Turbidity Meter Instruction Manual

Similar documents
Waterproof Digital Refractometer , , , , , & Instruction Manual

Instruction Manual HI Portable Microprocessor Turbidity Meter

OPERATING INSTRUCTIONS. Portable Turbidity Meter

Manual No Revision MODEL GLI HAND-HELD/PORTABLE TOTAL/FREE CHLORINE METER

TB100 Portable Turbidity Meter Instruction Manual

Owner s Manual & Safety Instructions

LP 2000 Microprocessor-based Bench Turbidity Meter

INSTRUCTION MANUAL DAFM3

OWNERS MANUAL. Micro TPI Field Portable Turbidimeter

HI Portable Logging Turbidity Meter with RS232. Instruction Manual MAN R1 08/05 HI LOG LOBAT DATE TIME CLR VIEW ON OFF STO

Instruction Manual. ph20 ph21. Basic ph meters

TN100 PortableTurbidity Meter. Instruction Manual.

Tracer TM Total Chlorine PockeTester Code 1740

WARNING! Read all of the information in this booklet, and any relevant Application Notes, before using the Eco Sensors DO3.

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at

FIELD PROCEDURE: TURBIDITY

PURE WATER METER Model : PWA-301

User's Guide. ExStik CL200A. Waterproof Total Residual Chlorine Tester Patent Pending

Instruction Manual HI Portable ph/ec/tds/ C Meters

Model M120 Mini Temperature/Humidity Meter

Model M130 Mini Anemometer

Environmental Equipment, Inc.

8000 / 8100 ph Meters

SAWDUST MOISTURE METER WTR-1E USERS MANUAL

Typical Experiments. How it Works

HI Seawater Refractometer INSTRUCTION MANUAL

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

Self-cleaning Turbidity Sensor

MAINTENANCE & CALIBRATION: HF TURBIDIMETERS Rev. 4/5/16

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

Model DDS-11C Conductivity Meter Operation Manual Shanghai San-Xin Instrumentation,Inc.

DC-688. When Accuracy Counts

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters

Engineered Systems & Designs TURBIDITY METER

DS-520 Digital Indicator Operation Manual 73366

Model E100 Gauss Meter

Opti-Check Handheld Fluorometer

WeighSouth. WBT Toploader Balance

Hydrogen rich water bottle instruction manual. Model: PEM+

Coating Thickness Gauge Model: AX-CTG10 User s Manual

PHS-3D-01 Lab ph Meter. User s Guide. Shanghai San-Xin Instrumentation, Inc.

MICRO 950 TURBIDITY METER

PROFESSIONAL PHOTO LAMINATOR OWNER'S MANUAL / PLEASE READ AND SAVE INSTRUCTIONS ROYAL SOVEREIGN INTL.INC.

Collecting a Surface Water Sample

Collecting a Surface Water Sample

Instruction Manual HI 9124 HI Portable Waterproof ph Meters

VAN LONDON COMPANY COMBINATION ph ELECTRODE INSTRUCTION MANUAL

P300 ph/mv/t Meter. Manual

MICROPROCESSOR BASED TURBIDITY METER

Dissolved Oxygen Probe (Order Code: DO-BTA)

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Oyster ph - Conductivity - TDS - Temperature Meters

Hydrogen rich water bottle instruction manual

Sby SR Instruments, Inc.

Owner s Manual & Safety Instructions

DRONIUM ZERO DRONE WITH LIVE STREAMING CAMERA

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

EPA Compliant Turbidity & Chlorine Meter

Instruction Manual HI 9124 HI 9125 Portable Waterproof ph Meters

Sample Food Safety Plan MEETS BC REGULATORY REQUIREMENTS RED WINE

DATA LOGGER Model DL-SA11

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

Instruction Manual TN-100/T-100 Portable Turbidimeter

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Operating manual Digital refractometer

Instruction Manual HI RH/ C Transmitter. This Instrument is in Compliance with the CE Directives.

WS 10 Weighing indicator USER MANUAL

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

Ultrasonic Thickness Meter Instruction Manual ET2044. Table of contents. B.B.B.B 11\fs mm

B.David Company World Health Through Water Purification Systems

Model 435A ph Monitor/Recorder Manual

Quick Start TIME mode Set Time... 4 Set Alarm... 5

PTSV403. Camera Parking Assist System. Camera PTSV

Model MP511 Lab ph Meter. Operation Manual. Shanghai San-Xin Instrumentation, Inc.

