EXPLORE GEOMETRY AND SPACE

Similar documents
2013 COMMERCIAL PRODUCTS

Continuous Insulation Systems for Exterior Walls

An Introduction to Spray Foam Insulation

Spray Foam and the Building Codes

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

ICYNENE AND YOUR LEED PROJECTS USGBC LEED CREDIT OPPORTUNITIES FOR ICYNENE SPRAY FOAM INSULATION PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

TER No Use of Icynene Classic Plus Spray Polyurethane Foam (SPF) in Unvented Attics & Crawlspaces

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

ICC-ES Evaluation Report Reissued February 1, 2012 This report is subject to renewal February 1, 2013.

Meeting Code Requirements With Open Cell Foam. Paul Duffy, M.A.Sc., P.Eng. Vice President, Engineering Icynene Inc.

ICYNENE AND. CaGBC LEED Credit Opportunities For

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

2

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ENERGY EFFICIENCY COMMITTEE

Deer Ridge Consulting, Inc.

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Originally Issued: 2/12/2016 Revised: 07/28/2017 Valid Through: 2/28/2018

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER: DAP FOAM, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC. EVALUATION SUBJECT:

Design Professionals. We ll change the way you think about. Insulation and your Designs

Impact of NFPA 285 on Air Barrier Specification and Design

SECTION SPRAY FOAM INSULATION

ENERGY SAVINGS FOR LIFE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

Continuous Insulation and Air Barriers for High Performance Walls

15402 Vantage Parkway East, Suite 322 Houston, Texas

6747 Campobello Road Mississauga, Ontario, Canada

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Thermal Bridging in Residential Construction

BELOW GRADE ASSEMBLIES AND RIGID INSULATION

8/14/2015. Course Description. Course Objectives AIR, WATER, AND MOISTURE MANAGEMENT IN LIGHT COMMERCIAL BUILDING ENVELOPES

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

Intertek Research Report IRR-1011

BASIC VENTILATION REQUIREMENTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BAYER MATERIALSCIENCE, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ELASTOCHEM SPECIALTY CHEMICALS, INC.

SECTION SPRAY FOAM INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS REPORT HOLDER:

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION DIVISION: AIR BARRIERS REPORT HOLDER:

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

How to design innovative, integrated wall systems and enhance the exterior beauty of your building.

SECTION Blown Insulation THERMAL INSULATION

New Opportunities For Spray Polyurethane Foam

How-to: Commissioning Design Reviews for the Building Envelope

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SPRAY FOAM POLYMERS

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Building Enclosure Design Fundamentals, Components, and Assemblies

1.0 - PRODUCT DESCRIPTION

Insulated Composite Panels Designed for Brick Back-up

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Compliance for Continuous Insulation, Water Resistive Barriers & NFPA-285 What you need to Know

New Approaches to Energy Efficiency & Green Building. Who is Icynene Inc.? World-Wide Distribution. The Icynene Insulation System

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

Gold Bond BRAND Gypsum Sheathing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

7/25/2011. THERMAL BARRlERS AND IGNITION BARRIERS. What is a Thermal Barrier? Thermal Barrier Code

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Managing Condensation and Thermal Performance with Continuous Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THERMOSEAL LLC EVALUATION SUBJECT:

ESR-2600 Reissued February 1, 2011 This report is subject to re-examination in two years.

ResidentialComplete WALL SYSTEMS

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Inspection Fundamentals: Stucco & EIFS

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Parex Continuous Insulation (CI)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

THE IC Y N E N E AD V A N T A G E

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

Stayflex Systems FREQUENTLY ASKED QUESTIONS

White Paper. White Paper. Thermal and Ignition Barriers for Spray Foam Insulation. Prescriptive Thermal Barriers

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

SECTION GYPSUM BOARD

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Transcription:

COMMERCIAL PRODUCTS

EXPLORE GEOMETRY AND SPACE WITHOUT COMPROMISING BUILDING ENVELOPE PERFORMANCE Commercial design considerations come with very specific challenges that can t be addressed with just any type of insulation. Intensive use, acoustic considerations, HVAC, and aesthetic qualities barely scratch the surface. What about concealed condensation, corrosion, moisture build-up, and inefficient heating and cooling systems? Icynene insulation products let you design without compromise. Ideal for both wood or steel-framed construction, Icynene delivers a perfect fit for any shaped cavity. Unlike batts, Icynene conforms to unusual geometry and provides a continuous, protective barrier that significantly reduces air leakage, minimizes airborne moisture transfer, and optimizes energy efficiency. Icynene spray foam is sprayed into walls, ceilings, and floors, then expands 100 times its initial volume and cures within seconds. Icynene s Light Density products remain soft and flexible enough to move with the building substrate, leaving no gaps or seams that can compromise air-tightness. An insulation material that fails to control air leakage will be inadequate in resolving the associated health and economic concerns. Thermal performance, air quality, energy consumption, sound attenuation, and building durability are all negatively affected by uncontrolled air leakage. Integrating Icynene as part of a sustainable design strategy has proven to be an effective tool that allows design professionals to provide their clients with the advantage that comes from a controlled environment. ICYNENE is sprayed into walls, ceilings, and floors, then expands 100 times its initial volume and cures within seconds.

