FINAL REPORT JANUARY 2006 REPORT NO

Similar documents
FINAL REPORT APRIL 2000 REPORT NO INCH ROCKET HYDRA PALLET MIL-STD-1660 FIRST ARTICLE TEST

FINAL REPORT OCTOBER 1996 REPORT NO ENHANCED WOOD PALLET WITH METAL BOTTOM ADAPTER MIL-STD-1660 TESTS

REPORT NO WOODEN BOX PALLET MIL-STD-1660 TESTS FINAL REPORT DECEMBER 1992 VALIDATION ENGINEERING DIVISION SAVANNA, ILLINOIS

EVT DTIC FOUR UNITS HIGH MIL-STD TEST OF PA 116 WOOD PALLET WITH TOP LIFT ASSEMBLY DRAWING (Final.

EVT DTIC S ELECTE AD-A MIL-STD-1660 TEST REVISED METAL VOLCANO PALLET AND TOP ADAPTER FINAL REPORT MARCH 1990

FINAL REPORT AUGUST 2005 REPORT NO A

FINAL REPORT December 2007 REPORT NO

REPORT NO. EVT DVIC AD-A MIL-STD-1660 TESTS ON (TEXS) Sz TACTICAL EXPLOSIVE SYSTEM FINAL REPORT AUGUST 1990

EVT llql. liiiililllllll11lql. IIIll/ I I i iiliii l/lli. Office of Project Manager for Ammunitlon Logistics AD-A FINAL REPORT ".

DTIC i i II I II 1 III 1111 AD-A EVT MIL-STD-1660 TESTING OF LAMINATED WOOD PALLETS JAN 17, 1992U

T C REPORT NO. EVT AD-A t MIL-STD-1660 TESTS FOR PA117 CONTAINERS ON METAL PALLETS WITH ADAPTERS

REPORT NO AD-A M621 PLASTIC CONTAINER. PERFORMANCE ORIENTED PACKAGING (POP) TESTn'TC FINAL REPORT MARCH 1992

REPORT NO POUND Ml17 BOMB TRANSPORTABILITY TESTS

ILE CTF REPORT NO. EVT M1IL-STD TESTS OF VOLCANO PALLET AND PALLET ADAPTER. -#ig; T I Cb AUGUST 1990

Testing Packaged Products Weighing More Than 150 Lbs.

The entire document shall be read and understood before proceeding with a test.

FINAL REPORT MAY 2005 REPORT NO

DTIC S ELECTE APR omay 1988 EVT ENGINEERING TEST OF PRO-FORM

DTIC ELECTE APR I T) "slksbf mvs E D EVALUATION DIVISION SAVANNA, ILLINOIS I-I II ng. ... w to u " US A R M Y

The entire document shall be read and understood before proceeding with a test.

Qualification Test of Prototype Container, Shipping and Storage, for Expended F/A-18 Fuel Cell No. 4

OVERVIEW OF PROCEDURE 2B

DTIC UFEB REPORT NO AD-A PROGRAM (AIEP) SUGGESTION NO. AMV EVALUATION OF ARMY IDEAS FOR EXCELLENCE FINAL REPORT

FINAL REPORT MAY 2007 REPORT NO

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

S ELECTE DTIC NNE REPORT NO TOW MISSILE PALLET MIL-STD-1660 TESTS. FINAL REPORT C U ow AUGUST 1993 FEB

E g DTIC REPORT NO / AD-A MM AMMUNITION PA120 CONTAINER PALLET RAIL IMPACT TEST FINAL REPORT DECEMBER 1991 ELECTE

OVERVIEW OF PROCEDURE 2A

MILITARY SPECIFICATION. This specification is mandatory for use by all Departments and Agencies of the Department of Defense. Classification 6.

First Article Testing of the USMC Container Consolidation Pallet Manufactured by Grate Pallet Solutions

Testing Packaged Products Weighing up to 150 Lbs.

Qualification Testing of the C-5 Mated Tire / Wheel Shipping Crate

Author: Kerry J. Libbert Mechanical Engineer. Performing Activity: Naval Surface Warfare Center Code 4045 Crane, Indiana

Package Testing Guidelines for Large Packages

The entire document shall be read and understood before proceeding with a test.

