INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

Similar documents
4-Wire Buffer Amplifier. User Manual

Effective This guide supersedes all previous versions

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: SWM-1 Loudspeaker Wall Mount Device. P/N: Rev 1

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

OPTO BRANCH 8. ELATION OPTO BRANCH 8 user manual 1.0

RUBBER BANDS 500 USER'S MANUAL. IGS Audio Igor Sobczyk 3 Maja 76d, Mysłowice, Poland ph:

Installation. Basic Rack Power Distribution Units AP9560 AP9561

CMR Quick Start Guide. CMR-5975 Digicast Media Router (MR-S2) Part Number MN-CMR5975-QSG REV. 3

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

Dynatronics Parallel Bars

USER MANUAL. Model TIF 2000 Digital Hybrid Telephone Line Interface

MANUAL ENGLISH. Ordercode: D3423/D3423W. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Continuous Wave Single Frequency Lasers. SYMPHONY Series. 532nm 2000mW

CM-95 ORDERCODE D1355 Highlite International B.V.

Mechanical Medic-Aid 6 Selection Vending Machine Operator s Manual

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

TEACO TRUCK DOCK PARK ASSISTANT. MODEL DockView -16 FORWARD/REVERSE READING DISTANCE INDICATOR

SAVE THESE INSTRUCTIONS

DUST FREE ACTIVE Total Home Air Purification

HDI 2200 Choke Position Indicator

OptoLum MegaLine RGBW Luminaire

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

USER'S GUIDE TO OPERATION

INSTALLATION PROCEDURE

EP100 EMERGENCY POWER BANK

Instruction Manual V2.0. Instruction Manual. Laser Diode Drivers Models: LSP-500/1000/1500/-XK-XX

Continuous Wave Single Frequency Lasers. SCHERZO Series. 532nm 300mW

Instruction Manual V2.0. Instruction Manual. High Power Laser Diode Drivers/High Voltage Pulser/ High Voltage Switch Models: LSP-500/1000/1500/-XK-XX

ENMET Corporation PO Box 979 Ann Arbor, MI GS-24-DF. Manual October 2003 MCN-314, 12/05/03

Vinyl Fence Gates. Assembly and Installation Instructions PLEASE READ OWNER'S MANUAL COMPLETELY BEFORE ASSEMBLING YOUR FENCE.

Signal Follower Card. Instruction Manual Model C

Func HS-260 Gaming Headset

Infant Warmer Care Station Cabinet Light

Mechanical Post Lift. Owner s Manual

Limited Product Warranty

NILES. BLENDING HIGH FiDELITY AND ARCHITECTURE

Wash Down Duty Non-Contact Sensor

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

N-SERIES SUBWOOFERS USER MANUAL

New Advanced Environmental Air Treatment System

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Thermoelectric Cooler

Installation Manual. LIFETIME LIMITED WARRANTY Warranty applies to select Residential faucets only. Pressure Balance Valve TSPVR & TSPTR

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

Instructions and E00 Series Sampling Module Extenders

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

UNI BAR. user manual. ELATION UNI BAR user manual

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

CHANDLER LIMITED TG12345 MKIV USER MANUAL

DJ Switch 10F V2 ORDERCODE 50365

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

TL-600 MOBILE PHASE HEATER

Model HH Signal-Conditioner / Indicator

User s Guide RC-3 REMOTE VOLUME CONTROL.

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

Qualstar Technical Support

1501 Incubator for Ampoule Biological Indicators

DGF-P 2001 CONVEYORS

WALL SHELVES. Cleaning and Maintenance INSTRUCTION MANUAL

FCT FCT [UB] [UB] FCT [UB] Signal Converter/Isolator. Signal Converter/Isolator. Page 1. April B. The Interface Solution Experts

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

92831 TEL: (714) FAX:

General Safety Information

Elevation Station MODEL: ES.02-16

DICKSON TH8 DICKSON. Temperature & Humidity Chart Recorder Operation. Useful Features. Applications & Product. Specifications. Product.

STAINLESS STEEL PEG BOARDS

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

Field Economy Unit Instruction Manual

Global Water Instrumentation, Inc.

