Solar Cooling Technologies for Southern Climates - A System Comparison

Similar documents
Solar Cooling for Southern Climates, Double Effect Absorption Chillers with High Concentrating Collectors Versus Standard Single Effect Systems

Heat rejection systems for solar driven sorption systems

Simulation of Solar Thermal Cooling System for an Office Building in Indian Climates using Evacuated Tube Collector

SOLAR COOLING WITH SMALL SIZE CHILLER: STATE OF THE ART

International Journal of Refrigeration 2012, Pages , Volume 35, Issue 3

Control strategies study of a complete solar assisted air conditioning system in an office building using TRNSYS.

Experiences from design studies, simulation studies and installations

Simulation and economic analysis of solar cooling for building in tropical climate of Surabaya, Indonesia

Solar Thermal Application in Industry

Solar Air-Conditioning Systems in small - medium scale applications

Modeling and analyzing solar cooling systems in Polysun

ST-4 Polygeneration plant. Parc de l Alba Cerdanyola del Vallès

Analysis of Solar Thermal Cooling System Using TRANSOL

Customized Absorption Heat Pumps for Utilization of Low-Grade Heat Sources

The Path Towards Zero Energy District Cooling Plant in Qatar. Salah Nezar, LEED AP, QSAS GCP, Sustainability Director, QPM

Innovative Systems for Solar Air Conditioning of Buildings

SorTech package solution description

Performance evaluation of hybrid solar parabolic trough concentrator systems in Hong Kong

EVASOLK. Evaluation of Solar Cooling in Comparison to Reference Technologies

Content. State of the Art in Solar Cooling. Solar cooling technology developments. Market developments & barriers

New developed solar thermal systems for heating and cooling Budapest, 16 th April 2009 Tsekouras Panagiotis Mech. Engineer NTUA Centre for Renewable

Héctor Rubio Plana Gas Natural, SDG S.A. 18th. June 2009

A Review of Solar Driven Absorption Cooling with 1 Photovoltaic Thermal Systems 2

Master Level Thesis. Techno-economic Appraisal of Concentrating Solar Power Systems. European Solar Engineering School No.

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

Solar Power. Technical Aspects and Environmental Impacts. 6 th March 2011 Sustainable Energy Options (UAU212F) - University of Iceland

Figure 1: Uncovered and covered PVT collectors

Guidance page for practical work 1: modeling of a thermodynamic solar plant

Gas Natural, SDG S.A. 18th. June 2009

EFFICIENT SOLAR COOLING

Solar process heat for sustainable automobile manufacturing

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

Chromasun Micro-Concentrator

Financial Evaluation of Solar Powered Absorption Cooling System for Computer Laboratory

IEE Solar Combi + WP3 Virtual Case Studies

Providing free cooling from low temperature waste heat

Australian Solar Cooling Interest Group (ausscig) Conference DHW/COOLING HYBRID STRATEGY FOR SOLAR COOLING:

Simulation and Design of Solar Absorption Cooling System. Simulacija i projekt solarnog apsorpcijskog sustava hlađenja

ASSESSMENT AND DESIGN OF ROOFTOP SOLAR PV SYSTEM. Click to begin

In general, passive-solar components can be described by the U-value (heat loss coefficient) and

UNIT FOUR SOLAR COLLECTORS

New Generation of Solar thermal Cooling with Yazaki. Wei Zheng Yazaki Energy System Corporation Beijing Office

State of the art for solar thermal or PV cooling and refrigeration

Inventaire des installations de climatisation solaires en Europe Inventory of solar cooling installations in Europe

Solar cooling design: a case study

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Available online at ScienceDirect. Energy Procedia 48 (2014 )

EXECUTIVE SUMMARY: Best practices and lists of technologies to refurbish buildings & Proposed packages of measures

Solar Thermal Energy for Cooling Applications and Industrial Process Heat

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Product catalogue A25s. Solar Cooling systems

Identified technologies for the InfraSUN pilot plant

Product catalogue A25s. Solar Cooling systems

SOLAR COOLING FOR ENERGY SAVING. CAN WE AFFORD NOT TO USE THE HEAT OF THE SUN?