UNITIZATION PROCEDURES FOR 5.56MM OR 7.62MM CARTRIDGES PACKED IN SURE-PAK CONTAIN- ERS FOR INTRA-THEATER GROUND MOVEMENT ONLY

Standard Practice for Performance Testing of Shipping Containers and Systems 1

DTIC I(IELECTE AM. 111 i EIii N. UI ll AD-A38 015ODODPOPHM/USA/OOD/NAOTR AD-A

Standard Specification for Aluminum-Coated Steel Chain-Link Fence Fabric 1

Standard Specification for Steel Welded Wire Fabric, Plain, for Concrete Reinforcement 1

HEADQUARTERS, DEPARTMENT OF THE ARMY

CCSB Contact: Larissa A. Franklin Telephone (703) Item Description Class

(4) Production inspection is the inspection that must initially be conducted on each newly manufactured IBC.

This document is an OVERVIEW ONLY


PUBLIC SAFETY (661) Notice of Intended Action. Pursuant to Iowa Code section 103A.7, the Building Code Commissioner hereby

Mirror Packaging Supplement

SPECIFICATION FOR NICKEL ALLOY FORGINGS

Reference: ISTA pre-shipment testing

MILITARY SPECIFICATION COATING COMPOUND, SYNTHETIC RUBBER, FOR EXPOSED STEEL SURFACES

Shake. Rattle. Roll. Would you do this to your products?

DEPARTMENT OF DEFENSE DESIGN CRITERIA STANDARD AMMUNITION UNIT LOADS

Light Duty Ramps. Loadingdocksupply.com PHONE:

GLOBAL LVL HEADERS, BEAMS AND COLUMNS. 1.9E-2850Fb. 1.9E-2850Fb. User guide User guide. lvlglobal.com

Staff Contact: Erin N. Topper Telephone (703)

FedEx Procedures for Testing Packaged Products 150 lbs. or Less

WIREBOUNO BOX FOR SMAW ROCKETS MECHANICAL ENGINEER. PerfornIng Activity: Crone Division Naval Surface Warfare Center Crane, Indiana

PERFORMANCE SPECIFICATION COATINGS, POWDER (METRIC)

SpaceInvader pallet rack Manual. Scan QR code or go to to view a practical video introduction

Machine description / technical specifications: Lantech strech wrapper Q-300

DECK PERMIT APPLICATION

Package Testing Guidelines for Small Packages

Important Instructions

CRD-C Standard Test Method for Comparing Concretes on the Basis of the Bond Developed with Reinforced Steel

STORAGE SPACE EFFICIENCY GUIDE A DEMONSTRATION IN SPACE

rar-aep IExp Date Jun IForm Approved None N/A Packaging Division, AED LMAR-AEP None Engineering Center Picatinny Arsenal, NJ None -

Can Process Scrap Specification

Standard Specification for Welded Stainless Steel Mechanical Tubing 1

XI'AN LINKUN STEEL PIPE CO., LTD

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2)

ITEM 555 CHAIN LINK FENCING

VIBRATING CONVEYORS MODEL VMC

TEST REPORT ON. TESTED FOR: Central States Manufacturing, Inc. 302 Jane Place Lowell, AR Telephone: (800) Fax: (800)

Standard Specification for Welded Stainless Steel Mechanical Tubing 1

Product Application Guidelines. Platform Scales

DETAIL SPECIFICATION SHELTER, ELECTRICAL EQUIPMENT (WITH OR WITHOUT EQUIPMENT), PACKAGING OF

GHSP Supplier Packaging Requirements and Guidelines

i HllillillUETTINPG [li H AD-A

GUIDE FOR EVALUATING BLAST RESISTANCE OF EXISTING UNDEFINED ARCH-TYPE EARTH-COVERED MAGAZINES

Roughneck Mesh Slings

OUR COMPANY OUR WARRANTY OUR GUARANTEE

Unloading Handling Storage

This document is an OVERVIEW ONLY

ITEM 461 STRUCTURAL PLATE STRUCTURES. Galvanized steel plates shall conform to AASHTO M167 and aluminum plates shall conform to AASHTO M219.

