BUILDING CODE BULLETIN

Similar documents
Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

Corridor Pressurization System Performance in Multi-Unit Residential Buildings

ASHRAE 62.2: What s New in 2016

ASHRAE 62.2: What s New in 2016

PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT. Construction requirements for LOWER LEVEL DEVELOPMENT. in residential dwellings

Advanced Ventilation for Residential applications FBC Res 2010.

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Section Old G4 February 2014 Amendments to G4

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

PART 9 ENERGY EFFICIENCY AND VENTILATION REQUIREMENTS (For Single and Two Family Dwellings)

ASHRAE and Indoor Air Quality

Illinois Sustainable Technology Center, University of Illinois at Urbana-Champaign

Supplement B - Taking Credit for Reduced Air Leakage in Residential Buildings

Airflow in Mid to High-rise Multi-Unit Residential Buildings

FRAMING INSPECTION GENERAL

Supplementary Standard SB-12. Energy Efficiency For Housing

General Requirements for Mobile Homes

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

BUILDING CODE VARIANCE

How to Prepare Your LSE Report

2018 IRC Sections R303 through R310 Building Planning II

RESIDENTIAL VENTILATION DESIGN FORM (FOR SYSTEMS SERVING A SINGLE DWELLING UNIT ONLY)

Airport Vicinity Acoustic Insulation

National Weatherization Conference. Ventilation Best Practices & airflow verification FIELD RESEARCH. Joe Nagan, Home Building Technology Services

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

NOTE: Some guidance on a performance approach to natural ventilation systems design is provided in the Supplement to this Standard.

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

A.ENVELOPE AIR SEALING

ORDINANCE NO. XXXX BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:

Mark Lawton, P.Eng., FEC. Airtightness in Buildings A Canadian History June 2017

2010 National Building Code Adoption and Associated Process Changes

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

Common Plan Review Rejection Reasons

Common Plan Review Rejection Reasons

Document Reference Number - CL4 CL4FIRE

2012 IRC Sections R303 R310 Building Planning II

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Residential Rental Property Self-Certification Checklist Rental property municipal address Rental Property number Office Use Only License No.

Energy Efficiency Requirements 9.36

Update to ASHRAE Ventilation Standards. William P. Bahnfleth, PhD, PE, FASHRAE, FASME The Pennsylvania State University University Park, PA, USA

GAS SAFETY Information Bulletin

BC BUILDING CODE ERRATA

City of Peterborough

A, B, C, D VENTILATION SYSTEMS: COMPARISON

INTERIOR ENVIRONMENT

A FIELD STUDY OF AIRFLOW IN MID TO HIGH-RISE MULTI-UNIT RESIDENTIAL BUILDINGS

A Field Study of Airflow in Mid to High-Rise Multi-Unit Residential Buildings

ORDER OF AN EXECUTIVE OFFICER CLOSED FOR TENANT ACCOMMODATION PURPOSES ORDER TO VACATE

LEED for Homes Approved ID Request:

2014 British Columbia Building Code Changes

Chapter 2: Foundation

NEW HOMES PROGRAM 2017 PROGRAM GUIDE

Bulletin BLD May 24, 2013 (Updated September 26, 2017) SECONDARY SUITES

12/20/2010. NIST Capabilities/Program Opportunities for Manufactured Housing what s up in Gaithersburg OUTLINE. NIST IAQ and Ventilation Group

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

SectIon Energy Effldency

IMC 2012 WORKBOOK Equipment and Appliances on Roofs or Elevated Structures

Village of Glen Ellyn Basement Remodeling Project Guidelines

NOTICE OF ADOPTED AMENDMENTS

Energy Efficiency For Housing

Tips. Safety. Installing a Fireplace. Alberta s Safety System. Factory-built fireplaces

Legalization of Dwelling Units Installed Without a Permit SCREENING FORM No fee to file