Introduction to Renewable Energy

Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller

Glazed photovoltaic-thermal component for building envelope structures

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Simulation Studies on Performance of Solar Cooling System in UAE Conditions

Overview CSP Technologies, Markets, Challenges

Innovative Solar thermal systems for heating and cooling

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

IEE Solar Combi + WP3 Virtual Case Studies

Green Star Design & As Built Submission Template

3rd International Conference Solar Air-Conditioning Palermo 2009

ANALYSIS AND MITIGATION OF THERMAL EFFECTS ON A LARGE FACADE-MOUNTED PV ARRAY

Keynote: Solar Cooling potential in the MENA Region

Funded by. EU GCC CLEAN ENERGY NETWORK II Join us: Contact us:

Energy Technology & Conservation. Week_05. Instructor: Mr. Adnan Qamar. Mechanical Engineering Department

EXPERIMENTATION AND MODELLING OF A SMALL-SCALE ADSORPTION COOLING SYSTEM IN TEMPERATE CLIMATE. July 22, 2013

Comfort Cooling Application Using Fixed Focus Solar Parabolic Dish Concentrator Integrated with Double Effect Vapor Absorption Machine

Solar Thermal Systems Status Technologies - Perspectives. Dr. Bernd Eikmeier Bremer Energie Institut

Energy Audit Summary Report Audit No. 21. Pharmaceutical Industry

Energy Resources. Assosciate Professor

Solar Thermal Systems- A reliable technology for Green Buildings

Australian Solar Cooling Interest Group (ausscig) Conference Financial analysis of solar cooling systems in Australia

Peer Reviewed 2014 Solar Research Conference

Reminder: Solar and Terrestrial Radiation

Passive Houses in South West Europe

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

energy Solar reflective surfaces

Simulation And Optimization of a Solar Absorption Cooling System Using Evacuated Tube Collectors

SOLAR ENERGY USED FOR HEATING AND COOLING SYSTEMS

Experimentation and simulation of a small-scale adsorption cooling system in temperate climate

ASI Glass. Integrated Architecture Powered by the Sun

Thermally Driven Cooling

Solar Absorption Aqua-Ammonia Absorption system simulation base on Climate of Malaysia

From Concept to Product

ENERGY EFFICIENT TECHNIQUES AND SIMULATION OF ENERGY CONSUMPTION FOR THE SHANGHAI ECOLOGICAL BUILDING

Solar Wing EVO. Trivelli Energia srl. Via 1 Maggio. 23B Bressana Bottarone (PV), Italy. Tel Fax

Long-term monitoring and smart heat pumps for nzeb

Over 3 decades, the company has helped customers to be competitive and earn community goodwill by :

Sustainable Energy Science and Engineering Center. Concentrating Collectors - Power Generation

Limits and potentials of office building climatisation with ambient air

ScienceDirect. Application of a novel, vacuum-insulated solar collector for heating and cooling

Solar heating and cooling solutions for buildings

Investigation of a Solar active glass facade

Active solar heating system with concrete plate heating analysed with dynamical thermal simulations

Solar-Assisted Space Heating of a Highly Insulated Energy Efficient House

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

Transcription:

Solar Cooling Technologies for Southern Climates - A System Comparison Dirk Pietruschka 1, Uli Jakob 2, Ursula Eicker 1 1 Centre of Applied Research Sustainable Energy Technology - zafh.net, Stuttgart University of Applied Sciences, Schellingstrasse 24, D-7174 Stuttgart, Germany, Phone +49 711 8926 2674, dirk.pietruschka@hft-stuttgart.de 2 Solem Consulting, Postfach 2127, D-7137 Weinstadt, Germany Phone +49 174 413921, uli.jakob@solem-consulting.com Abstract In the present paper different solar thermal cooling systems are compared to a PV driven and a net connected compression chiller in hot and dry southern climate. The cooling systems are considered to be applied to a planned innovative office building in Cairo, Egypt. A single effect absorption chiller with vacuum tube is analysed as well as a double and a triple effect absorption chiller with higher concentrating Fresnel. For the PV driven compression chiller system high efficient mono crystalline PV modules are considered together with a highly efficient compression chiller system with integrated direct dry het rejection. Dynamic system simulations with INSEL are used to analyse the performance of the different cooling systems. To compare the overall performance of the analysed solar cooling systems, the primary energy consumption required to cover the whole cooling load of the building and the resulting primary energy ratio are calculated for each system. 1. Introduction The overall efficiency of solar driven absorption cooling machines (ACM) is mainly influenced by the thermal COP of the absorption chiller and the electricity consumption caused by the heat rejection system, the chiller and all connected system pumps. Single effect absorption chillers reach only quite low thermal COPs which are typically in the region between.55 and.75. In consequence, large solar collector areas and large heat rejection systems are required to reach high solar fractions and to remove the waste heat. This often cause high electricity consumptions which reduces the primary energy efficiency of the systems [1]. However, the main advantage of single effect absorption and adsorption chillers is the relatively low driving temperature which varies between 65 C and 95 C. Such temperatures can be provided by efficient flat plate or vacuum tube. Double effect absorption chillers reach much higher thermal COPs of 1.3 and above but typically require much higher driving temperatures of around 18 C. To provide such high temperatures higher concentrating solar systems like parabolic trough or

linear Fresnel are required [2]. Due to decreasing PV module prices PV driven highly efficient compression chillers become more and more attractive as a competitive solar cooling technology. In the present paper a detailed simulation based case study of a solar cooling application for an office building project in Cairo Egypt is presented. Here, four different systems are regarded: Single effect, double effect and triple effect absorption chillers and a PV driven compression chiller. The single effect absorption chiller is considered to be purely solar driven. For the double and triple effect absorption chiller backup heating with a gas boiler / integrated gas burner is considered. In case of the PV driven compression chiller additional electricity is imported from the local grid if not sufficiently provided by the PV system. 2. Description of the Analysed Building and its Location The analysed office building is located in Cairo in Egypt and has a total useful floor area of 15 1 m² with a conditioned volume of 55 116 m³. It consists of a central core and three starlike adjacent fingers with four office floors each. Double glazed windows with sun protecting coating are considered for the fully glazed facades with an U-Value of 1.16 W/m²K and g-value of.265 with 3.8% framing fraction and an U- Value of the frames of 2.4 W/m²K. Additional shading is provided by a roof overhang of 2.5 m in the upper floors of the south, southeast and southwest facing facades. For all opaque building elements like external walls, roof and floors a insulation of 2 cm is considered resulting in U-values around.18 W/m². According to dynamic building simulations performed with TRNSYS the maximum cooling load of the building is about 8 kw (52 W/m²) and the annual cooling energy demand is 197 MWh/a (13 kwh/m²a). Due to the necessity of dehumidification in summer the temperature level of the cold water distribution system is 7 C/14 C. The local weather conditions used in the dynamic simulations are taken form METEONORM weather data base. 3. Analysed solar cooling systems The limiting factor for the size of the solar cooling systems is the available and usable roof area for the solar thermal or PV system, which is 2 m² only. For the system design several simulations were performed for single effect, double effect and triple effect absorption chillers. The single effect absorption chiller was combined with efficient vacuum tube (Jiangsu Sunrain TZ47/15-1U) with an optical efficiency of.65, a linear heat transfer coefficient of 1.585 W/m²K and a temperature dependent quadratic heat transfer coefficient of.2 W/m²K². The maximum possible collector size at horizontal orientation is 25 m² brut collector area which is equal to a collector aperture area of 135 m² (1.5 ). For the double effect