Author: Kerry J. Libbert Mechanical Engineer. Performing Activity: Naval Surface Warfare Center Code 4045 Crane, Indiana Date.

CONTACT: CONTACT S NUMBER OF POSITIONS / BAYS:

DETAIL SPECIFICATION SHEET INTERCONNECTING BOX, FIBER OPTIC, SPLICE TRAY HOLDER MODULE, 8 TRAY

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

SK3000 Structural Pallet Rack Installation and Assembly Manual

General Information Series No. 755

Scope. resistance expressed as a moment

RR-F-191/3D 14 May SUPERCEDING RR-F-191/3C July 22, 1981 FEDERAL SPECIFICATION SHEET

FINAL REPORT MARCH 2005

7.1 Wood/Lumber/Board Storage 7.2 Flat Glass 7.3 Steel Formwork/ Plates/Coils 7.4 Paper Storage 7.5 General Requirements

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

Instructions for the use of the Link 4 Pallet Rack Lifter (PRL) model 5000

MILITARY SPECIFICATION DETONATOR, STAB, M55 LOADING, ASSEMBLING AND PACKING. MIL-D WAS INACTIVATED ON 10 July 1996 FOR NEW DESIGN

Downloaded from SPECIFICATION GENERAL SPECIFICATION FOR

Transcription:

FINAL REPORT JANUARY 2006 REPORT NO. 06-01 40" X 48" COLLAPSIBLE QUICK-CRATE CONTAINER, MIL-STD-1 660 TESTS, "DESIGN CRITERIA FOR AMMUNITION UNIT LOADS" Prepared for: Distribution Unlimited League Manufacturing 608 Furman Road P.O. Box 3626 Greenville, SC 29608-3626 DEFENSE AMMUNITION CENTER VALIDATION ENGINEERING DIVISION MCALESTER, OKLAHOMA 74501-9053 DT3TNF -7UT ýw TA j or P,.bIic h, 7 ease u cioi IuIonIO Uflirnied

"AVAILABILTY NOTICE A copy of this report will be furnished each attendee on automatic distribution. Additional copies or authority for reprinting may be obtained by written request from: Director U.S. Army Defense Ammunition Center ATTN: SJMAC-DEV 1 C Tree Road, Bldg. 35 McAlester, OK 74501-9053 DISTRIBUTION INSTRUCTIONS Destroy this report when no longer needed. Do not return. endorsement. Citation of trade names in this report does not constitute an official purposes. The information contained herein will not be used for advertising

REPORT NO. 06-01 JANUARY 2006 40" X 48" COLLAPSIBLE QUICK CRATE CONTAINER, MIL-STD-1660 TESTS, "DESIGN CRITERIA FOR AMMUNITION UNIT LOADS" ABSTRACT The U.S. Army Defense Ammunition Center (DAC), Validation Engineering Division (SJMAC-DEV) conducted MIL-STD-1660 Tests, "Design Criteria for Ammunition Unit Loads" on the 40" x 48" Quick Crate Container manufactured by League Manufacturing, from Greenville, SC. Two (2) containers were tested with a load of 4,055 lbs. each. The tests accomplished on the test units were the stacking, vibration, drop, incline impact, forklift handling, and disassembly tests. The containers passed all requirements with no significant problems encountered. As a result of the performance of the container, the 40" x 48" Quick Crate Container manufactured by League Manufacturing is suitable for United States Army use in such applications as retrograde repacking operations. Prepared by: Reviewed by: JEFFERY L. DUGAN Validation Engineer JERRY W. BEAVER Chief, Validation Engineering Division

U.S. ARMY DEFENSE AMMUNITION CENTER VALIDATION ENGINEERING DIVISION MCALESTER, OK 74501-9053 REPORT NO. 06-01 40" x 48" COLLAPSIBLE QUICK CRATE CONTAINER, MIL-STD-1660 TESTS, "DESIGN CRITERIA FOR AMMUNITION UNIT LOADS" TABLE OF CONTENTS PART PAGE NO. 1. IN T R O D U C T IO N... 1-1 A. B A C K G R O U N D... 1-1 B. A U T H O R IT Y... 1-1 C. O B J E C T IV E... 1-1 D. C O N C L U S IO N... 1-1 2. A T T E N D E E S... 2-1 3. T EST P R O C E D U R ES... 3-1 4. T E S T E Q U IP M E N T... 4-1 5. T E S T R E S U LT S... 5-1 6. D R A W IN G S... 6-1