HY-ALERTA 500 Handheld Hydrogen Leak Detector

ecosphere water purifier 3in1 USER MANUAL

Portable Water Filter Pitcher NFP-100

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

OWNERS MANUAL FOR WATER FILTER JUG

Refractometer Calibration, Use and Maintenance Stephen Vasquez and Shannon Mueller

PD662 LOOP-POWERED METER

WALL SHELVES. Cleaning and Maintenance INSTRUCTION MANUAL

With Discovery Incubator.

Instruction Manual C20

HOBO MX ph and Temperature Logger (MX2501) Manual

Cole Parmer Conductivity Meter

Model 292A. Surface Resistance Test Kit. Instruction Manual

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

INSTALLATION GUIDE MODELS DMV2402 / DMV3002 / DMV3602

Global Water globalw.com. Global Water. Instrumentation, Inc.

SYSTEM 600 GENERAL MAINTENANCE AND ADJUSTMENT GUIDE

FRIDGE OWNER S MANUAL

WHOLE HOUSE FILTER &

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

Quick Start TIME mode Set Time... 4 Set Alarm... 5

Rocking Chair - Natural / White

HOBO MX ph and Temperature Logger (MX2501) Manual

Transcription:

Turbidity Meter 860040 Instruction Manual

TABLE OF CONTENTS INTRODUCTION...2 FEATURES...3 MATERIALS SUPPLIED...3 FRONT PANEL DESCRIPTION...4 SET UP...5 CALIBRATION...6 MEASUREMENT PROCEDURES...8 ZERO ADJUSTMENT...9 CARE AND MAINTENANCE...11 SPECIFICATIONS...11 WARRANTY...12 INTRODUCTION This Sper Scientific Turbidity Meter (model 860040) displays the turbidity level of aqueous solutions on a large LCD screen. This meter can measure numerous different types of aqueous solutions and offers a two-point self-calibration feature that can be performed in under a minute. The meter conveniently displays turbidity in the internationally recognized Nephelometric Turbidity Unit of measure (NTU), used in many industries including the beer/wine, water quality, biological growth, and chemical manufacturing industries. 2

FEATURES Reads turbidity values of aqueous solutions Protective chamber with lid to prevent debris from entering Maximum and Minimum values Portable design for use in the field or laboratory Data Hold Function Optional DC adapter for field use Zero adjustment feature for low turbidity solutions MATERIALS SUPPLIED Turbidity meter Calibration standards solutions of 0 NTU and 100 NTU 2 sampling bottles Instruction manual 6 AAA batteries Carrying case with custom foam interior Low Lint Cloth Distilled Water for cleaning 3

FRONT PANEL DESCRIPTION 1 2 3 4 5 6 7 8 1. Chamber Lid/protective cover 2. Testing chamber 3. LCD screen 4. Data Hold Button 5. Test / Calibration Button 6. Power Button 7. Zero Button 8. Min/Max Button 4

SET UP Battery Installation This meter uses six AAA batteries. To install the batteries before first use: 1. Unscrew the two screws on the back of the meter. These screws secure the battery cover. 2. Remove the battery cover. 3. Insert six new AAA batteries, ensuring correct polarity. 4. Replace the battery cover and reinstall the screws. Replace the batteries when the low-battery icon blinks on the LCD. Note Before replacing the batteries, turn the meter off. Meter On and Off 1. Press POWER to turn the meter on/off 2. The meter will automatically turn off after ten minutes of inactivity. 5

CALIBRATION Before beginning the calibration procedure, locate the two calibration solutions and keep them close to the meter. If the calibration is not performed quickly, the meter will return to test mode and the calibration will not hold. While this does not damage the meter, the calibration will have to be performed again. 1. Remove the 0NTU and 100NTU bottles from their protective cases. Tighten both caps and shake the bottles gently to ensure they are properly mixed. 2. Clean the outside of both bottles to ensure there are no fingerprints on the glass. Fingerprints or dirt on the glass will alter the readings, so it is critical to handle the bottles by the cap from this point on. 3. Turn the meter on. 4. Press and hold the TEST/CAL button until CAL appears on the screen. 5. Let go of the TEST/CAL button. The screen will display 0.0, prompting for the 0NTU standard solution. You will have 20 seconds to perform the next step or the meter will exit calibration mode and return to test mode. 6

6. Place the 0NTU bottle into the test chamber, lining the vertical white line of the bottle with the white dot on the meter. Close the lid and press the TEST/CAL button once. The meter will flash the word CAL on the screen for up to ten seconds. Note If the word Test appears on the screen, you did not perform step 6 fast enough and will need to repeat the process. 7. If the zero point calibration was successful, the meter will stop blinking and display the number 100, prompting for the 100NTU standard solution. Again, you will have 20 seconds to perform this step or the meter will exit calibration mode. 8. Place the 100NTU bottle into the test chamber, lining the vertical white line of the bottle with the white dot on the meter. Close the lid and press the TEST/CAL button once. The meter will flash CAL on the screen for up to ten seconds. Note If TEST appears on the screen, you did not perform the 100NTU point fast enough and will need to repeat the process. 9. If the calibration was successful, the screen will stop blinking and display 0.0, indicating that it is ready to test samples. 7