absorption chiller linear concentrating Fresnel of Industrial Solar are considered. The optical efficiency of the Fresnel is 62% with a linear heat transfer coefficient of.1 W/m²K and a temperature dependent quadratic heat transfer coefficient of.43 W/m²K². For the linear Fresnel the maximum collector aperture area is 132 m² (6 ; length 4 m; width 8 m). To evaluate the optimum system configuration the size of the hot water storage and the capacity of the absorption chillers were varied. For the comparison of single, double and triple effect absorption chillers the optimum system design found for each of the solar thermal cooling systems was selected. For the PV driven compression chiller the available and useful roof are of 2 m² allows the installation of 12 m² mono crystalline PV modules with an optimum inclination of 25 towards south. The following four system configurations are analysed: Case 1: Single effect ACM (LiBr) 422 kw (THERMAX, ProChill LT12C), 7 C/12.2 C cold water, wet cooling tower (29.4 C/36.6 C), vacuum tube collector field for hot water supply. 225 m² brut collector area, 135 m² collector aperture area, 3.3 kw electricity consumption solar pump, 2 m³ hot water storage and 1 m³ cold water storage Case 2: Double effect ACM (LiBr) 5 kw (Shuangliang 5 KW) 7 C/12 C cold water, wet cooling tower (37 C/42 C), linear concentrating Fresnel (Industrial Solar) for hot water supply. 2 5 m² brut collector area including spaces between the rows, 1 32 m² collector aperture area, 3.2 kw electricity consumption solar pump, 2 m³ pressurised hot water storage (max. 2 C) and 1 m³ cold water storage. Case 3: Triple effect ACM (LiBr) 563 kw vapour driven (25 C) (Kawasaki Sigma Ace CF1-1- 1), 7 C/15 C cold water, wet cooling tower (32 C/36.6 C), linear concentrating Fresnel (Industrial Solar) for water steam supply (max. 25 C at 3.9 MPa) 128 m² brut collector area including spaces between the rows, 88 m² Collector aperture area, 1.8 kw electricity consumption solar pump, no hot water storage and 1 m³ cold water storage. Case 4: Compression Chiller 795 kw (Quantum A9 3C12 with R-134a as refrigerant), 7 C/12 C cold water, with integrated direct dry heat rejection for refrigerant condensation (power given at 35 C ambient air temperature), the electrical COP is 2.9 at 1%, 3.9 at 75%, 4.9 at 5% and 6.5 at 25% cooling capacity. A 1 m³ cold water storage is considered PV modules 875 Aleo S17 modules of ALEO Solar GmbH with 18 W per module at maximum power point (I_SC = 8.42 A, U_OC =3.4 V). 25 Inclination towards south, 126 m² total module area, 156 kwpeak total installed power at maximum power point. Inverter: Sunny Central SC 15 of SMA, 15 kw nominal power, Umax,DC = 9 V; Imax,DC = 354 A (Grid connected without battery) For the thermal cooling systems additional cooling is considered to be provided by an efficient compression chiller with an average electrical COP of 2.8 including the electricity consumption of the compression chiller, of the dry heat rejection system and of all connected pumps. For heat rejection of the thermally driven LiBr chillers wet cooling towers are considered with frequency inverters for fan speed control at part load conditions. The single effect and triple effect absorption chillers are

combined with an AXIMA EWK 68/9 and the double effect chiller with an AXIMA EWK 45/9 cooling tower. Compared to the single effect absorption chiller, the required heat rejection energy is much lower for the triple effect chiller but due to the high mass flow rate in the absorber/condenser circuit the bigger cooling tower is required. 4. Results and Discussion The main simulation results found for the analysed solar cooling systems are shown in Figure 1 to Figure 3. The fraction of the thermally driven absorption chillers on the overall cooling energy demand of the building is shown in Figure 1 together with the solar system efficiency. The lowest absorption chiller fraction of 37% is reached for the single effect absorption chiller, since no backup heating is used in this case. This system reaches compared to the higher concentrating systems the highest overall solar thermal system efficiency of 4%. The much lower solar system efficiency of the systems with higher concentrating collector results mainly from the fact, that these can only use the direct solar radiation and not the diffuse part of it. In the annual average the direct beam radiation part is in Cairo only 6% of the total solar radiation. The system with the double effect absorption chiller and higher concentrating collector reach 91% ACM fraction on the cooling load, since only the peak loads above 5 kw need to be covered by the compression chiller. The triple effect absorption chiller reaches a higher maximum cooling power of 563 kw and is therefore able to cover 93% of the annual cooling load of the building. The solar heating energy and the additional heating energy provided to the absorption chillers is shown in Figure 2 together with the average thermal COP of the chillers which are.7 for the single effect, 1.31 for the double effect and 1.83 for the triple effect chiller. Due to the higher thermal COP the double and triple effect chillers require much lower heating energy than the single effect system. Figure 3 shows the primary energy consumption of the four analysed solar cooling systems compared to the primary energy consumption of the reference system with efficient compression chiller. The resulting average primary energy ratio of all analysed systems is also shown in this graph. From this graph it becomes clearly obvious, that the primary energy ratio of the single effect absorption chiller with vacuum tube and additional cooling is with 1.43 only slightly lower than that the double effect absorption chiller with Fresnel, additional heating and additional cooling which reaches a value of 1.5. The overall best energetic performance is reached for the triple effect absorption chiller which reaches a primary energy ratio of 1.6 which is 12 % higher than in case of the single effect system.

