Wear debris measurement

Similar documents
Industrial Solutions

Ferrography/oil analysis: An excellent condition monitoring technique

Oil Analysis vs. Microscopic Debris Analysis - When and Why to Choose

CSI Oil Analysis Options

Fluid Analysis for Bearing Reliability

Wear Particle Atlas CD-ROM

Test It, Don t Change It On-site Oil Analysis Solutions. Candice Brown, Spectro Incorporated

Ferrography A procedure for measuring wear rate

OIL/WEAR PARTICLE ANALYSIS A PREDICTIVE MAINTENANCE TOOL

A Computerised Wear Particle Atlas for Ferrogram and Filtergram Analyses

OIL PURIFICATION SYSTEM

Oil Analysis Lessons Learned. Chad Norris Refrigeration Engineer Wells Dairy, Inc.

EQUIPMENT PARTICLE ANALYSIS

DTIC. Technical Information Center Iw Compilation Part Notice. This paper is a part of the following report:

Predictive Maintenance (PdM) & Proactive Maintenance (PAM) Dr. Khaleel Abushgair

Importance of condition monitoring:

Fluid Analysis. What Can Fluid Analysis Do For You? Suggested Sampling Intervals and Methods

Air, moisture, heat and particulates are among the enemies threatening the performance and life of your machinery.

Lubricant management for non-circulating sumps

Basics of Oil Condition Monitoring Through Oil Analysis Marian Kiley Key Account Manager Analysts, Inc.

Detection of Abnormal Wear Particles in Hydraulic Fluids via Electromagnetic Sensor and Particle Imaging Technologies

Laboratory Grease Analysis with Grease Thief Sampling & Analysis System

Predictive Maintenance by Oil and Fuel Analysis

How to ensure proper oil cleanliness in lubrication systems

Between "ferrogram" and "filtergram" makers is the multiple centrifiltergram maker: a new technique for solid debris separation

Services SAMPLE SUMMARY REPORT DR. PUMP, LLC Isuzu Rodeo. Atlanta, GA 05/24/2007

The real reasons why. And strategies to stop problems before they start.

BEST PRACTICES FOR AN EFFECTIVE OIL ANALYSIS PROGRAM

Understanding Oil Analysis: How It Can Improve Reliability of Wind Turbine Gearboxes Michael P. Barrett and Justin Stover

Condition Monitoring Services for Today s Demands

Introduction. Adverse Affects

Used Oil Analysis Data from Wind Turbine Gear Reducers Helps Define Achievable Oil Drain Intervals

oil cleaner Electrostatic Product brochure

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT:

FOCUS ON WIND TURBINES YOUR ADVANTAGE IN AN INDUSTRIAL WORLD

Par-Test. Fluid Analysis

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 2, Issue 5, November 2012

Diesel Engine Coolant Analysis, New Application for Established Instrumentation

Phosphate Ester Fluid Testing, Maintenance Challenges, and Solutions in EHC Systems

Oil Analysis Provides Information Vital to Determining Root Cause of Water Contamination in Industrial Gearboxes

FLUID CLEANLINESS OIL FILTRATION

T-700 DF 4110V PARTICULATE-WATER & FILMING REMOVAL FILTRATION ELEMENT

#287 FOOD GRADE FLUSHING AGENT

Benefits of running organic matrices using the Agilent 5100 ICP-OES fast, robust, high performance analysis

Day 1 - Machinery Health and Reliability Excellence - Introduction

Condition-Monitoring of Phosphate Ester

Examination of Analytical Conditions for Trace Elements Based on the Detection Limit of EPMA (WDS)

SERBIATRIB th International Conference on Tribology. Kragujevac, Serbia, May 2011 APPLICATION OF MOBILE DEVICE FOR OIL ANALYSIS

ADDITIVE DEPLETION: IMPACT ON USEABLE OIL LIFE AND EQUIPMENT WEAR

Technical Information Center. Distribulon Statement A: This document has been approved for public release and sale- its distribution is unlimited.