OPEN CELL OR CLOSED CELL SPRAY FOAM INSULATION? Architect and building owners selecting energy efficient spray foam insulation for their projects have a choice between specifying a 0.5 lb per cubic foot light density open cell product, or a 2.0 lb per cubic foot medium Light Density Open Cell: Spray in place insulation and air barrier Vapor permeable Breathes Will accommodate long term creep and seasonal movements Does not sustain mold Rejects bulk water Drains water through Typical R-Value of 3.6 per inch Water commonly used for blowing agent Suitable for interior applications only Key Advantages of Open Cell: Soft, flexible and highly adhesive texture allows the product to retain a tight air seal during the normal structural movement/shifting over the life time of the building Vapor permeable permits bi-directional drying of assemblies When applied to the underside of a roof deck, will allow for bulk water to pass through and visibly expose the location of an exterior roof leak Soft open cell structure allows for greater sound absorption versus closed cell structure Using a water based blowing agent instead of a synthetic blowing agent reduces the environmental impact Lower cost density closed cell product. Both product types are suitable for commercial construction. The decision to specify either one will make a difference in the finished cost, product performance, and application requirements. Medium Density Closed Cell: Spray in place insulation and air barrier Low vapor permeance Vapor barrier (class II VDR) Rigid design adds structural reinforcement Does not sustain mold Rejects bulk water (even submerged) Deflects water path Typical R-Value of 6.0 per inch Blowing agent increases R value Suitable for both interior and exterior applications Key Advantages of Closed Cell: Higher R-value per inch, easier to accommodate higher R requirement in narrow spaces or thinner wall capacity Hard, rigid texture provides increased wall racking strength (if necessary) Also suitable for exterior and below grade applications as it rejects bulk water Lower vapor permeance, can be a class II VDR Impact resistance ICYNENE.com

OPEN CELL ICYNENE HIGH PERFORMANCE 100% WATER BLOWN PRODUCT ICYNENE LD-C-50 CLASSIC Approved for commercial building types I, II, III, IV, and V construction Light density, open-cell structure R-Value = 3.7 per inch Original Icynene formulation of 25+ years Vapor permeable, support bi-directional drying of assemblies Soft, flexible composition maintains an air seal even after seasonal expansion/contraction of building assembly Suitable for interior cavity fill applications Lower cost compared to closed-cell products Lowest global warming potential (GWP of 1) Superior cold temperature adhesion to multiple substrates PROVEN PERFORMANCE THE LIGHT DENSITY LEADER Icynene LD-C-50 is the product that made the Icynene name synonymous with superior quality, open-celled, 0.5 lb., light density spray foam insulation. Icynene LD-C-50 has been used in thousands of residential and commercial projects for over 25 years and is the industry benchmark for quality and innovation by which all other light density insulation products should be judged. 100% WATER BLOWN TECHNOLOGY ICYNENE LD-C-50 foam insulation products are 100% water-blown meaning they use no synthetic blowing agents or ozone depleting substances. The reaction used to create these products generates Carbon Dioxide to expand the foam. Carbon Dioxide has the lowest Global Warming Potential (GWP of 1) 1 1 All measure of GWP are given to carbon dioxide, the most well-known gas with global warming potential, which has a GWP of 1.

CLOSED CELL ICYNENE HIGH PERFORMANCE CHEMICAL, NON-OZONE DEPLETING BLOWING AGENT PRODUCT ICYNENE MD-C-200 Approved for commercial building types I, II, III, IV, and V construction Medium density closed cell structure R-Value = 6.0 per inch Rigid composition contributes to added wall racking strength Air impermeable material resists convective heat and moisture flow Class II vapor retarder at 1.5" Rejects bulk water 96% closed cell content Suitable for both interior and exterior applications Summer and winter formulations for all Climate Zones and Altitudes Low odor ICYNENE.com