1% 5% ACM fraction / % 9% 8% 7% 6% 5% 4% 3% 2% 4% 37% 91% 31% 93% 27% 45% 4% 35% 3% 25% 2% 15% 1% Solar system efficiency / % 1% 5% % Single effect ACM + vacuum tube Double effect ACM + Fresnel Triple effect ACM + Fresnel % ACM fraction Solar system efficiency Figure 1: Fraction of the ACM on the cooling load and solar system efficiency Heating energy consumption / MWh a -1 14 12 1 8 6 4 2 15,7 577 1,31 792 1,83 534 469 2 1,8 1,6 1,4 1,2 1,8,6,4,2 COP th / - Single effect ACM + vacuum Double effect ACM + Fresnel Triple effect ACM + Fresnel tube Qh_solar Qh_additional COPth Figure 2: Solar heating, additional heating and average thermal COP If the local electricity grid is considered as ideal storage the PER of the PV driven compression chiller is with 1.59 only slightly lower than the best thermal cooling system (33% PV contribution). If only the produced electricity is considered, which can be directly used by the chiller (22% PV contribution), the PER decreases to 1.37 which is even worse than the single effect absorption cooling system. Compared to an efficient standard compression cooling system only fed by the local grid, all analysed solar cooling systems reach significantly higher primary energy ratios of

+38% in case of the single effect absorption chiller up to +54% in case of the triple effect chiller with Fresnel. This highlights the main advantage of efficient designed and controlled solar cooling systems. 2 2 Primary energy consumption / MWh a -1 18 16 14 12 1 8 6 4 2 1,43 1194 183 Single effect ACM + vacuum tube 1,5 176 128 692 64 443 462 Double effect ACM + Fresnel 1,6 1,59 Triple effect ACM + Fresnel 124 CCM with PV, grid as ideal storage 1,37 1443 CCM with PV, electricity directly used 1,4 19 Reference system with compression chiller only 1,8 1,6 1,4 1,2 1,8,6,4,2 Primary energy ratio PER / - Electricity Additional heating Additional cooling PER Figure 3: Primary energy consumption and average primary energy ratio (PER) 5. Conclusions The results found in this paper clearly demonstrated that double effect absorption chillers with backup heating (1st choice) and backup cooling (2nd choice) are from the primary energy point of few not necessarily better than single effect absorption chillers with backup cooling only. The overall best performance with a primary energy ratio of 1.6 was reached for a triple effect chiller with backup heating (1st choice) and backup cooling (2nd choice). The analysed highly efficient PV driven compression chiller reaches a comparable primary energy ratio, if the local electricity grid is considered as ideal storage. Otherwise, the primary energy ratio of this system is lower than that of the analysed thermal cooling systems. However, it could be shown that all analysed solar cooling systems reach significantly higher primary energy efficiencies than standard systems with compression chillers only. Further analyses will focus on the comparison of the economic performance of all analysed systems. References: [1] Albers, J., Kemmer, H., Ziegler, F. Solar driven absorption chiller controlled by hot and cooling water temperature,3rd International Conference Solar Air-Conditioning, 3th September 2nd October, Palermo, Sicily, Italy, proceedings pp 338-343, 29 [2] Rubio, H., Solar cooling systems and natural gas; experiences and results, in proceedings of the 7 th European Forum Gas, Madrid, Spain, 29