PART 1 - INTRODUCTION A. BACKGROUND. The U.S. Army Defense Ammunition Center (DAC), Validation Engineering Division (SJMAC-DEV) conducted MIL-STD-1660 Tests, "Design Criteria for Ammunition Unit Loads" on the 40" x 48" Quick Crate Container manufactured by League Manufacturing, Greenville, SC. Two (2) containers were tested with a load of 4,055 lbs. each. The tests accomplished on the test units were the stacking, vibration, drop, incline impact, forklift handling, and disassembly tests. The unitization procedures were provided by DAC, Transportation Engineering Division (SJMAC-DET). B. AUTHORITY. This test was conducted law mission responsibilities delegated by the U.S. Army Joint Munitions Command (JMC), Rock Island, IL. Reference is made to the following: 1. AR 740-1, 15 June 2001, Storage and Supply Activity Operation 2. OSC-R, 10-23, Mission and Major Functions of U.S. Army Defense Ammunition Center (DAC) 21 Nov 2000. C. OBJECTIVE. The objective of the tests was to determine if the 40" X 48" Quick Crate Container met the MIL-STD-1 660 test requirements prior to the acceptance of the unitization procedures by the U.S. Army. D. CONCLUSION. The containers passed all tested requirements with no significant problems encountered. As a result of the performance of the container, the 40" x 48" Quick Crate Container manufactured by League Manufacturing is suitable for United States Army use in such applications as retrograde repacking operations. 1-1

PART 2 - ATTENDEES DATE PERFORMED: Test Unit #1- December 14, 2005 Test Unit #2- December 15, 2005 Test Unit #3- Not Tested ATTENDEE MAILING ADDRESS Jeff L. Dugan Director General Engineer U.S. Army Defense Ammunition Center DSN 956-8090 ATTN: SJMAC-DEV (918) 420-8090 1 C Tree Road, Bldg. 35 McAlester, OK 74501-9053 Fraser League League Manufacturing Company Representative 608 Furman Road (864) 232-4423 P.O. Box 3626 Greenville, SC 29608-3626 2-1

PART 3 - TEST PROCEDURES MIL-STD-1660 TEST. The test procedures outlined in this section from were extracted from the MIL-STD-1660. The tests are conducted on ammunition pallet units or unit loads and are summarized as follows: A. STACKING TEST. The test unit will be tested to simulate a stack of identical items stacked 16 feet high, for a period of one hour. This stacking load will be simulated by subjecting the specimen to a compression weight equal to an equivalent 16-foot stacking height. Photo 1 below shows an example of a unit load in the compression tester. Photo 1. Example of Stacking Test. (2.75-inch Hydra 70, PA151 Rocket Pallet in the Stacking Test.) B. REPETITIVE SHOCK TEST. The repetitive shock test is conducted law Method 5019, Federal Standard 101. The test procedure is as follows: The test unit will be placed on (not fastened to) the platform. With the test unit in one position, the platform will be vibrated at ½-inch amplitude 3-1

(1-inch double amplitude) starting at a frequency of approximately 3 cycles-persecond. The frequency will be steadily increased until the specimen leaves the platform. The resonant frequency is achieved when a 1/1 6-inch-thick feeler gage momentarily slides freely between every point on the specimen in contact with the platform at some instance during the cycle. Midway into the testing period, the specimen will be rotated 90 degrees, and the test continued for the duration. Unless failure occurs, the total time of vibration will be three hours. Photo 2 shows an example of the repetitive shock test. Photo 2. Example of the Repetitive Shock Test. (MSTF Low) C. EDGEWISE ROTATIONAL DROP TEST. This test is conducted using the procedures of Method 5008, Federal Standard 101. The procedure for the edgewise-rotational drop test is as follows: The test unit will be placed on its skids with one end of the pallet supported on a beam 6 inches high. The height of the beam will be increased as necessary to ensure that there is no support for the skids between the ends of the specimen when the dropping takes place, but should not be high enough to cause the specimen to slide on the supports when the dropped end is raised for the drop. The unsupported end of the specimen is then raised and allowed to fall freely to the concrete, pavement, or similar 3-2