NetShelter. Four-Post Rack. Installation and Quick-Start Manual

AQUA UNO TUB DOOR INSTALLATION INSTRUCTIONS

New Advanced Environmental Air Treatment System

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

General-Purpose Scale Bases

E3X-DRT21/SRT21/CIF11

PASSIVE IN-WALL SUBWOOFER & MOUNTING BRACKET

Smart-UPS X-Series External Battery Pack Installation and Operation

INSTALLATION INSTRUCTIONS

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

DSF290 TRUSS MOUNT FOR 12 TRUSS WITH 2 OUTER DIAMETER TUBING

CA11 11 Column. Operator s Manual. To Purchase This Item, Visit BMI Gaming LIMITED WARRANTY

Sby SR Instruments, Inc.

GC-X360S-W GC-X360S-B

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Pallet Jack 4,400 Lbs Capacity Model #31001

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

WARRANTY GENERAL POLICY AND RETURN GOODS PROCEDURE. For Original Equipment Manufacturers Only

P R I C E L I S T 1

DMC When Accuracy Counts

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

Transcription:

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM 9350-7686-000 Rev. H 08/2004

TRADEMARKS AudioCom is a registered trademark of Telex Communications. Names of other products mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies. WARRANTY INFORMATION Products are warranted by Telex Communications, Inc. to be free from defects in materials and workmanship for a period of one year from the date of sale. The sole obligation of Telex during the warranty period is to provide, without charge, parts and labor necessary to remedy covered defects appearing in products returned prepaid to Telex. This warranty does not cover any defect, malfunction or failure caused beyond the control of Telex, including unreasonable or negligent operation, abuse, accident, failure to follow instructions in the manual, defective or improper associated equipment, attempts at modification and repair not authorized by Telex, and shipping damage. Products with their serial numbers removed or effaced are not covered by this warranty. To obtain warranty service, follow the procedures entitled Procedure for Returns and Shipping to Manufacturer for Repair or Adjustment. This warranty is the sole and exclusive express warranty given with respect to Audiocom products. It is the responsibility of the user to determine before purchase that this product is suitable for the user s intended purpose. ANY AND ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY ARE LIMITED TO THE DURATION OF THIS EXPRESS LIMITED WARRANTY. NEITHER TELEX NOR THE DEALER WHO SELLS TELEX PRODUCTS IS LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND. CUSTOMER SUPPORT Technical questions should be directed to: Customer Service Department Telex 12000 Portland Avenue South Burnsville, MN 55337 U.S.A Telephone: (952) 884-4051 Fax: (952) 884-0043 RETURN SHIPPING INSTRUCTIONS Procedure for Returns If a return is necessary, contact the dealer where this unit was purchased. If a return through the dealer is not possible, obtain a RETURN AUTHORIZATION from: Customer Service Department Telex Communications, Inc. Telephone: 1-800-392-3497 or (952) 884-4051 Fax: 1-800-323-0498 or (952) 884-0043 DO NOT RETURN ANY EQUIPMENT DIRECTLY TO THE FACTORY WITHOUT FIRST OBTAINING A RETURN AUTHORIZA- TION. Be prepared to provide the company name, address, phone number, a person to contact regarding the return, purchase order number, the type and quantity of equipment, a description of the problem and the serial number(s). Shipping to Manufacturer for Repair or Adjustment All shipments of products should be made via United Parcel Service or the best available shipper prepaid. The equipment should be shipped in the original packing carton; if that is not available, use any suitable container that is rigid and of adequate size. If a substitute container is used, the equipment should be wrapped in paper and surrounded with at least four inches of excelsior or similar shock-absorbing material. All returns must include the return authorization number. Units sent for repair or adjustment DO NOT need a return authorization number Factory Service department Telex Communications, Inc. West 1 st Street Blue Earth, MN 56013 U.S.A. Upon completion of any repair the equipment will be returned via United Parcel Service or specified shipper collect.