Integrating Grease Sampling and Analysis into Wind Turbine Maintenance

Filtration of Oil and Related Benefits

RIX3100. Fully Automated Sequential X-ray Spectrometer System. Product Information

LUBRICANTS FOR COMPACTION OF P/M COMPONENTS

Piedmont Chapter 14, Vibration Institute Meeting December 5, Midlands Technical College West Columbia, SC

OIL CLEAN-UP SYSTEMS & SKIDS

Xamine Oil Analysis Program User Guide

EDX 600. Atomic Absorption Spectrometry

X-Ray Fluorescence Measurements of Molten Aluminum Elemental Composition

HYDRO-ABRASIVE EROSION OF PELTON TURBINES

S8 TIGER Series 2. Lab Report XRF 144. Innovation with Integrity. Accurate Quality Control of Tool Steels XRF

Techniques for Detection of Surface Defects in Tubing and Pipe

The World s Most Versatile Filter System

WearSens WS3000 Oil Condition Monitoring System Wind Turbine Application

Characteristics of the Fine Grained CVD Diamond Film and its Industrial Applications. K. Kazahaya, A. Yamakawa and T. Fukunisi

Fluid Contamination Under Control...

Optical Emission Spectrometers

[ Wear Debris Analysis]

VHG Labs. Standards and Supplies for Spectrochemical Analysis QUALITY. TRACEABILITY. DEPENDABILITY. WORLDWIDE

Improving Machinery Productivity with Oil Debris Sensing

Method for estimating contamination factor, η c, based on lubricant cleanliness

Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

High Velocity Oil Flushing Contamination Control Oil & Fuel Purification Services

Particle characterization of Metal Powders with Dynamic Image Analysis

How to Choose Proper FTIR Spectroscopic Techniques to Analyze Petroleum Products. Presented by: Dr. Yanqia Wang

Choice of Test Machines

1. To learn and to gain experience in the preparation of metallographic specimens.

OTC PP. Measuring Oil in Water: A Sanity Check Lew Brown, Mason Ide, and Peter Wolfe, Fluid Imaging Technologies, Inc.

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Rexroth Oil Cleanliness Booklet

VEGETABLE MILKS. Via Don Battistoni, Jesi (AN) Italy Phone Fax

Lesson 1 Good Diffraction Data

Magnetic field. Figure 1. Wet drum magnetic separators for heavy media application. Self-levelling counter-rotation tank style.

EQUIPMENT REPAIR REPORT

2/8/2018. Friction. The Laws of Friction MSE 454 SURFACE TREATMENT OF MATERIALS. Ing. Anthony Andrews (PhD) Friction testing. Why is there friction?

Development Of Condition Based Maintenance For Coal Handling Plant Of Thermal Power Stations. By: Makarand M. Joshi

OFFLINE FILTRATION SERVICE

Parker Kittiwake Condition Monitoring Products

Creating an effective lubrication survey

Metals Analyzer. OES 6000 Optical Emission Spectrometer. fast and accurate metal analysis

Understanding grease construction and function

NSK Premium Technology For Wind

Water Droplet Impingement Erosion (WDIE) Water Droplet Impingement Erosion (WDIE) Solid Particle Erosion. Outline

Innovative technologies for gas turbine air filtration

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Oil analysis in wind turbine gearboxes

Contractor-based lubrication programs

THE SECRET S. Filter debris analysis and differential pressure monitoring can reveal pending disaster and help prevent it.

Monitoring of Wind Turbine Gearbox Condition through Oil and Wear Debris Analysis: A Full-Scale Testing Perspective

Premature bearing failures in wind turbine gear units

Transcription:

Best Practices Mike Johnson Third of a five-part series on oil analysis (January, April, May, July & October) Wear debris measurement Before examining your machine s health, consider both quantitative and qualitative testing methods. Key Concepts Wear debris progresses through stages of intensity with particles growing larger at each stage. Observation of wear particles can provide optimum insight into the wear mode and degree of advancement. Ferrous density and imaging methods should be used to supplement spectrometric methods. Oil analysis provides value that can be characterized as both short- and long-term. For most, oil analysis is oriented toward the short-term focus on oil health (use of analysis to manage lubricant changes). While certainly there is value to be derived from this approach, there is greater value to be found in system analysis. System analysis includes interest in oil and machine health and the presence of lubricant defects (contaminants, wrong lubricant) that are known to promote lubricated component failure. When turned into system analysis, a clear focus on machine health provides tremendous long-term benefit but still preserves the short-term benefit associated with lubricant change management. In Part III of this five-part series, we examine information that the reliability engineer would consider for gauging changes in machine health through wear debris analysis. Wear Debris Progression Machine surfaces don t typically progress instantaneously from a passive wear to catastrophic wear states. A physically fit machine progresses through stages of increasing wear intensity, with the increase measurable in both wear particle concentration and particle size and shape (particle morphology). Research conducted at the Oklahoma Fluid Research Center

Figure 1 Wear debris particle size increases with intensity (Courtesy of AMRRI) provides a frame of reference for increasing particle size with increasing wear intensity, as shown in Figure 1. 1 Accordingly, instrument manufacturers recommend the routine use of technologies that identify both early- and latestage wear generation and follow-on methods to characterize the debris in order to isolate the mode and component responsible for the debris. Quantification vs. Characterization The intensity of a machine wear problem can be reflected by increase in both concentration and size of wear particles, but this alone does not provide adequate insight for machine health and preservation. The most common emission spectrometric techniques (plasma, arc emission) used for wear debris analysis are highly preferential to small particle size and consequently work most effectively for machines operating in a normal state producing lowlevel wear. If used exclusively, these may miss early symptoms of a change in wear state. No single technique can cover the whole range of particle sizes that can be generated as the wear rate increases. Therefore, either the method used must be selected on the basis of past experience of likely failure or several methods must be used. 2 For a variety of organizational reasons (too much change, weaknesses in long-term data management, weaknesses in long-term focus on reliability management, etc.), identifying pre-existing root causes and having a clear sense of which techniques to use based on historical failure rate is rare. It is best to understand all the common techniques applied to sample-based analysis, their respective strengths and weaknesses and where each technique s effectiveness ends and another begins. Concentrated wear debris collection and A physically fit machine progresses through stages of increasing wear intensity. analysis (sump residue, filter element dissection, magnetic residue) and online (continuous) analysis techniques also provide essential insight into machine health. Quantitative Detection Techniques Quantitative detection techniques could be separated into those that are suited best for fine particle and coarse particle recognition. Fine particle recognition techniques include: Emission Spectroscopy. There are several types of spectrometers used in lubricant analysis. The most common are the Inductively Coupled Plasma and Arc Emissions Spectrometers. The spectrometers are capable of reporting the concentration of between 15 and 23 elements, depending on configuration. Both are widely used and highly reliable reporting wear debris occurring at very low particle sizes. The caveat for ICP/AE spectrometers is their well-known lack of sensitivity to particles above roughly 3-7 microns and virtually no sensitivity to particles above 10 microns. X-ray Spectroscopy. Also called X-ray fluorescence (XRF), there are two types of x-ray spectrometer designs used for oil analysis: energy and wavelength dispersive. With this technique, the sample is bombarded by gamma rays (Xrays). Secondary or fluorescent x-rays are produced, measured and quantified by the instrument. In both instances, XRS methods do not have particle size limitations inherent in emission spectrometers or the added time for sample preparation. Particle Counting (PC). Conducted according to ISO 11171, particle counting provides for the measurement of particles in ranges including >4 µm (micrometers), >6 µm, >14 µm, >21 µm, >38 µm and >70 µm. If observed through all five stages, PC technique could give a clear indication in increase in wear particle sizes. Regrettably, reporting the large particle concentrations is often neglected. Additionally, many lubricant analysis labs do not include PC tests in standard test slates for samples other than low viscosity circulation (hydraulic, turbine) systems. Particularly for industrial machines that tend to generate large populations of abrasive, adhesive, cutting, sliding and fatigue debris well above the 14 µm range, this is an opportunity missed. Rotrode Filter Spectroscopy (RFS). Rotrode filter spectroscopy is similar in nature to the AES technique noted earlier. However, in this instance the oil is filtered through the rotating disk, the debris is captured, the oil is washed away and the remaining debris is vaporized by electrical arc. This approach reveals higher overall concentrations of large wear by volatizing large particles and removes influences from oil 1 Fitch, E.C. (1992), Proactive Maintenance for Mechanical Systems, FES, Inc. 2 Wright, G.J., and Neale, M.J. Wear-Debris Analysis as an Integral Component of Machinery Condition Monitoring, Journal of the South African Institute of Mining and Metallurgy, August 1987. 3 Lukas, M., and Anderson, D. Analytical Tools to Detect and Quantify Large Wear Particles in Used Lubricating Oil, Page 2, Spectro, Inc. 4 Ibid. 2 MAY 2011 TRIBOLOGY & LUBRICATION TECHNOLOGY WWW.STLE.ORG