unyielding surface from a prescribed height. Unless otherwise specified, the height of drop for level A protection will conform to the following tabulation: GROSS WEIGHT DIMENSIONS OF ANY HEIGHT OF DROPS (WITHIN RANGE EDGE, HEIGHT OR WIDTH ON EDGES LIMITS) (WITHIN RANGE LIMITS) Level A Level B (Pounds) (Inches) (inches) (Inches) 150-250 60-66 36 27 250-400 66-72 32 24 400-600 72-80 28 21 600-1,000 80-95 24 18 1,000-1,500 95-114 20 16 1,500-2,000 114-144 17 14 2,000-3,000 Above 145- No limited 15 12 Above - 3,000 12 9 Figure 1. Photo 3. Example of Edgewise Rotational Drop Test (MSTF Low) 3-3

D. INCLINE-IMPACT TEST. This test is conducted by using the procedure of Method 5023, Incline-Impact Test of Federal Standard 101. The procedure for the incline-impact test is as follows: The test unit will be placed on the carriage with the surface or edge to be impacted projecting at least 2 inches beyond the front end of the carriage. The carriage will be brought to a predetermined position on the incline and released. If it were desired to concentrate the impact on any particular position on the container, a 4- x 4-inch timber may be attached to the bumper in the desired position before the test. The carriage will not strike any part of the timber. The position of the specimen on the carriage and the sequence in which surfaces and edges are subjected to impacts may be at the option of the testing activity and dependent upon the objective of the test. When the test is to determine satisfactory requirements for a container or pack, and, unless otherwise specified, the specimen will be subjected to one impact on each surface that has each dimension less than 9.5 feet. Unless otherwise specified, the velocity at the time of the impact will be 7 feet-per-second. Photo 4 shows an example of this test. N Photo 4. Example of the Incline-Impact Test. (2.75-Inch, Hydra 70, PA151 Rocket Pallet on incline-impact tester.) 3-4

E. SLING COMPATIBILITY TEST. The test unit utilizing special design or non-standard pallets will be lifted, swung, lowered and otherwise handled as necessary, using slings of the types normally used for handling the unit loads under consideration. Slings will be easily attached and removed. Danger of slippage or disengagement when load is suspended will be cause for rejection of the specimen. F. FORKLIFTING TESTS. The test unit will be lifted clear of the ground by a forklift from the end of the test unit and transported on the forks in the level or back-tilt position. The forklift will pass over the Optional Rough Handling Course For Forklift Trucks as outlined in MIL-STD-1660. The course will consist of parallel pairs of 1-inch boards spaced 54 inches apart and will be laid flat wise on the pavement across the path of the forklift. One pair will be laid at an angle of approximately 60 degrees to the path so that the left wheel strikes first. Another pair will be laid securely across the path of the forklift so that the wheels strike simultaneously. Another pair will be laid at an angle of approximately 75 degrees to the path so that the right wheel strikes first. The test unit will be transported over the Optional Rough Handling Course. The test unit shall be observed for deflection and damage. The test unit will be rotated 90 degrees and the test unit lifted from the side and the above steps repeated. 3-5

PART 4 - TEST EQUIPMENT A. COMPRESSION TESTER. 1. Manufacturer: Ormond Manufacturing 2. Platform: 60- x 60-inches 3. Compression Limit: 50,000 pounds 4. Tension Limit: 50,000 pounds B. TRANSPORTATION SIMULATOR. 1. Manufacturer: Gaynes Laboratory 2. Capacity: 6,000-pound payload 3. Displacement: 1/2-inch amplitude 4. Speed: 50 to 400 RPM 5. Platform: 5- x 8-foot C. INCLINED PLANE. 1. Manufacturer: Conbur Incline 2. Type: Impact Tester 3. Grade: 10 percent incline 4. Length: 12-foot 4-1