ICYNENE S COST-EFFECTIVE THERMAL BARRIER SOLUTION The International Building Code (2006 IBC) requires the installation of an approved thermal barrier over all foam plastics (including spray foam insulation) separating the foam insulation from the interior space of the building. The IBC specifically lists 1/2" gypsum wallboard as an acceptable thermal barrier material. However, most recently new technology has emerged for more cost effective thermal barrier solutions such as a spray applied intumescent coating. Icynene has tested and qualified an intumescent coating, DC-315 as an approved spray applied thermal barrier over our open-cell LD-C-50 and closed-cell MD-C-200. This provides architects, designers, and commercial building owners with a cost effective option for exposed applications such as acoustical ceiling plenums, exposed roof assemblies, and attics connected to habitable space. For immediate assistance on technical inquiries, contact Icynene at: 1-800-758-7325 ADDITIONAL EXTERIOR VENEER CLADDING OPTIONS: Icynene LD-C-50 and MD-C-200 pass NFPA 285 Fire Test Complies with 2006 IBC Chapter 2603.5 for installation in exterior walls of many types I, II, III, IV, and V multi-storey buildings U.S. COMMERCIAL FIRE TESTING NFPA 285 NFPA 286 ASTM E-119 PASS PASS PASS In addition to the brick veneer featured in Icynene's Type I and II code compliant exterior wall assembly pictured on the lower-left, ICYNENE LD-C-50 and MD-C-200 products may also be installed with many other claddings compliant with ASTM E-136 as detailed below: Minimum 4" thick block masonry Stucco over fiber cement board or 5/8" DensGlass 1 sheathing Glass reinforced concrete panels James Hardie 2 board siding panels Details of the exterior wall covering must be provided to the code official by the report holder, designer, or specifier with an engineering analysis demonstrating that: 1) The wall covering conforms to ASTM E-136 2) The addition of the wall covering to the assembly described in Icynene's current ICC-ES Evaluation report for LD-C-50 and MD-C-200 does not negatively affect conformance of the assembly with the requirements of IBC section 2603.5 1 DensGlass is a trademark owned by Georgia-Pacific Gypsum LLC. 2 James Hardie is a trademark owned by James Hardie Building Products, Inc.

ARCHITECTURAL RESOURCES NEW AIA CONTINUING EDUCATION PRESENTATION INTRODUCED For many years Icynene has worked closely with the AIA as an approved provider within their Continuing Education System (CES). Over the past decade, Icynene has completed over 2,700 live presentations to more than 32,000 architects throughout North America. Just recently we added a new addition to our AIA approved list of courses. The new course is titled: DESIGNING FOR THE FUTURE Understanding Light Density and Medium Density Open Cell and Closed Cell Spray Foam Insulation SOME KEY LEARNING OBJECTIVES FEATURED IN THE PRESENTATION INCLUDE: Why SPF Products are growing in popularity and replacing traditional insulation materials The differences between open and closed cell spray foam insulation products The fundamentals of heat transfer Structures for effective air sealing The importance of having the materials installed by a properly trained technician certified by the SPF manufacturer Learning Units: 1 HSW/SD credit NEW ARCHITECTURAL SAMPLE KITS NOW AVAILABLE FOR KEY CLIENT PRESENTATIONS Recognizing that architects often require attractive, professional collateral materials for critical product evaluation and various client meetings, Icynene recently introduced a new commercial sample presentation kit. For more information on this exciting new package, contact your local ICYNENE sales representative. ICYNENE.COM 1-800-758-7325

ICYNENE S CORPORATE SUSTAINABILITY PHILOSOPHY Icynene believes that being a good corporate neighbor and a responsible steward of the world s resources means providing innovate solutions that helps address issues such as energy consumption and global warming. As one of the foremost manufacturers of spray foam insulation for the North American construction market, Icynene is leading the insulation industry to a new level of sustainability through its commitment to environmentally-preferable, spray foam technology that provides superior energy efficiency. Visit ICYNENE.com for more information on point carrier opportunities with the U.S. Green Building Council (USGBC) LEED 1 program. Icynene is also dedicated to reducing its own environmental footprint and educating our employees on conservation issues, teaching them how to be greener, and directing them to additional environmental resources. The Icynene Go Green initiative is an all-inclusive environmentally friendly green program that allows all staff the opportunity to actively participate. We are proud to have our Company and products associated with sustainable groups and non-government organizations such as USGBC, Earth Craft House 2, Energy Star 3, Collaborative for High Performance Schools (CHPS) 4, ICC-SAVE 5 and more. ICYNENE Inc. 6747 Campobello Road Mississauga ON L5N 2L7 Canada 800-758-7325 ICYNENE.com 1 LEED is a trademark owned by the U.S. Green Building Council 2 Earth Craft House is trademark owned by the Greater Atlanta Home Builders Association, Inc 3 ENERGY STAR is a U.S. registered mark of the United States Environmental Protection Agency 4 Collaborative for High Performance Schools is a trademark owned by Collaborative for High Performance Schools, Inc. 5 ICC Save is a registered trademark owned by the International Code Council SL-320-01 SEPTEMBER 2011