Color, True and Apparent, LR

Similar documents
Scope and application: For water and wastewater. Turbid samples are filtered during the analysis.

Scope and application: For water, wastewater, seawater, brine solutions, produced waters and hydraulic fracturing waters.

Phosphorus, Reactive (Orthophosphate)

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows

1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method to mg/l Mn (LR) Powder Pillows

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting.

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

Hardness, Calcium/Magnesium

Oxygen Demand, Chemical

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Nitrogen, Simplified TKN (s-tkn )

Dimethylphenol Method Method LR (0.23 to mg/l NO 3 N or 1.00 to mg/l NO 3 ) TNTplus 835

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Phosphorus, Reactive (Orthophosphate)

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Phosphorus, Reactive (Orthophosphate)

Instrument Adapters Light shield DR 6000, DR 5000 DR 3900 LZV849 DR 3800, DR 2800 LZV646 DR or (A)

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium.

DR/4000 PROCEDURE. IRON, Ferrous. Using Powder Pillows

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

Table 163 Instrument-specific information. Instrument Pour-thru Kit Cell orientation Adapter. DR 6000 LQV Arrow faces right

Oxygen Demand, Chemical

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

Sulfate DOC SulfaVer 4 Method 1. Method (0 70, and mg/l) Powder Pillows. Test procedure

Method to 500 µg/l CH 2 O Powder Pillows

Oxygen Demand, Chemical

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

Nitrogen, Simplified TKN (s-tkn ) DOC

Oxygen Demand, Chemical

PHOSPHORUS, REACTIVE (0.00 to 5.00 mg/l PO 4

Direct ISE Method Method to 10.0 mg/l F Fluoride ISE

Direct ISE Method Method to 4.00 mg/l NO 3 N Nitrate ISE

USEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.

Heterotrophic Bacteria

TPTZ Method * (Powder Pillows or AccuVac Ampuls) Using Powder Pillows

STP (off-line) Water Technologies & Solutions analytical procedure. colorimetric method DCA reagent 1 (5/5/1) 2 to 15 mg/l as STP

FerroVer Method (Powder Pillows or AccuVac Ampuls) USEPA approved for reporting wastewater analysis (digestion is required; see Section 2 * )

PaSEC Colorimeter Instructions DR850

3. Add 0.4 ml of. 7. Use a TenSette

1,5-Diphenylcarbohydrazide Method* (Powder Pillows or AccuVac Ampuls) USEPA accepted for wastewater analyses** Using Powder Pillows

3. Add 0.4 ml of. 7. Use a TenSette

Coliforms, Total and E. coli

DR/4000 PROCEDURE OXYGEN SCAVENGERS. 4. Fill a second sample cell (the blank) with 25 ml of deionized water.

3. Fill a 50-mL. 2. Press: 1 ENTER The display will show mg/l, Al and the ZERO icon.

3. Fill a 50-mL. 2. Press: 1 ENTER The display will show mg/l, Al and the ZERO icon.

1,10 Phenanthroline Method * (Powder Pillows or AccuVac Ampuls) Using Powder Pillows

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Oxygen Demand, Biochemical

Amperometric Titrator assembly. Digital Titrator. Beaker, low-form, 250-mL. Stir bar, octagonal, Teflon-coated, 50.8 x 7.9 mm

Engineered Systems & Designs TURBIDITY METER

Rev Experiment 10

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1122 DETERMINING SULFATE CONTENT IN SOILS. July 17, 2015

SUMMARY OF STANDARDS FOR WATER ANALYSIS ON COURSE WAT-E2120 SPRING 2017

Methods and Materials Manual Of Ion Chromatography Using DX-100 IC. Collecting Samples. LDPE bottle with cap (pre-rinsed with DI water)

OPERATING INSTRUCTIONS. Portable Turbidity Meter

BONDERITE NT-1 Phosphate-free, Regulated Heavy Metal-Free Pre-treatment

CEE 311 Environmental Engineering I Fall 2015 Dr. Jagadish Torlapati BIOCHEMICAL OXYGEN DEMAND (BOD)

