibility. 9. Marginal Combustion Air Source: Room air. 1. Safety Item: The furnace and water heater require combustion air that is currently provided

Page 13 of 17 Heating System (Continued) Combustion Air Source: (continued) by the room. Due to the large output of both appliances, there may currently not be sufficient combustion air; this may create carbon monoxide. This can be repaired by installing grills in the door. Recommend review by a heating specialist. 10. Acceptable Exhaust Method: Induced draft. 11. Acceptable Flue/Vent Types: Metal, inspection limited by structure and finishings. Garage Heating System 12. Type: Convection baseboard. 13. Acceptable Heating System Operation: System responds to controls. 14. Fuel Type: Electricity. 15. Acceptable Thermostats: Responds to controls. Air Conditioning Main AC System 1. Type: Central A/C. 2. Acceptable Air Conditioning System: System responds to controls. 1. The A/C is nearing the end of its expected life span. Monitor. 3. Fuel Type: Electricity. 4. Approx. Age: 1993. 5. Partial Inspection Exterior Unit: Inspection limited by housing. 6. Acceptable Thermostats: Responds to controls.

Page 14 of 17 Note Summary Lots and Grounds 1. Driveway: Concrete. 1. Cosmetic Item: Cracked concrete noted. This is a normal condition of concrete. Monitor. 2. Railings: Metal. 1. Tip: For added safety, install a guardrail on the north west section of the driveway where there is a drop off. 3. Grade: Height. 1. Maintenance Tip: To help reduce moisture damage to siding, lower grade height where the stucco is in contact with the soil. Exteriors 4. Main Exterior Surface Type: Stucco. 1. Maintenance Item: To help prevent moisture damage, repair cracked and loose stucco on the north west corner of the home. 5. Exterior Doors: Metal with glass, vinyl double glazed patio sliders. 1. Maintenance Item: Both the main floor south sliding door and the master bedroom sliding door did not lock shut. Recommend repairs. 2. Maintenance Item: Torn screen door. Repair. 6. Caulking & Sealing: Gaps and Penetrations. 1. Maintenance Tip: To help prevent moisture damage and/or insect entry, caulk around exterior wall penetrations (e.g. communication cables, pipes, etc.), and at gaps where the stucco meets the side of the foundation (south side). Garage/Carport 7. Main Garage Service Doors: Metal. 1. Safety Tip: The door separating the house and garage has a spring hinge, however the door does not close by itself. Ensure that the door self-closes; this is helpful for keeping harmful vehicle exhaust out of the home. Adjust spring hinges. 8. Main Garage Walls, Doors, Ceilings Separting House & Garage: Gaps and penetrations. 1. Safety Tip: Gaps noted at walls/ceilings and penetrations. All gaps and penetrations in walls and ceilings attached to the home should be sealed to help prevent vehicle exhaust (carbon monoxide) from entering the home. Also ensure to seal joints in west wall storage shelf. Roof 9. Every Roof Surface Material: Asphalt shingle. 1. Maintenance Item: Damaged shingle noted on the south portion of the roof. Also noted a minor torn shingle above the central roof vent. Recommend repairs by a roofing contractor. 2. Maintenance Item: Proud nail noted on the south east corner of the roof. Repair 10. Plumbing Vents: ABS, inspection limited by structure and finishings. 1. Maintenance Tip: Seal the gap in between the vent pipe and the flashing to help prevent water entry into the attic. 11. Downspouts: Metal. 1. Maintenance Item: A hole was noted in the north west downspout. Repair. 12. Downspout Leaders: Plastic, only visible above grade. 1. Maintenance Item: Noted a "y" connection at the base of the south west downspout. This connection may allow water to splash back out the connection and settle next to the foundation. Monitor