The intensity of a machine wear problem can be reflected by increase in both concentration and size of wear particles. type and viscosity, sample size and particle morphology. 3 The most recent RFS design provides results in scalar units where early designs are reported in parts per million. ASTM and ISO standards for operating these methods produce reporting in standardized concentration units. Spectrometers report values in parts per million. Particle counters report values in particles per milliliter. When the test is conducted according to standard methods, the reporting units are consistent between different instruments, even if the exact values differ. Ferrous density analysis is a method that reports a relative quantity of ferrous debris found in the sample volume. As would be expected, this type of test works best on machines that have significant amounts of metallic surface interactions such as multi-bearing and gear-driven machines. There are several methods including direct read ferrography and particle quantifier (Rotary or Hall Effect types). These techniques are also quantitative (report numerical values) but do not report in standardized units. Laser Net Fines is a wear debris density method that can provide results in both absolute (particles per milliliter per ISO 11171) and relative (particle imaging) terms. Direct Read (DR) Ferrography. This method was developed in the 1970s to provide a means to address particle size detection weaknesses with spectrographic methods. The technique measures concentration of both large and small ferrous wear debris in an oil sample. 4 DR ferrography is performed by passing the sample through a treated glass tube that is positioned over a high gradient magnetic field, as shown in Figures 2 and 3. Larger ferromagnetic particles are deposited at the oil entry side, and the smaller particles that are less susceptible to the magnetic field are deposited toward the exit side. Light sensors mounted at each end of the tube are used to transmit light through the debris field. Photo detectors measure the amount of light passing through the field and assign Formulate Green With Fruits &Beans Figure 2 Schematic of a DR Ferrograph (Courtesy of AMRRI) Palm Based Oleochemicals&Derivatives: Fatty Acids Glycerine Fatty Alcohols Fatty Acid Esters Fractionated Methyl Esters (C610, C8, C10, C12, C1214, C14, C16, C1618, C18) Castor Oil&Derivatives: 12 Hydroxy Stearic Acid CO Fatty Acid Hydrogenated Castor Oil Ricinoleic Acid Methyl 12 Hydroxy Stearate Sebacic Acid Visit our NewWebsite: www.acme-hardesty.com Call us for afree Oils &Fats Composition Chart Figure 3 Diagram showing the accumulation of ferrous debris in the precipitator tube according to size. (Courtesy of AMRRI) Acme-Hardesty Co. 450 Sentry Parkway East Blue Bell, PA 19422 866.226.3834 WWW.STLE.ORG TRIBOLOGY & LUBRICATION TECHNOLOGY MAY 2011 3