SurTec 650 chromital TCP

NACA Laboratory Equipment and Supplies

Protocol. Envirochek HV Sampling Capsule. 1.0 Sample Collection Materials

Human CRP Precoated ELISA kit

Method 5.2 Syrup and remelt: Brix, NIR pol and purity

Technical Process Bulletin

Professional Boiler Water Test Kit

Turbidity by Nephelometric Determination

The determination of copper in brass

SOP-C-107 Determination of Non Filterable Residue

30th International Chemistry Olympiad

PLANS for the Chesapeake Bay A Teacher s Guide

SPECTROPHOTOMETRIC DETERMINATION OF IRON

TC-3000e Code 1964-EPA TC-3000i Code 1964-ISO

Sampling Day Activities

Free, Total and Double SO2 in Wine

Experiment 3: Determination of an Empirical Formula

Hach Method Determination of Turbidty by Laser Nephelometry*

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

Ti-Pure TITANIUM DIOXIDE. CONCENTRATED ACID SOLUBILITY OF TiO 2 METHOD: T WP

Collecting a Surface Water Sample

VISCOSITY, INHERENT (One Point)

Total Residual Chlorine Testing Methods

5 - Chlorophyll Analysis Lab.

Biochemical Oxygen Demand

Total Dissolved Solids Dried at 180ºC. Total Volatile Dissolved Solids at 550 C

SOP-C-109 Determination of Filterable Residue

COPPER CYCLE EXPERIMENT 3

F U C H S L U B R I C A N T S C O.

Method 6.1 Boiling house products: Brix, pol and purity

MyBioSource.com. Human Vitamin K2 ELISA USER INSTRUCTION

:00 am 6:00 pm Mon-Thu (MT) 6:00 am 5:00 pm Fri (MT)

Method 4.2 Filter cake, filter feed and filtrate: Brix, NIR pol and purity

3.0 DETECTION LIMIT 3.1. See Procedure ALQAP Procedure for the Determination of Uncertainty

MyBioSource.com. Human Osteoprotegerin ELISA USER INSTRUCTION

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum

EPK- EasyTest Patch Test Kit Manual

Technical Process Bulletin

Human High sensitivity C Reactive Protein ELISA KIT

Name Honors Chemistry / /

MyBioSource.com. Rat Hydroxyproline ELISA USER INSTRUCTION

Transcription:

Color, True and Apparent, LR DOC316.53.01252 Platinum-Cobalt Standard Method 1, 2, 3 Method 8025 3 to 200 color units Scope and application: For water, wastewater and seawater; equivalent to NCASI method 253 and NCASI Method Color 71.01 for pulp and paper effluent using 465 nm (ph adjustment necessary). 1 Adapted from Standard Methods for the Examination of Water and Wastewater and National Council for Air and Stream Improvement (NCASI) Methods Manual. 2 Adapted from Wat. Res. Vol. 30, No. 11, pp. 2771 2775, 1996. 3 NCASI Method 253 approved at 40 CFR part 136. Test preparation Instrument-specific information Table 1 shows all of the instruments that have the program for this test. The table also shows sample cell and adapter requirements for this test. To use the table, select an instrument, then read across to find the applicable information for this test. Table 1 Instrument-specific information Instrument Adapter Sample cell DR 3900, DR 3800, DR 2800, DR 2700 2629250 DR 5000 A23618 DR 6000 LZV902.99.00020 Before starting The NCASI procedure is available only for spectrophotometers and ph adjustment to ph 7.6 with 1.0 N HCl or 1.0 N NaOH is a requirement. If the volume change during the adjustment is more than 1%, start again and use a stronger acid or base. Use Program 124 for the NCASI procedure. To minimize the volume change from the dilution, add one ph 8 buffer powder pillow (sodium phosphate/potassium phosphate) to 50 ml of sample before the final ph adjustment. Fully mix to dissolve before the final ph adjustment. To test for apparent color, do not filter the sample or the deionized water blank. Refer to Method technique on page 4 for precautions on low-level color measurements. Review the Safety Data Sheets (MSDS/SDS) for the chemicals that are used. Use the recommended personal protective equipment. Dispose of reacted solutions according to local, state and federal regulations. Refer to the Safety Data Sheets for disposal information for unused reagents. Refer to the environmental, health and safety staff for your facility and/or local regulatory agencies for further disposal information. Items to collect Description Quantity Buffer, ph 8.0 (Program 124) 1 Hydrochloric Acid Solution, 1.0 N (Program 124) varies Sodium Hydroxide, 1.00 N (Program 124) varies Water, deionized 100 ml Filter apparatus: membrane filter, filter holder, filter flask and aspirator 1 1