UNPACKING & INSPECTION 2 5 3 4 ICW-3 Package 1. IEC cord. 2. Switching power supply. 3. ICW-3 to power supply cord. 4. #6 screws 1 (3). 5. Adjustment screwdriver. 6. Customer assembly. 7. Operator assembly. 6 7 1 Figure 1 - ICW-3 system components. Unpack the equipment from the shipping case and inspect for missing or damaged components. You should have all of the items listed next to Figure 1. RECOMMENDED ITEMS 1. No. 1 Phillips screwdriver 2. Equipment for cutting/drilling hole(s) for mounting. (See Installation section for details.) 3. 1 wide transparent tape. 4. Scissors (For cutting the mounting template from the last page.) SPECIFICATIONS Overall Power Requirement: 12 to 15 VDC, 150 ma nominal System Frequency Response: 200 to 4.5 khz ±3 db Environmental: -20 to 55 C, 0 to 90% Humidity, non-condensing Outputs External Speaker: Internal Speaker: Inputs Headphone: Internal Panel Microphone: Internal Headset Microphone: Options Gooseneck Micropone: Headsets: 2 W: 100 db SPL @ 1 foot @ 1 khz, C weighting 2 W: 100 db SPL @ 1 foot @ 1 khz, C weighting Note: These are sine wave maximums. Voice measurements will range 70 to 90 db SPL. 80 mw: 100 db peak SPL Voice Range: 84 to 104 db SPL Impedance: 25 ohms Electret: 15 mv @ 1 khz, typical into 1000 ohms source impednace Dynamic: range 2 mv @ 1 khz, typical into 200 ohms Source Impedance Dynamic: 200 ohms MCP-90-3, MCP-90-8, MCP-90-12, MCP-90-18 PH-44-IC3 (Dual Headphone), PH-88-IC3 (Single Headphone)

INSTALLATION 1. Remove the two screws (one on each side) holding the mounting plate to the operator assembly. (See Figure 3) 2. Measure and identify the location where the intercom is to be mounted. 3. Attach the mounting template to the window (customer assembly side) being sure to center the appropriate guide in the location identified in step 2. Note: There are two guides provided on the last page of these instructions. Use either the single large hole, or multiple small holes depending on which method you choose. Using the multiple small hole method with bullet-proof glass will afford maximum operator protection. (See Figure 4) 4. Cut and/or drill the hole(s) from the customer assembly side. Figure 2 - ICW-3 Assembly detail. 5. Have an assistant place the customer assembly against the window. Make sure the holes line up correctly. Attach the mounting plate removed from the operator assembly (see step 1) using the three supplied mounting screws. (See Figure 5) 6. Attach the cable harness from the customer assembly to the connector on the operator assembly. (See Figure 6) 7. Attach the operator assembly to the mounting plate using the screws removed in step 1. 8. Plug the RJ-45 end of the ICW-3 power supply interface cord into the ICW-3. The connector is located on the bottom of the ICW-3 on the operator assembly side. Secure the cord to the glass using wide clear adheasive tape. 9. Connect the power supply to AC power using the supplied IEC cord. Attach the ICW-3 s power cord to the power supply.

Figure 3 - Customer and operator assemblies. Figure 4 - Mounting template. Figure 5 - Customer side mounted. VOX CIRCUIT ADJUSTMENT Figure 6 - Connecting customer and operator assemblies prior to final mounting. Note: The unit is shipped from the factory with the VOX circuit pre-adjusted. Use this procedure only if you encounter a problem where the VOX circuit does not properly switch between the operator and customer when they are talking. In some situations, particularly when ambient noise levels vary over time, it may be necessary to touch up the VOX adjustments. 1. Locate the two VOX pots: VOX1 and VOX2. They are located on the operator assembly side of the unit. 2. Set VOX1 (top hole) all the way clockwise. Set VOX2 (bottom hole) all the way clockwise. 3. Locate the customer and operator volume controls. They are located on the operator side of the unit. Set each of them to the middle of their adjustment range. 4. Have an assistant talk on the outside microphone and using the included screwdriver adjust VOX1 (top hole) so that the VOX just triggers and you can hear the customer microphone on the headphones or speaker on the operator side. Then turn the pot just a little further. 5. Talk on the gooseneck microphone or headset microphone on the operator side and using the included screw driver adjust VOX2 (bottom hole) so that the VOX just triggers and you can be heard by your assistnat on the speaker on the customer side. Then turn the pot just a little further 6. Talk back and forth and adjust VOX1 (top hole) and VOX2 (bottom hole) very carefully to get the proper VOX switching action. Be sure to talk directly into the microphones because they are close talking.

OPERATION Operator Side Connection for gooseneck microphone Loudspeaker is interrupted when headphones are in use Controls volume of the loudspeaker on the operator side. Rotate knob clockwise to increase volume When the MUTE button is pushed in, the customer cannot hear what the operator is saying Microphone connector Headphone connector VOX1 (outside) Circuit Adjustment (customer side) VOX2 (inside) Circuit Adjustment (operator side) Controls volume of the loudspeaker on the customer side. Rotate knob clockwise to increase volume Loudspeaker Microphone Customer Side

CUT HERE