MEASUREMENT PROCEDURES For Single Point Readings 1. Pour test sample into one of the two included sample vials. 2. Gently shake the bottle to ensure the sample is properly mixed. If there is sediment in the sample that sinks to the bottle of the vial, the meter will not detect it. 3. Tighten the cap and clean the outside of the sample bottle with a lint free cloth. Be careful not to touch the glass as fingerprints can affect the readings. Handle the sample vial by the cap. 4. Place the sample vial in the test chamber, lining up the white line on the bottle with the white dot on the meter. 5. Press the TEST/CAL button once. For Multi Point Readings Multi-point mode produces the minimum and maximum values of a set of samples. This is especially useful in the case where there are slight changes in the turbidity of many samples or there is heavy sediment in a single sample. In the case of sediment, you can use this function to get a minimum and maximum reading based on how well the sample is mixed. Note This mode will only provide the minimum and maximum of the samples tested and will not internally store or recall the individual readings within that sample set. 1. Press the MIN/MAX button to enter multi-point mode. REC will appear in the upper right hand corner of the meter. 2. Prepare the test sample in the included sample vials and ensure they are clean, dry and free of fingerprints. 3. Place the test sample in the chamber and close the lid. 4. Press the TEST/CAL button once. The meter will display the turbidity value of the sample in NTU. 8

5. Repeat steps 3 and 4 for all samples. The meter can analyze up to 50 samples. 6. Press the MIN/MAX button when you are finished with all samples. After pressing the MIN/MAX button, no new values can be added to the set. 7. Press the MIN/MAX button as often as needed to display the minimum and maximum turbidity values of the data set in NTU. 8. Press and hold the Min/Max button to exit the Multi- Point mode. 9. After exiting, all values are cleared. Therefore, the next time you enter Multi-Point mode, the meter will only analyze the samples within the new set. Zero Point Adjustment This feature is used for low turbidity systems such as well water, tap water, or surface water from lakes and rivers. This method is effective for any solutions whose expected value is <2.0 NTU. The feature allows you to define a custom standard for the zero value. All successive measurements will be offset by this zero value. Note The Zero Adjustment is NOT a calibration. Calibration is performed using the 0NTU and 100NTU solutions as described on page 6. 1. Obtain a sample of your zero standard. This standard should be the lowest turbidity seen in your sample sets. For example, if you were testing a filtration system for drinking water, you would want to obtain a sample from the most successful filtration produced. 2. Place your sample in one of the included test bottles, tighten the cap and ensure the outside of the bottle is free of fingerprints. 9

3. Place the sample in the test chamber lining up the two white lines and close the lid. 4. Press and hold the ZERO button until ZERO appears on the LCD and release the button. 5. The screen will display 0.0 NTU. 6. All readings will be offset by the zero value until the meter is recalibrated or zeroed with the 0NTU standard. Data Hold The Minimum/Maximum functions on the meter are disabled during data hold. Also, new readings cannot be taken. 1. Press HOLD to freeze the reading on the display. Hold appears at the top of the LCD and the reading remains on the display until hold is disabled. 2. Press HOLD to return to Normal Mode. 10

CARE AND MAINTENANCE Never wash sample bottles with tap water. The residue left behind can alter readings. Use the included distilled water to clean the sample vials. Store the meter with the lid closed to prevent debris from entering the test chamber. Periodically wipe the meter with a dry, lint-free antistatic cloth. Do not use abrasives, solvents or cleaning agents containing carbon, alcohol or benzenes on the meter. Repairs or services not covered in this manual should be performed by qualified personnel only. Please contact Sper Scientific to speak with a technician. Periodically wipe the test chamber with a lint free cloth to ensure the internal lens is clean. SPECIFICATIONS Range Resolution Accuracy Turbidity 0 49.99 NTU 0.01 NTU ±5% RDG or 0.5 NTU, whichever is greater Operating Temperature and Humidity Power Supply Battery Life 50 1000 NTU 1 NTU ±5% RDG or 5 NTU, whichever is greater 0-50 C And less than 85% Relative Humidity AAA, 1.5V battery x 6 250 hours 11

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of one (1) year from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover sample vials, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will break the waterproof seal and void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 8281 E. Evans Rd., Suite #103 Scottsdale, AZ 85260 (480) 948-4448 The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperwarranty.com within 10 days of purchase. 12 rev. 3/15/2018