Items to collect (continued) Description Quantity Stopper, rubber, one hole, number 7 1 Tubing, rubber 1 Sample cells (For information about sample cells, adapters or light shields, refer to Instrumentspecific information on page 1.) 2 Refer to Consumables and replacement items on page 6 for order information. Sample collection and storage Platinum-Cobalt Standard Procedure Collect samples in clean glass or plastic bottles. Analyze the samples as soon as possible for best results. If prompt analysis is not possible, fill the bottle completely full, then tighten the cap on the bottle. Avoid excessive agitation or prolonged contact with air. To preserve samples for later analysis, keep the samples at or below 6 C (43 F) for up to 48 hours. Let the sample temperature increase to room temperature before analysis. Start 1. Start program 121 LR Color, 455 nm. For the NCASI test, program 124 LR Color, 465 nm. For information about sample cells, adapters or light shields, refer to Instrumentspecific information on page 1. 2. Collect 200 ml of sample in a 400 ml beaker. NCASI: Adjust the ph as described in Before starting on page 1. 3. Assemble the 0.45 micron filter apparatus. NCASI: Use a 0.8 micron filter for the NCASI test. For samples that are difficult to filter, use a 1.0 micron prefilter first. 4. Pour approximately 50 ml of deionized water through the filter. Discard the filtered water. Note: Although the program name can be different between instruments, the program number does not change. 2 Color, True and Apparent, Platinum-Cobalt Method (200 units)

5. Pour another 50 ml of deionized water through the filter. 6. Prepare the blank: Fill the sample cell with 10 ml of filtered deionized water from the previous step. Discard the remaining water in the flask. 7. Clean the blank sample cell. 8. Insert the blank into the cell holder. DR 2700, DR 2800, DR 3800 and DR 3900: Slide the sample cell to the right side of the cell compartment to consistently align the cell. Close the lid. Zero 9. Push ZERO. The display shows 0 units PtCo 50 mm. 10. Pour approximately 50 ml of sample through the filter. 11. Prepare the sample: Fill a second sample cell with 10 ml of filtered sample. 12. Clean the prepared sample cell. Read 13. Insert the prepared sample cell into the cell holder. DR 2700, DR 2800, DR 3800 and DR 3900: Slide the sample cell to the right side of the cell compartment to consistently align the cell. Close the lid. 14. Push READ. Results show in units PtCo 50 mm. Accuracy check Standard solution method Use the standard solution method to validate the test procedure, the reagents and the instrument. Color, True and Apparent, Platinum-Cobalt Method (200 units) 3

Items to collect: Standard solution within the test range 1. Use the test procedure to measure the concentration of the standard solution. 2. Compare the expected result to the actual result. Note: The factory calibration can be adjusted slightly with the standard adjust option so that the instrument shows the expected value of the standard solution. The adjusted calibration is then used for all test results. This adjustment can increase the test accuracy when there are slight variations in the reagents or instruments. Method performance The method performance data that follows was derived from laboratory tests that were measured on a spectrophotometer during ideal test conditions. Users can get different results under different test conditions. Program Standard Precision (95% Confidence Interval) Sensitivity Concentration change per 0.010 Abs change 121 (455 nm) 15 units Pt-Co 14 to 16 units Pt-Co 7.4 units Pt-Co 124 (465 nm) 15 units Pt-Co 14 to 16 units Pt-Co 7.6 units Pt-Co Method technique Zero and read the sample Use good laboratory technique and give attention to detail for accurate, reproducible results on waters that have true color values less than 15 Pt-Co color units. 1. Clean the sample cell with soap and water or with an acid-rinse to remove contaminants (e.g., dirt, grease, finger prints and so on). 2. Rinse the sample cell several times with filtered deionized water. 3. Fill the cleaned sample cell with 6 ml of deionized water. 4. Use a lint-free towel to clean the sample cell windows. 5. Make sure that there are no trapped air bubbles and no lint or smudges on or in the sample cell. 6. Carefully tap the sample cell to remove trapped air bubbles. 7. Insert the sample cell into the cell holder. Then push Zero. Note: The sample cell may initially fit tightly in the sample cell holder, but will loosen slightly with additional use. There may be some small variations between cell manufacturers. 8. Remove the sample cell and do steps 1 and 2 again to clean the cell. 9. Fill the cleaned sample cell with deionized water. Do steps 4 to 6again. 10. Put the sample cell in the holder, then push Read. If the instrument does not show "0", the sample cell was not correctly cleaned. Make sure that there are no trapped bubbles in the sample cell and the sample cell is correctly aligned. Filter the sample cell It is not known if apparent color values are meaningful in low level color measurements. Turbidity or suspended particles can contribute to the measured color value and can cause high results. It is recommended that all samples for low level color measurements are first filtered through a membrane filter and the results are reported as true color. 1. Set the instrument to Zero. 2. Discard the deionized water and rinse the sample cell at least two times with the filtered sample. 3. Fill the sample cell with filtered sample. Make sure that there are no bubbles or smudges on the sample cell. 4. Put the cell into the cell holder to do a measurement. 4 Color, True and Apparent, Platinum-Cobalt Method (200 units)

