ISO INTERNATIONAL STANDARD. Caps made of aluminium-plastics combinations for infusion bottles and injection vials Requirements and test methods

Similar documents
ISO 8872 INTERNATIONAL STANDARD. Aluminium caps for transfusion, infusion and injection bottles General requirements and test methods

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Injection containers and accessories Part 6: Caps made of aluminium-plastics combinations for injection vials

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Self-adhesive hanging devices for infusion bottles and injection vials Requirements and test methods

ISO INTERNATIONAL STANDARD. Infusion equipment for medical use Part 2: Closures for infusion bottles

ISO INTERNATIONAL STANDARD. Infusion equipment for medical use Part 2: Closures for infusion bottles

ISO INTERNATIONAL STANDARD. Infusion equipment for medical use Part 2: Closures for infusion bottles

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 5: Chemical loads

ISO INTERNATIONAL STANDARD. Welding coordination Tasks and responsibilities. Coordination en soudage Tâches et responsabilités

ISO INTERNATIONAL STANDARD. Metallic materials Tensile testing Part 2: Method of test at elevated temperature

ISO INTERNATIONAL STANDARD. Paper and board Testing of cores Part 9: Determination of flat crush resistance

ISO INTERNATIONAL STANDARD. Road construction and maintenance equipment Asphalt mixing plants Terminology and commercial specifications

ISO 4587 INTERNATIONAL STANDARD. Adhesives Determination of tensile lap-shear strength of rigid-to-rigid bonded assemblies

ISO INTERNATIONAL STANDARD. Machine-tools safety Safety requirements for the design and construction of work holding chucks

ISO INTERNATIONAL STANDARD. Compressed air Part 1: Contaminants and purity classes. Air comprimé Partie 1: Polluants et classes de pureté

ISO INTERNATIONAL STANDARD. Rigid cellular plastics Spray-applied polyurethane foam for thermal insulation Part 3: Test methods

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 3: Calibration of reference blocks

ISO 9597 INTERNATIONAL STANDARD. Cement Test methods Determination of setting time and soundness

ISO INTERNATIONAL STANDARD. Earth-moving machinery Anti-theft systems Classification and performance

ISO 2740 INTERNATIONAL STANDARD. Sintered metal materials, excluding hardmetals Tensile test pieces

ISO INTERNATIONAL STANDARD. Plastics Methyl methacrylateacrylonitrile-butadiene-styrene

ISO INTERNATIONAL STANDARD. Road construction and maintenance equipment Asphalt mixing plants Terminology and commercial specifications

ISO 8340 INTERNATIONAL STANDARD. Building construction Sealants Determination of tensile properties at maintained extension

ISO INTERNATIONAL STANDARD. Fibre-reinforced plastics Methods of producing test plates Part 9: Moulding of GMT/STC

ISO 3779 INTERNATIONAL STANDARD. Road vehicles Vehicle identification number (VIN) Content and structure

ISO 8339 INTERNATIONAL STANDARD. Building construction Sealants Determination of tensile properties (Extension to break)

ISO 5893 INTERNATIONAL STANDARD. Rubber and plastics test equipment Tensile, flexural and compression types (constant rate of traverse) Specification

ISO INTERNATIONAL STANDARD. Quality management systems Guidelines for configuration management

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Equipment for crop protection Induction hoppers Part 2: General requirements and performance limits

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Plastic containers for intravenous injections. Récipients en plastique pour injections intraveineuses

ISO 638 INTERNATIONAL STANDARD. Paper, board and pulps Determination of dry matter content Oven-drying method

ISO INTERNATIONAL STANDARD. Corrosion of metals and alloys Stress corrosion testing Part 7: Method for slow strain rate testing

ISO 75-3 INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Compressed air Part 7: Test method for viable microbiological contaminant content

ISO 1217 INTERNATIONAL STANDARD. Displacement compressors Acceptance tests. Compresseurs volumétriques Essais de réception. Fourth edition

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

ISO INTERNATIONAL STANDARD. Metallic materials Sheet and strip Determination of plastic strain ratio

