Separator, suitable tape between the braid and outer sheath

Similar documents
YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC

OFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable

Copper Cable Company Limited

Tele-Fonika Cable Americas

H-FLEX CABLES 10/2017

Construction guideline

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

SafeX110 Single Core Flexible Tinned Copper Cable

8 139 Foreword c) Technical Hydraulic oil Hydraulic/gear oil Accepted. Gear oil added throughout the standard

Confirmation of Product Type Approval

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Comparison of BS 5308, PAS 5308 and BS EN

Armoured Instrumentation Cables to BS7917

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

INSTRUMENTATION, CONTROL AND THERMOCOUPLE CABLES

Instrumentation Cables

Instrumentation and Thermocouple Cables

Instrumentation and Thermocouple Cables

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152

Single core conductor BETAtherm 145

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

Confirmation of Product Type Approval

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

SPECIFICATION FOR FRLS POWER CABLES

M-FLEX CONTROL CABLES

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

DATA SHEET Single Core 2HR Fire Rated Cable

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

MATERIAL STANDARD FOR CABLES AND WIRES

Compact Module. Enhanced Category 5 FTP Cabling System

Data sheet chainflex CFSPECIAL.182

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

Rail Wire Guide. Harnessing and Electro-Mechanical Solutions for Demanding, Harsh Environment Applications... LFH FREE

FieldLink for PROFIBUS Applications

Electric cables. CRANES APPENDIX

Low Smoke Halogen Free cables

Halogen-free data transmission cable with colour code acc. to DIN resistant to a wide range of chemical media

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

Cables de Comunicaciones Zaragoza. CW1601 Approval application.

26/35kV Copper XLPE Insulation Electric Cable

7. EXTENSION LEADS AND COMPENSATING CABLE

Caledonian Cables Ltd

Flexible Cables for Cranes and other industrial applications

INTERNATIONAL STANDARD

Application (easy to strip) ES cable for permanent installation. and mechanical stress (easy to strip) 1x2x22AWG 1

The Company by Peter Bröckskes sen. an independent, middle sized company

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

PRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems


*** Supercedes: BECO E and COM , , & ***

EXPLOSION-PROOF CABLE GLAND - Type ICG 623 Manual

Content HYBRID AND SPECIAL CABLES G 2 NEW NEW NEW NEW. page. Applications... G/3. Construction examples of special cables

List Price w.e.f. 24th July, 2018

S P Y C F A - S P Y C. N o m i n a l o v e r a l l d i a m e t e r

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America

List Price w.e.f. 02nd January, 2018

RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015

Data sheet chainflex CF887

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

RBT Cable for Industrial machinery

Cables for Railway Signalling Applications General Requirements

INDUSTRY. Welding Cables. Highly flexible, resistant and robust.

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

WIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES

according to UL AWM 758, Style and based on EN resp. VDE

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

Engineering Data for Copper and Aluminum Conductor Electrical Cables

ENERGYFLEX, Guarantees long-term photovoltaic performance

INTERNATIONAL STANDARD

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

SECTION INSULATED WIRE AND CABLE

Cable Jointing Manual. Jointing Procedures. Module 18. Concentric Cables


Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Pt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.

U.V resistance UL Sunlight Resistance. Flame retardant IEC

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

SUBMERSIBLE. Electric cables

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)

Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

PURENET-U (Part No.: U RXX2, U PXX2)

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

SECTION ELECTRICAL CABLE. 1. Trench excavation, backfill, and compaction; Section

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting

THE PATHWAY TO POWER HIGH AND EXTRA HIGH VOLTAGE CABLES

Transcription:

Picture is for information only. Applicable standards: NEK TS 606 Code S1/S5, IEC 60092-376- Design guidelines IEC 60228 conductor IEC 60092-351 Insulating material, IEC 60092-359 Sheathing materials IEC 60332-1, IEC 60332-3-22 Flame retardant IEC 60754-1,2 Halogen free, IEC 61034-1,2 Low Smoke CONSTRUCTION Code Letter Conductors Tinned annealed circular stranded copper according to IEC 60228 class 2 Insulation R EP rubber thermosetting compound,iec 60092-351 (EPR) Pair, Triple, Quad twisting Lay up/ Shielding Color coded cores twisted together. Pairs/ Triples are screened by copper backed polyester tape with tinned copper drain wire.each pair/ triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/ triples. Pairs/ triples are identified by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with polyester tape. Inner covering F Flame retardand and halogen free thermosetting compound Armour/screen O Poliester or Cu/PET tape & Tinned annealed copper wire braid For EMC cable Separator Cu/PET tape under the braid Separator, suitable tape between the braid and outer Outer U Flame retardand, halogen free and mud resistant thermosetting compound SHF2 (IEC 60092-359) Colour of outer Grey or Blue Standard marking E.g. TF KABLE 3 RFOU (i) 250V S1/S5 2 PAIR 0,75mm 2 IEC 60332-3-22 IEC 60092-376 1