PART 5 - TEST RESULTS 5.1. TEST UNIT DATA. The test units were inertly loaded to the specified design weight using M548 Cans loaded with inert material. The test units were prepared using the unitization procedures specified in Part 6 - Drawings. Special care was taken to ensure that each M548 ammunition can had the proper amount of weight in order to achieve a realistic pallet center of gravity (CG). Once properly prepared, Test Units #1 and #2 were tested using MIL-STD-1660 requirements. Test Unit #3 was not tested. TEST UNIT #1 40" x 48" COLLAPSIBLE QUICK CRATE CONTAINER Test Date: Gross Weight: Length: Width: Height: Mfgr: 14 December 2005 (MIL-STD-1660) 4,055 pounds 40 inches 48 inches 50-1/2 inches League Manufacturing, Greenville, SC TEST UNIT #2 40" x 48" COLLAPSIBLE QUICK CRATE CONTAINER Test Date: Gross Weight: Length: Width: Height: Mfgr: 15 December 2005 (MIL-STD-1660) 4,055 pounds 40 inches 48 inches 50-1/2 inches League Manufacturing, Greenville, SC 5-1

A. MIL-STD-1660 TEST RESULTS TEST UNIT #1: 1. STACKING TEST. The test unit was compressed with a load force of 12,165 pounds for 60 minutes on 14 December 2005. No damage was noted as a result of this test. See Photo 5 of the test unit in the compression unit. Photo 5. Test Unit in the Stacking Test. 2. REPETITIVE SHOCK TEST. The test unit was vibrated 90 minutes at 222 RPM in the longitudinal orientation and 90 minutes at 185 RPM in the lateral orientation on 14 December 2005. No damage was noted as a result of this test. Photo 6 shows the test unit on the vibration platform. 5-2

Photo 6. Test Unit During Repetitive Shock Testing. 3. EDGEWISE-ROTATIONAL DROP TEST. The test unit was edgewise rotationally dropped from a height of 12 inches on both longitudinal sides and both lateral sides. No significant damage was noted as a result of this test; however, the test unit sustained minor damage to the bottom skids and the top deck during drop testing. The damage was deemed minor because it would not interfere with the container safely continuing on with its intended mission. The minor damage that occurred is common to this type of container with the 4,000-lb. load capacity. Photo 7 shows the test unit during the edgewise drop test. Photo 8 shows the minor damage sustained during the drop tests. 5-3

Photo 7. Edgewise Drop Test on the Test Unit. Photo 8. Minor Damage Sustained During Drop Test. 4. INCLINE-IMPACT TEST. The test unit was impact tested on both longitudinal sides and both lateral sides. No significant damage was noted as a result of this test. See Photo 9 for the specimen during the lateral incline-impact test. 5-4

Photo 9. Incline-Impact Testing of the Test Unit. 5. SLING COMPATIBILITY TEST. N/A 6. FORKLIFTING TEST. The test unit was lifted clear of the ground by a forklift from both longitudinal sides and both lateral sides and transported on the forks. Photo 10 shows the test unit during the Forklifting Test. No damage was noted as a result of this test. 5-5

Photo 10. Test Unit During the Forklifting Test 7. DISASSEMBLY TEST. Inspection revealed no damage. 8. CONCLUSION. No major problems were encountered during the completion of the required testing. The test unit passed the requirements of the MIL-STD-1660. B. MIL-STD-1660 TEST RESULTS'TEST UNIT#2: 1. STACKING TEST. The test unit was compressed with a load force of 12,165 pounds for 60 minutes on 15 December 2005. No damage was noted as a result of this test. 2. REPETITIVE SHOCK TEST. The test unit was vibrated 90 minutes at 222 RPM in the longitudinal orientation and 90 minutes at 185 RPM in the lateral orientation on 15 December 2005. No damage was noted as a result of this test. 5-6

3. EDGEWISE-ROTATIONAL DROP TEST. The test unit was edgewise rotationally dropped from a height of 12 inches on both longitudinal sides and both lateral sides. Identical minor damage was sustained as was noted for Test Unit #1 during the drop test for Test Unit #2. 4. INCLINE-IMPACT TEST. The test unit was impact tested on both longitudinal sides and both lateral sides. No significant damage was noted as a result of this test. 5. SLING COMPATIBILITY TEST. N/A 6. FORKLIFTING TEST. The test unit was lifted clear of the ground by a forklift from both longitudinal sides and both lateral sides and transported on the forks. No damage was noted as a result of this test. 7. DISASSEMBLY TEST. Inspection revealed no damage 8. CONCLUSION. No major problems were encountered during the completion of the required testing. The test unit passed the requirements of the MIL-STD-1660. 5-7