ISO INTERNATIONAL STANDARD. Fibre-reinforced plastics Determination of fatigue properties under cyclic loading conditions

ISO 7132 INTERNATIONAL STANDARD. Earth-moving machinery Dumpers Terminology and commercial specifications

ISO INTERNATIONAL STANDARD. Plastics Decorative solid surfacing materials Part 1: Classification and specifications

ISO 835 INTERNATIONAL STANDARD. Laboratory glassware Graduated pipettes. Verrerie de laboratoire Pipettes graduées. First edition

ISO INTERNATIONAL STANDARD. Metallic powders Determination of apparent density Part 1: Funnel method

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 1: Test method

ISO 4986 INTERNATIONAL STANDARD. Steel castings Magnetic particle inspection. Pièces moulées en acier Contrôle par magnétoscopie

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Earth-moving machinery Operator enclosure environment Part 2: Air filter element test method

ISO 4987 INTERNATIONAL STANDARD. Steel castings Liquid penetrant inspection. Pièces moulées en acier Contrôle par ressuage. Second edition

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Polyethylene of raised temperature resistance (PE-RT) pipes Effect of time and temperature on the expected strength

ISO 648 INTERNATIONAL STANDARD. Laboratory glassware Single-volume pipettes. Verrerie de laboratoire Pipettes à un volume. Second edition

ISO INTERNATIONAL STANDARD. Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs

ISO INTERNATIONAL STANDARD. Paper and board Determination of tensile properties Part 2: Constant rate of elongation method (20 mm/min)

ISO INTERNATIONAL STANDARD. Packaging Transport packaging for dangerous goods Recycled plastics material

ISO INTERNATIONAL STANDARD. Building construction Jointing products Specifications for test substrates

ISO INTERNATIONAL STANDARD. Earth-moving machinery Determination of average ground contact pressure for crawler machines

ISO 8307 INTERNATIONAL STANDARD. Flexible cellular polymeric materials Determination of resilience by ball rebound

ISO 3369 INTERNATIONAL STANDARD. Impermeable sintered metal materials and hardmetals Determination of density

ISO INTERNATIONAL STANDARD. Rubber compounding ingredients Process oils Determination of glass transition temperature by DSC

ISO INTERNATIONAL STANDARD. Metallic materials Tensile testing Part 2: Method of test at elevated temperature

ISO INTERNATIONAL STANDARD. Cutting tools Designation of high-speed steel groups. Outils coupants Désignation des groupes d'aciers rapides

ISO INTERNATIONAL STANDARD. Office furniture Office work chairs Test methods for the determination of stability, strength and durability

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Industrial trucks Specifications and test methods for operator restraint systems Part 1: Lap-type seat belts

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Elastomeric seismic-protection isolators Part 2: Applications for bridges Specifications

ISO INTERNATIONAL STANDARD. Diesel engines NOx reduction agent AUS 32 Part 4: Refilling interface

ISO 5922 INTERNATIONAL STANDARD. Malleable cast iron. Fonte malléable. Second edition Reference number ISO 5922:2005(E)

ISO INTERNATIONAL STANDARD. Pallets for materials handling Quality of assembly of new wooden pallets

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Quality requirements for fusion welding of metallic materials Part 2: Comprehensive quality requirements

ISO INTERNATIONAL STANDARD. Water quality Measurement of gross alpha and gross beta activity in nonsaline water Thin source deposit method

ISO INTERNATIONAL STANDARD. Compressed air Part 6: Test methods for gaseous contaminant content

ISO 2177 INTERNATIONAL STANDARD. Metallic coatings Measurement of coating thickness Coulometric method by anodic dissolution

ISO INTERNATIONAL STANDARD. Wood-based panels Determination of modulus of elasticity in bending and of bending strength

ISO INTERNATIONAL STANDARD. Road vehicles Electrical and electronic equipment for a supply voltage of 42 V Electrical loads

Sýnishorn ISO 9004 INTERNATIONAL STANDARD. Managing for the sustained success of an organization A quality management approach

ISO INTERNATIONAL STANDARD. Copper, lead, and zinc sulfide concentrates Determination of transportable moisture limits Flow-table method

ISO INTERNATIONAL STANDARD. Meat and meat products Enumeration of presumptive Pseudomonas spp.