concentration values for small debris (DS for particles 5 microns) and large debris (DL for particles 5 microns). Once the concentrations of small and large particles are determined, the ratio of large to small particles (percent large particles PLP) and the total wear particle concentration (WPC) also are reported. The weak magnetic nonferrous particles also can deposit on the slide, but their deposition is not a function of size. They may be found at any location on the slide. Depending on the conclusions (WPC, PLP), slide review may extend to a microscopic analysis called analytical ferrography. Particle Quantifier (PQ). The particle quantifier (PQ) exposes the lubricant to a magnetic field (the Hall Effect), as shown in Figure 4. The presence of ferrous debris causes a distortion in the field, which is represented as the PQ Index Value (vs. two values provided by the DR technique). The value is an arbitrary unit of measurement that correlates well with DR Ferro large but does not correlate directly to other wear debris units of measurement. If the PQ Index Value is smaller than iron parts per million (ppm) reported by AES/ICP, the concentration of particles larger than 10 microns is expected to be small. If the PQ Index increases dramatically while the ICPs iron parts Figure 4 The POLARIS Laboratories technique for use of the PQ instrument to clarify wear intensity. (Courtesy of POLARIS Laboratories) per million (ppm) remains consistent or goes down, larger ferrous particles are being generated. Analytical ferrography should then be used to qualify the type of wear occurring. 5 5 http://www.polarislabs1.com/test-explanations/particle-quantifying.php. Performance and service that are LEADING EDGE People and specialty products you can count on. SpectraSyn Ultra High VI Polyalphaolefin Base Oils Group IV SpectraSyn Plus Base Oils Group IV SpectraSyn Polyalphaolefin Base Oils Group IV Esterex Esters Group V Synesstic Alkylated Naphthalene Group V Ultra-S Base Oils Group III Pure Performance Base Oils Group II ConoPure Process Oils Global Sales and Service 7010 Mykawa Houston, Texas 77033 800.228.3848 www.jamdistributing.com Esterex, SpectraSyn, SpectraSyn Ultra and Synesstic are trademarks of Exxon Mobil Corporation. Ultra-S is a trademark and Pure Performance and ConoPure are registered by ConocoPhillips Company. WWW.STLE.ORG TRIBOLOGY & LUBRICATION TECHNOLOGY MAY 2011 5

Figure 5 Laser Net Fines system operation overview. (Courtesy of Spectro, Inc.) Figure 6 LNF shape classification and reporting display (Courtesy of Spectro, Inc.) The next generational step for particle quantification using the Hall Effect is characterized by the Kittiwake Instruments fdmplus. This method accounts for all metallic iron and its magnetic alloys by surveying the entire fluid contents of the sample. With a known fluid volume and iron concentration, PPM value can be reported. Laser Net Fines (LNF). The LNF instrument combines characteristics of viscosity measurement, particle counting and particle characterization into one instrument to provide users with a measurement of debris between 4 µm and 100 µm in size. Particles are sized and distributions are reported to the operator by ISO Code (>4 μm, >6 μm and >14 μm) and/or other codes such as the NAS Code (5 μm-15 μm, 15 μm-25μm, 25 μm-50μm, 50 μm-100μm and >100 μm). Particle quantification is enhanced with an imaging and comparative analysis technique that provides users with a pixel display of images over 20 µm and classifies debris images into five categories. Figure 5 provides a simplified look at the LNF test cell.6 As shown in Figure 6, a variety of particle shapes and sizes can be automatically reported, providing the analyst with the means to make a rapid determination about changes in wear intensity and wear mode. Qualitative Detection Techniques Looking for better performance? Choose Inolex for high purity synthetic esters. ;06*'6+% 56'4 #5' +.5 s Chain Lubricants (H1 available) s Greases s Compressor Fluids s Hydraulic Fluids s Metalworking Additives THE INTELLIGENT CHOICE The several instruments reviewed so far provide some method of quantifying the size and concentration of debris in the lubricant with varying degrees of resolution. Each has its strengths and weaknesses and can markedly add to the quality of the final output from the on-site or offsite lab. After measurement, if the change in the quantity and/or size of observed debris is significant (a plantspecific decision) then the remaining high-value action is to have the debris microscopically evaluated through a method known as analytical ferrography. Within this method, the analyst places a slide containing deposited debris in a powerful microscope for evaluation. Particles are characterized according to their size, shape, color, angularity, dimension (length to 6 6 MAY 2011 TRIBOLOGY & LUBRICATION TECHNOLOGY Laser Net Fines Reproducibility Test with Medium Test Dust, Spectro, Inc., Bulletin LNFC-08. WWW.STLE.ORG