Page 15 of 17 Note Summary (Continued) Interiors 13. Windows: Vinyl double glazed. 1. Maintenance Item: the top floor east window opens only slightly. Repair. 2. Maintenance Item: The east corner window in the main floor office has a failed seal, allowing condensation to form in between the glass panes. This is cosmetic; however, it can be repaired. 3. Maintenance Item: Missing window screen noted. 14. Ventilation: Humidistat. 1. Maintenance Item: The humidistat, located in the main floor hallway, did not have any response when operated. A humidistat is used to help regulate the humidity in the home by automatically turning on exhaust fans (e.g. bathroom ceiling fans). Recommend investigation. 15. Kitchen Ventilation: Main floor rangehood, vents to the outdoors. 1. Maintenance Tip: If a basement kitchen is to be installed, recommend installing a rangehood to help exhaust moist air from cooking. 16. Bathroom Ventilation: Electric ceiling exhaust fans. 1. Maintenance Item: All bathroom ceiling fans respond to controls; however, the inspector was unable to verify if and where the main floor and basement bath fans exhaust to. Investigate. Exhausting warm moist air from the house helps to prevent moisture related problems. Appliances 17. Stove: Main floor kitchen, responds to controls. 1. The basement natural gas stove gas line was not connected, and the stove not tested. Electrical 18. 120/240 Volt Branch Circuits: Copper, inspection limited by structure and finishings. 1. Electrical Item: The south exterior receptacle is not hard-wired, but rather is supplied by an extension cord that is plugged into a receptacle near the interior main water shutoff. Extension cords are not intended for permanent use and may overheat if used long term. Recommend an electrician to hard-wire an electrical cable to the south exterior receptacle. 19. Smoke Detectors Present? Yes. 1. Safety Tip: For increased safety, ensure smoke detectors are located in every bedroom and on every floor. 20. Garage Electric Panel Panel: Siemens. 1. Maintenance Item: The panel labeling has faded and is difficult to read. Recommend re-labeling by an electrician. 2. Maintenance Item: Missing cover screws. Replace. Plumbing 21. Distribution Water Lines: Polybutylene pipe with copper fittings, Copper pipe, inspection limited by structure and finishings. 1. Tip: Polybutylene water pipe with copper fittings noted. This type of pipe, especially when it has been used with plastic fittings (not located in this home), has been known to leak. However, no leaks were noted by the inspector and the homeowner stated that he has not had any issues. Simply monitor. 22. Hose Bibs: Frost protected and non-frost protected. 1. Maintenance Tip: Ensure to drain and winterize all non-frost protected hose bibs. 23. Water Heater: Natural gas hot water tank. 1. Maintenance Item: The water heater is nearing the end of its expected life span. Recommend replacing the water heater in the near future to help reduce the risk of tank rupture.

Page 16 of 17 Note Summary (Continued)

Page 17 of 17 Marginal Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Electrical 1. 120 Volt Receptacles: 3 Prong grounded. 1. Electrical Item: A receptacle on the west wall in the master bedroom does not appear to be grounded. For shock protection, recommend repairs by an electrician. 2. Exterior 120 Volt Receptacles: 120 Volt, 120 Volt GFCI protected. GFCI receptacle on top deck not tested due to hot tub in use. 1. Maintenance Item: The north east GFCI receptacle is missing a weather cover. Repair. 2. Electrical Item: The north east GFCI receptacle was working intermittently. Recommend repairs by an electrician. 3. Electrical Tip: For increased shock protection, install ground fault circuit protection at the south exterior receptacle that is not currently GFCI. 3. Carbon Monoxide Detector(s) Present? None located. 1. Safety Item: Due to the presence of combustion appliances, ensure carbon monoxide detectors are present in the home on each floor for increased safety. Plumbing 4. Sump/Sump Pump: Sewage sump. 1. Plumbing Item: The inspector ran the water at the basement bathtub, sink and toilet simultaneously to try and activate the sump pump; however, the pump did not automatically start up. The pump only started manually when plugging it into the other receptacle. Recommend further investigation by a plumber. Heating System 5. Basement Heating System Combustion Air Source: Room air. 1. Safety Item: The furnace and water heater require combustion air that is currently provided by the room. Due to the large output of both appliances, there may currently not be sufficient combustion air; this may create carbon monoxide. This can be repaired by installing grills in the door. Recommend review by a heating specialist.