Clean the sample cell After the measurements are completed, fully rinse the sample cell with deionized water, then dry the sample cell. Put the sample cell in an environment with no dust. Make sure that this environment is only for LR color measurements. For more sample measurements do the cleaning procedure again. Summary of method Color may be expressed as apparent or true color. Apparent color includes color from dissolved materials and color from suspended matter. True color is determined by removal of the suspended materials with a filter or a centrifuge. This method uses 0.45- micron filtration for true color analysis. To measure apparent color, do not filter the sample or the deionized water blank. The same instrument program is used for both true and apparent color. The stored program is calibrated in color units based on the APHArecommended standard of 1 color unit being equal to 1 mg/l platinum as chloroplatinate ion. Test results for Programs 121 and 124 are measured at 455 and 465 nm, respectively in spectrophotometers. Test results for Program 122 are measured at 420 nm in colorimeters. Set up the instrument The steps that follow are general instructions for all instruments. Refer to the instrument documentation that is used for the correct menu options. For instruments that do not have programs 121 and 124, make a new user program as follows. 1. Set the instrument power to on, then let the instrument complete the self-check. 2. Obey the prompts on the display to enter commands for the 455 nm or 465 nm methods. 3. Go to User Programs. 4. Select a new user program and enter the settings for each option: Option Program Number (950 999)? Program Name? Program Type Units Wavelength (nm) Description Select a Program Number Enter the program name: LR_Color_455_nm or LR_Color_465_nm Select Single Wavelength Enter the applicable units Select 455 or 465 nm Concentration resolution Select the concentration resolution: 1 Chemical form? Calibration Enter formula User Progam for number assigned Upper limit Select the chemical form: PtCo_50_mm Enter Formula 455 nm: b=737.70 465 nm: b=764.00 Upper Limit ON>220 User Program for number assigned Lower Limit Lower limit ON>3 5. Make the necessary selection to save, edit or exit an option. Color, True and Apparent, Platinum-Cobalt Method (200 units) 5

Consumables and replacement items Required reagents Description Quantity/test Unit Item no. Water, deionized varies 4 L 27256 Required reagents (Program 124): Buffer, ph 8.0 1 15/pkg 1407995 Hydrochloric Acid Solution, 1.0 N varies 1 L 2321353 Sodium Hydroxide, 1.0 N varies 1 L 104553 Required apparatus Description Quantity/test Unit Item no. Aspirator, vacuum pump 1 each 213100 Beaker, 400-mL 1 each 50048 Filter holder, 47-mm, magnetic base 1 each 1352900 Filter, membrane, 47-mm, 0.8-microns, Program 124 1 100/pkg 2640800 Filter, membrane, 47-mm, 0.45-microns 1 100/pkg 1353000 Flask, filtering, 500-mL 1 each 54649 Sample cell, rectangular glass, 5-cm 1 each 2629250 Stopper, poly, hollow 1 6/pkg 211907 Tubing, rubber, 7.9 mm x 2.4 mm varies 12 ft 56019 Optional reagents and apparatus Description Unit Item no. Color Standard Solution, 500 platinum-cobalt units 1 L 141453 Color Standard Solution, 15 platinum-cobalt units 1 L 2602853 Filter, glass microfiber, 1.0-micron 47-mm 100/pkg 2551400 Flask, volumetric, Class A, 500-mL glass each 1457449 Hydrochloric Acid Solution, 6.0 N (1:1) 500 ml 88449 Liqui-Nox Phosphate-free detergent 946 ml 2088153 Pipet, volumetric, Class A, 50-mL each 1451541 Pipet filler, safety bulb each 1465100 Sample cell, 5-cm rectangular quartz each 2624450 Wipes, disposable 280/pkg 2097000 FOR TECHNICAL ASSISTANCE, PRICE INFORMATION AND ORDERING: In the U.S.A. Call toll-free 800-227-4224 Outside the U.S.A. Contact the HACH office or distributor serving you. On the Worldwide Web www.hach.com; E-mail techhelp@hach.com HACH COMPANY WORLD HEADQUARTERS Telephone: (970) 669-3050 FAX: (970) 669-2932 Hach Company/Hach Lange GmbH, 2008 2014. All rights reserved. 11/2014, Edition 4