ISO INTERNATIONAL STANDARD. Testing of concrete Part 4: Strength of hardened concrete. Essais du béton Partie 4: Résistance du béton durci

ISO INTERNATIONAL STANDARD. Passenger cars Test track for a severe lane-change manoeuvre Part 2: Obstacle avoidance

ISO 7975 INTERNATIONAL STANDARD. Passenger cars Braking in a turn Open-loop test method

ISO 283 INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Space systems Programme management Non-conformance control system

ISO INTERNATIONAL STANDARD. Industrial trucks Verification of stability Part 14: Rough-terrain variable-reach trucks

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Quality management Guidelines for training. Management de la qualité Lignes directrices pour la formation

ISO 4986 INTERNATIONAL STANDARD. Steel castings Magnetic particle inspection. Pièces moulées en acier Contrôle par magnétoscopie

ISO INTERNATIONAL STANDARD. Water quality Determination of sulfates Method by continuous flow analysis (CFA)

ISO INTERNATIONAL STANDARD. Textiles Test methods for nonwovens Part 15: Determination of air permeability

Transcription:

INTERNATIONAL STANDARD ISO 10985 Third edition 2009-02-15 Caps made of aluminium-plastics combinations for infusion bottles and injection vials Requirements and test methods Capsules en combinaison aluminium-plastique pour flacons de perfusion et d'injection Spécifications et méthodes d'essai Reference number ISO 10985:2009(E) ISO 2009

PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2009 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyright@iso.org Web www.iso.org Published in Switzerland ii ISO 2009 All rights reserved

Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 10985 was prepared by Technical Committee ISO/TC 76, Transfusion, infusion and injection equipment for medical and pharmaceutical use. This third edition cancels and replaces the second edition (ISO 10985:1999) Clause 2 of which has been updated. ISO 2009 All rights reserved iii

Introduction The materials from which injection and infusion containers (including elastomeric closures) are made are suitable primary packaging materials for storing injectable products and infusion solutions until they are administered. However, in this International Standard, caps are not considered as primary packaging materials in direct contact with pharmaceutical preparations. iv ISO 2009 All rights reserved

INTERNATIONAL STANDARD ISO 10985:2009(E) Caps made of aluminium-plastics combinations for infusion bottles and injection vials Requirements and test methods 1 Scope This International Standard specifies general requirements and test methods for caps made of aluminiumplastics combinations in accordance with ISO 8536-7 or ISO 8362-6 intended for use respectively on infusion bottles as specified in ISO 8536-1 and/or injection bottles as specified in ISO 8362-1 and ISO 8362-4. The purpose of this International Standard is to specify caps that provide: a) guarantee of originality of the closure up to the point of administration; b) compression of the sealing element (rubber closure) on to the sealing surfaces of the infusion and/or injection bottles; c) protection of the sealing element against soiling and mechanical damage; d) simple and injury-free opening of the closure in order to expose the penetration area of the rubber closure and/or to permit total removal of the cap. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 7500-1, Metallic materials Verification of static uniaxial testing machines Part 1: Tensile/compression testing machines Verification and calibration of the force-measuring system ISO 8362-1, Injection containers and accessories Part 1: Injection vials made of glass tubing ISO 8362-4, Injection containers and accessories Part 4: Injection vials made of moulded glass ISO 8362-6, Injection containers for injectables and accessories Part 6: Caps made of aluminium-plastics combinations for injection vials ISO 8536-1, Infusion equipment for medical use Part 1: Infusion glass bottles ISO 8536-7, Infusion equipment for medical use Part 7: Caps made of aluminium-plastics combinations for infusion bottles ISO 8872:2003, Aluminium caps for transfusion, infusion and injection bottles General requirements and test methods ISO 2009 All rights reserved 1