width) and softness and also may be subjected to magnetic, light and heat treatment. This technique is time-consuming and requires that the instrument operator have appreciable experience to derive maximum benefit from the technique. Figure 7 illustrates how the operator may use magnification of deposited debris to identify evidence of a specific problem. test would be LNF. Particle counting can be done to identify concentrations of particles above the ICP/AES sensitivity range, but it is difficult. LNF is a strong option because of its reported ability to see through dark oils. If LNF is positive, then confirmation via analytical ferrography would be the last stage of analysis. This approach provides progressively revealing data that justifies the next step. Industrial machines and components normally degrade from seven common wear modes: 1. Abrasion 2. Adhesion 3. Corrosion 4. Fatigue 5. Erosion 6. Cavitation 7. Electrical discharge. Figure 7 A close-up examination of rubbing wear debris field reveals a sliding wear condition in a gearbox, with some instance of fatigue, as shown at 1000X. (Courtesy of Condition Monitoring International) Optimum Identification With the wide variety of tests available and the recognition that the routine wear debris tests (AES, ICP) do not fully represent wear conditions, the reliability engineer must make test slate selections that provide the maximum information for the available funds. There are several combinations of test packages that could effectively cover the particle size and concentration spectrum in one way or another. If the purpose of sample collection is to evaluate oil health, then adding any of the presented test methods will not add value. If the purpose is to measure system health, then one should ask about the failure modes and patterns of the particular system in question. Machines that experience high rates of small rubbing wear particles and corrosive wear debris, such as engines, are served well by spectrometric methods. If spectroscopy testing (ICP/AES) is positive for increase above an alarm threshold, then the first non-routine test would be RFS, effectively expanding identification of the entire array of engine metals including particles in the catastrophic range (>38 microns). If RFS results exceed an alarm limit, affirming a high concentration of large particles, then the next non-routine Wear particle sizes contributed by the first four modes are most common and tend to be large and are not fully represented by routine spectroscopic methods. 7 Test slates for circulating systems, drive trains, bearings (plain and element), hydraulic systems and plant service compressors should routinely include methods for identifying an acceleration in wear. These machine test slates should include spectrometric (ICP/AES), particle identification (PC) and ferrous concentration (DR Ferro/PQ) as routine methods. If a threshold alarm is exceeded in either ICP/AES and PQ, the next nonroutine test would be either LNF or Analytical Ferro, or perhaps both. Figure 8 provides a correlation between the test methods presented in this article and the particle sizes that each of these methods is capable of measuring. There is enough overlap between these methods and the hierarchal structure offered that most commercial labs should be able to provide coverage for the required tests. Also, there is enough overlap between the methods that no single course of action could be declared to be best. The reliability engineer must assess his service lab capabilities, the machine failure modes and must work to accomplish the broadest and most thorough method for grading wear debris for his budgetary limits. 7 Johnson, M. (2007), Oil Analysis: Past, Present & Future: Part II, TLT, 63(6), p. 35. WWW.STLE.ORG TRIBOLOGY & LUBRICATION TECHNOLOGY MAY 2011 7

conclusion There are common wear modes for most machines that produce wear debris that is too large to be identified by the most commonly used wear debris analysis tools. Coupling additional techniques to routine test slates and establishing automatic triggers to escalate testing into non-routine tests can overcome this sensitivity weakness. Tests can be divided into quantitative and qualitative methods, each with merits and drawbacks. A recommendation is provided that the practitioner could consider for decisions to layer in secondary and tertiary tests to complete the machine wear debris profile. Figure 8 Multi-Parameter Test Method Qualification Chart. (Courtesy of AMRRI) Mike Johnson, CLS, CMRP, MLT II, MLA III, is the principal consultant for Advanced Machine Reliability Resources, in Franklin, Tenn. You can reach him at mike. johnson@precisionlubrication.com. 8 MAY 2011 TRIBOLOGY & LUBRICATION TECHNOLOGY WWW.STLE.ORG