Building & Ductwork Airtightness Standards

Evaluation Report CCMC R Tyvek HomeWrap - Air Barrier Material

ORDER OF AN EXECUTIVE OFFICER CLOSED FOR TENANT ACCOMMODATION PURPOSES ORDER TO VACATE

RESIDENTIAL REMODELING AND BASEMENT FINISH

2015 NORTHERN NEVADA ENERGY CODE AMENDMENTS Reflecting the changes to the 2012 IECC

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

SPECIFICATIONS PROPOSAL & BID DOCUMENT. Sioux City, Iowa

NAHB s Recommendations on Critical 2015 ICC Code Change Proposals

ORDER OF AN EXECUTIVE OFFICER UNFIT FOR HUMAN HABITATION ORDER TO VACATE

Reducing Air Leakage Through Envelope Retrofits: Does Your Building Suck?

Chapter 8: Indoor Environmental Quality

Section 5.7. Surface Water

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

3.1 Noise Overlay District

Supplementary Standard SB-12. Energy Efficiency For Housing

Passive House Northwest AIA CEU Provider

Basement Renovation Guide For Residential Dwellings

ICC INTERNATIONAL, MECHANICAL CODE 2012 edition

2015 IBC Exit Systems

ORDER OF AN EXECUTIVE OFFICER CLOSED FOR TENANT ACCOMMODATION PURPOSES ORDER TO VACATE

Evaluation Report CCMC R Excel Air Barrier

A STUDY OF CROSS CONTAMINATION OF IN-SUITE VENTILATION SYSTEMS USED IN MULTI-UNIT RESIDENTIAL BUILDINGS

Draft Indoor Air Quality Regulations

ORDER OF AN EXECUTIVE OFFICER UNFIT FOR HUMAN HABITATION

Evaluation Report CCMC R Surround HouseWrap - Air Barrier Material

Attn: Architects, professional engineers, industrial/commercial/institutional contractors and other stakeholders

airflow in to, out of, and within buildings. These airflows are resisted by the airtightness of building elements including the exterior enclosure and

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

RESIDENTIAL BUILDING REQUIREMENTS

ORDER OF AN EXECUTIVE OFFICER CLOSED FOR TENANT ACCOMMODATION PURPOSES ORDER TO VACATE

LEED v4 Building Design and Construction Quiz #8 EQ

Secondary Suite This form is used for both existing and new construction of a secondary suite in an existing structure

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

City of Guntersville Residential Building Permit

BC BUILDING CODE ERRATA

C-TRAC Meeting # 8 Topic: IgCC Chapter 8: Indoor Environmental Quality Wednesday August 18, 2010, 3 5:30 pm

Transcription:

BUILDING CODE BULLETIN September 2010 06-BCB-007 Page 1 of 5 VENTILATION AIR FOR DWELLING UNITS IN MULTI-UNIT RESIDENTIAL BUILDINGS DISCUSSION This STANDATA has been developed to cover alternative methods of supplying ventilation air to dwelling units and suites that are served by corridors in multi-unit residential buildings. Included in this category are multi-unit residential buildings such as condominiums, apartments, hotels or motels. Past practice to provide the ventilation air to suites in a multi-unit residential occupancy is to pressurize the corridor with a supply of outdoor ventilation air and rely on infiltration through the entrance doors of the individual suites or to provide transfer grilles over the entrance doors to facilitate air passage through the fire separation. There has been a significant amount of research that indicates that these systems are not efficient at providing a reasonable level of indoor air quality and the level of ventilation required by the Alberta Building Code, for a number of reasons: 1. Stack and wind effects can cause individual suites to pressurize and prevent corridor air from entering and can adversely affect the operation of conventional corridor air supply and exhaust systems. 2. Occupant-installed door gaskets and weather-stripping can seal the doorway, preventing any corridor air from entering the suite. This would tend to indicate that suite occupants are not satisfied with the air quality and/or noise levels entering their suites from the corridors. 3. Maximum permitted gaps around doors in fire separations being inadequate to permit required air transfer. 4. Corridor air contamination from occupant activities within suites (i.e. cooking and smoking odors) as well as occupant activities in the corridors (i.e. smoking). 5. Suite air contamination from occupant activities in the corridors, such as smoking odors. 6. The ventilation air supplied to the corridor can find alternate paths through vertical shafts, stairwells and improperly sealed building construction joints, decreasing the level of corridor pressurization and thereby reducing the amount of ventilation air to each suite. Unless stated otherwise, all Code references in this STANDATA are to Division B of the Alberta Building Code 2006. Issue of this STANDATA is authorized by the Acting Chief Building Administrator [Original Signed] Chris Salvian, P.Eng. Alberta Municipal Affairs Safety Services, 16th Floor, 10155-102 Street, Edmonton, Alberta, Canada, T5J 4L4 Safety Codes Council, Suite 1000, 10665 Jasper Avenue, Edmonton, Alberta, Canada, T5J 3S9