PART 6 - DRAWINGS The following drawing represents the load configuration that was subjected to the test criteria. 6-1

MIL-STD 1660 TESTING OF THE QUICK CRATE CONTAINER THIS THREE PAGE DOCUMENT DEPICTS PROCEDURES FOR UNITIZING M548 CONTAINERS IN THE QUICK CRATE CONTAINERS. Prepared during December 2005 by: U.S. Army Defense Ammunition Center ATTN: SJMAC-DET McAlester, OK 74501 POC: Mr. Michael Bartosiak DSN 956-8083 Comm (918) 420-8083 Fax 956-8811 E-mail: michael.bartosiak@dac.army.mil Laura Fieffer Acting Chief, Transportation Engineering Division

3812 4-4-314' 4434 SIDE END 40" -5-47" FIBERBOARD CENTER FILL 36-3/4: X 43-1/12: X 1/21, FIBERBOARD SIDEFILL1 46-12" XBETWEEN 43-12" X1/2"LAYERS. INTERMEDIATE FILL 2 SHETS ECID36-3/4' X BETWEEN 43-1/2" X 1 r2f LAYERS.FIBERBOARD SHEETREQOD FIBERBOARD 2 SHEET REQD M548 METAL BOX m548 BOXES AT 126 LB EACH -- 30 REQD - - - 3780 LBS 30 REDD. FIBERBOARD, 1/2'------139. 11'REQO - - - 12 LBS PAGE 2 TEST LOAD TEST SKETCH

TIEDOWN STRAP 3/4" X.035" OR.031" X 15'-3" LONG STEEL STRAP- PING (3 REQD). SEE NOTES 1 AND 2 BELOW. SEAL FOR 314" STRAPPING (7 REQD, 1 PER STRAP). CRIMP EACH SEAL WITH TWO PAIR OF NOTCHES. 49-1/2" HORIZONTAL STRAP, 3/4' X.035" OR.031" X 15'-8" LONG STEEL STRAPPING (2 REQO). SEE NOTES 1 AND 2 ON BELOW. LOAD STRAP, 314" X.035" OR.031" X 16'-7" LONG STEEL STRAPPING (2 REQO). SEE NOTES 1 AND 2 BELOW. PALLET UNIT QUICK CRATE UNIT DATA 30 M548 BOXES AT 126 LBS EACH ---------- 3,780 LBS DUNNAGE ------------------------------- 22 LBS PALLET BOX ---------------------------- 260 LBS TOTAL WEIGHT ----------- 4,062 LBS CUBE ------------------ -55,.0 CU FT NOTES: 1. WHEN APPLYING ANY STRAP, CARE MUST BE EXERCISED TO ASSURE THAT THE END OF THE STRAP ON THE UNDERSIDE OF THE JOINT EXTENDS AT LEAST 6" BEYOND THE SEAL. THE EXTRA MINIMUM LENGTH OF STRAP IS REQUIRED TO PERMIT SUBSEQUENT TIGHTENING OF LOOSENED STRAPPING. 2. INSTALL EACH HORIZONTAL, LOAD, AND TIEDOWN STRAP TO BE LOCATED AS SHOWN. HORIZONTAL STRAPS MUST BE TENSIONED AND SEALED PRIOR TO THE APPLICATION OF TIEDOWN AND LOAD STRAPS. LOAD STRAPS MUST BE TENSIONED AND SEALED AFTER THE HORIZONTAL STRAPS AND PRIOR TO THE TIlEDOWN STRAPS. BILL OF MATERIAL PALLET BOX, QUICK CRATE - -- 1 REQO - - - 260 LBS STEEL STRAPPING, 3/4" - - 110. 25' REQD - - - 9. 84 LBS SEAL FOR 3/4" STRAPPING - - - 7 REQD - ---- NIL FIBERBOARD, 1/2" 139. 11' REQD - - -11. 61 LBS PAGE 3 TEST SKETCH