FEATURES Maximum conductor operating temperature: +90 C Maximum conductor temperature during short circuit: +250 o C Lowest ambient temperature for fixed installation: -40 C Lowest installation temperature: -15 C Minimum bending radius: 6 D D overall diameter of cable Flame retardant IEC 60332-3-22 (Category A) Smoke emission: IEC 61034-2 Corrosive gas emission: IEC 60754-1 Oil resistance: IEC 60092-359 SHF2, IRM 902 (100⁰C/24h) Mud resistance: NEK 606 (SHF MUD, SHF2) APPLICATIONS Fixed installation for instrumentation,communication, control and alarm system in both EX -and safe areas Meets the MUD resistance requirement in NEK TS 606 Marine For fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications requiring screened cable for EMC Other industrial applications APPROVAL DNV GL Certificate No: E14151 ABS 15GD1364505- PDA Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request 2

Size Class of conductor Insulation Thickness inner Diameter of braid wire 3 outer overall diameter net weight of cable N x 2 x mm2 Inch Inch Inch Inch Inch Lb/1000ft 1x2x0,75 2 0,024 0,043 0,008 0,043 0,406 99,441 2x2x0,75 2 0,024 0,043 0,008 0,047 0,567 166,631 4x2x0,75 2 0,024 0,043 0,012 0,051 0,614 238,525 8x2x0,75 2 0,024 0,043 0,012 0,059 0,756 372,233 12x2x0,75 2 0,024 0,055 0,012 0,063 0,902 520,723 16x2x0,75 2 0,024 0,075 0,012 0,067 1,043 688,026 19x2x0,75 2 0,024 0,075 0,012 0,067 1,106 774,701 24x2x0,75 2 0,024 0,083 0,012 0,075 1,232 954,770 1x3x0,75 2 0,024 0,043 0,008 0,043 0,417 108,848 2x3x0,75 2 0,024 0,043 0,012 0,051 0,598 206,945 4x3x0,75 2 0,024 0,043 0,012 0,055 0,669 288,245 8x3x0,75 2 0,024 0,043 0,012 0,063 0,854 468,986 12x3x0,75 2 0,024 0,055 0,012 0,067 1,004 653,087 16x3x0,75 2 0,024 0,083 0,012 0,071 1,173 880,189 19x3x0,75 2 0,024 0,083 0,012 0,071 1,248 995,756 24x3x0,75 2 0,024 0,098 0,016 0,079 1,421 1249,062 1x2x1,5 2 0,028 0,043 0,008 0,043 0,457 125,645 2x2x1,5 2 0,028 0,043 0,012 0,051 0,693 258,010 4x2x1,5 2 0,028 0,043 0,012 0,055 0,787 366,857 8x2x1,5 2 0,028 0,043 0,012 0,067 0,909 543,567 12x2x1,5 2 0,028 0,055 0,012 0,071 1,094 776,716 16x2x1,5 2 0,028 0,075 0,012 0,075 1,264 1023,976 19x2x1,5 2 0,028 0,075 0,012 0,075 1,346 1163,731 24x2x1,5 2 0,028 0,091 0,016 0,087 1,539 1536,635 1x3x1,5 2 0,028 0,043 0,008 0,043 0,480 145,130 2x3x1,5 2 0,028 0,043 0,012 0,055 0,709 287,573 4x3x1,5 2 0,028 0,043 0,012 0,059 0,795 417,922 8x3x1,5 2 0,028 0,043 0,012 0,071 1,035 703,479 12x3x1,5 2 0,028 0,055 0,012 0,075 1,224 999,787 16x3x1,5 2 0,028 0,091 0,016 0,079 1,461 1363,957 24x3x1,5 2 0,028 0,098 0,016 0,091 1,736 2004,278

1x2x2,5 2 0,028 0,043 0,008 0,043 0,488 149,162 2x2x2,5 2 0,028 0,043 0,012 0,055 0,575 247,259 4x2x2,5 2 0,028 0,043 0,012 0,059 0,807 428,000 Without approvals Size Class of conductor Insulation Thickness inner Diameter of braid wire outer overall diameter net weight of cable N x X x mm2 Inch Inch Inch Inch Inch Lb/1000ft 4x2x2,5 2 0,028 0,043 0,012 0,059 0,862 454,876 8x2x2,5 2 0,028 0,043 0,012 0,067 1,177 784,107 16x2x2,5 2 0,028 0,043 0,012 0,075 1,465 1322,971 24x2x2,5 2 0,028 0,047 0,016 0,087 1,839 1994,199 1x3x2,5 2 0,028 0,039 0,008 0,047 0,512 178,054 4x3x2,5 2 0,028 0,043 0,012 0,059 0,945 564,396 16x3x2,5 2 0,028 0,047 0,016 0,083 1,661 1817,490 1x4x2,5 2 0,028 0,039 0,008 0,047 0,547 207,617 4x3x1 2 0,024 0,039 0,012 0,055 0,886 426,657 4

All the information contained in this document - including tables and diagrams - is given in good faith and believed to be correct at the time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time. 5