7. Required sound transmission ratings are negated by the installation of transfer grilles. These grilles also offer a direct path for fire, smoke and odors from the corridor to pass directly into the suites. 8. Exterior contamination via the hallway pressurization system. i.e. carbon monoxide, IAQ, etc. CODE REFERENCES 1. Sentence 5.9.1.2.(1) states: 1) Except as provided in Sentence (2), a dwelling unit shall be separated from every other space in a building in which noise may be generated by construction providing a sound transmission class rating not less than 50, measured in accordance with the standards referenced in Sentence 5.9.1.1.(1). (See A-9.11.1.1.(1) in Appendix A.) 2. Article 6.2.2.1. states: 6.2.2. Ventilation 6.2.2.1. Required Ventilation 1) Except as provided in Sentence (3), all buildings shall be ventilated in accordance with this Part. 2) Except in storage garages covered by Article 6.2.2.3., the rates at which outdoor air is supplied in buildings by ventilation systems shall be not less than the rates required by ANSI/ASHRAE 62, Ventilation for Acceptable Indoor Air Quality. 3) Self-contained mechanical ventilation systems serving only one dwelling unit which conform to the requirements of Subsection 9.32.3. shall be considered to satisfy the requirements of this Article. 3. Article 9.10.13.2. states: 9.10.13.2. Solid Core Wood Door as a Closure 1) A 45 mm thick solid core wood door is permitted to be used where a minimum fireprotection rating of 20 min is permitted or between a public corridor and a suite provided that the door conforms to CAN/ULC-S113, Wood Core Doors Meeting the Performance Required by CAN/ULC-S104 for Twenty Minute Fire Rated Closure Assemblies. (See Appendix A.) 2) Doors described in Sentence (1) shall have not more than a 6 mm clearance beneath and not more than 3 mm at the sides and top. 4. Sentence 9.11.2.1.(1) states: 1) Except as provided in Sentence (2), every dwelling unit shall be separated from every other space in a building in which noise may be generated by a construction providing a sound transmission class rating of at least 50, measured in accordance with Subsection 9.11.1. or as listed in A-9.10.3.1. in Appendix A. Page 2 of 5

5. Article 9.32.1.2. states: 9.32.1.2. Required Ventilation 1) Every residential occupancy shall incorporate a) provisions for non-heating-season ventilation in accordance with Subsection 9.32.2., and b) except as required by Sentence (2), if supplied with electrical power and a heating system, provisions for heating-season ventilation in accordance with Part 6. 2) A self-contained heating-season ventilation system serving a single dwelling unit shall comply with Subsection 9.32.3. 6. Sentences 9.32.3.7.(1) to (4) state: 9.32.3.7. Supplemental Exhaust 1) Except as provided in Sentences (2) and (3), a supplemental exhaust fan with a rated capacity not less than 50 L/s shall be installed in each kitchen. 2) A supplemental exhaust fan is not required in a kitchen where the only exhaust air intake for the principal ventilation fan is located in that kitchen. 3) A supplemental exhaust fan is not required in a kitchen where the principal ventilation fan draws from that kitchen and other rooms, provided a) the principal ventilation fan can be switched to a high exhaust rate equal to not less than 2.5 times the minimum normal operating exhaust capacity specified in Table 9.32.3.3., and b) the high exhaust rate of the principal ventilation fan, as described in Clause (a), is activated by a manual switch in the kitchen labelled KITCHEN EXHAUST. 4) Where an exhaust air intake for the principal ventilation fan is not located in a bathroom or water-closet room, a supplemental exhaust fan with a rated capacity not less than 25 L/s shall be installed in that bathroom or water-closet room. 7. ASHRAE 62-2001 requires the following minimum rates of ventilation for residential occupancies: a. Living areas: 0.35 air changes per hour but not less than 15 cfm (7.5 L/s) per person. b. Kitchens: 100 cfm (50 L/s) intermittent or 25 cfm (10 L/s) continuous or openable windows. (for exhaust only. Climatic conditions may affect choice of the ventilation system) c. Baths, Toilets: 50 cfm (25 L/s) intermittent or 20 cfm (10 L/s) continuous or openable windows. (for exhaust only) DESIGN OPTIONS In light of the above-mentioned factors, it is recommended that alternate methods of suite ventilation be utilized, such as: Page 3 of 5

1. Supply Ducts To Each Suite From Central System Individual suites provided with a ventilation duct branch that passes through the corridor wall to provide central ventilation make-up air to each suite. Designers and installers are cautioned to ensure fire dampers are installed properly at locations where the ducts pass through required fire separations. Corridor air ventilation is provided by the central system at reduced rates. Facilitates operation and maintenance since equipment is centrally located. Clearance required in hallway floor space for large ductwork. Room required on each floor for central ductwork to pass through floors with vertical shafts. Difficult to provide occupants with direct control of ventilation levels. Susceptible to the transfer of suite-to-suite noise through ductwork. Smoke contamination hazard, as fire dampers do not respond to the presence of smoke alone. Extra care must be taken to ensure fire dampers and fire stopping are installed correctly. 2. Supply Ducts to Each Suite from Floor-by-Floor System Individual suites provided with a ventilation duct branch that passes through the corridor wall to provide central ventilation make-up air to each suite. Each floor of the building has a make-up air unit. Designers and installers are cautioned to ensure fire dampers are installed properly at locations where the ducts pass through required fire separations. Corridor air ventilation is provided by the central system at reduced rates. Eliminates the amount of room required for central ductwork to pass through floors with vertical shafts. Page 4 of 5

Not as susceptible to wind and stack effects as central systems. The servicing or failure of one unit does not affect the entire building. Facilitates operation and maintenance since equipment is centrally located. Clearance required in hallway floor space for large ductwork. Susceptible to the transfer of suite-to-suite noise through ductwork. 06-BCB-007 Smoke contamination hazard, as fire dampers do not respond to the presence of smoke alone. Extra care must be taken to ensure fire dampers and fire stopping are installed correctly. 3. Self-Contained Mechanical Ventilation Systems Individual suites provided with self-contained mechanical ventilation systems (i.e. fancoil units, mechanical rooms on balconies, HRV s, etc.). These systems provide ventilation air to individual suites and would then be designed according to Section 9.32. of the Alberta Building Code. Corridor air ventilation is provided by a separate system at reduced rates. Gives occupants direct control of ventilation levels in each suite. Eliminates central ductwork and fire separation penetration problems. More building envelope penetrations may be required. May require more suite space. Potential problems with maintenance (becomes more of an issue for individual tenants). Please note: Other options may be available that provide the same or better level of ventilation that would be acceptable to the authority having jurisdiction. These designs are left to the discretion of the designer and builders, in consultation with the authority having jurisdiction. Designers are cautioned that the authority having jurisdiction may require proof of ventilation rates to individual suites (i.e. calculations, computer simulations, scale models). Page 5 of 5